lindab construction foils technical catalogue and ... · lindab construction foils technical...

24
Lindab | Construction Foils Lindab construction foils Technical catalogue and application guide

Upload: phungkhue

Post on 22-Apr-2018

226 views

Category:

Documents


5 download

TRANSCRIPT

Lindab | Construct ion Foi ls

Lindab construction foilsTechnical catalogue and application guide

Industrial halls - trapezoid sheet cladding

Mounted roofs and facades with heat insulation

Underlay foils

Underlay foilsVapour barrier

Underlay foil with breather membrane

Internal use vapour barrier

1.2.3.4.

5.

6.7.8.

1.2.34.

.

5.

6.7.8.

1.2.3.

5.

6.7.8.

Residential buildings - with tile effect roofing

Residential and public buildings - standing seam roofing

3

Lindab | Construct ion Foi ls

Table of conTenT

Lindab construction foils

Introduction ......................................................................................4

lindab laf roofing underlay foil ...............................................6(for pitched supported or unsupported roof constructions, without sarking)

lTf 115 breathable roofing underlay .....................................8(for pitched supported or unsupported roof constructions, without sarking)

lTf 135 breathable roofing underlay ...................................10(for pitched supported or unsupported roof constructions, universally appliable)

lTf 180 breathable roofing underlay ...................................12(High breathable polyester based roofing underlay with high heat resistance)

lTf 300 High breathable roofing underlay .........................14(High breathable polyester based roofing underlay with extra high heat resistance)

lSZ 500 breathable membrane for flat sheets ....................16(Breathable membrane with separating layer)

lPZ 110 Vapour barriers .............................................................18(Universal reinforced vapour barrier)

accessories to foils .....................................................................20

lindab anti-condense roof sheets .........................................22

4

Lindab | Construct ion Foi ls

Introduction

Some important technical terms

These product samples and technical catalogue are to summarize the construction foils (underlay foils, vapour barrier) offered to roof and wall structures assembled from Lindab lightweight steel profiles.

It is very important to know, that choosing the proper construction foil is an essential part of the complex design process. The appropriate and durable solution can only be guaranteed in view of all the necessary technical details of the real construction to be realized. Paying attention to every aspect of the designing sectors (e.g. roofing or facade cladding, rainwater systems and insulation, heat- and vapour techniques) is the responsibility of the designer.

• Roofing, roofage:the top layer, coating of the roof structures that is in charge of rainwater diversion.

• level of water tightness:the roofing can be water-proof, acutely water-tight or watertight. The level of required water tightness is basically determined by the inclination of the roof (the lower the inclination, the stricter the requirements).

• Metal (steel) based roofings, roofage:The steel based roofings are typically: self-supported big or small-size boards (tile effect or trapezoid sheets) or completely supported flat roofing (standing seam roofing). Steel materials used for roofings are water-proof itself, but owing to joints, fittings, closed-ends and roof break-throughs watertight or acutely watertight roofings can be shaped. It is important to keep in mind when using steel roofing materials that they ought to reach extreme temperature depending on weather circumstances (they follow the change of temperature relatively fast). They also tend to collect moisture, vapour condensation and water dripping may occur.

• Underlay shell (category):A layer built in under the roofing to increase water tightness (secondary water diversion). Underlay foils, underlay boards (hanged independently or laid on full surface underlay) and waterproof membrane sheets are all classified in this category. The grouping of underlay shells (see table below) and the requirements can be found e.g. in the technical publication of EMSZ federation, the Design and construction guidelines to underlay shells (www.emsz.hu).

All the following attributions should be taken into consideration to choose the appropriate underlay shell: characteristics of the roofing, inclination, function of the attic, type of utilization (uninsulated, not built-in attic or heat insulated, built-in attic), shape of the roof (valleys, superstructures, breakthroughs, etc.) and extraordinary extreme weather impacts (rain, snow, wind) as well.

underlay shells overlapping products position to counter batten support

1.underlay membrane

1.1 waterproof underlay membrane

welded or sealed continuous surface

bitumen or plastic underlay proofing

sheets

over

full boarding support (wooden boards or step secure heat insulation)

1.2 watertight (rainproof) underlay membrane

under

2. underlay sheets laying on full support

2.1windtight underlay sheets

welded or sealed continuous surface or without glue and

sealing; boards tongued and grooved

underlay proofing sheets, underlay

foils, underlay boards

2.2freely overlapped underlay sheets

3.underlay sheets hanging freely

3.roof foils and boards hanging freely without adhesive or sealing;

boards tongued and groovedunderlay foils,

underlay boardsnone

waterproof

very low inclination roof (flat roof)

low inclination roof

high inclination roof

0

0

2-3

1-2

5-10

3-6

20-25

12-14

roof inclination (slope) (%)

roof inclination (slope) (degree)

acutely watertight

watertight

5

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Introduction

• Single- and double ventilated roof structure:In case of single ventilated roofs, the air space is found between roofage and the roof underlay; in the case of double ventilated roofs there is air space between roofage – roof underlay, and also between roof underlay and heat insulation.

• Vapour barrier:High vapour diffusive resistance foil, that is placed on the inner side of the heat insulation in case of heat-insulated, mounted roof or wall.

application table of lindab underlay foils

Some important technical terms

lindab foil/product Short description

condition of application

Type of lindab roofing Inclination of the roof configuration of the roof structure

laf roofing underlay foil (200g/m2)

Topline tile effect roofs, Coverline trapezoid sheets, Seamline SRP Click profile (water sealing underneath the counter batten)

Min. 10-14 degree in general, continuous overlaps is needed under 22 degree

Applicable in case of double ventilated roofs (air layer above and under the foil). Primarily it is recommended in case of unbuilt attics, under wooden counter batten, uninsulated roofings. In case of built-in attics, LAF foil cannot touch the heat insulation.

lTf-115 watertight, breathable underlay foil (115-120g/m2)

Topline tile effect roofs, Coverline trapezoid sheets, Seamline SRP Click profile (water sealing underneath the counter batten)

