lifa concept consists of - fn-serviss...f7 particle bag filter pre-filter box g3/g4 pre-filter mat...

33
Lifa Air presentation 2018 1 LIFA CONCEPT consists of: criteria for cleaning and results methods for visual evaluation of cleanliness plans for cleaning advanced cleaning machines and techniques quality assurance systems and training materials Ventilation Hygiene Cleaning Machines Vacuum machines Cameras Accesories, brushes etc. Packages

Upload: others

Post on 26-Jan-2021

5 views

Category:

Documents


0 download

TRANSCRIPT

  • Lifa Air presentation 20181

    LIFA CONCEPT consists of:

    • criteria for cleaning and

    results

    • methods for visual

    evaluation of cleanliness

    • plans for cleaning

    • advanced cleaning

    machines and techniques

    • quality assurance

    systems and training

    materials

    Ventilation Hygiene

    Cleaning Machines Vacuum machines CamerasAccesories, brushes

    etc.

    Packages

  • Lifa Air Oy Ltd. • Vellamonkatu 30 B, 00550 Helsinki, Finland • Tel: +358 9 394 858

    Path of the LIFA Cleaning Concept

    Consulting and guidance of customers

    Inspection of need for cleaning

    ”Parallel” photos of Visual scale, robot aided video camera, comb and sampling method

    Selection of cleaning devices:

    Brushing and/ air-jetting machine, brushes+accessories, negative air

    machine, disinfection devices etc

    Verification of the cleanliness, photos of visual scale, camera, etc,

    perhaps not the same as in the first phase

    The first Work document

    a photo of

    dirty duct

    Documentation of the cleanliness,

    Added to the building documents for

    future use

    The second Work document

    a photo of

    clean duct

    document for

    authorities if

    needed

  • Principles of cleaning concept

    Visual inspection

    measurements

    Objective

    Clean

    Acceptable

    cleanliness level

    Cleaning p lan

    Documentation

    No clear conclusion

    Control and maintenance of c leanliness of HVAC systems

    Verification

    Needs to be cleaned

    Cleaning

  • LIFA VENTILATION HYGIENE CONCEPT FOR ROUND AND RECTANGULAR

    AIR DUCTS AND AIR HANDLING UNITS The Concept consists of:

    • criteria for the cleaning and cleaning results

    • methods for the visual evaluation of cleanliness

    • plans for the cleaning

    • optimal choice of the cleaning method

    • advanced cleaning equipment and procedures

    • quality assurance systems and education material

  • Brushing machines, air blowing and liquid

    spreading equipment

    Hydmaster 40 CombiCleaner 40 Special Cleaner 25 Multi

    BIG FRAME

    MACHINES

    FOR DUCTS

    >300MM

    BRUSHING + AIR-JETTING SAME TIME

    SMALL FRAME

    MACHINES

    FOR DUCTS

  • Cleaning machines 2

    • Hydmaster 40: brush rotation by Hydraulic motor, yetoperation power 110/220V electric

    • CombiCleaner 40 + 15: brush rotation bycompressed air motor, separate air hoses for spraying liquid/air-jetting whilst brushing

    • Special Cleaner 25 Multi: brush rotation by electricmotor and cable, separate air hoses for sprayingliquid/air-jetting whilst brushing

    • Special Cleaner 20: brush rotation by electric motorand cable

    • AirJet 20: for spraying liquid or air-jetting (only, no brush) • Special Cleaner 2: brush rotation by electric motor

    and separate cable/shaft, 2-12 meter cables/shaftsavailable

  • Vacuum/air cleaner units – negative air machines

    HepaClean 1100

    AirClean 3500

    HepaClean 2500 HepaClean 4000

  • Vacuum/air cleaner units – negative air machines

  • 3 filters in same unit

    2

    3

    4

    F7 PARTICLE bag filter

    PRE-FILTER BOX

    G3/G4 Pre-filter mat

    HEPA filter

    1

  • Suction power vs. air flow

    • AirClean 3500:

