LINE SEIKI
G48G48 SeriesP R E S E T C O U N T E R
DIN 48 X 48 COMPACT SIZE ELECTRONIC PRESET
EASY EDITING ( INDIVIDUAL DIGIT KEYS )
LCD DISPLAY WITH LED BACKLIGHT
PRESCALE KEY LOCK
FREE WRITE
![Page 2: Line Seiki - G48 Preset Counter LCD Backlit](https://reader035.vdocuments.us/reader035/viewer/2022081806/568bc1741a28ab777e8d04b9/html5/thumbnails/2.jpg)
MODELS
Model Digit Preset Power source Input Body length
1 level preset
2 level preset
1 level preset + prewarn
Contact / Open collectorVoltage inputcan be selected byprogramming
Standard size
Short size
Standard size
FRONT PANEL FEATURES
Count display
Editing display
Program item display
count speed
input programming
output programming
output time selection
prescale
selection of decimal point position
write
selection of reset time
key lock protection
preset value indication
prewarn setting
Output indicator
External reset input indicator
External key lock indicator
Individual digit setting keys
Reset key
Mode key
Display key
< 6 digit >
SETTING VALUES
Count Speed 30Hz, 1000Hz, or 5000Hz can be selected by pressing key 1.Input Mode Contact / Open collector or voltage input can be selected beforehand.Count Mode One of the following 5 count modes can be selected:
ADD INPUT
SUBTRACTINPUT
ADD SUBTRACTINPUT
QUADRATUREINPUT
DIRECTIONINPUT
The example shown is open collector input.
The example shown is open collector input.
The example shown is open collector input.
The example shown is open collector input.
The example shown is open collector input.
( 6 Digit )
Input A
Input B
Input A: count input Input B: count prohibit Write in value is 0
( 6 Digit ) Write in valueInput A: count input Input B: count prohibit Write in value is 10
Count value
Input A
Input B
Count value
Subtracts from write-in valueand outputs at preset value
( 6 Digit )
Input A
Input B
Count value
( 6 Digit )
Input A
Input B
Count value
( 6 Digit )
Input A
Input B
Count value
OUTPUT MODE One of the following 6 output modes can be selected.
Output times can in either case be one shot or hold (1st level output in 2 level preset model is either Hold1 or Hold2).
Output occurs only when and continues as long as the current count value is equal to the preset value.
Lower limit comparator output. Comparator outputs are the most suitable for positioning application.1 level preset output is lower limit comparator output.Upper limit comparator output. Comparator outputs are the most suitable for positioning application.1 level preset output is lower limit comparator output.
Upper - Lower limit comparator output. Comparator outputs are the most suitable for positioning application.In 2 level preset model, the 1st preset value is lower comparator out, while 2nd preset value is upper comparator out.Upper 1 - Upper 2 limit comparator output. In 2 level preset model, the 1st and 2nd preset values are upper limit comparator outputs.
Standard Output
Equal output
Lower limit output
Upper limit output
Upper - lower limit output
G48−305
G48−306
G48−315
G48−325
Upper 1 - Upper 2 limit output
6
AC100~240V
AC100~240V
DC12~24V
5
4
62
1
3
23
7
1
3
6 5 4
8 9 10
87
910
IN HzIN
OUTOUT ms
PSDPWRST ms
SETPW
KEY/P
KEY/P RST PWPS D P W S E TI N O U T 1 2
PW21OUTRSTKEY/P
RESET MODE DISP
msHz
9 9 9 9 9 9
− 9 9 9 9 9
− 9 9 9 9 9 9 9 9 9 9 90
− 9 9 9 9 9 9 9 9 9 9 90
− 9 9 9 9 9 9 9 9 9 9 90
0
0
H
HL
L
H
H
L
L
H
H
L
L
H
H
L
L
H
HL
L
0
109
87
65
12
3
01 1 1
2 23
01 1
2 2 2 23
01 1
2 2 23 3
3 3
234
5
6 4 3 2 15
![Page 3: Line Seiki - G48 Preset Counter LCD Backlit](https://reader035.vdocuments.us/reader035/viewer/2022081806/568bc1741a28ab777e8d04b9/html5/thumbnails/3.jpg)
The G48 has 2 operation modes. While initial setting such as selection of input and count methodsis done in the Program Mode, usual counting and presetting are done in the Run Mode.Use the key to enter the Program Mode and the key to return to the Run Mode.
2nd level preset value
BASIC OPERATION
RUN MODE
PROGRAM MODE
1 LEVEL PRESETTYPE
2 LEVEL PRESET TYPE
1 LEVEL PRESET +PREWARN TYPE
count value
preset value
count value
1st level preset value
count value
preset value
count value
count value
prewarn value
count speed input mode count method
key protect
reset time
writeselection of decimal point position
output mode
output time
reset mode
prescale
SETTING VALUES
Output time In case of standard output, preset can either be one shot (pulsed) or latched (hold, hold 1, hold 2).Latched outputs can be programmed as follows:
Latched until a reset signal is sent.
Latched until output 2 goes away.
Latched until a reset signal is sent;independent from output 2.
Setting range in 10ms steps is possible.
1 level preset output (OUT), 2nd level preset output (OUT2) of 2 level model,preset output (OUT) of 1 level preset+prewarn model.
1st level preset output (OUT1) of 2 preset level model,prewarn output (PW) of 1 level preset + prewarn model.
