For continual product development, LG reserves the right to change specifications without notice. LG Electronics Inc. Printed in Korea 2009
LG Electronics Air Conditioning Marketing 20 Yeouido-dong, Yeongdeungpo-gu, Seoul 150-721, Korea Phone: 82-2-3777-1114 E-Mail : [email protected] http://www.lge.com
LG AIR CONDITIONINGWe always pursue highly advanced technologies to improve the quality of your life. Enjoy a clean, quiet & comfortable life with LG Air Conditioners.
ME-CA091
w w w. l g e a i rc o n . c o m
Contents
06
14
20
LG Electronics, The Worlds Best SellerCeiling Concealed Duct Type Single Packaged Type Ducted Split Type
24
36
Fan Coil Unit
MULTI M & M DX
Models Line upBtu/hCeiling Concealed Duct Type
The Worlds Number 1 Choice in Air Conditioners!
7,000
9,000
12,000
18,000
22,000
24,000
26,000
30,000
36,000
42,000
48,000
60,000
72,000
80,000
100,000
150,000
Fan Coil Unit Type
Single Packaged Type
Ducted Split Type
3~6tons* The exact appearance of products may vary from the images shown here.
3~6tons
7.5~30tons
3~5tons
7.5~12.5tons
15~20tons
Btu/h
7,000
9,000
12,000
18,000
22,000 18,000
24,000
26,000
30,000
36,000
42,000
48,000
60,000
72,000
80,000
100,000
150,000
Single Split Wall Mounted Type
Ceiling Cassette Type
Floor Standing Type
Ceiling and Floor Type
Ceiling Suspended Type
LG AIR CONDITIONERS 2009
Ceiling Concealed Duct Type
*E.S.P: External Static PressureThe air volume and sound level is kept constant as designed regardless of changes in E.S.P.(External Static Pressure) E.S.P. technology - Optimizes Duct Installation - Keeps Capacity & Sound Levels within desired ranges - Reduces the number of models Phase control motor technology reduces installation costs. The desired air flow is obtained by adjusting the phase motor during installation of the product, giving you more flexibility when setting up your duct system. The E.S.P can be adjusted linearly from 0 to 10mmAq.
PLASMA Air Purifying System (Accessory)The integrated PLASMA Air Purifying System removes microscopic contaminants and dust, eliminates offensive odors and prevents allergic reactions. It can also be used as an airpurifying unit only, without running the air conditioner.
Ceiling Concealed Duct TypeHidden in the ceiling, this model is designed for buildings that require floor level air conditioning for many individual rooms or large areas, like restaurants, concert halls and hotels. Installation is not restricted by lighting fixtures or the building layout, and interior renovation is made easy by installing ventilation diffusers.
Evaluated by CSIRO Australia (DBCE Doc 98/204) Tested by Korean Food Research Institute and Japanese Environmental Centre and Yonsei Univ. College of Medicine. (Allergy Research Lab.)
Ceiling Concealed Duct Type
Dust ReductionRespirable particles from 5 cigarettes in a sealed room removed by the LG Plasma Air Purifying System.
06 07
DeodorizationLG's Plasma Air Purifying unit effectively removes high concentrations of tobacco odors (Confirmed in sensory tests carried out in Korea and Japan.)
Anti-AllergyIn clinical tests, the LG Plasma Air Purifying System reached a satisfaction level of 82% .
LG AIR CONDITIONERS 2009
LG AIR CONDITIONERS 2009
Ceiling Concealed Duct Type
Ceiling Concealed Duct Type
Long Distance Piping High ElevationLG Air Conditioners (Cassette and Duct-type models) can be installed at long distances (max 50m) and high height differences (30m) from the outdoor unit.
Timer-controlled OperationIf desired, you can set operation times for up to one week in advance.
Zone Controller (Accessory)1) Basic Operation - With a temperature sensor controlling every diffuser, the temperature for each zone can be monitored and adjusted automatically. 2) Control Features - If every damper is closed, the compressor and outer fan are turned off, to protect the compressor.
Central Controller (Accessory)1) Basic Operation - Linking several units, one Central Control Unit can manage and turn off several units individually or as a group. 2) Control Features - Each indoor unit is connected to a Central Control Unit via a data communication cable and can be operated or turned off individually or together with a group of units with the central controller. - The Central Control Unit can manage up to 8 * 16 indoor units.
Plz refer to the picture below.
Option Wireless Remote controller
50m
30m
Ceiling Concealed Duct Type
LCD Wired Remote Controller 24-Hour ON/ OFF Timer with 1 hour intervals TEST RUN Mode Self-Diagnosis feature 3-Step Fan Speed selection Operation Indicator Room Temperature Display Only 20mm thick Zone D Zone A Zone B Zone C
Auto ChangeoverNeed not control on each times at big diurnal range areas.
High Head Drain Pump (Accessory)08The High Head Drain Pump pumps water up to 700mm high for smooth drainage.
09
Zero standby power consumption- Eliminates waste of electricity in standby mode. - Electricity is wasted when an appliance is connected to an outlet, even though the appliance is turned off. - Development of a super power-saving SMPS (Swiching Mode Power Supply) - Minimal standby power consumption (90% reduction of standby power). - No need to pull the main power plug when the appliance is not in use.
Target TemperatureMicro Processor
HeatingAnalyze 3 Temperature
Outdoor Temperature Indoor Temperature
Dehumidifying Cooling
Measure Periodically
1
2
16
1
2
16
Pipe fixture
Wall
1 5 9 13
2 6 10 14 On
3 7 11 15
4 8 12 16 Off
1 5
2 6 10 14 On
3 7 11 15
4 8 12 16 Off
1 5
2 6 10 14 On
3 7 11 15
4 8 12 16 Off
Two Thermistor ControlThe dual thermistor control regulates the difference between the indoor temperature and the temperature of the conditioned air by monitoring both temperatures, to ensure a uniform room temperature. The sensor readings are adjusted for optimum room temperature.
700mm
Controller #1
9 13
Controller #2
9 13
Controller #8
Flexible Drain Hose Drain pump Drain pipe
LG AIR CONDITIONERS 2009
Ceiling Concealed Duct Type
Ceiling Concealed Duct Type
LB-C186HSS1 LB-C246HSS1Group Control1) Basic Operation - Linking several units, one Group Control Unit can manage a number of indoor units. 2) Control Features - Through a data cable connected to each indoor unit, a group of units can be managed from the group controller. - The Group Control function is enabled by cutting an optional jump wire in the wired remote control, which prevents data collision. - One Group Control Unit can control up to 16 indoor units.
TB-H186HSS0 TB-H246HSS0
Gold Fin Anti CorrosionLGs Outdoor Heat Exchanger is coated with a gold-colored anti-corrosive epoxy treatment on the aluminum coil, to prevent corrosion. This maintainsexcellent heat transfer properties of the coil for an extended time, whereas non-Gold Fin coils progressively lose efficiency due to surface corrosion. Gold Fin fin is perfect for areas with high pollution or locations exposed to saltwater spray from the sea.
Features Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)
Salt Spray Test for 15 DaysGold Coated Aluminum Uncoated Aluminum
After 15 Days
After 15 Days
SpecificationLG Gold Fin Corrosion Free Conventional Starting to corrode
ModelCapacity Cooling Heating Electrical Data Power Supply Power Input Running Current Performance EER COP Air Circulation Cooling Heating Indoor(H/M/L) Btu/hr.W W/W CMM l /hr Indoor(H/M/L) Outdoor Max External Static Pressure Cable Main dB(A)3 dB(A)3 mmAq No.*(mm2)*Max L.(m) Cooling / Heating Cooling / Heating ,V,Hz W A Btu/hr Btu/hr
LB-C186HSS118,000 1, 220~240,50 2,020 / 9.5 / 8.91 16/14.5/13 1.5 36/34/32 55 6 3*2.5 4*0.75*220 880*260*450 870*655*320 35/55 52/107 6.35/15.88
TB-H186HSS018,000 18,000 1, 220~240,50 2,020 / 2,020 9.5 / 9.5 8.91 2.90 16/14.5/13 1.5 36/34/32 55 6 3*2.5 5*0.75*220 880*260*450 870*655*320 35/55 52/107 6.35/15.88
LB-C246HSS124,000 1, 220~240,50 2,750 / 12 / 8.73 18/16.5/14 2.7 37/35/33 55 6 3*2.5 4*0.75*220 880*260*450 870*800*320 35/60 44/85 6.35/15.88
TB-H246HSS024,000 24,000 1, 220~240,50 2,700 / 2,700 12.0 / 12.0 8.89 2.61 18/16.5/14 2.7 37/35/33 55 6 3*2.5 5*0.75*220 880*260*450 870*800*320 35/60 44/85 6.35/15.88
2
........
16
Moisture Removal Noise Level
........
Conneting No.*(mm2)*Max L.(m) Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Service Valve Indoor Outdoor Indoor/Outdoor Without S/Parts Liquid/Gas mm mm Kg 20/40ft (mm)
Note :Due to our policy of innovation some specifications may be changed without notification.