Min. 14 degree in general, continuous overlaps is needed under 22 degree

Recommended in case of single or double ventilated, insulated roofs. Applicable by hanging independently or laying on heat insulation. Cannot be laid directly on board support. Not recommended to get in direct touch with steel roofing.

lTf-135 watertight, high-tensile breathable underlay foil (135-140g/m2)

Topline tile effect roofs, Coverline trapezoid sheets, Seamline SRP Click profile (water sealing underneath the counter batten)

Min. 14 degree in general, continuous overlaps is needed under 22 degree

Recommended in case of single or double ventilated, insulated roofs. Applicable by hanging independently or laying on heat insulation and board support. Not recommended to get in direct touch with steel roofing.

lTf-180perfect water-tightness, high-tensile, high heat resistance, breathable underlay foil (180g/m2)

Topline tile effect roofs, Coverline trapezoid sheets

Min. 6 degree in general, continuous overlaps is needed under 22 degrees.

Recommended in case of single or double ventilated, insulated roofs. Applicable by hanging independently or laying on heat insulation and board support. Due to the high heat resistance, it is proposed for insulated multi-layer steel roofs.

lTf-300perfect water-tightness, high-tensile, extra high heat resistant, breathable underlay foil (300g/m2)

Topline tile effect roofs, Coverline trapezoid sheets

Min. 6 degree in general, continuous overlaps is needed under 22 degrees.

Recommended in case of single or double ventilated, insulated roofs. Applicable by hanging independently or laying on heat insulation and board support. Due to the high heat resistance, it is proposed for insulated multi-layer steel roofs.

lSZ-500watertight, breathable underlay foil mounted, structured separating layer

Seamline flat sheet roofing (PLX seamed roofing, SRP profile)

Min. 14 degrees in general, continuous overlaps needed under 22 degrees. The application guide should be taken into consideration under 14 degree

Applicable in case of single or non-ventilated roofs both insulated and uninsulated cases, between underlay and the flat sheet roofing. The structured separating layer guarantees the continuous ventilation under the steel sheet. Should be laid directly on full surface support.

lPZ-110increased tensile strength, mesh reinforced, inner side vapour barrier

any kind of roofing Application does not depend on inclination

For multi-layered, mounted, heat-insulated roof or wall structures, on the inner side of the heat insulation. Every over-lapping joint, fitting or transition should be closed air- and vapour-tight.

felt coated roofing sheets

profiled big-board roofing steel sheets provided with vapour holder anti-condense felt coating on inner side

Topline tile effect roofs, Coverline trapezoid sheets

Min. inclination depends on the type of roofing sheet used (Tile effect and LTP20 trapezoid sheets: 14°, LTP45 and LTP35 trapezoid sheets: 6°)

Integrated solution recommended in case of uninsulated, single coated buildings, industrial halls. The felt layer is capable absorbing the vapour condensation on the sheets, and it can dry up in case of appropriate ventilation.

1. top roofing2. batten3. counter batten4. underlay sheeting4*. breathable underlay sheet5. ventilated air space6. heat insulation7. rafter8. vapour barrier9. inside cladding

a,double ventilated roof structure b, single ventilated roof structure

6

Lindab | Construct ion Foi ls

lindab laf roofing underlay foil for pitched supported or unsupported roof constructions, without sarking

Product description

Application guide

• lindab laf construction foil consists of two parts

• The bottom part is 90 mm long, fine polypropylene (PP) string – several technical steps – made from felt (150g/m2)

• One side of the felt is heat treated and covered with polypropylene (PP) melt

• The coating contains aluminium pigments and UV stabilizer

• The specific mass of the products is min. 200g/m2, the width of the roll is 1300mm, length is 50m

• Laf underlay foil is applicable in case of lamellar and hard board coating, low and high inclination roofs. Application can prevent dust, snow-dust, rainwater-jam passing into the attic or in the multi-layered roof structure.

• Top part is watertight, heat-reflector-like, bottom (felt coated) part is hygroscopic, vapour holder. It is moderately breathable from the inner side. It is recommended primarily in case of double ventilated roofs.

• laf underlay foils should be placed on the top of rafters in case of traditional wooden roof structure, and in case of full wooden board underlay be nailed to the boarding.

• the fixation on the rafter should be guaranteed with spacer counter batten. laf underlay foil should be placed perpendicular to the rafter, starting from the eaves, crinkle- and fold-free, with maximum 3-4 cm foil hanging.

• The elongation of the foil has to be guaranteed with at least 10 cm overlapping. In case of rafters the fixation should be done over the rafter (it is not compulsory in case of board underlay)

• The underlay foil should be formed at the eaves as if the rainwater is running on the foil out, it should not soak the facade, eaves or shoulders. The ventilation of roofs with laf underlay foil should be properly designed and appropriate level of ventilation should always be guaranteed under every circumstances. The underlay foil should be led up to the planned height of the flashing in case of chimneys, ventilation elements, other pass-throughs mounted with metal sheet flashings, and the fixation should be guaranteed mechanically or by adhesives. The underlay foil should be continuous under the different metal sheet accessories.

• The construction of laf underlay foil should be designed and organized in a manner that until the final sealing of the roof the wind cannot snap into it or ruin it any way. The roofing should be done within 1-2 weeks after the underlay foil is mounted. The appropriate application temperature is between -40 and +80˚ C.

• The overlapping is recommended to be done parallel to the eaves line in case of steel halls (steel sheet cladding, steel purlins) and typically low inclination roofs.

• To avoid hanging of the foil it should be riveted temporarily to the purlins (until mounting the cladding)

• In case installing the foil perpendicular to the eaves line a galvanized steel wire should be expanded under the overlappings, in the upper plane of the purlins that prevents overhanging.

