Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan Anderberg. National Renewable Energy Laboratory Golden, CO USA Sunday, August 10, 2008 NREL/PR-520-43838 Presented at the Society of Photo Optical Engineers’ (SPIE) Optics+Photonics conference held August 10-14, 2008 in San Diego, California.

Upload: others

Post on 24-Sep-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Long-Term Performance Data and Analysis of CIS/CIGS Modules

Deployed OutdoorsJ. A. del Cueto, B. Kroposki, S. Rummel, Allan Anderberg.

National Renewable Energy Laboratory Golden, CO USA

Sunday, August 10, 2008

NREL/PR-520-43838Presented at the Society of Photo Optical Engineers’ (SPIE) Optics+Photonics conferenceheld August 10-14, 2008 in San Diego, California.

Page 2: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Outline Introduction Rationale for thin-film CIS PV modules: cost - high efficiency Identify loss modes and/or sources in CIS/CIGS modules

Module deployment &Tests at NREL OTF two manufacturers, types ‘A’ & ‘B’, on 3 separate testbeds

Analyses 2 types of data, STC & dark I-V standard diode devices Real-time field data analysis

Conclusions FF degradation is predominant loss modeType ‘A’ can show very low rate to moderate loss rates

Series-resistance increases symptomatic of A modulesType ‘B’ can show very low loss rate to nominal loss rate

Shunt increases & other subtle changes or failure mechanisms

Transient behavior observed especially after dark storage

Page 3: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Introduction Thin-film PV technologies (CIGS, CdTe, a-Si/nc-Si) are expected

to achieve and compete for lowest cost per watt vs. bulk technologies (c-Si, poly-c-Si) largely because of economy in and costs of semiconductor materials usage;

Copper indium diselenide (CIS) and/or gallium-alloyed CIGS photovoltaic (PV) modules achieve some of highest PV conversion efficiency of the thin-films: Current state-of-the-art CIGS efficiency at Standard Test

Conditions (STC): cells attain 19.9% modules ( ~ 0.4 - 0.5 m2) attain ~12%

CIGS PV module stability issues need addressing issues under damp/dry heat exposure high-voltage bias applications for electrical power

Page 4: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Introduction: performance & reliability loss modes FF losses:Series resistance (Rse) increases: degradation of top TCO (ZnO) resistivity CdS/CIS interface

Shunt conductance (Gsh) Diode qualities (A, J0) & recombination

Voc losses:electronic carrier effects in CIS,band offsets,CdS/CIS interface

Isc loss modes not obvious, but possibilities: transparency of top TCO, EVARse increases are very large

Page 5: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Experimental Tests at OTF Two manufacturers of modules ‘A’ & ‘B’ glass/Mo/CIGS/CdS/ZnO/glass laminates type A deployed beginning in 1988, 5 vintages type B deployment began 2002 Other CIS manufacturers also at OTF but not reported

Study CIS/CIGS modules deployed on 3 testbeds: Single units, free-standing, long-term exposure, loaded at

Pmax (STC) with fixed resistor, 9 total High Voltage Stress Testbed (HVST2) Array consists of 2, bipolar strings, nominally ± 300 VDC open circuit12 type ‘A’ CIGS modules per string, 24 totalI-V traces monitored & loaded continuously with DAS

Performance & Energy Ratings Testbed (PERT)I-V traces monitored & loaded continuously with DASA module 1997, B module 2002

Page 6: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

PERT & HVST2 Array Module Deployment Performance & Energy Ratings Testbed

(PERT) Open-air steel frame mounts, face due

south, tilted at 40° latitude with respect to horizontal

Meteorologic resources (Irr, module & air temps., etc)

Array: High-voltage stress test (HVST2) Same sensors as PERT, plus RH Elevated, frames electrically floated

to measure HV leakage currents

PERT: viewed looking west

HVST2 array: viewed looking east

Page 7: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Long-term free-standing single module deployment

loaded with fixed resistor, 9 modules totalAlso tilted at latitude angle,

facing southopen-air steel rack mounts

Long-term exposure rack seen looking east1988 A module installed 20 years

Page 8: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Data Analysis: STC or dark at 25°C Single I-V curves at STC or dark at 25°CSTC data: SPIRE, LACSS or SOMS LACSS & SOMS use P/S to drive I-V traces

Module data normalized to unit area cell (J-V): dividing voltage by series cell count (Ncell) dividing current by area per cell (Acell = AperArea / Ncell)