10
11
Ceiling Concealed Duct Type
Ceiling Concealed Duct Type
LB-C306GSS1 LB-C366GSS1
TB-H306GSS0 TB-H366GSS0
LB-C368GSS1 LB-C428GSS1
TB-H368GSS0 TB-H428GSS0
Features Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)
Features Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)
SpecificationModelCapacity Cooling Heating Electrical Data Power Supply Power Input Running Current Performance EER COP Air Circulation Moisture Removal Noise Level Indoor(H/M/L) Outdoor Max External Static Pressure Cable Main Cooling Heating Indoor(H/M/L) Btu/hr.W W/W CMM l /hr dB(A)3 dB(A)3 mmAq No.*(mm2)*Max L.(m) Cooling / Heating Cooling / Heating ,V,Hz W A Btu/hr Btu/hr
SpecificationLB-C306GSS130,000 1, 220~240,50 3,600 / 17.0 / 8.33 28/26/24 3 43/42/40 56 8 3*3.5 4*0.75*220 1,180x298x450 870x800x320 38/65 31/69 6.35/15.88
TB-H306GSS030,000 30,000 1, 220~240,50 3,400 / 3,400 15 / 15 8.82 2.59 28/26/24 3 43/42/40 56 8 3*3.5 5*0.75*220 1,180x298x450 870x800x320 38/65 31/69 6.35/15.88
LB-C366GSS136,000 1, 220~240,50 4,100 / 18.8 / 8.78 32/29/26.5 3.5 43/42/40 58 8 3*5.5 4*0.75*220 1,180x298x450 870x800x320 38/70 31/69 9.52/15.88
TB-H366GSS036,000 36,000 1, 220~240,50 4,100 / 4,100 18.8 / 18.8 8.78 2.57 32/29/26.5 3.5 43/42/40 58 8 3*5.5 5*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 6.35/15.88
ModelCapacity Cooling Heating Electrical Data Power Supply Power Input Running Current Performance EER COP Air Circulation Moisture Removal Noise Level Indoor(H/M/L) Outdoor Max External Static Pressure Cable Main Cooling Heating Indoor(H/M/L) Btu/hr.W W/W CMM l /hr dB(A)3 dB(A)3 mmAq No.*(mm2)*Max L.(m) Cooling / Heating Cooling / Heating ,V,Hz W A Btu/hr Btu/hr
LB-C368GSS136,000 3, 380~415, 50 4,100 / 6.3 / 8.78 32/29/26.5 3.5 43/42/40 58 8 5*2.5 4*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 6.35/15.88
TB-H368GSS036,000 36,000 3, 380~415, 50 4,100 / 4,100 6.3 / 6.3 8.78 2.57 32/29/26.5 3.5 43/42/40 58 8 5*2.5 5*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 6.35/15.88
LB-C428GSS142,000 3, 380~415, 50 5,000 / 7.8 / 8.40 32/29/26.5 4.5 43/42/40 59 8 5*2.5 4*0.75*220 1,180x298x450 870x1,038x320 38/78 30/63 9.52/19.05
TB-H428GSS042,000 42,000 3, 380~415, 50 5,100 / 5,400 8 / 8.5 8.24 2.41 32/29/26.5 4.5 43/42/40 59 8 5*2.5 5*0.75*220 1,180x298x450 900x1,165x370 38/95 27/55 9.52/19.05
Conneting No.*(mm2)*Max L.(m) Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Service Valve Indoor Outdoor Indoor/Outdoor Without S/Parts Liquid/Gas mm mm Kg 20/40ft (mm)
Conneting No.*(mm2)*Max L.(m) Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Service Valve Indoor Outdoor Indoor/Outdoor Without S/Parts Liquid/Gas mm mm Kg 20/40ft (mm)
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
12
13
Ceiling Concealed Duct Type
Ceiling Concealed Duct Type
LB-C488RSS1 LB-C608RSS1
TB-H488RSS0 TB-H608RSS0
LB-C186HSA4
LB-C246HSA4
Features Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)
Features Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)
SpecificationModelCapacity Cooling Heating Electrical Data Power Supply Power Input Running Current Performance EER COP Air Circulation Moisture Removal Noise Level Indoor(H/M/L) Outdoor Max External Static Pressure Cable Main Cooling Heating Indoor(H/M/L) Btu/hr.W W/W CMM l /hr dB(A)3 dB(A)3 mmAq No.*(mm2)*Max L.(m) Cooling / Heating Cooling / Heating ,V,Hz W A Btu/hr Btu/hr
SpecificationLB-C488RSS148,000 3, 380~415, 50 5,750 / 9/8.35 40/35/30 5 46/44/42 59 10 5*3.5 4*1.25*220 1,230x380x590 900x1,165x370 52/95 24/48 9.52/19.05
TB-H488RSS048,000 48,000 3, 380~415, 50 5,600 / 5,000 8.7 / 7.7 8.57 2.81 40/35/30 5 46/44/42 59 10 5*3.5 5*1.25*220 1,230x380x590 900x1,165x370 52/95 24/48 9.52/19.05
LB-C608RSS156,000 3, 380~415, 50 6,800 / 10.5 / 8.24 50/45/40 5.5 49/47/45 60 10 5*3.5 4*1.25*220 1,230x380x590 900x1,165x370 52/105 24/48 12.7/19.05
TB-H608RSS056,000 58,000 3, 380~415, 50 6,800 / 6,250 10.5 / 9.8 8.24 2.72 50/45/40 5.5 49/47/45 60 10 5*3.5 5*1.25*220 1,230x380x590 900x1,165x370 52/105 24/48 12.7/19.05
ModelCapacity Cooling Heating Electrical Data Power Supply Power Input Running Current Performance EER COP Air Circulation Moisture Removal Noise Level Indoor(H/M/L) Outdoor Max External Static Pressure Cable Main Cooling Heating Indoor(H/M/L) Btu/hr.W W/W CMM l /hr dB(A)3 dB(A)3 mmAq No.*(mm2)*Max L.(m) Cooling / Heating Cooling / Heating ,V,Hz W A Btu/hr Btu/hr
LB-C186HSA418,000 1, 220~240, 50 2,000 / 9.2 / 9.0 16/14.5/13 2.0 36/34/32 55 6 3*3.5 4*0.75 880x260x450 801x555x262 35/50 63/134 6.35/15.88
LB-C246HSA424,000 1, 220~240, 50 2,880 / 13 / 8.6 18/16.5/14 2.50 37/35/33 57 6 3*3.5 4*0.75 880x260x450 870x655x320 35/55 52/106 6.35/15.88
Conneting No.*(mm2)*Max L.(m) Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Service Valve Indoor Outdoor Indoor/Outdoor Without S/Parts Liquid/Gas mm mm Kg 20/40ft (mm)
Conneting No.*(mm2)*Max L.(m) Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Service Valve Indoor Outdoor Indoor/Outdoor Without S/Parts Liquid/Gas mm mm Kg 20/40ft (mm)
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
14
15
Ceiling Concealed Duct Type
Ceiling Concealed Duct Type
LB-C306GSA0 LB-C428GSA0
LB-C366GSA0
LB-C488RSA0
LB-C608RSA0
Features Long Distance, High Elevation Weekly Program Standby Power Zero Two Thermistor Control Group Control Child Lock Function Auto Restart EZ Tuning Zone Control(Accessory) High Head Drain Pump(Accessory) Wireless Remote Controller(Accessory) Gold Fin Anti Corrosion(Optional) PLASMA Air Purifying system(Accessory) Central ControllerI(Accessory)
Features Gold Fin Anti Corrosion et CoolTM Auto Cleaning Auto Restart Natural Wind By CHAOS Swing Wireless Remote Controller Quiet Operation Sleep Mode Auto Operation One-Touch Air Filter(Anti-Bacteria) Healthy Dehumidification 24-Hour ON/OFF Setting Timer
SpecificationModelCapacity Cooling Heating Electrical Data Power Supply Power Input Running Current Performance EER COP Air Circulation Moisture Removal Noise Level Indoor(H/M/L) Outdoor Max External Static Pressure Cable Main Cooling Heating Indoor(H/M/L) Btu/hr.W W/W CMM l /hr dB(A)3 dB(A)3 mmAq No.*(mm2)*Max L.(m) Cooling / Heating Cooling / Heating ,V,Hz W A Btu/hr Btu/hr
SpecificationLB-C306GSA030,000 1, 220~240, 50 3,500 / 16.0 / 8.6 28/26/24 3.00 42/40/38 60 8 3*3.5 4*0.75 1,180x298x450 870x800x320 38/60 34/73 6.35/15.88
LB-C366GSA036,000 1, 220~240, 50 4,500 / 20.0 / 8 32/29/26 3.50 42/40//38 59 8 3*5.5 4*0.75 1,180x298x450 870x800x320 38/70 34/73 9.52/15.88
LB-C428GSA042,000 3, 380~415, 50 5,000 / 7.8 / 8.4 32/29/26 4.5 42/40/38 60 8 4*2.5 4*0.25 1,180x298x450 870x1,038x320 38/78 34/73 9.52/15.88
ModelCapacity Cooling Heating Electrical Data Power Supply Power Input Running Current Performance EER COP Air Circulation Moisture Removal Noise Level Indoor(H/M/L) Outdoor Max External Static Pressure Cable Main Cooling Heating Indoor(H/M/L) Btu/hr.W W/W CMM l /hr dB(A)3 dB(A)3 mmAq No.*(mm2)*Max L.(m) Cooling / Heating Cooling / Heating ,V,Hz W A Btu/hr Btu/hr
LB-C488RSA048,000 3, 380~415, 50 5,100 / 8.0 / 9.4 40/35/30 5.00 44/42/40 62 10 4*3.5 4*1.25 1,230x380x590 900x1,165x370 52/95 24/49 9.52/15.88
LB-C608RSA060,000 3, 380~415, 50 6,500 / 10.2 / 9.2 50/45/40 5.50 46/44/42 61 10 4*3.5 4*1.25 1,230x380x590 900x1,165x370 52/105 24/49 12.7/19.05
Conneting No.*(mm2)*Max L.(m) Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Service Valve Indoor Outdoor Indoor/Outdoor Without S/Parts Liquid/Gas mm mm Kg 20/40ft (mm)
Conneting No.*(mm2)*Max L.(m) Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Service Valve Indoor Outdoor Indoor/Outdoor Without S/Parts Liquid/Gas mm mm Kg 20/40ft (mm)
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
16
17
LG AIR CONDITIONERS 2009
Single Packaged Type
Easy InstallationThe unit can be installed outdoors to save valuable indoor space, or in locations where no ceiling space is available. Ground or roof installation options provide total flexibility according to your requirements.
LGs Cooling Load Calculation ProgramSelecting an air conditioner with the right capacity is very important. A unit that is too small or too big will not only affect your comfort, but may also unnecessarily increase your initial purchasing cost and operational expenses. The LG cooling load calculation program helps you choose the right system for your specific needs.
Single Packaged TypeEconomical and user-friendly model, designed for medium-sized houses and shops. Features include a number of operation modes, auto restart and a washable anti-bacterial filter.
Easy Maintenance & ServiceThe all-in-one design, with all access panels located on one side of the unit and color-coded wiring, greatly facilitates maintenance and service.
Single Packaged Type
Typical Installation Roof Jack Installation Roof Curb Installation Slab-on-Ground Installation
Additional functions available with duct systemAll units are designed for reverse-cycle operation, which means electric heating functions can be added by specialized dealers. This model also allows complete control over fresh air intake, ratio of air purification, as well as monitoring and automatic zone control (additional features available from specialized dealers), through the powerful LG control system.
18
Free & Easy Air-CirculationA duct system allows you to freely control air-circulation.
19
Single Packaged Type
Single Packaged Type
TK-C0368HA0 TK-C0608HA0
TK-C0488HA0
TK-C0728H00
TK-C0908H00
* The exact appearance of products may vary from the images shown here.
* The exact appearance of products may vary from the images shown here.
Features Compact & Lightweight Design U-shape Air Flow Safety Condenser Fin Guard Forklift Base rail Easy access Panel Time Delay Relay is Standard Component Low Pressure Switch is Standard Component Durable Painted Steel Cabinet Scroll Compressor with internal high-pressure & Over-current Protector Factory Charged Refrigerant Direct-drive multi-speed PSC Blower Motor Direct-drive PSC Condenser Fan Motor Phase reversal Protection
Features Wired LCD Remote Controller Easy Installation Auto Restart Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System
SpecificationModelCapacity Cooling Heating Electrical Data Power Supply M.C.A(with standard motor) Cooling / Heating Power Input Performance Air Circulation Sound Rating Installation & Stuffing Net Dimensions Net Weight Stuffing Quantity (WxHxD) Indoor/Outdoor mm Kg Indoor CMM bell Cooling / Heating ,V,Hz Amps W Btu/hr Btu/hr
SpecificationTK-C0368HA035,700 3, 380~415,50 13.2 4,000 34 7.7 1,111x824x734 110 30/64/96
TK-C0488HA048,400 3, 380~415,50 17 4,900 45.3 7.9 1,111x824x734 120 30/64/96
TK-C0608HA059,900 3, 380~415,50 21.6 6,400 56.7 8.0 1,111x824x734 140 30/64/96
ModelCapacity Cooling Heating Electrical Data Power Supply M.C.A(with standard motor) Cooling / Heating Power Input Performance Air Circulation Sound Rating Installation & Stuffing Net Dimensions Net Weight Stuffing Quantity (WxHxD) Indoor/Outdoor mm Kg Indoor CMM bell Cooling / Heating ,V,Hz Amps W Btu/hr Btu/hr
TK-C0728H0072,000 3, 380~415,50 22.8 8,600 73.1 7.6 1,784x1,147x1,202 260 8/18/18
TK-C0908H0096,000 3, 380~415,50 24.7 9,500 81.3 8.5 1,784x1,147x1,202 310 8/18/18
Without S/Parts 20/40/40ft Hi
Without S/Parts 20/40/40ft Hi
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
20
21
Single Packaged Type
Single Packaged Type
TK-C1208H00
TK-C1508H00
GK-C1808C00 GK-C2408C00 GK-C3608H00
GK-C2108C00 GK-C3008C00
* The exact appearance of products may vary from the images shown here.
* The exact appearance of products may vary from the images shown here.
