C) SITE TO BE CLEARED OF EXISTING GARAGE AND SHED, AND ANY ASSOCIATED STRUCTURAL ELEMENTS U c- -r 66 555 demolish existing gar ge and shed Lot 5 DP 22129 1011m° 66 545 demolision PLAN CHECK SITE FOR ASBESTOS BEFORE WORK BEGINS, IF PRESENT IT SHOULD BE REMOVED BY A QUALIFIED ASBESTOS REMOVALIST. c DEMOLITION TO BE CARRIED OUT IN ACCORDANCE WITH AS2601-2001 DEMOLITION OF STRUCTURES and THE SAFE WORK AUSTRALIA DEMOLITION CODE OF PRACTICE LOCATE ALL GAS, ELECTRIC, SEWER, STORMWATER AND WATER LINES BEFORE WORK BEGINS PLANS/ DA/ WEBSTER/ VERSION 1/ 29 NOVEMBER 2019 www.dialbeforeyoudig.com.au e Di L fio kJ au son raw as D1 These drawi ngs are copyright and may not be reproduced in any form wi thout the writt en AMENDMENTS % Karen Gay NSW Reg 3819 PROJ ECT Proposed Unit Development SCALE permiss ion of Design West Arc hitect s and De si gners. Do not scale from Drawi ngs. If in doubt ask DESIGN WEST 1:200 These drawi ngs are to be read in their entirety, it is forbidden to reproduce them in part. - Nominated Architect --- -- - CLI ENT Check all sizes bef ore wo rk begins. Check all levels on site before work begins. - ABN 21 003 908 038 J Webster DATE 29/11/19 An y discrepanci es are to be referred to this offi ce at once. Al l materials and workmanship MEMBER Architecture 44 Macquarie Street, Cowra NSW 2794 - JOB No are to be in strict acco rdance wi th current manuf act urers printed instructions, local regulations, The Aus t-t ar Ph. (02) 63 423 230 Fax (02) 63 424 792 LOCATI ON 161 Bathurst Road, Orange 122/07 The Building Code of Au stralia and SAA Codes. Fix foam seals and weatherstri ps to all ext ernal doors. lnsti bJll!of An:hitlldll -

Upload: others

Post on 14-Mar-2022

3 views

Category:

Documents


0 download

TRANSCRIPT

C) SITE TO BE CLEARED OF EXISTING GARAGE AND SHED, AND ANY ASSOCIATED STRUCTURAL ELEMENTS

U

c-

-r

66 555

demolish existing gar ge and shed Lot 5 DP 22129 1011m°

66 545

demolision PLAN CHECK SITE FOR ASBESTOS BEFORE WORK BEGINS, IF PRESENT IT SHOULD BE REMOVED BY A QUALIFIED

ASBESTOS REMOVALIST.

c DEMOLITION TO BE CARRIED OUT IN ACCORDANCE WITH

AS2601-2001 DEMOLITION OF STRUCTURES and THE SAFE WORK AUSTRALIA DEMOLITION CODE OF PRACTICE

LOCATE ALL GAS, ELECTRIC, SEWER, STORMWATER AND WATER LINES BEFORE WORK BEGINS

PLANS/ DA/ WEBSTER/ VERSION 1/ 29 NOVEMBER 2019

www.dialbeforeyoudig.com.au

e DiL fio kJ au son raw as D1 These drawings are copyright and may not be reproduced in any form without the written AMENDMENTS % Karen Gay NSW Reg 3819 PROJECT Proposed Unit Development SCALE permission of Design West Architects and Designers. Do not scale from Drawings. If in doubt ask DESIGN WEST 1:200 These drawings are to be read in their entirety, it is forbidden to reproduce them in part. - Nominated Architect

--- -- - CLIENT Check all sizes before work begins. Check all levels on site before work begins. - ABN 21 003 908 038 J Webster DATE 29/11/19 Any discrepancies are to be referred to this office at once. All materials and workmanship

MEMBER Architecture 44 Macquarie Street, Cowra NSW 2794 - JOB No are to be in strict accordance with current manufacturers printed instructions, local regulations, The Aus t-tar Ph. (02) 63 423 230 Fax (02) 63 424 792 LOCATION 161 Bathurst Road, Orange 122/07 The Building Code of Australia and SAA Codes. Fix foam seals and weatherstrips to all external doors. lnstibJll!ofAn:hitlldll -

44 650 __ - _ap_~ro~

5500 5465 - cos

a

C>

V)

a::

Lot 5 DP 22129 1011m'

CD

driveway

!

site PLAN , UNIT FOOTPRINT AREAS - 84.35m

house open space 54.9m'

5325-approx

66555

------ 21004 } ?

