log homes in rescheck - energy codesrescheck report matches the materials at the construction site....
TRANSCRIPT
![Page 1: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/1.jpg)
1
Log Homes in REScheckCalculations and Demonstration
Log Homes in REScheckLog Homes in REScheckCalculations and DemonstrationCalculations and Demonstration
![Page 2: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/2.jpg)
2
Calculation BackgroundCalculation BackgroundCalculation Background
REScheck versions prior to 3.7.1 calculated log wall u-values based on nominal width and assumed average weights.
Provided a calculation based only on the nominal width.Assumed 12% moisture content 0.39 Btu/lb-F. (ASHRAE 1985)Average weight on the basis of wood density (12% moisture) for west coast woods and cedar. (ASHRAE 1985)Mass wall credit for heat capacity greater than 6 Btu/ft2-F, or 7”+ log walls.
![Page 3: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/3.jpg)
3
Thermal Flow CalculationThermal Flow CalculationThermal Flow Calculation
)____(1
filmairoutsidefilmairinsidewidthvalueRU
++•−=
Conditioned Space
Heat Transfer (loss)
Inside Air Film, 0.68
R-value calculated based on species
/widthOutside Air Film, 0.17
![Page 4: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/4.jpg)
4
Cavity and Continuous InsulationCavity and Continuous InsulationCavity and Continuous Insulation
Cavity InsulationInsulation installed between structural members such as wood studs, metal framing, and Z-clips.
Continuous InsulationInsulation that runs continuously over structural members and is free of significant thermal bridging; such as rigid foam insulation above the ceiling deck. It is installed on the interior, exterior, or is integral to any opaque surface of the building envelope.
![Page 5: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/5.jpg)
5
Wood Species and Specific GravityWood Species and Specific GravityWood Species and Specific Gravity
0.42YCYellow Cedar (YC)
0.39RP-NRed-Canadian Pine (RP-N)
0.39PPPonderosa Pine (PP)
0.39LPPLodgepole Pine (LPP)
0.39HFHem-Fir (HF)
0.38WSWestern Softwoods (WS)
0.38ESEastern Spruce (ES)
0.38ESWEastern Softwoods (ESW)
0.38ESPFE. Spruce-Pine-Fir (ESPF)
0.37WSPFW. Spruce-Pine-Fir (WSPF)
0.37WFWhite Fir (WF)
0.35WWPWestern White Pine (WWP)
0.35EWPEastern White Pine (EWP)
0.35ICIncense Cedar (IC)
0.34SUPSugar Pine (SUP)
0.31WRCWestern Red Cedar (WRC)
0.31WRC-NWestern Red Canadian Cedar
(WRC-N)
0.31RCRed Cedar (RC)
0.3WCWhite Cedar (WC)
(Gu)
Specific GravitySpecies LabelWood Species Group
0.62WOWhite Oak (WO)
0.57RORed Oak (RO)
0.54SHPSlash Pine (SHP)
0.54LLPLongleaf Pine (LLP)
0.49TAMTamarack (TAM)
0.48SPSouthern Pine (SP)
0.48MSPMixed Southern Pine (MSP)
0.47SLPShortleaf Pine (SLP)
0.47LBPLoblolly Pine (LBP)
0.45DFLDouglas Fir-Larch (DFL)
0.43CYPBaldcypress (CYP)
0.42RPRed Pine (RP)
(Gu)
Specific GravitySpecies LabelWood Species Group
![Page 6: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/6.jpg)
6
Mass Wall CalculationMass Wall CalculationMass Wall Calculation
Photo by Pikaluk/http://www.flickr.com/
Mass walls simply have different heat storage capabilities.For a wall to receive the Mass Wall credit in the IECC, the wall must have a heat capacity (HC) of 6 Btu/ft2 F. Density Calculation (lb/ft3)
D = 62.4 · [G / (1+ (0.009·G·MCs ))] · (1+ MCs/100)
Heat Capacity Calculation HC = D · c · (Nd/12)c is specific heat 0.39 lb-F for all species Nd is the Nominal Width of the log wall in inches
![Page 7: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/7.jpg)
7
R-Value CalculationRR--Value CalculationValue Calculation
Moisture correction G = Gu / (1- (0.265 ·a·Gu ))Where Gu is the specific gravity as noted and a is calculated for each species
Thermal Conductivity (Btu-in/(h-ft2-F)k = G ( B + C(MCs) ) + A A = 0.129 (Specific gravity greater than 0.30)B = 1.34 (Design temperature at 75 F)C = 0.028 (Moisture content less than 25%) MCs = 12% for all other climates
Photo by Carmdir/http://www.flickr.com/
![Page 8: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/8.jpg)
8
Mass Wall OverviewMass Wall OverviewMass Wall Overview
species 5 inch 6 inch 7 inch 8 inch 9 inch 10 inch 12 inch 14 inch 16 inchWCRCWRC-NWRCSUPICEWPWWPWFWSPFESPFESWESWSHFLPPPPRP-NYCRPCYPDFLLBPSLPMSPSPTAMLLPSHPROWO
![Page 9: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/9.jpg)
9
2003 IECC Mass Wall Table2003 IECC Mass Wall Table2003 IECC Mass Wall Table
![Page 10: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/10.jpg)
10
Calculation FutureCalculation FutureCalculation Future
Moisture content may vary by location.