• Perfect air- and water-tightness – especially in case of low inclination roofs – is only guaranteed by the continuation of the foil rolls, that can be executed with hot air welding, close tacking or by using sealing mastic. The closed air layering improves the efficiency of the heat insulation as well.

a

b LAF underlay foil

Beam support

Galv. steel wire

LPA tile effect sheet

batten

counter batten

LAF underlay foil

rafter

LPA underlay foilLAF underlay foil

(See more details in Tile effect sheeting application guide)

7

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical data EN 13859 – 1:2010

Product name lindab laf roofing underlay foil

Product information Unit Value Tolerance Regulation

Length [m] 50 - EN1848-2:2001

Width [m] 1,3 -0,5% / +0,5% EN1848-2:2001

Thickness [mm] 1,2 - EN1849-2:2010

Specific weight [g/m2] 200 +/-10% EN1849-2:2010

Technical characteristics Unit Value Tolerance Regulation

Fire protection class [class] F – EN13501-1:2007 +A1:2010

Water tightness (at production) [class] W3 – EN13111:2010

Vapour diffusion equivalent air layer thickness (Sd)

[m] 1,04 EN 1931:2000

Tensile force (long/cross) [N/40mm] min. 600 / 600. EN 12311-2:2010

Tensile elongation (long/cross) [%] min.50 / min. 70

Change of size to heat [%] <1 – EN1107-2:2001

Flexibility at low temperature [°C] -15 – EN495-5:2001

Properties after artificial ageing

Water tightness [class] W3 –EN 13859-1:2010 (“app. C”)

Tensile force (long/cross) [%] max. +/-25% –EN 1297:2005; EN 1296:2001

Tensile elongation (long/cross) [%] max. +/-25% –EN 1297:2005; EN 1296:2001

Application area

LAF underlay foil is applicable under low and high inclination, watertight scaled or board roofing for underlayment purposes. Application can prevent dust, snow-dust, rainwater-jam passing into the attic or in the multi-layered roof structure. The roofing foil has upper heat reflection layer and a special lower felt layer that can keep the condense water inside until drying, provided by good ventilation. It is moderately breathable from the inner side. It is recommended primarily in case of double ventilated roofs.

8

Lindab | Construct ion Foi ls

lTf 115 breathable roofing underlayfor pitched supported or unsupported roof constructions, without sarking

Product description

Installation

• lTf 115 is manufactured by thermally bonding two spunbonded polypropylene fabric layers, with a microporous film, between the two layers, to form a breathable waterproof membrane.

• It is fully recyclable.

• The membrane is produced with a grey upper surface and white lower layer.

• lTf 115 is satisfactory for use as unsupported or supported light-weight breather underlay in pitched roof construction without sarking. The special design of lTf 115 provides good tightness against rain water. Extreme water vapour permeability keeps roof construction dry and ventilated under all weather conditions.

• lTf 115 allows any moisture within the construction to pass out of the building while offering some weather protection from rain and snow.

• lTf 115 does not rot, it´s resistant to moulds or pests and it corresponds with health standards.

• lTf 115 may be used also for vertical wall constructions as air-leakage barrier. Therewith, a closed system for heat insulation and rain, snow, dampness and dust penetration protection is created.

• Before installing lTf 115 ensure that the surfaces to be covered are firmly fixed, clean, dry and smooth

• When installed, the lTf 115 is laid horizontally across the roof slope over insulation or rafters and secured with non corrosive flat-headed nails or staples. Batten spacing should not exceed 1,2 m.

• Counter battens at least 25 mm thick are then installed over the underlay and fixed through to the rafters. The battens for tiling are fixed to the counter battens leaving space between the underlay and the battens for drainage.

• When lTf 115 is applied on an impregnated rafters or counter batten, it can be realized only after the paint is dry.

• Lay lTf 115 loose, flat and without wrinkles.

• Laps should be preferably sealed with LRG-2 tape. Adhesive PVC should not be used for sealing and joining laps.

• Attention to details is important. Avoid blockages where possible that would otherwise prevent the free drainage of water.

Roll specifcation

Width of underlay 1,50 m

Roll size 50 m

Area per roll 75 m2

Sd 0,02 m

Weight per roll 9,5 kg

Storage

• Rolls should be stored flat on a clean, level surface and kept under cover from sunlight.

9

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical data EN 13859 – 1:2010

Product name lindab lTf-115 breathable underlay foil

Product information Unit Value Tolerance Regulation

Length [m] 50 – EN1848-2

Width [m] 1,5 -0,5% / +1,5% EN1848-2

Straightness - conforming – EN1848-2

Specific weight [g/m2] 120 -10 / +10 EN1849-2

Visible defects - none – EN1850-2

Technical characteristics Unit Value Tolerance Regulation

Fire protection class [class] E –EN13501-1 EN11925-2

Water tightness (at production) [class] W1 –EN1928EN13111

Vapour diffusion equivalent air layer thickness (Sd)

[m] 0,02 -0,01 / +0,015EN12572 EN1931

Tensile force (long/cross) [N/50mm] 260 / 170 -25 / +30…40EN12311-2 EN13859-2

Tensile elongation (long/cross) [%] 50 / 70 -20 / +20…30EN12311-2 EN13859-1,2

Resistance to tearing [N] 120 / 140 -30…35 / +50…55EN12310-2 EN13859-1,2

Change of size to heat [%] <2 EN1107-2

Flexibility at low temperature [°C] -20EN1109 EN495-5

Resistance to penetration of air [m3/m2/h/100Pa] 0,01EN12114 EN13859-1,2

Properties after artificial ageing

Water tightness [class] W1 – EN1297

Tensile force (long/cross) [%] <20 – EN1296

Tensile elongation (long/cross) [%] <35 – EN13859-1,2

Application area

Breather roofing underlay for single or double ventilated roofs with low to high inclination and for wall structures as well – as secondary protection preventing dust, snow-dust and moisture getting under the cladding. It is applicable by hanging independently or lying on the outer surface of the heat insulation. Wind and waterproof underlay foil only in case of keeping a minimum inclination and with appropriate overlaps. It is not applicable directly on board underlay.

10

Lindab | Construct ion Foi ls

lTf 135 breathable roofing underlayfor pitched supported or unsupported roof constructions, universally appliable

Product description

Installation

• lTf 135 is manufactured by thermally bonding two spunbonded polypropylene fabric layers, with a microporous film, between the two layers, to form a breathable waterproof membrane.