I

- - #

7 '4 ~,L / 7

1 II c::-- ' I I I

¢ l

] 's c

open space 578m2

' =! 8 I ""! I 8 I

L I 66 545

5000 3000

7000

manouevering area driveway g ~. ' visitor parking

t_ju/

open space 60.7m2

0005667160 08 Feb 2021 . .,,.,, caret or

ABSA

10000 3375 3375 3000

1585-approx 15485 - ppro 43415-approx I

+

a bmstore ·z:..-­ ?m high deciduous 1

C>

a::

V)

a::

CD

EXISTING PLANTING RETAINED IN THIS AREA

Lot 5 DP 22129 1011m'

EXISTING 1500 HIGH FENCE

driveway reint concrete

MATCH EXISTING 66 555 - REPLACE EXISTING FENCE AS NECESSARY WITH 1800 HIGH FENCE TO

0

½ N H O U S

EXISTING 1500 HIGH FENCE

1500highcolorbondfence

Kikuyu turf

driveway reinf concrete

low planting so«o no-;;;g,

s K « ht [k . ' ·,

reinfcomrete

1500 high colorbond fence

manouevering area

NOTES

PROJECT

ed Unit Development Propes

CLIEN~T~---------

J Webster LOCATION

161 Bathurst Road Orange DATE SCALE

landscape PLAN CALLISTEMON CITRINUS - Crimson bottle Brush 1 to3mhigh

66545 - EXISTING 1800 HIGH COLORBOND FENCE 1800highcolorbondfente CALLISTEP10N rnR1Nuhs

- Crimson Bottle~rus 3 to 3m evergreen

112/21

r nasiev wssr ;;,'w;' Architecture _,._ KanilnGayNSWReg3819

NominateclAlt:hllecl ABN 21 003 908 ~ 2794

«s";Teer Ph. (02} 63 423 230 ax

107/19

1.100

Job Number. v 2021 WEBSTER/ VERSION 3 / 1 FEBRUAR PLANS/DA/

Lysaght (ustom Orb roofing- co lorbond Lysaght (ustom Orb roofing- colorbond Lysaght Custom Orb roofing - colorbond Lysaght Custom Orb roofing - colorbond Lysaght(usto1nOrbroofing-colorbond

co lorbonjl gutter and fascia ~5!P sue colorbond gutter

and fasoa

driveway slab

j

~1 colorbond f~nre i laundry door aluminium sliding window entry door

concrete path selected weatherboard ne elevation claddmg through car port

Lysaght Custom Orb roofing- co(orbond

aluminium sliding window

ne elevation

selected weatherboard cladding

Lysaght (us tom Orb roofing- colorbond Lysaght Custom Orb roofing - colorbond Lysaght (ustom Orb roofing - colorbond Lysaght Custom Orb roofing - rnlorbond

colorbond gutter and fascia

driweway slab ®-- ---, --

' • entry door I aluminium sliding window laundry SW elevation selectedweathecboa,d through car port claddlag

Lysaght Custom Orb roofing- colorbond sarking

70x35F5(treated)roofbatte.~s \

prefab timber roof trusses {treated) @i max 600 centre\ \

\ \

colorbondgutter and fascia

typical section

ROOFING ROOF BA TT ENS ROOF SARKING ROOF TRUSSES CEILING INSULATION CEILING EXTERNAL WALLS

INTERNAL WALLS STUD WALLS

WALL SARKING WALL INSULATION LINING CLADDING FLOOR SLAB UNDERBUILDING FDDTINGS

ridge cap

6oo]

««reg!

z

selected weatherboard aluminium sliding window cladding

sw elevation

I plasterboard ceiling {z;mead

I ~ ~

booada,polocboadfeme 12~0 600

9

afcoacslab living tnb,/::::•~:~,'(,~:;;::1

90 600

'6JS-CDS -~---:,. boundarycolorbondflmce R25all batts _. «wre" ± ] """ _ «ms

e t

'L7

Construction Schedule Wind Classification N2

Lysaght Custom Orb roofing - colorbond 70035 F5 battens @ max 900 centres Sisalation Pre fab treated timber roof trusses @ max 600 centres R35insulation above ceiling 10mm plasterboard 90mm timber stud walls constructed as below min 60/60/60 fire rated masonry wall between car ports 90mm timber stud walls constructed as below AU stud walls to be constructed in accordance with AS 1684.2- 2010 Residential Timber Framed Construction ( Non.(yrloflic Areas) Sisalation R25 all batts 10mm plasterboard selected weatherboard by engineer by engineer by engineer