Standard PV device diode circuit model with parasitic series resistance (Rse) and shunt conductance (Gsh) determined Rse, Gsh (dark) allows raw data to be corrected

and then to derive A, J0

Page 9: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Diode Analysis: Rse, diode Q, Gsh, J0 Diode Eq. Derive 3-pnt slopes dV/dJ

(Rse) or dJ/dV (Gsh) & correct data for series & shuntdV/dJ vs. 1/J or 1/(J+Jlight)

Intercept = Rse, slope = A (kBT/q)

Gsh: from dJ/dV minimum near 0 V

V –> Vcor = V -RseJ, J –> Jcor = J - GV

Ln(Jcor)-Vcor => J0, Also A => slope V vs. LnJ

J = J0 * [ eq(V-RseJ)/AkT - 1 ] + GSHV - JL

dV/d

J (O

hm-c

m2 )

0

5

10

15

20

25

1/J (cm2/A)0 100 200 300 400 500

V (volts)

Ln[J

] (m

A/c

m2)

0.0 0.1 0.2 0.3 0.4 0.5 0.6

MeasuredCorrected

10-6

10+2

10-4

10-2

100

Page 10: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Data Analysis: PERT & HVST2 Real-time outdoor data measured in situ with

programmable electronic loads & DASI-V power parameters (Voc, FF, etc.) data condensedsegregated into narrow irradiance bands (±25 W/m2) for all

illumination intensities, Linear regression vs. module temperature (Tmod) each bin:

Parameter Y: Y(Tmod) = Y0 + dY/dTmod * Tmod

select bands analyzed 250, 500, 1000 W/m2, vs. timeaveraged to cover 3 select windows for ±75 W/m2 span cover most of energy-producing field conditions

Data partitioned to 3-month intervalsPower parameters, Rseries, diode Q factor derived for eachChanges in power parameters vs. time calculate

Page 11: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Single module data at STC (SPIRE or LACSS) Manufacturers A & B: A: (5 vintages) 1988, 1990, 1992,

1994, 1998; B: 2002

A module initial efficiency from 8% (1988) to ~ 11-12% (1998) Low loss rates earlier 1%/yr or less stability became issue when initial

efficiency exceeded ~ 9%: FF losses account for most declineVoc increases in initial years, partly

offset FF losses, but subsequently can degrade

B module initial efficiency ~11% slight decline mostly in FF, partly

offset by Voc increase during first years 1/88 1/90 1/92 1/94 1/96 1/98 1/00 1/02 1/04 1/06 1/08

Effi

cien

cy (%

)FF

(%)

Voc

(V)

B M

odul

esA

Mod

ules

Voc

(V)

50515253

222324252627

Taken out of service

45505560

6570

56789

101112

1988 A1990 A1992 A1994 A

1997 A1998 A2002 B

1988 A1990 A1992 A1994 A

1997 A1998 A2002 B

Changein SPIRE

Page 12: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Data: series resistance changes single modulesDark & Light Slopes dV/dJ plotted vs. 1/J for dark data read along lower

ordinate axis 1/(J+JLight) for light data, read along

upper ordinate axis 2002 B in upper pane (‘02, ‘05, ’08)

1998 A in lower pane (‘99, ‘02, ’07) For 2002 B no increase in Rse

intercept in both dark & light data over timecurvature suggestive of other effects

For 1998 A substantial increase in Rse intercept in dark (~ 4 Ω-cm2) & some in light (1-2 Ω-cm2) data with time

1/J (cm 2/A)

dV/d

J (Ω

-cm

2 )

0

5

10

15

20

25

CIS B: 2002

Lit-08

Lit-02Lit-05Drk-05

Drk-02

Drk-08

0 100 200 300 400

01002003004001/[J + JL] (cm2/A)

CIS A: 1998

dV/

dJ (Ω

-cm

2 )

0

5

10

15

20

251/[J + JL] (cm2/A)

0 100 200 300 4001/J (cm2/A)

Lit-99Lit-02Lit-07

Drk-99Drk-02Drk-07

0100200300400

Page 13: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Series resistance data, STC/dark I-V on LACSS

