Installation Instructions 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved © 2018 Visa Lighting When using electrical equipment, basic safety precautions should always be followed, including the following: •Read all instructions carefully before installing and save for future use. •Make sure all connections are in accordance with the National Electrical Code and local regulations. •To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture •Service should be performed by qualified personnel. •These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting. ! 1 Linesse Linear Luminaire 3” Recessed LINESSE LINEAR LUMINAIRE 3” RECESSED CV2424 Page 2: Warnings Page 3: Mounting Types and Dimensions Page 4: T-Grid and Joining Fixtures Page 5: Hard Ceiling and Joining Fixtures Page 7: Corners Page 8: Corners – T-Grid and Joining Fixtures Page 9: Corners – Hard Ceiling and Joining Fixtures Page 10: Power Feed

Upload: others

Post on 13-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

Installation Instructions

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

1

Linesse Linear Luminaire3” Recessed

LINESSE LINEAR LUMINAIRE 3” RECESSED

CV2424

Page 2: WarningsPage 3: Mounting Types and DimensionsPage 4: T-Grid and Joining FixturesPage 5: Hard Ceiling and Joining FixturesPage 7: CornersPage 8: Corners – T-Grid and Joining FixturesPage 9: Corners – Hard Ceiling and Joining FixturesPage 10: Power Feed

Page 2: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

2

WARNING

To reduce the risk of death, injury or property damage from fire, electric shock, cuts, abrasions, falling parts and other hazards:

• Installation and maintenance must be performed by a person familiar with the construction and operation of this product and any hazards involved. All applicable codes and ordinances must be followed

• Read this document before installing, servicing or maintaining this equipment. These instructions do not cover all installation, service and maintenance situations. If your situation is not covered, or, if you do not understand these instructions or additional information is required, contact your distributor

Before installing, servicing or maintaining this equipment, follow these general precautions. To reduce the risk of electrocution:

• Make sure the equipment is properly grounded

• Always deenergize the circuit and/or equipment before connecting to, disconnecing from or servicing the equipment

To prevent luminaire row from over-current:

• By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must not exceed the maximum line wire amperage marked on the luminaire and the power feed cord/wire amperage rating whichever is the least

To reduce the risk of fire:

• Use supply conductors with a minimum installation temperature rating as specified on equipment

To reduce the risk of personal injury from cuts, abrasions or falling parts:

• Wear gloves to prevent cuts or abrasions from sharp edges when removing from carton, handling and maintaining this equipment

• Do not use abrasive materials, glass cleaners or other solvents on reflector or lens. These substances may damage equipment and cause parts to eventually break and fall

• Do not install a damaged fixture

Page 3: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

3

MOUNTING TYPES AND DIMENSIONS

Flange Flangeless/Trimless 9/16” GridTegular Lay-in

15/16” GridTegular Lay-in

9/16” GridSlot

Rough-In Width Grid Width

3-11/16”

Mounting Type 3” 4”

Flange 3-5/8” 4-5/8”

Flangeless/Trimless 3-5/8” 4-5/8”

“Rough In” Width

Ceiling Type 3” 4”

9/16” Slot 4” 5”

9/16” Tegular/Lay-in 3-13/16” 4-13/16”

15/16” Tegular/Lay-in 4-1/8” 5-1/8”

Grid Mounting Center Widths

Page 4: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

4

INSTALLATION INSTRUCTIONS FOR MOUNTING IN T-GRID AND JOINING FIXTURES

1. Remove lens.

2. Install hanger brackets on each side of fixture approximately 4” inches in from the ends. For 9/16” lay-in grid, place smaller gap side of bracket towards lens. For other grids place wider gap side towards lens.

3. Set fixture into opening between T-Grid. After

the fixture is set, screw in #8 self threading screws in hanger bracket and attach support wiring to the building and fixtures.

4. Bring conduit and conduit fitting (supplied by others) to the power feed hole location at the end of the housing or in end cap. Make the electrical connections to the building power using the starter harness and plug into the fixture through harness. Use the wiring diagram included to identify wiring.