Features Washable Anti-bacteria Filter Wired LCD Remote Controller Easy Installation Oversized moter (Accessory) Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Auto Restart
Features Washable Anti-bacteria Filter Wired LCD Remote Controller Easy Installation Oversized moter (Accessory) Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Auto Restart
SpecificationModelCapacity Cooling (Gross) Heating Electrical Data Power Supply M.C.A(with standard motor) Cooling / Heating Power Input Performance Air Circulation Sound Rating Installation & Stuffing Net Dimensions Net Weight Stuffing Quantity (WxHxD) Indoor/Outdoor mm Kg Indoor CMM bell Cooling / Heating ,V,Hz Amps W Btu/hr Btu/hr
SpecificationTK-C1208H00112,600 3, 380~415,50 24.9 13,500 104 8.5 2,110x1,250x1,280 400 4/9/18
TK-C1508H00129,600 3, 380~415,50 33 15,600 155 8.6 2,110x1,250x1,280 400 4/9/18
ModelCapacity Cooling (Gross) Heating Electrical Data Power Supply M.C.A(with standard motor) Cooling / Heating Power Input Performance Air Circulation Sound Rating Installation & Stuffing Net Dimensions Net Weight Stuffing Quantity (WxHxD) Indoor/Outdoor mm Kg Indoor CMM bell Cooling / Heating ,V,Hz Amps W Btu/hr Btu/hr
GK-C1808C00175,000 3, 380~415,50 52.7 18,000 165 9.2 2,230x1,244x1,540 550 3/7/14
GK-C2108C00197,000 3, 380~415,50 57 20,500 198 9.2 2,230x1,244x1,540 600 3/7/14
GK-C2408C00238,900 3, 380~415,50 68.4 25,000 226 9.2 2,893x1,250x2,200 870 1/4/8
GK-C3008C00280,400 3, 380~415,50 80.1 28,500 280.0283 9.2 2,893x1,250x2,200 870 1/4/8
GK-C3608H00360,000 3, 380~415,50 86.4 33,000 311 10 2,688x1,720x2,220 1,070 2/4/4
Without S/Parts 20/40/40ft Hi
Without S/Parts 20/40/40ft Hi
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
22
23
Ducted Split Type
TN-C0368SA0 TN-C0608SA0
TN-C0488SA0
Ducted Split TypeEconomical and user-friendly model, designed for medium-sized houses and shops. Features include a number of operation modes, auto restart and a washable anti-bacterial filter. LED Wired Remote Controller
Features 4way Convertibility-horizontal(Left & right), up-flow, down-flow Plastic drain Pan High efficient Evaporator Coil Galvanized Steel with painting Washable and Anti-fungus Filter Multi-speed blower Time delay PCB 220V primary & 24V secondary transformer Defrost sensor Hi-Reliability Compressor Factory supplied charge of R-22 Compressor internal overload protection Internal pressure relief valve provides high pressure protection for compressor Outside pressure taps for refrigerant system check.
SpecificationModelCapacity Cooling (Gross) Heating Electrical Data Power Supply M.C.A(with standard motor) Cooling / Heating Power Input Performance Air Circulation Sound Rating Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Indoor Outdoor Indoor/Outdoor mm mm Kg Indoor CMM bell Cooling / Heating ,V,Hz Amps W Btu/hr Btu/hr
TN-C0368SA037,000 3, 380~415,50 9.7 4,100 21.6 6 470x1,014x480 870x800x320 59/65 32/66/66
TN-C0488SA049,500 3, 380~415,50 13.9 5,000 50.9 6.2 600x1,135x500 900x1,135x370 63/100 12/26/26
TN-C0608SA060,000 3, 380~415,50 16.5 5,800 53.8 6.2 600x1,135x500 900x1,135x370 65/115 12/26/26
Without S/Parts 20/40/40ft Hi
Note :Due to our policy of innovation some specifications may be changed without notification.
Air Filter Guide
Blower Housing Assembly
A Type Indoor Coil
Plastic Drain Pan
25
Ducted Split Type
Ducted Split Type
TN-C0908T00
TN-C1208T00
TN-C1508T00 TN-C2408T00
TN-C1808T00
Features Compact Size Quick and Easy Service Panels Anti-fungus, Hygienic and Easy-to-Clean filter Convertible lnstallation Safety Condenser Fin Guard High/Low Static Driver Kit, Over Sized Motor(Accessory) LCD Wired Remote Control
Features Compact Size Quick and Easy Service Panels Anti-fungus, Hygienic and Easy-to-Clean filter Convertible lnstallation Safety Condenser Fin Guard High/Low Static Driver Kit, Over Sized Motor(Accessory) LCD Wired Remote Control
SpecificationModelCapacity Cooling (Gross) Heating Electrical Data Power Supply M.C.A(with standard motor) Cooling / Heating Power Input Performance Air Circulation Sound Rating Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Indoor Outdoor Indoor/Outdoor mm mm Kg Indoor CMM bell Cooling / Heating ,V,Hz Amps W Btu/hr Btu/hr
SpecificationTN-C0908T0080,900 3, 380~415,50 20 8,100 76.4 6.0 1,760x890x840 855x1,570x740 190/175 6/15/22
TN-C1208T00111,200 3, 380~415,50 30 11,800 102 6.3 1,760x890x840 1,330x1,570x740 190/300 6/15/19
ModelCapacity Cooling (Gross) Heating Electrical Data Power Supply M.C.A(with standard motor) Cooling / Heating Power Input Performance Air Circulation Sound Rating Installation & Stuffing Net Dimensions (WxHxD) Net Weight Stuffing Quantity Indoor Outdoor Indoor/Outdoor mm mm Kg Indoor CMM bell Cooling / Heating ,V,Hz Amps W Btu/hr Btu/hr
TN-C1508T00135,200 3, 380~415,50 35 13,200 125 8.0 1,760x890x840 1,130x1,180x1,100 190/250 7/14/19
TN-C1808T00179,700 3, 380~415,50 57.2 20,400 150 8.0 2,065x680x1,160 1,640x1,130x880 200/280 7/14/19
TN-C2408T00240,000 3, 380~415,50 76.2 27,200 200 8.0 1,870x980x1,230 1,840x1,130x970 230/340 7/14/19
Without S/Parts 20/40/40ft Hi
Without S/Parts 20/40/40ft Hi
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
26
27
LG AIR CONDITIONERS 2009
Fan Coil Unit
Slim & Compact SizeThe structures using CAD & CAE technology helps users reduce installation spaces. Slim and compact design based on CAD/CAE systems enables user to reduce installation space.
Durable & Energy Saving PCM FinPCM Fin coated with anti corrosive & hydrophilic layers prevents corrosion and make itself remains as like initial condition, therefore it saves power & maintenance cost. Heat Exchanger fins are coated with anticorrosive & hydrophilic layers. It prevents the corrosion of heat exchanger. Fins remain as new even after long time of operation and maintains efficiency of heat exchanger constant.
Fan Coil UnitThe FCU (Fan Coil Unit) is supplied with cold or hot water by the control center and circulates indoor air through the cooling and heating coils.
230
260
LG (WxHxD): 1,090x230x524
The other companies (WxHxD): 1,020x260x515
Fan Coil Unit
LG PCM FIN
The other companies UNCOATED AL
Easy MaintenanceEasily removable motor & blower and removable panels help users maintain units more conveniently. Each unit is designed to occupy a minimum space. This feature, along with convenient wiring and piping connections, means reduces costs on renovations or new construction sites. 260 230
28 29
Fan Coil Unit
Fan Coil Unit
YBNC036ACA0 YBNC046BCA0 YBNC066CCA0 YBNC086DCA0 YBNC106ECA0 YBNC126FCA0 YBNC146GCA0
YBNC126HDA0 YBNC146JDA0 YBNC166KDA0 YBNC186KDA0 YBNC206DLA0
Features Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System District Cooling / Low Static
Features Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System District Cooling / HighStatic
SpecificationModelPerformance Nominial Air Flow H/M/L CFM Btu/h GPM(US) kPa / ft.wg.
4 Rows CoilYBNC036ACA0416/354/283 1,320 3,740 / 1,227 32 / 35 / 40 3 / 8 (9.52) 4R 8C 11FPIsq.m m/s
SpecificationModelPerformance Nominial Air Flow H/M/L CFM Btu/h GPM(US) kPa / ft.wg.
4 Rows CoilYBNC126HDA01,348 / 1,115 / 1,051 37,028 / 31,455 / 28,123 3,800 7,200 / 2,361 50 / 53 / 59 3 / 8 (9.52) 4R 12C 13FPIsq.m m/s
YBNC046BCA0508/424/341 1,850 7,590 / 2,490 28 / 34 / 40 3 / 8 (9.52) 4R 8C 11FPI 0.142 1.69
YBNC066CCA0640/512/430 2,270 11,540 / 3,785 35 / 40 / 43 3 / 8 (9.52) 4R 8C 11FPI 0.189 1.60
YBNC086DCA0869/736/577 3,190 12,050 / 3,952 35 / 40 / 44 3 / 8 (9.52) 4R 8C 11FPI 0.244 1.68
YBNC106ECA01,100/924/742 3,650 13,920 / 4,566 35 / 40 / 44 3 / 8 (9.52) 4R 8C 11FPI 0.284 1.83
YBNC126FCA01,242/1,048/848 4,460 17,550 / 5,756 37 / 41 / 45 3 / 8 (9.52) 4R 8C 11FPI 0.325 1.80
YBNC146GCA01,422/1,195/948 4,840 30,330 / 9,948 38 / 43 / 48 3 / 8 (9.52) 4R 8C 11FPI 0.345 1.95
YBNC146JDA01,513 / 1,338 / 1,196 43,099 / 36,650 / 32,745 4,520 9,400 / 3,082 51 / 55 / 60 3 / 8 (9.52) 4R 12C 13FPI 0.274 2.41
YBNC166KDA01,702 / 1,562 / 1,296 47,219 / 41,558 / 37,474 5,120 11,000 / 3,607 49 / 55 / 59 3 / 8 (9.52) 4R 12C 13FPI 0.329 2.293 - Speed Permanent Split Capacitor Motor
YBNC186KDA01,901 / 1,674 / 1,428 51,088 / 45,105 / 39,659 5,560 12,900 / 4,230 51 / 57 / 59 3 / 8 (9.52) 4R 12C 13FPI 0.329 2.59
YBNC206DLA02,089 / 1,928 / 1,638 55,530 / 47,889 / 41,737 5,900 14,400 / 4,623 53 / 58 / 62 3 / 8 (9.52) 4R 12C 13FPI 0.411 2.30
Nominial Total Capacity H / M / L Water Flow Rate Water Pressure Drop Indoor Noise Level Noise Level Coil Tube Size No. of Rows, Columns & FPI Face Area Face Velocity Motor Type No. of motor Class Power Supply Total Rating Input Fan Material Type No. of Fans Water Content 3 Rows Drain Pan Drain Pan (Material / Thickness) Insulator (Meterial / Thickness) Filter Material No. of Filter L / M /H
10,130/9,144/6,960 14,252/11,874/9,519 17,783/15,968/12,590 24,921/22,656/17,640 28,893/25,999/21,530 35,089/31,970/25,624 38,150/35,280/28,217
Nominial Total Capacity H / M / L Water Flow Rate (Middle) Water Pressure Drop (Middle) Indoor Noise Level
dB(A)
Noise Level Coil
L / M /H
dB(A)
inch(mm)
Tube Size No. of Rows, Columns & FPI Face Area Face Velocity Motor
inch(mm)
0.122 1.61
0.237 2.39
3 - Speed Permanent Split Capacitor Motor #
Type
1 B 1 / 50 / 220~240 67
1 B 1 / 50 / 220~240 75
1 B 1 / 50 / 220~240 102
2 B 1 / 50 / 220~240 152Galvanized Steel Centrifugal Fan (Forward Curve)
2 B 1 / 50 / 220~240 188
2 B 1 / 50 / 220~240 198
3 B 1 / 50 / 220~240 280
No. of motor Class Power Supply Total Rating Input (Middle) Fan Material Type
#
2 B 1 / 50 / 220~240 330
2 B 1 / 50 / 220~240 440
2 B 1 / 50 / 220~240 480Galvanized Steel Centrifugal Fan (Forward Curve)
2 B 1 / 50 / 220~240 550
2 B 1 / 50 / 220~240 650
Ph/Hz/V watt
Ph/Hz/V watt
#
2 1.183
2 1.381
2 1.834
3 2.366Galvanized Steel / T0.8 PE / T5.0
4 2.761
4 3.155
5 3.352
No. of Fans Water Content
#
2 2.66
2 3.01
2 3.07Galvanized Steel / T0.8 PE / T5.0
2 3.07
2 3.80
Liter
3 Rows Drain Pan Drain Pan (Material / Thickness) Insulator (Meterial / Thickness) Filter
Liter
Synthetic Nylon (optional Aluminum)
Material
Synthetic Nylon (optional Aluminum)
1
1
1
1
1
1
1
No. of Filter
1
1
1
1
1
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
30
31
Fan Coil Unit
Fan Coil Unit
YBNB036AAA0 YBNB046BAA0 YBNB066CAA0 YBNB086DAA0 YBNB106EAA0 YBNB126FAA0 YBNB146GAA0
YBNB126HBA0 YBNB146JBA0 YBNB166KBA0 YBNB186KBA0 YBNB206LBA0
Features Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / Low Static
Features Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / High Static
SpecificationModelPerformance Nominial Air Flow H/M/L CFM Btu/h GPM(US) kPa / ft.wg.