1988 A Dark increase ~ 1.2 to 2.0 Ω-cm2

Light increase ~ 0.8 to 1.4 Ω-cm2

1994 A #1 & #2 Dark increase ~ 2.1–2.8 to 4.5–6 Ω-cm2

Light increase ~ 1.4 to 2.0 Ω-cm2

1998 A Dark increase: 1.2 to 5 Ω-cm2

light increase: 1 to 2.8 Ω-cm2

1997 A (PERT) Dark increase (2002–06): 1 Ω-cm2

light increase (2002–06): ½ Ω-cm2

0.0

1.0

2.0

3.0

4.0

5.0

6.0

Jun-99 Jun-00 Jun-01 Jun-02 Jun-03 Jun-04 Jun-05 Jun-06 Jun-07 Jun-08

Rse

ries

(Ohm

-cm

2 )

1988 A Drk 1988 A Lit1994 A I Drk 1994 A I Lit1994 A II Drk 1994 A II Lit1997 A drk 1997 A Lit1998 A Drk 1998 A Lit2002 B Drk 2002 B Lit

(1997 A) substantial metastable drop in Rs of 3.5 or 1 Ω-cm2 for dark or light, while module lay indoors 1 year

Also reflected in performance (in & out) 2002 B

Dark 1.5 to 2.3 Ω-cm2

Light 0.6 to 1.4 Ω-cm2

2002 B (PERT) Dark nearly no change ~ 1.8 Ω-cm2

light nearly no change ~ 1.5 Ω-cm2

Rse increases impact type A more than type B because of higher Jsc for A (STC) ~30 mA/cm2 for A, ~24 mA/cm2 for B

Dark (filled), Light (open) symbols

Long-term exposure rack modules shown, with A & B from PERT occasionally tested on LACSS

Manually drawn trend lines shown as guide

Page 14: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Diode J0, A factors, STC/dark I-V on LACSS

A from dark or light dV/dJ–1/J data; J0 from dark Log(Jcor) –VcorA modules (over 8-years period) Quality factors changes between

negligible to 20% increases Dark J0 increases small, highest factor

of x2 B modules (over 5-year period) Quality factors show more substantial

gain, 25%-30% J0 changes by mult factor up to 40More detail picture show 2-diode type

behavior, primary weakeningJun-99 Jun-08Jun-00 Jun-02 Jun-04 Jun-06

10-7

10-6

10-5

10-8J 0

(A/c

m2 )

10-4 1988 A Drk 1994 A I Drk1994 A II Drk 1997 A drk1998 A Drk 2002 B Drk

ctor

3.0

3.5 1988 A Lit1994 A I Lit1994 A II Lit1997 A Lit1998 A Lit2002 B Lit

1988 A Drk1994 A I Drk1994 A II Drk1997 A drk1998 A Drk2002 B Drk

Dio

de Q

ualit

y Fa

c

1.5

2.0

2.5

Jun-99 Jun-08Jun-00 Jun-02 Jun-04 Jun-061.0

1.5

Page 15: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Sample PERT 1997 A Data: Across Irradiance Roc(Irr), FF(Irr) & Voc(Irr) from top to bottom

Segregated data by irradiance bins ±25 W/m2, Linear regression with Tmod, evaluated at 25°C; data partitioned into 3-month semesters 2002-08 Examine 3 irradiance ranges, each spanning ±75

W/m2 , at low (250 W/m2), mid (500 W/m2) , & high (1000 W/m2) intensities

Sample data for Fall 2002, Fall 2004 & Spring 2008 Voc vs. Irradiance data: slight drop with time, FF vs. Irradiance data

Peak in FF at 250 W/m2, followed by linear decline toward high irradiance typical of many modules consistent with compromise between series resistance loss vs. optical transparency

exhibit 5% relative decline for all irradiance above 250 W/m2, consistent with series resistance (Rse) increase

Roc vs. 1/ Isc data intercept gives Rse increase of about 0.6 ohms, or 50% relative

Irradiance (W/m2)

1 / Isc (A-1)

Fall '02Fall '04Spring '08

0 100 200 300 400 500 600 700 800 900 1000 1100

Roc

(Ohm

s)

0.0 0.5 1.0 1.5 2.0 2.5 3.00.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

Rse

Irr > 300 W/m2

Fall '02Fall '04Spring '08

19

20

21

22

23

24

25

26

Voc

(vol

ts)

56

57

5859

60

61

6263

64

65

FF (%

)

± 75W/m2

± 75W/m2

± 75W/m2

Page 16: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

PERT 1997 A Data: Power Parameters vs. time

Data in 3 irradiance bands, low to high irradiance, plotted vs. time Voc & Jsc normalized to cell level Performance (δEff /δt) loss rates1.3 %/yr to 1.5 %/yr all 3 bands