5. For row mounting fixtures, attach male end of harness to female end of harness. Small lens sections are centered between fixtures to avoid light leak at lens ends.

6. Slide fixture together using sliders that extend from fixtures to insure proper alignment.

7. Screw internal reflectors down to joining fixture.

8. Tuck harness at end of rows and attach end caps using supplied screws.

9. Grid end caps can be adjusted for lay in or Slot T configurations (use extra holes to adjust).

Hanger BracketsApproximately 4”

Smaller Gap Side of Bracket for 9/16” Lay-in Grid

Starter Harness

Building Power Feed

Thru Harness

Support Wire

Mounting Screws

Thru Harness

Sliders

Lens

Fasten extended reflector tabs to joining fixture. break tab at end of run

Fasten endcap to end of run

Page 5: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

5

INSTALLATION INSTRUCTIONS FOR MOUNTING IN HARD CEILING AND JOINING FIXTURES

1. Prepare wall/ceiling with proper rough-in width openings (see chart on page 3).

2. For post sheetrock applications use 5/8” holes on back of fixture. Tie into the building with 1/4” all thread rod (supplied by others).

3. Install building power feed conduit and fitting (supplied by others) through top side of housing or thru end cap of 1st fixture in the continuous run. Make the electrical connections to the building power using the starter harness and plug into the fixture thru harness. Use the wiring diagram included to identify wiring.

4. Insert fixture thru rough-in opening and fasten fixture (hardware supplied by others) to building studs.

• Center fixture in opening

• Predrill holes for screws and countersink 3/16” for “Trimless” fixture (if needed)

Rough-In Width

Flange

Rough-InWidth

Building Power Feed

Slider Channel

Predrill mounting holes in slider channel

Predrill and countersink mounting holes

(if needed)

Do not over tighten

All Thread (supplied by others)Post sheetrock applications

Flangeless

Trimless/FlangelessFlange

3-11/16” 3-11/16”

Page 6: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

6

INSTALLATION INSTRUCTIONS FOR MOUNTING IN HARD CEILING AND JOINING FIXTURES (cont.)

1. For row mounting fixtures attach male end of harness to female end of harness. Small lens sections are centered between fixtures to avoid light leak at lens ends.

2. Slide fixture together using sliders that extend from fixtures to insure proper alignment.

3. Screw internal reflectors down to joining fixture.

4. Tuck harness at end of rows and attach end caps using supplied screws.

5. Replace Lens.

6. Finish mud over flangeless trim making sure no screw heads are exposed.

7. Clean around exposed area.

Starter Harness(1st Fixture)

Through Harness

SlidersLens

Through Harness

Inside View

Fasten extended reflector tabs to joining fixture.

Carefully break tab at end of run

Fasten end cap to end of run

Mud and sand over “Trimless” trim before painting

Page 7: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

7

CORNER INSTALLATION INSTRUCTIONS

Horizontal Drywall Corner Vertical IN Corner

Horizontal Grid Corner

23-1/2”

Flange Corner

Trimless/Flangeless Corner

Flange Corner Flange Corner

Trimless/Flangeless Corner Trimless/Flangeless Corner

Grid Corner

23”Lens Area

20”

23”

20”

Lens Area

23”

Page 8: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

8

CORNER INSTALLATION INSTRUCTIONS FOR MOUNTING IN T-GRID AND JOINING FIXTURES

1. Remove lens and install hanger brackets. For 9/16” lay-in grid, place smaller gap side of bracket towards lens. For other grids, place wider gap side towards lens.

2. Set fixture into opening between T-Grid. Screw in #8 self threading screws in hanger bracket and attach support wiring to the building and fixtures.

3. Bring conduit and conduit filling (supplied by others) to the power feed hole location

at the end of the housing. Make the electrical connections to the building power. Use the wiring diagram included to identify wiring.

