Linking the futureAs the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy and information as a primary driver in the development of communities.
With this in mind, we provide major global organisations in many industries with best-in-class cable solutions, based on state-of-the-art technology. Through three renowned commercial brands – Prysmian, Draka and General Cable – based in almost 50 countries, we‘re constantly close to our customers, enabling them to further develop the world‘s energy and telecoms infrastructures, and achieve sustainable, profitable growth.
In our energy business, we design, produce, distribute and install cables and systems for the transmission and distribution of power at low, medium, high and extra-high voltage.
In telecoms, the Group is a leading manufacturer of all types of copper and fibre cables, systems and accessories – covering voice, video and data transmission.
Drawing on over 130 years‘ experience and continuously investing in R&D, we apply excellence, understanding and integrity to everything we do, meeting and exceeding the precise needs of our customers across all continents, at the same time shaping the evolution of our industry.
2 www.prysmiangroup.ro
IntroductionFor more than a decade we have produced power cords under the brand of Eurelectric. Since the beginning we’ve sourced top-quality materials from trusted vendors to create power cords for use in industrial, commercial and home applications. And to be able to satisfy all our clients’ needs, we immediately focused on areas such as product development, improvement of the manufacturing processes and customization of products. As a result, our reputation as a world leading manufacturer within the energy and telecommunication cable industries has extended to our power cords under the brand of Prysmian Group as well.
ApplicationOur power cords have unique performance skills. You can drag them, bend them, pull them and roll them. And you’ll still have outstanding cords with no flaws and ready to set your device in motion.
At Prysmian Group we offer a wide range of products, including power cords with PVC flex cables, harmonized rubber cables and other customer tailored solutions. Our portfolio is completed with single wires specially designed for OEM applications.
We make thorough and recurring test on all our cables to make sure they are safe for domestic appliances as well as industrial applications. That’s why we can stand behind our products with complete confidence.
Prysmian Group power cords will fit your appliances perfectly.No matter if it’s a washing machine, power tool or industrial appliance, our power cords will be the perfect fit. With the highest quality performance, longer service life than comparable products on the market and the ability to tailor the cords to your specific requirements, you can rest assured they’ll fill the shoes. Finally, to convince you that our offer truly is an ideal match to yours, all power cords and cables are KEMA KEUR and HAR certified. Try it on!
ContentsMade in Slatina 4
A responsible approach 5
HAR Certification 6
Powercords 7H05V-K 8H07V-K 8H03VV-F 9H05VV-F 9H03V2V2-F 10H05V2V2-F 10H05RN-F 11H07RN-F 11H05RR-F 12
Plug inserts 13Plug 1610 14Plug 1622 15Plug 1630 16Plug 1669 17Plug 1668 18Plug 1664 19Plug 1683 20Connector 2254 21
Tailored to your requirements 22
Committed to quality 23
3www.prysmiangroup.ro
Made in Europe.From the deepest oceans and mines to the farthest satellites orbiting Earth in Space, you’ll find products made by us. In Eastern Europe, in the beautiful Romanian city of Slatina, you’ll find one of Europe’s largest power cable plants. Here our skilled colleagues are manufacturing tons of state-of-the-art cables every year. Prysmian Romania is a proud part of the world’s largest global actor in the cable manufacturing business – Prysmian Group. But, no matter how large we are, we live and expand thanks to you, our local customers and business partners. We know what you need and can make the cables meet the quality demands that you ask for because we appreciate the importance of understanding local preconditions and your special needs. That’s why we thought it was crucial to extend our range of products to power cords as well and have the production based in Europe. This way we can deliver the cables where and when you need them, lowering transport distances, saving money and protecting the environment. It is a win-win, for all of us.
4 www.prysmiangroup.ro
A responsible approach.Being the largest cable manufacturer in the world we understand and embrace our responsibility towards both people and the planet we are living on. That’s why all Prysmian Group cables are certified according to important directives and regulations.
RoHSA directive against the use of six different hazardous materials: lead, mercury, cadmium, chromium, PPBs and PBDEs.
REACHA regulation requiring all companies manufacturing or importing chemical substances into EU to communicate these substances throughout the supply chain.
