Loxahatchee River District Water Reclamation | Environmental Education | River Restoration 2500 Jupiter Park Drive, Jupiter, Florida 334588964 Telephone (561) 7475700 •Fax (561) 7479929 • www.loxahatcheeriver.org D. Albrey Arrington, Ph.D., Executive Director Gordon M. Boggie Harvey M. Silverman Stephen B. Rockoff Dr. Matt H. Rostock Board Member Board Member Chairman Board Member Board Member APPLICATION/INSTALLATION PROCEDURES FOR LOW PRESSURE PUMPING UNITS (DISTRICT MAINTAINED) SIMPLEX 1. Make application for service, and Pay connection fee Sign Maintenance Agreement Discuss location of pumping unit with District Staff Receive District Standard Details 2. Purchase low pressure pumping unit and appurtenances (Assessed areas – low pressure pumping unit price included in assessment) 3. Arrange for pick up of low pressure pumping unit and appurtenances (at District) Contractor to conduct Continuity test on pumps upon pickup. 4. Arrange for MANDATORY preconstruction meeting at site with: District Inspector (Call Rick Philbrick to setup 561-262-3456) Contractor Property Manager or Homeowner Electrician Plumber 5. Inspection schedule must be followed (listed in chronological oder ): A. Wetwell Inspection Plumbness/Level Anti-floatation Concrete Rim elevation to be 2”-3” above finished grade

Upload: others

Post on 04-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

Loxahatchee River District  Water Reclamation | Environmental Education | River Restoration 

2500 Jupiter Park Drive, Jupiter, Florida 33458‐8964 Telephone (561) 747‐5700 •Fax (561) 747‐9929 • www.loxahatcheeriver.org  D. Albrey Arrington, Ph.D., Executive Director

Gordon M. Boggie Harvey M. Silverman Stephen B. Rockoff Dr. Matt H. Rostock Board Member Board Member Chairman Board Member Board Member

APPLICATION/INSTALLATION PROCEDURES FOR

LOW PRESSURE PUMPING UNITS (DISTRICT MAINTAINED)

SIMPLEX

1. Make application for service, and

Pay connection fee Sign Maintenance Agreement Discuss location of pumping unit with District Staff Receive District Standard Details

2. Purchase low pressure pumping unit and appurtenances (Assessed areas – low pressure pumping unit price included in assessment) 3. Arrange for pick up of low pressure pumping unit and appurtenances (at District)

Contractor to conduct Continuity test on pumps upon pickup. 4. Arrange for MANDATORY preconstruction meeting at site with:

District Inspector (Call Rick Philbrick to setup 561-262-3456) Contractor Property Manager or Homeowner Electrician Plumber

5. Inspection schedule must be followed (listed in chronological oder): A. Wetwell Inspection

Plumbness/Level Anti-floatation Concrete Rim elevation to be 2”-3” above finished grade

Page 2: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

P a g e | 2

B. Electrical Inspection

After electrical appurtenances are installed and approved by Municipality or County, District to be notified for inspection (24 hour notice required).

Contractor/homeowner not to energize control panel until all inspections have been completed and approved and, only with District inspector on site.

C. Pump Startup Test

Continuity test Draw down test Pressure test on 1.25” effluent line

D. Plumbing Inspection

Plumbing may be moved from septic tank to wet well upon a passing pump startup and must be inspected by District staff.

E Septic Tank Abandonment and Fill

Tank pumped out Pressure washed Rupture tank Fill

Please note: All District inspections require 24 hour notice. The District strives to be proactive during the construction phase and unscheduled inspections will be made to assess progress and for conformance to LRD specifications. M:\LOW PRESSURE APPLICATION INSTALLATION PROCEDURES.doc

Page 3: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

4'(MAX)

DWELLING

R/W LINE

LOW PRESSURE FORCE MAIN

CONTROL PANEL (SEE SECTION VIEW)

1.25

" FO

RC

E M

AIN

FUSED DISCONNECT-30AMP*

SERVICE BOX

ISOLATION VALVE

3' (TYP.)

