Hach Lange Liquid Analytics Standard configurations

1

Page 2: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

2

The information provided in this document contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. No responsibility is taken for the correctness of this information. This document provides application examples of Hach Lange liquid analytic equipment, however more applications and configurations are possible. Contact: Christian Pust Alliance Manager Hach Lange I IA SC S PI IB-2 Phone ++49 721 595 6893 [email protected]

Page 3: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

3

Table of content

1. Water / Waste Water Applications ......................................................................................... 4 1.1 pH Measurement in WWW applications ................................................................................4 1.2 ORP Measurement in WWW applications .............................................................................9 1.3 Conductivity Measurement in WWW applications ...............................................................11 1.4 Dissolved Oxygen Measurement in WWW applications .....................................................13 1.5 Turbidity / Solid measurement in WWW applications..........................................................15 1.6 Multi parameter system for Drinking Water .........................................................................19 1.7 Oil in Water ...........................................................................................................................20 1.8 Nitrate measurement in WWW applications ........................................................................21 1.9 Ammonia measurement in WWW applications....................................................................23 1.10 Ammonia and Nitrate measurement in WWW applications...............................................26 1.11 Phosphate measurement in WWW applications ...............................................................27 1.12 Sludge / Solid interface level measurement in WWW applications...................................28 1.13 Chlorine in WWW applications...........................................................................................29 1.14 Chlorine Dioxide and Ozone in WWW applications...........................................................32 1.15 TOC in WWW applications.................................................................................................32

2. Industrial Applications.......................................................................................................... 34

2.1 pH measurement in industrial applications ..........................................................................34 2.2 ORP measurement in industrial applications.......................................................................39 2.3 Conductivity measurement in industrial applications...........................................................40 2.4 Oxygen dissolved (DO) and Gas measurement in industrial applications ..........................40 2.5 Silica measurement in industrial applications ......................................................................52 2.6 Sodium measurement in industrial applications ..................................................................54 2.7 Turbidity/ Solid measurement in industrial applications ......................................................56 2.8 Hydrazine / Oxygen Scavenger in industrial applications ..................................................60 2.9 Phosphate in industrial applications.....................................................................................61 2.10 Dissolved Ozone in industrial applications ........................................................................62 2.11 Hydrogen measurement in industrial applications.............................................................63 2.12 Dissolved Carbon Dioxide measurement in industrial applications ..................................65 2.13 Dissolved Nitrogen measurement in industrial applications ..............................................67

2.14 Oil in Water in industrial applications…………………………………………………………69 2.15 TOC in industrial applications…………………………………………………………………70

Page 4: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

4

1. Water / Waste Water Applications

1.1 pH Measurement in WWW applications

pH Measurement, 4-20mA Output Application example: low budget / low cost, standard water applications Comment: Panel mount, cost effective, flow thru DXX:LXV2702.98.0002 Si627P, panel mount 96x96mm, 230VAC, 1x 0/4-20 mA output DXX:LZU5300.97.0002 pH electrode, S8 connector DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZU6006.99 Flow thru cell, 2Sensors, flow detection, 6 bar, max. 45°C

pH Measurement, 1200S sc, 4-20mA Output, Immersion Application example: municipal waste water, Inlet waste water treatment plant, Aeration tank, SBR, Nitrification/Denitrification, Digester, Effluent, fish farm Comment: SC technology, dedicated waste water pH sensor, immersion, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV426.99.10001 1200-S sc Digital pH sensor, includes built-in digital electronics,

a replaceable 12mm pH combination polymer electrode, integral 10 m cable terminated with connector for the sc digital controller series

DXX:LZX914.99.12200 Chain Mount Kit (CPVC) for E-Chem sensors, simply installation on basin rim (railing or concrete wall), immersion depth adjustable

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

pH Measurement, pHD S sc, 4-20mA Output, Immersion Application example: municipal waste water, Inlet waste water treatment plant, Aeration Basin, SBR, Nitrification/Denitrification, Digester, Effluent Comment: SC technology, dedicated waste water pH sensor with pHD technology, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV427.99.10001 pHD S sc Digital pH sc sensor, pHD Differential; Immersion type,

stainless steel body, Ryton; measuring range 0..14 pH; integrated Temperature Sensor (NTC300); built-in digital electronics and fixed 10 m cable terminated with connector for sc digital controller series

DXX:LZX914.99.12200 Chain Mount Kit (CPVC) for E-Chem sensors, simply installation on basin rim (railing or concrete wall), immersion depth adjustable

Page 5: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

5

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

pH Measurement, pHD sc, 4-20mA Output, 1” T piece process connection Application example: water general, drinking water, municipal waste water, industrial waste water Comment: SC technology, pH sensor with pHD technology, flow throu DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA Outputs, 4x Relays, 24VdC

power supply DXX:DPD1P1.99 pHD sc Digital pH sc sensor, pHD Differential; Glass for General

Purpose, Convertible – 1-inch NPT threads at both ends; PEEK (Polyetheretherketone); measuring range 0 .. 14 pH; integrated Temperature Sensor (NTC300); Operating temperature 0...70°C; Pmax 6,9 bar, @ 70°C. include built-in digital electronics and integral 10 m cable, terminated with connector for the sc digital controller

DXX:MH334N4NZ 1" T piece, for 1 inch NPT electrode, CPVC

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

pH Measurement, LZU5334T, 4-20mA Output, immersion installation Application example: water general, drinking water, municipal waste water, industrial waste water, fish farm Comment: immersion DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5334T.97.002 pH electrode 5334T, for high solid concentration, integrated T-sensor, diameter

12mm, MP4 sensor connector DXX:LZU9302.99 cable for pH electrode with MP4 connector, length 10m DXX:LZU230.99.11412 chain mount

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

pH Measurement, LZU5334T, Profibus PA, ATEX, immersion installation Application example: municipal waste water, Intrinsic safe areas, industrial waste water Comment: loop powered, Profibus PA, ATEX, immersion DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6 DXX:LZU5334T.97.002 pH electrode 5334T, for high solid concentration, integrated T-sensor, diameter

12mm, MP4 sensor connector DXX:LZU9302.99 cable for pH electrode with MP4 connector, length 10m DXX:LZU230.99.11412 chain mount

Page 6: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

6

pH Measurement, pHD sc, 0/4-20mA Output, Inline retractable process connection Application example: Digestor on waste water treatment plant Comment: pHD electrode, inline retractable DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA Outputs, 4x Relays, 24VdC

power supply DXX:DPD1P1.99 pHD sc Digital pH sc sensor, pHD Differential; General Purpose Glass,

Convertible – 1-inch NPT threads at both ends; PEEK (Polyetheretherketone); measuring range -2...14 pH; integrated Temperature Sensor (NTC300); Operating temperature 0...70°C; Pmax 6,9 bar @ 70°C, built-in digital electronics and fixed 10 m cable terminated with connector for sc digital controller series

DXX:6136800 Insertion Mount for pHD sc sensors, 316SS, includes 1-1/2 inch ball valve 316SS, 1-1/2 inch NPT close nipple, sensor adapter with two Viton® O-rings and wiper, extension pipe, pipe adapter, back tube, lock ring

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

pH measurement, LZU5334T, 4-20mA Output, Inline insertion fitting Application example: Digestor on waste water treatment plant Comment: Inline insertion, recommended configuration if fits to specifications DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5334T.97.002 pH electrode 5334T, for high solid concentration, integrated T-sensor, diameter

12mm, MP4 sensor connector DXX:LZU9302.99 cable for pH electrode with MP4 connector, length 10m DXX:LZU7801.99 insertion/pipe mount fitting, retractable, stainless steel, type In78, max 130°C,

PG13,5, DN25 connection for weld in socket DXX:LZU6122.99 Weld-in-socket, SS, inclined 15º for fitting In 77 and In 78 pH measurement, LZU5334T, 4-20mA Output, HART, ATEX, Inline insertion fitting Application example: Digestor on waste water treatment plant

Intrinsic safe areas Comment: loop powered, HART, ATEX, inline insertion DXX:LXV500.99.70102 Si792P, pH/ORP transmitter, loop powered, HART, ATEX II 2 (1)G Eex ib (ia) IIC

T6, 24VdC, 1x 0/4-20mA Output DXX:LZU5334T.97.002 pH electrode 5334T, for high solid concentration, integrated T-sensor, diameter

12mm, MP4 sensor connector DXX:LZU9302.99 cable for pH electrode with MP4 connector, length 10m DXX:LZU7801.99 insertion/pipe mount fitting, retractable, stainless steel, type In78, max 130°C,

PG13,5, DN25 connection for weld in socket DXX:LZU6122.99 Weld-in-socket, SS, inclined 15º for fitting In 77 and In 78 Option Profibus PA, ATEX DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6

Page 7: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

7

pH measurement, LZU5334T, 4-20mA Output, HART, ATEX, Inline retractable fitting Application example: Intrinsic safe areas Comment: loop powered, HART, ATEX, inline retractable DXX:LXV500.99.70102 Si792P, pH/ORP transmitter, loop powered, HART, ATEX

II 2 (1)G Eex ib (ia) IIC T624VdC, 1x 0/4-20mA Output DXX:LZU5334T.97.002 pH electrode 5334T, for high solid concentration, integrated T-sensor, diameter

12mm, MP4 sensor connector DXX:LZU9302.99 cable for pH electrode with MP4 connector, length 10m DXX:LZY236 Retractable fitting for inline installation and for mounting on vessels, made of

Stainless steel 1.4571, polyamide (PA) housing, Viton (FPM) gaskets, Pmax 4bar, Tmax 90°C, process connection thread G1 1/4”, for sensors with 120-mm shaft length, 12mm diameter and PG13,5 thread

DXX:LZY234 Welding-type connector, angled 15°, made of stainless steel (mat. No. 1.4571), connection G1 1/4”

Option Profibus PA, ATEX DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6 pH measurement, LZU5336T, 0/4-20mA, flow thru cell Application example: Process water in general, Drinking water treatment, Inlet (raw water), flocculation, disinfection, clean water Comment: Panel mount, cost effective, flow throu

DXX:LXV2702.98.0002 Si627P, panel mount 96x96 mm, 230VAC, 1x mA output DXX:LZU5336T.97.002 pH electrode for normal process conditions, diameter 12mm,

length 120mm, PG13,5, MP4 plug, with temp. sensor

DXX:LZU9301.99 cable, length 5 m, with MP4 sensor plug, IP67 DXX:LZU6006.99 Flow thru cell, 2Sensors, flow detection, 6 bar, max. 45°C pH measurement, LZU5336T, 0/4-20mA, flow thru cell Application example: Process water in general, Drinking water treatment, Inlet (raw water), flocculation,

disinfection, clean water Comment: flow throu, recommended configuration if fits to specifications

DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5336T.97.002 pH electrode for normal process conditions, diameter 12mm, length

120mm, PG13,5, MP4 plug, with temp. sensor DXX:LZU9301.99 cable, length 5 m, with MP4 sensor plug, IP67 DXX:LZU6006.99 Flow thru cell, 2Sensors PG13,5, flow detection, 6 bar, max. 45°C pH measurement, LZU5336T, Profibus PA, flow thru cell Application example: Process water in general, Drinking water treatment, Inlet (raw water), flocculation, disinfection, clean water Comment: Profibus PA, ATEX, flow throu DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6 DXX:LZU5336T.97.002 pH electrode for normal process conditions, diameter 12mm, length

Page 8: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

8

120mm, PG13,5, MP4 plug, with temp. sensor DXX:LZU9301.99 cable, length 5 m, with MP4 sensor plug, IP67 DXX:LZU6006.99 Flow thru cell, 2 Sensors PG13,5, flow detection, 6 bar, max. 45°C pH measurement, LZX537, 4-20 mA, flow throu cell Application example: Drinking water, cold/low conductivity (<100µS/cm) Comment: Panel mount, cost effective, flow throu DXX:LXV2702.98.0002 Si627P, panel mount 96x96 mm, 230 VAC, 1x 0/4.. 20 mA output DXX:LZX537 pH electrode, integrated temp sensor, TOP68 connector, cold water / low

conductivity (<100μS, -20 to +50°C) DXX:LZX548 cable 5m, TOP68 connector DXX: LZU6006.99 Flow thru fitting, 2 Sensors, flow detection, 6bar, max.45°C pH measurement, LZX537, 4-20 mA Application example: Drinking water, cold/low conductivity (<100µS/cm) Comment: flow throu DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZX537 pH electrode, integrated temp sensor, TOP68 connector, dedicated for cold

water and low conductivity (<100μS, -20…+50°C) DXX:LZX548 cable 5m, TOP68 connector DXX: LZU6006.99 Flow thru fitting, 2 Sensors PG13,5, flow detection, 6bar, max.45°C

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 9: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

9

1.2 ORP Measurement in WWW applications

ORP Measurement, LZU5358, 4-20mA Application example: low budget / low cost, standard water applications, drinking water, pool water Comment: Panel mount, cost effective, flow throu, electrode is not recommended for water with low conductivity, colloids, particles or suspensions DXX:LXV2702.98.0002 Si627P, panel mount 96x96 mm, 230VAC, 1x 0/4-20 mA output DXX: LZU5358.97.0002 ORP Elektrode 5358 with PG13,5 L 120mm, D 12mm, connector and fixed cable

5m, 0-80°C, Pmax 5bar, pH 0-14, for pool and drinking water, 1x ceramic diaphragm

DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZU6006.99 Flow thru cell, 2Sensors PG13,5, flow detection, 6 bar, max. 45°C ORP measurement, LZU5353, 4-20mA, flow thru cell Application example: Process water in general, Drinking water treatment, Inlet (raw water), flocculation, disinfection, clean water Comment: flow throu, recommended configuration if fits to specifications

DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5353.97.0002 ORP electrode 5353, S8 connector, PG13,5, L 120mm, D 12mm, ceramic

diaphragm, reference electrode protected by internal ceramic diaphragm DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZU6006.99 Flow thru cell, 2Sensors PG13,5, flow detection, 6 bar, max. 45°C Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

ORP Measurement, 1200 S sc, 4-20mA, Immersion Application example: Aeration tank waste water treatment plant, fish farm Comment: SC technology, dedicated waste water ORP sensor, immersion, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV426.99.20001 1200-S sc Digital ORP sensor, includes built-in digital electronics,

a replaceable 12mm ORP combination polymer electrode, integral 10 m cable terminated with connector for the sc digital controller series

DXX:LZX914.99.12200 Chain Mount Kit (CPVC) for E-Chem sensors, simply installation on basin rim (railing or concrete wall), immersion depth adjustable

Option Profibus DP:

Page 10: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

10

DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x Relays, 24VdC power supply

ORP Measurement, pHD S sc ORP, 4-20mA Output, Immersion Application example: Aeration tank waste water treatment plant Comment: SC technology, dedicated waste water pH sensor with pHD SC electrode, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV427.99.20001 pHD S sc Digital ORP sc sensor, pHD Differential; Immersion type,

stainless steel body, Ryton; integrated Temperature Sensor (NTC300); built-in digital electronics and fixed 10 m cable terminated with connector for sc digital controller series

DXX:LZX914.99.12200 Chain Mount Kit (CPVC) for E-Chem sensors, simply installation on basin rim (railing or concrete wall), immersion depth adjustable

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 11: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

11

1.3 Conductivity Measurement in WWW applications

Conductivity Measurement, Graphite, flow thru Application example: general water Comment: Panel mount, cost effective, flow thru DXX:LXV3902.98.0002 si629C, conductivity transmitter, panel mount 96x96 mm, 4-20mA output, 3

relays, 230 V AC DXX:LZY082 2 EL contacting conductivity sensor, 2 Graphite electrodes, measuring range 1

µS/cm.. 2500 µS/cm, PG 13,5 threat, 5 m fixed cable, installation length 120 mm, 12 mm Ø, shaft material UDEL (PSU), measuring electrodes Graphite, cell constant 1,0 cm-1, Sealing material EPDM, protection class IP 68, integrated Pt 1000, operation temperature -5...80°C, pressure range: 0...6 bar

DXX: LZU6002.99 Flow-thru chamber, type CR60, PP and Noryl, for 2 PG13,5 sensors, max Temp. 45°C, max 6bar, 6/8 mm tube joints

Conductivity Measurement, Graphite, flow thru Application example: general water Comment: Wall mount, cost effective, flow thru DXX:LXV3900.98.0002 si629C, conductivity transmitter, wall-mount, 4-20mA output, 3 relays, 230 V AC DXX:LZY082 2 EL contacting conductivity sensor, 2 Graphite electrodes, measuring range 1

µS/cm.. 2500 µS/cm, PG 13,5 threat, 5 m fixed cable, installation length 120 mm, 12 mm Ø, shaft material UDEL (PSU), measuring electrodes Graphite, cell constant 1,0 cm-1, Sealing material EPDM, protection class IP 68, integrated Pt 1000, operation temperature -5...80°C, pressure range: 0...6 bar

DXX: LZU6002.99 Flow-thru chamber, type CR60, PP and Noryl, for 2 PG13,5 sensors, max Temp. 45°C, max 6bar, 6/8 mm tube joints

Conductivity Measurement, Graphite, flow thru Application example: general water Comment: flow thru, recommended configuration if fits to specifications DXX :LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:LZY082 2 EL contacting conductivity sensor, 2 Graphite electrodes, measuring range 1

