SPECIFICATION MEASUREMENTSMaximum Screen Height 800mm (31.5")
Screen Sizes (approx.) 55"- 60"
Maximum Lifting Capacity 50Kg (110lb)
Maximum Lifting Capacity (Marine) 30Kg (66lb)
Internal Cabinet Height 950mm (37.4")
Decibel Rating 52 dB
Packaging Dimensions 1150 x 850 x 330mm (45.3 x 33.5 x 13")
Shipping Weight 36Kg (79lb)
Movement Type Motorised
Power Supply Required 110V - 240V AC
Power Consumption 250 - 500W
Power Consumption Standby 3W
Mounting Patterns Supported VESA 400, 300, 200 W x 400, 300, 200 H
Control Options IR Remote, RS232, Contact Closure, RF Available
Product Options / Features Specific B&O and Loewe mounts / adapters, Custom RAL paint finishes
Package Contents Mechanism, IR remote control, Push Flap Kit, Box Enclosure Kit
Marine Suitable Yes
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 2
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
5.9
150
2.052
8.1207
ATo MainsPower
DETAIL A
POWER CABLE
PP
1.538
Maximum Possible Depth of Conduit
TOP VIEW
CABLE ROUTINGThe LSM has an easily removable Mount Cover that cables from the screen can be routed underneath. Cables then travel through the centre of the Mount Boss and into the beam. Cables must be routed carefully to prevent any interference with the LSM beam as it operates.
Screen and Mechanism cables should be routed to a control box outside of the cabinet via an opening in the back of the cabinet or a conduit leading to the bottom.
SCREEN CABLESMECHANISM CABLES
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 3
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
37.4950
InternalCabinetHeight
32.5825
InternalBox Enclosure
Height
0.820
Minimum ScreenHeight fromCabinet Top
Box EnclosureInternal Width =
Screen Width+ 40mm [1.6]
0.820
Max Thicknessof Base andCabinet Top
0.820
0.820
Internal Cabinet Width = Screen Width + 100 [3.9]Minimum Width = 850 [33.4]
B
B
CC 31.5800Max
ScreenHeight
4.2108
Back ofMechanism
to Mount
D
SECTION B-B
0.13
Base Panel toCabinet Aperture
0.820 Minimum Distance
from Screen to inside of CabinetSECTION C-C
Aperture Depth =Screen Depth + 83 [3.25]
(Minimum 121 [4.75])
1.846
DETAIL D
LSM-BE 6 - MECHANISM UP - IN CABINET
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 4
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
37.4950
InternalCabinetHeight
32.5825
Internal BoxEnclosure
Height
5.6142
Minimum ScreenHeight from Base
of Cabinet
0.410
Minimum Distancebetween Box Enclosure
and Cabinet
0.820
E
E 6.3161
31.5800Max
ScreenHeight
4.2108
Back ofCabinet to
Mount
F
SECTION E-E
DETAIL F
Shown with tapered Box EnclosureLid in square Cabinet Aperture.A tapered Cabinet Aperture can beused to improve the fit.
Aperture Width = Screen Width +80mm [3.1]
19.7500
Minimum width of openingin rear face of Box EnclosureAperture Depth =
Screen Depth + 83 [3.25](Minimum 121 [4.75]) G
0.410
Maximum thickness ofBox Enclosure Back Cover
DETAIL G
LSM-BE 6 - MECHANISM DOWN - IN CABINET
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 5
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
2.5
64.50
Base Panel Width = Cabinet Aperture Width -6mm [0.2]
BASE PANEL - TOP VIEW
VIEWING SIDE
Box Enclosure Lid Width = Cabinet Aperture Width -2mm [0.1]
LID (TAPERED) - TOP VIEW
NOTE: A tapered Box Enclosure Lid creates a good fitin the Cabinet Aperture and helps the Box Enclosure tolocate within the cabinet.
Lid Depth =Cabinet Aperture Depth
Depth -2mm [0.1]
Base Depth =Cabinet Aperture Depth
-6mm [0.2](Minimum 115mm [4.4])
BOX ENCLOSURE BASE PANEL AND LID DETAILS
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 6
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
37.4950
InternalCabinetHeight
0.820
Minimum ScreenHeight fromCabinet Top
0.820
Max Thicknessof Base andCabinet Top
Internal Cabinet Width = Screen Width + 100 [3.9]Minimum Width = 850 [33.4]
H
H
II 31.5800Max
ScreenHeight
4.2108
Back ofMechanism
to Mount
J
SECTION H-H
0.820 Minimum Distance
from Screen to inside of CabinetSECTION I-I
Aperture Depth =Screen Depth + 83 [3.25]
(Minimum 121 [4.75])
1.846
DETAIL J
LSM-PF 6 - MECHANISM UP - IN CABINET
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 7
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
37.4950
InternalCabinetHeight
5.6142
Minimum ScreenHeight from Base
of Cabinet
0.820
K
K 6.3161
31.5800Max
ScreenHeight
4.2108
Back ofCabinet to
Mount
SECTION K-K
Aperture Width = Screen Width +80mm [3.1]
Aperture Depth =Screen Depth + 83 [3.25]
(Minimum 121 [4.75])
LSM-PF 6 - MECHANISM DOWN - IN CABINET
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 8
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
1.8
44.50
Base Panel Width = Cabinet Aperture Width - 6mm [0.2]
8076
3.13.0 THRU
BASE PANEL - TOP VIEW
VIEWING SIDE
Base Panel Depth =Cabinet Aperture Depth
-29mm [0.25](Minimum 89mm [3.3]
Push Flap Lid = Cabinet Aperture Width - 6mm [0.2]
L
L
Flap Panel Depth =Cabinet Aperture
-6mm [0.25](Minimum 112mm [4.4]
M
SECTION L-L
0.410
0.12
DETAIL M
A step is required on the front ofthe flap to meet a step in thefront edge of the cabinet aperture
PUSH FLAP BASE PANEL AND LID DETAILS
LID - BOTTOM VIEWVIEWING SIDE
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001
SHEET 9
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
V400
V300
V200
15.7400
11.8300
7.9200
17.3440
Highest PossibleCentreline of Mount
15
.740
0
9.6245
Lowest PossibleCentreline of Mount
15
.740
0
15.7400
CL
SCREEN MOUNT ADJUSTABILITY
CL
A standard adjustable height VESA 400 mount is included. This is alsocompatible with VESA 300 and 200 mounting patterns
Separate VESA 300 and 200 mounts are available.
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001SHEET 10
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
Box Enclosure Top
Box Enclosure Top Support
Box Enclosure Back Section
Box Enclosure Base
The LSM is fixed to the back of thecabinet with wood screws.
Box Enclosure Back Cover
Screen mount must be removedfor installation of Base Panel
The LSM is fixed to the back of thecabinet with wood screws.
The Flap Panel is attachedto a hinge at the back of thecabinet aperture.
Screen mount easilyremoved with concealed bolts
MECHANISM INSTALLATION OVERVIEW
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001SHEET 11
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181
37.4950
19.7501
22.3568
MECHANISM - UP POSITION
37.3948BackTray
Height
6.1154
31.3795
6.5164
OVERALL MECHANISM DIMENSIONS
MECHANISM - DOWN POSITION
WWW.FUTUREAUTOMATION.NET
LSM-BE/PF 6
TECHNICAL SHEETISSUE 001SHEET 12
LIFT SYSTEM FOR BOX ENCLOSURE/PUSH FLAP
UK +44 (0) 1438 833577 US +1 (603) 742 9181