longitude

1
Longitude Latitude A recent analysis of the Fermi-LAT data by M. Su et al. [1] revealed two large spherical structures centered by our Galactic Center and perpendicular to the galactic plane, the so called Fermi Bubbles. These structures are characterized by gamma emission with a hard and uniform spectrum and a relatively constant intensity all over the space. According to R.M. Crocker and F. Aharonian [2] the reason of the emission in region of the Fermi Bubbles can be hadronic acceleration and the proton spectrum should have almost flat E -2 shape with some cutoff (probably around 1 PeV as suggested in the paper). According to the recipe of F. Vissani [3] neutrino flux from gamma flux was estimated as: Φ υ ~ 0.4 Φ γ E 2 υ /dE=1.2*10 -7 GeV cm -2 s -1 sr -1 Cutoff for neutrino ~ 1/20 cutoff CR x υ = 50 TeV-500 TeV Shape reported by M. Su et al. was approximated according to figure on the right in galactic coordinates. The ratios are compatible with 1 in all cases inside the statistical error. There could be a systematic effect due to the different visibilities of the zones. Therefore a conservative systematic error of 3% has been considered as the average difference from 1 of the data ratios. This error was taken into account in the final analysis, where number of events in ON zone was compared to <OFF> zone (average number of events). OFF/ON zones approach The Fermi Bubbles are extended but limited regions in the sky. Their sky-coverage corresponds to approximately 0.8sr. In order to estimate the background in the Fermi Bubbles zone one can use another zone in the sky with same sky coverage and same visibility of the Fermi Bubbles (FB) zone. Such zone (OFF zone) can be defined considering a zone in the sky that corresponds to the FB zone (ON zone) after a certain shift in time. Obviously the OFF zone should not overlap with the FB zone. In galactic coordinates the OFF zone will be fixed in the sky, while in local coordinates , it will follow the FB zone as time passes. On the right plot the position of the Fermi Bubbles in local coordinates is shown at a specific time during the day (black filled region). The OFF zone (red filled region) corresponds to the Fermi Bubbles zone after a negative shift of 6 hours. The dotted lines (black for Fermi Bubbles and red for the OFF zone) show the position of the two zones in previous 2 hours. In this analysis 3 OFF zones were considered that correspond to time shift of 6, 12 and 18 hours in respect to the ON zone. Figure on the left below shows in galactic coordinates the position of the ON zone and of the 3 OFF zones together with the visibility of the ANTARES detector. ANTARES telescope The ANTARES detector[4] is large neutrino telescope that aims to detect high energy neutrinos coming from astrophysical sources. It consists of 12 lines of photomultipliers positioned at 2475 m deep in the Mediterranean sea. When a neutrino arrives close to the detector it can interact producing a high energy muon. The Cherenkov light produced by the muon in the water can be detected by the ANTARES photomultipliers. The main background is due to atmospheric muons produced by interaction of cosmic rays in the atmosphere. This background can be reduced by looking at upward going tracks. In this preliminary analysis data from 2007-2010 with low bioluminescence conditions were used (~169 days with uncompleted detector configuration and ~419 with a detector composed of 9-12 lines). The main parameters used in this analysis are: Nlines: number of detector lines used in the fit Λ: reconstruction quality parameter (the range of Λ goes from -8 for badly reconstructed events to -4 for good ones) NHits: number of hits of the reconstructed track β: angular error of reconstructed track A preliminary