Low voltage Extract from Tesys Catalogue | 2016

Motorstarters

Protection

Reliable

Thermal overload relays

Circuit breakers

Motor

Contactors

Flexible

Smar

t

controllers

Fuse switch-disconnectors

TeSys Motor controllers

B12/1

Mo

tor

con

tro

llers

Motor management systems

Motor management system - TeSys U Type of product Range Pages

Motor controller TeSys U B12/2

Current transformers for TeSys U motor controller From 30 to 800 A B12/2

Type 2 coordination table for assemblies of: b circuit breaker + contactor + TeSys U controller + current transformerb fuses + contactor + TeSys U controller + current transformer

B12/3

Motor management system - TeSys T

Controllers with Modbus, or CANopen, Devicenet, Profibus, Ethernet TCP/IP communication port

B12/4

Extension modules B12/5

HMI terminal and cables B12/5

Accessories B12/6

TeSy

s Control and Protection Components

Chapter

B12

Technical Data for Designers B12/9

B12/2

TeSys U

ReferencesControl bases (auxiliary supply voltage c 24 V)Connection For use

with contactorReference Weight

kg Current transformers

Control

Screws Screws LC1Dpp LUTM10BL 0.800

LC1Fppp LUTM20BL 0.800

Control unitsDescription Class For motor

typeSetting range Reference Weight

kgAdvanced 10 3-phase 0.35…1.05 LUCBT1BL 0.140

20 3-phase 0.35…1.05 LUCDT1BL 0.140

Multifunction 5 to 30 3-phase 0.35…1.05 LUCMT1BL 0.175

Current transformersOperating current Reference Weight

kgPrimary Secondary30 1 LUTC0301 0.550

50 1 LUTC0501 0.330

100 1 LUTC1001 0.450

200 1 LUTC2001 0.590

400 1 LUTC4001 0.870

800 1 LUTC8001 1.210

Function modules and communication modulesThe TeSys U controller is compatible with the modules listed below:

b Thermal overload alarm module LUF W10, b Motor load indication module LUF V2, b Communication modules: v Modbus (LUL C033), v CANopen (LULC08), v DeviceNet (LULC09), v Advantys STB (LUL C15).

Note: Communication modules LUL C07 (Profibus DP), ASILUF C5 and ASILUF C51 (AS-Interface) are not compatible with the TeSys U controller. Module LUF W10 is only compatible with control units LUCB T1BL and LUCD T1BL. 

References Motor management systemTeSys U controllers

Presentation: pages B12/10 and B12/11

Characteristics: pages B12/12 and B12/13

Dimensions, mounting: page B12/14

Schemes: page B12/15

LUT M + LUCM T1BL + LUTC pp

DF5

2612

0.tif

B12/3

TeSys U

Mo

tor

con

tro

llers

Combinations providing type 2 coordinationWith Circuit breakerStandard power ratings of 3-phase motors 50-60 Hz in category AC-3 400/415 V

Circuit breaker Contactor TeSys U controller

Current transformers

PkW IeA Reference Rating A

Irm (1)

AReference (2) Reference Reference

18.5 35 GV3L40 40 560 LC1D50A LUTM + LUCp 3 x LUTC050122 41 GV3L50 50 700 LC1D50A LUTM + LUCp 3 x LUTC100130 55 GV3L65 65 910 LC1D65A LUTM + LUCp 3 x LUTC100137 66 NSX80HMA 80 1040 LC1D80 LUTM + LUCp 3 x LUTC100145 80 NSX100HMA 100 1300 LC1D95 LUTM + LUCp 3 x LUTC100155 97 NSX160HMA 150 1350 LC1D115 LUTM + LUCp 3 x LUTC200175 132 NSX160HMA 150 1800 LC1D150 LUTM + LUCp 3 x LUTC200190 160 NSX250HMA 220 2200 LC1F185 LUTM + LUCp 3 x LUTC2001110 195 NSX250HMA 220 2640 LC1F225 LUTM + LUCp 3 x LUTC4001132 230 NSX400HMA 320 3200 LC1F265 LUTM + LUCp 3 x LUTC4001160 280 NSX400HMA 320 4160 LC1F330 LUTM + LUCp 3 x LUTC4001200 350 NSX630HMA 500 5000 LC1F400 LUTM + LUCp 3 x LUTC4001220 385 NSX630HMA 500 5500 LC1F400 LUTM + LUCp 3 x LUTC4001250 430 NSX630HMA 500 6000 LC1F500 LUTM + LUCp 3 x LUTC8001