    • air flow 3600 m3/h, suction power 840Pa

    • HepaClean 4000:

    • air flow 4600 m3/h, suction power 1000Pa

    • HepaClean 2500:

    • air flow 2600 m3/h, suction power 840Pa

    • HepaClean 1100:

    • air flow 300-1200 m3/h, suction power 800Pa

  • Video inspection equipment

    -DuctControl Manual: drop cam

    + glass fibre rod on reel, for small

    ducts

    - DuctControl Mini: remote

    controlled driveable camera robot,

    for ducts 16-70cm

    - DuctControl Cleaning Robot:

    compressor powering the brush

    motor, for ducts 20-70cm in

    height

    -New 2011: back camera included

    in both DC Mini and DC

    Cleaaning Robot

  • ACCESSORIES HYDMASTER AND COMBI CLEANER 40

    Y-gear for rectangular ducts >300mm in height – rotating 2 brushes at the same time

    3-brush-gear: for low (100-

    200mm) height but very wide

    (400-1000mm) ducts

  • Brushing machines, robots

    22 kg,

    35cm height

    Up to 1,2m

    Cable length

    30m

    8 kg,

    18cm height

    Up to 70cm

    Width 25cm,

    Cable length

    30m

  • CENTERING DEVICES

    Pneumatic centralizer for

    CombiCleaner 40,

    inflating+deflating remotely

    from switch

    Mechanical one for Hy40, SC25, CC15

    ../../3G Filter/Contacts_Sales/Unitor/info pack 05-2006/CENTERING DEVICES.xls

  • Nozzles included in the price for CombiCleaner

    15 + 40, AirJet Combi 20 and Special Cleaner 25

    Multi:1) disinfectant and liquid spraying (round-small ducts)

    2) air-jetting nozzle (high volume)

    Accessory nozzles

    Foam nozzleY-nozzle (for big

    rectangular ducts)

    Ball nozzle (for small +

    soft surface/flexible ducts

  • Brushes – 2 connection types

    1) M12 screw connection (old type), for driller shafts, SC20

    Soft – hard/stiff – combination=rect ducts – special vs.

    2) Brush adapter connection for brushes with nylon center

  • Comparison of old vs. new type brushes inside duct

    Disk in the center of the brush greatly enhances the speed of vacuum air flow

    Old typeNew type

  • ACCESSORIES FOR VENTILATION CLEANING

    Y-Connection unit for HC2500/4000,

    To combine 2 vacuum units

    Exhaust Hose, clear plastic foil

    700 mm x 0,15 mm, 75 m roll

    Telescope lifting set + flexible duct,

    properly attached into duct

  • Power supply/air compressorsMACHINES THAT OPERATE ON NORMAL 1-PHASE ELECTRICITY

    HYDMASTER 40

    SPECIAL CLEANER 25, 20, 2

    HEPACLEAN 4000, 2500, 1100

    AIRCLEAN 3500, 600

    3-PHASE ELECTRICITY

    AIRCLEAN 7000

    HYDROVANE COMPRESSOR

    MACHINES THAT REQUIRE COMPRESSED AIR

    COMBI CLEANER 40 + 15

    AIRJET COMBI

    SPECIAL CLEANER 25 Multi, only whenspreading liquids or air-jetting withcompressed air

    Hydrovane rotary vane /

    lamell type compressor =

    CONSTANT FLOW AIR

    SUPPLY IS NEEDED (not big

    tank types)

  • Vacuum cleaners

    (dry dust vs grease sludge)

    H-certified always

    preferred; also ”waste air”

    shower upwards)

    picture of washable

    bag filter inside

  • Sprayers for application of coatings and

    disinfectantsFOR AIR DUCTS/PIPES

    Dry-fogging unit for open spaces

    ULV spray unit

    (electric)

    Spray bottle 5l

    (manual) –

    for all LIFA machines

  • Cleaning agents, disinfectants, coatings

    The ULV-technology = Ultra Low Volume is useful for quick disinfecting in the buildings and in ventilation systems.