CL

CL

VALVE BOX

EDGE OF ROAD

3' DIAMETER WET-WELLWITH PUMP.

DR

IVE

WA

Y2-WAYCLEAN OUT**

APRIL, 2012LP-1

LOXAHATCHEE RIVER DISTRICT

TYPICAL RESIDENTIALGRINDER SYSTEM LAYOUT (PLAN VIEW)REVISION:

N.T.S.

*FOR DUPLEX INSTALLATIONS (5,000 sq ft or more) USE 60 AMP FUSEABLE DISCONNECT.

**REPLACE EXISTING CLEANOUT IF NOT 2-WAY.

PR

OP

ER

TY L

INE

PR

OP

ER

TY L

INE

Page 4: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

(TY

P.)

(1) SCH.80 PVC OR

2-WAY CLEAN OUT**

FUSED DISCONNECT-30AMP *

HOSE BIB

(POWER FROM HOUSE)

36" FLEX CONDUIT TO PANEL

FLOW

(1)-4"x4" JUNCTION BOX

***(1) - 2" SCH 80 PVCELEC. CONDUIT

PANEL TO TANK.

FIBERGLASSTANK - 3' DIA.

W/ PUMP INSIDE

*FOR DUPLEX INSTALLATIONS (5,000 sq ft or more) USE 60 AMP FUSEABLE DISCONNECT.

**REPLACE EXISTING CLEANOUT IF NOT 2-WAY.

CONTROL PANEL MOUNTED TO HOUSE.PANEL TO BE 3' LEFT OR RIGHT (CENTERLINETO CENTERLINE) FROM TANK LOCATION.

APRIL, 2012LP-2

LOXAHATCHEE RIVER DISTRICTTYPICAL RESIDENTIAL

GRINDER SYSTEM LAYOUT (SECTION VIEW)REVISION:

N.T.S.

***FOR DUPLEX STATIONS, USE TWO (2) - 2" SCH. 80 CONDUITS

Page 5: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

(MAX)

CLEAN OUT

4'

LP-3ALTERNATE RESIDENTIAL GRINDER SYSTEM LAYOUT (PLAN VIEW)

CLEAN OUT

DWELLING

R/W LINE

LOW PRESSURE FORCE MAIN

1.25

" FO

RC

E M

AIN

SERVICE BOX

ISOLATION VALVE

EDGE OF ROAD

DR

IVE

WA

Y

APRIL, 2012

LOXAHATCHEE RIVER DISTRICT

REVISION: N.T.S.

PR

OP

ER

TY L

INE

PR

OP

ER

TY L

INE

Page 6: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

APRIL, 2012LP-4

FINISHED GRADE

3.0'

(M

IN.)

4'-6

.75" CONDUIT

PEDESTAL CAPRED ALARM LIGHT

2" PVC CONDUIT

CONDUIT CLAMP

HINGE SIDE

BACKFILL AND COMPACT MATERIAL

PLACE 4" OF #57 ROCK UNDER PEDESTAL

22" L

ON

G

18"

22"X6"X6"X.25" THICKFIBERGLASS ANGLES ATTACHEDTO SIDES OF PEDESTAL WITH 8S.S. SCREWS (EACH SIDE)

PADLOCK INSTALLED BY DISTRICT

POWER FROM DISCONNECT BOXTO CONTROL PANEL BOX

ELECTRICAL DISCONNECT BOX:SIMPLEX - 30 AMP W/ # 10 AWG

POWER CORDS TOPUMP & FLOATS

FP&L POWER INTODISCONNECT BOX WIRESIZE #10AWG MIN.

MIN

.

NOTE:CONTRACTOR SHALL FURNISH ANDINSTALL FIBERGLASS PEDESTAL ANDFIBERGLASS NEMA 4X ENCLOSUREAND DISCONNECT SWITCH.CONTRACTOR SHALL FURNISH ANDINSTALL ALL CONDUIT AND WIRESBETWEEN PEDESTAL FIXTURES ANDLOW PRESSURE PUMP & FLOATS.