µS/cm.. 2500 µS/cm, PG 13,5 threat, 5 m fixed cable, installation length 120 mm, 12 mm Ø, shaft material UDEL (PSU), measuring electrodes Graphite, cell constant 1,0 cm-1, Sealing material EPDM, protection class IP 68, integrated Pt 1000, operation temperature -5...80°C, pressure range: 0...6 bar

DXX: LZU6002.99 Flow-thru chamber, type CR60, PP and Noryl, for 2 PG13,5 sensors, max Temp. 45°C, max 6bar, 6/8 mm tube joints

Conductivity Measurement, Graphite, Inline Application example: general water, insertion/inline/pipe mount with weld on, recommended configuration if fits to specifications DXX :LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:LZY082 2 EL contacting conductivity sensor, 2 Graphite electrodes, measuring range 1

µS/cm, to 2500 µS/cm, PG 13,5 threat, 5 m fixed cable, installation length 120 mm, 12 mm Ø, shaft material UDEL (PSU), measuring electrodes Graphite, cell

Page 12: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

12

constant 1,0 cm-1, Sealing material EPDM, protection class IP 68, integrated Pt 1000, operation temperature -5...80°C, pressure range: 0...6 bar

LZU7801.99 insertion/pipe mount fitting, retractable, stainless steel, type In78, max 130°C, PG13.5, DN25 connection for weld in socket

DXX:LZU6122.99 Weld-in-socket, SS, inclined 15º for fitting In 77 and In 78

Conductivity Measurement, Platinum, flow thru Application example: general water, insertion/inline/pipe mount with weld on, recommended configuration if fits to specifications DXX :LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:LZU5396.97.0002 2EL contacting conductivity sensor, meas. Range 1µS/cm…200mS/cm, temp

0…80°C, max. 2bar, PG13,5 process connector, electrode material platinum, shaft material glass, S8 head connector

DXX:LZU5396.97.0002 cable 5m with MP5 connector, IP67 DXX: LZU6002.99 Flow-thru chamber, type CR60, PP and Noryl, for 2 PG13,5 sensors, max

Temp. 45°C, max 6bar, 6/8 mm tube joints

Conductivity Measurement, Platinum, Inline Application example: general water, insertion/inline/pipe mount with weld on, recommended configuration if fits to specifications DXX :LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:LZU5396.97.0002 2EL contacting conductivity sensor, meas. Range 1µS/cm…200mS/cm, temp

0…80°C, max. 2bar, PG13,5 process connector, electrode material platinum, shaft material glass, S8 head connector

DXX:LZU7801.99 insertion/pipe mount fitting, retractable, stainless steel, type In78, max 130°C, PG13,5, DN25 connection for weld in socket

DXX:LZU6122.99 Weld-in-socket, SS, inclined 15º for fitting In 77 and In 78

Conductivity Measurement, 3798 S sc, 4-20mA Output, Immersion Application example: Inlet waste water treatment plant, general water treatment Comment: SC technology, dedicated waste water conductivity sensor, immersion, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV428.99.00001 3798 S sc Digital Inductive conductivity sensor, integrated Pt100, measuring

range 250 μS/cm ... 2,5 S/cm, immersion style, stainless steel housing, sensor PEEK, 10m fixed cable

DXX:LZX985 Electrical Calibration tool for 3798-S sc DXX:LZX914.99.12200 Chain Mount Kit (CPVC) for E-Chem sensors, simply

installation on basin rim (railing or concrete wall), immersion depth adjustable

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 13: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

13

1.4 Dissolved Oxygen Measurement in WWW applications Dissolved Oxygen measurement, Flow fitting Application example: General process water Comment: electrochemical sensor, cost effective, flow fitting DXX:LXV508.99.00002 Si794D si794 Transmitter for dissolved oxygen measurement, variable power

supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets,

DXX:LZY078 OXYSENS dissolved oxygen sensor for ATEX Zone 1, 5m sealed and fixed cable, maintenance-free disposable sensor, with integrated 22 kOhm NTC thermistor, suitable for waste water and water applications, e.g. fish farming etc., Meas. range 40 μg/l ... 20 mg/l, up to 4 bar and 0 ... 60°C, with 3.1B certificate, EXLabel: II 1/2G EEx IA II C T4/T5/T6, ATEX No: TUV 03 ATEX 7005X, PG13,5 Thread, Sealing material: EDPM, 120mm shaft length, 12mm diameter, made of SS 1.4435, low drift for reliable measurements and fast response

DXX:LZU6006.99 Flow thru cell, 2Sensors PG13,5, flow detection, 6 bar, max. 45°C

Dissolved Oxygen Measurement, LDO, 4-20mA Output, Immersion Application example: Water treatment, Aeration tank waste water treatment plant, fish farm, Drinking water Comment: SC technology, LDO technology, dedicated waste water dissolved oxygen sensor, immersion, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV416.99.00001 Lange LDO Dissolved Oxygen Sensor, luminescence-time detection

technology, calibration-free, H2S-resistant, integrated T-Sensor NTC30, meas. range 0,1 … 20mg/l, 0 … 200% Sat., immersion style, 10m fixed cable

DXX:LZX914.99.12200 Chain Mount Kit (CPVC) for E-Chem sensors, simply installation on basin rim (railing or concrete wall), immersion depth adjustable

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Dissolved Oxygen Measurement, LDO, 4-20mA Output, Flow fitting Application example: General Water, Drinking Water treatment Comment: SC technology, LDO technology, dedicated waste water dissolved oxygen sensor, flow throu fitting, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation

Page 14: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

14

DXX:LXV416.99.00001 Lange LDO Dissolved Oxygen Sensor, luminescence-time detection technology, calibration-free, H2S-resistant, integrated T-Sensor NTC30, meas. range 0,1 … 20mg/l, 0 … 200% Sat., immersion style, 10m fixed cable

DXX:7300700 Flow cell for LDO Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Dissolved Oxygen Measurement, Galvanic 5740sc, 4-20mA Output, Immersion Application example: Water treatment, Aeration tank waste water treatment plant, fish farm Comment: SC technology, electrochemical sensor, dedicated waste water DO sensor, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV425.99.00001 5740 sc Digital Galvanic DO Sensor, immersion style, Noryl, replaceable

membrane cartridge, integrated NTC30, meas. Range 0-40 mg/l, 0-200%, Temp. 0…50°C, integral 10 m cable

DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole 1.8m, Socket, Weather guard and UV shield for outdoor installation

DXX:LZX914.99.12200 Chain Mount Kit (CPVC) for E-Chem sensors, simply installation on basin rim (railing or concrete wall), immersion depth adjustable

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 15: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

15

1.5 Turbidity / Solid measurement in WWW applications

Turbidity Measurement, 1720E, USEPA, bypass Application example: Drinking water medium and low range Comment: USEPA approved method with 1720E, for US countries, bypass installation DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LPV417.99.00002 1720E sc, Turbidity sensor, with 2m connection cable, nephelometric

measurement acc. USEPA Method 180.1 (using Tungsten lamp) for drinking water compliance, meas. Range 0,0001…100NTU, Bypass installation with non pressurized outlet, wall mounting, sample inlet ¼" NPT female thread, Drain outlet ½" NPT female, ½" hose barb, sample flow 250 ... 750 ml/min, IP66

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Turbidity Measurement, Ultraturb, EN ISO 7027, bypass Application example: Drinking water medium and low range Comment: EN ISO method with Ultraturb sc, for EU countries, bypass installation DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LPV415.99.20001 Ultraturb sc, Turbidity sensor, with 5m connection cable, nephelometric

measurement acc. EN ISO 7027, meas. range 0,0001…1000FNU, bypass installation, Pmax 6bar, wall mounting, IP65

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Turbidity Measurement, FilterTrak, Filter control, bypass Application example: Drinking water (ultra) low range Comment: Detect changes in turbidity as low as 0.0005 NTU, bypass installation DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LPV421.99.00002 FilterTrak 660sc, light source Class 1 Laser 10 mW, 660 nm, 0,001…

5000mNTU, bypass installation, ambient pressure outlet, wall mount wall mounting, sample inlet ¼" NPT female thread, Drain outlet ½" NPT female, ½" hose barb, sample flow 100 ... 750 ml/min

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 16: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

16

Turbidity measurement, high range, SS7sc, bypass Application example: Drinking water treatment; Inlet; Raw water from river or lake Comment: Non-contacting technology, bypass, Tungsten lamp acc. USEPA180.1, ASTM D 6698; Standard Methods 2130B DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LPV431.99.0002 Surface Scatter SS7sc, High range bypass turbidimeter, 0… 50°C, 0.1…9999.9

NTU, 2m sc connection cable Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Turbidity / Solid measurement, SOLITAX inline sc, 0..50g/l, retractable inline Application example: Drinking water filter control, Waste water return sludge, primary and secondary settling tank Comment: Inline installation, EN 7027 method, concentration of suspended solids (sludge concentration), meas. range 0,001… 50 g/l LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LXV424.99.00100 Solitax inline sc, Inline installation, incl. wiper cleaning, media temp 2… 40°C,

Pmax 5 bar, 0.001…4000 FNU, 0,001.. 50 g/l, 2m sc connection cable DXX:LZX337 Retractable fitting, stainless steel, for insertion and removal of sensor at

pressurized pipe, Pmax 5bar, pipe connection flange DN65, PN16, DIN 2633 Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option connection to pipe: DXX:LZX660 weld on flange for retractable fitting, stainless steel DXX:LZX661 weld on flange for retractable fitting, carbon steel Turbidity / Solid measurement, SOLITAX inline sc, 0..50g/l, ball valve inline Application example: Drinking water filter control, Waste water return sludge, primary and secondary settling tank Comment: Inline installation, EN 7027 method, Turbidity measurement / concentration of suspended solids (sludge concentration), meas. range 0,001… 50 g/l LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LXV424.99.00100 Solitax inline sc, Inline installation, incl. wiper cleaning, media temp 2… 40°C,

Pmax 5 bar, 0.001…4000 FNU, 0,001.. 50 g/l, 2m sc connection cable DXX:LZX337 fitting with ball valve, for insertion and removal of sensor at non-pressurized

filled pipe, Pmax 1bar, pipe connection flange DN65, PN16, DIN 2633 Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option connection to pipe: DXX:LZX660 weld on flange for retractable fitting, stainless steel DXX:LZX661 weld on flange for retractable fitting, carbon steel

Page 17: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

17

Turbidity / Solid measurement, SOLITAX highline sc, 0…500 g/l, retractable inline Application example: Waste water return sludge, primary and secondary settling tank Comment: Inline installation, EN 7027 method, concentration of suspended solids (sludge concentration), meas. range 0,001… 500g/l LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LXV424.99.00200 Solitax sc, Inline installation, incl. wiper cleaning, media temp 2… 40°C, Pmax 5

bar, 0.001…4000 FNU, 0,001.. 500 g/l, 2m sc connection cable DXX:LZX337 Retractable fitting, stainless steel, for insertion and removal of sensor at

pressurized pipe, Pmax 5bar, pipe connection flange DN65, PN16, DIN 2633 Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option connection to pipe: DXX:LZX660 weld on flange for retractable fitting, stainless steel DXX:LZX661 weld on flange for retractable fitting, carbon steel Turbidity / Solid measurement, SOLITAX highline sc, 0..500g/l, ball valve, inline Application example: Waste water return sludge, primary and secondary settling tank Comment: Inline installation, EN 7027 method, concentration of suspended solids (sludge concentration), meas. range 0,001… 500g/l LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LXV424.99.00200 Solitax sc, Inline installation, incl. wiper cleaning, media temp 2… 40°C, Pmax 5

bar, 0.001…4000 FNU, 0,001.. 500 g/l, 2m sc connection cable DXX:LZX337 fitting with ball valve, for insertion and removal of sensor at non-pressurized

filled pipe, Pmax 1bar, pipe connection flange DN65, PN16, DIN 2633 Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option connection to pipe: DXX:LZX660 weld on flange for retractable fitting, stainless steel DXX:LZX661 weld on flange for retractable fitting, carbon steel Turbidity measurement, SOLITAX t-line sc, immersion Application example: Waste water treatment plant outlet Comment: Immersion installation, EN 7027 method LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV423.99.10000 Solitax t-line sc, sensor material PVC, Immersion installation, incl. wiper

cleaning, media temp 2… 40°C, 0.001…4000 FNU, 10 m sc connection cable DXX:LZX414.00.10000 Mounting Assembly Kit "Rim Mounting", Stainless Steel, with 90° adapater

for fixing of SOLITAX to a tank or channel Option Profibus DP:

Page 18: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

18

DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x Relays, 24VdC power supply

Turbidity / Solid measurement, SOLITAX ts-line sc, 0.. 50g/l, immersion Application example: Waste water treatment plant, medium solid concentration Comment: Immersion installation, EN 7027 method LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV423.99.00100 Solitax ts-line sc, sensor material stainless steel, Immersion installation, incl.

wiper cleaning, media temp 2… 40°C, 0.001…4000 FNU, 0,001..50 g/l, 10 m sc connection cable

DXX:LZX414.00.10000 Mounting Assembly Kit "Rim Mounting", Stainless Steel, with 90° adapater for fixing of SOLITAX to a tank or channel

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Turbidity / Solid measurement, SOLITAX hs-line sc, 0.. 500g/l, immersion Application example: Waste water treatment plant, high sludge concentration, aerated sludge Comment: Immersion installation, EN 7027 method LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC

power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV423.99.00200 Solitax hs-line sc, sensor material stainless steel, Immersion installation, incl.

wiper cleaning, media temp 2… 40°C, 0.001…4000 FNU, 0,001..500 g/l, 10 m sc connection cable

DXX:LZX414.00.10000 Mounting Assembly Kit "Rim Mounting", Stainless Steel, with 90° adapater for fixing of SOLITAX to a tank or channel

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 19: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

19

1.6 Multi parameter system for Drinking Water

pH, Conductivity, DO, Turbidity Measurement ISO, Panel Application example: Drinking water Comment: ISO approved method with Ultraturb, Multi Parameter Panel DXX:LZY602.99.1J001 Panel model 75, Turbidity Ultraturb plus SC, pH, Temp, Conductivity and

Dissolved oxygen measurement with LDO technology, central inlet, 3 ball valves separate controlled, 750x1000x130/260mm,

DXX:LXV402.99.00001 sc1000 Display module DXX:LXV400.99.2R321 sc1000 probe module for 4 sc sensors, 100…240 VAC, 1 relay card with 4

relays, 2 analog Output cards with 8 0/4..20mA Output Option Profibus DP: DXX:LXV400.99.2E021 sc1000 probe module for 4 sc sensors, 100…240 VAC, Profibus DP

pH, Conductivity, DO, free Chlorine, Turbidity Measurement ISO, Panel Application example: Drinking water Comment: ISO approved method with Ultraturb, Multi Parameter Panel DXX:LZY601.99.1J101 Panel model 120, Turbidity Ultraturb plus SC, pH, Temp, Conductivity, Dissolved

oxygen measurement with LDO technology, 9184sc free chlorine, central inlet, 1200x1000x130/260mm,

DXX:LXV402.99.00001 sc1000 Display module DXX:LXV400.99.2R331 sc1000 probe module for 6 sc sensors, 100…240 VAC, 1 relay card with 4

relays, 2 analog Output cards with 8 0/4..20mA Output Option Profibus DP: DXX:LXV400.99.2E031 sc1000 probe module for 6 sc sensors, 100…240 VAC, Profibus DP

pH, Conductivity, DO, free Chlorine, Turbidity Measurement ISO, Nitrate, Panel Application example: Drinking water Comment: ISO approved method with Ultraturb, Multi Parameter Panel DXX:LZY601.99.1J111 Panel model 120, Turbidity Ultraturb plus SC, pH, Temp, Conductivity, Dissolved

oxygen measurement with LDO technology, 9184sc free chlorine, Nitrate NITRATAX sc, central inlet, 1200x1000x130/260mm

DXX:LXV402.99.00001 sc1000 Display module DXX:LXV400.99.2R331 sc1000 probe module for 6 sc sensors, 100…240 VAC, 1 relay card with 4

relays, 2 analog Output cards with 8 0/4..20mA Output

Option Profibus DP: DXX:LXV400.99.2E031 sc1000 probe module for 6 sc sensors, 100…240 VAC, Profibus DP

Page 20: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

20

1.7 Oil in Water

Oil in Water, 4-20mA Output, 50/500ppb, Immersion Application example: general detection of oil contamination of water, Inlet of drinking water plant, Inlet of waste water treatment plant, detect oil contamination on rain water channels of industrial facilities or petrochemical plants Comment: SC technology, UV flurometric measurement, ppb level sensitivity, not influenced by particles, detects dissolved and emulgated oil DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV441.99.11101 FP 360sc fluerescence sensor for Oil/PAK, meas range 0…50/500 ppb (PAK

calibation standard), stainless steel housing, 10m cable DXX:LZX914.99.11110 Chain mount, stainless steel, for rail or tank rim fixing Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Oil in Water, 4-20mA Output, 500/5000ppb, Immersion Application example: Detection of contamination of water, Inlet of drinking water plant, Inlet of waste water treatment plant, detect oil contamination on rain water channels of industrial facilities or petrochemical plants Comment: SC technology, UV flurometric measurement, ppb level sensitivity, not influenced by particles, detects dissolved and emulgated oil DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV441.99.21101 FP 360sc fluerescence sensor for Oil/PAK, meas range 0…500/5000 ppb