FF degradation rates dominate loss0.6 %/yr to 0.8 %/yrLower FF at high irradiance coupled with

higher FF at low irradiance consistent with series resistance as failure mode

Jsc decline next discernable loss mode0.4%/yr at 1000 W/m2, or 0.7%/yr lower

irradiance

1997 A

Jsc

(mA

/cm

2 )E

ffici

ency

(%)

Cel

l Voc

(mV

)FF

(%)

5

6

7

8

9

10

51015202530

565860

62

6466

400

450

500

550

1000 W500 W250 W

1000 W500 W250 W

1/02 1/03 1/04 1/05 1/06 1/07 1/08

Page 17: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Sample PERT 2002 B Data: Across Irradiance Roc(Irr), FF(Irr) & Voc(Irr) from top to bottom

Segregated data by irradiance bins ±25 W/m2, Linear regression with Tmod, evaluated at

25°C; data partitioned into 3-month semesters 2002-

08 Examine 3 irradiance ranges, each spanning

±75 W/m2 , at low (250 W/m2), mid (500 W/m2) , & high (1000 W/m2) intensities

Sample data for Fall 2002, Fall 2004 & Spring 2008 Voc vs. Irradiance data: small but discernable drop

vs. time lately FF vs. Irradiance data, between 2002 and 2008

Plateau behavior in FF from low to high increasing irradiance, not typically consistent with series resistance loss mode, but Gsh losses

10 % relative decline at 250 W/m2, 5 % relative decline at 500 W/m2, 3 % relative decline at 1000 W/m2,

Rse: Roc vs. 1/Isc data intercept No apparent significant increase

Irradiance (W/m2)

Voc

(vol

ts)

39

41

43

45

47

49

51

53

55

FF (%

)

42444648505254565860626466687072

0 100 200 300 400 500 600 700 800 900 1000 1100

Fall '02Fall '04Spring '08

1 / Isc (A-1)0.0 0.5 1.0 1.5 2.0 2.5 3.0

Irr > 300 W/m2

Roc

(Ohm

s)

0123456789

101112

Rse

Fall '02Fall '04Spring '08

± 75W/m2

± 75W/m2

± 75W/m2

Page 18: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

PERT 2002 B Data: Power Parameters vs. timeData in 3 irradiance bands, low to high

irradiance, plotted vs. time Voc & Jsc normalized to cell level Performance (δEff /δt) loss rates-2.3 %/yr low, -1.8 %/yr mid, -1.0 %/yr

high irradiance

FF degradation rates dominate performance loss rates-1.31 %/yr, -0.80 %/yr, -0.51 %/yr at low,

mid, high irradianceLow & mid irradiance losses appear larger

initially

Voc declines ~ -0.4%/yr Jsc declines -0.7%/yr at low & mid 7

8

9

10

11

Jsc

(mA

/cm

2 )E

ffici

ency

(%)

Cel

l Voc

(mV

)FF

(%)

1/02 1/03 1/04 1/05 1/06 1/07 1/08

60626466687072

1000 W500 W250 W

05

10152025

550

600

650

700

1000 W500 W250 W

2002 B

Page 19: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

PERT 1997 A & 2002 B: Rse, A Data vs. time Rseries extrapolated for Irr > 300 W/m2 for

each set Roc(Irr)-1/Isc(Irr) each semester, if regression includes lower Irr does not

alter results significantly except scatter A module Rseries degrades (increases) 0.4 to 0.5

ohms in over 6 years Point at Aug-2007 correlates with

metastable performance Diode quality factor degrades (increases)

at rate ~ 2.5 %/yr B module Rseries: statistically no change Diode quality factor degrades (increases)

at rate ~ 0.7 %/yr

R s

erie

s (O

hm)

Dio

de Q

ualit

y Fa

ctor

0.00.20.40.60.81.01.21.41.61.82.0

1.01.21.41.61.82.02.22.42.62.83.0

1997 A2002 B

1997 A2002 B

Jan-02 Jan-04 Jan-06 Jan-08

Page 20: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

(+ String) Sample HVST2 Data : Across Irradiance Roc(Irr), FF(Irr) & Voc(Irr) from top to bottom segregated data by irradiance bins ±25