FIBERGLASS PEDESTAL/POST7'-6" LONG X 6"X9" RECT. X 3"THICK, PEDESTAL WITH CAP.BURY 3.0' IN GROUND (MIN.) #H90R96516 MFG. BY: HIGGINSPOWER SOLUTIONS, INC., OROTHER PRE-MANUFACTUREDPOST WITH LRD APPROVAL.

FIBERGLASS ENCLOSURENEMA 4X

PANEL MOUNTING TABS(4 EACH)

LOXAHATCHEE RIVER DISTRICT

ALTERNATE RESIDENTIAL GRINDERSYSTEM LAYOUT FREE STANDING (1 OF 2)

N.T.S.REVISION:

4" X 4" PVC JUNCTION BOXOR PER LOCAL BUILDINGAUTHORITY.

* FOR RESIDENTIAL SIMPLEX STATIONS ONLY

Page 7: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

TO F

LOA

TS

TO P

UM

P

FROM POWER SOURCE

PANEL

CL

PLAN VIEW

24"(MIN.)

DISCONNECT

1.5" 304 S.S. PIPE SUPPORT(TYP.) OR GALV. EMT OR ALUM.

CONTROL PANEL MOUNTINGS.S. SHALLOW UNISTRUT,UNISTRUT STRAP.

DISCONECT. USE 60 AMPFUSEABLE USE #6 AWG WIRE MIN.

1.5" 304 SS PIPE SUPPORT (TYP.) ORALUMINUM, OR GALVANIZED EMTIF GALVANIZED EMT, ALL PORTIONSIN CONCRETE SHALL BE COATED INBITUMASTIC TO 2" ABOVE CONC. PAD

POURED CONCRETE BASE12" DIA x 36" DEEP (TYP.)

NOTE:ALL GROUNDING TO BE PERN.E.C. AND/ OR LOCAL CODES

SEAL CONDUIT (TYP.)

NEMA 4XFIBERGLASSENCLOSURE

HASP & DISTRICTSUPPLIED LOCK

RED LIGHT "HIGH WATER ALARM" (SEE DETAIL)

ROUND 1.5" PVC CAP (TYP.)

JUNCTION BOXPER LOCAL BLDG.DEPT.

*(3) - 2" SCH 80 PVC

36" T

O C

EN

TER

OF

PA

NE

L36

" MIN

.

APRIL, 2012LP-5

LOXAHATCHEE RIVER DISTRICT

ALTERNATE RESIDENTIALGRINDER SYSTEM LAYOUT FREE STANDING (2 OF 2)

N.T.S.

FRONT ELEVATION

REVISION:

* FOR RESIDENTIAL DUPLEX STATIONS ONLY

Page 8: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

11"

12"

TO CONTROL PANEL 4" MIN. OF #57 STONE BASE

PVC UNION

2'MAX.

CL

2"

VA

RIE

S (

5' O

R 6

')

*

(NATURAL OR NATIVE SOIL UNDER BASE)

CL

3'-0

" (M

IN.)

* *

**

SCH. 80 PVC PIPING (INSIDE)

** * *

*

*

PLACE 8 BAGS OF DRY CONCRETE MIXEQUALLY SPACED AROUND CIRCUMFERENCEOF THE FLOATATION COLLAR.

DRILL 2" OPENING FOR 1.25"PIPE & GROMMET FOR THEF.M. CONNECTION LOCATEAND ORIENT IN FIELD

TO F.M. CONNECTIONAT R/W LINE (SEEDETAIL LP-9)

DRILL 3" OPENING FOR 2"GROMMET FOR THEELECTRICAL CONNECTIONLOCATE AND ORIENT INFIELD

INLET

DRILL 5" OPENING FORSEWER SERVICECONNECTION, LOCATEAND ORIENT IN FIELD

VACUUM BREAKER ASSEMBLY:1.25" TEE W/1.25" SLIP X .75"FEMALE THREAD BUSHING, 1.75"PVC NIPPLE, .75" CHECK VALVEINVERTED POSITION W/ (2) - .75"90° BENDS

S.S.FLOAT & 6-HOOKCABLE HOLDER

STAINLESS STEELMOUNTING STAND(BY PUMP MFG.)