• It is fully recyclable.

• The membrane is produced with grey upper layer and white lower layer.

• lTf 135 is satisfactory for use as unsupported or supported breather underlay in pitched roof construction. It can be used both, for timber sarking roofs or can be laid directly over

thermal insulation. A ventilation space between lTf 135 and the insulation is not required and the full height of the rafters can be used for thermal insulation.

• The special design of lTf 135 provides an excellent resistance against rain water.

• Extremely high water vapour permeability keeps roof construction dry and ventilated under all weather conditions. The roof can actually breathe!

• lTf 135 does not rot, it´s resistant to of moulds or pests and it corresponds with health standards.

• Before installing lTf 135 ensure that the surfaces to be covered are firmly fixed, clean, dry and smooth.

• When installed, the lTf 135 is laid horizontally across the roof slope over insulation or rafters and secured with non corrosive flat-headed nails or staples. Batten spacing should not exceed 1,2 m.

• Counter battens at least 25 mm thick are then installed over the underlay and fixed through to the rafters. The battens for tiling are fixed to the counter battens leaving space between the underlay and the battens for drainage.

• When lTf 135 is applied on an impregnated rafters or counter batten or timber sarking, it can be realized only after the paint is dry.

• Lay lTf 135 loose, flat and without wrinkles.

• Where possible reduce the number of end laps to a minimum by using full rolls of sheeting. The laps should be at least 150mm wide.

• Laps should be preferably sealed with LRG-2 tape. Adhesive PVC should not be used for sealing and joining laps.

• Attention to details is important. Avoid blockages where possible that would otherwise prevent the free drainage of water.

Roll specifcation

Width of underlay 1,50 m

Roll size 50 m

Area per roll 75 m2

Sd 0,02 m

Weight per roll 11 kg

Storage

• Rolls should be stored fat on a clean, level surface and kept under cover from sunlight.

11

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical data EN 13859 – 1:2010

Product name lindab lTf-135 breathable underlay foil

Product information: Unit Value Tolerance Regulation

Length [m] 50 – EN1848-2

Width [m] 1,5 -0,5% / +1,5% EN1848-2

Straightness – conforming – EN1848-2

Specific weight [g/m2] 140 -10 / +10 EN1849-2

Visible defects – none – EN1850-2

Technical characteristics Unit Value Tolerance Regulation

Fire protection class Unit E –EN13501 EN11925-2

Water tightness (at production) [class] W1 –EN1928EN13111

Vapour diffusion equivalent air layer thickness (Sd)

[m] 0,02 -0,01 / +0,015EN12572EN1931

Tensile force (long/cross) [m] 290 / 205 -30 / +45...50EN12311-2 EN13859-1

Tensile elongation (long/cross) [N/50mm] 55 / 80 -25...20 / +25...30EN12311-2 EN13859-1

Resistance to tearing [%] 150 / 180 -50...40 / +70EN12310-2 EN13859-1

Change of size to heat [N] <2 – EN1107-2

Flexibility at low temperature [°C] -40 –EN1109EN495-5

Resistance to penetration of air [m3/m2/h/100Pa] N/A –EN12114 EN13859-1

Properties after artificial ageing

Water tightness [class] W1 – EN1297

Tensile force (long/cross) [%] <20 – EN1296

Tensile elongation (long/cross) [%] <35 – EN13859-1

Application area

High tensile breather underlay foil for single or double ventilated roofs with low to high inclination roof structures; as secondary protection preventing dust, snow-dust and moisture getting under the cladding. Wind and waterproof underlay foil in case of a minimum inclination and with appropriate overlaps. It is applicable directly on heat insulation or full board underlay.

12

Lindab | Construct ion Foi ls

lTf 180 breathable roofing underlayHigh breathable polyester based roofing underlay with high heat resistance

Description and use

Installation guideline

• lTf 180 is a 2 layer roofing membrane, consisting of bottom spunbonded polyester layer, and special coating top layer.

• lTf 180 is designed for pitched supported and unsupported roofing construction, even in case of very low pitch— 6° onward.

• lTf 180 is satisfactory for all roof coverings.

• lTf 180 is rain resistant roofing underlay—when being sealed with sealing accesories accordingly to installation guidelines.

• lTf 180 is available also with integrated sealing tapes on both sides for quick and easy-to-make installation.

• lTf 180 can be used also as wind-break underlay for wall constructions.

• The membrane is to be installed printed side up.

• The installation starts from gutter side of the roof upward to the ridge, horizontally, with overlaps of 15 cm.

• In case of roof slope under 22°, sealing of overlaps with sealing tape is recommended. Vertical connection of lTf 180 must be made over the rafter.

• The membrane is fixed to boarding or rafters by non corrosive fllat headed nails or staples and only over the overlapping area.

• In case of any construction elements penetrating the lTf 180, sealing the penetration by tape LRG-15 is strongly recommended.

• To create rain -resistant sealing, LRG-TPK is to be used. It should be used for roofs with slope under than 15°anyway.

• lTf 180 when being uncovered, can not be weathered for more, than 6 months from installation. It must be covered by roof covering within this time period.

• The roof covering has to be ventilated accordingly to manufacturer ´s installation instructions, and proper ventilation gap on top of lTf 180 must be obtained throughout the installation area.

Roll specification

Width of underlay 1,50 m

Roll size 50 m

Area per roll 75 m2

Sd 0,02 m

Weight per roll Kb. 21 kg

Installation accessories

LRG-TPK One—side adhesive sealing tape for use underneath counter-battens.

LRG-1S Adhesive tape for sealing of penetrating construction elements—pipes, cables, windows etc.

1.2.3.4.

5.

6.7.8.

1.2.34.

.

5.

6.7.8.

1.2.3.

5.

6.7.8.