(PAK calibation standard), stainless steel housing, 10m cable DXX:LZX914.99.11110 Chain mount, stainless steel, for rail or tank rim fixing Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 21: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

21

1.8 Nitrate measurement in WWW applications

Nitrate in Water, Nitratax clear sc, 0,5…20mg/l, 4-20mA Output, flow throu Application example: Nitrate monitoring in drinking water Comment: SC technology, UV measurement, flow throu, meas range 0,5…20 mg/l NO2+3-N, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV420.99.50001 Nitratax clear sc, meas gap 5mm, meas range 0,5…20 mg/l NO2+3-N, UV

absorption, stainless steel housing, 10m cable DXX:LZX886 Flow throu unit for Nitratax clear sc Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Nitrate in Water, Nitratax plus sc, 0,1…50mg/l, 4-20mA Output, immersion Application example: Nitrate monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, UV absorption method, immersion, meas. range 0,1…50 mg/l NO2+3-N DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV417.99.20001 Nitratax plus sc, meas gap 2mm, meas range 0,1…50 mg/l NO2+3-N, UV

absorption, stainless steel housing, turbidity compensation, wiper cleaning, 10m cable

DXX:LZX414.00.10000 Mounting Assembly Kit "Rim Mounting", Stainless Steel, with 90° adapater for fixing of NITRATAX to a tank or channel

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x Relays, 24VdC power supply

Nitrate in Water, Nitratax sc, 0,1…20mg/l, 4-20mA Output, immersion Application example: Nitrate monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, UV absorption method, immersion, meas range 0,1…20 mg/l NO2+3-N, cost effective sensor, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV439.99.10001 Nitratax sc, meas gap 1mm, meas range 0,1…20 mg/l NO2+3-N, UV adsorbtion,

stainless steel housing, turbidity compensation, wiper cleaning, 10m cable DXX:LZX414.00.10000 Mounting Assembly Kit "Rim Mounting", Stainless Steel, with 90° adapater

for fixing of NITRATAX to a tank or channel

Page 22: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

22

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Nitrate in Water, Nitratax plus sc, 0,1…100mg/l, 4-20mA Output, immersion Application example: Nitrate monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, UV absorption method, immersion, meas range 0,1…100 mg/l NO2+3-N, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV417.99.10001 Nitratax plus sc, meas gap 1mm, meas range 0,1…100 mg/l NO2+3-N, UV

adsorbtion, stainless steel housing, turbidity compensation, wiper cleaning, 10m cable

DXX:LZX414.00.10000 Mounting Assembly Kit "Rim Mounting", Stainless Steel, with 90° adapater for fixing of NITRATAX to a tank or channel

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Nitrate in Water, NO3D sc, 4-20mA Output, immersion Application example: Nitrate monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, ISE method, cleaning system recommended, immersion, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV442.99.00001 NO3D sc, meas. range 0,5…1000 mg/l NO3-N, ISE method for Nitrate and

Chloride, pHD reference electrode, meas temp. 2..40°C, 10m cable DXX:LZX914.99.12400 Chain mount assembly for NO3D, PVC Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 23: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

23

1.9 Ammonia measurement in WWW applications

Ammonia in Water, NH4D, 0,2.. 1000mg/l, 4-20mA Output, immersion Application example: Ammonia monitoring inlet wwtp after primary clarifier, before aeration tank Comment: SC technology, ISE method, Potassium compensation, cleaning system recommended, for conc. > 1mg/l NH4-N, immersion, recommended configuration if fits to specifications DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX: LXV437.99.00001 NH4D sc, Ammonia-ISE sensor, meas. Range 0,2.. 1000mg/l NH4-N, 1.. 1000

mg/l K+, pHD reference electrode, integr. temperature sensor, with 10m sc cable DXX:LZX914.99.12400 Chain mount assembly for ISE sc, PVC Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Ammonia in Water, Amtax sc, 0,02.. 5mg/l, 4-20mA Output, immersion Application example: Ammonia monitoring outlet waste water treatment plant Comment: SC technology, GSE method (gas sensing electrode), Analyzer for outdoor installation, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV421.99.4100 Amtax sc, meas. range 0,02…5 mg/l NH4-N, gas sensing electrode method, in-

situ membrane filter probe with 5m heated tube, 230 VAC, Outdoor version, 10m cable

DXX:LZX414.00.50000 Rim Mount for filter probe for Amtax sc DXX:LZY316 Mount tank rim fixing for Analyzer and sc controller Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Ammonia in Water, Amtax sc, 0,5.. 20mg/l, 4-20mA Output, immersion Application example: Ammonia monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, GSE method (gas sensing electrode), Analyzer for outdoor installation, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply

Page 24: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

24

DXX:LXV421.99.1100 Amtax sc, meas. range 0,5…20 mg/l NH4-N, gas sensing electrode method, in-situ membrane filter probe with 5m heated tube, 230 VAC, Outdoor version, 10m cable

DXX:LZX414.00.50000 Rim Mount for filter probe for Amtax sc DXX:LZY316 Mount tank rim fixing for Analyzer and sc controller Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Ammonia in Water, Amtax sc, 1.. 100mg/l, 4-20mA Output, immersion Application example: Ammonia monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, GSE method (gas sensing electrode), , Analyzer for outdoor installation, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV421.99.2100 Amtax sc, meas. range 1…100 mg/l NH4-N, gas sensing electrode method, in-

situ membrane filter probe with 5m heated tube, 230 VAC, Outdoor version, 10m cable

DXX:LZX414.00.50000 Rim Mount for filter probe for Amtax sc DXX:LZY316 Mount tank rim fixing for Analyzer and sc controller Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Ammonia in Water, Amtax sc, 10.. 1000mg/l, 4-20mA Output, immersion Application example: Ammonia monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, GSE method (gas sensing electrode), Analyzer for outdoor installation, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV421.99.3100 Amtax sc, meas. range 10…1000 mg/l NH4-N, gas sensing electrode method,

in-situ membrane filter probe with 5m heated tube, 230 VAC, Outdoor version, 10m cable

DXX:LZX414.00.50000 Rim Mount for filter probe DXX:LZY316 Mount tank rim fixing for Amtax Analyzer and sc controller Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Ammonia in Water, Amtax Inter 2, 0,1.. 20mg/l, 4-20mA Output Application example: Ammonia monitoring at waste water treatment plant outlet Comment: ISO method for reporting purposes, Analyzer house needed, Fitrax sample filtration, filtrated sample need to be pumped to analyzer, immersion DXX: LPV397.52.01000 AMTAX Inter 2, Prozess-Ammonium Analyzer, meas. Range 1…80 mg/l NH4-N,

colorimetric Indophenol blue method, according DIN 38406 E5, 1x 0/4..20mA, 2 limit value contacts, IP54, 230 VAC

DXX:LXV294.52.02000 Filtrax, Fitration probe with 10m heated sample hose DXX:LZX414.00.40000 Tank fixing for Filtrax module

Page 25: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

25

DXX:LZX676 Mounting for control unit Option Profibus DP on request

Ammonia in Water, Amtax Inter 2, 1.. 80mg/l, 4-20mA Application example: Ammonia monitoring at waste water treatment plant outlet Comment: ISO method for reporting purposes, Analyzer house needed, filtrated sample need to be pumped to analyzer, immersion DXX: LPV397.52.11000 AMTAX Inter 2, Prozess-Ammonium Analyzer, meas. Range 1…80 mg/l NH4-N,

colorimetric Indophenol blue method, according DIN 38406 E5, 0/4..20mA, IP54, 230 VAC

DXX:LXV294.52.02000 Filtrax, Fitration probe with 10m heated sample hose DXX:LZX414.00.40000 Tank fixing for Filtrax module DXX:LZX676 Mounting for control unit Option Profibus DP on request

Page 26: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

26

1.10 Ammonia and Nitrate measurement in WWW applications

Ammonia and Nitrate in Water, AN ISE sc, 4-20mA Output, immersion Application example: Ammonia and Nitrate monitoring in waste water Aeration, Nitrification / Denitrification process Comment: SC technology, ISE method, Potassium and Chloride compensation, cleaning system recommended, immersion, recommended conc. NH4-N > 1mg/l DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV440.99.00001 AN ISE sc, meas. range 0,1…1000 mg/l NH4-N, 0,1... 1000 mg/l NO3-N, 0,1…

1000mg/l K+, 0,1.. 1000mg/l Cl-, ISE method for Ammonia and Nitrate, compensation for Potassium and Chloride, pHD reference electrode, meas temp. 2..40°C, 10m cable

DXX:LZX914.99.12400 Chain mount assembly for AN ISE sc, PVC Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 27: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

27

1.11 Phosphate measurement in WWW applications

Phosphate in Water, Phosphax sc, 0,05.. 15mg/l, 4-20mA Output, immersion Application example: waste water treatment plant, control of Phosphate removal process Comment: SC technology, colorimetric yellow method, Analyzer outdoor installation, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV422.99.1100 Phosphax sc, meas. range 0,05…15 mg/l PO4-P, colrimetric method, with filter

probe (5m heated tube), 230 VAC, Outdoor version, 10m cable DXX:LZX414.00.50000 Rim Mount for filter probe DXX:LZY316 Mount tank rim fixing for Amtax Analyzer and sc controller Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Phosphate in Water, Phosphax sc, 1.. 50mg/l, 4-20mA Output, immersion Application example: waste water treatment plant, control of Phosphate removal process Comment: SC technology, colorimetric yellow method, Analyzer outdoor installation, immersion DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV422.99.2100 Phosphax sc, meas. range 1…50 mg/l PO4-P, colrimetric method, with filter

probe (5m heated tube), 230 VAC, Outdoor version, 10m cable DXX:LZX414.00.50000 Rim Mount for filter probe DXX:LZY316 Mount tank rim fixing for Amtax Analyzer and sc controller Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Phosphate measurement, Phosphamate, 0.. 5mg/l, 1 channel, 4.. 20mA Application example: Drinking water, control addition of Phosphate Comment: ortho-Phosphate, panel version, for meas. Range > 5mg/l use Phosphamate with yellow method DXX:Z09211=A=3001 Phosphamat 9211, meas range 0…5 mg/l PO4, colorimetric molybdovanadate

blue method, 19” panel version, 1 channel, sample flow 15.. 20l/h, sample inlet 6 mm OD PE/PTFE tubing, sample temp 5.. 35°C, 1x 0/4.. 20mA, Relay, 100.. 240 VAC

Profibus DP version on request

Page 28: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

28

1.12 Sludge / Solid interface level measurement in WWW applications

Sludge / Solid interface in Water, Sonatax sc, 4-20mA Output, sc200 Application example: waste water treatment plant; Primary and secondary (final) settling tank, SBR reactor sludge pump control Comment: SC technology, Ultrasonic method, immersion, sc 200, replacement for Siemens DPS300 DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV431.99.00001 Sonatax sc, meas. range 0,2…12 m sludge level, ultrasonic measurement

principle, wiper cleaning, 10m cable DXX:LZX414.00.70000 Rim Mount for Sonatax sc Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Sludge / Solid interface in Water, Sonatax sc, 4-20mA Output, sc1000 Application example: waste water treatment plant; Primary and secondary (final) settling tank, SBR reactor sludge pump control Comment: SC technology, Ultrasonic method, immersion, sc 1000 shows sludge profile curve, replacement for Siemens DPS300 DXX:LXV402.99.00001 sc1000 Display module DXX:LXV400.99.2R321 sc1000 probe module for 4 sc sensors, 100…240 VAC, Relay card with 4

relays, 2 analog Output cards with 8 0/4..20mA Output DXX:LZY767 Pole Mounting Assembly Kit, for sc200, complete Kit, incl. Pole

1.8m, Socket, Weather guard and UV shield for outdoor installation DXX:LXV431.99.00001 Sonatax sc, meas. range 0,2…12 m sludge level, ultrasonic measurement

principle, wiper cleaning, 10m cable DXX:LZX414.00.70000 Rim Mount for Sonatax sc Option Profibus DP: DXX:LXV400.99.2E021 sc1000 probe module for 4 sc sensors, 100…240 VAC, Profibus DP

Page 29: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

29

1.13 Chlorine in WWW applications

Total Free chlorine, CL17, 4-20mA Output Application example: Drinking water treatment, Monitor Total free chlorine in water, distribitution Network, outlet of drinking water treatment plant (reporting purpose) Comment: colorimetric DPD method DXX:5440001 Cl17, Chlorine analyzer, colorimetric DPD method, meas. range 0,035.. 5mg/l,

Inlet ¼" OD, quick connect fitting, Pmax 5.2 bar, sample flow 200…500 ml/min, Temp 5…40°C, outflow ½" ID barbed hose fitting, 1x 0/4…20mA, 2x alarm contact relays

DXX:5448900 Power cord, 240 VAC, with European plug, 1.83m

Total Chlorine, Cl17, 4-20mA Output Application example: Drinking water treatment, Monitor total residual chlorine concentration Comment: colorimetric DPD method, Sum of all chlorine containing compounds incl. free chlorine and combined chlorine (chloroamines). DXX:5440002 Cl17, Chlorine analyzer, colorimetric DPD method, meas. range 0,035.. 5mg/l,

Inlet ¼" OD, quick connect fitting, Pmax 5.2 bar, sample flow 200…500 ml/min, Temp 5…40°C, outflow ½" ID barbed hose fitting, 1x 0/4…20mA, 2x alarm contact relays

DXX:5448900 Power cord, 240 VAC, with European plug, 1.83m

Free Chlorine HOCl, 9184sc, 4-20mA Output Application example: Drinking water treatment, monitor free chlorine in water distribitution network Comment: ampermoteric electrode method, measurement of free (active) Chlorine HOCl, gives real image of the biocide capacity of the active chlorine present in the water, direct reading of HOCl whatever pH and temperature are, no waste chemicals, for applications with permanent or interim chlorination of water DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV430.99.00001 9184sc, amperometric chlorine analyzer, electrode and flow cell mounted on

panel, meas. range 0…20mg/l, sample flow 200..250ml/min Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Total Free Chlorine, 9184sc, 4-20mA Output Application example: Drinking water treatment, monitor free chlorine in water distribitution network, outlet of drinking water treatment plant (reporting purpose) Comment: ampermoteric electrode method, measurement of free Chlorine total HOCl +OCl-, pH measurement, applicable in water samples with pH 4…8, for applications with permanent or interim chlorination of water DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply

Page 30: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

30

DXX:LXV430.99.00001 9184sc, amperometric chlorine analyzer, electrode and flow cell mounted on panel, integrated pH electrode, meas. range 0…20mg/l, sample flow 200..250ml/min

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Total free Chlorine, acidification, 9184sc, 4-20mA Output Application example: Drinking water treatment, monitor free chlorine in water distribitution network, outlet of drinking water treatment plant (reporting purpose) Comment: for water samples with changing pH value or pH >8, ampermoteric electrode method, measurement of total free Chlorine, HOCl +OCl-, pH electrode, for applications with permanent or interim chlorination of water DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV430.99.00001 9184sc, amperometric chlorine analyzer, electrode and flow cell mounted on

panel, integrated pH electrode, meas. range 0…20mg/l, sample flow 200..250ml/min

DXX:LZY051 9180 sc Acidification Unit, to adjust pH sample in the range 5.5 ... 6.5

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Free Chlorine, CL10F sc, 4-20mA Output Application example: Drinking water treatment, monitor free chlorine in water distribitution network Comment: ampermoteric electrode method, no waste chemicals, measurement of free Chlorine HOCl +OCl- , CL10 only for applications with permanent chlorination of water DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV45A.98.21022 CL10F sc, amperometric chlorine analyzer, electrode and flow cell mounted on

stainless steel panel, flow sensor, sc gateway and flow cell with threaded fitting ¼” inlet, 3/8” outlet, sample floe 30…50 l/h, meas. range 0..10 mg/l Cl2

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Free Chlorine, pHD, CL10F sc, 4-20mA Output Application example: Drinking water treatment, monitor free chlorine in water distribitution network Comment: ampermoteric electrode method, measurement of free Chlorine, no waste chemicals, measurement of free Chlorine HOCl +OCl- ,CL10 only for applications with permanent chlorination of water, pH measurement DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV45A.98.23022 CL10F sc, amperometric chlorine analyzer, electrodes and flow cell mounted on

stainless steel panel, flow sensor, sc gateway and flow cell with threaded fitting

Page 31: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

31

¼” inlet, 3/8” outlet, sample floe 30…50 l/h, meas. range 0..10 mg/l Cl2, integrated pHD pH Differential sensor with Pt1000 Temp. compensation

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Total Chlorine, pHD, CL10T sc, 4-20mA Output Application example: Drinking water treatment, monitor free chlorine in water distribitution network, outlet of drinking water treatment plant (reporting purpose) Comment: ampermoteric electrode method, applicable in water samples with pH 4…9, CL10 only for applications with permanent chlorination of water, Sum of all chlorine containing compounds incl. free chlorine and combined chlorine (chloroamines), pH measurement DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV45B.98.23022 CL10T sc, amperometric chlorine analyzer, electrodes and flow cell mounted on

stainless steel panel, flow sensor, sc gateway and flow cell with threaded fitting ¼” inlet, 3/8” outlet, sample floe 30…50 l/h, meas. range 0..10 mg/l Cl2, integrated pHD pH Differential sensor with Pt1000 Temp. compensation

