    t e C H N I C A L S H e e t

    LG00050-b-UK

    Description

    The special SCS control, with two module, lush-mounting and lowered, is itted with4 pushbuttons and two green/red two-colour LEDs. The LEDs may be adjusted orexcluded using the pushbutton on the control.The control can be used or perorming both standard and special unctions (timedON, scenario control, timer control, dimmer, unctions or video door entry system andsound system).

    Technical data

    Power supply rom SCS BUS: 18 27 VdcAbsorption in stand-by: 7.5 mAOperating temperature: 5 35 C

    Special control

    Legend

    LED1.

    Upper pushbutton2.

    Lower pushbutton3.

    Pushbutton or LED adjustment/exclusion4.

    LED5.Conigurator housing6.

    BUS7.

    7

    6

    5

    2

    3

    4

    1

    5739 87

    Dimensional data

    Size: 2 lush-mounting lowered modulesDepth: 15.5 mm

  • 7/29/2019 LG00050_b_UK

    2/62

    LG00050-b-UK

    Mode with SPE=0 - automation standard functions - Automation

    Possible function M configurator value

    Cyclic control. For point-point controls, the ON/OFF unctions are perormed by a quick pressure, while a longer pressure will beused or the adjustments; or the other controls only the ON/OFF unctions are perormed

    No congurator

    ON control only ON

    OFF control only OFF

    On control using the upper key, O control using the lower key. For point-point controls, the ON/OFF unctions are perormed by aquick pressure, while a longer pressure will be used or the adjustments

    0/1

    Control o rolling shutter up-down to end o stroke hi

    Control o monostablerolling shutter up-down (duration o the control or the whole time the key is pressed) hi M hi

    Pushbutton mode PUL

    Timed ON control 1) 1 8

    The control, which address is indicated in A and PL, sends a control or the scenario programmer, 035 65 2) CEN

    1) The device puts the actuator which it has in address in OFF ater a time laid down by the congurators used, as indicated in the table

    2) Enabling o keys T1 (upper) and T2 (lower) or the management o programmer 035 65 scenarios.

    Configurator Time (minutes)

    1 1

    2 2

    3 3

    4 4

    5 5

    6 15

    7 30 seconds

    8 0.5 seconds

    5739 87

    The advanced control may also be used in systems with SCS/SCS gateway (035 62).If the control is installed on the Bus of an interface, it will be possible to directlycontrol the actuator on the Bus of another interface, without the need for intermediateauxiliary controls. For this, the I configurator, representing the interface address onwhich Bus is the actuator to control, must be used. The logic expansion interfaces onthe system must be numbered from 1 to 9. When I=0, the device on the local line iscontrolled, while if I=CEN, the device controlled is the one installed on the riser. Withthe new control, it is therefore possible to set addresses for 81x9 devices connectedto the buses for the 9 interfaces + 81 devices in the riser, for a total of 810 addresses.

    The M, LIV1 and LIV2 housings are also used for timer control functions.

    Configuration

    A: RoomPL/PF: Light point/voice point (sound system)M: ModeLIV1/AUX: Dimmer 1 level (with SPE=5 9), or AUX channel (with SPE=rom 0 4

    and rom 6 8)LIV2: Dimmer 2 level (with SPE=5 9)SPE: SpecialI: Address o the devices to be controlled

  • 7/29/2019 LG00050_b_UK

    3/6

    SCS

    BUS

    S

    yStem

    3

    t e C H N I C A L S H e e t

    LG00050-b-UK

    Mode with SPE=1 Advanced functions Automation

    Possible function M configurator value

    Locks the status o the devices to which the control is addressed 1

    Unlocks the status o the devices to which the control is addressed 2

    Unlocks with upper key, and locks with lower key 3

    ON short timed 2 seconds 7

    ON timed 10 minutes 8

    Mode with SPE=2 - Flashing Automation

    Possible function M configurator value

    On with fash 1) 0 9

    1) When an actuator receives a fashing control, this is perormed closingand opening the relay or a time equal to T. The T time depends on thecongurators used in M, as shown in the table:

