lexington, kentucky 40509

4
D - W E - W F - W G - W 1 - W 2 - W 3 - W 4 - W 5 - W 6 - W 7 - W 8 - W H - W LAB 103 SOILED 108 TOILET 109 SIGN-IN 107 COMM 106 ELECTRICAL 116 MEN 102 WOMEN 104 ELEVATOR EL-A SHAFT BREAK AREA 118 CLEAN SUPPLY 121 TOILET 120 TOILET 119 NURSE STATION 110 CORRIDOR 112 INFUSION 110A INFUSION 110B INFUSION 110C INFUSION 110D INFUSION 110E INFUSION 110F INFUSION 110G INFUSION 110H INFUSION 110I INFUSION 110J INFUSION 110K INFUSION 110L STAIR ST-B STAIR ST-A ELEVATOR EL-B A-401 A 121 118 D - W E - W F - W G - W 1 - W 2 - W 3 - W 4 - W 5 - W 6 - W 7 - W 8 - W H - W A-402 A CLEAN SUPPLY 219 PHARMACY WORK / STOCK 217A COMM 229 PHARMACY DISPENSING 217 ELECTRICAL 220B TOILET 204 SOILED 228 TOILET 231 NURSE STATION 205 TOILET 216 PASSAGE 223 INFUSION 205A INFUSION 205B INFUSION 205C INFUSION 205D INFUSION 205E INFUSION 205F INFUSION 205G INFUSION 205H INFUSION 205J INFUSION 205K INFUSION 205L TRIAGE 202 PASSAGE 220 UNISEX 227 UNISEX 232 ELEVATOR EL-A SHAFT REGISTRATION 201 ELEVATOR EL-B STAIR ST-A STAIR ST-B INFUSION 203 PASSAGE 220A PASSAGE 225 219 217 RATED WALL LEGEND 1 - HOUR FIRE BARRIER 2 - HOUR FIRE BARRIER 1 - HOUR SMOKE BARRIER SPECIAL NOTE FOR FLOOR PENETRATIONS REFER TO PLUMBING & ELECTRICAL DRAWINGS. IT IS ACCEPTABLE TO CORE DRILL THROUGH THE EXISTING SLAB AS NOTED BELOW: 1. PLUMBING PENETRATIONS THROUGH THE EXISTING SLAB SHALL BE LOCATED AS DESIGNATED ON THE PLUMBING DRAWINGS. ADDITIONAL, ENLARGED, OR RELOCATED HOLES ARE NOT PERMITTED. 2. CORE HOLES AT ROOF LEADERS AT GRID L - 12 AND L - 18 MAY CUT ONE BAR SPANNING IN EITHER DIRECTION. CORE HOLES AT THESE LOCATIONS ARE LIMITED TO 10". 3. UNDAMAGED CONCRETE SHALL REMAIN BETWEEN ANY (2) CORE DRILLED HOLES. THE DISTANCE BETWEEN THE EDGES OF ANY (2) HOLES SHALL BE NO LESS THAN THE HOLE DIAMETER OF THE LARGEST HOLE. 4. CORED HOLES SHALL NOT EXCEED PIPE DIAMETER PLUS 1". 5. REINFORCING STEEL IN THE SLABS SHALL NOT BE CUT FOR ANY PENETRATIONS. USE NON - DESTRUCTIVE TESTING TO LOCATE REINFORCING STEEL PRIOR TO DRILLING HOLES. ADJUST PENETRATION LOCATION AS REQUIRED TO AVOID CUTTING REINFORCING. IF PENETRATION LOCATION CANNOT BE ALTERED, CONTACT THE ARCHITECT FOR DIRECTION BEFORE PROCEEDING. COPYRIGHT 2019 - JRA, INC. JRA ARCHITECTS HAS RETAINED AN ELECTRONIC VERSION OF THESE DRAWINGS. THE CLIENT AGREES NOT TO REUSE THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN PART, FOR ANY PURPOSE OTHER THAN FOR THE PROJECT. THE CLIENT AGREES NOT TO TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF THE ARCHITECT. THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS AGAINST THE ARCHITECT RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR REUSE OF THE ELECTRONIC FILES FOR ANY OTHER PROJECT BY ANYONE OTHER THAN THE ARCHITECT. PROJECT DATE 3225 Summit Square Place, Suite 200 Lexington, Kentucky 40509 859.252.6781 NOT FOR CONSTRUCTION REVISIONS UK PROJECT 2500.0 3/25/2019 1:34:30 PM D:\Users\kmartin\Documents\201845_CancerCenter-Arch_kmartin70.rvt A - 111 RENOVATION PLANS - WHITNEY 201845 03.25.19 PHASE 2 - DESIGN DEVELOPMENT REVIEW SUBMITTAL IMPROVE CLINICAL/AMBULATORY SERVICES - CENTER SERVICES UNIVERSITY OF KENTUCKY CAPITAL PROJECT MANAGEMENT DIVISION LEXINGTON, KY ARCHITECTURAL 3/32" = 1'-0" A WHITNEY HENDRICKSON - FIRST FLOOR OVERALL 3/32" = 1'-0" B WHITNEY HENDRICKSON - SECOND FLOOR OVERALL KEY PLAN A B C D E F WHITNEY ROACH PAV H No. Description Date