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Total Chlorine, acidification, pHD, CL10T sc, 4-20mA Output Application example: Drinking water treatment, monitor free chlorine in water distribitution network, outlet of drinking water treatment plant (reporting purpose) Comment: for water samples with changing pH value or pH >8, ampermoteric electrode method, Sum of all chlorine containing compounds incl. free chlorine and combined chlorine (chloroamines). CL10 only for applications with permanent chlorination of water, pH measurement DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV45B.98.23022 CL10T sc, amperometric chlorine analyzer, electrodes and flow cell mounted on

stainless steel panel, flow sensor, sc gateway and flow cell with threaded fitting ¼” inlet, 3/8” outlet, sample floe 30…50 l/h, meas. range 0..10 mg/l Cl2, integrated pHD pH Differential sensor with Pt1000 Temp. compensation

DXX:LZY051 9180 sc Acidification Unit, to adjust pH sample in the range 5.5 ... 6.5 Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 32: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

32

1.14 Chlorine Dioxide and Ozone in WWW applications

Chlorine Dioxide, 9187sc, 4-20mA Output Application example: Drinking water treatment, outlet drinking water treatment plant Comment: ampermoteric electrode method, measurement of Chlorine Dioxide DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV434.99.00001 9187sc, amperometric chlorine dioxide analyzer, electrode and flow cell mounted

on panel, meas. range 0…2mg/l ClO2, sample flow 200..250ml/min

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Ozone, 9185sc, 4-20mA Output Application example: Drinking water treatment, control ozonization process in drinking water treatment plant Comment: ampermoteric electrode method, measurement of Ozone DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV433.99.00001 9185sc, amperometric chlorine dioxide analyzer, electrode and flow cell mounted

on panel, meas. range 0…2mg/l O3, sample flow 200..250ml/min

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 33: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

33

1.15 TOC measurement in WWW applications TOC measurement, Biotector B7000 Application example: inlet waste water treatment plant comment: carrier gas required, UV reactor with patented chemical 2 stage digestion, DIN38409, large tubings (d=3,2mm), measure large particles up to 2mm size, no need for sample preparation or filtering of sample, not influenced by high salt concentration up to 30% and calcium sludge, can measure solutions which contain oil, NDIR CO2 detector, large tubings (d=3,2mm), sample line cleaning, other meas. ranges available, option TN, TP, VOC with additional module possible, 1,3,4,5 and 6-channel version as option, Profibus available as option DXX:B4BFAA052BABAE1 TIC/TOC Version, meas. Range 0… 100 mg C/l normal expected

reading, UV reactor with patented chemical digestion, no extra Relays, language version English, 2 channel, 3x 4-20 mA output, sample temperature 2 … 60°C, pressure free sample, sample volume min. 14ml, sample flow 100ml/meas., Type 23 enclosure purge ready, dimensions 1250mm x 750mm x 320mm, IP44, ambient Temp. 5 … 40°C, Grab sample port and leak detector, 230V AC

Options for carrier gas: 1. Hach Lange Oxygen generator and concentrator 2. internal concentrator with air available on plant (free of hydrocarbons and

humidity) 3. oxygen gas available on the plant 4. Oxygen gas bottle

Page 34: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

34

2. Industrial Applications

2.1 pH measurement in industrial applications pH measurement, LZU5336T, 0/4-20mA, flow thru cell Application example: Process water in general, Raw water, water preparation (e.g. for boiler feed water), make up, reverse osmosis, demineralisation Comment: panel mount, flow throu, recommended configuration if fits to specifications

DXX:LXV2902.98.0002 si629p, panel mount 96x96 mm, 3 Relais, 1x 0/4-20mA Output, 230V AC power

supply DXX:LZU5336T.97.002 pH electrode for normal process conditions, diameter 12mm, length

120mm, PG13,5, MP4 plug, with temp. sensor DXX:LZU9301.99 Cable, length 5 m, with MP4 sensor plug, IP67 DXX:LZU6006.99 Flow thru cell, 2Sensors, flow detection, 6 bar, max. 45°C pH measurement, LZU5336T, 0/4-20mA, flow thru cell Application example: Process water in general, Raw water, water preparation (e.g. for boiler feed water), make up, reverse osmosis, demineralisation Comment: flow throu, recommended configuration if fits to specifications

DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5336T.97.002 pH electrode for normal process conditions, diameter 12mm, length

120mm, PG13,5, MP4 plug, with temp. sensor DXX:LZU9301.99 Cable, length 5 m, with MP4 sensor plug, IP67 DXX:LZU6006.99 Flow thru cell, 2Sensors, flow detection, 6 bar, max. 45°C pH measurement, LZU5336T, 0/4-20mA, HART, ATEX, flow thru cell Application example: Process water in general, Raw water, water preparation (e.g. for boiler feed water), make up, reverse osmosis, demineralisation comment: loop powered, HART, ATEX, flow throu

DXX:LXV500.99.70102 Si792P, pH/ORP transmitter, loop powered, HART, ATEX

II 2 (1)G Eex ib (ia) IIC T624VdC, 1x 0/4-20mA Output DXX:LZU5336T.97.002 pH electrode for normal process conditions, diameter 12mm, length

120mm, PG13,5, MP4 plug, with temp. sensor DXX:LZU9301.99 cable, length 5 m, with MP4 sensor plug, IP67 DXX:LZU6006.99 Flow thru cell, 2Sensors, flow detection, 6 bar, max. 45°C Option Profibus PA, ATEX DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6 pH measurement, LZY027, 4-20mA Output, bypass fitting SS 1.4401 Application example: Process water in general, Raw water, water preparation (e.g. for boiler feed water), make up, reverse osmosis, demineralisation comment: flow throu SS1.4401

Page 35: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

35

DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA Outputs, 4x Relays, 24VdC power supply

DXX:LZY027 pH combination electrode, with Pg 13.5 screw plug connector, integrated Pt1000 resistance thermometer, with polymer electrolyte, non-refillable, hole diaphragm, SMEK plug, Mounting length 120 mm

DXX:LZY021 Cable with SMEK connector, cable 5m DXX:LZY034 Flow fitting for bypass installation, mounting of electrode holder with

union nut, Viton gasket, Connection: thread G 3/4”, made of stainless steel (mat. No. 1.4401)

DXX: C74451A1789B2 Electrode holder for installation of 3 sensors, Pg 13.5; Made of stainless steel (mat. No. 1.4401) with stainless steel union nut

pH measurement, LZY027, 0/4-20 mA, HART, ATEX, bypass fitting SS 1.4401 Application example: Process water in general comment: loop powered, HART, ATEX, flow throu SS1.4401 DXX:LXV500.99.70102 Si792P, pH/ORP transmitter, loop powered, HART, ATEX

II 2 (1)G Eex ib (ia) IIC T624VdC, 1x 0/4-20mA Output DXX:LZY027 pH combination electrode, with Pg 13.5 screw plug connector, integrated

Pt1000 resistance thermometer, with polymer electrolyte, non-refillable, hole diaphragm, SMEK plug, Mounting length 120 mm

DXX:LZY021 Cable with SMEK connector, cable 5m DXX:LZY034 Flow fitting for bypass installation, mounting of electrode holder with

union nut, Viton gasket, Connection: thread G 3/4”, made of stainless steel (mat. No. 1.4401)

DXX: C74451A1789B2 Electrode holder for installation of 3 sensors, Pg 13.5; Made of stainless steel (mat. No. 1.4401) with stainless steel union nut

Option Profibus PA, ATEX DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6 pH measurement, LZU5334T, 0/4-20mA Output, Inline insertion fitting Application example: General industrial process water Comment: Inline insertion, pH electrode for high temp, high pressure DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5364.97.0002 pH electrode 5364, glass, L=120mm, D=12mm, PG13,5, for difficult media,

Tmax 130ºC, Pmax 6bar, open diaphragm, sterilizable, S8 connector DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZU7801.99 insertion/pipe mount fitting, retractable, stainless steel, type In78, max 130°C,

PG13,5, DN25 connection for weld in socket DXX:LZU6122.99 Weld-in-socket, SS, inclined 15º for fitting In 77 and In 78 pH measurement, PRO140, 4-20mA Output, HART, Inline retractable fitting Application example: Process water in industrial applications, high temperature, high pressure comment: loop powered, HART, pH electrode for high temp, high pressure, retractable fitting DXX:LXV500.99.70002 Si792P, pH/ORP transmitter, loop powered, HART, 24VdC, 1x 0/4-20mA

Output DXX:LZX546 PRO140PT100 pH combination electrode, integr. Pt100, pH electrode

for harsh conditions with high temperature and/or pressure applications;

Page 36: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

36

TOP68 screw plug; Ag/AgCl Reference, KCl/AgCl + KNO3-Gel electrolyte, double porous PTFE ring diaphragm, Tmax 135°C, Pmax 34bar (at 25°C), L 120mm, D 12mm

DXX:LZX548 Cable with TOP68 plug and PG13,5 connector, 5 m DXX:LZY236 Retractable fitting for inline installation and for mounting on vessels, made of

Stainless steel 1.4571, polyamide (PA) housing, Viton (FPM) gaskets, Pmax 4bar, Tmax 90°C, process connection thread G1 1/4”, for sensors with 120-mm shaft length, 12mm diameter and PG13,5 thread

DXX:LZY234 Welding-type connector, angled 15°, made of stainless steel (mat. No. 1.4571), connection G1 1/4”

Option HART, ATEX DXX:LXV500.99.70102 Si792P, pH/ORP transmitter, loop powered, HART, ATEX

II 2 (1)G Eex ib (ia) IIC T624VdC, 1x 0/4-20mA Output Option Profibus PA, ATEX: DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6 pH measurement, LZU5364, 4-20mA Output, HART, Inline retractable fitting Application example: Process water in industrial applications, high temperature, high pressure, CIP process, sterilizable with steam and autoclave, samples with oils, organic solvents, dyes, pigments, colour, fermentation, sugar industry comment: loop powered, HART, pH electrode for high temp, high pressure, retractable fitting with flushing connection and pneumatic drive DXX:LXV500.99.70002 Si792P, pH/ORP transmitter, loop powered, HART, 24VdC, 1x 0/4-20mA

Output DXX:LZU5364.97.0002 pH electrode 5364, glass, L=120mm, D=12mm, PG13,5, for difficult media,

Tmax 130ºC, Pmax 6bar, open diaphragm, sterilizable, S8 connector DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZY238 Retractable fitting for inline installation and for mounting on vessels, made of

Stainless steel 1.4571, polyamide (PA) housing, Viton (FPM) gaskets, Pmax 6bar, Tmax 90°C, process connection thread G1 1/4”, for sensors with 120-mm shaft length, 12mm diameter and PG13,5 thread, with 2 flush connections and pneumatic drive G 1/4" internal thread

DXX:LZY234 Welding-type connector, angled 15°, made of stainless steel (mat. No. 1.4571), connection G1 1/4”

Option HART, ATEX DXX:LXV500.99.70102 Si792P, pH/ORP transmitter, loop powered, HART, ATEX

II 2 (1)G Eex ib (ia) IIC T624VdC, 1x 0/4-20mA Output Option Profibus PA, ATEX: DXX:LXV500.99.76102 Si792P, pH/ORP transmitter, loop powered, Profibus PA, 24VdC, ATEX

II 2 (1)G Eex ib (ia) IIC T6 pH of pure water, LZY025, 4 relays Application example: Ultra pure water, electric power generation, industrial boiler feed water, steam circulation, pharmaceutical, microelectronics, chip production comment: dedicated traditional pH electrode for pure water, bypass installation DXX:LXV505.99.00002 Si794P, transmitter for pH, 20..253V AC/DC, 4 relays, 2x 0/4..20mA outputs LZY025 pH combination electrode, w/o thermometer, for critical media, boiler feedwater

and ultra-pure water with conductivities <100 μS/cm, Pg 13.5 screw plug connector, with liquid electrolyte, refillable, triple ceramic diaphragm, L=120 mm

DXX:C74450A184A1 KCl supply reservoir for connection to refillable combination electrodes or reference electrodes

Page 37: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

37

DXX:C74450A184D1 Hose, 2 m, to connect the KCl supply reservoir to the reference electrode/combination electrode

DXX:LZY029 Pt1000 resistance thermometer, all applications, with glass sheath, with Pg 13.5 screw plug connector

DXX:LZY037 Plug/cable combination, 5 m DXX:C74451A1789B2 Electrode holder for installation of 3 sensors, Pg 13.5; SS 1.4401, with stainless

steel union nut DXX:LZY032 Flow fitting for bypass installation, mounting of electrode holder with union nut,

Viton gasket (union nut not included in delivery), Connection: thread 3/8-18NPT; made of stainless steel (SS 1.4401)

Option HART DXX:LXV500.99.70002 Si792P, pH/ORP transmitter, loop powered, HART, 1x 0/4-20mA Output

pH of pure water, POLYMETRON 8362, no relays Application example: Ultra pure water, electric power generation, industrial boiler feed water, steam circulation, pharmaceutical, microelectronics, chip production comment: dedicated pH electrode with liquid filling solution DXX:Z09135=A=0000 Monec 9135 without relays DXX:Z08362=A=0000 8362 pH system, cable and flow throu cell, ideally suited for measurement in

demineralized water or power generation applications. Specially designed and tested for ultra pure water applications. Pt100 and 3 meters of cable included.

Option 4 relays: DXX:Z09135=A=0004 Monec 9135; 4 relays

pH of pure water, 8362 sc Application example: Ultra pure water, electric power generation, industrial boiler feed water, steam circulation, pharmaceutical, microelectronics, chip production comment: SC technology, dedicated sensor and flow fitting for pure water

DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x Relays, 24VdC power supply

DXX:6178002 8362 sc High Purity Water pH Panel incl. pH electrode, cable and flow throu chamber, designed for use in, and other applications that require excellent accuracy when measuring pH in ultrapure water. Self-Pressurizing Electrodes, Complete System

Cationic (acid) conductivity and pH of pure water, 9123, 4-20mA Application example: Power Plant, Differential Conductivity incl. cationic exchanger comment: complete system consist of transmitter, 2 conductivity probes, cation resin cartridge and manual flow valve, provides cationic (acid) conductivity and pH, calculation based on algorithm VGB 450 Le appendix, Design follows ASTM 6504 recommendations DXX:9123=A=1000 9123 pH calculated by differential conductivity acc. VGB 450 Le and ASTM 6504,

complete system, 9123 transmitter, 2 conductivity electrodes and resin cartridge, 2x 0/4.. 20mA outputs, 100…240 VAC

Option Profibus DP: DXX:9123=A=1012 9123 pH calculated by differential conductivity acc. VGB 450 Le and ASTM 6504,

complete system, 9123 transmitter, 2 conductivity electrodes and resin cartridge, 2x 0/4.. 20mA outputs, Profibus DP, 100…240 VAC

Page 38: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

38

pH calculation from differential conductivity, 9123 Panel, 4-20 mA Application example: Power Plant, Differential Conductivity inlet and outlet of cationic exchanger comment: pH caculator, 2x conductivity probes and flow fittings DXX: Z09123=A=0000 9123 pH calculator with differential conductivity Transmitter, 2x 0/4.. 20mA

outputs, 100…240 VAC 2 pcs of each: DXX:Z08310=A=0000 2EL sensor for Ultra-low Conductivity measurement, Cell constant 0.010 cm-

1, measuring range: 0.01 – 50 µS/cm, process adaptation ¾” NPT thread, installation length 57 mm, 16 mm Ø, electrode material: SS 316L and PES (Polyetherslufon), electrodes concentric, integrated Pt100, max. temp. 125°C, max. pressure 10 bar, protection Class IP 65

DXX: Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08318=A=0001 Flow-thru fiiting, SS 316L, sensor connection ¾” FNPT threat, process

connection ¼” FNPT threat, total length 165 mm, outer diameter 34 mm, material SS 316L, max. temperature 150°C, max. pressure 25 bar

Option Profibus DP: DXX: Z09123=A=0012 9123 pH calculator with differential conductivity Transmitter, Profibus DP,

100…240 VAC

pH measurement, LZU5364, 4-20mA, VARIVENT Application example: Beverage & Pharmaceutial application Comment: Dedicated glass electrode for beverages, sample flow need to be cut off to remove sensor from process, VARIVENT connector, CIP DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5364.97.0002 pH electrode 5364, glass, L=120mm, D=12mm, PG13,5, for difficult media,

Tmax 130ºC, Pmax 6bar, open diaphragm, sterilizable, S8 connector DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:33096 Varivent connection type Orbisphere, for PG13,5, L=120mm, d=12mm electrodes Option EN10204 3.1 certificate : CERT3.1/33096 EN10204 3.1 certificate for 33096 Varivent adapter