With fusesStandard power ratings of 3-phase motors 50-60 Hz in category AC-3 400/415 V

Switch-disconnector fuse

aM fuses Contactor TeSys U controller

Current transformers

PkW IeA Reference Size Rating A

Reference (2) Reference Reference

18.5 35 GSpF 14 x 51 40 LC1D40A LUTM + LUCp 3 x LUTC050122 41 GSpJ 22 x 58 50 LC1D50A LUTM + LUCp 3 x LUTC100130 55 GSpJ 22 x 58 80 LC1D80 LUTM + LUCp 3 x LUTC100137 66 GSpJ 22 x 58 100 LC1D80 LUTM + LUCp 3 x LUTC100145 80 GSpJ 22 x 58 100 LC1D95 LUTM + LUCp 3 x LUTC100155 97 GSpL T0 125 LC1D115 LUTM + LUCp 3 x LUTC200175 132 GSpL T0 160 LC1D150 LUTM + LUCp 3 x LUTC200190 160 GSpN T1 200 LC1F185 LUTM + LUCp 3 x LUTC2001110 195 GSpN T1 250 LC1F225 LUTM + LUCp 3 x LUTC4001132 230 GSpQQ T2 315 LC1F265 LUTM + LUCp 3 x LUTC4001160 280 GSpQQ T2 400 LC1F330 LUTM + LUCp 3 x LUTC4001200 350 GS2S T3 500 LC1F400 LUTM + LUCp 3 x LUTC4001220 385 GS2S T3 500 LC1F400 LUTM + LUCp 3 x LUTC4001250 430 GS2S T3 500 LC1F500 LUTM + LUCp 3 x LUTC8001315 540 GS2S T3 630 LC1F630 LUTM + LUCp 3 x LUTC8001

(1) Irm: setting current of the magnetic trip.(2) For reversing operation, replace the prefix LC1 with LC2.

Combinations Motor management systemTeSys U controllers

Presentation: pages B12/10 and B12/11

Characteristics: pages B12/12 and B12/13

References: page B12/2

Dimensions, mounting: page B12/14

Schemes: page B12/15

B12/4

TeSys T

ControllersSetting range Control voltage Current range Reference

A V AFor Modbus

8 c 24 0.4...8 LTMR08MBDa 100...240 0.4...8 LTMR08MFM

27 c 24 1.35...27 LTMR27MBDa 100...240 1.35...27 LTMR27MFM

100 c 24 5...100 LTMR100MBDa 100...240 5...100 LTMR100MFM

For CANopen8 c 24 0.4...8 LTMR08CBD

a 100...240 0.4...8 LTMR08CFM27 c 24 1.35...27 LTMR27CBD

a 100...240 1.35...27 LTMR27CFM100 c 24 5...100 LTMR100CBD

a 100...240 5...100 LTMR100CFMFor DeviceNet

8 c 24 0.4...8 LTMR08DBDa 100...240 0.4...8 LTMR08DFM

27 c 24 1.35...27 LTMR27DBDa 100...240 1.35...27 LTMR27DFM

100 c 24 5...100 LTMR100DBDa 100...240 5...100 LTMR100DFM

For Profibus DP8 c 24 0.4...8 LTMR08PBD

a 100...240 0.4...8 LTMR08PFM27 c 24 1.35...27 LTMR27PBD

a 100...240 1.35...27 LTMR27PFM100 c 24 5...100 LTMR100PBD

a 100...240 5...100 LTMR100PFMFor Ethernet TCP/IP (communication protocols: Modbus/TCP and EtherNet/IP)