Upload: others

Post on 28-Nov-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

D-W

E-W

F-W

G-W

1-W 2-W 3-W 4-W 5-W 6-W 7-W 8-W

H-W

LAB103

SOILED108

TOILET109

SIGN-IN107

COMM106

ELECTRICAL116

MEN102 WOMEN

104ELEVATOR

EL-A

SHAFT

BREAKAREA

118

CLEANSUPPLY

121

TOILET120

TOILET119NURSE

STATION110 CORRIDOR

112

INFUSION110A

INFUSION110B

INFUSION110C

INFUSION110D

INFUSION110E INFUSION

110F INFUSION110G

INFUSION110H

INFUSION110I

INFUSION110J

INFUSION110K

INFUSION110L

STAIRST-B

STAIRST-A

ELEVATOREL-B

A-401A

121

118

D-W

E-W

F-W

G-W

1-W 2-W 3-W 4-W 5-W 6-W 7-W 8-W

H-W

A-402A

CLEANSUPPLY

219

PHARMACYWORK /STOCK

217ACOMM

229

PHARMACYDISPENSING

217ELECTRICAL

220BTOILET204

SOILED228

TOILET231

NURSESTATION

205

TOILET216

PASSAGE223

INFUSION205A

INFUSION205B

INFUSION205C

INFUSION205D

INFUSION205E

INFUSION205F

INFUSION205G

INFUSION205H

INFUSION205J

INFUSION205K

INFUSION205L

TRIAGE202

PASSAGE220

UNISEX227

UNISEX232

ELEVATOREL-A

SHAFT

REGISTRATION201

ELEVATOREL-B

STAIRST-A

STAIRST-B

INFUSION203

PASSAGE220A

PASSAGE225

219217 RATED WALL LEGEND

1 - HOUR FIRE BARRIER

2 - HOUR FIRE BARRIER

1 - HOUR SMOKE BARRIER

SPECIAL NOTE FOR FLOOR PENETRATIONS

REFER TO PLUMBING & ELECTRICAL DRAWINGS.

IT IS ACCEPTABLE TO CORE DRILL THROUGH THE EXISTING SLAB AS NOTED BELOW:

1. PLUMBING PENETRATIONS THROUGH THE EXISTING SLAB SHALL BE LOCATED AS DESIGNATED ON THE PLUMBING DRAWINGS. ADDITIONAL, ENLARGED, OR RELOCATED HOLES ARE NOT PERMITTED.

2. CORE HOLES AT ROOF LEADERS AT GRID L-12 AND L-18 MAY CUT ONE BAR SPANNING IN EITHER DIRECTION. CORE HOLES AT THESE LOCATIONS ARE LIMITED TO 10".

3. UNDAMAGED CONCRETE SHALL REMAIN BETWEEN ANY (2) CORE DRILLED HOLES. THE DISTANCE BETWEEN THE EDGES OF ANY (2) HOLES SHALL BE NO LESS THAN THE HOLE DIAMETER OF THE LARGEST HOLE.