SUBMERSIBLEGRINDER PUMP (2HPMIN.DUAL-SEAL) (SEESPECIFICATIONS)

36" MIN. DIA. REINFORCEDFIBREGLASS BASIN, MUSTMEET ASTM "D-3753"SPECIFICATION.

MERCURY SWITCH LEVELCONTROL-MINI ROTOFLOAT BY ANCHORSCIENTIFIC W/INTERNALWEIGHT

WET WELLCONNECTIONS FOR 1.25",2" & 4" PIPE (SEE DETAILLP-20) (SEE NOTE)

1.25"SCH. 80PVCPIPING

ALUM. LID W/ 2/3RDHINGED SINGLE LEAFLOCKABLE DOOR300PSF RATED

NEW PUMPLOCATIONROTATED 90°OFFSET

2 - 1.25" PVC BALL VALVES (SOC X SOC)

1.25" TEE WITH THREADEDCAP (SUPPLIED BY DISTRICT)

METER BOX "NDS" MODEL NO.113 BC WITH GREEN COVERMARKED "SEWER" ON LID(12"X17" SIZE) (SUPPLIED BYDISTRICT)

6" ANTI-FLOTATION COLLAR

1.25" RISER PIPE LENGTH TO BE VERIFIEDAND CUT IN FIELD TO MATCH F.M. OUTLET

*

1.25" PVC WYE BALL CHECK VALVE

WET WELL SHALL BE FIBERGLASS WITHPRE-PIPED PUMP DISCHARGE ASSEMBLY.

SCH. 40 PVC PIPING (OUTSIDE) SUPPLIEDBY MANUFACTURER TO VALVE BOX

NOTE:CONNECTION TO WET-WELL FOR ELECTRICAL ANDSEWER OPENINGS SHALL BE INSTALLED BYCONTRACTOR WITH 1.25", 2" OR 4" RUBBERGROMMETS SUPPLIED BY THE MANUFACTURER,GRINDER PUMP SHALL BE "BARNES SERIES SGVF".

*** PUMP SPECIFICATIONS:BARNES-GRINDER PUMP #SGVF2022L, 2HP, 230V, 1PH, 60HZ, 5.13" IMPELLER

APRIL, 2012LP-6

LOXAHATCHEE RIVER DISTRICT

RESIDENTIAL SIMPLEXTYPICAL WET WELL

N.T.S.REVISION:

Page 9: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

XFMR1R

MS

C CC

BREAKERS

2R S

R

A

N B

C MP

B

A

ETM

RL

AL

GFI

ATB ASB

AH

BREAKERS

CAP.PACK

APRIL, 2012LP-7

LOXAHATCHEE RIVER DISTRICTN.T.S.

BACKPLATE LAYOUT (TYP.)

ENCLOSURE & DEADFRONT(TYP.)

RESIDENTIAL SIMPLEXCONTROL PANEL LAYOUT

OH

BILL OF MATERIALS

GE START RELAY, 16104MARS STRT CAP 250V 124-156MF, 11148

CAP.PACK: MARS RUN CAP OVAL 45MF/440V, 12448

* OR APPROVED EQUAL

GRINDER PUMP'STO MATCH

PANEL & COMPONENTS SHALL CONFORM TOINDUSTRIAL UL LISTING PRE SEC. 508 N.E.C.