    There are two basic methods:

    - Dry Fogging with by using Patriot PulsJet Fogger.

    - Damp mist by using MacroMist aerosol aggregat.

    These agents are peroxides.

    For ductwork we are using the "wet aerosol method". The chemical used must be approved by local authorities for HVAC use (formaldehyde and chlorine based chemicals is an absolute no-no), also be aware that some chemicals corrode the duct or kill the the galvanasation.

  • Personal safety, respirators, overalls etc

  • GREASE CLEANING CONCEPT

  • Grease Cleaning Concept

    • suitable for all types of grease, soft or hard-burned and both round and rectangular up to 1,2m in size

    • unique capability of one machine capable of doing brushing, spraying chemicals and adsorbent granules all at the same time.

    • Lifa machines are the only ones powerful and durable enough to be able to rotate a brush in a grease duct is also a decisive factor.

  • Grease Cleaning Concept

    Different methods and techniques• Brushing (grease brush, cloth)

    • Spreading of chemicals and brushing

    • Spreading of oil adsorbent granules and brushing + air-jetting ALL AT THE SAME TIME

    combined in one equipment package:• Effective for all types of grease

    • In all sizes/shapes of ducts

    • Machines can be used in other work also

  • Grease set equipment

    SPREADING SIDE

    Lifa brushing machine: unique

    capability of brushing and air-

    jetting/spraying liquids at the

    same time

    Lifa Granule Sprayer: can be

    attached to CombiCleaner 40,

    Special Cleaner 25 Multi (also

    Hydmaster but then AirJet Combi

    20 is needed too)

    SUCTION SIDE

    Lifa HepaClean machine: unique

    filter options + combination

    capability with superior vacuum

    power

    Lifa Preseparator Unit:

    functionality and money

    savings in less filter change

    needs; attached to HC 2500,

    HC 4000, AC 7000

  • Spreading side: Granule sprayer + Lifa brushing

    machine

    Special Cleaner 25 CombiCleaner 40 + 15 - pneumatic

    Can be attached to

    Hydmaster 40 also Granule Sprayer

  • Spreading side:

    Granule + chemical spraying

    • Hard grease that

    doesn’t come off with

    brushing need to be

    softened with grease

    detergent, foam best

    • Liquidy grease is

    adsorbed into oil

    adsorbent granule,

    then air-jetted and

    brushed out into

    preseparator

  • Nozzles for spraying chemicals and air-jetting

    • BASIC SET (incl. In

    machines): left ”liquid with

    back pressure valve”; right is

    ”high volume air”

    • ”foam nozzle”

    • Y-nozzle small or big with

    bending arms: for air-jetting in

    rectangular ducts

  • Spreading side: brushes for grease cleaning

    • Grease chopper 2 adjustable sizes: with Hydmaster and CC40/15 only, limited use

    • Tynex brush: abrasive ”metal-sand-paper-like”; bristles bend = ”digs” into corners rectangular ducts

    • Metal razor brush:100-400 mm Very sharp ends cuts both solid+sticky grease off. NEEDS TO BE EXACTLY OR SMALLER THAN DUCT !

    • Grease brush with nylon center (hard duct brush): stiff 1,0 mm nylon bristles very hard, little bending = must be exactly or smaller than size of duct

    • Grease brush M12: most ”aggressive” brush; 2,5 mm nylon bristles very stiff, no bending = must be exactly size of duc

  • Suction side: Preseparator (cyclone / gravitational

    filter unit + Lifa negative air machine

    Air flow is simply controlled

    by damper: in minimum when

    spreading granules, max when

    brushing and/or air-jetting

    Removes all heavy and greasy dirt

    before normal filters into a waste bag

    • easily removed and disposed

    • savings in normal filters

  • Filter options

    Prefilter box enables to use 2 different filters at the sametime, any combination: • EU4 (G4) bag filter or filter

    mat• EU7 (F7) bag filter

    • Lifa Fp7 particle and odourbag filter

    • Hepa filter / gas filter