Single ventilated roof structure, underlay foil laid directly on board underlay

Heat insulated, mounted sandwich hall roof

1. Battens or timber sarking

2. Counter battens3. Roofing rain

resistant membrane LTF300

4. Timber sarking5. Thermal insulation

between the rafters

6. Thermal insulation under the rafters

7. Vapour barrier8. Frame + interior

face

1. Lindab trapezoid sheet2. Ventilation spacer (optional)3. Breathable construction foil4. LPO thermal bridge reducer5. Vapour barrier6. Lindab trapezoid sheet

13

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical data EN 13859 – 1:2010

Product name lindab lTf-180 breathable underlay foil

Product information: Unit Value Tolerance Regulation

Length [m] 50 - EN1848-2

Width [m] 1,5 -0,5% / +1,5% EN1848-2

Straightness - conforming - EN1848-2

Specific weight [g/m2] 180 -15 / +15 EN1849-2

Visible defects - none - EN1850-2

Technical characteristics Unit Value Tolerance Regulation

Fire protection class [class] E –EN13501 EN11925-2

Water tightness (at production) [class] W1 –EN1928 EN13111

Vapour diffusion equivalent air layer thickness (Sd)

[m] 0,04 -0,02 / +0,02EN12572 EN1931

Tensile force (long/cross) [N/50mm] 300 / 210 -50…20 / +50…70EN12311-1 EN13859-1

Tensile elongation (long/cross) [%] 25 / 25 -10 / +15EN12311-1 EN13859-1

Resistance to tearing [N] 110 / 120 -20 / +40EN12310-1 EN13859-1

Change of size to heat [%] <1 – EN1107-2

Flexibility at low temperature [°C] -30 –EN1109 EN495-5

Resistance to penetration of air [m3/m2/h/100Pa] N/A –EN12114 EN13859-1

Temperature resistance [°C] -40 / +100 – –

Hydrostatic pressure test [cm] n.a. – EN20811

Properties after artificial ageing

Water tightness [class] W1 –EN13859-1 Annex C

Tensile force (long/cross) [N/50mm] 270 / 200 -40…30 / +70EN13859-1 Annex C

Tensile elongation (long/cross) [%] 22 / 22 -8 / +13EN13859-1 Annex C

Application area:

High temperature and tensile force resistance breather underlay foil for single or double ventilated roofs with low to high inclination roof structures as secondary protection preventing dust, snow-dust and moisture getting under the cladding. It is applicable by hanging independently or lying on the outer surface of the heat insulation and lying on full surface board underlay. Wind and waterproof underlay foil in case of a minimum inclination and with appropriate overlaps.

14

Lindab | Construct ion Foi ls

lTf 300 High breathable roofing underlayHigh breathable polyester based roofing underlay with extra high heat resistance

Description and use

Installation guideline

• lTf 300 is a 2 layer roofing membrane, consisting of bottom spunbonded polyester layer, and special coating top layer with temperature resistance 120° C

• lTf 300 is designed for pitched supported and unsupported roofing construction, even in case of very low pitch- 6° onward.

• lTf 300 is satisfactory for all roof coverings

• lTf 300 is rain resistant roofing underlay-when being sealed with sealing accesories accordingly to installation guidelines.

• lTf 300 is available also with integrated sealing tapes on both sides for quick and easy-to-make installation.

• lTf 300 can be used also as wind-break underlay for wall constructions.

• The membrane is to be installed printed side up.

• The installation starts from gutter side of the roof upward to the ridge, horizontally, with overlaps of 15 cm.

• In case of roof slope under 22°, sealing of overlaps with sealing tape is recommended (integrated, or LRG-15). Vertical connection of lTf 300 must be made over the rafter.

• The membrane is fixed to boarding or rafters by non corrosive flat-headed nails or staples and only over the overlapping area.

• In case of any construction elements penetrating the lTf 300, sealing the penetration by LRG-15 tape is strongly recommended.

• To create rain-resistant sealing, LRG-TPK is to be used. It should be used for roofs with slope under than 15° anyway.

• lTf 300 when being uncovered, can not be weathered for more, than 9 months from installation. It must be covered by roof covering within this time period.

• The roof covering has to be ventilated accordingly to manufacturer’s installation instructions, and proper ventilation gap on top of lTf 300 must be obtained throughout the installation area.

• To create rain-resistant roof construction, sealing of counterbattens with the tape is necessary.

Roll specification

Width of underlay 1,50 m

Roll size 50 m

Area per roll 75 m2

Sd 0,04 m

Weight per roll Kb. 23 kg

Installation accessories

LRG-TPK One-side adhesive sealing tape for use underneath counter-battens

LRG-1S Adhesive tape for sealing of penetrating construction elements-pipes, cables, windows etc 1.

2.3.4.

5.

6.7.8.

1.2.34.

.

5.

6.7.8.

1.2.3.

5.

6.7.8.

Single ventilated roof structure, underlay foil laid directly on board underlay

Heat insulated, mounted sandwich hall roof

1. Battens or timber sarking

2. Counter battens

3. Roofing rain resistant membrane LTF 300

4. Timber sarking

5. Thermal insulation between the rafters

6. Thermal insulation under the rafters

7. Vapour barrier

8. Frame + interior face

1. Lindab trapezoid sheet2. Ventilation spacer (optional)3. Breathable construction foil4. LPO thermal bridge reducer5. Heat insulation between purlins 6. Vapour barrier7. Lindab trapezoid sheet

15

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical data EN 13859 – 1:2010

Product name lindab lTf-300 breathable underlay foil

Product information Unit Value Tolerance Regulation

Length [m] 50 – EN1848-2

Width [m] 1,5 -0,5% / +1,5% EN1848-2

Straightness – conforming – EN1848-2

Specific weight [g/m2] 300 -25 / +25 EN1849-2

Visible defects – nincs – EN1850-2

Technical characteristics Unit Value Tolerance Regulation

Fire protection class [class] E –EN13501 EN11925-2

Water tightness (at production) [class] W1 –EN1928EN13111

Vapour diffusion equivalent air layer thickness (Sd)