*

BCG

BROBROY NEMA 4X, RJ1816HPLSQ-D, QOU230SQ-D, QOU115SQ-D, 8502SBO2VO2SSQ-D, B25SQ-D, 9070T50D13CONTR. DYN. 120VAC, HMA303MCGILL 20A, 910003BACO 22M, L20SA50STONCO, VP11GCRFLOYD BELL, MC09201QIDEC, SR3B05SQ-D, ZB4BA0SQ-D, ZB4BA2PASS SEYMOUR, 1595WBUSS, MDL-1

SQ-D, 9065SEO5IDEC, RR2PULAC24VIDEC, SR2P06

FIBERGLASS ENCLOSUREPUMP & MAIN BREAKERSGFI & CONTROL BREAKERSSTARTEROVLD HTR ELEMENTTRANSFORMER 50VAELAPSED TIME METERHAND OFF AUTO SWITCHRUN LIGHTALARM LIGHTALARM HORNALARM SILENCE RELAYALARM SILENCE BUTTONALARM TEST BUTTON15 AMP GFI RCPTFUSE 1A

OVERLOAD RELAYCONTROL RELAY8-PIN SOCKET

ENCPCB/MCBCCB/GCBMSOLXFMRETMHOARLALAH*ASRASBATBGFIFU1

OLCR1-2CR1-2

CAPACITORPACK SUPPORT

DETAIL

AL

ENCLOSURE & DEADFRONT(TYP.)

4X TYPE LATCHES

4X TYPE LATCHES

PADLOCKING HASPAND STAPLE18

"

16"

18"

16"

STARTRELAY

TERMINALSTRIP

BUSS, MDL-2FUSE 2AFU2BUSS, BKS82021FUSE BLOCKFU1-2

REVISION:

ALTECH, TSF6O12WPTERMINAL STRIPTS

Page 10: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

RC

SC

CB1-30AMPMS

RED

BLU

1SR

25

BLK

WHT GRINDER2 HP

15.0 F.L.A.

CBM-30AMP

CB2-15AMP

CB3-15AMP

120/240 VOLT1 PHASE3 WIRE

LS3

LS1

CR1

1 3CR2

LS2 CR1

FU2- 2AMP

FU1- 1AMP

AUTOPUMPOFFHAND

SW

8 6

CR1

TS OL MS

ETM

A RUNNING

CR2

1 3CR3

47

1

R LIGHTALARM

HORNALARM

CR3

PB2

LS1-

PU

MP

ON

PU

MP

OFF

HIG

H A

LAR

M

LS2-

LS3-

SE

E N

OTE

4TS

TERMINAL STRIP

76541 2 3 8

NOTES:

RELAYSILENCE

1 2 43

65

7 8

TEST

N N

2 #10

2 W21

3

45

6 7

8

12119

10

13

14

15

W

RED

BLKBLK

SILENCE

GFI

OL2 #12

16

PB1

WHT

BLK

RED

24 VOLT

120 VOLTTR- 50 VA

1.) PANEL GROUND TERMINAL MUST BE CONNECTED TO EARTH GROUND.2.) FACTORY WIRING IS SHOWN FIELD WIRING IS SHOWN3.) RECOMMENDED TIGHTENING TORQUES FOR TERMINALS 240 VOLT POWER

30 POUND INCHES. 120 VOLT POWER, CONTROL & LOW VOLTAGE -20 POUND INCHES.

4.) THERMAL SAFETY SWITCH (TS) CONTACTS ARE NOT IN ALL MOTORS. IFMOTOR DOES NOT HAVE SWITCH, THESE TERMINALS MUST BE JUMPERED.

5.) LAYOUT TO MEET CUSTOMER'S REQUIREMENTS.

LP-8

LOXAHATCHEE RIVER DISTRICT

RESIDENTIAL SIMPLEXELECTRICAL SCHEMATICAPRIL, 2012

N.T.S.REVISION:

2

1

2 #14

Page 11: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

TYPICAL ROAD CROSSING SECTION VIEW

2"GRADE

PROPERTY LINE

(TY

P.)

5'

PLAN VIEW

E.M.S.

R/W

LIN

EE.M.S.

(TYP)12"

12" 6"

E.M.S.