4. CORED HOLES SHALL NOT EXCEED PIPE DIAMETER PLUS 1".5. REINFORCING STEEL IN THE SLABS SHALL NOT BE CUT FOR ANY

PENETRATIONS. USE NON-DESTRUCTIVE TESTING TO LOCATE REINFORCING STEEL PRIOR TO DRILLING HOLES. ADJUST PENETRATION LOCATION AS REQUIRED TO AVOID CUTTING REINFORCING. IF PENETRATION LOCATION CANNOT BE ALTERED, CONTACT THE ARCHITECT FOR DIRECTION BEFORE PROCEEDING.

COPYRIGHT 2019 - JRA, INC.

JRA ARCHITECTS HAS RETAINED AN ELECTRONIC VERSION OF THESE

DRAWINGS. THE CLIENT AGREES NOT TO REUSE THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN

PART, FOR ANY PURPOSE OTHER THAN FOR THE PROJECT. THE CLIENT AGREES NOT TO

TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT THE PRIOR WRITTEN

CONSENT OF THE ARCHITECT. THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS

AGAINST THE ARCHITECT RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR REUSE OF THE ELECTRONIC FILES

FOR ANY OTHER PROJECT BY ANYONE OTHER THAN THE ARCHITECT.

PROJECT

DATE

3225 Summit Square Place, Suite 200Lexington, Kentucky 40509

859.252.6781

NOT FOR CONSTRUCTION

REVISIONS

UK PROJECT 2500.0

3/25

/201

9 1:

34:3

0 PM

D:\U

sers

\km

artin

\Doc

umen

ts\2

0184

5_C

ance

rCen

ter-A

rch_

kmar

tin70

.rvt

A-111

RENOVATIONPLANS -

WHITNEY

201845

03.25.19

PHAS

E 2

- DES

IGN

DEV

ELO

PMEN

T R

EVIE

WSU

BM

ITTA

L

IMPR

OVE

CLI

NIC

AL/A

MB

ULA

TOR

Y SE

RVI

CES

-C

ENTE

R S

ERVI

CES

UN

IVER

SITY

OF

KEN

TUC

KY

CAP

ITAL

PR

OJE

CT

MAN

AGEM

ENT

DIV

ISIO

NLE

XIN

GTO

N, K

Y

ARCHITECTURAL

3/32" = 1'-0"A WHITNEY HENDRICKSON - FIRST FLOOR OVERALL 3/32" = 1'-0"B WHITNEY HENDRICKSON - SECOND FLOOR OVERALL

KEY PLAN

A

B C

DE FWHITNEY

ROACH

PAV H

No. Description Date

jesc228
Line
jesc228
Line
jesc228
Typewritten Text
105
jesc228
Typewritten Text
112
jesc228
Typewritten Text
110
jesc228
Line
jesc228
Line
jesc228
Line
jesc228
Polygonal Line
jesc228
Polygonal Line
jesc228
Polygonal Line
jesc228
Line

