local area network management,design and security

37
Local Area Network Management,Design and Security • Hårdvara i LAN – Kap.3 i kursboken • Jag har kastat in delar i kapitlet.

Upload: decker

Post on 25-Feb-2016

24 views

Category:

Documents


0 download

DESCRIPTION

Local Area Network Management,Design and Security. Hårdvara i LAN Kap.3 i kursboken Jag har kastat in delar i kapitlet. Servrar. Filhantering (fig 3.2) Diskserver Filserver Applikationsservrar Klient/server-teknik Databas Ekonomisystem Web/FTP/m.fl. ”Terminal”-teknik - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Local Area Network Management,Design and Security

Local Area NetworkManagement,Design and

Security

• Hårdvara i LAN– Kap.3 i kursboken

• Jag har kastat in delar i kapitlet.

Page 2: Local Area Network Management,Design and Security

Servrar

Filhantering (fig 3.2)• Diskserver• Filserver• Applikationsservrar

– Klient/server-teknik• Databas• Ekonomisystem• Web/FTP/m.fl.

– ”Terminal”-teknik• MS Terminal server/Citrix• m.fl.

Page 3: Local Area Network Management,Design and Security

The disk server lets users share the disk.

Programs and data can be shared on the file server

User 1 User 2 User 3

User 9

U. 1 User 2 Word proc..

Spreadsheets

Other progsUser area Data area

Fig. 3.2 s. 114

Page 4: Local Area Network Management,Design and Security

Högprestanda-anslutning SB

• SCSI (SCUZZY).• Serial SCSI IEEE1394 (FireWire, i.Link)• IP storage/iSCSI• Fibre Channel• Serial ATA

Page 5: Local Area Network Management,Design and Security

Disk

CD-rom

Terminator

Terminator

Disk

CD-rom

Terminator

Terminator

PrinterScanner

Internal devices

Externaldevices

Internaldevices

Fig. 3.4 SCSI-terminering

Page 6: Local Area Network Management,Design and Security

SCSI (scuzzy)Small Computer System

Interface

• SCSI-1 5MHz 8bitar 40Mbps 1 enhet.• SCSI-2 standard SCSI (Narrow).

– Narrow 5MHz 8bitar 40Mbps 7 enheter– Fast 10MHz 8bitar 80Mbps 7 enheter.– Wide 5MHz 16bitar 80Mbps 15 enheter.– Fast Wide 10MHz 16bitar 160Mbps 15 enh.

Page 7: Local Area Network Management,Design and Security

SCSI (scuzzy) SB

• SCSI-3.– Ultra SCSI 20MHz 8 bitar 160Mbps (20) 7/3…– Wide Ultra SCSI 20 16 320Mbps (40) 15– Ultra2 SCSI 40 8 320Mbps (40MByte/s) 7– Wide Ultra2 SCSI 40 16 640 (80MByte/s) 15– Ultra3 SCSI 80 8 640Mbps 7 (80MByte/s) 7– Wide Ultra3(Ultra160) 80 16 1280Mbps (160MB/s) 15– Ultra320 160 16 2560Mbps (320MByte/s)

15

Page 8: Local Area Network Management,Design and Security

SCSI (scuzzy) SB

• Singel ended (SE) 1 tråd/signal (1,5-3m)• Differential 2 trådar /signal (motsatt

spänning) (25m)• Low-voltage differential (LVD)

lägre spänning (12m)• SCA Single Connector Attachment

Page 9: Local Area Network Management,Design and Security

SCSI (scuzzy)

• Kontakter Table 3.3 s.119– + VHDCI

• SCSI ID– Kontroller ID# 7 (Högst prioritet)– Bootdisk ID# 0

• Terminering Fig. 3.4 s.120• Table 3.4 s.121 obs id# 7 & Diff./LVD

Page 10: Local Area Network Management,Design and Security

Serial SCSI IEEE1394 (FireWire, i.Link) SB

• IEEE1394 FireWire100-400 Mbps 12,5-50 MBps

• IEEE1394B FireWire800/FireWire1600800-1600 Mbps 100-200 MBpsSkärmad koppar 4,5m,CAT-5 & Fiber 100m

• [45W]

Page 11: Local Area Network Management,Design and Security

IP storage/iSCSI SB

• IP Storageis a technology that encompasses block storage transfer over an IP network.

