low loss 67 material for high frequency power applications...high frequency power applications...

23
Low Loss 67 Material for High Frequency Power Applications Presented by: Fair-Rite Products Corporation APEC 2016 Rachael Parker & Michael Arasim

Upload: others

Post on 10-Mar-2021

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Low Loss 67 Material for High Frequency Power Applications

Presented by: Fair-Rite Products Corporation

APEC 2016 Rachael Parker & Michael Arasim

Page 2: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Low Loss 67 Material for High Frequency Power Applications

• The development of high frequency switching power converters has driven the need for low loss magnetic materials.

• Due to the lack of material performance data, the design of power magnetic components for high frequency operation (2-20 MHz) has been difficult to achieve.

• This presentation will review the intrinsic material characteristics (such as power loss density & useable flux density) in low permeability NiZn ferrites and will focus on Fair-Rite type 67 material.

Page 3: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Agenda

• Market Motivation

• Classic methods for estimating Performance Factor

• New Test method – “Resonant Q”

• Performance data 67 and other Fair-Rite materials

Page 4: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Market Motivation

• Miniaturization is a driving force in electronics design. – Magnetics are typically the largest component in

power supplies.

• In order to minimize power supply footprints, operating frequency has been increasing. – Power loss of magnetic components

incorporated into these designs can cause issues with efficiency and heat management.

Page 5: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Limitations of Permeability

• µ’ and µ’’ curves are shown at low flux densities. – Measured at ≈ 0.1 mT

• Not reliable for power supply designs which operate at higher flux densities, but this is currently the only metric available at higher frequencies (f > 10 MHz).

Losses (µ’’) become

unacceptable above

50 MHz.

Page 6: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Current Testing Methods • Until recently, methods of testing power

materials at higher frequencies have been expensive and/or unreliable. – Clark Hess has been the industry standard test

method for materials up to 1MHz. – Current systems rely on phase angle, which at higher

frequencies is difficult to measure accurately. • “As the phase angle θ becomes close to 90°, the

measurement accuracy of the core loss Pc becomes worse.” – Iwatsu Electric Co.

• Only measures up to 10MHz.

Page 7: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

New Measurement Method • Fair-Rite utilizes the “resonant Q” method developed by MIT to conduct

measurements. – This system has been replicated at Fair-Rite with MIT’s assistance.

• This method removes the reliance on phase angle as part of the measurement.

(1) Han, Y; Cheung, G; Li, A; Sullivan, C.R.; Perreault, D.J.; “Evaluation of Magnetic Materials for Very High Frequency Power Applications” in Power Electronics, IEEE Transactions on , vol. 27, no.1, pp.425-435

Page 8: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Calculations • Peak Flux Density1:

• Power Loss Density2:

Definitions fs = resonant frequency C = resonant capacitor value µr = relative permeability µ0 = permittivity of free space N = number of turns on inductor core do = outer diameter of inductor core di = inner diameter of inductor core Vout-pk = peak output voltage IL-pk = peak current through inductor VL = inductor core volume L = inductance of core Vin-pk = peak input voltage Rc = resistance of resonant capacitor Rcu = resistance of copper winding

(2) Hanson, A.J.; Belk, J.A.; Lim, S.; Perreault, D.J.; Sullivan, C.R., "Measurements and performance factor comparisons of magnetic materials at high frequency," in Energy Conversion Congress and Exposition (ECCE), 2015 IEEE , vol., no., pp.5657-5666, 20-24 Sept. 2015

Page 9: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

HF Power Loss Curves @ 25C

• Typical power loss curves (Power Loss vs. Flux Density) provided at higher frequencies.

10

100

1000

1 10 100

Pv (mW/cm3)

B (mT)

67 Power Loss Density vs. Flux Density at 25oC

2MHz

5MHz

7MHz

10MHz

15MHz

20MHz

Measured on a 22.1mm/13.7mm/6.35mm toroid at 25o C.

500mW/cm3

Page 10: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

HF Power Loss Curves @ 25C

• Typical power loss curves (Power Loss vs. Flux Density) provided at higher frequencies.

10

100

1000

1 10 100

Pv (mW/cm3)

B (mT)

61 Power Loss Density vs. Flux Density at 25oC

2MHz

5MHz

7MHz

10MHz

15MHz

20MHz

Measured on a 18.8mm/10.2mm/6.3mm toroid at 25 C.