8 c 24 0.4...8 LTMR08EBDa 100...240 0.4...8 LTMR08EFM

27 c 24 1.35...27 LTMR27EBDa 100...240 1.35...27 LTMR27EFM

100 c 24 5...100 LTMR100EBDa 100...240 5...100 LTMR100EFM

FilterControl voltage Current max ReferenceV mA

a 150...240 130 LTM9F

References Protection componentsTeSys T Motor Management System

LTM R08EBD

CP

B10

0750

-00.

eps

PF5

2638

7-47

-M.e

ps

LTM R08MBD

PF5

2638

8-47

-M.e

ps

LTM R08CBD

PF5

2638

9-47

-M.e

ps

LTM R08DBD

PF5

2639

0-47

-M.e

ps

LTM R08PBD

Presentation: pages B12/16 to B12/26

Characteristics: pages B12/27 to B12/31

Dimensions, mounting: pages B12/32 to B12/33

Schemes: pages B12/34 to B12/37

Combination for customer assembly: pages B12/38 to B12/41

B12/5

TeSys T

Mo

tor

con

tro

llers

References

Extension modules (with voltage measurement on the 3 phases)Input control voltage

Number of inputs

Supply to the electronics Reference

Vc 24 4 Via the controller LTMEV40BD a 100…240 4 Via the controller LTMEV40FM

HMI terminalsDescription Supply

VoltageReference

Operator control unit

Languages:EnglishFrenchSpanish

Supply via the controller

LTMCU

Operator control unit with Fast DeviceReplacement Service (FDR)

Languages:EnglishFrenchSpanish

Supplyvia the controller

LTMCUF

Kit for portable LTM CU LTM9KCUMagelis compact display. c 24 V external XBTN410Description Number and type

of connectorsLengthm

Reference

Connecting cables for the LTM CU control unit

2 x RJ45 1 LTM9CU103 LTM9CU30

Connecting cablesfor the XBT N410

SUB-D 25-way female RJ45

2.5 XBTZ938

CablesDescription Number and type

of connectorsLength Referencem

Connecting cables For connecting the controller to the extension module

2 x RJ45 0.04 LTMCC004 (1)

0.3 LTM9CEXP031 LTM9CEXP10

Replacement connectorsDescription Number and type

of connectorsReference

Complete set of connectors for controllers and extension modules

10 screw terminals (all network versions included)

LTM9TCS

Connector extraction tool LTM9TCT (2)

(1) Sold in lots of 6.(2) Sold in packs of 3.

Protection componentsTeSys T Motor Management System

LTM EV40BD

PF5

2638

0-30

-M.e

ps

LTM CU

PF5

6860

5-54

-M.e

ps

Presentation: pages B12/16 to B12/26

Characteristics: pages B12/27 to B12/31

Dimensions, mounting: pages B12/32 to B12/33

Schemes: pages B12/34 to B12/37

Combination for customer assembly: pages B12/38 to B12/41

B12/6

TeSys T

References

Configuration toolsDescription Composition Reference Weight

kgConnection cable for PC USB to RJ45 cable, lenght 2.5 m TCSMCNAM3M002P 0.200

Current transformers (1)

Operational current Reference WeightPrimary SecondaryA A kg

100 1 (2) LT6CT1001 0.550200 1 (2) LT6CT2001 0.550400 1 (2) LT6CT4001 0.550800 1 (2) LT6CT8001 0.680

Earth fault toroids (marketed under the Schneider Electric brand)Rated operational current Ie

Internal Ø of toroid

Reference Weight

A mm kgClosed toroids, type A

65 30 50437 0.12085 50 50438 0.200160 80 50439 0.420250 120 50440 0.530400 200 50441 1.320630 300 50442 2.230