5www.prysmiangroup.ro
HAR Certification.All our cables are licensed according to HAR. The HAR Certification is the best possible assurance regarding the quality and compliance of the certified products. To pass through the eye of the needle, a number of product samples are tested and must be approved. And, to maintain the validity of the licence, a stringent programme of tests is carried out on a yearly basis.
Designation HAR
Example
Symbol for specification H: harmonized specification H
Nominal voltage03: 300/300 V05: 300/500 V07: 450/750 V
05
Insulation material
V: PVC (70 ̊ C)V2: PVC (90 ̊ C)R: natural and/or styrene butadienne rubberB: Rubber (90 ̊ C)Z1: halogen-free thermoplastic compounds
V
Outer sheath material
V: PVC (70 ̊ C)V2: PVC (90 ̊ C)R: natural and/or styrene butadienne rubberN: polychropene rubber (60 ̊ C)B: Rubber (90 ̊ C)N4: polychloroprene (90 ̊ C)Z1: halogen-free thermoplastic compounds
V
Particularities in constructionH: flat, separable cableH2: flat, non-separable cable
Type of conductor
U: single-coreR: multicoreK: fine wire for cables at solid installationF: fine wire for flexible cablesH: extra fine wire for flexible cablesY: tinsel cord
F
Number of coresG: with protective conductorX: without protective conductor
Core cross section 0,5 to 6 mm2 **
Certifications HAR
* Please contact us for non standard requirement.** According to cable type.
6 www.prysmiangroup.ro
Powercords
7www.prysmiangroup.ro
H05V-K
H07V-K
Cable characteristics
Rated voltage 300/500 V
Test voltage 2000 V
Max. conductor temp in continuos duty
70 °C
Max temp of conductor in short-circuit for max. 5 s
160 °C
Min. instalation temp. +5 °C
Standards/Certifications/ Approvals
EN 50525EN 50525-2-31HARCE
Conductor material Stranded copper class 5
Insulation material PVC type TI1
Number of cores 1
Conductor color Code1-core: black, white, grey, brown, blue, green/yellow, red; others acc. to the agreement
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
Cable characteristics
Rated voltage 450/750 V
Test voltage 2500 V
Max. conductor temp in continuos duty
70 °C
Max temp of conductor in short-circuit for max. 5 s
160 °C
Min. instalation temp. +5 °C
Standards/Certifications/ Approvals w
EN 50525EN 50525-2-31HARCE
Conductor material Stranded copper class 5
Insulation material PVC type TI1
Number of cores 1
Conductor color Code1-core: black, white, grey, brown, blue, green/yellow, red; others acc. to the agreement
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
1x0,5 2.1 - 2.5 8.6
1x0,75 2.2 - 2.7 10.99
1x1 2.4 2.8 13.78
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
1x0,5 2.1 - 2.29 9.74
1x1,5 2.8 - 3.4 19.79
1x2,5 3.4 - 4.1 30
8 www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Cable characteristics
Rated voltage 300/300 V
Test voltage 2000 V
Max. conductor temp in continuos duty
70 °C
Max temp of conductor in short-circuit for max. 5 s
160 °C
Min. instalation temp. -5 °C
Standards/Certifications/ Approvals w
EN 50525EN 50525-2-11HARIEC 60227CE
Conductor material Stranded copper class 5
Insulation material PVC type TI2
Number of cores 2-3
Conductor color Code
2-core: blue, brown3-core: blue, brown, yellow/green
*3-core: blue, brown, black*3-core: brown, black, grey
Sheathing material, colorPVC type TM2; standard colors: white, grey, black
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
*On request.
Cable characteristics
Rated voltage 300/500 V
Test voltage 2000 V
Max. conductor temp in continuos duty
70 °C
Max temp of conductor in short-circuit for max. 5 s
160 °C
Min. instalation temp. -5 °C
Standards/Certifications/ Approvals w
EN 50525EN 50525-2-11HARIEC 60227CE
Conductor material Stranded copper class 5
Insulation material PVC type TI2
Number of cores 2-5
Conductor color Code
2-core: blue, brown3-core: blue, brown, yellow/green
*3-core: blue, brown, black*3-core: brown, black, grey 4-core: brown, black, grey, yellow/green
*4-core: blue, brown, black, yellow/green*4-core: blue, brown, black, grey 5-core: blue, brown, black, grey, yellow/green
Sheathing material, colorPVC type TM2; standard colors: white, grey, black
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
*On request.