    Configurator Time (seconds)

    0 0.5

    1 1

    2 1.5

    3 2

    4 2.5

    5 3

    6 3.5

    7 4

    8 4.5

    9 5

    Mode with SPE=3 - dimmer level Automation

    Possible function M configurator value

    Selection o the adjustment level o Dimmer 1) 1 9

    1) The M congurator denes the adjustment in % o the power o the load,as shown on the table Configurator %P on the load

    1 10

    2 20

    3 30

    4 40

    5 50

    6 60

    7 70

    8 80

    9 90

    5739 87

    T T

  • 7/29/2019 LG00050_b_UK

    4/64

    LG00050-b-UK

    Mode with SPE=5 - advanced dimmer functions, cyclic version - Automation

    Possible function M configurator value

    Selection o the SOFT-START and SOFT-STOP speed (see table below) and selection o the xed adjustment level rom 1% to 99%

    through the LIV1=0 9 and LIV2=0 9 housings. Control is cyclic with ON at the selected level, and OFF. I LIV1=LIV2=0, thecontrol enables to switch between ON (at the last saved level) and OFF, with a quick pressure. For point-point controls, adjustmentis perormed with an extended adjustment. The unction is only active i the device address corresponds to a dimmer actuator.

    0 9

    Configurator Soft-start and soft-stop time (seconds)

    0 Deault

    1 1

    2 3

    3 5

    4 10

    5 20

    6 407 1 minute

    8 2 minutes

    9 4 minutes 15 seconds

    Mode with SPE=6 - scenario control - Automation

    M configurator value Key 1 (T1) Key 2 (T2) Key 3 (T3) Key 4 (T4)

    1 scenario 1 scenario 2 scenario 3 scenario 4

    2 scenario 5 scenario 6 scenario 7 scenario 8

    3 scenario 9 scenario 10 scenario 11 scenario 12

    4 scenario 13 scenario 14 scenario 15 scenario 16

    NOTE: M=1 4 identies the group o the scenarios to control with the our keys, T1, T2, T3 and T4.

    The special control does not manage the scenarios by saving them in its own memory,but has the unction o recalling, creating or changing 4 scenarios in the scenarioModule 035 51.

    The A and PL positions o the special control must correspond to those o the scenariomodule, while the association o each key o the control with one o the scenariossaved, is perormed by coniguring the M housing

    5739 87

    Mode with SPE=4 - scenario repetition - Automation

    Possible function M configurator value

    Repetition o scenario 1 9 o the scenario module which address is specied in A and PL 1 9

  • 7/29/2019 LG00050_b_UK

    5/6

    SCS

    BUS

    S

    yStem

    5

    t e C H N I C A L S H e e t

    LG00050-b-UK

    Scenario programming:

    To program, change or delete a scenario, the programming of Module 031 51 must beenabled, confirmed by the programming status LED turning green (press the lock/unlockkey of the scenario module for at least 0.5 seconds). After this has been done proceed asfollow:1) Press one o the our special control keys the scenario should be associated to or

    3 seconds. The corresponding LED starts lashing.2) Set the scenario using the corresponding controls or the various Automation,

    Temperature control, Sound system, etc. unctions.3) Conirm the scenario by quickly pressing the corresponding key on the special

    control to exit programming mode.4) To change a scenario or create new ones to combine with other pushbuttons,

    repeat the procedure starting rom 1.To recall an existing scenario, a quick pressure o the corresponding key is enough. Tocompletely delete a scenario, press the corresponding key or 10 seconds.

    Mode with SPE=7 - video door entry system mode video door entry system

    Possible function M configurator value

    Door lock control; A and PL are the address (two digits) o the entrance panel or which to control the door lock using the T3key (bottom let); the T4 key (bottom right) the one o entrance panel EP (A/PL)+2, the T1 key (top let) controls the door lock oentrance panel EP (A/PL)+1 and the T2 key (top right) the one o entrance panel EP (A/PL)+3.

