STANDARD-TECH Report No.: GZE1706064-B-R Laboratory: Standard-Tech Co. Ltd Testing Center NVLAP CODE: 201011-0 Report Format Number STD/QR4909-A/2 AddressStandard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com 1 / 17 LM-79-08 Test Report For Builders Pack (Brand Name: Builders Pack) ShenFuBao Industry Park,Bonded area,Futian District,Shenzhen,China Architectural Flood and Spot Luminaires Model name(s): 57-50W-XXK-FL-XT05 Representative (Tested) Model: 57-50W-40K-FL-XT05 57-50W-57K-FL-XT05 Model Different: All construction and rating are the same, except CCT s Test & Report By: Review By: Bill Luo Engineer: Bill Luo Manager: Tommy Liang Date: Jun.19,2017 Update: Jul.24,2017 Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.

Upload: others

Post on 26-Jun-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

1 / 17

LM-79-08 Test Report

For

Builders Pack(Brand Name: Builders Pack)

ShenFuBao Industry Park,Bonded area,Futian District,Shenzhen,China

Architectural Flood and Spot Luminaires

Model name(s): 57-50W-XXK-FL-XT05

Representative (Tested) Model: 57-50W-40K-FL-XT0557-50W-57K-FL-XT05

Model Different: All construction and rating are the same, except CCT

s

Test & Report By: Review By:

Bill Luo Engineer: Bill Luo Manager: Tommy Liang

Date: Jun.19,2017

Update: Jul.24,2017

Note: This report does not imply product certification, approval, or endorsement by NVLAP, NIST, or

any agency of the Federal Government.

Page 2: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

2 / 17

Report No.

Revision

Revised Item:

Model Number

Revised

Reason Issue date

GZE1706064-B Client Requirement, in

order to be consistent

with safety model

number.

Jun.19,2017

GZE1706064-B-R Jul.24,2017

Page 3: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

3 / 17

1.1 Product Information:

Organization Name Builders PackBrand Name Builders PackModel Number 57-50W-XXK-FL-XT05SKU (if available) N/A

Type of Luminaire

(for integral lamps, list base type and lamp type) Architectural Flood and Spot Luminaires

Rated Voltage / Frequency 100-277Vac, 60Hz

Nominal Power 50W

Rated Initial Lamp Lumen --

Declared CCT 4000K,5000K,5700K

LED Manufacturer ShenZhen JuFei Optoelectronics Co., Ltd.

LED Model 2835 9V 1W White SMD LED

Sample Number GZE1706064-B1(4000K), B2(5700K)

Luminaire Aperture (for downlights) -- in.

Luminaire Length -- mm

Luminaires Width -- mm

Number of Units (modular products) N/A s

Photo

Page 4: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

4 / 17

1.2 Test Specifications:

Date of Receipt Jun.14,2017

Date of Test Jun.16,2017

Test item

1. Total Luminous Flux

2. Luminous Distribution Intensity

3. Luminous Efficacy

4. Correlated Color Temperature

5. Color Rendering Index

6. Chromaticity Coordinate

7. Electrical Parameters

Reference Standard

1. IES LM-79-2008 Electrical and Photometric Measurements of

Solid-State Lighting Products

2. ANSI C78.377-2008 Specifications for the Chromaticity of Solid

State Lighting Products

3. CIE 13.3-1995 Method of Measuring and Specifying Colour

Rendering Properties of Light Sources

4. CIE 15-2004 Technical Report Colorimetry

5. IESNA LM-16-93 Practical Guide to Colorimetry of Light Source

6. IESNA TM-16-05 Technical Memorandum on Light Emitting

Diode (LED) Sources and Systems

Reference Work Instruction QD25

1.3 Test Methods

1) Photometric and Light Distribution Measurement – Goniophotometer Method:

Photometric parameters were measured using the goniophotometer and software. The ambient

temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1 m from the

sample and at the same height as the sample. The sample was operated at 120 or rated Volts AC, 60Hz.

It was stabilized before measurement was made. Luminous flux, luminaire efficacy, zonal lumen were

calculated from the software taken at 1° vertical intervals and 22.5° horizontal intervals.

2) Chromaticity Measurement – Sphere-Spectroradiometer Method:

Chromaticity parameters were measured using an integrating sphere, a spectroradiometer and software.