Page 39: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

39

2.2 ORP measurement in industrial applications

ORP Measurement, LZU5358, 0/4-20mA Output Application example: Process water in general Comment: Panel mount, cost effective, flow throu, electrode is not recommended for water with low conductivity, colloids, particles or suspensions DXX:LXV2702.98.0002 Si627P, panel mount 96x96 mm, 230VAC, 1x 0/4-20 mA output DXX: LZU5358.97.0002 ORP Elektrode 5358 with PG13,5 L 120mm, D 12mm, connector and fixed cable

5m, 0-80°C, Pmax 5bar, pH 0-14, for pool and drinking water, 1x ceramic diaphragm

DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZU6006.99 Flow thru cell, 2Sensors, flow detection, 6 bar, max. 45°C ORP measurement, LZU5353, 0/4-20mA, flow thru cell Application example: Process water in general Comment: flow throu, recommended configuration if fits to specifications

DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5353.97.0002 ORP electrode 5353, S8 connector, PG13,5, L 120mm, D 12mm, ceramic

diaphragm, reference electrode protected by internal ceramic diaphragm DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZU6006.99 Flow thru cell, 2Sensors, flow detection, 6 bar, max. 45°C

ORP Measurement, LZU5353, 4-20mA Output, Immersion Application example: Process Water Comment: SC technology, recommended configuration if fits to specifications DXX:LXV404.99.70101 sc200 controller, 1 input for conventional pH/ORP electrodes, 2x 0/4-20mA

Outputs, 4x Relays, 24VdC power supply DXX:LZU5353.97.0002 ORP electrode 5353, S8 connector, PG13,5, L 120mm, D 12mm, ceramic

diaphragm, reference electrode protected by internal ceramic diaphragm DXX:LZU1005.99 cable 5m, S8 connector, IP65 DXX:LZH066 Immersion hardware 1m, PP, atm. Pressure, Tmax 80°C DXX:LZH067 Electrode holder for LZH066, PP, for 3 PG13,5 electrodes, atm. Pressure, Tmax

80°C Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 40: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

40

2.3 Conductivity measurement in industrial applications Conductivity of pure water, flow fitting Application example: Ultra pure water, Conductivity (after anionic exchanger and mixed bed), electric power generation, industrial boiler, pharmaceutical, microelectronics comment: flow fitting, recommended configuration if fits to specifications DXX:LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:Z08310=A=0000 2EL sensor for Ultra-low Conductivity measurement, Cell constant 0.010 cm-

1, measuring range: 0.01 – 50 µS/cm, process adaptation ¾” NPT thread, installation length 57 mm, 16 mm Ø, electrode material: SS 316L and PES (Polyetherslufon), electrodes concentric, integrated Pt100, max. temp. 125°C, max. pressure 10 bar, protection Class IP 65

DXX: Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08318=A=0001 Flow-thru fiiting, SS 316L, sensor connection ¾” FNPT threat, process

connection ¼” FNPT threat, total length 165 mm, outer diameter 34 mm, material SS 316L, max. temperature 150°C, max. pressure 25 bar

Conductivity of pure water, HART, flow fitting Application example: Ultra pure water, electric power generation, industrial boiler, pharmaceutical, microelectronics comment: flow fitting DXX:LXV501.99.70002 Si792C, conductivity transmitter for contacting electrodes, loop powered, HART,

24 VDC power supply, 1 analog current output DXX:Z08310=A=0000 2EL sensor for Ultra-low Conductivity measurement, Cell constant 0.010 cm-

1, measuring range: 0.01 – 50 µS/cm, process adaptation ¾” NPT thread, installation length 57 mm, 16 mm Ø, electrode material: SS 316L and PES (Polyetherslufon), electrodes concentric, integrated Pt100, max. temp. 125°C, max. pressure 10 bar, protection Class IP 65

DXX:Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08318=A=0001 Flow-thru fiiting, SS 316L, sensor connection ¾” FNPT threat, process

connection ¼” FNPT threat, total length 165 mm, outer diameter 34 mm, material SS 316L, max. temperature 150°C, max. pressure 25 bar

Option: Profibus PA, ATEX DXX:LXV501.99.76102 Si792C, conductivity transmitter for contacting electrodes, loop powered,

Profibus PA, ATEX: II 2 (1)G Eex ib (ia) IIC T6, 24 VDC power supply, 1 analog current output

Conductivity of water, medium range, flow fitting Application example: process water, water treatment comment: flow fitting, recommended configuration if fits to specifications DXX:LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:Z08311=A=0000 2EL sensor for low Conductivity measurement, cell constant 0.10 cm-1,

measuring range 0.1 – 500 µS/cm, Process adaptation ¾” NPT thread, Installation length 57 mm, 16 mm Ø, electrode material SS 316L and PES

Page 41: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

41

(Polyetherslufon), electrodes concentric, integrated Pt100, max. temp 125°C, max. pressure 10 bar, protection Class IP 65

DXX:Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08318=A=0001 Flow-thru fiiting, SS 316L, sensor connection ¾” FNPT threat, process

connection ¼” FNPT threat, total length 165 mm, outer diameter 34 mm, material SS 316L, max. temperature 150°C, max. pressure 25 bar

Conductivity of water, medium range, flow fitting, HART Application example: process water, water treatment comment: flow fitting DXX:LXV501.99.70002 Si792C, conductivity transmitter for contacting electrodes, loop powered, HART,

24 VDC power supply, 1 analog current output DXX:Z08311=A=0000 2EL sensor for low Conductivity measurement, cell constant 0.10 cm-1,

measuring range 0.1 – 500 µS/cm, Process adaptation ¾” NPT thread, Installation length 57 mm, 16 mm Ø, electrode material SS 316L and PES (Polyetherslufon), electrodes concentric, integrated Pt100, max. temp 125°C, max. pressure 10 bar, protection Class IP 65

DXX:Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08318=A=0001 Flow-thru fiiting, SS 316L, sensor connection ¾” FNPT threat, process

connection ¼” FNPT threat, total length 165 mm, outer diameter 34 mm, material SS 316L, max. temperature 150°C, max. pressure 25 bar

Option: Profibus PA, ATEX DXX:LXV501.99.76102 Si792C, conductivity transmitter for contacting electrodes, loop powered,

Profibus PA, ATEX: II 2 (1)G Eex ib (ia) IIC T6, 24 VDC power supply, 1 analog current output

Conductivity of water, high range, flow fitting Application example: process water, water treatment comment: flow fitting DXX :LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:Z08312=A=0000 2EL sensor for medium range Conductivity measurement, cell constant 1.0

cm-1, measuring range 1 – 5 mS/cm, process adaptation: ¾” NPT thread, installation length 57 mm, 16 mm Ø, electrode material Graphit and PES (Polyetherslufon), electrodes planparallel, integrated Pt100, max. temp. 125°C, max. pressure 10 bar, protection Class IP 65

DXX:Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08318=A=0001 Flow-thru fiiting, SS 316L, sensor connection ¾” FNPT threat, process

connection ¼” FNPT threat, total length 165 mm, outer diameter 34 mm, material SS 316L, max. temperature 150°C, max. pressure 25 bar

Conductivity of water, high range, flow fitting, HART Application example: process water, water treatment comment: flow fitting DXX:LXV501.99.70002 Si792C, conductivity transmitter for contacting electrodes, loop powered, HART,

24 VDC power supply, 1 analog current output DXX:Z08312=A=0000 2EL sensor for medium range Conductivity measurement, cell constant 1.0

cm-1, measuring range 1 – 5 mS/cm, process adaptation: ¾” NPT thread, installation length 57 mm, 16 mm Ø, electrode material Graphit and PES

Page 42: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

42

(Polyetherslufon), electrodes planparallel, integrated Pt100, max. temp. 125°C, max. pressure 10 bar, protection Class IP 65

DXX:Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08318=A=0001 Flow-thru fiiting, SS 316L, sensor connection ¾” FNPT threat, process

connection ¼” FNPT threat, total length 165 mm, outer diameter 34 mm, material SS 316L, max. temperature 150°C, max. pressure 25 bar

Option: Profibus PA, ATEX DXX:LXV501.99.76102 Si792C, conductivity transmitter for contacting electrodes, loop powered,

Profibus PA, ATEX: II 2 (1)G Eex ib (ia) IIC T6, 24 VDC power supply, 1 analog current output

Conductivity measurement, weld on Application example: Process liquids Comment: Inductive conductivity sensor PP, weld on, recommended configuration if fits to specifications DXX :LXV507.99.00002 Si794I Transmitter for Inductive conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:3725E2T Inductive conductivity sensor made of PP with 6m cable, universal 3/4"NPT

thread, 6,9bar at 100°C, measuring range 0,1-2000mS/cm DXX:LZY043 Welding connector, SS 1.4301, with 1 gasket (Viton) DXX:LZY041 Union nut, DN 50, SS 1.4301 DXX:LZH122 Electrode holder DXX:LZX985 Adjustment set for inductive conductivity sensors (cable with definet resistance)

Conductivity measurement, flow fitting PP Application example: Process liquids Comment: Inductive conductivity sensor PP, flow fitting PP DXX :LXV507.99.00002 Si794I Transmitter for Inductive conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:3725E2T Inductive conductivity sensor made of PP with 6m cable, universal 3/4"NPT

thread, 6,9bar at 100°C, measuring range 0,1-2000mS/cm DXX:LZU215.99.1E220 Flow-thru fitting, PP connection 1/4" DXX:LZX985 Adjustment set for inductive conductivity sensors (cable with definet resistance)

Conductivity measurement, flow fitting PVDF Application example: corrosive media like acid, alkaline solutions Comment: Inductive conductivity sensor PVDF, flow fitting PVDF DXX :LXV507.99.00002 Si794I Transmitter for Inductive conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:3726E2T Inductive conductivity sensor made of PVDF with 6m cable, universal 3/4"NPT

thread, 6,9bar at 100°C, measuring range 0,1-2000mS/cm DXX:LZY039 Flow-thru fitting for bypass installation, Viton gasket, Connection: thread G 3/4”,

made of PVDF DXX:LZY041 Union nut, DN 50, SS 1.4301 DXX:LZH122 Electrode holder DXX:LZX985 Adjustment set for inductive conductivity sensors (cable with definet resistance)

Page 43: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

43

Conductivity measurement, PEEK, ATEX, HART, flow fitting Application example: corrosive media like acid, alkaline solutions, intrinsic safe areas Comment: Inductive conductivity sensor PEEK, flow fitting PVDF, ATEX, HART DXX:LXV503.99.70102 Si792I, conductivity transmitter for inductive 3700 series electrodes, loop

powered, HART, ATEX: II 2 (1)G Eex ib (ia) IIC T6, 24 VDC power supply, 1 analog current output

DXX:3727E2T Inductive conductivity sensor made of Peek with 6m cable, admitted for ATEX Zone 1, universal 3/4"NPT thread, 13,8bar at 200°C, measuring range 0,1-2000mS/cm

DXX:LZY039 Flow-thru fitting, PVDF, for bypass applications, connection R ¾ DXX:LZY041 Union nut, DN 50, SS 1.4301 DXX:LZH122 Electrode holder DXX:LZX985 Adjustment set for inductive conductivity sensors (cable with definet resistance)

Conductivity measurement, FEP, ATEX, HART, flow fitting Application example: corrosive media like acid, alkaline solutions, intrinsic safe areas Comment: Inductive conductivity sensor made of FEP, flow fitting made of PVDF, ATEX, HART DXX:LXV502.99.70102 Si792I, conductivity transmitter for inductive electrodes 2200 series, loop

powered, Profibus PA, ATEX: II 2 (1)G Eex ib (ia) IIC T6, 24 VDC power supply, 1 analog, current output

DXX:7MA22008EB Inductive Conductivity sensor, made of FEP (Perfluoroethylene-propylene), intrinsic safe EEx ia IIC T4, integr. Pt 100, 5m fixed cable, conical flange DN50, meas. range 0.1…..2500 mS/cm, Tmax 130°C

DXX:LZY039 Flow-thru fitting, PVDF, for bypass applications, connection R ¾ DXX:LZY041 Union nut, DN 50, SS 1.4301 DXX:LZY985 Adjustment set for inductive conductivity sensors (cable with defined resistance)

Conductivity measurement, FEP, for high concentrated acids Application example: measurement of diluted and concentrated acids as well as corrosive oxidizing acids Comment: bypass measurement, Inductive conductivity sensor FEP, flow fitting PVDF with 25% reinforced glass fibre, several concentration curves like NaOH, H2SO4, HNO3 stored in transmitter (no concentration curve for Oleum) DXX :LXV507.99.00002 Si794I Transmitter for Inductive conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:7MA22008BF Inductive Conductivity sensor, made of FEP (Perfluoroethylene-propylene),

integr. Pt 100, conical flange DN50, 5m fixed cable, meas. range 0.1…..2500 mS/cm, Tmax 130°C

DXX:7MA85008AB Flow fitting, PTFE/GF 25, for bypass applications, sensor mounting using flange, with gasket and lange screwed gland, sensor connection conical flange DN50, process connection DN25 4-hole flange, Viton gaskets, flow rate 0,1..0,5l/min, Tmax 120°C, Pmax 4 bar at 120°C, Pmax 6 bar at 20°C

DXX:C79451A3302B6 Thermometer protective tube made of PTFE DXX:LZY985 Adjustment set for inductive conductivity sensors (cable with defined resistance)

Conductivity measurement, PEEK, Varivent flow fitting Application example: Beverage applications

Page 44: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

44

Comment: Inductive conductivity sensor and varivent flow fitting, recommended configuration if fits to specifications DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:7MA2200-8CB Inductive Conductivity sensor, made of PEEK, integrated Pt 100, 5 m fixed cable, measuring range 0 ... 0,1 mS/cm to 0 ... 2500 mS/cm, with special flange matching the VARIVENT fittings,O-ring made of EPDM

DXX:7MA2200-8FA Adjustment set for inductive conductivity sensors DXX:7MA8500-8AD VARIVENT flow fitting (DN50) for mounting on pipes DN50, made of SS,

including Varivent seal, SS, Clamp ring, SS, Gasket, EDPM (2 pcs.) DXX:7MA8500-8AE VARIVENT sealing ring, SS 1.4404

Conductivity measurement, PEEK, DN50 (milk tube) flow fitting Application example: Beverage applications Comment: Inductive conductivity sensor and DN50 (milk tube) flow fitting DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

7MA2200-8DA Inductive Conductivity sensor, made of PEEK, integrated Pt 100, 5 m fixed cable, measuring range: 0 ... 0.1 mS/cm to 0 ... 2500 mS/cm, mounting using conical flange DN50

DXX:7MA2200-8FA Adjustment set for inductive conductivity sensors DXX:LZY040 Flow fitting, PP, side connection R 3/4, for bypass applications,

sensor mounting using union nut (union nut not included in delivery) DXX:LZY041 Union nut, DN 50, SS 1.4301 DXX:LZY042 Standard gasket, DN 50 for union nut, Viton (set of 5)

Conductivity measurement, PP, sanitary clamp 2”, weld on Application example: General applications Comment: sanitary clamp 2” Inductive conductivity sensor, weld on, recommended configuration if fits to specifications DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:3705E2T inductive conductivity sensor made PP with 6m cable, EPDM compound gasket, sanitary form clamp 2" flange, 6,9bar at 100°C, measuring range 0,1-2000mS/cm

DXX:Z08394=A=0510 SS welding connector (h=13mm) incl.clamp and EPDM compound gasket

Conductivity measurement, PP, sanitary clamp 2”, flow thru Application example: General applications Comment: sanitary clamp 2” Inductive conductivity sensor, flow thru DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

Page 45: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

45

DXX:3705E2T inductive conductivity sensor made PP with 6m cable, EPDM compound gasket, sanitary form 2" flange, 6,9bar at 100°C, measuring range 0,1-2000mS/cm

DXX:Z08398=A=8200 Flow-thru Kit, 2.0" Sanitary design acc. ISO2852, made of SS316L, Includes Flow-thru assembly, 2.0" Sanitary design, 2.0" heavy-duty clamp and EPDM compound gasket. For 3700 series sensors

Conductivity measurement, PP, sanitary clamp 2”,T-fitting Application example: General applications Comment: sanitary clamp 2” Inductive conductivity sensor and T-flow fitting DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:3705E2T inductive conductivity sensor made PP with 6m cable, EPDM compound gasket, sanitary form 2" flange, 6,9bar at 100°C, measuring range 0,1-2000mS/cm

DXX:MH018S8SZ 2" tee, SS 316, heavy duty clamp, special cap and EPDM compound gasket

Page 46: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

46

Conductivity measurement, PEEK, sanitary clamp 2”,weld on Application example: General applications, Food & Beverage applications Comment: sanitary clamp 2” Inductive conductivity sensor DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:Z08398=A=2000 Inductive conductivity sensor type 8398 made of PEEK, 2” Tri-Clamp connection, integrated Pt 100, meas. range 0....2000mS/cm, cell const K = 2.35 cm-1, Tmax 140°C, Pmax 18 bar

DXX:Z08394=A=0510 SS welding connector (h=13mm) incl. clamp and EPDM compound gasket

Conductivity measurement, PEEK, sanitary clamp 2”, flow throu Application example: General applications, Food & Beverage applications Comment: sanitary clamp 2” Inductive conductivity sensor DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:Z08398=A=2000 Inductive conductivity sensor type 8398 made of PEEK, 2” Tri-Clamp connection, integrated Pt 100, meas. range 0....2000mS/cm, cell const K = 2.35 cm-1, Tmax 140°C, Pmax 18 bar