H03VV-F
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
2x0,5 5.00 36.28
2x0,75 5.30 46
3G0,5 5.30 42.76
3G0,75 5.50 50.34
H05VV-F
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
2x0,75 5.95 53.92
2x1 6.30 60
2x1,5 7.20 80
2x2,5 8.90 124
2x4 10.10 170
3G0,75 6.35 63.82
3G1 6.75 74.08
3G1,5 8.05 105.03
3G2,5 9.60 155
3G4 10.90 215
4G0,75 6.80 73
4G1 7.50 89
4G1,5 8.80 126
4G2,5 10.50 189
4G4 11.90 264
5G0,75 8.20 108
5G1 8.80 123
5G1,5 10.30 177
5G2,5 12.30 262
5G4 14.30 358
9www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
H03V2V2-F
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
2x0,75 6.2 57
2x1 6.6 66
2x1,5 7.7 94
3G0,75 6.6 68
3G1 7.1 78
3G1,5 8.3 118
3G2,5 10.1 182
3G4 11.6 248
4G0,75 7.3 82
4G1 8 108
4G1,5 9.3 149
4G2,5 11.1 2260
4G4 12.7 323
5G0,75 8.2 108
5G1 8.8 123
5G1,5 10.3 177
5G2,5 12.3 262
5G4 14.3 358
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
2x0,5 5.1 35
2x0,75 5.2 40
3G0,5 5.4 46
3G0,75 5.5 50.1
H05V2V2-F
Cable characteristics
Rated voltage 300/300 V
Test voltage 2000 V
Max. conductor temp in continuos duty
90 °C
Max temp of conductor in short-circuit for max. 5 s
150 °C
Min. instalation temp. -5 °C
Standards/Certifications/ Approvals w
EN 50525EN 50525-2-11HD 383EN 60228HARIEC 60227CE
Conductor material Stranded copper class 5
Insulation material PVC type TI3
Number of cores 2-3
Conductor color Code
2-core: blue, brown3-core: blue, brown, yellow/green
*3-core: blue, brown, black*3-core: brown, black, grey
Sheathing material, colorPVC type TM3; standard colors: white, grey, black
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
*On request.
Cable characteristics
Rated voltage 300/500 V
Test voltage 2000 V
Max. conductor temp in continuos duty
90 °C
Max temp of conductor in short-circuit for max. 5 s
150 °C
Min. instalation temp. -5 °C
Standards/Certifications/ Approvals w
EN 50525EN 50525-2-11HD 383EN 60228HARIEC 60227CE
Conductor material Stranded copper class 5
Insulation material PVC type TI3
Number of cores 2-5
Conductor color Code
2-core: blue, brown3-core: blue, brown, yellow/green
*3-core: blue, brown, black*3-core: brown, black, grey4-core: brown, black, grey, yellow/green
*4-core: blue, brown, black, yellow/green*4-core: blue, brown, black, grey5-core: blue, brown, black, grey, yellow/green
Sheathing material, colorPVC type TM3; standard colors: white, grey, black
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
*On request.
10 www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
H05RN-F
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
2x0,75 6.1 51
2x1 6.6 61
3G0,75 6.6 63
3G1 6.9 73
4G0,75 7.2 77
4G1 7.5 89
Cable characteristics
Rated voltage 300/500 V
Test voltage 2000 V
Max. conductor temp in continuos duty
60 °C
Max temp of conductor in short-circuit for max. 5 s
250 °C
Min. instalation temp. -25 °C
Standards/Certifications/ Approvals w
EN 50525-2-21CE
Conductor material Stranded copper class 5
Insulation materialVulcanized rubber compound, type EI4; standard color: black
Number of cores 2-4
Conductor color Code
2-core: blue, brown3-core: blue, brown, yellow/green
*3-core: blue, brown, black*3-core: brown, black, grey4-core: brown, black, grey, yellow/green
*4-core: blue, brown, black, yellow/green*4-core: blue, brown, black, grey
Sheathing material, colorVulcanized rubber compound, type EI4; standard color: black
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
*On request.