The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C. The sample

measurements were made using a spectroradiometer connected by a fiber optic cable and detector

through the detector port of the integrating sphere. The sample was operated at 120 or rated Volts AC,

60Hz. It was stabilized before measurement was made. Chromaticity coordinates, correlated color

temperature and color rendering index were calculated from the spectral power distribution taken at 5

nm intervals over the range of 380 to 780 nm.

3) Electrical Measurements:

Electrical parameters were measured using power meters incorporated in goniophotometer or

sphere-spectroradiometer system. The ambient temperature surrounding the sample was maintained at

25º C ± 1º C. The sample was operated at 120 or rated Volts AC, 60Hz. It was stabilized before

measurement was made. Voltage, frequency, current, power, power factor and total harmonic distortion

were measured by and read from the power meter.

Page 5: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

5 / 17

2.1 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

Test date 2017-06-16 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number 57-50W-40K-FL-XT05

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE170606

4-B1

120.0 60 0.3884 46.30 0.9933 8.68

277.0 60 0.1790 45.56 0.9189 15.54

DLC Pass Criteria >= 0.9(-3%) <= 20(+5)

Chromaticity Measurement - Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 81 R9 9

Frequency (Hz) 60 R2 88 R10 71

CCT (K) 4053 R3 93 R11 79

Duv -0.0004 R4 81 R12 59

Chromaticity (x, y) x=0.3779 y=0.3744 R5 80 R13 83

Chromaticity (u’, v’) u'=0.2244 v'=0.5002 R6 83 R14 96

Color Rendering Index (CRI) 82.2 R7 86 R15 75

R9 9 R8 65 -- --

Photometric Measurement – Goniophotometer Method:

Parameter Result DLC V4.0 Pass Criteria

Test Voltage (V) 120.0 277.0 --

Frequency (Hz) 60 60

Total Luminous (lm) 4626.3 4514.9 5000-10000(-10%)

Luminous Efficacy (lm/W) 99.92 99.10 Standard: >=

95(-3%)

Premium: >=

115(-3%) Most Worst Luminous/Highest Watts 97.51

Zonal lumens in the 0-90° zone (%) 99.9 -- >= 85%(-3%)

Beam Angle (°) 105.9 -- --

Center Beam Candle Power (cd) 1765 -- --

Page 6: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

6 / 17

Zonal Lumen Tabulation

Zonal Lumen Summary

Zone Lumens % Luminaire

0-30 1,501.7 32.5%

0-40 2,520.9 54.5%

0-60 4,287.6 92.7%

60-90 333.2 7.2%

70-100 41.7 0.9%

90-120 1.3 0%

0-90 4,620.8 99.9%

90-180 4.8 0.1%

0-180 4,625.6 100%

Lumens Per Zone

Zone Lumens %Total Zone Lumens %Total

0-10 169.2 3.7% 90-100 0.4 0%

10-20 508.8 11.0% 100-110 0.4 0%

20-30 823.7 17.8% 110-120 0.5 0%

30-40 1,019.2 22.0% 120-130 0.7 0%

40-50 1,007.1 21.8% 130-140 0.8 0%

50-60 759.6 16.4% 140-150 0.8 0%

60-70 291.9 6.3% 150-160 0.7 0%

70-80 36.3 0.8% 160-170 0.4 0%

80-90 4.9 0.1% 170-180 0.2 0%

Spectral Power Distribution & Chromaticity Diagram

Page 7: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

7 / 17

Photometric Data

Page 8: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

8 / 17

Candela Table - Type C

0 22.5 45 67.5 90 112.5 135 157.5 180 202.5 225 247.5 270 292.5 315 337.5 360

0 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765 1765

1 1767 1771 1772 1774 1779 1745 1755 1759 1769 1773 1774 1780 1782 1746 1750 1762 1767

2 1769 1769 1769 1772 1780 1746 1757 1762 1770 1776 1773 1781 1784 1748 1754 1761 1769

3 1770 1771 1770 1772 1780 1748 1757 1761 1770 1776 1776 1787 1786 1749 1755 1760 1770

4 1768 1773 1773 1776 1783 1750 1752 1760 1771 1776 1782 1792 1788 1748 1753 1759 1768

5 1765 1769 1773 1781 1786 1751 1753 1760 1770 1777 1784 1792 1789 1748 1757 1757 1765