[m] 0,04 -0,02 / +0,04EN12572EN1931

Tensile force (long/cross) [N/50mm] 320 / 200 -60…30 / +60…70EN12311-2 EN13859-1

Tensile elongation (long/cross) [%] 30 / 35 -15 / +15EN12311-2 EN13859-1

Resistance to tearing [N] 130 / 140 -30 / +40EN12310-2 EN13859-1

Change of size to heat [%] <1 – EN1107-2

Flexibility at low temperature [°C] -40 –EN1109EN495-5

Resistance to penetration of air [m3/m2/h/100Pa] n.a. –EN12114 EN13859-1

Temperature resistance [°C] -40 / +120 – –

Hydrostatic pressure test [cm] >100 – EN20811

Properties after artificial ageing

Water tightness [class] W1 –EN13859-1 Annex C

Tensile force (long/cross) [N/50mm] 310 / 190 -60…30 / +60…70EN13859-1 Annex C

Tensile elongation (long/cross) [%] 28 / 33 -14 / +14…15EN13859-1 Annex C

Application area

Extra high temperature and tensile force resistance breather underlay foil for single or double ventilated roofs with low to high inclination roof structures as secondary protection preventing dust, snow-dust and moisture getting under the cladding. It is applicable by hanging independently or lying on the outer surface of the heat insulation and lying on full surface board underlay. Wind and waterproof underlay foil in case of a minimum inclination and with appropriate overlaps.

16

Lindab | Construct ion Foi ls

lSZ 500 breathable membrane for flat sheetsBreathable membrane with separating layer

Product description

Installation

• lSZ 500 is manufactured as 4-layer product consisting of vapour permeable waterproof membrane with a structured polypropylene separating layer.

• It is fully recyclable. lSZ 500 is satisfactory for use in ventilated and nonventilated pitched roofs with metal standing seam roof covering (copper, Zinc, Aluminium, stainless steel, etc.).

• Vapour permeable waterproof underlay allows the evaporation of the moisture from the inner space of building and protects the thermal insulation against any external moisture that may penetrate the outer metal standing seam roof covering.

• The structured separating layer provides an air space below metal standing seam roof covering and allows ventilation of the moisture from the underside of metal roof covering. It protects covering against corrosion.

• Any moisture built up between the outer metal roof covering and lSZ 500 will be channeled to the eaves due to the nature of the 8 mm high structured separating layer. LSZ 500 reduces transmission of external sounds, for example rain hammer.

• lSZ 500 is laid between the timber deck or insulation and the outer metal standing seam roof covering.

• It can be laid either horizontally or vertically, overlapped. It is secured with non corrosive flatheaded nails or staples on the overlap.

• When lSZ 500 is applied on an impregnated rafters or timber sarking, it can be realized only after the paint is dry.

• Horizontal overlaps should be preferably sealed and vertical overlaps must be sealed with connecting tape. Adhesive PVC should not be used for sealing and joining laps.

Roll specifications

Width of underlay 1,5 m

Width of separating layer 1,4 m

Length of roll 25 m

Area per roll 37,5 m

Area of separation layer 35 m2

Diameter of roll 50 cm

Storage

Rolls should be stored standing on a clean, level surface and kept under cover from sunlight.

a) without ventilation

b) ventilation under full boarding

Physical properties Test method UnitsMean results

Weight EN 1849-2 g/m2 500

Tensile strength EN 12311-1 N/5cmMD 310

CD 215

Nail tear resistance EN 12310-1 N/20cmMD 165

CD 130

Resistance to water penetration

EN 1928 W1

Sd value EN ISO 12572 m 0,02

Flammability EN 13501 class E

17

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical data EN 13859 – 1:2010

Product name:lindab lSZ-500 underlay membrane with separating layer

Product information: Unit Value Tolerance Regulation

Length [m] 25 – EN1848-2

Width [m] 1,5 -0,0075 / +0,0225m EN1848-2

Straightness – conforming – EN1848-2

Specific weight [g/m2] 500 -50 / +50 EN1849-2

Visible defects – nincs – EN1850-2

Technical characteristics Unit Value Tolerance Regulation

Fire protection class [class] E –EN13501 EN11925-2

Water tightness (at production) [class] W1 –EN1928 EN13111

Vapour diffusion equivalent air layer thickness (Sd)

[m] 0,02 -0,01 / +0,02EN12572 EN1931

Tensile force (long/cross) [N/50mm] 310 / 215 -40…30 / +20…40EN12311-2 EN13859-1

Tensile elongation (long/cross) [%] 45 / 70 -15 / +15EN12311-2 EN13859-1

Resistance to tearing [N] 170 / 190 -35…30 / +75…80EN12310-2 EN13859-1

Change of size to heat [%] <2 – EN1107-2

Flexibility at low temperature [°C] -20 –EN1109 EN495-5

Resistance to penetration of air [m3/m2/h/100Pa] N/A –EN12114 EN13859-1

Properties after artificial ageing

Water tightness [class] W1 – EN1297

Tensile force (long/cross) [%] <20 – EN1296

Tensile elongation (long/cross) [%] <40 – EN13859-1

Application area

Breather underlay foil with mounted, structured separating layer. It is applicable in case of single ventilated or non-ventilated, low to high inclination roof structures under flat sheet cladding as secondary protection against dust, snow-dust and moisture. The 8 mm high structured separating layer ensures the continuous ventilation, the diversion of moisture, thus the protection of the steel sheet against corrosion. It is to be laid directly on full surface underlay (e.g. board), wind and waterproof underlay foil in case of a minimum inclination and with appropriate overlaps.

Physical properties Test method UnitsMean results

Weight EN 1849-2 g/m2 500

Tensile strength EN 12311-1 N/5cmMD 310

CD 215

Nail tear resistance EN 12310-1 N/20cmMD 165

CD 130

Resistance to water penetration

EN 1928 W1

Sd value EN ISO 12572 m 0,02

Flammability EN 13501 class E

18

Lindab | Construct ion Foi ls

lPZ 110 Vapour barriersUniversal reinforced vapour barrier

Product description

Installation

• lPZ 110 is manufactured as polyolefine multilayer reinforced vapour barrier in transparent colour.