18"

GRADE

18"

1.5" PVC SCH.40(SINGLE SERVICE)

NOTE:SERVICE PIPE TOPUMP UNIT, MIN.12" BELOW GRADE

EDGE OF SERVICE BOX SHALL BE 18"BEHIND SIDEWALK OR R/W LINE

1.5" PVC SCH.40 (SINGLE SERVICE)

LOW PRESSURE FORCE MAIN

12" NIPPLE W/GLUED CAP (TYP)

ISOLATION VALVE(SEE NOTE #2)

LOW PRESSUREFORCE MAIN

1.5" 90° SERVICE LATERAL

VALVE BOX SHALL BE TYLER UNION:141-Q FOR 22"X30"DEPTH142-R FOR 30"X42"DEPTHWITH COVER MARKED "SEWER"SEE NOTE #6

NOTES:1. ACTUAL LOCATIONS OF SERVICES SHALL BE DETERMINED IN FIELD BY RESIDENT ENGINEER DEPENDING UPON EXISTING CONDITIONS & LOCATION OF EXISTING SEPTIC TANK.2. IN R.O.W. ALL BALL VALVES SHALL BE FORD BRASS BALL VALVE CURB STOP #B11-666 FOR 1.5"

3. SEE PLAN SHEET FOR LOCATION OF SERVICES.4. 4" MIN. OF #57 ROCK BEDDING SHALL BE PLACED BELOW VALVE BOXES.5. VALVES INSIDE SERVICE BOX SHALL BE SCH 40 1.5" PVC BALL VALVE, SLIP X SLIP. CHECK VALVE SHALL BE 2" "FLOWMATIC" PVC BALL CHECK VALVE, (MODEL-208S) SLIP X SLIP WITH 2"X1.5" BUSHINGS.

SERVICE BOX:CDR FLARED SERVICE BOXMODEL #B10111812A(11"X18"X12") WITH COVER#C00111802A. COVER MARKED"SEWER" AND COLORED GREEN.ALSO REFER TO NOTE # 5.

IF ROAD CROSSING IS NECESSARY,SERVICE LATERAL TO BE INSTALLED VIAPNUEMATIC MOLE METHOD

12" MAX.

SEE NOTE #4

W/ FORD QT67 OPERATING NUT, USE BRASS NIPPLES EACH SIDE OF BRASS BALL VALVES.

APRIL, 2012LP-22

LOXAHATCHEE RIVER DISTRICT

TYPICAL SINGLE SERVICE SCHEMATICN.T.S.

36" M

IN.

(TY

P)

REVISION:

6. WHERE SERVICES ARE BORED UNDER A ROADWAY, A VALVE BOX SHALL BE CONSTRUCTED WITH THE ISOLATIONVALVE (SEE DETAILS ABOVE). OTHERWISE, THE ISOLATION VALVE SHALL BE DIRECT BURIED WITH AN EMS MARKERAND NO VALVE BOX.

R/W LINE

E.M.S. MARKER

Page 12: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

PROPERTY LINE

PLAN VIEW

E.M.S.

(TYP)12"

12" 6"

18" EDGE OF SERVICE BOX SHALL BE 18"BEHIND SIDEWALK OR R/W LINE

1.5" PVC SCH.40 (DOUBLE SERVICE)

SCH 40 PVC LOWPRESSURE FORCE MAIN

12" NIPPLE W/GLUED CAP (TYP)

R/W

LIN

E

24"

(TY

P.)

(TY

P.)

1.5" 90° BEND

1.5" 90° BEND

1.5" TEE (VERTICAL) 1.5" SCH. 40 PVC

(TYP)12"

E.M.S.

TYPICAL SINGLE SERVICE BOX.LOCATION ALONG R/W LINETO BE DETERMINED IN FIELD.(SAME AS LISTED ABOVE)

24"

TYPICAL ROAD CROSSING SECTION VIEW

2"GRADE

E.M.S.

SERVICE BOX:CDR FLARED SERVICE BOX MODEL #B10111812A(11"X18"X12") WITH COVER #C00111802A. COVER MARKED"SEWER" AND COLORED GREEN. ALSO REFER TO NOTE # 5.

