liebert rdu-m br - ap14ent-liebertrdumv1-br...emerson network power provides 24x7 data center...
TRANSCRIPT
Liebert® RDU-MDynamic Environment Monitoring for Secure Data Center Infrastructure
Manage critical equipment activity involving data center power and
thermal management at multiple sites and site monitoring around the
clock. Emerson Network Power provides 24x7 data center infrastructure
management and network monitoring software, hardware, systems and
services to provide continuous oversight and security of data centers,
computer rooms and network closets, as well as applications for different
market verticals.
3
Challenge: Infrastructure Management Need: A solution for centralized management of the entire infrastructure
Challenge: Heat DensityNeed: Environmental Monitoring at Room and Rack Level
Challenge: Power DensityNeed: Effi cient power management tools
Challenge: Accessibility Need: Access type monitoring for rack or data center
Challenge: AvailabilityNeed: Thresholds, event generation and notifi cation capabilities
Mission critical facilities are vulnerable to threats such as excessive heat, power problems, unwanted access, humidity and air impurities to name a few. Data center management doesn’t stop in investing to air and power infrastructure equipments, monitoring plays an integral part of the entire infrastructure. Critical infrastructure monitoring is the key to assuring high availability and maximizing the investments made in these critical facilities.
Infrastructure Challenges
4
System IntegratedSimple installation and automatic system integration of monitoring equipments present in the data center using standard port connections for power, image and video, environment and access & control applications
Real-time MonitoringProvides real-time access and information to environmental, power, cooling and security aspects of the data center and reported via email and SMS
Remote Management Capable of intelligent management of equipments and applications from a remote location
Multi-level monitoring for the entire critical infrastructureProvided room level, rack level and equipment level monitoring
Liebert® RDU-M
Facility Safety Security & Peace of mindSimplified use and
maintenance
Multiple pre-alarm threshold, modes and levels providing preventive alerts to administrators
Full video surveillance of the facility that includes recording, replay and image capture of the facility
Intelligent room and door access functionality issued to authorized IT personnel
Linux operating system; reliable and less frequently affected by virus. Multi-level system management that provides different access levels to different administrators.
Capable of backup and querying of historical data of devices, system operations, alarm notifi cations sent to administrators
User-friendly and customizable graphic interface for a holistic view of the data center
Provides report and analysis of data center and equipment operation including PUE statistics
IP network connectivity, standard network cable connection and web remote access capability
System cloning and critical data backup function for simple and convenient maintenance
The Liebert® RDU-M provides round the clock visibility and holistic monitoring approach to your data center. This infrastructure management platform delivers real time monitoring and dynamic management of the entire IT facility from room, rack and equipment level. The Liebert® RDU-M monitoring software is already installed in a server like hardware appliance that can easily fi t in racks and cabinets. It is also capable of managing multiple monitoring systems, all at the same time, as it easily integrates environmental and security systems placed in the data center. The Liebert® RDU-M best applies from small, medium-sized and cloud-ready data centers and applications.
5
Liebert® RDU-M Models
RDU-MP RDU-MI RDU-MII
Centralized management platform for RDU-A and RDU-SIC
Can manage RDU-A and/or RDU-SIC up to 32 connections Can manage Emerson Door Access systems up to 32 sets
Centralized management platform for RDU-A and RDU-SIC
Can manage RDU-A and/or RDU-SIC up to 128 connections. Door = 64 IP Camera = 64
Centralized management platform for RDU-A and RDU-SIC
Can manage RDU-A and/or RDU-SIC up to 256 connections. Door = 256 IP Camera = 256
Features:
Offers a user-friendly GUI to set up and manage data center infrastructure appliances
Real-time monitoring on environmental, power, cooling, and security in data center
Video surveillance supports video recording/back up/replaying/picture capturing/voice transmission/timed recording and recording action triggered by alarm
Room access control managementRelay actions triggered by alarm or events Alarm notifi cation by Email, SMSReport and analysis on data center / device operation; PUE statistics
6
The Liebert RDU-M provides a holistic view of the infrastructure while monitoring the data center environment and the equipment status in real-time.