6 1765 1767 1771 1783 1789 1753 1754 1758 1768 1777 1786 1797 1796 1752 1759 1755 1765

7 1766 1766 1772 1785 1791 1753 1753 1756 1766 1776 1792 1801 1801 1758 1762 1755 1766

8 1766 1767 1773 1791 1794 1756 1755 1753 1761 1776 1792 1807 1809 1766 1766 1756 1766

9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761

10 1757 1765 1780 1798 1806 1763 1758 1750 1763 1775 1792 1822 1821 1779 1772 1755 1757

11 1751 1760 1786 1803 1814 1766 1758 1752 1763 1775 1798 1829 1830 1785 1777 1750 1751

12 1750 1757 1787 1811 1823 1771 1759 1755 1761 1779 1808 1835 1835 1790 1782 1750 1750

13 1749 1756 1789 1820 1833 1780 1760 1754 1760 1778 1813 1840 1843 1800 1781 1751 1749

14 1750 1757 1789 1824 1839 1786 1763 1749 1758 1776 1818 1847 1851 1807 1781 1749 1750

15 1749 1758 1788 1832 1845 1792 1766 1747 1753 1775 1823 1852 1862 1818 1781 1749 1749

16 1748 1755 1791 1840 1852 1798 1772 1750 1750 1775 1829 1860 1873 1826 1783 1752 1748

17 1747 1757 1794 1847 1860 1802 1777 1748 1748 1774 1828 1865 1878 1839 1786 1753 1747

18 1744 1758 1801 1851 1863 1806 1777 1744 1746 1773 1827 1874 1881 1845 1789 1754 1744

19 1740 1758 1807 1854 1866 1809 1780 1740 1748 1772 1832 1877 1883 1848 1797 1756 1740

20 1736 1755 1811 1859 1868 1811 1783 1741 1748 1774 1840 1880 1882 1853 1803 1753 1736

21 1735 1751 1817 1864 1863 1811 1782 1743 1746 1777 1844 1878 1877 1856 1807 1750 1735

22 1735 1746 1822 1865 1850 1808 1783 1743 1743 1781 1844 1874 1867 1854 1816 1746 1735

23 1733 1743 1823 1856 1836 1799 1783 1742 1742 1779 1846 1871 1850 1851 1819 1744 1733

24 1728 1743 1822 1845 1817 1787 1785 1735 1740 1778 1849 1865 1835 1841 1820 1740 1728

25 1722 1742 1822 1830 1800 1772 1785 1732 1733 1779 1850 1849 1810 1831 1821 1739 1722

26 1718 1739 1824 1814 1778 1751 1788 1730 1729 1777 1850 1833 1789 1810 1819 1736 1718

27 1712 1734 1822 1790 1756 1734 1792 1728 1723 1772 1850 1809 1760 1784 1817 1728 1712

28 1704 1729 1816 1772 1731 1717 1788 1724 1718 1770 1848 1791 1742 1765 1812 1720 1704

29 1690 1722 1812 1748 1700 1700 1779 1718 1711 1762 1839 1762 1715 1744 1810 1717 1690

Page 9: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

9 / 17

30 1684 1713 1806 1729 1678 1673 1766 1713 1705 1755 1832 1736 1686 1724 1802 1710 1684

31 1674 1704 1795 1703 1647 1649 1750 1703 1697 1748 1826 1716 1659 1698 1794 1701 1674

32 1662 1695 1778 1680 1621 1616 1736 1692 1682 1740 1817 1688 1621 1674 1782 1688 1662

33 1645 1686 1763 1648 1593 1585 1723 1676 1664 1725 1801 1666 1593 1645 1766 1675 1645

34 1630 1671 1746 1623 1563 1564 1713 1662 1643 1708 1786 1637 1561 1621 1751 1665 1630

35 1608 1657 1730 1593 1521 1536 1696 1640 1627 1691 1768 1604 1527 1589 1732 1653 1608

36 1587 1637 1707 1565 1491 1507 1675 1623 1600 1669 1739 1573 1497 1562 1713 1638 1587

37 1558 1617 1688 1529 1454 1468 1649 1601 1571 1650 1719 1536 1455 1529 1688 1618 1558

38 1534 1590 1664 1494 1426 1440 1617 1576 1546 1622 1697 1509 1423 1501 1665 1595 1534