1.5" PVC SCH.40(SINGLE SERVICE)

NOTE:SERVICE PIPE TOPUMP UNIT, MIN.12" BELOW GRADE

LOW PRESSUREFORCE MAIN

1.5" 90°

NOTES:1. ACTUAL LOCATIONS OF SERVICES SHALL BE DETERMINED IN FIELD BY RESIDENT ENGINEER DEPENDING UPON EXISTING CONDITIONS & LOCATION OF EXISTING SEPTIC TANK.2. IN R.O.W. ALL BALL VALVES SHALL BE FORD BRASS BALL VALVE CURB STOP #B11-666 FOR 1.5"

3. SEE PLAN SHEET FOR LOCATION OF SERVICES.4. MIN. 4" OF #57 ROCK BEDDING SHALL BE PLACED BELOW SERVICE BOXES.5. VALVES INSIDE SERVICE BOX SHALL BE SCH 40 1.5" PVC BALL VALVE, SLIP X SLIP. CHECK VALVE SHALL BE 2" "FLOWMATIC" PVC BALL CHECK VALVE, (MODEL-208S) SLIP X SLIP WITH 2"X1.5" BUSHINGS.

12" MAX.

SEE NOTE #4

W/ FORD QT67 OPERATING NUT, USE BRASS NIPPLES EACH SIDE OF BRASS BALL VALVES.

APRIL, 2012LP-23

LOXAHATCHEE RIVER DISTRICT

TYPICAL DOUBLE SERVICE SCHEMATICN.T.S.

E.M.S.

18"

GRADE

ISOLATION VALVE(SEE NOTE #2)

REVISION:

VALVE BOX SHALL BE TYLER UNION:141-Q FOR 22"X30"DEPTH142-R FOR 30"X42"DEPTHWITH COVER MARKED "SEWER"SEE NOTE #6

6. WHERE SERVICES ARE BORED UNDER A ROADWAY, A VALVE BOX SHALL BE CONSTRUCTED WITH THE ISOLATIONVALVE (SEE DETAILS ABOVE). OTHERWISE, THE ISOLATION VALVE SHALL BE DIRECT BURIED WITH AN EMS MARKER

AND NO VALVE BOX.

36" M

IN.

(TY

P)

SERVICE LATERAL

R/W LINE

IF ROAD CROSSING IS NECESSARY,SERVICE LATERAL TO BE INSTALLED VIAPNUEMATIC MOLE METHOD

Page 13: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

1. LOW PRESSURE PUMPING UNITS SHALL BE LOCATED SO THAT SURFACE WATER RUN OFF SHALL NOT INTERFEREWITH ELECTRICAL COMPONENTS.

2. MANUFACTURER SHALL SUPPLY AND ATTACH ELECTRICAL CONTROL PANEL SCHEMATIC TO INSIDE FACE OF CONTROL PANEL DOOR (LAMINATED).

3. THE DISTRICT WILL BE CERTIFYING ALL LOW PRESSURE LIFT STATIONS WHEN COMPLETE. MANUFACTURERSHALL SCHEDULE A START UP TEST AND SUBMIT ALL AS-BUILT DATA TO THE DISTRICT FOR CERTIFICATION.

4. LIFT STATION AND CONTROL PANEL SHALL BE LOCATED SO THAT BOTH ARE ACCESSIBLE FOR MAINTENANCE.

5. WHERE FEASIBLE, HOMEOWNER SHALL PROVIDE WATER HOSE BIB. HOSE FOR MAINTENANCE OPERATIONS.

6. AIR RELEASE VALVE AND/OR VACUUM RELIEF VALVES SHALL BE PROVIDED ON ALL LOW PRESSURE FORCEMAIN INSTALLATION IMMEDIATELY UPSTREAM OF DISCHARGE POINT TO REGIONAL GRAVITY OR FORCE MAINSYSTEMS.

7. FORCE MAIN DETECTABLE TAPE & MAGNETIC LOCATING DEVICES WILL BE INSTALLED OVER FORCE MAIN,VALVES, AND SERVICES.

APRIL, 2012LP-35

LOXAHATCHEE RIVER DISTRICT

GENERAL NOTESN.T.S.