• lPZ 110 seals well against moisture and vapour penetration, regardless if it is used in pitched or flat roof construction, vertical wall construction or in ceiling.

• lPZ 110 is used in combination with an exterior vapour permeable underlay. Combination of perfectly vapourtight layer beneath the insulation and breathable underlay to the outside ensures avoiding of spontaneous moisture condensation inside of thermal insulation, thus faultless function of thermal insulation is ensured.

• lPZ 110 is placed parallel or crosswise onto the rafters, directly beneath the thermal insulation.

• AII overlaps should be sealed with sealing tape.

• Irregularities, such as masonry openings or wall junctions have to be sealed with sealing tape preferably.

• The sealing assures vapour and air tightness, giving you prevention of moisture penetration into the thermal insulation.

• lPZ 110 is easy to install, universal vapour barrier suitable for its purpose of use: barrier against vapour and moisture penetration.

• The easy-to–handle packaging makes work easily and comfortable.

Roll specification

Width of underlay 1,50 m

Roll size 50 m

Area per roll 75 m2

Sd 40

Weight per roll 8,75 kg

Storage

• Rolls should be stored flat on a clean, level surface and kept under cover from sunlight

Packaging

• Every pallet is wrapped individually in polyethylene film. Label is attached to each roll.

Lightweight steel framing, heat insulated wall construction

Steel wall frame structure

LPZ110 inside vapour barrier

Fibred heat insulation

Outside cladding

Industrial steel hall structure, heat insulated trapezoid wall and roof cladding

Outside cladding

Breathable underlay foil

Fibre heat insulation

LPZ110 inside vapour barrier

Breathable underlay foil

Fibred heat insulation

LPZ110 Vapour barrier

Overlaps with adhesive tape

Built-in attic with heat insulated wooden roof structure

19

Lindab | Construct ion Foi ls

Steel wall frame structure

LPZ110 inside vapour barrier

Fibred heat insulation

Outside cladding

Outside cladding

Breathable underlay foil

Fibre heat insulation

LPZ110 inside vapour barrier

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical data EN 13859 – 1:2010

Product name lindab lPZ-110 vapour barrier foil

Product information Unit Value Tolerance Regulation

Length [m] 50 – EN1848-2

Width [m] 1,5 -0,5% / +1,5% EN1848-2

Straightness – conforming – EN1848-2

Depth [mm] 0,22 -0,02 / +0,02 EN1849-2

Specific weight [g/m2] 110 -10 / +10 EN1849-2

Visible defects – none – EN1850-2

Technical characteristics Unit Value Tolerance Regulation

Fire protection class [class] F –EN13501-1 EN11925-2

Water tightness (at production) [class] conforming – EN1928

Vapour diffusion equivalent air layer thickness (Sd)

[m] 40 -10 / +10 EN1931

Tensile force (long/cross) [N/50mm] >220 / >190 –EN12311-2 EN13859-1

Tensile elongation (long/cross) [%] >15 / >15 –EN12311-2 EN13859-1

Resistance to tearing [N] >155 / >145 –EN12310-2 EN13859-1

Determination of resistance to impact – N/A EN12691

Resistance to deformation under load – N/A EN13984

Resistance to alkali – N/AEN13984 EN12311-2

Properties after artificial ageing

Water tightness – conforming –EN1296 EN1931

Application area

Mesh reinforced, increased tensile strength underlay foil to be used against vapour and moisture penetration in case of insulated wall and roof structures on the inner side. Its role is to prevent the moisture penetration into the heat insulation from the inside. Every overlap, joint and connections should be closed air and watertight with appropriate accessories (adhesive tape, sealing mastic).

Breathable underlay foil

Fibred heat insulation

LPZ110 Vapour barrier

Overlaps with adhesive tape

20

Lindab | Construct ion Foi ls

Product Unit Picture Description, application area

LRG-2Roll

(38mm x 50m)

Double sided adhesive tape for water-proof elongation and overlap. The surfaces to be jointed should be devoid of grease, oil and other contamination or mechanical pressure. Perfectly applicable in low temperature as well.

LRG-1SRoll

(38mm x 50m)

Single sided adhesive tape for waterproof sealing in case of pass-through elements (pipe, cable, skylight). Sticks perfectly to clean and dust-free wooden, brick and concrete surfaces. It is applicable to repair smaller damages of the underlay foil.

LRG-TPKRoll

(50mm x 15m)

Single sided, butyl rubber adhesive tape for connection between underlay foil and counter batten to ensure water-tightness at nail downs. The surface should be free from grease, oil and other contamination or mechanical pressure.

LRG-2PZRoll

(15mm x 45m)

Double sided, butyl rubber adhesive tape for joint of vapour barriers. Applicable for smaller damages on surface and for sealing and closing of pass through. Sticks perfectly to clean and dust-free plastic, wooden and steel surfaces.

LTMTube(315g)

Sealing mastic for closing the edge of vapour barrier, connecting to other structures (dust-free brick, wood, concrete or other surfaces).

accessories to foils

Lindab construction foil

Joints, overlaps Closing of

break-through closing of edges

Water tightness at nails on counter

battens

LTF-115 LRG-2* LRG-1S** LRG-1S** LRG-TPK*

LTF-135 LRG-2* LRG-1S** LRG-1S** LRG-TPK*

LTF-180 factory adhesive lane LRG-1S** LRG-1S** LRG-TPK*

LTF-300 factory adhesive lane LRG-1S** LRG-1S** LRG-TPK*

LSZ-500 LRG-2* LRG-1S** LRG-1S** LRG-TPK*

LPZ-110 LRG-2PZ** LRG-2PZ** LTM**

* compulsory to use under 22° inclination**compulsory to use under every circumstances

21

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Product name accessories to construction foils