W/m2, 3 irradiance ranges, at low, mid, & high intensities, regression to evaluate parameters at 25°C

data for Jun’05 thru Apr’08 color coded in rainbow-spectral-sequence: red earlier ‘05, blue latter ‘08

Voc vs. Irradiance data: slight but palpable drop vs. time

FF vs. Irradiance data exhibit 10% relative decline between Jun’05 and Apr’08

Rse: Roc vs. 1/Isc data intercept Obvious shift in Rse to higher values vs.

time by ~ 4-5 ohms

Stri

ng R

oc (O

hms)

0

10

20

30

40

50

60

1 / Isc (A-1)0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8

Irradiance (W/m2)

Stri

ng V

oc (V

)

220230240250260270280290

0 200 400 600 800 1000

FF (%

)

52

54

56

58

60

62

64

66

± 75W/m2

± 75W/m2

± 75W/m2

Irr > 300 W/m2

Oct-05Mar-06Nov-06Mar-07Nov-07Apr-08

Jun-05Jan-06Aug-06Jan-07Sep-07Feb-08

Oct-05Mar-06Nov-06Mar-07Nov-07Apr-08

Jun-05Jan-06Aug-06Jan-07Sep-07Feb-08

Page 21: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

HVST2 array Power Parameters vs. time: (– string)Data in 3 select irradiance bands shown, adjacent bands averaged, span ±75 W/m2

Time span: Apr. 2005 – Jul. 2008

Efficiency loss rates moderately high FF degradation rates leadVoc degradation also discernable initial ~ 284 V (6 V less than + string)

Some Isc loss rate at high irradianceNegative string summary loss rates

250 W/m2

(%/yr)500 W/m2

(%/yr)1000 W/m2

(%/yr)Eff -3.7 ±0.95 -3.4 ±0.68 -4.8 ±0.29FF -3.1 ±0.24 -3.1 ±0.22 -3.7 ±0.30

Voc -0.52 ±0.12 -0.36 ±0.07 -0.30 ±0.09Isc -0.24 ±0.76 0.15 ±0.66 -0.99 ±0.21

Negative String

1000 W

250 W500 W

1000 W

250 W500 W

Stri

ng Is

c (A

)S

tring

Voc

(V)

FF (%

)E

ffici

ency

(%)

0.61.01.41.82.22.6

5

6

7

8

9

10

250260

270280290

55

57

59

61

63

Apr-05 Apr-06 Apr-07 Apr-08

Page 22: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

HVST2 array Power Parameters vs. time: (+ string)Data in 3 select irradiance bands shown, adjacent bands averaged, span ±75 W/m2

Time span: Apr. 2005 – Jul. 2008

Efficiency loss rates moderately high, but discernable lower than for negative string

FF degradation rates lead, then VocMost loss rates smaller than for Voc loss

lower than negative at high irradiance Isc loss at high irradiance

Positive string summary loss rates250 W/m2

(%/yr)500 W/m2

(%/yr)1000 W/m2

(%/yr)Eff -3.3 ±1.15 -2.0 ±0.83 -3.3 ±0.34FF -2.2 ±0.31 -2.0 ±0.29 -2.0 ±0.30

Voc -0.45 ±0.12 -0.20 ±0.07 -0.21 ±0.07Isc -0.93 ±0.86 0.33 ±0.77 -1.13 ±0.29

Positive String

Stri

ng Is

c (A

)S

tring

Voc

(V)

FF (%

)E

ffici

ency

(%)

0.61.01.41.82.22.6

5

6

7

8

9

10

250260

270280290

55

57

59

61

63

Apr-05 Apr-06 Apr-07 Apr-08

1000 W

250 W500 W

1000 W

250 W500 W

Page 23: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

HVST2 ± strings: Rse, A Data vs. time Rseries 2005 to 2008 Both strings start out at nearly

identical values (~ 9 ohms), but increase 4-6 ohms with timeGrowth in negative string’s Rse

outpaces the positive string by 2 ohms in 3 years

intercept derived for Irr > 300 W/m2

but including lower intensities produces similar results with larger scatter

Diode Q factors degradation (growth) rates: -string: 12 %/yr +string 7.5 %/yr

Neg StringPos String

Neg StringPos String

Stri

ng s

erie

s re

sist

ance

(Ohm

)A

vera

ge d

iode

qua

lity

fact

or p

er c

ell

02468

1012141618

1.0

1.5

2.0

2.5

3.0

3.5

Apr-05 Apr-06 Apr-07 Apr-08

Page 24: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Conclusions: Performance Loss Rates @ STC Long-term exposure rack modules: Type A, SPIRE (1 of 1988, 2 each 1990, 1992, 1994, 1998)Predominantly FF losses via Rse increases, followed by Voc lossIsc losses likely not significant