cut (Λ>-6, Nhits>60, β< 1 o ) has been defined to check that number of events in 3 OFF zones are comparable. The ratios of the number of events after the preliminary cut between the OFF zones in data and Monte Carlo (MC) are presented in table below. For the final cut obtained number of events in the ON zone was compared with an average between OFF zones. The plot for Nhits distribution is presented on the right above. In Total 90±5(stat) ±3 (syst) events in <OFF> zone as background and 75±9 for the signal were observed. Obtained values of number of events in ON zone and <OFF zone> were used to calculate upper limit with 90% C.L. using Gaussian distribution for the background (including systematics) and Poisson distribution for signal according to method explained by T.Rolke et al. [6]. Finally upper limit fluxes according to the MC were estimated. The systematic error for data/MC comparison is +15% -6%. As the final upper limit flux an estimated limit plus mentioned systematic is presented. Flux upper limits from this analysis are compared with expected fluxes from the Fermi Bubbles for different cutoffs. Fluxes and table summarizing results are shown below. Current preliminary analysis due to a negative statistical fluctuation in the ON zone can exclude the expected flux levels for some very optimistic cutoffs (no cutoff and 500 TeV cutoff). V. Kulikovskiy on behalf of the ANTARES collaboration. [email protected]. it (INFN Genova / MSU) μ cutoff (TeV) MRF A MRF no cutoff 2.75 3.30 500 3.79 4.55 100 5.74 6.89 50 7.58 9.09 cutoff (TeV) N_events in MC A upper syst. errors no cutoff 5.4 0.68 0.04 -0.09 500 3.9 0.94 0.06 -0.12 100 2.6 1.41 0.09 -0.18 50 1.9 1.93 0.12 -0.25 Preliminary search for neutrino emission from the Fermi Bubbles with the ANTARES telescope Final cuts for the data according to Model Rejection Factor with 90% C.L. were optimized using G. Feldman and R. Cousins recipe [5]. Precut was: Nlines> 1 β< 1 o Nhits and Λ cut were left as free parameters. Optimization was done on the 3 OFF zones in MC adding to them signal with the flux E 2 υ /dE=1.2*10 -7 GeV cm -2 s -1 sr -1 and cutoff 100 TeV. Table summarizing results and MRF for different cutoffs is presented on the right. Presented MRF flux corresponds to E 2 υ /dE=A MRF *10 -7 GeV cm -2 s -1 sr - 1 . It also was found that minimum MRF for different cuttoffs is lower than obtained MRFs on the table by at maximum 20%. A data/MC comparison for the final cuts is shown below. Final flux limits (E 2 υ /dE=A upper *10 -7 GeV cm -2 s -1 sr -1 ) References [1] M. Su, T.R.Slatyer, D.P.Finkbeiner, arxiv:1005.5480v3 [2] R.M. Crocker, F. Aharonian, Phys.Rev.Lett. 106 (2011) 101102 [3] F.L. Villante, F. Vissani, Phys. Rev. D 78 (2008) 103007 [4] The ANTARES collaboration, NIMA 656 (2011) 11-38 [5] G.J. Feldman, R.D. Cousins, Phys.Rev. D 57 (1998) p3873-3889 [6] W.Rolke, A. Lopez, J. Conrad, F. James NIMA 551 (2005) 493-503 This is a preliminary analysis. Future analysis will have following improvements: more sophisticated energy estimator + higher bioluminescence data + 2011 data Ratio of events in OFF zones data MC 1 to 2 0.97±0.04 0.97±0.07 2 to 3 0.98±0.04 1.12±0.07 3 to 1 1.05±0.04 0.92±0.07 ON <OFF> data atm υ MC atm υ+μ MC FB υ no cutoff MC FB υ 500 TeV MC FB υ 500 TeV MC FB υ 500 TeV MC data atm υ MC atm υ+μ MC FB υ no cutoff MC FB υ 500 TeV MC FB υ 500 TeV MC FB υ 500 TeV MC PRELIMINARY dotted – expected fluxes solid upper limits 50 TeV cutoff 100 TeV cutoff 500 TeV cutoff no cutoff Acknowledgments. This work was done thanks to the ANTARES collaboration which has proven a possibility of undersea neutrino telescope realization. Thanks to M.Anghinolfi, H.Costantini, C.Riviere, M.Vecchi, J.P.Ernenwein, M.Spurio, A. Kouchner whose help was invaluable for analysis.