Product information

LRG-2

roll size: 38mm x 50mmaterial PET polyester carrier layer

adhesive layer 240 g/m2 (polyacryl)

adhesion 30...50 N/25mm

temperature range -40...+100°C

temperature resistance +130°C (short time)

storage temperature +5...+25°C

work in temperature -10...+40°C

LRG-1S

roll size: 50mm x 25 mmaterial PP polypropylene textile and coating

adhesive layer polaycryl

total depth 0,62mm

tensile strength >70N/25mm

tensile elongation 50-100%

temperature range -30…+80°C

storage temperature +5…+25°C

work in temperature +5…+40°C

LRG-TPK

roll size: 50mm x 15mmaterial PE polyester carrier layer

adhesive layer PIB butyl rubber

total depth ~0,9mm

temperature range -30…+80°C

storage temperature +5…+25°C

work in temperature +5…+40°C

LRG-2PZ

roll size: 15mm x 45mmaterial butyl rubber

total depth ~1mm

tensile elongation 400%

UV stability very good

temperature range -40…+90°C

storage temperature +5...+20°C max. 1 year

work in temperature +5…+40°C

LTM

tube: 315gdry time 15 min.

material need (with 4mm doser) 20m long joint

work in temperature -20…+80°C

work in temperature +5…+40°C

storage unopened tube; ventilated dry room; max. 30°C

Technical data EN 13859 – 1:2010

22

Lindab | Construct ion Foi ls

Principles of application:1. The natural warming of the steel roof sheet due to changes in the weather conditions can partly ensure the drying of the moisture held

in the felt layer. Although continuous ventilation of the inner room with openings for air movements into and out of the building should be granted with adequate design and construction.

2. The anti-condense felt has capillarity characteristics, and thus it is important to prevent rain water infiltrating inside through the felt layer at overlaps. The felt is not applied on the sidelaps of the profile by factory made production, which guarantees the protection from infiltration. Through technological reasons of production the felt coating is continuous on the whole length of the sheet, thus in case of critical places (in case of transversal overlapping 5-10 cm, in case of the last panel where the water runs off to the gutter, around 5 cm) the capillary absorption should be prevented with manual solution. This can be done with local removal of the felt layer, burning, hot-air melting or water based lacquer paint.

lindab anti-condense roof sheets

Product description, applicationLindab roof profiles (trapezoid, tile effect roofing) are optionally available with anti-condense (capable to absorb condensation) lower felt coating. The manufactured installation of the felt ensures the strong and durable adhesion, the evenly high technical quality.

Role of the anti-condense felt layer:A special characteristic of the single-layered, steel sheet roofing is that condensation may occur on the inner (lower) surface under certain atmospheric circumstances (dew-point temperature). Such moisture can damage the building structure under the roofing and/or the material and equipment stored in the building in the form of water dripping. Special lower felt layering with high anti-condense capability serves the prevention of harmful dripping. Its further positive attribute is that it is non-burnable, resists to bacteria and has favourable impact on the sound insulation of single-coated steel roofing.

Picture 3. Capillary absorption should be prevented at overlapping and at eaves overhanging

longitudinal overlapping and eaves overhang (on-site solution required!)

sidelap joint (produced without felt covering)

a b

Picture 4. Prevention of capillary absorption with on-site burning (a) or with water based lacquer (b)

Picture 2. The adequate and inadequate ventilation in case of insulated buildings with un-insulated roofing.

Picture 1. The adequate and inadequate ventilation in case of un-insulated buildings.

anti-condense felt layer

sidelap joint (produced without felt covering)

upper profile of trapezoid sheet

anti-condense felt

anti-condense felt layer

water based lacquer

sidelap joint (produced without felt covering)

23

Lindab | Construct ion Foi ls

Lindab Kft. H-2051 Biatorbágy, Állomás u. 1/a. • Telefon: +36 23 531-300 www.lindab.hu

Technical dataÉME A-229/2003; TMI-208/2008

Product namelindab tile effect and trapezoid sheets with anti-condense felt coating

Product information Unit Value Tolerance Standards

Production length: [mm]according to the

steel sheetEN10346

Covering width [mm]according to the

steel sheetEN10346

Depth of steel sheet [mm]according to the

steel sheetEN10346

Specific weight of steel profile [kg/m2]according to the

steel sheet

Specific weight of the felt layer [g/m2] 110 -10% / +10% EN 29073 - 1

Specific weight of felt adhesive [g/m2] 19 -10% / +10% EN 29073 - 1

Width of the felt layer [mm] 1,0 -10% / +10% EN 29073 - 2

Technical characteristics Unit Value Tolerance Standards

Fire protection class (colour coating max 25 ym)

[class] A2-s1,d0 – EN13501-1

Fire protection class (colour coating 25-50 ym)

[class] A2-s2,d0 – EN13501-1

Adhesion of felt [N/mm2] min. 0,1 – EN ISO 4624

Moisture holding capacity (inclination 0°)

[g/100cm2] 14,3 – DIN 53923

Moisture holding capacity (inclination 45°)

[g/100cm2] 10,6 – DIN 53923

Moisture holding capacity (inclination 90°)

[g/100cm2] 8,1 – DIN 53923

Heat diversion factor [W/mK] 0,038 – DIN 52612

Application area

It is recommended in case of un-insulated, single layer steel roofing. The felt layer applied under production circumstances on the backside of the roof profiles are suitable for holding the moisture convergence and preventing water dripping. The room under the roofing should be ventilated appropriately, and the felt layer should be removed at overlappings and eaves overhanging. The felt layer is non-burnable, resists to bacteria and has favourable impact on the sound insulation of single-coated steel roofing.

Lindab | Construct ion Foi lsR

eg n

o. 2

012/

01

2051 Biatorbágy,Állomás u. 1/A.Tel.: +36-23-531-300Fax: +36-23-310-703www.lindab.hu

lindab Profil

Lindab Profile is a branch of the Lindab Group,

developing, manufacturing and marketing efficient,

economical and aesthetic steel and metal sheet

solutions for the building industry.

Lindab’s product range extends from a wide choice

of structural components up to lightweight steel

building systems, which can fulfil industrial, commercial

and residential purposes alike.

Lindab Profile is represented in more than 30 countries

all over Europe. Its headquarters are to be found in

Bastad, southern Sweden.