39 1499 1564 1640 1466 1385 1405 1593 1552 1509 1590 1669 1473 1387 1464 1638 1559 1499

40 1467 1533 1608 1427 1340 1370 1561 1520 1476 1562 1645 1440 1355 1434 1613 1530 1467

41 1426 1501 1578 1395 1317 1335 1535 1490 1435 1522 1612 1401 1318 1395 1579 1493 1426

42 1388 1462 1541 1359 1288 1291 1503 1454 1392 1490 1582 1365 1284 1357 1552 1462 1388

43 1337 1427 1509 1334 1267 1269 1461 1421 1358 1444 1539 1337 1258 1327 1513 1419 1337

44 1299 1379 1467 1299 1236 1244 1423 1379 1312 1394 1501 1303 1232 1288 1478 1380 1299

45 1249 1329 1421 1272 1208 1218 1376 1334 1271 1352 1454 1273 1208 1262 1433 1326 1249

46 1193 1289 1379 1241 1175 1186 1340 1293 1217 1300 1409 1235 1171 1230 1393 1286 1193

47 1152 1236 1328 1214 1150 1149 1290 1239 1166 1259 1365 1206 1135 1203 1340 1232 1152

48 1101 1190 1288 1179 1114 1120 1242 1184 1129 1202 1304 1183 1111 1170 1301 1185 1101

49 1064 1133 1234 1151 1085 1091 1199 1142 1082 1146 1258 1151 1074 1141 1247 1129 1064

50 1023 1088 1193 1111 1050 1055 1146 1087 1046 1106 1196 1115 1044 1107 1199 1086 1023

51 991 1034 1137 1077 994 1025 1101 1046 1008 1053 1139 1075 975 1077 1143 1032 991