• iSCSI is a protocol standard for encapsulating SCSI in TCP/IP for transfer over an IP network

• TCP Offload Technology TCP Offload Engine (TOE)

Page 12: Local Area Network Management,Design and Security

Fibre Channel SB

• Seriellt kommunikationsprotokoll används:– Punkt till punkt– Ringnät (FC-AL) max 126 enheter

Fibre Channel Arbitrated Loop– Växlat nät (FC fabric) Fibre Channel Fabric 224

adresser (~16 miljoner enheter)

Olika fabrikat sällan helt kompatibla

Page 13: Local Area Network Management,Design and Security

Fibre Channel SB

• Koppar-kabel (500m)- eller Fiber-kabel (~10 km)

• Dubblerad kabel för säkerhetens skull.• Felrättande kod på byte och paketnivå• Hastigheter: 100MByte/s -> 400MByte/s

På gång (1,6 GByte/s = 12,8 Gbit/s)• Enheter kan anslutas under drift (Hot-plug)• LAN Free backup

Page 14: Local Area Network Management,Design and Security

Fibre Channel Class Of Service SB

• FC Class-1: Dedicated connection, full bandwidth, and confirmed delivery

• FC Class-2: Confirmed delivery• FC Class-3: "Data Gram" delivery NOT

confirmed• FC Class-4: Virtual Connection, fractional

bandwidth, confirmed delivery

Page 15: Local Area Network Management,Design and Security

Serial ATA SB

• 150 MByte/sec (SATA II 300MByte/s)Serial ATA is a "serial" architecture as opposed to today's "parallel" ATA internal disc drive bus.Serial ATA wraps many bits of data into a packet and then at a higher speed (up to 50% higher) than parallel, transfers the packet of data down the wire to or from the host.(Point-to-point)

With ”parallel” ATA Cyclic Redundancy Checking (CRC) is performed on the data being transmitted back and forth but not on the commands.

Serial ATA integrates CRC on the command and data packet level for enhanced bus reliability. Cyclic redundancy code detects all single and double-bit errors and ensures detection of 99.998% of all possible errors.

A Serial ATA drive can transfer data at 150MB/sec on the bus to the host system with extremely reliable accuracy and the Serial ATA interface will continue to allow scalability for a very long time.

http://www.serialata.org/

Page 16: Local Area Network Management,Design and Security

Hårdvara i en server

• Datalagring• Bussar & In/Ut-enheter (I/O)• Primär-minne• Moderkort/Chipset• CPU/Cache• Låda med power-supply och UPS• Backupenheter• Network Interface Card (NIC)

Page 17: Local Area Network Management,Design and Security

Datalagring

• Floppydisk (FDD) (Diskett)• Diverse skivor (ZIP-Drive. MMO m.fl)• CD/DVD CD/RW• CD-växlare

Stora system kostar ofta 500-1000:-/cd-plats.Flera läsare/brännare kan ofta installeras i växlaren och dessa kan då användas parallellt.

• Hårddiskar (HDD)• ”Tapestorage”

Page 18: Local Area Network Management,Design and Security

Hårddiskar (HDD) SB

• IDE 2 st enheterEIDE 2+2 st enheter (vanligast)

• SATA 1st enhet/anslutning• SCSI 1 & 2 7st enheter

SCSI 2 & 3 (Wide) 15st enheter------------------------------------------------

• JBOD Just a Bunch Of Disks• RAID• NAS/SAN

Page 19: Local Area Network Management,Design and Security

Bussar

• ISA• EISA• MCA• Local bus• VESA local bus• PCI local bus• AGP(1,2,4,8)

(Interna, på moderkortet)

Page 20: Local Area Network Management,Design and Security

Bild med jämförelse av ”bus”-prestanda

• Table 3.5 s.128+ AGPx8

Page 21: Local Area Network Management,Design and Security

In/Ut-enheter (I/O) In/Ut-enheter (I/O) SBSB

1. Serie-portar2. Parallell-portar3. USB (Universal Serial Bus)4. IEEE1394/1394B (FireWire, i.Link)5. IDE/EIDE (Integrated drive electronics)6. SATA (Serial ATA)7. SCSI (Scuzzy) (Small computer system interface)8. SSA (Serial storage architecture)9. Fibre Channel10. IP-storage/iSCSI

Page 22: Local Area Network Management,Design and Security

Primär-minne

• MinneGrundrek. 512-1024 Mbyte i server

• Läs om minnen s.128-132• SDRAM• DDR-SDRAM (Dubbel fart)• Direct Rambus DRAM (DRDRAM)

Page 23: Local Area Network Management,Design and Security

Moderkort/Chipset

• AT/ Baby AT (! För gammalt)• ATX (Vanligaste kortet)• LPX (PCI-kort på eget ”kort”)• NLX (PII/PIII-processor, USB ingår)• WTX (Lågpris-kort)• EATX (Ej standard max 13” x 12”

”Rackmonteringskortet” 1U)• Chipset ! (s.138-139)• Flerprocessorkort

Nytt

Page 24: Local Area Network Management,Design and Security

CPU/Cache SBSB

• CPU2 st endast 50% ökning av prestanda, men en hängd CPU tillåter ändå access till datorn om den andra svarar.

• Cache L1, L2 (L3 i minnet)

Page 25: Local Area Network Management,Design and Security

Låda med power supply• Krav på låda för server:

– Bra med platser för enheter– Luftig (Bra med utrymme och bra fläktar)– Power supply ska orka driva allt.