500mW/cm3

Page 11: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

HF Power Loss Curves @ 100C

10

100

1000

1 10 100

Pv (mW/cm3)

B (mT)

67 Power Loss Density vs. Flux Density at 100oC

2MHz

5MHz

7MHz

10MHz

15MHz

20MHz

Measured on a 22.1mm/13.7mm/6.35mm toroid at100o C.

500mW/cm3

• Typical power loss curves (Power Loss vs. Flux Density) provided at higher frequencies.

Page 12: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

What is “Performance Factor”?

• Represents the maximum flux density at a specific power loss density

– Power loss density used for measurements = 500 mW/CC

• “It is defined as the maximum product of peak flux density and frequency as a function of frequency at a constant power loss density”

• “Soft Ferrites: A User’s Guide” © 1992 by Magnetics Materials Producers Association

Page 13: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Data from MIT2

Fair-Rite’s 67 material performs very well compared to other tested materials.

Page 14: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Operating temperature comparison

• Similar competitor material has a higher power loss density under the same test conditions as compared to Fair-Rite’s 67 material. – Test conditions: 12mT 10 MHz

The competition Fair-Rite’s 67

Page 15: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Power Loss vs. Temperature

• Fair-Rite’s 67 material is reasonably stable over temperature.

0

200

400

600

800

0 20 40 60 80 100 120

Pv (mW/cm3)

Temperature(oC)

67 Power Loss Density vs. Temperature

2MHz, 20mT

5MHz, 15mT

10MHz, 10mT

15MHz, 7.5mT

Measured on a 22.1mm/13.7mm/6.35mm toroid .

Page 16: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Performance Factor Curves for different size cores

• Optimal operating frequency decreases as core size increases

0

25

50

75

100

125

150

175

200

1 10 100

Bf

Frequency (MHz)

Performance Factor

5967000201 0.17cm^3

5967001801 1.50cm^3

5967002701 7.33cm^3

5967003801 24.50cm^3

Page 17: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Peak Performance Frequency vs. Core Size

• Want to operate where performance factor is highest, but smaller cores cannot handle as high a power level.

R² = 0.9932

0

10

20

30

0 5 10 15 20 25

Vo

lum

e(c

m^

3)

Frequency (MHz)

With the size of electronics shrinking, operating frequency

has been increasing in order to minimize

power supply footprints.

Page 18: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Design Considerations

• 67 material is a perminvar material, meaning that strong magnetic fields or excessive mechanical stresses may result in irreversible changes in permeability and losses.

• Benefits of a permivar material are:

– Flatter temperature response

– Higher Curie temperature

– Lower losses out to higher frequencies.

Page 19: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Affect on Permeability

1

10

100

1,000,000 10,000,000 100,000,000 1,000,000,000

ms'ms''

Frequency Hz

5967001101 after varying levels of B at 10MHz

Initial

After B 22 mT

After B 25 mT

ms'

ms''

Losses at low flux densities increases after exposure to B = 25mT @ 10MHZ.

Page 20: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Affect on Power Loss

1

10

100

1000

10000

1 10 100

Pv(mW/cm3)

B (mT)

5967001101 10MHz Power Loss Densityvs. Flux Density at 25C

Initial

After B 22mT

After B 25mT

Measured on a 12.7mm/7.9mm/6.35mm toroid at 25o C.

Once core is exposed to B of 25mT @ 10 MHz, power loss irreversibly increases.

Page 21: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Whapping Threshold

• At lower frequencies, a higher B is needed to “whap” the part. • At higher frequencies, a lower B will “whap” the part.

1

10

100

1 10 100

B mT

Frequency (MHz)

67 Material

300mw/cm^3

500mw/cm^3

Whapped

Measured on a 12.7mm/7.9mm/6.35mm toroid at 25o C.

Page 22: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Effects of DC Bias

• If part is exposed to a DC bias that is too high, there is a noticeable and irreversible change to the losses.

0

1

10

100

1,000,000 10,000,000 100,000,000 1,000,000,000

ms'ms''

Frequency Hz

5967001101 after increasing levels of Hdc(A/m)

Initial

After H=480A/m

After H=640A/m

After H=800A/m

ms'

ms''

0

1

10

100

1,000,000 10,000,000 100,000,000 1,000,000,000

ms'ms''

Frequency Hz

5967001101 at increasing levels of Hdc(A/m)

Initial

H=480A/m

H=640A/m

H=800A/m

ms'

ms''

During DC bias exposure After DC bias exposure

Page 23: Low Loss 67 Material for High Frequency Power Applications...High Frequency Power Applications •The development of high frequency switching power converters has driven the need for

Thank you!

• Visit us at booth #1842. • Stay current on our latest developments at Fair-Rite.com