More Structural Information with MSn

LTQ XL™

Linear Ion TrapMass Spectrometer

Part of Thermo Fisher Scientific

m a s s s p e c t r o m e t r y

SUPERIOR ION TRAP TECHNOLOGY

2

From the leader in Ion Trap Mass

Spectrometry, the LTQ XL Linear

Ion Trap delivers ultimate sensitivity

at breakthrough speed.

MetaboliteIdentification:

• Superior MSn spectral quality and full-scan acquisition

• Structural information on low level metabolites without knowingMRM transitions

• Data Dependent and Dynamic Exclusion™ acquisition for maximuminformation in complex samples

DiscoveryQuantitation:

Forensic and Clinical Analysis:

Proteomics:

• Excellent ion statistics for robust quantitation

• Optimum efficiency with Normalized Collision Energy™

• Simultaneous identification and quantitation for the regulatedlaboratory environment

• Outstanding robustness for reliable quantitation in complex matrices

• Simultaneous quantitation and confirmation in both positive andnegative ionization modes

• Ease of use for the production laboratory

• Maximum protein coverage resulting from superior cycle timesand sensitivity

• Automated MSn triggered Data Dependent™ neutral loss scan

• Flexibility of ionization modes, inlets, and chromatographic solutions

3

With the Accela™ High Speed LC System,the LTQ XL is the perfect tool for highthroughout applications.

Using multiple dissolution techniques, includingPulsed-Q Dissociation (PQD) and Electron

Transfer Dissociation (ETD), the LTQ XLgenerates extensive structural information

for the most demanding proteomics samples.

The LTQ XL Linear Ion Trap–Technology You Can Trust

METABOLITE IDENTIFICATION

AND CONFIRMATION

Metabolic studies are performedboth in vivo and in vitro necessitatingthe analysis of target compounds incomplex matrices. These biologicalmatrices contain the parent drug,all of its metabolites in a wide rangeof concentrations, and additionalendogenous metabolic materials.Furthermore, it is not pos sible topredict, in advance, all of themetabolites for a potentially newdrug compound.

Intelligent precursor ion selectionAutomated Data Dependent MSn

acquisition gives you information onnot only the predicted metabolites(parent list), but also on the unpre-dicted metabolites. In addition,classes of metabolites can bedetected using the automated DataDependent Constant Neutral Loss(CNL) triggered MS3 feature. Dataanalysis can be facilitated usingMetWorks™ and Mass Frontier™ soft -ware that enhances the screeningand characterization of metabolitesin complex matrices.

MetaboliteIdentification

• Analog signal-triggeredData Dependent MSn

acquisitions

• Constant Neutral LossData Dependent MSn

acquisitions

• MetWorks software

• Mass Frontier software

Automatically find all the metabolites the first

time, even the ones that you didn’t predict...

RT: 0.00 - 4.00RT: 0.00 - 4.00100

90

80

70

60

50

40

30

20

10

00.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

Rela

tive

Abun

danc

e

Time (min)

Reconstructed ion chromatograms for 13 identified drugsand metabolites in less than three minutes.

Simultaneous Metabolite Identificationand Quantitation for Metabolic Stability

Quantitation for metabolic stability

Qualitative and quantitative information in a single run

Data Dependent MSn metabolite identification

100806040200

100806040200

100806040200

195.22

146.00

91.07117.03

146.01

196.11

224.03252.08

263.29

196.07224.08

264.69

252.20

333.38 386.20 432.13463.51

Rela

tive

Abun

danc

e

252.30278.75

323.52398.32

423.40

463.23

465.27

466.26521.00

MS2 m/z 463

MS3 m/z 252

Full Scan MS

Trace using full-scan data points for quantitation

The LC/MSn raw data trace

O

OO

N

N

O

O N

Cl

O

N

C l

NNCH3

O

NO

N

CH3

CH3

OH

Cl

NCH3

O

O

CH3

O

O

N+

CH3

O

O

NCH3

Warfarin

Bifonazole

Ketoconazole

Loperamide

Nicardipine

Quan and ID(LC/MSn)

98%

83%

38%

17%

1%

HO

H3C

4

Increase inCoverage

CID with CIDand ETD and ETD

CID ETD Combined Combined

Ovalbumin 137 129 184 15%Albumin 239 248 345 18%

ELECTRON TRANSFER DISSOCIATION (ETD)

FOR PROTEOMICS AND BIOMARKER

APPLICATIONS

5

Available for the LTQ and LTQ XLmass spectrometers, ETD offersECD-like fragmentation in a linearion trap, producing abundant peptidefragmentation while preserving labile

PTMs, such as phosphorylation. ETD,combined with the high ion storagecapacity of Thermo Scientific linearion traps, creates a powerful new toolfor protein and peptide analysis.