3 Rows CoilYBNB036AAA0306/253/200 2,780 4,950 / 1,624 32 / 35 / 40 3 / 8 (9.52) 3R 8C 11FPIsq.m m/s
SpecificationModelPerformance Nominial Air Flow H/M/L CFM Btu/h GPM(US) kPa / ft.wg.
4 Rows CoilYBNB126HBA01,238 / 1,052 / 941 38,385 / 33,642 / 29,173 8,640 21,920 / 7,190 44 / 48 / 52 3 / 8 (9.52) 3R 12C 13FPIsq.m m/s
YBNB046BAA0432/379/329 3,400 6,070 / 1,991 28 / 33 / 40 3 / 8 (9.52) 3R 8C 11FPI 0.142 1.47
YBNB066CAA0686/570/484 5,000 16,300 / 5,346 35 / 39 / 42 3 / 8 (9.52) 3R 8C 11FPI 0.189 1.70
YBNB086DAA0859/765/647 6,210 20,510 / 6,727 35 / 39 / 42 3 / 8 (9.52) 3R 8C 11FPI 0.244 1.69
YBNB106EAA01,059/946/812 7,040 26,630 / 8,735 35 / 40 / 44 3 / 8 (9.52) 3R 8C 11FPI 0.284 1.69
YBNB126FAA01,182/1,053/929 8,510 28,840 / 9,460 37 / 41 / 45 3 / 8 (9.52) 3R 8C 11FPI 0.325 1.80
YBNB146GAA01,728/1,270/1,082 10,990 31,070 / 10,191 37 / 43 / 48 3 / 8 (9.52) 3R 8C 11FPI 0.345 1.97
YBNB146JBA01,441 / 1,225 / 1,095 43,844 / 37,123 / 33,608 9,890 24,810 / 8,138 46 / 49 / 54 3 / 8 (9.52) 3R 12C 13FPI 0.274 2.48
YBNB166KBA01,594 / 1,403 / 1,265 47,086 / 41,285 / 37,941 10,700 28,040 / 9,197 47 / 52 / 56 3 / 8 (9.52) 3R 12C 13FPI 0.329 2.293 - Speed Permanent Split Capacitor Motor
YBNB186KBA01,803 /1,591/ 1,400 49,815 / 43,674 / 38,556 11,400 34,040 / 11,165 49 / 54 / 57 3 / 8 (9.52) 3R 12C 13FPI 0.329 2.59
YBNB206LBA02,006 / 1,759 / 1,548 56,639 / 49,815 / 42,991 12,990 38,300 / 12,562 51 / 55 / 59 3 / 8 (9.52) 3R 12C 13FPI 0.411 2.30
Nominial Total Capacity H / M / L Water Flow Rate Water Pressure Drop Indoor Noise Level Noise Level Coil Tube Size No. of Rows, Columns & FPI Face Area Face Velocity Motor Type No. of motor Class Power Supply Total Rating Input Fan Material Type No. of Fans Water Content 3 Rows Drain Pan Drain Pan (Material / Thickness) Insulator (Meterial / Thickness) Filter Material No. of Filter L / M /H
12,249/11,294/8,803 14,876/13,898/10,884 21,905/19,790/15,968 27,637/24,839/21,018 31,049/28,490/24,566 37,805/34,188/28,081 48,621/43,947/37,020
Nominial Total Capacity H / M / L Water Flow Rate Water Pressure Drop Indoor Noise Level
dB(A)
Noise Level Coil
L / M /H
dB(A)
inch(mm)
Tube Size No. of Rows, Columns & FPI Face Area Face Velocity Motor
inch(mm)
0.122 1.18
0.237 2.47
3 - Speed Permanent Split Capacitor Motor #
Type
1 B 1 / 50 / 220~240 60
1 B 1 / 50 / 220~240 70
1 B 1 / 50 / 220~240 97
2 B 1 / 50 / 220~240 148Galvanized Steel Centrifugal Fan (Forward Curve)
2 B 1 / 50 / 220~240 178
2 B 1 / 50 / 220~240 182
3 B 1 / 50 / 220~240 250
No. of motor Class Power Supply Total Rating Input Fan Material Type
#
2 B 1 / 50 / 220~240 334
2 B 1 / 50 / 220~240 396
2 B 1 / 50 / 220~240 428Galvanized Steel Centrifugal Fan (Forward Curve)
2 B 1 / 50 / 220~240 517
2 B 1 / 50 / 220~240 710
Ph/Hz/V watt
Ph/Hz/V watt
#
2 0.887
2 1.036
2 1.376
3 1.775Galvanized Steel / T0.8 PE / T5.0
4 2.071
4 2.366
5 2.514
No. of Fans Water Content
#
2 1.99
2 2.18
2 2.30Galvanized Steel / T0.8 PE / T5.0
2 2.30
2 2.85
Liter
3 Rows Drain Pan Drain Pan (Material / Thickness) Insulator (Meterial / Thickness) Filter
Liter
Synthetic Nylon (optional Aluminum)
Material
Synthetic Nylon (optional Aluminum)
1
1
1
1
1
1
1
No. of Filter
1
1
1
1
1
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
32
33
Fan Coil Unit
Fan Coil Unit
YBNC126HBA0 YBNC146JBA0 YBNC166KBA0
YBNC186KBA0 YBNC206LBA0
Features Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / High Static
Features Washable Anti-bacteria Filter Easy Installation Free Easy Air-Circulation Low Noise Level Easy Maintenance & Service Additional Functions Available with Duct System Standard / High Static
SpecificationModelPerformance Nominial Air Flow H/M/L CFM Btu/h GPM(US) kPa / ft.wg.
4 Rows CoilYBNC126HBA01,348 / 1,115 / 1,051 44,066 / 38,764 / 33,927 8,600 28,300 / 9,279 50 / 53 / 59 3/8 (9.52) 4R 12C 13FPIsq.m m/s
SpecificationModelPerformance Nominial Air Flow H/M/L CFM Btu/h GPM(US) kPa / ft.wg.
4 Rows CoilYBNC186KBA01,901 / 1,674 / 1,428 63,412 / 54,814 / 47,326 12,160 36,500 / 11,967 51 / 57 / 59 3/8 (9.52) 4R 12C 13FPIsq.m m/s
YBNC146JBA01,513 / 1,338 / 1,196 53,022 / 46,645 / 40,842 10,340 30,000 / 9,836 51 / 55 / 60 3/8 (9.52) 4R 12C 13FPI 0.274 2.413 - Speed Permanent Split Capacitor Motor
YBNC166KBA01,702 / 1,562 / 1,296 56,713 / 50,873 / 46,072 11,280 31,800 / 10,426 49 / 55 / 59 3/8 (9.52) 4R 12C 13FPI 0.274 2.41
YBNC206LBA02,089 / 1,928 / 1,638 73,802 / 64,129 / 54,814 14,220 54,100 / 17,738 53 / 58 / 62 3/8 (9.52) 4R 12C 13FPI 0.411 2.303 - Speed Permanent Split Capacitor Motor
Nominial Total Capacity H / M / L Water Flow Rate (Middle) Water Pressure Drop (Middle) Indoor Noise Level Noise Level Coil Tube Size No. of Rows, Columns & FPI Face Area Face Velocity Motor Type No. of motor Class Power Supply Total Rating Input (Middle) Fan Material Type No. of Fans Water Content 3 Rows Drain Pan Drain Pan (Material / Thickness) Insulator (Meterial / Thickness) Filter Material No. of Filter L / M /H
Nominial Total Capacity H / M / L Water Flow Rate (Middle) Water Pressure Drop (Middle) Indoor Noise Level
dB(A)
Noise Level Coil
L / M /H
dB(A)
inch(mm)
Tube Size No. of Rows, Columns & FPI Face Area Face Velocity Motor Type
inch(mm)
0.237 2.39
0.329 2.59
#
2 B 1/50/220~240 330
2 B 1/50/220~240 440Galvanized Steel Centrifugal Fan (Forward Curve)
2 B 1/50/220~240 480
No. of motor Class Power Supply Total Rating Input (Middle) Fan Material Type
#
2 B 1/50/220~240 550Galvanized Steel Centrifugal Fan (Forward Curve)
2 B 1/50/220~240 650
Ph/Hz/V watt
Ph/Hz/V watt
#
2 2.66
2 3.01Galvanized Steel / T0.8 PE / T5.0
2 3.01
No. of Fans Water Content
#
2 3.07Galvanized Steel / T0.8 PE / T5.0
2 3.80
Liter
3 Rows Drain Pan Drain Pan (Material / Thickness) Insulator (Meterial / Thickness) Filter
Liter
Synthetic Nylon (optional Aluminum)
Material
Synthetic Nylon (optional Aluminum)
1
1
1
No. of Filter
1
1
Note :Due to our policy of innovation some specifications may be changed without notification.
Note :Due to our policy of innovation some specifications may be changed without notification.
34
35
LG AIR CONDITIONERS 2009
Multi Mdx are freely interchangeable multi systems with MPS-controlled, constant speed compressors. These systems are perfectly suited for tropical conditions.
Multi Mdx are freely interchangeable multi systems with MPS-controlled, constant speed compressors. These systems are perfectly suited for tropical conditions.
MULTI
M DX36 37
LG AIR CONDITIONERS 2009
Tropical MPS Multi System Installation Next Generation LG MPS Tropical Multi System
are freely interchangeable multi systems with MPS-controlled, constant speed compressors. These systems are perfectly suited for tropical conditions.
Outdoor Unit Line-upMPS Variable System - High efficiency - High reliability - Long piping & high elevation flexibility - Max.8 indoor units by simple piping - Low noise - Central control
L4UC608FA2
L5UC728FA3 L6UH728FA2
Single Piping Type* Made in Thailand
L8UC1008FA3 L8UC1008FA2 L8UC1508FA1
Indoor Unit Line-upType Btu/h 12K 18K 24K 30K 36K 48KMULTI
M DX
Wall-Mounted*Metal *White Wood
Color variable*Blue *Cherry
ARTCOOL Mirror
High Staic Duct
38 39
MPS Variable Control is LGs unique, energy-saving control technology, which is applied in both the Multi MDX series.
Low Staic Duct
4-Way Cassette
LG AIR CONDITIONERS 2009
Tropical MPS Multi System Installation Next Generation LG MPS Tropical Multi System
Tropical MPS Multi System Solutions
Small Office Building
Residential Building
MULTI
M DX40 41
For Commercial Sites
For Residential Sites
Small Office
Small Shop
Restaurant
Resort
Apartment
Villa
LG AIR CONDITIONERS 2009
Tropical MPS Multi System Installation Next Generation LG MPS Tropical Multi System
Energy Saving with Tropical MPS Variable ControlBasic Principle of Tropical MPS Variable ControlThe Tropical MPS (multi power system) control two or more constant speed compressors, a hot gas bypass circuit and an linear expansion valve (LEV). With multiple compressors operating according to increasing cooling requirements, considerable amounts of energy can be saved. In case of a low cooling load, only one compressor will operate. When the cooling load increases, both compressors will operate and balance the load.
Long Distance & High Elevation PipingThe finely tuned refrigerant return ratio and special accumulator allow piping lengths of up to 110m at a max. elevation of 45m. The runback returns refrigerant to the compressor to maintain a safe level of refrigerant at all times. It allows better flexibility for installation under difficult structural conditions.
Long Distance & High Elevation Piping: Max. Pipe Length: 110m/cycle
100% 50% Conventional system (On/Off Operation) 50% MPS Variable Control
MULTI
Power Consumption ComparisonMPS Variable Multi system opeates in one cycle with two compressors. Only one compressor or two compressors run together, according to the load conditions.With small load. only one compressor completes the cycle. It saves power consumption at low operation. This concept is explained in the picture below.
Simple & Cutting Edge Control System- Please Refer to Page 64
M DX
Tropical Compressor TechnologyThe Tropical compressor is highly reliable, even under extreme conditions (15~60C average), sandstorms and 24 hour operation. At extreme temperatures over 54C only 1 large compressor operates to protect the smaller compressors and to prevent the indoor temperature from rising due to repeated OLP triggering.