    1

    Control or call to the foor; A and PL are the address (two digits) o the handset to call. 2

    Control to switch on the staircase lights; A and PL are the address (two digits) o the handset rom where the staircase lights arecontrolled.

    3

    Keys to manage the scenarios

    Key 2

    Key 4

    Key 1

    Key 3

    This mode is used to control the amplifiers and the sources of the Sound System.By appropriately configuring A, PL/PF and M, the following functions can be obtained:1) A = 1 9 address of the room of the amplifier to control

    PL/PF = 0 9 address of the amplifier to controlM = 0 (Follow-me mode)*2) A=AMB room configuration

    PL/PF = 0 9 configuration of the room to control (in this case all amplifiers of thesame room will be controlled)M = 1 (sound source activation S = 1)*

    3) A = GEN this mode allows activation of all amplifiers within the homePL/PF = M = 4 (activation of sound source S = 4)*

    NOTE (*):M = 1 4 indicates the sound source to activate before switching the amplifier onIf M = 0, source 1 is activated without first switching all sources OFF (follow-me mode)

    With all SPE = 8 modes, LIV1, LIV2 and I sources must not be configuredExample:I A=1, PL/PF=1 and M=3, the radio control will manage the ampliier with address

    A=1 and PF=1, and will activate source 3.In sound system mode, the special control keys perorm the ollowing unctions:1) the ollowing sequence is sent by briely pressing T1:

    - Sources ON: source 1 is switched on only i M=0;- Ampliier ON

    2) With an extended pressure o T1- or point to point controls, i the ampliier is already on, only the volume is

    adjusted (VOL+); i the ampliier is o, the irst switch-on sequence is sent;- For Room, Group and General controls, only the volume is adjusted.

    3) With extended pressure o T3, the volume (VOL) is adjusted. A quick pressure willsend the O control to the ampliier.

    4) Press T2 to change the source,5) T4 is the active source control.

    Mode with SPE=8 - sound system mode

    5739 87

    NOTE: The picture is provided as a reerence only, the position o the keys is thesame or all Legrand house automation series.

  • 7/29/2019 LG00050_b_UK

    6/66

    LG00050-b-UK

    The conigurator in AUX indicates the auxiliary channel number which activates the control. On receiving a message sent on the AUX channel indicated, the device sends thecontrol or which it is conigured, as i its own control pushbutton had been pressed.

    Management of input auxiliaries (AUX)

    Mode with SPE=9 - advanced dimmer functions, O/I version

    Possible function M configurator value

    Selection o the SOFT-START and SOFT-STOP speed (see table below) and selection o the xed adjustment level rom 1% to 99%through the LIV1=0 9 and LIV2=0 9 housings, according to the table or SPE=5. Control is ON at the level selected with theupper key and OFF at the one selected with the lower key. I LIV1=LIV2=0, a quick pressure o the upper key will be enough orthe ON control (at the last level saved), and o the lower key, or the OFF control; only in case o point-point controls, an extendedpressure will give the possibility to perorm adjustments (upwards with the upper key and downward with the lower key), on 100levels at variable speed.

    0 9

    In this mode the control only works as a timer. In order to use this special control asa timer control, the meaning o the conigurators is as ollows:M becomes M1LIV1 becomes M2LIV2 becomes SConigure the housings M1 and M2 or setting the timer minutes, and S or the timerseconds, in 5 sec. steps; see table.

    I M1=M2=S=9, a control is sent with a 0.5 sec. time value. I M1=M2=S=0, thecontrol is not timed and works in cyclic ON-OFF on the bottom let pushbutton. Bycorrectly selecting the sub keys, it is possible to only send timer controls or, usingthe two right keys, the usual ON, OFF or dimmer adjustment controls.

    Mode with SPE=ON - timer control

    Configurator Time (seconds)

    0 0

    1 5

    2 10

    3 15

    4 20

    5 25

    6 30

    7 358 40

    9 45

    5739 87

    DEFAULT

    100%

    0%

    30%

    60%

    PUSH t > 2 s

    LED adjustment