MCs = 10% for Dry climateMCs = 13% for Moist climatesMCs = 15% for Marine climatesMCs = 14% for Warm-Humid climatesMCs = 12% for all other climates
![Page 11: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/11.jpg)
11
Calculation ChangesCalculation ChangesCalculation Changes
Code officials should now check that the letter code specified in the REScheck report matches the materials at the construction site. Check that the log width specified in the REScheck report matches the material at the construction site.
![Page 12: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/12.jpg)
12
TroubleshootingTroubleshootingTroubleshooting
Consider lower glazing areas.This will have an impact on compliance with codes prior to the 2004 IECC.
Consider more efficient windows if you are not already using them.
Many windows have become less expensive in recent years. Look for low u-values on the order of 0.40 or less.
Add insulation to the log wall. As little as R-4 may mean the difference in compliance in some areas and will improve the comfort of the occupants.
Seal the home carefully. Air leakage is a major source of heat loss in many homes.
![Page 14: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/14.jpg)
14
Residential Compliance ToolsResidential Compliance ToolsResidential Compliance Tools
Desktop Software Tools
Web-Based Tools
Printed Materials
Compliance Guides
Prescriptive Tables
![Page 15: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/15.jpg)
![Page 16: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/16.jpg)
16
Updated Version 3.7 Release 1b Time clock – January 23, 2006 implementedBaseline for equipment trade-offs is now
SEER 13HSPF 7.7
No penalty for pre-2006 efficiencies envelope trade-offs only
Update will affect all code compliance options in RESchecknational codes state-specific codes
What’s New with MechanicalWhatWhat’’s New with Mechanicals New with Mechanical
![Page 17: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/17.jpg)
17
![Page 18: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/18.jpg)
18
![Page 19: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/19.jpg)
19
![Page 20: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/20.jpg)
20
Log Home Case StudiesLog Home Case StudiesLog Home Case Studies
![Page 21: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/21.jpg)
21
SimpleSimpleSimple
![Page 22: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/22.jpg)
22
c
Complex
Courtesy of Kuhns Bros. Log Homes Inc.
![Page 23: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/23.jpg)
23Courtesy of Kuhns Bros. Log Homes Inc.
![Page 24: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/24.jpg)
24
MasterBedroom
Deck
Great Room*Cathedral Area*
DiningRoom
Garage
Porch
Kitchen
Entry
Courtesy of Kuhns Bros. Log Homes Inc.
![Page 25: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/25.jpg)
25
Open to Below
Bedroom #2 Bedroom #3
Loft*Cathedral Area*
Walk-InCloset
Walk-InCloset
Walk-InCloset
Walk-InCloset
Bath
![Page 26: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/26.jpg)
26
Setting the Standard NewsletterSetting the Standard NewsletterSetting the Standard Newsletter
Register on-line to receive the latest up-to-date information on energy code related issues
Newsletterhttp://www.energycodes.gov/news/
![Page 27: Log Homes in REScheck - Energy CodesREScheck report matches the materials at the construction site. ¾Check that the log width specified in the REScheck report matches the material](https://reader034.vdocuments.us/reader034/viewer/2022042605/5f434aa89a9e742cb317769e/html5/thumbnails/27.jpg)
27
Questions/CommentsQuestions/CommentsQuestions/Comments
Help Desk – on-line electronic formhttp://www.energycodes.gov/support/helpdesk.php
U.S. Department of Energy’s Building Energy Codes Program
PNNL-SA-48506