42 43
BLDC FanStandard BLDC fan motor offers additional energy saving in operating mode. Compared with AC motors, BLDC fan motor can cut energy by 35%at full velocity. AC motor is operating at full velocity only, but BLDC Motor can change velocity according to load. Energy efficiency levels at low velocities in particular have been improved by 65%. Max Press.(kgf/cm2) Td (C) Under voltage Noise 28 110 10%New Design -muffle -resonator
Tropical 33 115 15%
INCREASED RELIABILITY- Overload Protector - High Torque Motor - Special Anti-Wear Coating - High Rigidity Crank Shaft
LG AIR CONDITIONERS 2009
Tropical MPS Multi System Installation Next Generation LG MPS Tropical Multi System
Flexible Design & Simple PipingThe MPS Variable multi system uses a simple refrigerant pipe to connect one outdoor unit with multiple indoor units. It is easy to install and very economical. Various distributors for flexible design Connecting distributor without brazing
Distributor Type
The Tropical MPS Multi allows simple piping for easy installation by using branch distributors.
A,B : Main piping L1,L2,L3,L4,L5,L6,L7,L8 : Branch piping The specifications above are only for two models, L8UC1008FA3/L8UC1508FA1. Please refer to the Product Data Book for other models.Indoor Unit L1
L1 L2 L3
Outdoor Unit (L8UC1008FA3)
A
L2
Branch DistributorL3
Installation of the outdoor unit in an upper position
Installation of outdoor unit in lower position
B
Branch Distributor
L4 L5 L6
45m
L4B
For 2 Room
For 3 Room
For 4 Room
L5 L6
45mA
L7
Branch Distributor
L8
Branch DistributorL7 L8 Indoor Unit
Outdoor Unit (L8UC1008FA3)
Direct Connection TypePiping length : 50m(A), 50m(B) Total system piping length : 100m(50+50)(Please refer to PDB for detail piping spec.)Total main piping length : 50m(A), 50m(B) With L5UC728FA3, L8UC1008FA3, L8UC150FA1 Total branch piping length : 60m(L1+L2+L3+L4), 60m(L5+L6+L7+L8) Maximum length of single branch piping: 15m(L1, L2, L3,L4, L5, L6, L7, L8) Total system piping length: 220m = 110m(A+L1+L2+L3+L4)+110m(B+L5+L6+L7+L8) Maximum elevation from outdoor unit to indoor unit : 45m with L5UC728FA3, L8UC1008FA3, L8UC150FA1Indoor Unit
MULTI
M DX
Easy installation with various distributorsAIndoor Unit Outdoor Unit (L8UC1008FA3)
BIndoor Unit 45m 45m Indoor Unit
Unit
PMBD5420L
PMBD5430L
PMBD5440L
DistributorForConnectable indoor Unit Power Consumption Running Current Net Dimensions Net Weight Piping Connection (Outdoor Unit) Piping Connection (Indoor Unit) (W) (A) (mm) (kg) (mm) (mm)
B
A
2 indoors1~2 10 0.05 300 x 150 x 250 4.8 9.52 / 19.05 6.35x2 / 12.7x2
3 indoors1~3 10 0.05 300 x 150 x 250 4.9 9.52 / 19.05 6.35x3 / 12.7x3
4 indoors1~4 10 0.05 300 x 150 x 250 5.0 9.52 / 19.05 6.35x4 / 12.7x4
Short Tube Installation of outdoor unit in an elevated position
Outdoor Unit (L8UC1008FA3)
Type (WxHxD) Liquid / Gas Liquid / Gas
Installation of outdoor unit in a lower position
44 45
A variety of distributors makes installation on any site much easier.Notes: 1.BD unit BD unit, Indoor Unit Indoor Unit : Max. Height - 10m Set up the BD unit and Indoor Unit in 15m. 2. Piping connectors must fit the piping sizes of the indoor unit to be connected.(If required, use the connector which is included with the indoor unit.) 3. The BD unit should be installed inside the building.
Various Combination4 Room Type 5~6 Room Type 8 Room Type
Short Tube
Y Branch
Use short tube in case of connecting 48K indoor unit to outdoor unit(direct piping) For detailed usage of short tube and Y-branch, please refer to PDB
L4UC608FA2 / L5UC728FA3 / L6UH728FA2
L8UC1008FA3 / L8UH1008FA2 / L8UC1508FA1
SpecificationHP Nomal Capacity (Min~Rating) Cooling Heating Nominal Input (Min~Rating) Running Current Cooling Heating Cooling Heating Cooling/Heating kW Btu/h kW Btu/h kW kW A A A , V, Hz No.*mm2 No.*mm2 No.*mm2 mm(inch) kg(Ibs) L4UC608FA2 5.3~17.6 18,000~60,000 2.9~5.7 5.3~10.2 24 3, 380~415, 50 5 * 50 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 900*1,165*370 (35.4*45.8*14.5) 104 (230) 4 Twin Rotary 2 x QPT525YAB 3 Phase Induction SUNISO NM56 1,200 3,400 (120) R22 MPS cycle EEV In BD unit Single cycle EEV in outdoor unit (2R x 26C x 18) * 2 6/370~400 Direct drive side 80 (2,824) x 1 60 9.52 (3/8) 19.05 (3/4) 60 30 30 30 10 L5UC728FA3 3.5~21.1 12,000~72,000 1.9~6.8 3.8~12.3 24 3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 806*1,607*730(31.7*63.3*28.7) 205 (452) 5 Rotary 2 x QPT425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI 1,130 Rotary 1 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI 1,130Cycle 1: 4600(162.21)/Cycle 2:2300(81.1)
SpecificationL6UH728FA2 3.5~21.1 12,000~72,000 3.5~21.1 12,000~72,000 2.2~7.3 2.8~7.2 4.9~14.7 4.8~14.5 24 3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 806*1,607*730(31.7*63.3*28.7) 190 (419) 6 Twin Rotary 2 x QPT425YAB 3 Phase Induction ATMOS M60/SUNISO 4GSI 1,200 Twin Rotary 1 x QP425YAB 3 Phase Induction ATMOS M60/SUNISO 4GSI 1,200Cycle 1: 4000(141)/Cycle 2:2000(70.5)
HP Nomal Capacity (Min~Rating)
Cooling Heating
Nominal Input (Min~Rating) Running Current
Starting Current Power Supply Power Supply Cable (outdoor) Power and transmission cable(outdoor to BD) Power and transmission cable(BD to indoor) Dimensions W*H*D Net Weight Max. Number of Connectable indoor Units Compressor Type constant speed Qty x Model (A+B) Motor Type (MPS cycle 1) Oil Type Oil Charge Compressor Type constant speed Qty x Model (C or C+D) Motor Type (Single or MPS cycle 2) Oil Type Oil Charge Refrigerant Charge (at 7.5m) Type Control
cc
cc g(oz) EEV
Short tube (Row x Column x FPI)*No. Defrosting Method Fan motor Capacitor F/Vac Drive Discharge direction Side/Top Air Flow Rate x No.of fan CMM(cfm) Noise Level (H/L) Sound Pressure at 1m dB(A)+3 Piping connections Liquid()(Circuit 1) mm(inch) Gas()(Circuit 1) Liquid()(Circuit 2) Gas()(Circuit 2) Max.total Piping m BD Max. OD~BD Piping m MPS Piping Multi Max. total sum of BD~ID Piping m MDx Direct Piping Max. OD~ID Piping m Single Max. OD~ID Piping m Max. Elevation Indoor Unit~Outdoor Unit m Difference Indoor Unit~Indoor Unit m Heat ExchangerNotes:
R22 MPS cycle EEV In BD unit Single cycle EEV in outdoor unit (079 / - / 079) (2Rx17Cx18)*2+(2Rx36Cx18)*2 10/370 Direct drive top 90 (3,179) x 1 60 9.52 (3/8) 19.05 (3/4) 6.35 (1/4) 15.88 (5/8) 110 50 60 50 50 45 10
R22 MPS cycle EEV In BD unit Single cycle EEV in outdoor unit (079 / - / 079), (085 / - / 096) (2Rx17Cx18)*2+(2Rx36Cx18)*2 Reverse cycle 10/450 Direct drive top 90 (3179) x 1 60 9.52 (3/8) 19.05 (3/4) 6.35 (1/4) 15.88 (5/8) Cycle1:60 / Cycle2:45 Cycle1:30 / Cycle2:30 Cycle1:30 / Cycle2:15 Cycle1:50 / Cycle2: 30 10
Starting Current Power Supply Power Supply Cable (outdoor) Power and transmission cable(outdoor to BD) Power and transmission cable(BD to indoor) Dimensions W*H*D Net Weight Max. Number of Connectable indoor Units Compressor Type constant speed Qty x Model (A+B) Motor Type (MPS cycle 1) Oil Type Oil Charge Compressor Type constant speed Qty x Model (C or C+D) Motor Type (Single or MPS cycle 2) Oil Type Oil Charge Refrigerant Charge (at 7.5m) Type Control Heat Exchanger
Cooling Heating Cooling Heating Cooling/Heating
kW Btu/h kW Btu/h kW kW A A A , V, Hz No.*mm2 No.*mm2 No.*mm2 mm(inch) kg(Ibs)
cc
cc g(oz)
EEV Short tube (Row x Column x FPI)*No.
Defrosting Method Capacitor F/Vac Drive Discharge direction Side/Top Air Flow Rate x No.of fan CMM(cfm) Noise Level (H/L) Sound Pressure at 1m dB(A)+3 Piping connections Liquid()(Circuit 1) mm(inch) Gas()(Circuit 1) Liquid()(Circuit 2) Gas()(Circuit 2) Max.total Piping m BD m Piping Max. OD~BD Piping Piping Multi MPS Max. total sum of BD~ID Piping m MDx Direct Piping Max. OD~ID Piping length m spec. Max. total Piping m Multi M Max. OD~ID Piping m Max. Elevation Indoor Unit~Outdoor Unit m Difference Indoor Unit~Indoor Unit m Fan motorNotes:
L8UC1008FA3 3.5~29.3 12,000~100,000 --1.6~9.9 -3.4~21.8 --3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 1,280*1,607*730(50.4*63.3*28.7) 250 (551) 8 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI 1130 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI 1130 4000(141.1) R22 2 MPS cycle EEV In BD unit (079 / - / 079), (085 / - / 096) (2R x 14C x 18)*2 + (1R x 30C x 18)*2 -10/370 Direct drive top 90 (3179) x 2 60 9.52 (3/8) 19.05 (3/4) 9.52 (3/8) 19.05 (3/4) 110 50 60 50 --45 10
L8UH1008FA2 3.5~29.3 12,000~100,000 3.5~29.3 12,000~100,000 1.6~9.9 2.3~9.0 3.4~21.8 4.2~16.0 -3, 380~415, 50 5 * 5.0 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 1,280*1,607*730(50.4*63.3*28.7) 250 (551) 8 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI 700 Rotary 2 x QP425Y 3 Phase Induction ATMOS M60/SUNISO 4GSI 700 4000(141.1) R22 2 MPS cycles EEV in BD unit (079 / - / 079), (085 / - / 096) (2R x 14C x 18)*2 + (1R x 30C x 18)*2 Reverse cycle 10/370 Direct drive top 90 (3179) x 2 60 9.52 (3/8) 19.05 (3/4) 9.52 (3/8) 19.05 (3/4) 60 30 30 50 --30 10
L8UC1508FA1 5.3~44.0 18,000~150,000 --3.5~16.3 -6.39~29.1 --3, 380~415, 50 5 * 8.4 (includes earth) 4 * 0.75 (includes earth) 4 * 0.75 (includes earth) 1,280*1,607*730(50.4*63.3*28.7) 320 (661) 8 Twin Rotary 3 x QPT525Y 3 Phase Induction SUNISO NM56 1200 Twin Rotary 2 x QPT525Y 3 Phase Induction SUNISO NM56 1200 Cycle1:7200(254)/Cycle2:4800(169) R22 2 MPS cycles EEV in BD unit (2Rx14Cx18)*2+(2Rx30C x18)*1 +(3Rx30Cx18)*1 -10/370 Direct drive top 180 (6357) 60 12.7 (1/2) 25.4 (1) 9.52 (3/8) 19.05 (3/4) 110 50 60 ---45 10
1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB Heating: - Indoor Temperature 20C(68F) DB /15C(59F) WB - Outdoor Temperature 7C(44.6F) DB /6C(42.8F) WB Piping Length: - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. At least two indoor units should be connected.