• Figure 3.13 & Table 3.8 s.140 + Rackmonterat 19”-rack

• Redundant power supplyDubblerad strömförsörjning inne i dator eller annan utrustning, var och en klarar av att driva hela utrustningen själv.

Page 26: Local Area Network Management,Design and Security

UPS

UPS (Uninterruptible Power Supply)– Batteri-drift– Störskydd– Signalkabel fig.6.15 s.244– Driftstid batterier?– Skydd för NIC?– Övervakningsbar? (SNMP)

Page 27: Local Area Network Management,Design and Security

UPS

COM1:

Power net

Fig 6.15 s.244

Page 28: Local Area Network Management,Design and Security

Backup-enheter S.141-143

• Disketter• Andra skivor

– Zipdrive/LS-120 mfl– CD/RW– DVD/RW

• Minnesmoduler (extremt snabbt )• Flyttbara hård-diskar• Backup-station

Page 29: Local Area Network Management,Design and Security

Backup-station SB

• Automatisk Backup:– Autochanger, Autoloader, Library

• Backup-tape:– QIC -> 6Mbyte/minut 1-5Gbyte– 4mmDAT 2.4 Mbyte/sec 40GB compressed– D8 (8mm) 14GB ?– DLT III- IV 1,5-6Mbyte/sec 20-80GB compressed– Super DLT 12Mbyte/sec 100- GB compressed (Quantum.)

– AIT Advanced Intelligent Tape (SONY)

– Ultrium (Ultrium Linear Tape Open (LTO))IBM, HP and Seagate’s nya bandtyp Generation 1 tape max 100Gbyte

Page 30: Local Area Network Management,Design and Security

AIT-1 SB

• AIT-1 format, introduced in 1996,capacity 25GB (65GB compressed*)An extended length tape for the AIT-1 drive was introduced to offer additional capacity of 35GB (91GB compressed*).3 (7,8)Mbyte/s data transfer rate (compressed*).

*2,6:1 komprimering

Page 31: Local Area Network Management,Design and Security

AIT-2 & 3 SB

• AIT-2 capacity 50GB (130GB) data transfer rate 6 (15,6)MB/s

• AIT-3capacity 100GB (260GB)data transfer rate 12 (31,2) MB/s.

(compressed)

Page 32: Local Area Network Management,Design and Security

Mer AIT Mer AIT SBSB

• SAIT-1capacity 500GB and a data transfer rate of up to 30MB/s.

• AIT-4 is now in development planning for 2004. In keeping with the original plan of doubling capacity and transfer rate, this format would offer 200 (520)GB of native capacity, with a data transfer rate of 24 (62,4)MB/s

Page 33: Local Area Network Management,Design and Security

Ultrium Ultrium SBSB

• Ultrium provides for 4 different cartridge capacities (20, 60, 100, and 200 GB--assumes 2:1 compression) and 8-channel head geometries in the first generation that provides for data transfer rates of 20-40 MB/ second (2:1 compression). The multiple-capacity cartridges allow the technology to be matched to capacity, performance, and cost requirements of the application.Generation 1 Generation 2 Generation 3 Generation 4Capacity(2:1 comp)200 GB 400 GB 800 GB 1.6 TBTransfer Rate MB/sec 2:1 comp) 20-40 40-80 80-160 160-320

• Instant Access to Usage Data—via LTO CM (cartridge memory), an embedded electronics and interface module that can store and retrieve a cartridge's historical usage and other information.

Page 34: Local Area Network Management,Design and Security

Network Interface Card (NIC)Network Interface Card (NIC)

• Använd speciella NIC i server eftersom dessa har stöd för snabbare nätaccess, oftast i form av större buffrar.

• Stöd för automatisk växling (hot-spare) till reserv NIC kan också finnas.

• Läs mer om NIC & kablar i boken s.143-149 & 151-158

Page 35: Local Area Network Management,Design and Security

Klientdator (Workstation)Klientdator (Workstation)

• Klientdator – PC med NIC !• Tunna klienter (Disk-lösa)

– BootPROM på NIC – OS på server– PXE på NIC – OS på server

• MS Terminalservices

Page 36: Local Area Network Management,Design and Security

Skrivare Skrivare SBSB

• Skrivare(Printer)Till dom flesta laserskrivare finns nätverkskort som tillbehör.

Andra typer av skrivare kan via speciell extern nätverks-utrustning (print-server) ansluta standard parallell-port.

Page 37: Local Area Network Management,Design and Security

Övrigt Övrigt SBSB

• Hot-swapEnheten kan bytas under drift

• Hot-spareEnheten är monterad i förväg, normalt sker växling till ny enhet automatiskt

• Hot-plugEnhet kan kopplas in under drift jmf. USB, Ethernet hub/switch, SAN mfl.