7777
3D Capabilities
3D Graphical Image
Critical Alarm
3D Thermal Mapping
Rack Zoom
Collapse
Zoom In
Space Usage
8
Features: High performance and high speed video protocol processor Optimized H.264 video compression algorithm for smooth transmission of the HD image at low bandwidth Built-in Web Server functionality, facilitates the real time monitoring and management setting of the front end of the equipment through standard IE explorer Supports remote system upgrade Connectivity: DNS, LAN and Internet (ADSL, Cable Modem) Supported network protocols: HTTP, TCP/ IP, UDP, STMP, DDNS, DNS, SNTP, DHCP, FTP Supports two-way voice intercom and voice broadcasting Self-adaptive network technology and automatic adjustment of video frame rate according to network bandwidth Alarm functions for video loss and motion detection (confi gurable area and sensitivity) Built-in high-speed dome decoder protocol Video recording / Still image capture Automatic recovery function and connection during network interruption or disturbances Supports up to 32GB of SD 2.0 protocol Installation: Flat or wall mounted
Data Center Video Surveillance & Monitoring System
Hemisphere & Bullet Camera High Sensitivity LCD Automatic white balance tracking and gain control Digital signal processing and CCD aperture
RDU-M
LAN/WAN - TCP/IP
Video Surveillance
Network Video Recorder (NVR)IP Camera twork Video Recorder (NV
Network Video Recorder (NVR)IP Camera Network Video Recorder (NVR
9
Battery Monitoring System
Liebert RDU-M also monitors the state of batteries in real time. It provides battery discharge data, playback and understand the discharge trend.
RDU-A G2
Modbus 485
1. The battery group voltage, resistance, and maximum, minimum, average value of temperature, etc.2. Monitoring of battery state, the alarm information and charge and discharge state.3. Monitoring of battery discharge data, discharge playback, to understand the discharge trend.
Battery Monitoring System
Battery Monitoring System
RDU-M
LAN/WAN - TCP/IP
10
Environment Monitoring System
Alarm Management
Temperature/Humidity SensorsMonitor room temperature and humidity
Smoke SensorsMonitor fi re / smoke in the room or cabinet
Water Stripe SensorDetects water perimeter leakage
IR DetectorA thermographic camera or infrared camera is a device that forms an image using infrared radiation
Alarm Beacon Flashing LED beaconprovides visual exception event notifi cation
LAN/WAN - TCP/IP
Email Phone Alarm SMS(No Voice)
Buzzer Alarm via Contact Closure
Modem
Windows 7 server
m
Buzzer Multimedia SMS Voice
11
Requirements on Client Operating Environment
WEB Browser IE 6.0 or above version
Hardware Configuration Hard disk: 1G and above, memory, 1G and above,
network card, 10MB and above
Network BandwidthOptimizeIT server bandwidth: 10MB and above
Client bandwidth requirement: 10MB and above
Power Supply
AC power supply equipment (each power supply equipment)
RDU-MP 350W, Auto Ranging(100 – 240 VAC, 50/60 Hz).
RDU-MI 350W, Auto Ranging(100 – 240 VAC, 50/60 Hz)
RDU-MII Redundant power infeed, 350W x 2, Auto Ranging
(100 – 240 VAC, 50/60 Hz).
Voltage 100-240VAC, 50/60Hz
Maximum Surge CurrentUnder the typical circuit condition and within the operating range of the
overall system environment, the surge current of every power equipment is likely to reach 25A within 10millisecond or even a shorter time.