1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB Heating: - Indoor Temperature 20C(68F) DB /15C(59F) WB - Outdoor Temperature 7C(44.6F) DB /6C(42.8F) WB Piping Length: - Interconnecting Piping Length 7.5m - Level Difference of Zero. 2. At least two indoor units should be connected. 3. Wiring cable size must comply with the applicable local and national code. 4. The specification may be subject to change without prior notice for purpose of improvement.
46
47
Combination of Indoor and Outdoor Unit Combination TableL4UC608FA2 L5UC728FA3
L4UC608FA2Cooling Operation Unit Outdoor Units Indoor Units Capacity Model Type Index Wall MountedGeneralL4UC608FA2 L5UC728FA3 L6UH728FA2 L8UC1008FA3 L8UH1008FA2 L8UC1508FA1
Combination of Indoor unit(k Btu/h) Capacity (Btu/h) Input (W) Unit-A Unit-B Unit-C Unit-D18 24 30 36 48 18 18 18 18 18 24 24 24 30 30 18 18 18 18 24 18 18 24 30 36 48 30 36 48 30 36 18 18 18 18 24 18 18 24 30 36 24 18 18
Current (A)5.3 5.3 5.5 9.0 9.2 9.0 9.2 9.6 9.6 9.8 9.6 9.6 10.2 9.6 9.6 10.2 10.2 9.6 9.6 10.2 10.6
Total18 24 30 36 48 36 42 48 54 66 54 60 72 60 66 54 60 66 72 72 72
Unit-A18000 24000 30000 36000 48000 18000 18000 18000 18000 16000 24000 24000 20000 30000 28000 18000 18000 16000 15000 20000 15000
Unit-B18000 24000 30000 36000 44000 30000 36000 40000 30000 34000 18000 18000 16000 15000 20000 15000
Unit-C18000 23000 28000 30000 20000 15000
Unit-D15000
Total18000 24000 30000 36000 48000 36000 42000 48000 54000 60000 54000 60000 60000 60000 62000 54000 59000 60000 60000 60000 60000 2850 2850 3000 5600 6050 5600 5600 6050 5800 6300 6300 6300 6300 6300 6300 5800 5700 6300 6300 5800 5900
1 unit
Number of Connectible Indoor Units kW 3.52 5.28 7.03 3.52 5.42 7.03 3.2 5.28 7.03 8.79 10.55 14.07 5.28 7.03 8.79 10.55 14.07 3.52 5.28 7.03 up to 4 up to 5 up to 6 up to 8 up to 8
Btu/h 12,000 18,000 24,000 12,000 18,500 24,000 12,000 18,000 24,000 30,000 36,000 48,000 18,000 24,000 30,000 36,000 48,000 12,000 18,000 24,000
ARTCOOL
Mirror
Ceiling Cassette
4 Way
Hight Static
Ceiling Concealed DuctLow Static
12 18 24 12 18 24 12 18 24 30 36 48 18 24 30 36 48 12 18 24
-
2 units
3 units
4 units
Notes: 1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB 2. The total capacity of indoor unit of "Circuit 1" is up to 36000 Btu/h (10.6kW). The total capacity of indoor unit of "Circuit 2" is up to 24000 Btu/h (7.1kW). 3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)]
Notes: 1. The total capacity index of indoor units is the of capacity index of eachunits and shoul be within the maximum capacity index of the outdoor unit.
L5UC728FA3Cooling OperationCircuit Unit
Combination of Indoor units (k Btu/h) Capacity (Btu/h) Input (W) Unit-A Unit-B Unit-C Unit-D48 12 18 18 18 18 24 24 12 12 12 12 12 12 18 12 12 24 36 18 24 30 36 30 24 12 12 12 12 18 18 18 12 12 12 18 24 30 18 24 18 12 12 12 18 -
Current (A)8.2 8.0 8.0 8.0 8.2 8.2 8.2 8.2 7.8 7.8 8.0 8.0 8.0 8.0 8.0 8.0 8.0 4.5
Total48 48 36 42 48 54 54 48 36 42 48 54 48 54 54 48 54 24
Unit-A48000 12000 18000 18000 18000 16000 22000 24000 12000 12000 12000 11110 12000 11110 16670 12000 11000 24000
Unit-B36000 18000 24000 30000 34000 28000 24000 12000 12000 12000 11110 18000 16670 16670 12000 11000 -
Unit-C12000 18000 24000 27780 18000 22220 16670 12000 11000 -
Unit-D12000 17000 -
Total48000 48000 36000 42000 48000 50000 50000 48000 36000 42000 48000 50000 48000 50000 50000 48000 50000 24000 4600 4250 4250 4250 4600 4600 4600 4600 4100 4100 4250 4250 4250 4250 4250 4250 4250 2450
1 unit
2 units
1
3 units
4 units 2 1 unit
Notes: 1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB 2. The maximum capacity available for this model is 54k Btu/hr (15.8kW). 3. The capacity is based on standard length of interconnecting refrigerant line. 4. The number of indoor units that can be installed is from 2 to 4. Below 2 indoor units, installation is not possible. 5. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.
48
49
Combination Table
L6UH728FA2
Combination Table
L8UC1008FA3, L8UH1008FA2
L6UH728FA2Cooling / Heating OperationCircuit Unit
L8UC1008FA3, L8UH1008FA2Cooling / Heating Operation Input (W) Current (A)Circuit Unit 4720 / 4330 4730 / 4640 4580 / 4560 4700 / 4560 4720 / 4630 4790 / 4680 4790 / 4680 4720 / 4630 4580 / 4560 4680 / 4560 4720 / 4640 4790 / 4670 4720 / 4640 4790 / 4670 4790 / 4670 4720 / 4640 4790 / 4670 2550 / 2570 2450 / 2570 9.4 / 9.2 9.4 / 9.3 9.2 / 9.0 9.2 / 9.0 9.4 / 9.3 9.6 / 9.5 9.6 / 9.5 9.4 / 9.3 9.2 / 9.0 9.3 / 9.0 9.4 / 9.3 9.6 / 9.4 9.4 / 9.3 9.6 / 9.3 9.6 / 9.4 9.4 / 9.3 9.6 / 9.4 4.9 / 4.9 4.9 / 4.9
Combination of Indoor unit(k Btu/h) Capacity (Btu/h) Unit-A Unit-B Unit-C Unit-D48 12 18 18 18 18 24 24 12 12 12 12 12 12 18 12 12 24 12 36 18 24 30 36 30 24 12 12 12 12 18 18 18 12 12 12 12 18 24 30 18 24 18 12 12 12 18 -
Combination of Indoor units (k Btu/h) Capacity (Btu/h) Input (W) Unit-A Unit-B Unit-C Unit-D48 12 18 18 18 18 24 24 12 12 12 12 12 12 18 12 12 36 18 24 30 36 30 24 12 12 12 12 18 18 18 12 12 12 18 24 30 18 24 18 12 12 12 18
Total48 48 36 42 48 54 54 48 36 42 48 54 48 54 54 48 54 24 24
Unit-A48000 / 48000 12000 / 12000 18000 / 18000 18000 / 18000 18000 / 18000 16000 / 16000 22000 / 22000 24000 / 24000 12000 / 12000 12000 / 12000 12000 / 12000 11110 / 11110 12000 / 12000 11110 / 11110 16670 / 16670 12000 / 12000 11000 / 11000 24000 / 24000 12000 / 12000
Unit-B-/36000 / 36000 18000 / 18000 24000 / 24000 30000 / 30000 34000 / 34000 28000 / 28000 24000 / 24000 12000 / 12000 12000 / 12000 12000 / 12000 11110 / 11110 18000 / 18000 16670 / 16670 16670 / 16670 12000 / 12000 11000 / 11000 -/12000 / 12000
Unit-C
Unit-D
Total48000 / 48000 48000 / 48000 36000 / 36000 42000 / 42000 48000 / 48000 50000 / 50000 50000 / 50000 48000 / 48000 36000 / 36000 42000 / 42000 48000 / 48000 50000 / 50000 48000 / 48000 50000 / 50000 50010 / 50010 48000 / 48000 50000 / 50000 24000 / 24000 24000 / 24000
Current (A)8.5 / 7.3 8.5 / 7.3 6.0 / 4.9 7.2 / 6.0 8.5 / 7.3 8.6 / 7.5 8.6 / 7.5 8.5 / 7.3 6.0 / 4.9 7.2 / 6.0 8.5 / 7.3 8.6 / 7.5 8.5 / 7.3 8.6 / 7.5 8.6 / 7.5 8.5 / 7.3 8.6 / 7.5
Total48 48 36 42 48 54 54 48 36 42 48 54 48 54 54 48 54
Unit-A48000 / 48000 12000 / 12000 18000 / 18000 18000 / 18000 18000 / 18000 16000 / 16000 22000 / 22000 24000 / 24000 12000 / 12000 12000 / 12000 12000 / 12000 11110 / 11110 12000 / 12000 11110 / 11110 16670 / 16670 12000 / 12000 11000 / 11000
Unit-B-/36000 / 36000 18000 / 18000 24000 / 24000 30000 / 30000 34000 / 34000 28000 / 28000 24000 / 24000 12000 / 12000 12000 / 12000 12000 / 12000 11110 / 11110 18000 / 18000 16670 / 16670 16670 / 16670 12000 / 12000 11000 / 11000
Unit-C
Unit-D
Total48000 / 48000 48000 / 48000 36000 / 36000 42000 / 42000 48000 / 48000 50000 / 50000 50000 / 50000 48000 / 48000 36000 / 36000 42000 / 42000 48000 / 48000 50000 / 50000 48000 / 48000 50000 / 50000 50000 / 50000 48000 / 48000 50000 / 50000 5300 / 4600 5300 / 4600 3800 / 3100 4500 / 3800 5300 / 4600 5400 / 4700 5400 / 4700 5300 / 4600 3800 / 3100 4500 / 3800 5300 / 4600 5400 / 4700 5300 / 4600 5400 / 4700 5400 / 4700 5300 / 4600 5400 / 4700
1 unit
2 units
1
3 units
4 units 2 1 unit 2 unit
-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/12000 / 12000 -/18000 / 18000 -/24000 / 24000 -/27780 / 27780 -/18000 / 18000 -/22220 / 22220 -/16670 / 16670 -/12000 / 12000 12000 / 12000 11000 / 11000 17000 / 17000 -/-/-/-/-
1 unit
2 units 1 or 2 3 units
4 units
-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/-/12000 / 12000 -/18000 / 18000 -/24000 / 24000 -/27780 / 27780 -/18000 / 18000 -/22220 / 22220 -/16670 / 16670 -/12000 / 12000 12000 / 12000 11000 / 11000 17000 / 17000
Notes: 1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB 2. The maximum capacity available for Circuit 1 is 54kBtu/h (15.8kW). The total capacity of indoor unit of "Circuit 2" is up to 24 kBtu/h (7.1kW). 3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)] 4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.
Notes: 1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB 2. Heating Capacity is based on : indoor temp.20C(60F) DB; outdoor temp. 7C(44.6F) DB, 6C(42.8F) WB 3. The maximum capacity available is 54kBtu/h (15.8kW) per circuit. 4. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)] 5. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.