Split toroids, type OA85 46 50485 1.300250 110 50486 3.200

PTC thermistor probes (3)

Description Nominal Operating Temperature (NOT)

Colour Unit reference (4)

°CTriple probes 90 Green/green DA1TT090

110 Brown/brown DA1TT110120 Grey/grey DA1TT120130 Blue/blue DA1TT130140 White/blue DA1TT140150 Black/black DA1TT150160 Blue/red DA1TT160170 White/green DA1TT170

(1) The transformers offered for use with TeSys U starters are suitable.  Please consult our "TeSys U starter-controllers" catalogue.(2) For use with LTM R08pp controllers.(3) PTC: Positive Temperature Coefficient.(4) Sold in lots of 10.

Protection componentsTeSys T Motor Management System

LT6 CT4001

PF5

2639

3.ep

s

DA1 TTppp

PF5

1057

5.ep

s

Presentation: pages B12/16 to B12/26

Characteristics: pages B12/27 to B12/31

Dimensions, mounting: pages B12/32 to B12/33

Schemes: pages B12/34 to B12/37

Combination for customer assembly: pages B12/38 to B12/41

B12/7

TeSys T

Mo

tor

con

tro

llers

References

Marking accessories (to be ordered separately)Description Composition Height

mm

Unit reference

Weight

kgClip-in markers Strips of 10 identical

numbers (0 to 9) or capital letters (A to Z)

5 NSYTRABF5p (1) 0.002

6 NSYTRABF6p (1) 0.002

Connection accessoriesDescription Length Reference Weight

m kgFor Modbus connection

Cables fitted with 2 x RJ45 connectors 0.3 VW3A8306R03 0.0451 VW3A8306R10 0.0653 VW3A8306R30 0.125

T-junctions 0.3 VW3A8306TF03 0.0321 VW3A8306TF10 0.032

RS 485 line terminator – VW3A8306R 0.012

For CANopen connectionCables 50 TSXCANCA50 4.930

100 TSXCANCA100 8.800300 TSXCANCA300 24.560

IP20 connectorsSUB-D 9-way femaleLine end adapter switch

Elbowed (90°) – TSXCANKCDF90T 0.046Straight – TSXCANKCDF180T 0.049Elbowed (90°) with SUB-D 9-way connector for connection to PC or diagnostic tool

– TSXCANKCDF90TP 0.051

For DeviceNet connectionCables 50 TSXCANCA50 4.930

100 TSXCANCA100 8.800300 TSXCANCA300 24.560

For Profibus DP connection (2)

Cables 100 TSXPBSCA100 –400 TSXPBSCA400 –

Connectors With line terminator – 490NAD91103 –

Without line terminator – 490NAD91104 –

With line terminator and terminal port

– 490NAD91105 –

For Ethernet TCP/IP connectionShielded twisted pair cables to standard EIA/TIA568

Cables fitted with 2 x RJ45 connectors for connection to terminal equipment

Straight 2 490NTW00002 –5 490NTW00005 –12 490NTW00012 –40 490NTW00040 –80 490NTW00080 –

Shielded twisted pair cables, UL and CSA 22.1 approvedCables fitted with 2 x RJ45 connectorsfor connection to terminal equipment

Straight 2 490NTW00002U –5 490NTW00005U –12 490NTW00012U –40 490NTW00040U –80 490NTW00080U –

Ethernet Connector Elbowed 180° LTM9CE180T (3) 0.180(1) When ordering, replace the p in the reference with the number or letter required.(2) To order other connectors and cables (UL cables for harsh environments, etc.),  please consult our Customer Care Centre.(3) Sold in packs of 6.

Protection componentsTeSys T Motor Management System

Presentation: pages B12/16 to B12/26

Characteristics: pages B12/27 to B12/31

Dimensions, mounting: pages B12/32 to B12/33

Schemes: pages B12/34 to B12/37

Combination for customer assembly: pages B12/38 to B12/41

B12/8