52 955 992 1088 1042 928 980 1050 995 970 1013 1090 1036 918 1033 1085 990 955

53 925 952 1030 968 898 912 1001 949 941 967 1028 980 886 998 1037 958 925

54 879 922 991 915 835 860 956 918 901 928 971 913 818 925 982 914 879

55 769 880 939 871 783 813 905 880 864 894 926 879 772 878 937 882 769

56 685 845 893 815 744 746 861 844 727 852 872 808 730 832 882 832 685

57 654 732 834 754 685 698 812 793 663 812 829 746 658 767 836 732 654

58 524 650 795 716 636 656 761 657 633 679 781 712 625 717 784 642 524

59 478 604 742 639 577 592 720 607 512 614 734 633 560 659 747 609 478

60 416 502 687 603 534 545 645 563 465 582 682 598 525 605 699 502 416

61 321 439 629 537 484 493 605 464 418 463 617 530 466 559 639 446 321

Page 10: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

10 / 17

62 285 354 576 497 440 447 552 409 323 424 580 483 424 500 585 387 285

63 194 294 518 440 385 396 488 338 294 360 517 424 375 455 542 302 194

64 155 227 421 402 351 352 426 275 193 282 432 379 329 403 433 254 155

65 84 170 368 344 295 309 341 232 172 250 363 332 296 355 382 179 84

66 74 99 307 300 264 266 308 166 84 166 319 281 246 319 330 126 74

67 62 73 242 259 219 220 231 119 68 127 247 236 201 270 257 79 62

68 52 61 194 209 176 183 191 68 61 68 209 203 167 238 220 69 52

69 45 51 146 177 141 156 144 60 52 58 147 161 126 196 159 57 45

70 37 44 101 138 107 120 112 51 45 51 122 124 88 155 125 50 37

71 32 36 71 110 80 92 74 43 39 44 80 96 61 125 87 41 32

72 26 31 45 74 53 58 52 38 34 38 51 60 50 88 58 34 26

73 23 26 38 45 47 42 39 33 29 33 42 44 42 62 48 29 23

74 18 22 33 39 39 37 35 28 26 29 36 38 36 48 40 24 18

75 15 18 27 33 33 31 29 25 22 25 31 32 30 42 34 20 15

76 13 14 23 29 28 26 25 21 19 22 27 28 25 35 28 16 13

77 10 12 19 24 23 22 22 19 17 19 23 24 22 30 24 14 10

78 8 9 16 20 20 19 19 16 15 16 20 20 19 26 20 11 8

79 6 8 13 17 17 16 16 14 13 14 18 17 16 21 15 8 6

80 5 6 10 14 15 14 14 12 11 12 15 15 13 18 13 7 5

81 4 5 8 12 12 11 12 10 9 10 13 12 11 15 9 5 4

82 3 3 6 10 10 9 10 8 8 9 11 10 9 12 7 4 3

83 2 2 4 8 8 8 8 7 7 7 9 8 7 10 5 3 2

84 1 2 3 6 6 6 6 6 5 6 7 6 6 8 4 2 1

85 1 1 2 5 5 5 5 4 4 5 5 5 4 6 2 1 1

86 1 1 1 3 4 3 4 3 3 3 4 4 3 4 1 1 1

87 0 0 1 2 2 2 2 2 2 2 2 3 2 2 1 1 0

88 0 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0

89 0 0 0 0 0 1 1 1 1 1 1 1 1 1 1 0 0

90 0 0 0 1 0 1 1 1 1 1 1 1 1 0 0 0 0

91 0 0 0 0 0 1 1 0 1 1 1 1 1 0 1 0 0

92 0 0 0 0 0 1 1 0 1 1 1 1 1 0 0 0 0

93 0 0 0 0 0 1 1 0 0 1 1 1 0 0 0 0 0

Page 11: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

11 / 17

94 0 0 0 0 0 1 1 0 0 0 1 1 0 0 0 0 0

95 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 0

96 0 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0

97 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0

98 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

100 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0

101 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0

102 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

103 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0

104 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0

105 0 0 0 0 0 1 1 0 0 0 1 1 0 0 0 0 0

106 0 0 0 0 0 1 1 0 0 0 1 1 0 0 0 0 0

107 0 0 0 0 0 1 1 0 0 0 0 1 1 0 0 0 0

108 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0

109 0 0 0 0 0 1 1 1 0 1 1 1 1 0 0 0 0

110 0 0 0 0 0 1 1 1 1 1 1 1 0 0 0 0 0

111 0 0 0 0 0 1 1 0 0 1 1 1 1 0 0 0 0

112 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0

113 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0

114 0 0 1 0 0 1 1 1 1 1 1 1 1 0 0 0 0

115 0 1 1 0 0 1 1 1 1 1 1 1 1 0 0 1 0

116 1 0 1 0 0 1 1 1 1 1 1 1 1 1 1 0 1

117 1 0 0 1 0 1 1 1 1 1 1 1 1 0 1 1 1

118 1 0 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1

119 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

120 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

121 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

122 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

123 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

124 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

125 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Page 12: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

12 / 17

126 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

127 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

128 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

129 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

130 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

131 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

132 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

133 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

134 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

135 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

136 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

137 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

138 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

139 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

140 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

141 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

142 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

143 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

144 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

145 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

146 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

147 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

148 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

149 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

150 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1

151 1 1 1 1 1 2 1 1 1 1 1 1 2 1 1 1 1

152 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1

153 1 1 1 1 1 1 1 1 1 2 1 1 2 1 1 1 1

154 1 1 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1

155 1 1 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1

156 2 1 1 1 1 2 1 1 2 1 1 1 2 1 1 1 2

157 1 1 1 1 1 2 1 1 2 2 1 1 2 1 1 1 1

Page 13: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

13 / 17

158 1 1 1 1 1 2 1 1 2 2 1 1 1 1 1 1 1

159 1 1 1 2 1 2 1 1 2 1 1 1 2 1 1 1 1

160 2 1 1 1 1 2 1 1 2 1 1 1 2 1 1 1 2

161 2 1 1 2 1 2 1 1 1 2 1 1 2 1 1 2 2

162 2 1 1 2 1 2 1 1 2 1 1 1 1 1 1 1 2

163 2 1 1 2 1 2 1 2 2 2 1 1 2 1 1 2 2

164 2 1 1 1 1 2 1 2 2 2 1 2 2 1 1 2 2

165 2 1 1 1 1 2 1 2 2 2 1 1 2 1 1 2 2

166 2 2 1 1 1 2 2 2 2 2 1 1 2 2 2 2 2

167 2 2 2 2 1 2 2 2 2 2 2 2 2 1 1 2 2

168 2 2 1 2 1 2 2 2 2 2 2 2 2 2 2 2 2

169 2 2 1 2 1 2 2 2 2 2 1 2 2 2 2 2 2

170 2 2 2 2 1 2 2 2 2 2 2 2 2 2 2 2 2

171 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

172 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

173 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

174 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

175 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

176 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

177 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

178 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

179 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

180 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2

Page 14: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

14 / 17

2.2 Electrical, Photometric and Chromaticity Measurements

(Refer to Work Instruction QD25)