H07RN-F
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
1x1,5 5.9 49
1x2,5 6.5 65
1x4 7.4 89
1x6 8.2 115
2x1,0 8.1 87
2x1,5 9.4 118
2x2,5 11.2 172
2x4 13 238
2x6 13.7 285
3G1.0 8.8 105
3G1,5 9.8 134
3G2,5 11.5 192
3G4 13.2 267
3G6 14.7 351
4G1,0 9.7 130
4G1,5 10.7 166
4G2,5 12.6 240
4G4 14.5 235
4G6 16.3 448
5G1,0 10.7 159
5G1,5 11.8 -201
5G2,5 13.8 290
5G4 16.2 412
5G6 18.2 550
Cable characteristics
Rated voltage 450/750 V
Test voltage 2500 V
Max. conductor temp in continuos duty
60 °C
Max temp of conductor in short-circuit for max. 5 s
250 °C
Min. instalation temp. -25 °C
Standards/Certifications/ Approvals w
EN 50525-2-21CE
Conductor material Stranded copper class 5
Insulation materialVulcanized rubber compound, type EI4
Number of cores 1-5
Conductor color Code
1-core: black2-core: blue, brown3-core: blue, brown, yellow/green
*3-core: blue, brown, black*3-core: brown, black, grey4-core: brown, black, grey, yellow/green
*4-core: blue, brown, black, yellow/green*4-core: blue, brown, black, grey5-core: blue, brown, black, grey, yellow/green
Sheathing material, colorVulcanized rubber compound, type EI4; standard color: black
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
*On request.
11www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Nominal area (conductor no.xsection)
mm2
Approx. diameter mm2
Approx. weightkg/km
2x0,75 6.2 53
2x1 6.7 63
2x1,5 8.2 94
2x2,5 9.6 134
2x4 11.2 190
3G0,75 6.7 65
3G1,0 7 75
3G1,5 8.7 111
3G2,5 10.2 161
3G4 11.9 231
3G6 13.4 311
4G0,75 7.3 79
4G1,0 7.6 92
4G1,5 9.6 141
4G2,5 11.3 204
4G4 13.2 295
4G6 14.8 397
5G0,75 8.1 98
5G1,0 8.5 115
5G1,5 10.5 169
5G2,5 12.5 252
5G4 14.7 361
H05RR-F Cable characteristics
Rated voltage 300/500 V
Test voltage 2000 V
Max. conductor temp in continuos duty
60 °C
Max temp of conductor in short-circuit for max. 5 s
250 °C
Min. instalation temp. -25 °C
Standards/Certifications/ Approvals w
EN 50575EN 50525-2-21CE
Conductor material Stranded copper class 5
Insulation materialVulcanized rubber compound, type EI4
Number of cores 2-5
Conductor color Code
2-core: blue, brown3-core: blue, brown, yellow/green
*3-core: blue, brown, black*3-core: brown, black, grey4-core: brown, black, grey, yellow/green
*4-core: blue, brown, black, yellow/green*4-core: blue, brown, black, grey5-core: blue, brown, black, grey, yellow/green
Sheathing material, colorVulcanized rubber compound, type EM3; standard color: black
Lead free Yes
Reaction to fire EN 60332-1-2
RoHS/REACH compliant Yes
*On request.
12 www.prysmiangroup.ro
Plug inserts
13www.prysmiangroup.ro
Plug 1610
Une marque de
FT N
°895
Fic
he 16
10 10
16 A
250V
Bip
olai
re +
Ter
re -
V1 F
év. 2
014
Petit électroménagerHousehold appliances
Matériel InformatiqueInformation technology
Gros électroménagerWhite Goods
1933
32 19
10 38
Ø4.8
Fiche / Plug 1610Fiche 16 A/250V Bipolaire + TerrePlug 16 A/250V Bipolar + GroundIEC 60884-1 (Ed. 3 / third edition)NF C 61314, Feuille / sheet 5
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Fiche équipée du double système de mise à la terre médian et latéral. Pour les appareils de la Classe 1.
Two-pole plug with double earthing system. Safety class 1.
Option• Coque double isolation
Option• Double insulation shell
Caractéristiques dimensionnelles Dimensional characteristics
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACH
Directive 2011/65/UE
Dimensional characteristics
Certification
All our power cords are KEMA-KEUR certified.
Two-pole plug with double earthing system. Safety class 1. 16 A/250 V Bipolar + Ground.
Standard
IEC 60884-1:2002 + A1:2006 + A2:2013 NEN 1020:1987 + A2:2004
14 www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Certification
All our power cords are KEMA-KEUR certified.