50
51
Combination Table
L8UC1508FA1
Combination Table
L8UC1508FA1
Cooling : There are two different cycles.Cycle 1 : 90 kBtu/hCooling OperationCircuit
Cycle 2 : 60 kBtu/h
Cooling Operation Combination of Indoor units (k Btu/h) Capacity (Btu/h) Input (W) Current (A)Circuit 3380 5980 6220 6460 6940 6220 6465 6700 9000 6700 6940 9370 9000 9700 10500 6460 6700 6900 9000 9730 6940 9000 9370 10100 9370 9700 10400 9000 9300 9700 10400 9700 10100 10400 10100 10400 9000 9300 9700 10100 9700 10100 10400 10100 10400 10400 6.0 10.7 11.0 11.4 12.2 11.1 11.4 11.8 16.1 11.8 12.2 16.7 16.1 17.3 18.5 11.4 11.8 12.2 16.1 17.3 12.2 16.1 16.7 17.9 16.7 17.3 18.4 16.1 16.7 17.3 18.5 17.3 17.9 18.5 17.9 18.5 16.1 16.7 17.3 17.9 17.3 17.9 18.5 17.9 18.5 18.5
Combination of Indoor units (k Btu/h) Capacity (Btu/h) Unit-A Unit-B Unit-C Unit-D18 18 18 18 18 24 24 24 24 30 30 30 36 36 48 18 18 18 18 18 18 18 18 18 18 18 18 24 24 24 24 24 24 24 30 30 18 18 18 18 18 18 18 18 18 24 18 24 30 36 48 24 30 36 48 30 36 48 36 48 48 18 18 18 18 18 24 24 24 24 30 30 30 24 24 24 24 30 30 36 30 30 18 18 18 18 18 18 18 24 24 24
Input (W) Unit Unit-A Unit-B Unit-C Unit-D18 18 18 18 18 24 24 24 24 30 30 18 18 18 18 18 18 24 18 18 24 30 36 48 24 30 36 48 30 36 18 18 18 18 24 24 24 18
Current (A)6.0 10.7 11.0 11.3 11.9 11.0 11.3 11.6 12.2 11.6 11.9 11.3 11.6 11.9 12.2 11.9 12.2 12.2 12.2
Unit
Total36 42 48 54 66 48 54 60 72 60 66 78 72 84 96 54 60 66 72 84 66 72 78 90 78 84 96 72 78 84 96 84 90 96 90 96 72 78 84 90 84 90 96 90 96 96
Unit-A19000 19000 19000 19000 15000 25000 25000 24000 25000 30000 27000 32000 38000 36000 45000 18000 18000 16000 19000 18000 16000 19000 19000 18000 19000 18000 16000 25000 25000 24000 22000 24000 24000 22000 30000 28000 19000 19000 18000 18000 18000 18000 16500 18000 16500 22500
Unit-B19000 25000 31000 37000 45000 25000 31000 36000 49000 30000 33000 50000 38000 48000 45000 18000 18000 16000 19000 18000 22000 25000 25000 24000 31000 30000 28000 25000 25000 24000 22000 30000 30000 34000 30000 28000 19000 19000 18000 18000 18000 18000 16500 24000 22500 22500
Unit-C
Unit-D
Total38000 44000 50000 56000 60000 50000 56000 60000 74000 60000 60000 82000 76000 84000 90000 54000 60000 60000 75000 84000 60000 75000 81000 90000 81000 84000 90000 75000 81000 84000 90000 84000 90000 90000 90000 90000 76000 82000 84000 90000 84000 90000 90000 90000 90000 90000
Total36 42 48 54 66 48 54 60 72 60 66 54 60 66 72 66 72 72 72
Unit-A19000 19000 19000 19000 15000 25000 25000 24000 18000 30000 27000 18000 18000 16000 14000 16000 14000 20000 15000
Unit-B19000 25000 31000 37000 45000 25000 31000 36000 42000 30000 33000 18000 18000 16000 14000 22000 20000 20000 15000
Unit-C
Unit-D
Total38000 44000 50000 56000 60000 50000 56000 60000 60000 60000 60000 54000 60000 60000 60000 60000 60000 60000 60000 3500 5980 6150 6350 6750 6150 6350 6560 6900 6600 6750 6350 6600 6750 6940 6750 6940 6940 6940
2 units
2 units
2
3 units
1
3 units
4 units
18 24 30 36 48 24 30 36 48 30 36 48 24 30 36 48 30 36 36 30 36 18 18 18 18 24 24 24 24 24 24
18 24 30 36 24 30 36 24 30 24
18000 24000 28000 37000 48000 22000 31000 37000 48000 31000 36000 46000 25000 31000 36000 46000 30000 36000 34000 30000 34000 19000 19000 18000 18000 24000 24000 22500 24000 22500 22500
4 units
18 24 30 36 24 30 24 18
18
18000 24000 28000 32000 22000 26000 20000 15000
15000
Notes: 1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB 2. The maximum capacity available for Circuit 1 is 96kBtu/h (28.1kW). The maximum capacity available for Circuit 2 is 72kBtu/h (21.1kW). 3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)] 4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.
19000 25000 30000 36000 24000 30000 34500 24000 28500 22500
Notes: 1. Cooling Capacity is based on : indoor temp.27C(80.6F) DB, 19C(66.2F) WB; outdoor temp. 35C(95F) DB 2. The maximum capacity available for Circuit 1 is 96kBtu/h (28.1kW). The maximum capacity available for Circuit 2 is 72kBtu/h (21.1kW). 3. The capacity is based on standard length of interconnecting refrigerant line. [Standard length : Direct Piping - 7.5m (25ft), Distributor Piping - Main 5m(16.4ft), Branch 7.5m (25ft)] 4. In case of the maximum capacity combinations of indoor unit the capacity might seem to be decreased due to the changes in discharge temperature of indoor units, while the total capacity(i.e. the total sum of indoor units capacity) is to be slightly increased with increasing air flow rate of indoor units with respect to the overall system.
52
53
Wall Mounted Split Type
LG AIR CONDITIONERS 2009
Optimized Cooling & Heating Air FlowCooling mode Heating mode
JET CoolWith the Jet Cool function a strong and cool air stream is blown at high speed for 30 minutes, until the room temperature reaches 18 C
The air vanes will be adjusted according to the mode of operation. In heating mode air will be distributed at a lower angle due to hot air rising.
Model Power Supply Cooling Capacity Heating Capacity / V / Hz kW Btu/h kW Btu/h Current Nominal running current Motor Type Fan Type Motor Output x Number of Unit Air Flow Rate (H) Capacitor cmm cfm F/Vac mm mm(inch) kg(lbs) dB(A)3 Liquid Gas Drain(OD/ID) Dehumidification Rate l/h Safety devices Temperature Sensor Referigerant Referigerant Control Connectable outdoor unit Power and transmission interunit cable (including earth) No.* mm2 mm(inch) mm(inch) mm Drive Coil Weight Air Filter Sound Level (H/M/L) Piping Connections Row x column x FPI Body Dimensions (WxHxD) Body A Fan
LMN(C)H126D4*0 1 / 220~240 / 50 3.52 12,000 3.52 12,000 0.22 Induction Cross Flow Fan 40 x 1 10 353 9.0 / 400 Direct Drive 2R x 15C x 20 840 x 270 x 153(33.1 x 10.6 x 6.0) 7 (15.4) Long Life Filter 40 / 35 / 30 6.35 (1/4) 12.7 (1/2) 21.5 / 16.0 1.5
LMN(C)H186D5*0 1 / 220~240 / 50 5.28 18,000 5.28 18,000 0.28 Induction Cross Flow Fan 62 x 1 13 459 1.5 / 370 Direct Drive 2R x 15C x 20 1,090 x 300 x 180(42.9 x 11.8 x 7.1) 13 (28.7) Long Life Filter 40 / 37 / 33 6.35 (1/4) 12.7 (1/2) 21.5 / 16.0 2.0 Fuse, Thermal Protector for Fan Motor Thermistor
LMN(C)H246D5*0 1 / 220~240 / 50 7.03 24,000 7.03 24,000 0.35 Induction Cross Flow Fan 70 x 1 14 494 2.0 / 370 Direct Drive 2R x 15C x 20 1,090 x 300 x 180(42.9 x 11.8 x 7.1) 13 (28.7) Long Life Filter 45 / 42 / 37 6.35 (1/4) 15.88 (5/8) 21.5 / 16.0 3.1
Even & Fast Air flowLG Electronics air conditioner improves the difference between high and low indoor temperatures . It allows you to reach your desired temperatures even faster
Healthy DehumidificationDehumidification mode reduces uncomfortable humidity from the room without over cooling.
Triple Deodorizing Filter- Triple deodorizing filter is for absorbing VOC ingredient, common odor - Deodorizing efficiency :10% up compared to norma deodorizatior filter
Innovative quiet operationTo provide a comfortable, pleasant and well balanced environment, LG air conditioners utilize a streamlined air fan and a unique design which create smooth air flow from the air conditioner so that it operates under the lowest noise level. The cross flow fan, stabilizer, and rear guide which are the causes of noise, have been redesigned by hydraulic engineering. The number of revolutions have been decreased or increased while the amount of friction has been decreased providing the most quiet air conditioners in the world.
R22 EEV Multi M DX 4 x 0.75 (including earth)
R22 EEV Multi M DX 4 x 0.75 (including earth)
R22 EEV Multi M DX 4 x 0.75 (including earth)
Air Purifying SystemThe Nano PLASMA Air Purifying System, developed uniquely by LG, not only removes microscopic contaminants and dust, but also eliminates house mites, pollen and pet fur to prevent allergic diseases like asthma. It also eliminates bad odors by neutralizing odor particles. With a reusable filter that can simply be cleaned with a vacuum cleaner, you can enjoy clean, fresh air without the cost of regular filter changes.
New chaos swingThe most comfortable airflow for the human body can be found in nature. After countless analysis, LG has applied the scientific chaos theory to its air conditioning range, which effectively produces a natural, fresh breeze. The chaso theory is a technology that recreates the flow of natural air by controlling the angle speed of the movement of the air vane. Chaos swing technology also minimizes the temperature difference between high and low places in the room, creating a more comfortable and cooler environment.
Notes:1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB - Interconnecting Piping Length 7.5 m - Level Difference of Zero. 2. Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. *: See the page "Combination Table"
Odor Free! Dust Free! Allergy Free!
54
55
ARTCOOL Mirror
LG AIR CONDITIONERS 2009
ARTCOOL_Mirror TypeA little interior accent for the modern you. The romantic pastel colors, subdued luster,modern texture and the super slim design of LG ARTCOOL Mirror are the answers to your unique mood and personality.
Model Power Supply Cooling Capacity Heating Capacity Current Fan Nominal running current Motor Type Fan Type Motor Output x Number of Unit Air Flow Rate (H) Capacitor Drive Coil Row x column x FPI Body mm mm(inch) kg(lbs) dB(A)3 Liquid Gas Drain(OD/ID) Dehumidification Rate l/h Safety devices mm(inch) mm(inch) mm Dimensions (WxHxD) Body Weight Air Filter Sound Level (H/M/L) Piping Connections cmm cfm F/Vac / V / Hz kW Btu/h kW Btu/h A
LMN(C)H126DE*0 1/ 220~240 / 50 3.52 12,000 3.52 12,000 0.22 Induction Cross Flow Fan 40 x 1 10 353 9.0 / 400 Direct Drive 2R x 15C x 20 915 x 282 x165(36.0 x 11.1 x 6.5) 9.5 (20.9) Long Life Filter 40 / 35 / 30 6.35 (1/4) 12.7 (1/2) 21.5 / 16.0 1.5
LMN(C)H186D8*0 1/ 220~240 / 50 5.28 18,000 5.28 18,000 0.28 Induction Cross Flow Fan 62 x 1 14 494 2.0 / 370 Direct Drive 2R x 15C x 20 1,107 x 299 x 200(43.6 x 11.7 x 7.8) 14.1 (31.1) Long Life Filter 40 / 37 / 34 6.35 (1/4) 12.7 (1/2) 21.5 / 16.0 2.0 Fuse, Thermal Protector for Fan Motor Thermistor
LMN(C)H246D8*0 1/ 220~240 / 50 7.03 24,000 7.03 24,000 0.35 Induction Cross Flow Fan 70 x 1 17 600 2.0 / 370 Direct Drive 2R x 15C x 20 1,107 x 299 x 200(43.6 x 11.7 x 7.8) 14.1 (31.1) Long Life Filter 44 / 40 / 37 6.35 (1/4) 15.88 (5/8) 21.5 / 16.0 2.5
New concept interior airconditionerART COOL - Innovation of new concept Golden ratio of bedroom! New shpe Interior! Altemation from general air-conditioner To grace image of room air-conditioner Bring you to new interior bedroom
Auto CleanA main cause of air conditioner odours is mould and bacteria that breed in the heat exchanger. The Auto Clean function dries the wet heat exchanger to help prevent mould and bacteria from breeding thus significantly reducing the old rag smell and saves you from frequent cleaning.