Liebert®
RDU-M Hardware Technical Specifications
Category RDU-MP RDU-MI RDU-MII
Weight 8Kg 8Kg 15Kg
Dimension 42.6 x 431 x 393.7 (mm) 42.6 x 431 x 393.7 (mm) 42.9 x 434.0 x 612.6 (mm)
1.67” x 17.1” x 15.5” 1.67” x 17.1” x 15.5” 1.69” x 17.10” x 24.12”
(with mounting bracket and bezel)
RDU Integration 2-layers 2-layers 3-layers
RDU RDU-A, RDU-SIC RDU-A, RDU-SICRDU-MII/MI/MP, RDU-A, RDU-SIC
Quantity allowed <=32 (IP Address) <=128 (IP Address)<=256 (IP Address)and <=16 RDU-M
Video Surveillance
Camera Type Not Available IP Camera (Dome/Box) IP Camera (Dome/Box)
Quantity allowed None <=64 (IP Address) <=256 (IP Address)
Quantity of door access controller allowed
<=32 <=64 <=256
12
The Liebert® RDU-A G2 is an infrastructure management solution from Emerson Network Power that allows data center administrators to manage environmental conditions i.e. temperature and humidity, leak, smoke, vibrations and digital inputs and outputs. It is also capable of monitoring infrastructure appliances such as UPS, precision cooling units, generator sets and etc. The Liebert® RDU-A G2 is equipped with a built-in web server, eliminating the need to perform a software installation.
Liebert®
RDU-A G2
The Liebert® RDU-A G2 allows data center managers to perform the following operations through a secure web page:
Monitoring of the health and status of the equipment Monitoring of environmental conditions i.e. temperature and humidity, leak and smoke. Improved communication speed in transmitting control or commands to the equipment and parameter setting Data and logs of historical information of alarms and notifi cations
3rd Party Communications: SNMP Modbus 485 Dry contacts
The Liebert® RDU-A G2 serves as the communication gateway for the equipment and the Liebert® RDU-M solution. It intelligently collects and communicates data and commands, giving IT administrators a comprehensive view of what’s happening at the equipment level of the facility.
FRONT
BACK
Mechanical SpecificationsExternal model Measurement Valve Error
IRM-HOST2
Height 43mm <±0.5 mmWidth 440mm <±1 mm
Depth 311mm <±1 mm
Weight <8kg
IRM-4COMIRM-8DIAI
IRM-8DOAO
Height 20mm <±0.5 mm
Width 158mm <±1 mm
Depth 199mm <±1 mm
Weight <1kg
Environment Conditions Item Requirement
Application location Usually in data center or computer room, with air conditioner
Working temperature -10ºC ~ +60ºC
Relative humidity 5%RH ~ 95%RH, no condensing
Working environment Dust: compliant with the indoor requirements of GR-63. No corrosive gas, fl ammable gas, oily mist, steam,
water drops or salt
Air pressure 70kpa ~ 106kpa
Storage temperature -40ºC ~ +70ºC
Cooling Natural cooling
Power distribution network TT/TN
Protection level IP20
13
Access Control System
The access control system of the Liebert RDU-M primarily provides security and prevention of unauthorized access or entry to the data center facility. The hardware components of this access control system is based on leading international facility security designs that is also equipped with high adaptability to monitoring systems, clock technology, surge and lightning protection design, anti-interference and anti-static designs.