DXX:Z08398=A=8200 Flow-thru Kit, 2" Sanitary design acc. ISO2852, made of SS316L, Includes Flow-thru assembly, 2.0" Sanitary design, 2.0" heavy-duty clamp and EPDM compound gasket

Conductivity measurement, PFA, sanitary clamp 2”, weld on Application example: Food & Beverage applications Comment: sanitary clamp 2” Inductive conductivity sensor, weld on, recommended configuration if fits to specifications DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:3708E2T inductive conductivity sensor made of PFA with 6m cable, EPDM compound gasket, sanitary form 2" flange, 13,8bar at 200°C, measuring range 0,1-2000mS/cm

DXX:Z08394=A=0510 SS welding connector (h=13mm) incl. clamp and EPDM compound gasket

Conductivity measurement, PFA, sanitary clamp 2”, flow thru Application example: Food & Beverage applications Comment: sanitary clamp 2” Inductive conductivity sensor, flow thru DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:3708E2T inductive conductivity sensor made of PFA with 6m cable, EPDM compound gasket, sanitary form 2" flange, 13,8bar at 200°C, measuring range 0,1-2000mS/cm

DXX:Z08398=A=8200 Flow-thru Kit, 2.0" Sanitary design acc. ISO2852, made of SS316L, Includes Flow-thru assembly, 2.0" Sanitary design, 2.0" heavy-duty clamp and EPDM compound gasket

Page 47: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

47

Conductivity measurement, PFA, sanitary clamp 2”,T-fitting Application example: Food & Beverage applications Comment: sanitary clamp 2” Inductive conductivity sensor and T-flow fitting DXX:LXV507.99.00002 Si794I Conductivity transmitter for inductive electrodes, variable

power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:3708E2T inductive conductivity sensor made of PFA with 6m cable, EPDM compound gasket, sanitary form 2" flange, 13,8bar at 200°C, measuring range 0,1-2000mS/cm

DXX:MH018S8SZ 2" tee, SS 316, heavy duty clamp, special cap and EPDM compound gasket

Conductivity measurement for pure water, sanitary clamp 2”, flow thru Application example: Beverage & Pharmaceutical applications, pure water with low conductivity Comment: Contacting sensor, sanitary clamp 2”,flow thru, material Certificate 3.1B available DXX :LXV506.99.00002 Si794C Transmitter for Contacting conductivity, variable power supply 20...253 V

AC/DC, 4 relais contacts, 2 0/4-20mA outputs, PID controller, 2 parameter sets DXX:Z08394=A=2011 8394 series conductivity sensor, cell constant K=0,01, meas. Range

0…20µS/cm, sensor material SS316L, (Ra < 0.4 μm) Pmax 10bar, Tmax 150°C DXX:Z08319=A=0005 Cable with sensor plug, for 2-EL sensors, 5 m length with plug and open end to Analyzer site; Protection class IP65 DXX:Z08398=A=8200 Flow-thru Kit, 2.0" Sanitary design acc. ISO2852, made of SS316L, Includes

Flow-thru assembly, 2.0" Sanitary design, 2.0" heavy-duty clamp and EPDM compound gasket

Page 48: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

48

2.4 Oxygen dissolved (DO) and Gas measurement in industrial applications Dissolved Oxygen measurement for industrial applications, Flow fitting Application example: Standard water samples Comment: flow fitting DXX:LXV508.99.00002 Si794D si794 Transmitter for dissolved oxygen measurement, variable power

supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:LZY072 OxyGold G Dissolved Oxygen sensor, Ø12 x 120 mm, Pg13.5, VP6 top connector (IP68), steam sterilizable, with integrated 22kOhm NTC thermistor, Measuring range: 2 μg/l ... 20 mg/l, up to 12 bar and 0 ... 130°C, suitable for ultra-pure water, non- or low-carbonated beverages and chemical industries. with 3.1B certificate, EXLabel: II 1/2G EEx IA II C T4/T5/T6, ATEX No: TUV 03 ATEX 7005X, PG13,5 Thread, Sealing material: EDPM, 120mm shaft length, 12mm diameter, made of SS, (1.4435)

DXX:LZY079 Connection cable with VP plug connector (VP6.0), 5m with open end to instrument, for OxyGOLD G and OxyFERM VP sensors

DXX:LZY080 Flow fitting, for DO sensor LZY072, LZY075, PG13,5 Thread, for sensors with 120mm shaft, length, 12mm diameter, made of SS (1.4435), suitable up to 16 bar, 130°C, process connection, 10 mm swagelock

Dissolved Oxygen measurement ppb level, Flow fitting Application example: ppb level DO measurement Comment: flow fitting DXX:LXV509.99.00002 Si794D tr si794 Transmitter for dissolved oxygen measurement, trace level,

variable power supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets,

DXX:LZY072 OxyGold G Dissolved Oxygen sensor, Ø12 x 120 mm, Pg13.5, VP6 top connector (IP68), steam sterilizable, with integrated 22kOhm NTC thermistor, Measuring range: 2 μg/l ... 20 mg/l, up to 12 bar and 0 ... 130°C, suitable for ultra-pure water, non- or low-carbonated beverages and chemical industries. with 3.1B certificate, EXLabel: II 1/2G EEx IA II C T4/T5/T6, ATEX No: TUV 03 ATEX 7005X, PG13,5 Thread, Sealing material: EDPM, 120mm shaft length, 12mm diameter, made of SS, (1.4435)

DXX:LZY079 Connection cable with VP plug connector (VP6.0), 5m with open end to instrument, for OxyGOLD G and OxyFERM VP sensors

DXX:LZY080 Flow fitting, for DO sensor LZY072, LZY075, PG13,5 Thread, for sensors with 120mm shaft, length, 12mm diameter, made of SS (1.4435), suitable up to 16 bar, 130°C, process connection, 10 mm swagelock

Dissolved Oxygen measurement for food&beverage, Flow fitting Application example: beverage applications Comment: flow fitting DXX:LXV508.99.00002 Si794D si794 Transmitter for dissolved oxygen measurement, variable power

supply 20...253 V AC/DC, 4 relais contacts, 2 analog current outputs, PID controller, 2 parameter sets

DXX:LZY075 OXYFERM VP Dissolved Oxygen sensor, with IP68 VP connector head, suitable for steam; sterilization, autoclavation and CIP, with integrated 22kOhm NTC thermistor, Measuring range: 10 μg/l ... 20 mg/l, up to 4 bar and 0 ... 130°C,

Page 49: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

49

suitable for beverage (low carbonated media) and chemical industries, with 3.1B certificate, EXLabel: II 1/2G EEx IA II C T4/T5/T6, PG13,5 Thread, Sealing material: EDPM, 120mm shaft length, 12mm diameter, made of SS (1.4435)

DXX:LZY079 Connection cable with VP plug connector (VP6.0), 5m with open end to instrument, for OxyGOLD G and OxyFERM VP sensors

DXX:LZY080 Flow fitting, for DO sensor LZY072, LZY075, PG13,5 Thread, for sensors with 120mm shaft, length, 12mm diameter, made of SS (1.4435), suitable up to 16 bar, 130°C, process connection, 10 mm swagelock

Oxygen Dissolved and Gas measurement, 28mm sensor, Varivent Application example: DO measurement in beverage applications, purity of CO2 (measure O2) Comment: M1100 Orbisphere LDO Oxygen measurement, 28mm sensor, Inline, wall mount, hygienic certificate EHEDG available, O-Rings conform to FDA, recommended configuration if fits to specifications DXX:410M/W1C00000 Orbisphere 410 controller, wall mount, 85…264 VAC, 3x 0/4-20mA, 3x relais,

RS485 DXX:33031 Power cord, EU plug DXX:M1100-S00 LDO sensor for inline applications, 0-2000ppb, det. limit 0,6 ppb, Tmeas 0..50 °C,

Tmax 0 .. 100°C, 28mm Orbisphere connection DXX:32510.03 Sensor cable, 3m DXX:33095 Varivent connection for 28mm sensor Option: Calibration Unit DXX:33088 Calibration device for M/K-type sensors Option EN10204 3.1 certificate : CERT3.1/M1100 EN10204 3.1 certificate for LDO M1100 sensors CERT3.1/33095 EN10204 3.1 certificate for 33095 Varivent connector

Oxygen Dissolved and Gas measurement, 12mm sensor, Varivent Application example: DO measurement in beverage applications, purity of CO2 (measure O2) Comment: M1100 Orbisphere LDO Oxygen measurement, 12mm sensor, Inline, Wall mount, hygienic certificate EHEDG available, O-Rings conform to FDA DXX:410M/W1C00000 Orbisphere 410 controller, wall mount, 85…264 VAC, 3x 0/4-20mA, 3x relais,

RS485 DXX:33031 Power cord, EU plug DXX:M1100-S10 LDO sensor for inline applications, 0-2000ppb, det. limit 0,6 ppb, Tmeas 0..50 °C,

Tmax 0 .. 100°C, PG13,5, diameter 12mm DXX:32510.03 Sensor cable, 3m DXX:33096 Varivent connection for 12mm sensor Option Calibration Unit : DXX:33088 Calibration device for M/K-type sensors Option EN10204 3.1 certificate : CERT3.1/M1100 EN10204 3.1 certificate for LDO M1100 sensors CERT3.1/33096 EN10204 3.1 certificate for 33096 Varivent adapter

Page 50: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

50

Dissolved Oxygen logger, Beverages Application example: Beverage applications Comment: Orbisphere Oxygen Logger, long stable spot (sensor), factory calibrated DXX:DGK3100-MB1060 Portable Orbisphere Oxygen Logger, LDO technology, measurement of Oxygen

dissolved and gas, meas. Range 1 ppb… 20ppm, resolution 0,001ppm, maintenance kit, swagelock 6mm connection, Inlet tube (Polyamide 4mm), Inlet filter

Oxygen Dissolved and Gas measurement for Fossil Power Plant, pre-mount panel Application example: Fossil Power Plant applications Comment: Orbisphere K1100 LDO Oxygen measurement, dry sensor, no electrolyte, no membrane change required, easy zero calibration with Nitrogen gas, 28mm sensor, Inline, pre-mount panel with wall mount controller, recommended configuration if fits to specifications DXX:DGKK1100-W1023 Kit to order K1100-S00 Sensor LDO technology, 0...2000ppb, det. limit 0,6ppb, Tmeas

0…50°C, Tmax 0..100°C, Orbisphere 28mm connection 410K/W1C00000 Orbisphere 410 controller, wall mount, 85..264 VAC, Pmax

16bar, 3x 0/4…20mA, 3x relais, RS485, 32510.03 Sensor cable, 3m DXX:DG33301 410/510 Pre-mount panel, mounting for wall transmitter 410/510, use with

Orbisphere 28mm sensors, flow chamber 32001.010, tubing, flow meter up to 500 ml/min, three way swagelock valve, dimension 300mm x 817mm

Option Calibration Unit: DXX:33088 Calibration device for M/K-type sensors Oxygen Dissolved and Gas measurement measurement for Nuclear Power Plant, wall mount Application example: Nuclear Power Plant applications Comment: Orbisphere LDO Oxygen measurement, dry sensor, no electrolyte, no membrane change required, easy zero calibration with Nitrogen gas, 28mm sensor, Inline, Wall mount, recommended configuration if fits to specifications DXX:410K/W1C00000 Orbisphere 410 controller, wall mount, 85…264 VAC, 3x 0/4-20mA, 3x relais,

RS485 DXX:33031 Power cord, EU plug DXX:K1200-S00 Nuclear LDO sensor for inline applications, 0-2000ppb, det. limit 0,6ppb, 28mm

Orbisphere connection DXX:32510.03 Sensor cable, 3m DXX:32001.030 Flow chamber “Delrin”, 6mm connection, O-ring EPDM Oxygen Dissolved and Gas measurement for Nuclear Power Plant, pre- Mounted panel Application example: Nuclear Power Plant applications Comment: Orbisphere LDO Oxygen measurement, dry sensor, no electrolyte, no membrane change needed, easy zero calibration with Nitrogen gas, 28mm sensor, Inline, pre-buildt panel with wall mount controller, recommended configuration if fits to specifications DXX:510K00/W1C10000 Orbisphere 510 controller, wall mount, 85…264 VAC, 3x 0/4-20mA, 3x relais,

RS485

Page 51: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

51

DXX:33031 Power cord, EU plug DXX:K1200-S00 Nuclear LDO sensor for inline applications, 0-2000ppb, det. limit 0,6ppb, 28mm

Orbisphere connection DXX:32510.10 Sensor cable, 10m DXX:DG33301 410/510 Pre-mount panel, mounting for wall transmitter 410/510, use with

Orbisphere 28mm sensors, flow chamber 32001.010, tubing, flow meter up to 500 ml/min, three way swagelock valve, dimension 300mm x 817mm

Option Calibration Unit: DXX:33088 Calibration device for M/K-type sensors Oxygen Dissolved and Gas measurement, Logger, Power Plant Application example: Power Plant applications Comment: Orbisphere Oxygen Logger, long stable spot (sensor), factory calibrated DXX:DGK3100-MI1060 Portable Orbisphere Oxygen Logger, LDO technology, measurement of

Oxygen dissolved and gas, meas. Range 1 ppb… 20ppm, maintenance kit, resolution 0,001ppm, swagelock 6mm connection, Inlet tube (Polyamide 4mm)

Dissolved Oxygen measurement for fermentation Process Application example: Fermentation processes in Food&Beverage and Pharmaceutical industry Comment: Orbisphere LDO Oxygen measurement, 12mm sensor, Inline, Wall mount, CIP processes possible (up to 135°C), lifetime of LDO spot depends on CIP conditions, M1100 is applicable to use in fermenters, factory calibrated, hygienic certificate EHEDG available DXX:410M/W1C00000 Orbisphere 410 controller, wall mount, 85…264 VAC, 3x 0/4-20mA, 3x relais,

RS485 DXX:33031 Power cord, EU plug DXX: M1100-S104 LDO sensor for Biotech applications 0-2000 ppb, 12mm PG-13.5 fitting,

Ra<0,4µm, Tmax 100°C DXX:32510.03 Sensor cable, 3m DXX:33096 Varivent connection for 12mm sensor Option Calibration Unit : DXX:33088 Calibration device for M/K-type sensors Option EN10204 3.1 certificate: CERT3.1/M1100 EN10204 3.1 certificate for LDO M1100 sensors CERT3.1/33096 EN10204 3.1 certificate for 33096 Varivent adapter

Page 52: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

52

2.5 Silica measurement in industrial applications DXX:Z09210=A=1001 Silica measurement in Pure water, 1 channel, Cabinet, 4-20mA Application example: Boiler feed water, desalination, semiconductor production Comment: Cabinet version, micro dosing pumps, no peristaltic pumps, no press. Air required DXX:Z09210=A=1101 Silikostat 9210, Panel version, 0/4..20mA, 1 channel, meas range 0...1000ppb,

reproducibility +/- 0,5 ppb, lowest det. limit < 0,5ppb, sample flow 5…30l/h, 100...240 V AC, 4 Relays

Silica measurement in Pure water, 1 channel, Panel, Profibus DP Application example: Boiler feed water, desalination, semiconductor production Comment: Panel version, micro dosing pumps, no peristaltic pumps, no press. Air required DXX:Z09210=A=1021 Silikostat 9210, Panel version, Profibus DP, 1 channel, meas range 0...1000ppb,

reproducibility +/- 0,5 ppb, lowest det. limit < 0,5ppb, sample flow 5…30l/h, 100...240 V AC, 4 Relays

Silica measurement in Pure water, 6 channel, Panel, Profibus DP Application example: Boiler feed water, desalination, semiconductor production Comment: Panel version, 2, 3, 4, 5 channel version also available, micro dosing pumps, no peristaltic pumps, no press. Air required DXX:Z09210=A=1026 Silikostat 9210, Panel version, Profibus DP, 6 channel, meas range 0...1000ppb,

reproducibility +/- 0,5 ppb, lowest det. limit < 0,5ppb, sample flow 5…30l/h, 100...240 V AC, 4 Relays

Silica measurement in Pure water, 1 channel, Wall, 4-20mA Application example: Boiler feed water, desalination, semiconductor production Comment: Wall mount version, micro dosing pumps, no peristaltic pumps, no press. Air required DXX:Z09210=A=1101 Silikostat 9210, wall mount version, 0/4..20mA, 1 channel, meas range

0...1000ppb, reproducibility +/- 0,5 ppb, lowest det. limit < 0,5ppb, sample flow 5…30l/h, 100...240 V AC, 4 Relays

Silica measurement in Pure water, 1 channel, Wall, Profibus DP Application example: Boiler feed water, desalination, semiconductor production Comment: Wall mount version, micro dosing pumps, no peristaltic pumps, no press. Air required DXX:Z09210=A=1121 Silikostat 9210, wall mount version, Profibus DP, 1 channel, meas range

0...1000ppb, reproducibility +/- 0,5 ppb, lowest det. limit < 0,5ppb, sample flow 5…30l/h, 100...240 V AC, 4 Relays