Plug 1622
Dimensional characteristics
3 pin overmoulded plug for UK market. Fused. 13 A/250 V.
Standard
To be updated.
Une marque de
FT N
°896
Fic
hes
1620
1621
13 A
250V
- V2
Sep
t. 2
013
Petit électroménagerHousehold appliances
LuminairesLight
Matériel InformatiqueInformation technology
Outillage Electro-portatif Portable electrical tools
Gros électroménagerWhite Goods
TV / Vidéo TV / Video
4
17,7
8
22,72
6,35
4
22,24
22,24
25
49
44,5
75
Fiches / Plugs 1620 et / and 1621Fiches 13 A/250VPlugs 13 A/250VStandard BS 1363-1
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACH
Directive 2011/65/UE
Fiches surmoulées 3 broches pour câble bipolaire ou tripolaire. Fusible intégré. Destiné au Royaume-Uni.
3 pin overmoulded plugs for UK market. Fused.
Caractéristiques dimensionnelles Dimensional characteristics
15www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Plug 1630
Two-pole plug with double earthing system. Safety class I. 16 A/250 V Bipolar + Ground. Plug splash proof – IP44.
Standard
IEC 60884-1:2002 + A1:2006 + A2:2013 NEN 1020:1987 + A2:2004
Dimensional characteristics
Une marque de
FT N
°899
Fic
he 16
30 -
V3 O
ct. 2
014
68,9
� 42�4,8
19
19
18,3 4,6
32
Fiche / Plug 1630Fiche 16 A/250V IPX4 Bipolaire + Terre Plug 16 A/250V IPX4 Bipolar + GroundNorme CEE 7, feuillet / sheet VII
IEC 60884-1 (Ed. 3 / third edition)
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACHREACHREACHREACH
Directive 2011/65/UE
Fiche goutte d’eau IPX4 équipée du double système de mise à la terre médian et latéral. Pour les appareils de classe I. Option : coque double isolation.
Plug splash proof (IPX4). Two-pole plug with double earthing system. Safety class I. Option : double insulation shell.
Caractéristiques dimensionnelles Dimensional characteristics
Outillage Electro-portatif Portable electrical tools
Certification
All our power cords are KEMA-KEUR certified.
16 www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Plug 1669
Une marque de
FT N
°862
Fic
he 16
69 -
V1 F
év. 2
014
� 42
�4,8
58,8
18,3 4,6
19
19
32
Fiche / Plug 1669Fiche 16 A/250V IPX4 / Plug 16 A/250V IPX4Norme CEE 7, feuillet / sheet XVII
IEC 60884-1 (Ed. 3 / third edition)
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACH
Directive 2011/65/UE
Fiche goutte d’eau IPX4. Pour appareils de la classe II. Pour équipements isolés.Sortie de câble droite (axiale).
Plug splash proof (IPX4). Safety class II.Only allowed for insulated apparatus.Straight plug.
Caractéristiques dimensionnelles Dimensional characteristics
Petit électroménagerHousehold appliances
Outillage Electro-portatif Portable electrical tools
Dimensional characteristics
Two-pole plug. Safety class II. 16 A/250 V Bipolar Plug splash proof – IP44.
Standard
IEC 60884-1:2002 + A1:2006 + A2:2013 NEN 1020:1987 + A2:2004
Certification
All our power cords are KEMA-KEUR certified.
17www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Plug 1668
Dimensional characteristics
Cordset with straight plug for heavy duty purpose. Safety class II.16 A/250 V
Standard
IEC 60884-1:2002 + A1:2006 + A2:2013 NEN 1020:1987 + A2:2004
Une marque de
FT N
°897
Fic
he 16
68 10
16 A
250V
- V
1 Fé
v. 2
014
Outillage Electro-portatif Portable electrical tools
19
32
36.5
Ø4.8
1010
4.2
19
Fiche / Plug 1668Fiche 16 A/250VStraight plug 16 A/250VIEC 60884-1 (Ed. 3 / third edition)
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Pour les appareils de la classe II. Selon Norme CEE 7, feuille XVII.Cordon à usage professionnel.
Safety class II. Manufacturing specifications : CEE 7 sheet XVII. Cordset for heavy duty purpose.