Access Control BoxDimensions: (L×W×H): 380mm×200mm×69.5mmMaximum
ConnectionDistance:
1200m
Display:6-digit red LED, displaying numbers or simple Englishcharacters
Lock Driving Interface:
NO/NC contacts
Contact Capacity: DC12V/2A/25Sec, DC24V/2A/25Sec, AC75V/3A/25Sec
Card Reader Port:
Wigan Signal Input Effective Low Level (or OC Door Conduction): -0.7V- +0.7V, IOUT MAX =8mA Wigan Signal Input Effective High Level (or OC Door Shut-off): high resistance -+4.0V, IOUTMAX=0mA Wigan 26BIT, 34BIT,Wigan Signal Input Effective High Level (or OC Door Shut-off): high resistance -+4.0V, IOUTMAX=0mA Wigan 26BIT, 34BIT, 36BIT and 44BIT card
numberautomatic identifi cation
Operating Temperature:
-10oC~50oC
Storage Temperature:
-30oC ~70oC
Humidity: 5% ~ 95%RH (no condensation)
Fingerprint ReaderDimension: 155mm(L) * 52mm(W) * 39mm(D) ±5%Weight: 0.2Kg±5%Working Voltage: 12VDC±5%Working Current: 300mA±5%Car Type: ID or IC cardFrequency: ID card: 125KHZ±5% IC card: 13.56MHZ±5%Reading distance: 50-100mm (without other same products interferences)Working
environment: -10~+55º C degree,
20%~90%-20~+70ºC, 5%~90%
ESD parameter: air discharge ±8KV
14
Electrical LocksetRated OperatingVoltage:
12V DC
Input Voltage Range: 10.8VDC-13.2VDCOperating Current: Single-opened: 0.48AMinimum Supply Current:
Single-Opened: at 800mA/12V DC input
Rated Power: single-opened: ≤6.2WRated Pulling Force: Single-Opened: 270Kg±5KgDoor Open Mode: 90o
Operating Environment:
Temperature: 10oC ~ +50oCHumidity: 20% ~ 90% (no condensation)
Applicable Door Type:
Applicable to wood door, glass door without bottom frame
(with U support) and fi reproof door
Outside ButtonModel: EP67Maximum Switch Current:
48VDC, 2A
Operating Temperature:
-25oC ~ -105oC
Button Material: Brass with nickel platingPanel Material: Stainless steelMechanical Life: 1,000,000 timesProjecting Button
Size:¢ 22×2mm
Pane Size: 86×86×6mm
RDU-M
RDU-A G2
RS 485 Controller
Exit Button Card Reader
LockLock
Dual Swing Glass Door
Finger print / Card + Password
Access Management
LAN/WAN - TCP/IP
15
Device Management
Energy Management
1. Device status monitoring (PUE, Teamwork)2. Device Control and monitoring3. Individual monitoring interface for each device.
PUE Model PowerCalculate by the monitoring the power meter.
PUE Model EnergyCalculate by the direct reading of UPS power. Can also be computed by manual entry results
LAN/WAN - TCP/IP
Metered PDU
UPS, Cooling, etc.
Server, switch, etc.Light, camera, etc.
Power Meter
Power Meter
LAN/WAN - TCP/IP
OS Type1. Windows
LAN/WAN - TCP/IP
Based on Java Script, CSS, HTMLMobile
16
Applications: Small Computer Rooms
How much do you need to manage in small computer rooms / Data Centers?With this solution, top management monitoring platform is easy to achieve with user friendly graphics and confi gurations.
RDU-M
RDU-A G2
Infrastructure AppliancesInfrastructure Appliances
LAN/WAN - TCP/IP
17
Expanding your data center?With this solution, scaling to adapt to your current changes is manageable and easy to maintain.
RDU-M
RDU-A G2
RDU-A G2
Security and Infrastructure AppliancesSecurity and Infrastructu
Applications: Medium Sized Data Centers
LAN/WAN - TCP/IP
18
Cloud Ready?Data Centers on cloud need not to be expensive in terms of management. Scalability with security is the key.