Wet areas, Vil!aboard or Wet Area Plasterboard

Note, All brickwork to be constructed to AS3700-2011 (SAA Masonary Code) All structural timberwork and al! structural bracing and liedo,..ns to comply with AS 1684- 2010 Residential Timber Framed Construction (Non.Cyclonir Areas) Termite proofing to be to AS 3660.1-2000

All structural steelwork and all structura( bracing and tiedowns to comply with Part 3.4.2 STEEL FRAMING

frcsoffit

window schedule Number Type Opening Size h xl

UT1 ALUMINIUM DH WINDOW 1500 1800 ALUMINIUM DH WINDOW 1500 1800 ALUMINIUM SLIDING WINDOW 600x1500 ALUMINIUM SLIDING WINDOW 1200 1800 ALUMINIUM SLIDING WINDOW 900 1500 ALUMINIUM SLIDING WINDOW 900,:900 ALUMINIUM SLIDING WINDOW 600 1800

D ALUMINIUM GLAZED ENTRY DOOR AND SIDELIGHTS 2100x1700

UNIT 2 ALUMINIUM OH WINDOW 1500 1800 ALUMINIUM DH WINDOW 1500 1 1800

10 ALUMINIUM SLIDING WINDOW 600 1500 11 ALUMINIUM SLIDING WINDOW 1200 1800 12 ALUMINIUM SLIDING WINDOW 900 1500 13 ALUMINIUM SLIDING WINDOW 900 900 14 ALUMINIUM SLIDING WINDOW 600 1800 D2 ALUMINIUM GLAZED ENTRY

DOOR ANO SIDELIGHTS 21001700 Note Windows to be powder coated in colour chosen by owner Windows and doors tobe fitted with suitable insect screens Al! windows single glazed unless specified

SEE Nat HERS CERTIFICA IT FOR GLAZING (OltHITt1ENTS

Orientation

NW NW SW SW SE SE NE

NW NW NE NE SE SE SW

W

colorbond fence selected weatherboard aluminium dh window cladding

nw elevation aluminium dh window

selected weatherboard cladding aluminium sliding window

se elevation

Basix Compliance Schedule - Unit 1

Site Details SITE AREA RDDF AREA

1011m2

135 9m

selected weatherboilrd selected weatherboard cladding 60/60/60 fire rated wall cladding

to underside of roofing

' seleded weatherboard selected weatherboard cdadding an 60/60/60 fire rtd at cladding

to underside of roofing

Water Commitments SHOW£RHEADS 3 sfilr ( .. 7 5 but .. :9 OL/m) TOILET FLUSHING SYSTEM 3 star KICHEN TAPS 3 star BATHROOM BASIN TAPS 3star

Alternative water supply Rainwater tank with a capacity of 2500 Litres to be installed on site This water tank must meet. and be installed in accordance with relevant Australian standards and all applicable regulatory authorities

ROOF AREA TO BE COLLECTED 135 9m " ROOF AREA DIVERTED TO TANK 100% SIZE OF RAINWATER TANK 2500 L GARDEN AREA 59.85m2

RAINWATER TO CONNECT TO ·ALL TOILETS IN THE DEVELOPMENT ·COLD WATER TAPS SUPPLYING CLOTHES WASHERS IN THE DEVELOPMENT

Energy Commitments HOT WATER

·GAS INSTANTANEOUS - MIN 5.5STARS

HEATJNG/(OQLING SYSTEM ·INSTALLED SYSTEM TO BE 1PHASE AIR-COND1TIONING - 35 ST AR ENERGY RA TING •TO HEAT ALL LIVING AREAS •TO COOL BEDROOMS INSTALL CEILING FANS

entry door I aluminiumdh window

selected weatherboard aluminium sliding window ladding

Basix Compliance Schedule - Unit 2

Site Details SITE AREA ROOF AREA

1011m 135.9m

selected weatherboard cladding

Water Commitments SHOWE RHEADS 3star 6»75 but«=9.0L/ml TOILET FLUSHING SYSTEM 3 star Kl[HEN TAPS 3star BATHROOM BASIN TAPS 3 star

Alternative water supply Rainwater tank with a capacity of 2500 Litres to be installed on site This water tank must 1t1eet. and be installed in accordance with relevant Australian standards and all applicable regulatory authorities