Caractéristiques dimensionnelles Dimensional characteristics
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACH
Directive 2011/65/UE
Une marque de
FT N
°898
Fic
he 16
64 10
16 A
250V
Bip
olai
re -
V1 D
éc. 2
012
Petit électroménagerHousehold appliances
Outillage Electro-portatif Portable electrical tools
19
52 32
Ø4.8
19
Fiche / Plug 1664Fiche 16 A/250V BipolaireStraight plug 16 A/250V BipolarIEC 60884-1 (Ed. 3 / third edition)
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Pour les appareils de la classe II. Selon Norme CEE 7, feuille XVII. Sortie de câble droite (axiale).
Safety class II. Only allowed for insulated apparatus.Manufactoring specifications : CEE 7, sheet XVII.Straight plug.
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACH
Directive 2011/65/UE
Caractéristiques dimensionnelles Dimensional characteristics
Certification
All our power cords are KEMA-KEUR certified.
18 www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Plug 1664
Straight plug allowed for insulated apparatus. Safety class II. 16 A/250 V Bipolar.
Standard
IEC 60884-1:2002 + A1:2006 + A2:2013 NEN 1020:1987 + A2:2004
Une marque de
FT N
°898
Fic
he 16
64 10
16 A
250V
Bip
olai
re -
V1 D
éc. 2
012
Petit électroménagerHousehold appliances
Outillage Electro-portatif Portable electrical tools
19
52 32
Ø4.8
19
Fiche / Plug 1664Fiche 16 A/250V BipolaireStraight plug 16 A/250V BipolarIEC 60884-1 (Ed. 3 / third edition)
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Pour les appareils de la classe II. Selon Norme CEE 7, feuille XVII. Sortie de câble droite (axiale).
Safety class II. Only allowed for insulated apparatus.Manufactoring specifications : CEE 7, sheet XVII.Straight plug.
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACH
Directive 2011/65/UE
Caractéristiques dimensionnelles Dimensional characteristicsDimensional characteristics
Certification
All our power cords are KEMA-KEUR certified.
19www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Plug 1683
Une marque de
FT N
°866
Fic
he 16
83 -
V2 N
ov. 2
014
Petit électroménagerHousehold appliances
LuminairesLight
TV / Vidéo TV / Video
17- 01+
5,55°
19 � 0,5 40
11,9
35,5
13,2
8,3
4Ø5
Fiche / Plug 1683Fiche 2,5 A / 250 V Bipolaire Plug 2,5 A/ 250 V BipolarNF EN 50075
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/2
compliantREACHREACHREACHREACH
Directive 2011/65/UE
Fiche plate bipolaire pour appareils de classe II. Flat two-pole plug. Safety class II.
Caractéristiques dimensionnelles Dimensional characteristicsDimensional characteristics
Flat two-pole plug. Safety class II. 2,5 A/250 V Bipolar.
Certification
All our power cords are KEMA-KEUR certified.
20 www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Connector 2254
Dimensional characteristics
Connector two-pole plug. Safety class II. 2,5 A/250 V Bipolar.
Une marque de
FT N
°867
Con
nect
eur /
Con
nect
or 12
54 -
V1 F
év. 2
014
LuminairesLight
TV / Vidéo TV / Video
57
18
16,7
9,5
7,9
12
8,55
9,9
16
R4,95
© PRYSMIAN 2012. Tous droits réservés. Il est interdit de copier, photocopier ou reproduire les informations contenues dans ce document dans quelque forme que ce soit, même en partie sans l’accord écrit préalable de Prysmian. Les informations sont communiquées à titre indicatif, Prysmian se réservant le droit de modifier les caractéristiques du produit sans préavis.
© PRYSMIAN 2012. All Rights Reserved. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian. The information is believed correct at the time of issue. Prysmian reserves the right to amend this specification without notice. This specification is not contractually valid unless specifically authorised by Prysmian.
Connecteur / Connector 2254Connecteur 2,5 A / 250 V Bipolaire Connector 2,5 A/ 250 V BipolarIEC 60320
Basse Tension (BT) - Low Voltage (LV)Domestique Souple - Domestic Flexible
Prysmian Group Service commercial / Sales department - Tél. : +33 (0)4 72 46 73 99 - mail : [email protected] www.eurelectric.fr
1/1
compliantREACH
Directive 2011/65/UE
Connecteur bipolaire pour appareils de classe II. Connector two-pole plug. Safety class II.