MAIN NOC
Site B
Site C
Site D
Applications: Enterprise and Cloud Ready Data Centers
LAN/WAN - TCP/IP
19
Make your Data Center as Dynamic as Your Business
Change the way your data centers are managed—your top priority todayAn imperative to improving performance and controlling costs
� Power switching and controls for emergency, critical, standby and distributed power� Critical power management systems used locally or remotely� Load banks up to 15K for generator and UPS testing or exercising� Surge Protection Devices (SPD) for commercial and critical power markets� Related services include maintenance, commissioning, product upgrades and reliability assessments
POWER SWITCHING & CONTROLS
SERVICES
� Complete life-cycle approach from project launch to ongoing maintenance performance optimization� Largest service footprint in the industry: 945+ Service Field Engineers, 95+ Service Centres, 75+ Technical Support/Response in Asia Pacific� Project Management, Equipment Maintenance and Performance Optimization capabilities
� Easy to deploy solution for high density requirements� Provides the components of a high availability enterprise data centre into an enclosed aisle of racks� Integrated DCIM capabilities for building and IT facilities management and capacity planning� Visibility of critical infrastructure life signs in a local office, equipped with power protection solution suitable for remote locations or across a distributed network
� Fast and efficient deployment, anytime, anywhere� Pre-assembled and factory tested to ensure quality and reliability� Fully integrated power and climate systems� Custom designs available to meet individual site needs � Wide variety of applications: oil & gas, mining, military, telecom, data centres
MODULAR CONTAINERIZEDDATA CENTRE� Industry-tested power protection and back-up power solutions
� Uninterruptible Power Supplies: Desktop, Rack and Row based, Room and Site-based� Power Distribution Units: Room-based with metering & voltage transformation, Rack mountable with metering & management capabilities
AC POWER
� Industry’s most efficient and reliable management of heat� Achieve industry leading efficiency levels (PUE <1.1)� Complete line of energy efficient, and reliable technology solutions � Data centre controls and service to optimize efficiency and uptime
THERMAL MANAGEMENT
� Best-in-class DC Power Solutions adapted by major telecom providers around the globe� Modular system architecture minimizes capital investment while allowing future growth� Increased intelligence to match utilization to capacity� Streamlined technology that reduces failure points and ensures high reliability
ENERGY SYSTEMS
� Real-time, data centre optimization platform � Inventory management and site management and monitoring� Change planning� Energy Insight, Power Management and Thermal Management
DATA CENTRE INFRASTRUCTUREMANAGEMENT
It has never been more diffi cult to manage a data center. The demand for services, environmental complexity and criticality of availability is at an all-time high.
Add to those factors a constant pressure to control costs, and it is easy to understand why organizations are rethinking how they run the data center.
By implementing the right combination of hardware and software solutions to manage the data center infrastructure, you can:
Reduce day-to-day costs and time involved in operating and maintaining the data center
Enable better management decisions by getting the right information to the right people at the right time
Make better use of existing IT and infrastructure resources, optimize data center performance and improve system availability
Emerson Network Power is the trusted source for innovative solutions and expertise in power and precision cooling systems, integrated racks andenclosures, power switching and controls, monitoring and connectivity. With our Liebert®, Avocent and Aperture® brands, we’ve been delivering data center infrastructure management benefi ts for years.
While every precaution has been taken to ensure accuracy and completeness herein, Emerson Network Power assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifi cations are subject to change without notice.
Emerson Network Power and Liebert® are trademarks of Emerson Electric Co. or one of its affi liated companies. All other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. ©2014 Emerson Electric Co.
Emerson Network Power Asia
PakistanT: 92-42-36622526 to 28F: 92-42-36622530
PhilippinesT: 63-2-7207400 F: 63-2-6203693
SingaporeT: 65-64672211F: 65-64670130
ThailandT: 66-2-6178260F: 66-2-6178277 to 78
VietnamT: 84-4-37628908F: 84-4-37628909
AustraliaT: 1800-065345F: 61-2-97438737
IndonesiaT: 62-21-2513003F: 62-21-2510622
JapanT: 81-3-54038564F: 81-3-54032919
KoreaT: 82-2-34831500F: 82-2-5927886
MalaysiaT: 603-78845000F: 603-78845188
New ZealandT: 64-3-3392060F: 64-3-3392063
www.EmersonNetworkPower.Asia
AP14ENT-Liebert®RDUMV2-BR