Upload: kimo

Post on 23-Feb-2016

35 views

Category:

Documents


0 download

DESCRIPTION

Preliminary search for neutrino emission from the Fermi Bubbles with the ANTARES telescope. V. Kulikovskiy on behal f of the ANTARES collaboration. [email protected] . it (INFN Genova / MSU). Latitude. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Longitude

Longitude

Latit

ude

A recent analysis of the Fermi-LAT data by M. Su et al. [1] revealed two large spherical structures centered by our Galactic Center and perpendicular to the galactic plane, the so called Fermi Bubbles. These structures are characterized by gamma emission with a hard and uniform spectrum and a relatively constant intensity all over the space. According to R.M. Crocker and F. Aharonian [2] the reason of the emission in region of the Fermi Bubbles can be hadronic acceleration and the proton spectrum should have almost flat E-2 shape with some cutoff (probably around 1 PeV as suggested in the paper). According to the recipe of F. Vissani [3] neutrino flux from gamma flux was estimated as:• Φυ ~ 0.4 Φγ E2dΦυ/dE=1.2*10-7 GeV cm-2s-1 sr-1

• Cutoff for neutrino ~ 1/20 cutoff CR xυ = 50 TeV-500 TeVShape reported by M. Su et al. was approximated according to figure on the right in galactic coordinates.

The ratios are compatible with 1 in all cases inside the statistical error. There could be a systematic effect due to the different visibilities of the zones. Therefore a conservative systematic error of 3% has been considered as the average difference from 1 of the data ratios. This error was taken into account in the final analysis, where number of events in ON zone was compared to <OFF> zone (average number of events).

OFF/ON zones approach

The Fermi Bubbles are extended but limited regions in the sky. Their sky-coverage corresponds to approximately 0.8sr. In order to estimate the background in the Fermi Bubbles zone one can use another zone in the sky with same sky coverage and same visibility of the Fermi Bubbles (FB) zone. Such zone (OFF zone) can be defined considering a zone in the sky that corresponds to the FB zone (ON zone) after a certain shift in time. Obviously the OFF zone should not overlap with the FB zone. In galactic coordinates the OFF zone will be fixed in the sky, while in local coordinates , it will follow the FB zone as time passes. On the right plot the position of the Fermi Bubbles in local coordinates is shown at a specific time during the day (black filled region). The OFF zone (red filled region) corresponds to the Fermi Bubbles zone after a negative shift of 6 hours. The dotted lines (black for Fermi Bubbles and red for the OFF zone) show the position of the two zones in previous 2 hours. In this analysis 3 OFF zones were considered that correspond to time shift of 6, 12 and 18 hours in respect to the ON zone. Figure on the left below shows in galactic coordinates the position of the ON zone and of the 3 OFF zones together with the visibility of the ANTARES detector.

ANTARES telescope

The ANTARES detector[4] is large neutrino telescope that aims to detect high energy neutrinos coming from astrophysical sources. It consists of 12 lines of photomultipliers positioned at 2475 m deep in the Mediterranean sea. When a neutrino arrives close to the detector it can interact producing a high energy muon. The Cherenkov light produced by the muon in the water can be detected by the ANTARES photomultipliers.The main background is due to atmospheric muons produced by interaction of cosmic rays in the atmosphere. This background can be reduced by looking at upward going tracks.In this preliminary analysis data from 2007-2010 with low bioluminescence conditions were used (~169 days with uncompleted detector configuration and ~419 with a detector composed of 9-12 lines).

The main parameters used in this analysis are:• Nlines: number of detector lines used in the fit • Λ: reconstruction quality parameter (the range of Λ goes from -8 for badly reconstructed events to -4 for good ones)• NHits: number of hits of the reconstructed track• β: angular error of reconstructed track A preliminary cut (Λ>-6, Nhits>60, β< 1o) has been defined to check that number of events in 3 OFF zones are comparable. The ratios of the number of events after the preliminary cut between the OFF zones in data and Monte Carlo (MC) are presented in table below.