Caractéristiques dimensionnelles Dimensional characteristics
H03 VVH2-F 2 x 0,75 √
Homologations Certificats
Certification
All our power cords are KEMA-KEUR certified.
21www.prysmiangroup.ro
Technical data, dimensions and w
eights are subject to change.
Tailored to your requirements.All our power cords and cables are available in a tremendous variety of configurations, giving you plenty of options to configure your own products.
• Power cord Part number + amperage rating
• Plug insert Plug insert type construction – solid pin, plastic filled hollow pin, hollow pin
• Cable Type-color-length sq size and N° Conductor
• Strain relief Part number position, pull-test (based on customer specifications)
• Female end Specification for slitting and termination (table 2)
1. Power cord specification
2. Female end terminating
L
L
L
L’
L
L
L
L’
L
L
L
L’
Cables 2 conductors
Cables 3 conductors
Cables 3 unequal conductors
Stripping
Barrel termination
Autoband without insulating crimp
Barrel termination with insulation support
Crimp terminal
Ring terminal
Spade terminal
3. Packing options
How to package your products is only a question about what you prefer. We have the ability to adapt and customise the packaging to your specific needs.
ISO 9001:2015 Quality Management Systems
ISO 14001:2015 Environmental Management Systems
OHSAS 18001:2007 Assessment Specification for Occupational Health & Safety Management Systems
Welcome to the latest edition of the Technical Cable Guide.
Following the recent acquisition of Draka, the Prysmian Group is now the world’s largest producer of power and telecommunication cables with 97 manufacturing plants, 17 Research & Development Centres, and around 22,000 employees.
A global solutions provider, Prysmian o�ers a wide range of integrated solutions, such as cable systems, system design and engineering, project management, installation and postsale services.
Prysmian focuses on continuous product innovation and on achieving a competitive edge by focusing on research and development. This is done through Prysmian’s own research & development centres and by co-operating with universities, scientific institutions and our valued customers. Prysmian’s world-wide organisation makes and delivers advanced technological solutions to customers anywhere in the world.
Prysmian is committed to providing all of the necessary technical, installation, safety and practical information that may be required by designers, installers and users of our products in a comprehensive hand book that can easily be used in the field.
Please accept this latest edition of the Technical Cable Guide with our compliments.
Prysmian Cables & Systems Australia Pty Ltd proudly manufactures in Australia and operates certified management systems compliant with the requirements of;
ISO 9001:2000 Quality Management Systems AS/NZS 4801:2001 Occupational Health & Safety Management SystemsOHSAS 18001:1999 Assessment Specification for Occupational Health & Safety Management SystemsISO 14001:2004 Environmental Management Systems
22 www.prysmiangroup.ro
COMMITTED TO QUALITY
Production adapted to customer values and needs.
“Manufacturing is the soul of our company and plants are our heart. We were born to produce. And our world-leading reputation is the result of a truly customer-centric approach based on reliability.”Andrea Pirondini COO, Prysmian Group
At our plants in Slatina, Romania, we provide customers and communities worldwide with energy and telecom cable solutions based on state-of-the-art technology, consistent excellence in execution and in-depth understanding of the needs of an evolving market.
As we are in control of our manufacturing process, we are able to perform advanced tests to make sure that all cables leaving our plants maintain the highest quality and comply to all relevant standards
– may it concern safety, durability, performance or sustainability.
Do you want to know more? Visit our website: www.prysmiangroup.ro
© A
ll rights reserved by Prysmian Group 20
19-10 | Version 1.
Prysmian Group
Offices RomaniaStrada Dragănești, nr. 28, Slatina, 230119Phone: +40 249 406 600E-mail: [email protected]
Disclaimer:
Technical data, dimensions and weights are subject to change. All sizes and values without tolerances are reference values. Specifications are for product as supplied by Prysmian Group: any modification or alteration afterwards of product may give different result. The information contained within this document must not be copied, reprinted or reproduced in any form, either wholly or in part, without the written consent of Prysmian Group. The information is believed to be correct at the time of issue. Prysmian Group reserves the right to amend this specification without prior notice. This specification is not contractually valid unless specifically authorized by Prysmian Group.
Linking the future