Page 53: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

53

Silica measurement in Pure water, 6 channel, Wall, Profibus DP Application example: Boiler feed water, desalination, semiconductor production Comment: Wall mount version, 2, 3, 4 or 5 channel version also available, micro dosing pumps, no peristaltic pumps, no press. Air required DXX:Z09210=A=1126 Silikostat 9210, wall mount version, Profibus DP, 6 channel, meas range

0...1000ppb, reproducibility +/- 0,5 ppb, lowest det. limit < 0,5ppb, sample flow 5…30l/h, 100...240 V AC, 4 Relays

Page 54: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

54

2.6 Sodium measurement in industrial applications Sodium measurement in Pure water, 1 channel, Panel, 4-20mA Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Panel version, ISE method, quick response because of frequent reactivation of electrode DXX:Z09245=A=0001 Sodimat 9245, Panel version, 0/4..20mA, 1 channel, meas range 0...10000 ppb,

reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Sodium measurement in Pure water, 4 channel, Panel, 4-20mA Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Panel version, 2 or 3 channel version also available, ISE method, quick response because of frequent reactivation of electrode DXX:Z09240=A=0004 Sodimat 9240, Panel version, 0/4..20mA, 4 channel, meas range 0...10000 ppb,

reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Sodium measurement in Pure water, 1 channel, Panel, Profibus DP Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Panel version, ISE method, quick response because of frequent reactivation of electrode DXX:Z09245=A=0021 Sodimat 9245, Panel version, Profibus DP, 1 channel, meas range 0...10000

ppb, reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Sodium measurement in Pure water, 4 channel, Panel, Profibus DP Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Panel version, 2 or 3 channel version also available, ISE method, quick response because of frequent reactivation of electrode DXX:Z09240=A=0014 Sodimat 9240, Panel version, RS485, 4 channel, meas range 0...10000 ppb,

reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

DXX:Z09125=A=1485 'Kit for Profibus DP with board for 91xx / 92xx and Operator Manual Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Page 55: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

55

Sodium measurement in Pure water, 1 channel, Wall, 4-20mA Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Wall mount version, ISE method, quick response because of frequent reactivation of electrode DXX:Z09245=A=0101 Sodimat 9245, Wall mount version, 0/4..20mA, 1 channel, meas range 0...10000

ppb, reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Sodium measurement in Pure water, 4 channel, Wall, 4-20mA Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Wall mount version, 2 or 3 channel version also available, ISE method, quick response because of frequent reactivation of electrode DXX:Z09240=A=0104 Sodimat 9240, Wall mount version, 0/4..20mA, 4 channel, meas range 0...10000

ppb, reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Sodium measurement in Pure water, 1 channel, Wall, Profibus DP Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Wall mount version, ISE method, quick response because of frequent reactivation of electrode DXX:Z09245=A=0121 Sodimat 9245, Wall mount version, Profibus DP, 1 channel, meas range

0...10000 ppb, reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Sodium measurement in Pure water, 4 channel, Wall, Profibus DP Application example: Boiler feed water, deionized water, condensate, semiconductor production Comment: Wall mount version, 2 or 3 channel version also available, ISE method, quick response because of frequent reactivation of electrode DXX:Z09240=A=0124 Sodimat 9240, Wall mount version, Profibus DP, 4 channel, meas range

0...10000 ppb, reproducibility < 0,02 ppb, low detection limit 0,01 ppb, sample flow around 5 l/h, sample pressure 0,2..6 bar, 100...240 V AC, 2 Relays

Option: kit K for Sodium measurement after cation exchanger DXX:Z09245=A=8315 Kit k

Page 56: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

56

2.7 Turbidity/ Solid measurement in industrial applications Turbidity measurement, SS7 sc Application example: Pulp & Paper (e.g. white & black liquor), Petrochemical, Food (e.g. samples containing starch, fat or oil), Boiler & Cooling Comment: Non-contacting technology, bypass, Tungsten lamp acc. USEPA180.1, ASTM D 6698; Standard Methods 2130B DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LPV431.99.0002 Surface Scatter SS7 sc, High range bypass turbidimeter, 0… 50°C, 0.1…9999.9

NTU, 2 m sc connection cable Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Turbidity measurement, SS7 sc/HST Application example: for hot and/or corrosive medias, temp up to 70°C, temporary 80°C Comment: Non-contacting technology, bypass, Tungsten lamp acc. USEPA180.1, ASTM D 6698; Standard Methods 2130B DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXXLPV432.99.0002 Surface Scatter SS7 sc/HST, High range bypass turbidimeter, 0… 70°C,

0.1…9999.9 NTU, 2 m sc connection cable Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option Sample cooler: 4855100 Heat exchanger unit / sample cooler for SS7 sc-HST, 316 SS, ¾” MNPT pipe

connection, pressure rating is 150 psi (10.5 bar). Turbidity / Solid measurement, TSS Vari sc, Varivent connection Application example: Food & Beverage applications, other industrial applications Comment: Inline, Varivent process connection, Tmax 80°C (short term 95°C, not steam sterilizable), no measurement according MEBAK DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV326.99.10001 TSS Vari sc, meas. range 0.001… 9999 FNU, Solids 0.001… 500 g/l, Pmax

16bar, Temp 0…80°C, sensor head SS Mat 1.4460, Sapphire glass, Gaskets FKM, cable length 10m

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option VARIVENT pipe for process Connection: DXX:LZU304.99.00010 DN65, VARIVENT pipe, made of SS 316L Mat. 1.4404, suitable for TSS VARI sc DXX:LZU304.99.00020 DN80, VARIVENT pipe, made of SS 316L Mat. 1.4404, suitable for TSS VARI sc

Page 57: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

57

DXX:LZU304.99.00030 DN100, VARIVENT pipe, made of SS 316L Mat. 1.4404, suitable for TSS VARI sc

DXX:LZU304.99.00040 DN125, VARIVENT pipe, made of SS 316L Mat. 1.4404, suitable for TSS VARI sc

Turbidity / Solid measurement, TSS XL sc, weld on Application example: Food&Beverage applications, other industrial applications Comment: Inline process connection, Tmax 80°C (short term 95°C) DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV327.99.10001 TSS XL sc, meas. range 0.001… 9999 FNU, Solids 0.001… 500 g/l, Pmax 16bar,

Temp 0…80°C, sensor head SS Mat 1.4460, Sapphire glass, Gaskets Silicone, cable length 10m

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option weld on connector: DXX:LZU302.99.10010 weld on connector, DN65, suitable for TSS XL sc DXX:LZU302.99.10020 weld on connector, DN80, suitable for TSS XL sc DXX:LZU302.99.10030 weld on connector, DN100, suitable for TSS XLI sc DXX:LZU302.99.10040 weld on connector, DN125, suitable for TSS XL sc Turbidity / Solid measurement, TSS sc TriClamp, weld on Application example: Measurement in intrinsic safe areas Comment: Inline, 2” Tri-Clamp connection, retractable ball valve fitting, weld on DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV327.99.20001 TSS sc TriClamp, meas. range 0.001… 9999 FNU, Solids 0.001… 500 g/l, 2”

Tri-Clamp connection, Pmax 16bar, Temp. 0…50 °C, sensor head SS Mat 1.4460, Sapphire glass, Silicone Gasket, cable length 10m

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option weld on connector: DXX:LZU302.99.00010 weld on connector, DN65, suitable for TSS sc TriClamp DXX:LZU302.99.00020 weld on connector, DN80, suitable for TSS sc TriClamp DXX:LZU302.99.00030 weld on connector, DN100, suitable for TSS sc TriClamp DXX:LZU302.99.00040 weld on connector, DN125, suitable for TSS sc TriClamp Turbidity / Solid measurement, TSS sc TriClamp, retractable ball valve Application example: Measurement in intrinsic safe areas Comment: Inline, 2” Tri-Clamp connection, retractable ball valve fitting, weld on DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply

Page 58: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

58

DXX:LXV327.99.20001 TSS sc TriClamp, meas. range 0.001… 9999 FNU, Solids 0.001… 500 g/l, 2” Tri-Clamp connection, Pmax 16bar, Temp. 0…50 °C, sensor head SS Mat 1.4460, Sapphire glass, Silicone Gasket, cable length 10m

DXX:LZU300.99.00000 Retractable ball valve fitting for TSS sc TriClamp sensor, incl. weld on connection, Pmax 6bar

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Turbidity / Solid measurement, TSS Ex1 sc, Clamp, ATEX Application example: Measurement in intrinsic safe areas Comment: Inline, 2” Tri-Clamp connection, ATEX Zone 1, EX II 2G Ex d IIC T6 Ta (–10 ... 50°C) DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV328.99.20001 TSS Ex1 sc, meas. range 0.001… 9999 FNU, Solids 0.001… 500 g/l, 2” Tri-

Clamp connection, Pmax 16bar, Temp. 0…50 °C, sensor head SS Mat 1.4460, Sapphire glass, Gaskets FKM, EX II 2G Ex d IIC T6 Ta (–10 ... 50°C), cable length 10m

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Option retractable ball valve process Connection: DXX:LZU301.99.00000 Retractable ball valve fitting for TSS EX1 sc TriClamp sensor, incl. weld on

connection, Pmax 6bar Turbidity / Solid measurement, TSS TITANIUM2 sc, Immersion Application example: titanium material for measurement of corrosive medias Comment: Immersion sensor, Tmax 60°C (short term 80°C) DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV329.99.10001 TSS TITANIUM2 sc Immersion, meas. range 0.001… 9999 FNU, Solids 0.001…

500 g/l, Pmax 10bar, Temp. 0…60 °C, Sapphire glass, cable length 10m Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply Turbidity / Solid measurement, TSS TITANIUM7 sc, Immersion Application example: titanium material for measurement of medias with high salt content Comment: Immersion sensor, Tmax 60°C (short term 80°C) DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV330.99.10001 TSS TITANIUM7 sc Immersion, meas. range 0.001… 9999 FNU, Solids 0.001…

500 g/l, Pmax 10bar, Temp. 0…60 °C, Sapphire glass, cable length 10m Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 59: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

59

Turbidity / Solid measurement, TSS TITANIUM2 sc, TriClamp Application example: titanium material for measurement of corrosive medias Comment: Inline, 2” Tri-Clamp connection, Tmax 60°C (short term 80°C) DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV329.99.20001 TSS TITANIUM2 sc TriClamp, meas. range 0.001… 9999 FNU, Solids 0.001…

500 g/l, 2” Tri-Clamp connection, Pmax 10bar, Temp. 0…60 °C, incl. silicone sealing, sensor metarial titanium grade 7, Sapphire glass, Silicone Gasket, cable length 10m

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Turbidity / Solid measurement, TSS TITANIUM7 sc, TriClamp Application example: titanium material for measurement of medias with high salt content Comment: Inline, 2” Tri-Clamp connection, Tmax 60°C (short term 80°C) DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV330.99.20001 TSS TITANIUM7 sc TriClamp, meas. range 0.001… 9999 FNU, Solids 0.001…

500 g/l, 2” Tri-Clamp connection, Pmax 10bar, Temp. 0…60 °C, incl. silicone sealing, sensor metarial titanium grade 7, Sapphire glass, Silicone Gasket, cable length 10m

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 60: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

60

2.8 Hydrazine / Oxygen Scavenger in industrial applications Hydrazine / Oxygen Scavenger measurement, 4..20 mA Application example: Industrial / boiler water, Power Plants Comment: measure oxygen scavengers, dissolved hydrazine, and carbohydrazide in water, panel version DXX:Z09186=A=0000 Hydrastat 9186, Amperometric, 3 electrode principle, 0...500 ppb dissolved

N2H4 or 0...100 ppb Carbohydrazide, mount on 19” panel, sample inlet connection Swageloc 4 x 6 mm tubing stainless steel, sample temp. 5...45°C, 2x 0/4..20mA, 4x Relays, 110.. 240 VAC

Option Profibus DP: DXX:Z09186=A=0012 Hydrastat 9186, Amperometric, 3 electrode principle, 0...500 ppb dissolved

N2H4 or 0...100 ppb Carbohydrazide, mount on 19” panel, sample inlet connection Swageloc 4 x 6 mm tubing stainless steel, sample temp. 5...45°C, 2x 0/4..20mA, Profibus DP, 110.. 240 VAC

Page 61: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

61

2.9 Phosphate in industrial applications Phosphate measurement, 0.. 5mg/l, 1 channel, 4.. 20mA Application example: Industrial / boiler water, cooling water, Power Plants, semiconductor industry Comment: ortho-Phosphate, panel version, 2 channel also available DXX:Z09211=A=3001 Phosphamat 9211, meas range 0…5 mg/l PO4, colorimetric molybdovanadate

blue method, 19” panel version, 1 channel, sample flow 15.. 20l/h, sample inlet 6 mm OD PE/PTFE tubing, sample temp 5.. 35°C, 1x 0/4.. 20mA, Relay, 100.. 240 VAC

Profibus DP version on request Phosphate measurement, 0.. 50 mg/l, 1 channel, 4.. 20mA Application example: Industrial / boiler water, Power Plants Application example: Industrial / boiler water, cooling water, Power Plants, semiconductor industry, 2 channel also available DXX:Z09211=A=4001 Phosphamat 9211, meas range 0…50 mg/l PO4, colorimetric yellow method, 19”

panel version, 1 channel, sample flow 15.. 20l/h, sample inlet 6 mm OD PE/PTFE tubing, sample temp. 5… 50°C, 1x 0/4.. 20mA, Relay, 100.. 240 VAC

Profibus DP version on request Phosphate measurement, 0.. 5mg/l, 4 channel, 4.. 20mA Application example: Industrial / boiler water, cooling water, Power Plants, semiconductor industry Comment: ortho-Phosphate, panel version, 1, 2 channel also available DXX:Z09211=A=3004 Phosphamat 9211, meas range 0…5 mg/l PO4, colorimetric molybdovanadate

blue method, 19” panel version, 4 channel, sample flow 15.. 20l/h, sample inlet 6 mm OD PE/PTFE tubing, sample temp 5.. 35°C, 4x 0/4.. 20mA, 4 Relays, 100.. 240 VAC

Profibus DP version on request Phosphate measurement, 0.. 50 mg/l, 4 channel, 4.. 20mA Application example: Industrial / boiler water, cooling water, Power Plants, semiconductor industry Comment: ortho-Phosphate, panel version, 1, 2 channel also available DXX:Z09211=A=4004 Phosphamat 9211, meas range 0…50 mg/l PO4, colorimetric yellow method, 19”

panel version, 4 channel, sample flow 15.. 20l/h, sample inlet 6 mm OD PE/PTFE tubing, sample temp. 5… 50°C, 4x 0/4.. 20mA, 4 Relays, 100.. 240 VAC

Profibus DP version on request

Page 62: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

62

2.10 Dissolved Ozone in industrial applications

Dissolved Ozone, 9185sc, 4-20mA Output Application example: Industrial water treatment, control ozonization process Comment: cost effective, ampermoteric electrode method, measurement of Ozone DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV433.99.00001 9185sc, amperometric chlorine dioxide analyzer, electrode and flow cell mounted

on panel, meas. range 0…2mg/l O3, sample flow 200..250ml/min

Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Dissolved Ozone, Orbisphere Application examples: Measurement for food, beverage and pharmaceutical industry , ozone production process 0-50ppm, residual Ozone measurement down to 0.4ppb, mineral water disinfection after filling before crowning, Pharmaceutical industry: Before and after UV lamp in pure water cycles for drug production. Comment:O-Rings FDA conform, additional material certificates available, measurement according ASTM D7677 including unique air calibration method, validation possible with Hach AccuVac Lab method, high accuracy of ±0.4 ppb or ±5%, whichever is greater DXX: 410C/W1C0000 Orbisphere 410 controller for ozone measurement, wall mount, 85…264 VAC, 3x

0/4-20mA, 3x relais, RS485 DXX:33031 Power cord, EU plug DXX:C1100-S00 Ozone sensor; Material Stainless Steel, guard ring platin; Viton O-ring; max.

pressure 40 bar DXX:32501.03 10 wire cable to connect electrochemical sensors to Orbisphere 410/510 wall and

panel instrument, length 3m DXX:32001.110 Flow chamber in stainless steel (316) with 6 mm fittings. Supplied with Viton O-

rings. DXX:2956A-C Recharge kit of 4 pre-filled cartridges with premounted 2956A membranes for

C1100 ozone sensors. Includes o-rings, cotton filters, cleaning tools and dacrons Options: DXX:C1100-T00 Ozone sensor; Material Titanium, guard ring platin; Viton O-ring; max. pressure

100 bar DXX:33095 Varivent connection for 28mm sensor CERT3.1/C1100 EN10204 3.1 certificate for ozone sensors C1100-xx CERT3.1/32001x EN10204 3.1 certificate for 32001.xxx flow chamber CERT3.1/33095 EN10204 3.1 certificate for 33095 Varivent adapter

Page 63: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

63

2.11 Hydrogen measurement in industrial applications

Hydrogen measurement, dissolved and Gas for Fossil Power Plant, wall Application example: Dissolved Hydrogen and Gas for Fossil Power Plant applications, corrosion control during startup of boiler and monitoring plant specific hydrogen level during standard mode, high accuracy down to 0,01 ppb Comment: Orbisphere electrochemical hydrogen sensor, 28mm sensor, online, Wall mount, recommended configuration if fits to specifications DXX:510B00/W1C0P000 Orbisphere 510 hydrogen (EC) inst, portable, 85-264 VAC, RS485 DXX:31230.01 EC Sensor, Substance measured: Hydrogen, Sensing head material: Stainless

Steel, Guard ring: Platinum, Maximum pressure: 100 bar, O-Ring: Viton DXX:32001.010 Flow chamber in stainless steel (316) with 6 mm fittings , Supplied with Viton O-

rings. DXX:32725 Kit for hydrogen electrochemical sensors. Includes membranes 2956A, electrolyte

29010, chloridizing solution 29011, mask 29026A, membrane holding ring 29229, and tools for sensor maintenance.