F

F.5 G.5 H.5

H J

J.5

K L

AR

ML.4 M.3 N P R S T U

20

19

18

17

A13

23

21

17.5

24

G

18.5

A-404A

A-405A

HX211A HX213 HX215A

HX221E

HX221F

HX221

HX221B

HX215-A

HX221D HX221C

HX215-B

HX226HX224

HS224E1

HS224F

HC203

HC205BHC205

HC205A

HC212

CORRIDORHS224

INFUSION1

HS224A

INFUSION2

HS224A1

INFUSION3

HS224B

INFUSION4

HS224B1

TEAMWORKHS224I

INFUSION12

HS222A

INFUSION11

HS222B

SOILEDUTILITYHS224N

INFUSION10

HS224M

INFUSION9

HS224L

INFUSION8

HS224K

INFUSION7

HS224JINFUSION

6HS224H

INFUSION5

HS224GPATIENTTOILETHS224F

CLEANSUPPLY /

EQUIPMENTHS224E

TRIAGE 1HS224D

PATIENTTOILETHS224C

SHAREDTRIAGEHX202A

SHAREDWAITING

HX202

SHAREDREGISTRATION

HX214

PREP/RECOVERYHX216

PATIENTTOILETHX208AOFFICE

HX204

PRECISIONTEAMWORKHX206

APHERESISHX212

PATIENTTOILETHX212A

COMMHX234A

SHAREDPATIENTTOILETHX218

SHAREDBREAKROOMHX234

HSKHX232

STAFFTOILETHX236

SHAREDEQUIPMENT

/ CLEANSUPPLYHX235

PATIENTTOILETHX233A

X-RAYEXAMHX233

CONTROLHX231

PATIENTTOILETHX229A

X-RAYEXAMHX229

X-RAYEXAMHX227

CHANGEHX225

FLUOROCHANGING

HX225A

PATIENTTOILETHX227A

SHAREDREADING

ROOMHX223

TECHWORKHX221A

PASSAGEHX221

PREP /DOSING 2HX221B

PREP /DOSING 1HX221C

CHANGINGHX221D

HOTTOILETHX221FHOT LAB

HX221E

CONTROLHX215A

CTEQUIPMENT

HX213

PET/CTSCAN 1HX215INTERVENTIONAL

CTHX211

CONTROLROOM

HX211A

STAIRST-X

STORAGEHX210

SOILEDUTILITYHX207

PATIENTTOILET

466

CORRIDORH200N2

CORRIDORH200N2

CORRIDORH200N2

CORRIDORH200N2

DUMBWAITERHZ205

LINENCHUTE

HSKH204 TRASH

CHUTEEQUIPMENT

HC201D

INFUSIONPHARMACISTS

HC201AOFFICEHC202 MECH

SHAFT

BREAKHC203 TOILET

HC203A

TOILETHC203B

PASSAGEHC209

NEGPRESSURESTORAGE /

NON-STERILEHAZ

COMOUNDINGHC212

HAZARDOUSCOMPOUNDING

HC205B

ANTEROOMHC205

NONHAZARDOUS

COMPOUNDINGHC205A

UNPACKINGHC211

MECHSHAFT

INFUSIONPHARMACISTS

HC201B

RECEIVING/TECHWORKAREA

HC201C

IDS WORKAREAHC210

PASSAGEHC209

SPECIALISTSWORKAREA

HC208A

CONFERENCEHC208

COORDINATOROFFICEHC207

HSKHC206

PASSAGEHC209

A-403A

SPECIAL NOTE FOR FLOOR PENETRATIONS

REFER TO PLUMBING & ELECTRICAL DRAWINGS.

IT IS ACCEPTABLE TO CORE DRILL THROUGH THE EXISTING SLAB AS NOTED BELOW:

1. PLUMBING PENETRATIONS THROUGH THE EXISTING SLAB SHALL BE LOCATED AS DESIGNATED ON THE PLUMBING DRAWINGS. ADDITIONAL, ENLARGED, OR RELOCATED HOLES ARE NOT PERMITTED.

2. CORE HOLES AT ROOF LEADERS AT GRID L-12 AND L-18 MAY CUT ONE BAR SPANNING IN EITHER DIRECTION. CORE HOLES AT THESE LOCATIONS ARE LIMITED TO 10".

3. UNDAMAGED CONCRETE SHALL REMAIN BETWEEN ANY (2) CORE DRILLED HOLES. THE DISTANCE BETWEEN THE EDGES OF ANY (2) HOLES SHALL BE NO LESS THAN THE HOLE DIAMETER OF THE LARGEST HOLE.

4. CORED HOLES SHALL NOT EXCEED PIPE DIAMETER PLUS 1".5. REINFORCING STEEL IN THE SLABS SHALL NOT BE CUT FOR ANY

PENETRATIONS. USE NON-DESTRUCTIVE TESTING TO LOCATE REINFORCING STEEL PRIOR TO DRILLING HOLES. ADJUST PENETRATION LOCATION AS REQUIRED TO AVOID CUTTING REINFORCING. IF PENETRATION LOCATION CANNOT BE ALTERED, CONTACT THE ARCHITECT FOR DIRECTION BEFORE PROCEEDING.

RATED WALL LEGEND

1 - HOUR FIRE BARRIER

2 - HOUR FIRE BARRIER

1 - HOUR SMOKE BARRIER

COPYRIGHT 2019 - JRA, INC.