REVISION:

Page 14: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

Loxahatchee River District  Water Reclamation | Environmental Education | River Restoration 

2500 Jupiter Park Drive, Jupiter, Florida 33458‐8964 Telephone (561) 747‐5700 •Fax (561) 747‐9929 • www.loxahatcheeriver.org  D. Albrey Arrington, Ph.D., Executive Director

Gordon M. Boggie Harvey M. Silverman Stephen B. Rockoff Dr. Matt H. Rostock Board Member Board Member Chairman Board Member Board Member

LOW PRESSURE SEWER SYSTEM

GENERAL OPERATING INSTRUCTIONS

GENERAL INFORMATION Your home is equipped with a wastewater disposal system known as a low pressure grinder pump system. The key element of the system is the self contained grinder pump unit. The fiberglass tank, which houses the pump, collects all the effluent from your house which previously discharged to a septic tank. The solid materials are then ground to a small size suitable for pumping as a slurry with the effluent water. The grinder pump generates sufficient pressure to pump this slurry from your home through a low pressure force main to the nearest existing sanitary collection system. There are shut off and check valves that isolate your pumping unit from the low pressure force main in the street right-of-way. These valves are located in boxes at your front property line and at the pumping unit. You should be familiar with their location and operation in the event on site repairs are necessary. Additionally, you should make a location sketch of the small PVC force main between the pumping unit and the street right-of-way line. Keep this sketch in a safe place for future reference. The District can assist you in locating these valves. Listed below are typical instructions that are being recommended to users of a grinder pump low pressure system:

1. The following items should not be introduced into any house sewer, either directly or through a garbage disposal unit:

a. Glass b. Metal c. Cloth (socks, rags, etc.) d. Plastic Objects (toys, utensils, etc.) e. Diapers, Diaper Wipes, Sanitary Napkins or Tampons f. Fats, Oils and Grease (FOG)

g. Bones and other grease laden products

2. Grease - Grease in the wet well is a major cause of system backups. Float switches, which regulate the liquid levels in the pumping chamber, can be made inoperative by accumulations of grease on the float system. As with any sewer system, every effort should be made to remove grease from dishes and eating utensils prior to operating dishwashers and garbage disposal units.

Page 15: Loxahatchee River District · fiberglass pedestal/post 7'-6" long x 6"x9" rect. x 3" thick, pedestal with cap. bury 3.0' in ground (min.) # h90r96516 mfg. by: higgins power solutions,

P a g e | 2

3. Never introduce into any sewer: a. Explosives b. Flammable Material c. Lubricating Oils and/or Grease d. Strong Chemicals e. Gasoline f. Paints

4. Unoccupied Homes - If your home is left unoccupied for longer than a week or two, the pump system should be purged, i.e. run clean water into the pumping until the pump starts. Turn off the water supply and allow the pump to run until it shuts off automatically. Do not disconnect power to the unit. 5. Power Failure - Obviously, like other household appliances a grinder pump cannot operate and dispose of wastewater without electrical power. The storage capacity of most units varies between 70 and 80 gallons. This is an adequate reserve for an average one family home for at least 24 hours if water usage is kept to a minimum. Keep in mind that the normal toilet uses about 3 to 5 gallons per flush. 6. Pump Failure Alarm - Your low pressure grinder pump contains a built in alarm signal which will activate in the event of a high liquid level in the basin. This signal is connected to a visual and/or audible alarm which will provide you with adequate warning that service is required. During the interval prior to the arrival of a service technician, water usage should be kept to a minimum. During normal working hours you can call 747-5709 for an emergency. After hours, the emergency number is 747-5708. 7. District Response in Emergencies – Maintenance of the pumping unit and its components will be the responsibility of the District for all residential and 3 phase non-residential low flow units. The covers all labor involved for emergency calls or normal maintenance and any parts or materials that are used.

M:\LOW PRESSURE SEWER SYSTEM\LOW PRESSURE APPLICATION INSTALLATION PROCEDURES.doc