ETD Makes the LTQ XLEven More Powerfulfor Proteomics

• Complementary with CID–Improves protein coverage

• Preserves labile PTMs,simplifying their analysis

• Automated CID and ETDin a single injection

ETD ion/ion chemistry. The LTQ XL ion trap isthe ideally suited device to exploit this technique.

200 400 600 800 1000 1200 1400m/z

0

5

10

15

20

25

30

35

40

45

50

55

60

65

70

75

80

85

90

95

100

Rel

ativ

e A

bund

ance

713.82

1427.45

1410.45

890.36

705.27

537.18

1268.36

1368.451004.36

159.09 1070.18357.18 684.36423.18242.18

527.27 1185.09900.27775.36428.27

674.27260.09

155.09630.27 797.45

C1

Z1C2

Z2

C3 Z3

C4 C6

Z4

Z5C7

Z6

C5

C8

Z7 Z8

C9

Z9

Z10

C11

Z11C10

ETD MS/MS spectrum of VIP 1-12 m/z 476.3 (3+) showing rich production of c and z ion series

40 fmol

100 fmol OVALBUMIN (P01012):

MGSIGAASMEFCFDVFKELKVHHANENIFYCPIAIMSALAMVYLGAKDSTRTQINKVVRFDKLPGFGDSIEAQCGTSVNVHSSLRDILNQITKPNDVYSFSLASRLYAEERYPILPEYLQCVKELYRGGLEPINFQTAADQARELINSWVESQTNGIIRNVLQPSSVDSQTAMVLVNAIVFKGLWEKAFKDEDTQAMPFRVTEQESKPVQMMYQIGLFRVASMASEKMKILELPFASGTMSMLVLLPDEVSGLEQLESIINFEKLTEWTSSNVMEERKIKVYLPRMKMEEKYNLTSVLMAMGITDVFSSSANLSGISSAESLKISQAVHAAHAEINEAGREVVGSAEAGVDAASVSEEFRADHPFLFCIKHIATNAVLFFGRCVSP

ALBUMIN (P02769):

MKWVTFISLLLLFSSAYSRGVFRRDTHKSEIAHRFKDLGEEQFKGLVLIAFSQYLQQCPFDEHVKLVNELTEFAKTCVADESHAGCEKSLHTLFGDELCKVASLRETYGDMADCCEKQEPERNECFLSHKDDSPDLPKLKPDPNTLCDEFKADEKKFWGKYLYEIARRHPYFYAPELLYYANKYNGVFQDCCQAEDKGACLLPKIETMREKVLASSARQRLRCASIQKFGERALKAWSVARLSQKFPKAEFVEVTKLVTDLTKVHKECCHGDLLECADDRADLAKYICDNQDTISSKLKECCDKPLLEKSHCIAEVEKDAIPENLPPLTADFAEDKDVCKNYQEAKDAFLGSFLYEYSRRHPEYAVSVLLRLAKEYEATLEECCAKDDPHACYSTVFDKLKHLVDEPQNLIKQNCDQFEKLGEYGFQNALIVRYTRKVPQVSTPTLVEVSRSLGKVGTRCCTKPESERMPCTEDYLSLILNRLCVLHEKTPVSEKVTKCCTESLVNRRPCFSALTPDETYVPKAFDEKLFTFHADICTLPDTEKQIKKQTALVELLKHKPKATEEQLKTVMENFVAFVDKCCAADDKEACFAVEGPKLVVSTQTALA

Detected by CID or ETD or Both

Improved sequence coverage with ETD; complementary to other methods

Comparison of Detection Methods

6

MULTIPLE

IONIZATION MODES

A variety of ionization

techniques are available

on the LTQ XL that allow for

maximum flexibility in sample analysis.

Ion Max™ sourceESI, APCI, and APPI probes arebased on the revolutionary Ion Maxsource design. It imparts superiorperformance and features simple,tool-free switching of ESI and APCIprobes. Full probe adjustment inthe x, y, and z directions allowsoptimized positioning for maximumsensitivity and robustness in bothlow and high flow applications.The 60° angle dramatically improvesperformance by reducing chemicalnoise. Maintenance of API sources,as well as switching betweenvarious probes, is vent-free.Auto matic source recognitionadds to ease of use.

Nanospray sourceThe new Nanospray ion sourcefeatures easy coupling with lowdead volume and interchangeableprobes for static, dynamic, andpacked tip nanospray. The liquidjunction provides excellent spraystability even when spraying100% aqueous mobile phase.The versatile Nanospray sourceaccommodates uncoated andpacked tip needle designs tosupport low- and high-flowapplications.