JRA ARCHITECTS HAS RETAINED AN ELECTRONIC VERSION OF THESE

DRAWINGS. THE CLIENT AGREES NOT TO REUSE THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN

PART, FOR ANY PURPOSE OTHER THAN FOR THE PROJECT. THE CLIENT AGREES NOT TO

TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT THE PRIOR WRITTEN

CONSENT OF THE ARCHITECT. THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS

AGAINST THE ARCHITECT RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR REUSE OF THE ELECTRONIC FILES

FOR ANY OTHER PROJECT BY ANYONE OTHER THAN THE ARCHITECT.

PROJECT

DATE

3225 Summit Square Place, Suite 200Lexington, Kentucky 40509

859.252.6781

NOT FOR CONSTRUCTION

REVISIONS

UK PROJECT 2500.0

3/25

/201

9 1:

34:4

6 PM

D:\U

sers

\km

artin

\Doc

umen

ts\2

0184

5_C

ance

rCen

ter-A

rch_

kmar

tin70

.rvt

A-112

RENOVATIONPLAN - PAV H -

SECONDFLOOR

201845

03.25.19

PHAS

E 2

- DES

IGN

DEV

ELO

PMEN

T R

EVIE

WSU

BM

ITTA

L

IMPR

OVE

CLI

NIC

AL/A

MB

ULA

TOR

Y SE

RVI

CES

-C

ENTE

R S

ERVI

CES

UN

IVER

SITY

OF

KEN

TUC

KY

CAP

ITAL

PR

OJE

CT

MAN

AGEM

ENT

DIV

ISIO

NLE

XIN

GTO

N, K

Y

ARCHITECTURAL

1/8" = 1'-0"A PAV H - SECOND FLOOR OVERALLKEY PLAN

A

B C

DE FWHITNEY

ROACH

PAV H

No. Description Date

jesc228
Text Box
HS224Q
jesc228
Text Box
HS224P
jesc228
Line
jesc228
Line
jesc228
Polygonal Line
jesc228
Line
jesc228
Text Box
HC201
jesc228
Polygonal Line
jesc228
Text Box
HX212B
jesc228
Line
jesc228
Text Box
HX205
jesc228
Text Box
HX203
jesc228
Text Box
HX201
jesc228
Text Box
HX209
jesc228
Text Box
HX209A ?
jesc228
Text Box
HX2??
jesc228
Text Box
HX230
jesc228
Text Box
HX228
jesc228
Text Box
HX226
jesc228
Line
jesc228
Text Box
HX222
jesc228
Text Box
HX205A

