Link Selection and OAM
Version 01
Stephen Haddock
July 18, 2012
1
![Page 2: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/2.jpg)
Example Scenario
2
Server
Client
Co-Location Facility
Data CenterNetwork
CarrierNetwork
• Client connects to a Server in a Co-Location facility
• A single VLAN is used to carry this service within the Data Center Network• All frames transmitted and received by Server are untagged.
• VLAN is monitored using CFM with Up MEPs at each interface to the Data Center Network.
![Page 3: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/3.jpg)
Server connects with Link Aggregation
3
• Server connects using Link Aggregation• 5-tuple hash used to distribute frames among LAG links.
• Up MEP sits above Link Aggregation• In practice, separation of the physical ports of the LAG may complicate
implementation of the MEP, forcing it to be either distributed between the ports or centralized but not resident on a single physical port.
Server
MAC Relay
VLAN (6.9)
Link Agg
MACMAC
Server
Link Agg
MACMAC
![Page 4: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/4.jpg)
Server connects with DRNI
4
Distributed Relay (EmulatedSystem C)
VLAN (6.9)
Link Agg
MACMAC
Server
Link Agg
MACMAC
MACMAC
(6.9) (6.9)
Server
B
A
MAC
(6.9)
Relay (B)
MAC
(6.9)
Relay (A)
Gateway Links (virtual)
• Server connects to two physically separate nodes (Systems A and B)
• The logical view, as seen from the point of view of the Server and the Data Center Network, is that there the Server connects to a third node (Emulated System C) through a single logical port.
![Page 5: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/5.jpg)
Distributed Relay as seen by Systems A and B
5
Distributed Relay (C)*
(6.9)
LAG*
MACMAC
Server
Link Agg
MACMAC
MAC MAC
(6.9)(6.9)
MAC
(6.9)
Relay (B)
MAC
(6.9)
MAC
(6.9)
Distributed Relay (C)*
(6.9)
LAG*
MAC
MAC
(6.9)
Relay (A)
IPL
Selected Gateway for this VLAN
• Link Selection still based on 5-tuple hash, so both LAG links carry data.
• Where does the Up MEP go?
![Page 6: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/6.jpg)
Options for MEP Implementation
1. Distribute MEP functionality across the physical DRNI ports.– Requires standardizing how MEP functionality gets distributed.
– Almost certainly requires support from the Intra-Portal Protocol.
2. Distribute MEP functionality across the Intra-Portal Port and the DRNI ports in the system with the selected Gateway.– Distributes MEP functionality among ports in the same physical
system (which is the same problem that arises with today’s LAG).
– Intra-Portal Link is not included in the MA monitored by the MEP.
– MEP functionality moves when the selected Gateway changes.
3. Constrain the Link Selection such that all frames that would pass through the same MEP use the same DRNI link.– VERY restrictive constraint.
4. Are there any other options?
6
![Page 7: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/7.jpg)
2nd Example: DRNI at an I-tagged service interface
7
Carrier BNetwork
Carrier ANetwork
• The service ID on an I-tagged service interface is the I-SID.• Link selection is by I-SID
• Multiple I-SIDs map into a B-VLAN in the Carrier A Network• The B-VLAN is monitored using CFM with Up MEPs at each interface to the
Carrier A Network.
I-taggedServiceInterface*
B
A
B-components (B-BEBs)
* Reference: 802-1Q Figure 25-9 and 26.6.2
![Page 8: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/8.jpg)
I-tagged DRNI as seen by Systems A and B
8
Distributed Relay (C)*
(6.11)
LAG*
MACMAC
MAC MAC
(6.9)(6.9)
MAC
(6.9)
Relay (B)
MAC
(6.9)
MAC
(6.9)
Distributed Relay (C)*
(6.11)
LAG*
MAC
MAC
(6.9)
Relay (A)
IPL
Selected Gateway for this B-VLAN
• Link Selection based on I-SID, so I-SIDs from both LAG links could map to the B-VLAN.
• Where does the Up MEP go?
![Page 9: Link Selection and OAM Version 01 Stephen Haddock July 18, 2012 1](https://reader036.vdocuments.us/reader036/viewer/2022082917/5514b774550346ea6e8b64b7/html5/thumbnails/9.jpg)
Thank You
.