SourceConfigurations for Every Need

• Electrospray ionization (ESI)

• Atmospheric pressurechemical ionization (APCI)

• Atmospheric pressurephotoionization (APPI)

• Electron transfer dissociation(ETD)

• Nanospray ionization (NSI)

Titanium skimmer forsuperior ruggedness

Vent free removal of ion transfer tube

Tool-free interchangeof probes

LTQ Orbitrap™

…Breakthrough TechnologyCombining patented Orbitrap tech-nology with the LTQ XL linear ion trap,the LTQ Orbitrap offers fast, sensitive,reliable detection and iden ti ficationof compounds in complex mixtures.Its outstanding mass accuracy, massresolution and reliable, high sensi -tivity MSn performance make it aclear alternative to existing hybridtime-of-flight systems.

LTQ FT Ultra™

…Ultimate PerformanceThe LTQ FT Ultra combines the mostadvanced Ion Trap and Fourier Trans -form Ion Cyclotron Resonance (FT-ICR)technologies into a single instrument,with unprecedented analytical powerand versatility. Ultra-high resolutionand sensitivity, coupled with subppm mass accuracy and accuracy,enable routine analysis of even themost complex samples. ECD andIRMPD are available for top downprotein analysis.

Accurate Mass on a ChromatographicTime Scale

• Robust and reliablehigh mass accuracy

• Simultaneous high massresolution, mass accuracy,and sensitivity

• Fast data acquisitionrate with ultra highmass resolution

7

A PLATFORM FOR HIGH RESOLUTION

AND HIGH MASS ACCURACY Linear Ion TrapFT-ICR

Base Peak Chromatogram

Extracted Ion Chromatogramm/z 386.25

RT: 4.85 - 8.83

5.0 5.5 6.0 6.5 7.0 7.5 8.0 8.5Time (min)

0

10

20

30

40

50

60

70

80

90

1000

10

20

30

40

50

60

70

80

90

100

Rel

ativ

e A

bund

ance

7.55

5.79

6.45

6.00 7.396.84

7.895.34 7.11

8.708.488.105.515.24

7.55

7.897.17 8.10 8.658.326.946.616.346.125.905.735.244.90

NL: 6.16E7Base Peak F: FTMS + c ESI Full ms [180.00-1200.00] MS FT_FT_Busprione_In_Vitro_HCD_90V_03

NL: 6.16E7Base Peak m/z= 385.76-386.76 F: FTMS + c ESI Full ms [180.00-1200.00] MS

FT_FT_Busprione_In_Vitro_HCD_90V_03

384 385 386 387 388 389 390 391 392m/z

386.25522

387.25861

388.26172 391.28415386.25505

387.25799

388.26071

Experimental

Theoretical

0.44 ppm

1.60 ppm

2.60 ppm

The LTQ XL hybrid mass spectrometers have

established themselves as the new analytical

standard for research in Proteomics and

Drug Discovery.

Accurate mass determination of an in vitro buspirone sample analyzed on the LTQ Orbitrap

Tap our expertise throughout the life of your instrument. Thermo Scientific Services

extends its support throughout our worldwide network of highly trained and certified

engineers who are experts in laboratory technologies and applications. Put our team

of experts to work for you in a range of disciplines – from system installation, training

and technical support, to complete asset management and regulatory compliance

consulting. Improve your productivity and lower the cost of instrument ownership

through our product support services. Maximize uptime while eliminating the

uncontrollable cost of unplanned maintenance and repairs. When it’s time to

enhance your system, we also offer certified parts and a range of accessories

and consumables suited to your application.

To learn more about our products and comprehensive service offerings,

visit us at www.thermo.com.

Laboratory Solutions Backed by Worldwide Service and Support

©2016 Thermo Fisher Scientific Inc. All rights reserved. Mass Frontier is a trademark of HighChem, Ltd. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.

Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.

BR62208_E 08/16S

In addition to these offices, ThermoFisher Scientific maintains a network of representative organizationsthroughout the world.

Africa+43 1 333 5034 127 • [email protected]

Australia+61 2 8844 9500 • [email protected]

Austria+43 1 333 50340 • [email protected]

Belgium+32 2 482 30 30 • [email protected]

Canada+1 800 530 8447 • [email protected]

China+86 10 8419 3588 • [email protected]

Denmark+45 70 23 62 60 • [email protected]

Europe-Other+43 1 333 5034 127 • [email protected]

France+33 1 60 92 48 00 • [email protected]

Germany+49 6103 408 1014 • [email protected]

India+91 22 6742 9434 • [email protected]

Italy+39 02 950 591 • [email protected]

Japan+81 45 453 9100 • [email protected]

Latin America+1 608 276 5659 • [email protected]

Middle East+43 1 333 5034 127 • [email protected]

Netherlands+31 76 579 55 55 • [email protected]

South Africa+27 11 570 1840 • [email protected]

Spain+34 914 845 965 • [email protected]

Sweden / Norway / Finland+46 8 556 468 00 • [email protected]

Switzerland+41 61 48784 00 • [email protected]

UK+44 1442 233555 • [email protected]

USA+1 800 532 4752 • [email protected]

www.thermo.com