Type 2002 B (2 modules SPIRE & LACSS, includes one on PERT)Loss rate in FF counter-balanced by increase rate in Voc

Module Type ∆Voc/Voc (%/yr)

∆Isc/Isc (%/yr)

∆FF/FF (%/yr)

∆ Eff / Eff (%/yr) TIMELINE

1988 A -0.25% 0.36% -1.09% -0.90% Nov-90 –Mar-08

1990 A -0.02% 0.01% -0.24% -0.26% Oct-91–Mar-08

1992 A -0.05% 0.19% -0.55% -0.43% Aug-92–Mar-08

1994 A -0.08% -0.11% -0.84% -1.01% Mar-95–Mar-08

1998 A -0.24% -0.15% -1.89% -2.19% Jan-99–Mar-08

2002 B 0.57% -0.16% -0.83% -0.40% Aug-02–Mar-08

Page 25: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Conclusions: Performance Loss Rates PERT Average loss rate 1997 A: -1.4 %/yr, FF declines from Rse increase dominate performance loss Jsc decline next more important sizeable loss

Average loss rate 2002 B: -1.7 %/yr FF declines dominate performance loss, likely from shunt increase, Jsc decline next important sizeable loss, but Voc loss larger at high irradiance

Average over 3 irradiance windows (250 W/m2, 500 W/m2, 1000 W/m2)

Module 250 W/m2 (%/yr)

500 W/m2 (%/yr)

1000 W/m2 (%/yr)

Eff -1.3 ± 0.08 -1.5 ±0.04 -1.3 ±0.03 FF -0.60 ±0.13 -0.75 ±0.13 -0.84 ±0.20

Voc -0.07 ±0.00 -0.05 ±0.00 -0.13 ±0.00 Jsc

1997 A

-0.68 ±0.06 -0.71 ±0.06 -0.37 ±0.04

Module 250 W/m2 (%/yr)

500 W/m2 (%/yr)

1000 W/m2 (%/yr)

Eff -2.3 ±0.09 -1.8 ±0.04 -1.0 ±0.02 FF -1.31 ±0.29 -0.80 ±0.15 -0.51 ±0.09

Voc -0.45 ±0.00 -0.35 ±0.00 -0.38 ±0.00 Jsc

2002 B

-0.74 ±0.04 -0.72 ±0.04 -0.13 ±0.05

Page 26: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan

Conclusions: Performance Loss Rates HVST2 Decline rates averaged Negative string degradation at -4.0 %/yr

Decline rates averaged Positive string degradation at -2.9 %/yr

High-voltage stress may lead to higher degradation in these A (2003) modules Higher loss may also be result of manufacturer process, probably both

FF decline & Rseries increases dominate performance loss/failure mode: 11%/yr and 20%/yr, for the positive and negative strings, respectively

Degradation rates consistent with earlier analysis done via PTC regression method Average over 3 irradiance windows (250 W/m2, 500 W/m2, 1000 W/m2)

250 W/m2

(%/yr)500 W/m2

(%/yr)1000 W/m2

(%/yr)Eff -3.3 ±1.15 -2.0 ±0.83 -3.3 ±0.34FF -2.2 ±0.31 -2.0 ±0.29 -2.0 ±0.30

Voc -0.45 ±0.12 -0.20 ±0.07 -0.21 ±0.07Isc -0.93 ±0.86 0.33 ±0.77 -1.13 ±0.29

250 W/m2

(%/yr)500 W/m2

(%/yr)1000 W/m2

(%/yr)Eff -3.7 ±0.95 -3.4 ±0.68 -4.8 ±0.29FF -3.1 ±0.24 -3.1 ±0.22 -3.7 ±0.30

Voc -0.52 ±0.12 -0.36 ±0.07 -0.30 ±0.09Isc -0.24 ±0.76 0.15 ±0.66 -0.99 ±0.21

Page 27: Long-Term Performance Data and Analysis of CIS/CIGS ...Long-Term Performance Data and Analysis of CIS/CIGS Modules Deployed Outdoors J. A. del Cueto, B. Kroposki, S. Rummel, Allan