Applicable to OUT, PW, OUT1 or OUT2
Hold
Hold 1
Hold 2
One Shot
Reset Mode One of the following 7 reset modes can be selected. Except for standard output, Mode A is onlyavailable for other output modes. The outputs below refer to 1 level preset models, to the 2ndoutput of 2 level preset model, and main output of 1 level prest+prewarn model.
counts during output.
does not count during output.
does not count after output.
resets at rising edge of output.
resets at falling edge of output.
resets at rising edge of output,display "freeze" during output.resets at falling edge of output,display "freeze:" during ouput.
resettable only forone shot output timeresettable only forone shot output timeresettable only forone shot output time
Mode A
Mode B
Mode C
Mode D
Mode E
Mode F
Mode G
Overrun(without auto-reset)
Auto-reset
Prescale Incoming pulses can be prescaled to display the desired measuring unit.The prescale can be set at any value within the range of 0.001 ~ 99.999Ex.) To display 1 count per 10 pulses, PS value = 0.1.
Decimal Point Position Decimal point position can be selected out of the following settings: no decimal point, 0.0, 0.00, 0.000
Free Writing Any desired value can be written on the display. The counter will add to or subtract from the written value.When resetting is made, count value will be replaced with the written value.
Reset Time Reset time sets minimum pulse time of remote reset signal.Reset time can be set to either 2ms or 20ms.
Key Protect There are 4 protection levels.
Level 1
Level 2
Level 3
Level 4
Lock program
Lock program & front key reset
Lock program & preset
Lock program, front key reset & preset
Protection level can beselected in the Program Mode.
MODE
MODE
DISP
DISP
DISP
DISP
ms
![Page 4: Line Seiki - G48 Preset Counter LCD Backlit](https://reader035.vdocuments.us/reader035/viewer/2022081806/568bc1741a28ab777e8d04b9/html5/thumbnails/4.jpg)
SPECIFICATIONS
MODEL
DISPLAY
NO. OF DIGITS
NO. OF DIGIT SETTING KEYS
SETTING RANGE
PREWARN FEATURE
PRESET LEVEL
INPUT MODE
INPUT SIGNAL
COUNT SPEED
COUNT MODE
COUNT RANGE
INPUT INHIBITION
PRESCALE
DECIMAL POINT POSITION
WRITE
RESET
REMOTE RESET TIME
RESET MODE
MEMORY
OUTPUT
OUTPUT DELAY
TYPE OF OUTPUT
OUTPUT TIME
KEY LOCK
ERROR DISPLAY
POWER SUPPLY
OPERATING TEMPERATURE
POWER CONSUMPTION
SENSOR POWER SOURCE
FRONT PANEL
WEIGHT
DIMENSIONS
Front Panel(common to AC and DC models)
Standard Size (AC Models) Short Body Version (DC model) Clip
The dimension of the clip is 47.5 × 60.5mm.Install the clip into the rear of counter, push forward and clamp into place while holding the counter firmly against the panel from the front.
6.2 99.8 6.2 63.848
48 44.5
44.5
Panel Cut Size : 45 × 45+0.60
+0.60
Specifications are subject to change without prior notice.
G48-305 G48-306 G48-315 G48-325
AC100∼240V−15%, +10%
AC100∼240V−15%, +10%
DC12∼24V−15%, +10%
DC12V 100mA DC12V 100mA
LCD display with backlight ; Digit Size : 10mm × 5mm
Either contact / open collector or voltage input can be selected, depending on programming
Open collector, Sink current 10mA (DC power model: power supply volt / 1.2KΩ) L : 0 ~ 5VVoltage (Input impedance 7KΩ) L : 0 ~ 4V H: 6 ~ 30V, Available to duplex wire DC sensor.
Add, Subtract, Add/Subtract (Add/Subtract individual input, Add/Subtract direction, 90° quadrature input)
Incoming pulses in either add or subtract mode can be inhibited at input B only.
Front panel reset, Remote reset, Auto-reset
2msec or 20msec ( selectable )
Modes A, B, C, D, E, F, G can be selected.Except for standard output, Mode A only is available for other output modes.
Relay output ( 1a ) : load of 250VAC 5A / 30VDC 5A maximum
Relay output ( 30Hz : 20msec. 1000Hz : 7msec. 5000Hz : 7msec. )
1 level preset (standard, equal, lower limit, upper limit) 2 level preset (standard, equal, upper-lower, upper-upper limit)1 level preset + prewarn (standard, equal)
Standard output : one shot ( 10 ~ 9990msec ) or HOLD or HOLD 1 or HOLD 2Equal, Upper, Lower output : Latched only when requirements are full
Key operation can be disabled at 4 protection levels (L1, L2, L3, L4) by selecting in Program Mode and shorting key lock terminals.
In Add/subtract mode, error message will be displayed on the LCD if the count range is exceeded (overflow error : underflow error : )
Approximately 7VA for 240VAC, approximately 1.2W for 24VDC
Approximately 170g ( AC models ) ; 110g ( DC model )
−99999 ∼ 999999
−99999 ∼ 999999
−99999 ∼ 999999
0.001 ∼ 99.999 ( 0 setting is not available )
0.0, 0.00, 0.000, No decimal point
IP54 standards
30Hz, 1kHz, 5kHz (selectable)
E PROM ( 10 years, can be used 10000 times )2
−10°C∼50°C (non-freezing, non-condensing) 45∼85%RH (non-freezing, non-condensing)
6
6
2
0∼999999
1 1 preset + prewarn