4. For row mounting attach harnesses.

5. Center lens sections.

6. Slide fixture together using sliders.

7. Screw internal reflectors down to joining fixture.

8. Tuck harness at end of rows and attach end caps using supplied screws. Replace lens.

9. Grid end caps can be adjusted for lay in or slot T configurations (use extra holes to adjust).

Note: Horizontal grid corners has endcaps and a starter harness provided. Please discard the component not needed for your project. If the harness needs reversed for a left, use the 4” adapter harnesses provide in the hardware kit.

Use Chart on Page 3 to determine Grid mounting widths.

Approximately 4”

Hanger Brackets

Support Wire

Mounting Screws

Through Harness

Lens

Sliders

Smaller Gap Side of Bracket for 9/16” Lay-in Grid

Building Power Feed

Starter Harness

Through Harness

Inside View

Fasten extended reflector tabs to joining fixture.Carefully break tab at end of run

Fasten end cap to end of run

Page 9: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

9

CORNER INSTALLATION INSTRUCTIONS FOR MOUNTING IN HARD CEILING AND JOINING FIXTURES

1. Prepare wall/ceiling with rough-in openings (see chart on page 3.

2. For post sheetrock applications use holes on back of fixture to tie into the building (supplied by others). Remove lens.

3. Install building power feed (supplied by others) thru top side of housing or thru end cap. Attach power to harness using the starter harness and plug into the fixture thru harness. Use the wiring diagram included to identify wiring.

4. Insert fixture thru rough-in opening and fasten fixture (hardware supplied by others) to building studs.

• Center fixture in opening

• Predrill holes for screws and countersink 3/16” for “Trimless/Flangeless” fixture

Vertical IN Corner Vertical OUT Corner Trimless

Rough-In Width

3-11/16”

Flange

Rough-In Width

3-11/16”

Building Power Feed

All Thread (supplied by others)Post sheetrock applications

Slider Channel

Predrill mounting holes in slider channel

Do not over tighten

Flange

Predrill and countersink mounting holes

(if needed)

Trimless/Flangeless

Page 10: LINESSE LINEAR LUMINAIRE 3” RECESSED€¦ · 1717 W Civic Drive, Milwaukee, WI 53209 414-354-6600 Design Modification Rights Reserved 2018 Visa Lighting When using electrical euipment

1717 W Civic Drive, Milwaukee, WI 53209414-354-6600

Design Modification Rights Reserved© 2018 Visa Lighting

When using electrical equipment, basic safety precautions should always be followed, including the following:•Read all instructions carefully before installing and save for future use.•Make sure all connections are in accordance with the National Electrical Code and local regulations.•To avoid possible electric shock, be sure the power supply is turned off before servicing or installing the fixture•Service should be performed by qualified personnel.•These instructions may not cover all details or variations. If additional information is needed, please contact Visa Lighting.!

Publication 762302XX Rev: A – June 2018

Model: CV2424 Linesse Linear SlotPublication: 762302XXDocument Description: Installation Instructions for 3” Linesse Linear Recessed Series Luminaires

10

INSTALLATION INSTRUCTIONS FOR POWER FEED

Insert building power feed using conduit into the fixture feed hole or a 2x4 Junction box (supplied by others). Start with the first fixture and splice wiring according to the wiring diagram below. A starter harness must be used to connect to the through harness that will supply power to adjoining fixtures.

Building Power Feed

Starter Harness

Through HarnessLINE WIRE COLOR CIRCUIT DESCRIPTION

BLK CIRCUIT A—HOT

WHT CIRCUIT A & B– NEUTRAL

RED CIRCUIT B– HOT

GRN GROUNDING

VLT DIMMING CONTROL 1

GRY DIMMING CONTROL 2

ORG EHS or EHF—HOT

WHT/ORG EHS or EHF– NEUTRAL

GRN - GND

GRY - DIM -

VLT - DIM+

BLK - HOT

WHT - NEU

GRN - GND

GRY - DIM -

VLT - DIM+

BLK - HOT

WHT - NEU

LINE-IN FIXTURE

General Wiring Diagram

For special circuitry consult factory