For the final cut obtained number of events in the ON zone was compared with an average between OFF zones. The plot for Nhits distribution is presented on the right above. In Total 90±5(stat) ±3 (syst) events in <OFF> zone as background and 75±9 for the signal were observed.Obtained values of number of events in ON zone and <OFF zone> were used to calculate upper limit with 90% C.L. using Gaussian distribution for the background (including systematics) and Poisson distribution for signal according to method explained by T.Rolke et al. [6]. Finally upper limit fluxes according to the MC were estimated. The systematic error for data/MC comparison is +15% -6%. As the final upper limit flux an estimated limit plus mentioned systematic is presented.Flux upper limits from this analysis are compared with expected fluxes from the Fermi Bubbles for different cutoffs. Fluxes and table summarizing results are shown below. Current preliminary analysis due to a negative statistical fluctuation in the ON zone can exclude the expected flux levels for some very optimistic cutoffs (no cutoff and 500 TeV cutoff).

V. Kulikovskiy on behalf of the ANTARES [email protected]. it (INFN Genova / MSU)

μ

cutoff (TeV) MRF AMRF

no cutoff 2.75 3.30

500 3.79 4.55

100 5.74 6.89

50 7.58 9.09

cutoff (TeV) N_events in MC Aupper syst. errorsno cutoff 5.4 0.68 0.04 -0.09

500 3.9 0.94 0.06 -0.12100 2.6 1.41 0.09 -0.1850 1.9 1.93 0.12 -0.25

Preliminary search for neutrino emission from the Fermi Bubbles with the ANTARES telescope

Final cuts for the data according to Model Rejection Factor with 90% C.L. were optimized using G. Feldman and R. Cousins recipe [5]. Precut was:• Nlines> 1• β< 1o

Nhits and Λ cut were left as free parameters. Optimization was done on the 3 OFF zones in MC adding to them signal with the flux E2dΦυ/dE=1.2*10-7 GeV cm-2s-1 sr-1 and cutoff 100 TeV. Table summarizing results and MRF for different cutoffs is presented on the right. Presented MRF flux corresponds to E2dΦυ/dE=AMRF*10-7 GeV cm-2s-1 sr-1 . It also was found that minimum MRF for different cuttoffs is lower than obtained MRFs on the table by at maximum 20%.A data/MC comparison for the final cuts is shown below.

Final flux limits (E2dΦυ/dE=Aupper*10-7 GeV cm-2s-1 sr-1 )

References[1] M. Su, T.R.Slatyer, D.P.Finkbeiner, arxiv:1005.5480v3[2] R.M. Crocker, F. Aharonian, Phys.Rev.Lett. 106 (2011) 101102[3] F.L. Villante, F. Vissani, Phys. Rev. D 78 (2008) 103007[4] The ANTARES collaboration, NIMA 656 (2011) 11-38[5] G.J. Feldman, R.D. Cousins, Phys.Rev. D 57 (1998) p3873-3889[6] W.Rolke, A. Lopez, J. Conrad, F. James NIMA 551 (2005) 493-503

This is a preliminary analysis. Future analysis will have following improvements:

• more sophisticated energy estimator• + higher bioluminescence data

• + 2011 data

Ratio of events in OFF

zonesdata MC

1 to 2 0.97±0.04 0.97±0.07

2 to 3 0.98±0.04 1.12±0.07

3 to 1 1.05±0.04 0.92±0.07

ON<OFF>

data

atm υ MCatm υ+μ MC

FB υ no cutoff MCFB υ 500 TeV MCFB υ 500 TeV MCFB υ 500 TeV MC

data

atm υ MCatm υ+μ MC

FB υ no cutoff MCFB υ 500 TeV MCFB υ 500 TeV MCFB υ 500 TeV MC

PRELIMINARYdotted – expected fluxessolid – upper limits

50 TeV cutoff100 TeV cutoff500 TeV cutoff

no cutoff

Acknowledgments. This work was done thanks to the ANTARES collaboration which has proven a possibility of undersea neutrino telescope realization. Thanks to M.Anghinolfi, H.Costantini, C.Riviere, M.Vecchi, J.P.Ernenwein, M.Spurio, A. Kouchner whose help was invaluable for analysis.