ROOF AREA TO BE COLLECTED 135.9m ROOF AREA DIVERTED TO TANK 100X

SIZE OF RAINWATER TANK 2500 L GARDEN AREA 60.7m2

RAINWATER TO CONNECT TO ·ALL TOILETS IN THE DEVELOPMENT •COLD WATER TAPS SUPPLYING CLOTHES WASHERS IN THE DEVELOPMENT

Energy Commitments HOTWATER

+GAS INST ANTANEOUS - MIN 55ST AAS

HE A TING/COOLING SYSTEM INSTALLED SYSTEM TO BE 1PHASE AIR-CONDITIONING ­ 35 STAR ENERGY RATING

• TO HEAT All LIVING AREAS • TO COOL BEDROOMS INST ALL CEILING FANS

aluminium dh window

VENTILATION VENTILATION •MECHANICAL VENTILATION REQUIRED IN KITCHEN, LAUNDRY ANO BATHROOM •MECHANICAL VENTILATION REQUIRED IN KITCHEN. LAUNDRY ANO BATHROOM SEE BASIX CERTIFICATE SH BASIX CERTIFICATE ALL EXTERNAL DOORS TO BE FITTED WITH ORAUGH7 STOPPERS •All EXTERNAL DOORS TO BE FITTED WITH DRAUGHT STOPPERS INC. INTERNAL ODORS TO GARAGE INC. INTERNAL DOORS TO GARAGE

LIGHTING PRIMARY TYPE OF LIGHTING - FLUORESCENT OR LIGHT EMITTING DIODE (LEO} •All LIVING ANO DINING ROOMS ·ALL BEDROOMS/STUDY •All BATHROOMS. TOILETS ANO KITCHEN ·ALL HALLWAYS ANO LAUNDRY

OTHER •ENERGY EFF![ENT GAS COOKTOP AND ELECTRIC OVEN -WELL VENTILATED REFRIGERATOR SPACE ­ TO BAS!X REQUIREMENTS •INST ALL A FIXED COVERED CLOTHES LINE

LIGHTING •PRIMARY TYPE OF LIGHTING - FLUORESCENT OR LIGHT EMITTING DIODE (LED) •ALL LIVING ANO DINING ROOMS ·ALL BEDROOMS/STUDY ·ALL BATHROOMS, TOILETS AND KITCHEN ·ALL HALLWAYS AND LAUNDRY

OTHER •ENERGY EFFICENT GAS COOKTOP ANO ELECTRIC OVEN ·WELL VENTILATED REFRIGERATOR SPACE ­ TO BASIX REQUIREMENTS .INSTALL A FIXED COVERED CLOTHES LINE

g 1111

0005667160 08 Feb 2021

ABSA"

G

vwdottboeroko ii Vii

2 NOTES Th go0opt4otb owlet woof Degele0Dgr

Dedo tore Defir. hie tori0po.or Cc leg Ch. kb ""ewe AMENDMENTS Amdt Date Descri ption A 25/212.0 Fire wall added B 1/2/21 Unit width reduced

PROJECT

Thermal Comfort Commitments CONDITIONED AREA UNCONDITIONED AREA

Thermal Comfort Commitments 6B.9m2

1a CONDITIONED AREA UNCONDITIONED AREA

Proposed Unit Development CLIENT

J Webster LOCATION

161 Bathurst Road Orange DATE SCALE

112121 1:100, 1:50 £. el2N. ±ii±;

DESIGN WEST Architecture

68.9m2

11m

Karen Gery NSW Reg 3819 NominaledArchlted ABN 21 003 906 038

« Macquarie Strel!lt, Co.,-e NSW 2794 Ph. (02) 63 423 230 FBX {02) 63 424 792

Job Number: 107/19 PLANS/ DA/ WEBSTER/ VERSION 3/1FEBRUARY 2021

>

0 < 0 O 0 0 co

RIDGE

• 6000

6000 0/A I FRAME ROOF PLAN

:I s)

I

I

I

I

I

8

ELEVATION GRID B z I

0 ELEVATION GRID 2 ) s)

I

ELEVATION GRID A ELEVATION GRID 1

Copyright 2021 Lysaght Building Solutions Pty Ltd

trading as RANBUILD Better sheds. Bigger choice.

CLADDING ITEM PROFILE (min) FINISH COLOUR ROOF CUSTOM ORB 0.42 BMT CB cc WALLS -

CORNERS - CB cc BARGE - CB cc GUTTER HI-QUAD CB cc

DOWNPIPE 100x50 CB cc

0.35bmt=0.40tct; 0.42bmt=0.4 7tct; 0.48bmt=0.53tct

ACCESSORY SCHEDULE & LEGEND QTY MARK DESCRIPTION

ARCHITECTURAL DRAWING ONLY, NOT FOR CONSTRUCTION USE

WIND DESIGN IMPORTANCE LEVEL REGION TERRAIN Ms

2 A 2 1.0

CLIENT lachlan steel SITE

young rd COWRA NSW 2794

BUILDING

GABLE CARPORT 3000 SPAN x 2400 EAVE x 6000 LONG

TITLE

GENERAL ARRANGEMENT

SCALE DRAWING NUMBER REV PAGE A4 SHEET 1:125 COWR01-1938 A 1/1