Conventional
LG Auto Clean
Temperature Sensor Referigerant Referigerant Control Connectable outdoor unit Power and transmission interunit cable (including earth) No.* mm2 R22 EEV Multi M DX 4 x 0.75 (including earth)
R22 EEV Multi M DX 4 x 0.75 (including earth)
R22 EEV Multi M DX 4 x 0.75 (including earth)
Various Color*Mirror(R) *Silver(V)
1 STEPDries the evaporator with gentle low noise air from the fan by removing any remaining moisture. Pressing the Auto Clean button will activate the automatic cleaning function after the cooling operation.
2 STEPRemoves moulds through the Neo Plasma system. Only the fan will operate to dry the inner part of the air conditioner in just 30 minutes.
Notes:1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB - Interconnecting Piping Length 7.5 m - Level Difference of Zero. 2. Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. *: See the page "Combination Table"
*Blue(B)
*Dark Wood(N)
56
57
Ceiling Cassette Type
LG AIR CONDITIONERS 2009
PLASMA Air Purifying System(Optional)LG's unique PLASMA Air Purifying System not only reduces microscopic contaminants and dust, but also filters house mites, pollen and even pet fur to ease allergy and asthma symptoms. With a filter that can be used over and over again by simply washing it, you can enjoy clean fresh air without having to worry about changing the filter every couple of years or so resulting in cost savings.
Drain leakage check
Hanger adjust
Hanger adjust
4 Vane Independent Operation: PARCUSA0Vane angle control satisfies both users who like direct wind or indirect wind.And also it prevents cold air draft. - This function can be controled with new wired remote controllerModel Decorative Panel Model Power Supply Cooling Capacity Heating Capacity Current Fan Nominal running current Motor Type Fan Type Motor Output x Number of Unit Air Flow Rate (H/M/L) Capacitor Drive Coil Row x column x FPI Decorative Panel Weight Air Filter Sound Level (H/M/L) Piping Connections Drain Dehumidification Rate Safety devices Temperature Sensor Referigerant Referigerant Control Connectable outdoor unit Power and transmission interunit cable (including earth) No.* mm2 R22 EEV (in DB Unit) Multi M DX 4 x 0.75 (including earth) R22 EEV (in DB Unit) Multi M DX 4 x 0.75 (including earth) R22 EEV (in DB Unit) Multi M DX 4 x 0.75 (including earth) Liquid Gas OD/ID dB(A)3 mm(inch) mm(inch) mm l/h Body Decorative Panel mm mm(inch) mm kg(lbs) kg(lbs) cmm cfm F/Vac /V/Hz kW Btu/h kW Btu/h A LMN(C)H12GTRA0 PT-UQC 1/ 220~240 / 50 3.52 12,000 3.52 12,000 12.6 / 12.7 BLDC Turbo fan 60 x 1 9.5 / 8.0 / 7.0 336 / 283 / 247 Direct drive 2 x 8 x 18 700 x 30 x 700 14 (30.9) 3 (6.6) Long life filter 38 / 35 / 32 6.35 (1/4) 12.7 (1/2) 32 / 25 1.2 LMN(C)H18GTQA0 PT-UQC 1/ 220 ~240/ 50 5.28 18,000 5.28 18,000 16.0 / 16.4 BLDC Turbo Fan 60 x 1 13.0 / 12.0 / 11.0 777 / 671 / 600 Direct drive 2 x 10 x 18 700 x 30 x 700 15 (33.1) 3 (6.6) Long life filter 41 / 39 / 36 6.35 (1/4) 12.7 (1/2) 32 / 25 2.4 LMN(C)H24GTPA0 PT-UMC 1/ 220~240 / 50 7.03 24,000 7.03 24,000 0.6 BLDC Turbo fan 60 x 1 17.0 / 15.0 / 13.0 600 /530 / 459 Direct drive 2 x 8 x 19 950 x 37 x 950 22.0 (48.5) 5.6 (12.3) Long Life Filter 39 / 37 / 34 6.35 (1/4) 15.88 (5/8) 32 / 25 2.0 Thermistor R22 EEV (in DB Unit) Multi M DX 4 x 0.75 (including earth) R22 EEV (in DB Unit) Multi M DX 4 x 0.75 (including earth) R22 EEV (in DB Unit) Multi M DX 4 x 0.75 (including earth) LMN(C)H30GTNA0 PT-UMC 1/ 220 ~240/ 50 8.79 30,000 8.79 30,000 0.6 BLDC Turbo Fan 124 x 1 22.0 / 19.0 / 17.0 777 / 671 / 600 Direct drive 2 x 10 x 19 950 x 37 x 950 23.5 (51.8) 5.6 (12.3) Long Life Filter 40 / 36 / 33 6.35 (1/4) 15.88 (5/8) 32 / 25 2.5 LMN(C)H36GTNA0 PT-UMC 1/ 220~240 / 50 10.55 36,000 10.55 36,000 0.6 BLDC Turbo Fan 124 x 1 25.0 / 22.0 / 19.0 883 / 777 / 671 Direct drive 2 x 10 x 19 950 x 37 x 950 23.5 (51.8) 5.6 (12.3) Long Life Filter 44 / 41 / 39 6.35 (1/4) 15.88 (5/8) 32 / 25 4.3 LMN(C)H48GTMA0 PT-UMC 1/ 220~240 / 50 14.07 48,000 14.07 48,000 0.7 BLDC Turbo Fan 124 x 1 33.0 / 29.0 / 25.0 1 165 / 1 024 / 883 Direct drive 2 x 12 x 19 950 x 37 x 950 25.6 (56.4) 5.6 (12.3) Long Life Filter 50 / 47 / 43 9.52 (3/8) 19.05 (3/4) 32 / 25 6.7
Group Control1) Basic Operation - Linking several units, one Group Control Unit can manage a number of indoor units. 2) Control Features - Through a data cable connected to each indoor unit, a group of units can be managed from the group controller. - The Group Control function is enabled by cutting an optional jump wire in the wired remote control, which prevents data collision. - One Group Control Unit can control up to 16 indoor units.1 2 ........ 16
Auto ChangeoverWith reverse cycle models,the air conditioner will switch automatically from cooling to heating modes depending on the set temperature. Initial Setting Temp :18 C: (Memory the final setting temp) Control of setting temp. Wired Remoted Controller:18~30 C Reset Button in indoor unit: finally memorized temp. Wireless Remoted Controller: 23~27
Dimensions (WxHxD) Body
570x214x570(22.4x8.4x22.4) 570x256x570(22.4x10.0x22.4) 840x204x840(33.1x8.0x33.1) 840x246x840(33.1x9.7x33.1) 840x246x840(33.1x9.7x33.1) 840x288x840(33.1x11.3x33.1)
Fuse, Thermal Protector for Fan Motor
........
Elevation Grille (Accessory :PTEGMO)Easy filter cleaning with elevation grille - Installed inside main body - Auto horizontal level - 4 points support - Memory for user s level - Max.4.5m length
Notes:1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 27C(80.6F) DB /19C(66.2F) WB - Outdoor Temperature 35C(95F) DB /24C(75.2F) WB - Interconnecting Piping Length 7.5m - Level Difference of Zero. Heating: - Indoor Temperature 20C(68F) DB / 15C(59F) WB - Outdoor Temperature 7C(44.6F) DB / 6C(42.8F) WB - Interconnecting Piping Length 7.5 m - Level Difference of Zero. 2. Capacities are Net Capacities. 3. Due to our policy of innovation some specifications may be changed without notification. 4. *: See the page "Combination Table"
High Ceiling corresponding OperationAccording to the ceiling height, the speed of the internal fan can be adjusted with a sliding switch on the back of the wired remote control unit.
4way 4.5m
Conventional 3.5m
4-Point Support Structure Auto Horizontal Control
Memory for users level
Auto bottom detection
Air Velocity Distribution
58
59
Ceiling Concealed Duct (high static pressure)
LG AIR CONDITIONERS 2009
*E.S.P: External Static PressureThe air volume and sound level is kept constant as designed regardless of changes in E.S.P.(External Static Pressure) E.S.P. technology - Optimizes Duct Installation - Keeps Capacity & Sound Levels within desired ranges - Reduces the number of models Phase control motor technology reduces installation costs. The desired air flow is obtained by adjusting the phase motor during installation of the product, giving you more flexibility when setting up your duct system. The E.S.P can be adjusted linearly from 0 to 10mmAq.
Compact & Light Design and Easy InstallationFlexible duct is easy to install Regardess of room size or heater position it can be installed even in a limited space and saves construction cost as the unit has slim thicknessCeiling Canvas Duct Intake Duct Indoor Unit Discharge Flexible Duct
Model Power SupplyCeiling Board Air Intake Port Inspection Port Air Discharging Port
LMN(C)H186BHA0 LMN(C)H246BHA0 LMN(C)H306BGA0 LMN(C)H366BGA0 LMN(C)H486BRA0 LMN(C)H126BTG0 LMN(C)H186BTG0 LMN(C)H246BYG0 / V / Hz kW Btu/h kW Btu/h Nominal running current Motor Type Fan Type Motor Output x Number of Unit Air Flow Rate (H/M/L) cmm cfm F/Vac mm mm(inch) kg(lbs) dB(A)3 Liquid Gas Drain(OD/ID) mm(inch) mm(inch) mm l/h A 1/ 220~240 / 50 5.28 18,000 5.28 18,000 0.92 Induction Sirocco Fan 118 x 1 16.5/14.5/13.0 583/512/459 8 6 / 370 Direct Drive 3R x 10C x 21 880x260x450 35(77.2) 36 / 34 / 32 6.35 (1/4) 12.7(1/2) 25.4 / 22.6 2.0 1/ 220~240 / 50 7.03 24,000 7.03 24,000 0.92 Induction Sirocco Fan 118 x 1 18.0/16.5/14.0 636/583/494 8 6 / 370 Direct Drive 3R x 10C x 21 880x260x450 35(77.2) 38 / 36 / 34 6.35 (1/4) 15.88(5/8) 25.4 / 22.6 2.5 1/ 220~240 / 50 8.79 30,000 8.79 30,000 1.42 Induction Sirocco Fan 272 x 1 26.5/23.0/20.0 936/812/706 10 6 / 370 Direct Drive 3R x 12C x 21 1,180x298x450 38(83.8) 40 / 38 / 35 6.35 (1/4) 15.88(5/8) 25.4 / 22.6 3.0 1/ 220~240 / 50 10.55 36,000 10.55 36,000 1.42 Induction Sirocco Fan 272 x 1 32.0/29.0/26.5 10 6 / 370 Direct Drive 3R x 12C x 21 1,180x298x450 38(83.8) 42 / 39 / 36 6.35 (1/4) 15.88(5/8) 25.4 / 22.6 3.5 Thermistor R22 EEV Multi M DX No.* mm2 R22 EEV Multi M DX R22 EEV Multi M DX R22 EEV Multi M DX R22 EEV Multi M DX R22 EEV Multi M DX R22 EEV Multi M DX R22 EEV Multi M DX 1/ 220~240 / 50 14.07 48,000 14.07 48,000 3.65 Induction Sirocco Fan 431 x 1 40.0/35.0/30.0 15 15 / 450 Direct Drive 3R x 13C x 19 1,230x380x590 60(132.3) 44 / 42 /30 9.52(3/8) 19.05(3/4) 25.4 / 22.6 6.0 1/ 220~240/ 50 3.52 12,000 3.52 12,000 0.31 Induction Sirocco Fan 35 x 1 10.0/9.0/8.0 352/317/282 2 2.5/400 Direct Drive 3R x 12C x 18 650x230x535 22 (48.5) 37 / 34 / 31 6.35 (1/4) 12.7(1/2) 25.4 / 22.6 1.2 1/ 220~240/ 50 5.28 18,000 5.28 18,000 0.58 Induction Sirocco Fan 47 x 1 13.5/12.0/10.0 477/424/353 2 2.5/370 Direct Drive 2R x 12C x 18 1,000x230x535 (39.4x9.0x21.1) 29 (63.9) 38 / 36 / 34 6.35 (1/4) 12.7(1/2) 25.4 / 2