DXX:29046.0 Kit for protection cap DXX:32301.B Electrochemical sensor cleaning and regeneration unit, for 230 VAC. DXX:DF13311 Regulation valve type WHITEY DXX:DF13116 Swagelok connector between valve and flow chamber Hydrogen measurement, dissolved and Gas for Nuclear Power Plant, wall Application example: Dissolved Hydrogen and Gas for Nuclear Power Plant applications, monitoring reactor coolant above 1 ppb Comment: Orbisphere thermal conductivity hydrogen sensor, 28mm sensor, online, Wall mount, Nitrogen purge gas necessary, recommended configuration if fits to specifications DXX: 511F00/W1C0P000 Orbisphere 511, H2 (TC) , wall mount, 85-264 VAC, 3x 0/4-20 mA analog

outputs by channel, RS485, with ext. pressure output DXX:32505.05 5 meters sensor cable DXX:32605 Purge Backup Unit for TCD sensors. DXX:31250H TC Sensor, Substance measured: Hydrogen, Purge gas: Nitrogen, Protection cap

provided, Sensor Cable to be ordered: 32505.03, Maximum pressure: 20 bar. DXX:2952A Tefzel membranes, (32 mm diameter), 25 µm. Box of 25. DXX:32001.010 Flow chamber stainless steel (316) with 6 mm fittings, with EPDM O-rings DXX:32739 Maintenance Kit, Incl. membranes 29561A & 29562A, membrane holding ring

29229.01, kit 29082 and tools for sensor maintenance. Hydrogen measurement, dissolved and Gas for Fossil Power Plant, pre- mount panel Application example: Dissolved Hydrogen and Gas for Fossil Power Plant applications, corrosion control during startup of boiler and monitoring plant specific hydrogen level during standard mode, high accuracy down to 0,01 ppb Comment: Orbisphere electrochemical hydrogen sensor, 28mm sensor, online, 510 Wall mount controler, pre-mount panel, recommended configuration if fits to specifications DXX:510B00/W1C0P000 Orbisphere 510 hydrogen (EC) inst, portable, 85-264 VAC, RS485 DXX:31230.01 EC Sensor, Substance measured: Hydrogen, Sensing head material: Stainless

Steel, Guard ring: Platinum, Maximum pressure: 100 bar, O-Ring: Viton

Page 64: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

64

DXX:32001.010 Flow chamber in stainless steel (316) with 6 mm fittings , Supplied with Viton O-rings.

DXX:32725 Kit for hydrogen electrochemical sensors. Includes membranes 2956A, electrolyte 29010, chloridizing solution 29011, mask 29026A, membrane holding ring 29229, and tools for sensor maintenance.

DXX:29046.0 Kit for protection cap DXX:32301.B Electrochemical sensor cleaning and regeneration unit, for 230 VAC. DXX:DG33301 410/510 Pre-mount panel, mounting for wall transmitter 410/510, use with

Orbisphere 28mm sensors, flow chamber 32001.010, tubing, flow meter up to 500 ml/min, three way swagelock valve, dimension 300mm x 817mm

Dissolved Hydrogen, dissolved and Gas for Nuclear Power Plant, pre-mount panel Application example: Dissolved Hydrogen and Gas for Nuclear Power Plant applications, monitoring reactor coolant above 1 ppb Comment: Orbisphere thermal conductivity hydrogen sensor, 28mm sensor, online, 510 Wall mount controller, pre-mount panel, Nitrogen purge gas necessary, recommended configuration if fits to specifications DXX: 511F00/W1C0P000 Orbisphere 511, H2 (TC) , wall mount, 85-264 VAC, 3x 0/4-20 mA analog

outputs by channel, RS485, with ext. pressure output DXX:32505.05 5 meters sensor cable DXX:32605 Purge Backup Unit for TCD sensors. DXX:31250H TC Sensor, Substance measured: Hydrogen, Purge gas: Nitrogen, Protection cap

provided, Sensor Cable to be ordered: 32505.03, Maximum pressure: 20 bar. DXX:2952A Tefzel membranes, (32 mm diameter), 25 µm. Box of 25. DXX:DG33301 410/510 Pre-mount panel, mounting for wall transmitter 410/510, use with

Orbisphere 28mm sensors, flow chamber 32001.010, tubing, flow meter up to 500 ml/min, three way swagelock valve, dimension 300mm x 817mm

Page 65: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

65

2.12 Dissolved Carbon Dioxide measurement in industrial applications

Dissolved Carbon Dioxide measurement for beverages, inline, weld on Application example: brewery applications, beer production at filter, filler or CO2 dosing comment: Orbisphere thermal conductivity carbon dioxide sensor, 28mm sensor, weld on, Wall mount, not recommended for softdrink or mineral water application, Nitrogen or dry and oil free air purge gas necessary, recommended configuration if fits to specifications DXX:510D00/W1C0P000 Orbisphere 510 CO2 (TC) instrument, wall mount, 85-264 VAC, 0/4-20mA

analog output, RS485

DXX:31460 TC sensor, Substance measured: Carbon dioxide, Purge gas: Nitrogen, Protection cap provided, Sensor Cable to be ordered : 32505.03, with external temperature adapter, Maximum pressure : 20 bar, External Temperature sensor to be ordered : 32557/32559.

DXX:32517.00 LEMO 10 adapter to connect 32505 type sensor cable to 410 or 510 wall and panel instruments, length 40 cm

DXX:32605 Purge Backup Unit for TCD sensors. DXX:32505.10 10 meters sensor cable DXX:32557 External temperature sensor for in-line use, with 4 pin LEMO connector for TCD

sensors equipped with sensor adapter 32558 DXX:32003 Sensor insertion and retraction valve for use with Tuchenhagen adapter. DXX:29501.0 x2 Stainless steel sensor socket with EPDM O-rings, for welding to stainless steel

pipe DXX:32749 Maintenance Kit for CO2 & N2 sensors having the 29108 protection cap. Incl.

membranes 29561A, membrane holding ring 29228, kit 29082 for protection cap, and tools for sensor maintenance.

DXX:29089S6 Pressure Regulator Kit. Includes: 28511, 28512, 2 x 28091S6, and 32809.03. Dissolved Carbon Dioxide measurement for beverages, inline, VARIVENT Application example: brewery applications, beer production at filter, filler or CO2 dosing comment: Orbisphere thermal conductivity carbon dioxide sensor, 28mm sensor, Varivent fitting, Wall mount, not recommended for softdrink or mineral water application, Nitrogen or dry and oil free air purge gas necessary, recommended configuration if fits to specifications DXX:510D00/W1C0P000 Orbisphere 510 CO2 (TC) instrument, wall mount, 85-264 VAC, 0/4-20mA

analog output, RS485

DXX:31460 TC sensor, Substance measured: Carbon dioxide, Purge gas: Nitrogen, Protection cap provided, Sensor Cable to be ordered : 32505.03, with external temperature adapter, Maximum pressure : 20 bar, External Temperature sensor to be ordered : 32557/32559.

DXX:32517.00 LEMO 10 adapter to connect 32505 type sensor cable to 410 or 510 wall and panel instruments, length 40 cm

DXX:32605 Purge Backup Unit for TCD sensors. DXX:32505.10 10 meters sensor cable DXX:32557 External temperature sensor for in-line use, with 4 pin LEMO connector for TCD

sensors equipped with sensor adapter 32558 DXX:32003 Sensor insertion and retraction valve for use with Tuchenhagen adapter. DXX:33095 2x Varivent connection for 28mm sensor

Page 66: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

66

DXX:32749 Maintenance Kit for CO2 & N2 sensors having the 29108 protection cap. Incl. membranes 29561A, membrane holding ring 29228, kit 29082 for protection cap, and tools for sensor maintenance.

DXX:29089S6 Pressure Regulator Kit. Includes: 28511, 28512, 2 x 28091S6, and 32809.03.

Page 67: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

67

2.13 Dissolved Nitrogen measurement in industrial applications Dissolved Nitrogen measurement for beverages, inline, weld on Application example: brewery applications, beer production at filter, filler or N2 dosing comment: Orbisphere thermal conductivity nitrogen sensor, 28mm sensor, weld on, Wall mount, not recommended for softdrink or mineral water application, Carbon dioxide purge gas necessary, recommended configuration if fits to specifications DXX:511E00/W1C0P000 Orbisphere 511 N2 (TC) instrument, wall mount, 85-264 VAC, 0/4-20mA

analog output, RS485 DXX:31560 TC Sensor, Substance measured: Nitrogen, Purge gas: Carbon dioxide,

Protection cap provided, Sensor Cable to be ordered: 32505.03, with external temperature adapter, Maximum pressure: 20 bar, External Temperature sensor to be ordered: 32557/32559.

DXX:32517.00 LEMO 10 adapter to connect 32505 type sensor cable to 410 or 510 wall and panel instruments, length 40 cm

DXX:32605 Purge Backup Unit for TCD sensors. DXX:32505.10 10 meters sensor cable DXX:32557 External temperature sensor for in-line use, supplied with 4 pin LEMO connector

for TCD sensors equipped with sensor adapter 32558. Sensor socket must be ordered separately.

DXX:32003 Sensor insertion and retraction valve for use with Tuchenhagen adapter. DXX:29501.0 x2 Stainless steel sensor socket with EPDM O-rings for welding to stainless steel

pipe. DXX:32749 Maintenance Kit for CO2 & N2 sensors having the 29108 protection cap. Includes

membranes 29561A, membrane holding ring 29228, kit 29082 for protection cap, and tools for sensor maintenance.

DXX:29089S6 Pressure Regulator Kit. Incl: 28511, 28512, 2 x 28091S6, and 32809.03. Dissolved Nitrogen measurement for beverages, inline, VARIVENT Application example: brewery applications, beer production at filter, filler or N2 dosing comment: Orbisphere thermal conductivity nitrogen sensor, 28mm sensor, VARIVENT, Wall mount, not recommended for softdrink or mineral water application, Carbon dioxide purge gas necessary, recommended configuration if fits to specifications DXX:511E00/W1C0P000 Orbisphere 511 N2 (TC) instrument, wall mount, 85-264 VAC, 0/4-20mA

analog output, RS485 DXX:31560 TC Sensor, Substance measured: Nitrogen, Purge gas: Carbon dioxide,

Protection cap provided, Sensor Cable to be ordered: 32505.03, with external temperature adapter, Maximum pressure: 20 bar, External Temperature sensor to be ordered: 32557/32559.

DXX:32517.00 LEMO 10 adapter to connect 32505 type sensor cable to 410 or 510 wall and panel instruments, length 40 cm

DXX:32605 Purge Backup Unit for TCD sensors. DXX:32505.10 10 meters sensor cable DXX:32557 External temperature sensor for in-line use, supplied with 4 pin LEMO connector

for TCD sensors equipped with sensor adapter 32558. Sensor socket must be ordered separately.

DXX:32003 Sensor insertion and retraction valve for use with Tuchenhagen adapter. DXX:33095 2x Varivent connection for 28mm sensor

Page 68: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

68

DXX:32749 Maintenance Kit for CO2 & N2 sensors having the 29108 protection cap. Includes membranes 29561A, membrane holding ring 29228, kit 29082 for protection cap, and tools for sensor maintenance.

DXX:29089S6 Pressure Regulator Kit. Incl: 28511, 28512, 2 x 28091S6, and 32809.03.

Page 69: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

69

2.14 Oil in Water in industrial applications

Oil in Water, 4-20mA Output, 50/500ppb, Immersion Application example: general detection of oil contamination of water, detect oil contamination on rain water channels of industrial facilities or petrochemical plants Comment: SC technology, UV flurometric measurement, ppb level sensitivity, not influenced by particles, detects dissolved and emulgated oil DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV441.99.11101 FP 360sc fluerescence sensor for Oil/PAK, meas range 0…50/500 ppb (PAK

calibation standard), stainless steel housing, 10m cable DXX:LZX914.99.11110 Chain mount, stainless steel, for rail or tank rim fixing Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Oil in Water, 4-20mA Output, 500/5000ppb, Immersion Application example: Detection of contamination of water, detect oil contamination on rain water channels of industrial facilities or petrochemical plants Comment: SC technology, UV flurometric measurement, ppb level sensitivity, not influenced by particles, detects dissolved and emulgated oil DXX:LXV404.99.70501 sc200 controller, 1 input for sc sensor, 2x 0/4-20mA outputs, 4x

Relays, 24VdC power supply DXX:LXV441.99.21101 FP 360sc fluerescence sensor for Oil/PAK, meas range 0…500/5000 ppb

(PAK calibation standard), stainless steel housing, 10m cable DXX:LZX914.99.11110 Chain mount, stainless steel, for rail or tank rim fixing Option Profibus DP: DXX:LXV404.99.73501 sc200 controller, 1 input for sc sensor, Profibus DP, 2x 0/4-20mA Outputs, 4x

Relays, 24VdC power supply

Page 70: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

70

2.15 TOC measurement in industrial applications TOC measurement, Astro TOC Application example: Power Plant, boiler water Comment: DIN 38409, carrier gas (clean) at 2,8bar (no humidity, hydrcarbons and CO2) DXX:Z4195-1005 TOC 1950 PLUS, CRS, meas. Range 0,005 .. 5 mg/L, 2UV, TURBO, UV

digestion with chemicals, sample inlet 20 .. 200ml/min, sample pressure 0,15 … 6 bar, sample temperature 2 …70°C, 2x 4..20 mA, RS232, 5 alarm relays, dimensions 610 x 981 x 220 mm, ambient temperature 5 .. 40°C, IP55, 230 V AC, 50 – 60 Hz

DXX:Z4P95-2301-00 Accessories for AstroTOC 1950plus stainless steel enclosure, 230V, door with window and level measurement of reagents

DXX:LZY585 Carrier gas preparation unit 230V TOC measurement, Biotector B7000 Application example: general industrial water applications, polluted air port water (deizing) , Pulp & Paper industry, Shugar industry, Milk industry, Sewer monitoring stations comment: carrier gas required, UV reactor with patented chemical 2 stage digestion, DIN38409, large tubings (d=3,2mm), measure large particles up to 2mm size, no need for sample preparation or filtering of sample, not influenced by high salt concentration up to 30% and calcium sludge, can measure solutions which contain oil, NDIR CO2 detector, large tubings (d=3,2mm), sample line cleaning, other meas. ranges available, option TN, TP, VOC with additional module possible, 1,3,4,5 and 6-channel version as option, Profibus available as option DXX:B4BFAA052BABAE1 TIC/TOC Version, meas. Range 0… 100 mg C/l normal expected

reading, UV reactor with patented chemical digestion, no extra Relays, language version English, 2 channel, 3x 4-20 mA output, sample temperature 2 … 60°C, pressure free sample, sample volume min. 14ml, sample flow 100ml/meas., Type 23 enclosure purge ready, dimensions 1250mm x 750mm x 320mm, IP44, ambient Temp. 5 … 40°C, Grab sample port and leak detector, 230V AC

Options for carrier gas: 1. Hach Lange Oxygen generator and concentrator 2. internal concentrator with air available on plant (free of hydrocarbons and

humidity) 3. oxygen gas available on the plant 4. Oxygen gas bottle

TOC measurement, Biotector B7000, ATEX Application example: general industrial water applications, Chemical industry, Refineries, Petrochemical industry comment: carrier gas required, cert. by TUEV EExp ATEX Ex II 3G Ex pz T4, UV reactor with patented chemical digestion, measure large particles up to 2mm size, no need for filtering of sample, not influenced by high salt concentration up to 30% and calcium sludge, can measure solutions which contain oil, sample line cleaning, other meas. ranges available, option TN, TP, VOC with additional module possible, 1,3,4,5 and 6-channel version as option, Profibus available as option DXX:B4BFAA052BABAE1 TIC/TOC Version, meas. Range 0… 100 mg C/l normal expected reading, UV reactor with patented chemical digestion, no extra Relays, language

version English, 2 channel, 3x 4-20 mA output, sample temperature 2 … 60°C, pressure free sample, sample volume min. 14ml, sample flow 100ml/meas., Type

Page 71: Liquid Analytics Standard Configurations 2 1

Vers. 2.1 15.02.2012

71

34 enclosure, cert. by TUEV EExp ATEX Ex II 3G Ex pz T4, with integr. Oxygen concentrator, dimensions 1750mm x 750mm x 320mm, IP44, ambient Temp. 5 … 40°C, Grab sample port and leak detector, 230V AC

Options for carrier gas: 1. Hach Lange Oxygen generator and concentrator 2. internal concentrator with air available on plant (free of hydrocarbons and

humidity) 3. oxygen gas available on the plant 4. Oxygen gas bottle