Test date 2017-06-16 Test Ambient: 25.2 º C

Test Orientation As intended Stabilization Time (min) 90

Model Number 57-50W-57K-FL-XT05

Electrical Measurement:

Sample No. Voltage (Vac) Frequency (Hz ) Current (A) Power (W) Power Factor THD %

GZE170606

4-B2

120.0 60 0.3894 46.52 0.9955 8.24

277.0 60 0.1793 45.69 0.9197 15.73

DLC Pass Criteria >= 0.9(-3%) <= 20(+5)

Chromaticity Measurement - Sphere-Spectroradiometer Method:

Parameter Result Special Color Rendering Indices

Test Voltage (V) 120.0 R1 79 R9 0

Frequency (Hz) 60 R2 86 R10 67

CCT (K) 5585 R3 91 R11 79

Duv 0.0040 R4 81 R12 57

Chromaticity (x, y) x=0.3305 y=0.3472 R5 80 R13 81

Chromaticity (u’, v’) u'=0.2032 v'=0.4803 R6 81 R14 95

Color Rendering Index (CRI) 81.5 R7 87 R15 74

R9 0 R8 66 -- --

Photometric Measurement – Sphere-Spectroradiometer Method:

Parameter Result DLC V4.0 Pass Criteria

Test Voltage (V) 120.0 277.0 --

Frequency (Hz) 60 60

Total Luminous (lm) 4725 4625 5000-10000(-10%)

Luminous Efficacy (lm/W) 101.57 101.23 Standard: >=

95(-3%)

Premium: >=

115(-3%) Most Worst Luminous/Highest Watts 99.42

Page 15: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

15 / 17

Spectral Power Distribution & Chromaticity Diagram

Page 16: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

16 / 17

2.3 Performance Assessment:

Model name CCT(K) Total Luminous

(lm) Power (W)

Luminous

Efficacy (lm/W)

57-50W-40K-FL-XT05 4000K 4626.3 46.30 99.92

57-50W-50K-FL-XT05 5000K 4692*1

46.41*2

101.10*3

57-50W-57K-FL-XT05 5700K 4725 46.52 101.57

*1: This value is calculated and the calculation formula is as below:

4692=(4725-4626.3)/3+4659

*2: This value is calculated and the calculation formula is as below:

46.41=(46.30+46.52)/2

*3: This value is calculated and the calculation formula is as below:

101.10=4692/46.41

Page 17: LM-79-08 Test Report › cf73a1a2 › files... · 9 1761 1766 1778 1795 1799 1760 1757 1750 1760 1777 1792 1813 1815 1773 1768 1758 1761 10 1757 1765 1780 1798 1806 1763 1758 1750

STANDARD-TECH Report No.: GZE1706064-B-R

Laboratory: Standard-Tech Co. Ltd Testing Center

NVLAP CODE: 201011-0

Report Format Number STD/QR4909-A/2

Address:Standard-Tech Building, No.6 Guanhong Road,Guangzhou Science City, Guangzhou 510663, China

Tel: 8620-3229 0320 Fax: 8620-32290422 http://www.standard-tech.com

17 / 17

3. Test Equipment

Equipment ID Equipment Name Last Calibration Date Next Calibration Date

ST-R-331 2 meter Integrating Sphere 2016-07-01 2017-06-30

ST-R-327 Spectral analysis system HAAS-2000 2016-07-01 2017-06-30

D204 Standard Lamp 2016-07-12 2017-07-11

PF2010 Power Meter for Integrating Sphere 2016-07-01 2017-06-30

GO-R5000 Goniophotometer system 2016-07-01 2017-06-30

D908S Standard Lamp 2016-07-12 2017-07-11

PF210 Power Meter for Goniophotometer 2016-07-07 2017-07-06

Expand Uncertainty:

Photometric Measurement (Sphere):2.04%, k=2

Chromaticity Measurement(Sphere):28.8K, k=2

Photometric Measurement(Goniophotometer):2.36%, k=2

****** END OF REPORT ******