EXAM 8CC174C

EXAM 9CC174B

EXAM 10CC174A

EXAM 11CC172

EXAM 13CC168

PROCEDURE12

CC170

TEAMWORKCC160

MENCC159

WOMENCC157

SHAFT

SHAFT

STAIRST-B

STAIRST-A

CLEANSUPPLIES

CC195

STAFFTOILETCC166

SOILEDHOLDING

CC197

INTAKE/PHLEBCC151C

EXAM 1CC188

EXAM 2CC190

EXAM 3CC192

EXAM 5CC196

INTAKEPHLEB

CONSULTCC186

INTAKEPHLEB

CONSULTCC184

INTAKEPHLEB

CONSULTCC187

EXAM 4CC194

EXAM 6CC198

EXAM 7/CONSULT

CC193

OFF-STAGECC189

TOILETCC199

RAD MEDWORKCC130

RAD EXAMCC127

RADWORK/FUTURE

EXAMCC129

COMMCC191A

STORAGECC189A1

(3) NURSECC191

ATRIUMLOBBYCC101

VESTIBULECC100G

ELEVATORC

ELEVATORB

CORRIDORCC100J CLEAN

SUPPLIESCC131

OFF-STAGECC132

EXAM 21CC136

EXAM 20CC138

EXAM 19CC142

EXAM 18CC144

CONSULTCC140

EXAM 14CC152

SOILEDCC100D1

TEAMWORKROOMCC156 EXAM 22

CC134

EQUIP.CC174

GG-R HH-R JJ-R KK-R LL-R MM-R NN-R PP-R RR-R SS-R

1-R

1.7-R

2-R

3-R

4-R

14-R

13-R

12-R

11-R

10-R

A-R

B-R

C-R

D-R

E-R

F-R

15-R

10.3-R

LL.3-R LL.7-R

E.7-R

A-406A

A-407A

CHECK-OUTCC180

CORRIDORCC100F

CORRIDORCC100D

RADIATIONMEDICINECC100C

ELEVATORLOBBYCC100A

PASSAGECC101A

MENCC105

WOMENCC104 ELEVATOR

A

RADIATIONMEDICINE

CC112

CIRCULATIONCC100E

PRACTICEMANAGER

CC189A

PATIENTCOORDINATORS

CC103

INTAKE/PHLEBCC151B

PROCEDURE15

CC150

EXAM 16CC148

EXAM 17CC146

PASSAGECC100H

TEAMWORKCC176 BREAK

ROOMCC162

SHAREDREGISTRATION

CC151A

HEMAWAITING

CC151

ELEC.CC100J1

STORAGECC158

ELEC.CC100D2

PATIENTTOILETCC154

OFFSTAGECC176A

STAFFTOILETCC164

PASSAGECC102

WAITINGCC180A

CC112A

CC113A

PASSAGECC100B

CC115

CC117

CC119

CC121

CC123

CC125

CC118

CC120

CC122

COMMCC116

CC124A

CC124

CC126

CC128

CC151C

CC100J

CC160-A

CC160-B

CC162

CC164CC166

CC151B

CC100D

CC156

CC154

CC152 CC150

CC148 CC146

CC100D1

CC144CC142

CC140

CC138 CC136 CC134CC132

CC131

CC129

CC189A

A-407B

SPECIAL NOTE FOR FLOOR PENETRATIONS

REFER TO PLUMBING & ELECTRICAL DRAWINGS.

IT IS ACCEPTABLE TO CORE DRILL THROUGH THE EXISTING SLAB AS NOTED BELOW:

1. PLUMBING PENETRATIONS THROUGH THE EXISTING SLAB SHALL BE LOCATED AS DESIGNATED ON THE PLUMBING DRAWINGS. ADDITIONAL, ENLARGED, OR RELOCATED HOLES ARE NOT PERMITTED.

2. CORE HOLES AT ROOF LEADERS AT GRID L-12 AND L-18 MAY CUT ONE BAR SPANNING IN EITHER DIRECTION. CORE HOLES AT THESE LOCATIONS ARE LIMITED TO 10".

3. UNDAMAGED CONCRETE SHALL REMAIN BETWEEN ANY (2) CORE DRILLED HOLES. THE DISTANCE BETWEEN THE EDGES OF ANY (2) HOLES SHALL BE NO LESS THAN THE HOLE DIAMETER OF THE LARGEST HOLE.

4. CORED HOLES SHALL NOT EXCEED PIPE DIAMETER PLUS 1".5. REINFORCING STEEL IN THE SLABS SHALL NOT BE CUT FOR ANY

PENETRATIONS. USE NON-DESTRUCTIVE TESTING TO LOCATE REINFORCING STEEL PRIOR TO DRILLING HOLES. ADJUST PENETRATION LOCATION AS REQUIRED TO AVOID CUTTING REINFORCING. IF PENETRATION LOCATION CANNOT BE ALTERED, CONTACT THE ARCHITECT FOR DIRECTION BEFORE PROCEEDING.

RATED WALL LEGEND

1 - HOUR FIRE BARRIER

2 - HOUR FIRE BARRIER

1 - HOUR SMOKE BARRIER

COPYRIGHT 2019 - JRA, INC.

JRA ARCHITECTS HAS RETAINED AN ELECTRONIC VERSION OF THESE

DRAWINGS. THE CLIENT AGREES NOT TO REUSE THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN

PART, FOR ANY PURPOSE OTHER THAN FOR THE PROJECT. THE CLIENT AGREES NOT TO

TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT THE PRIOR WRITTEN

CONSENT OF THE ARCHITECT. THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS

AGAINST THE ARCHITECT RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR REUSE OF THE ELECTRONIC FILES

FOR ANY OTHER PROJECT BY ANYONE OTHER THAN THE ARCHITECT.

PROJECT

DATE

3225 Summit Square Place, Suite 200Lexington, Kentucky 40509

859.252.6781

NOT FOR CONSTRUCTION

REVISIONS

UK PROJECT 2500.0

3/25

/201

9 1:

35:0

0 PM

D:\U

sers

\km

artin

\Doc

umen

ts\2

0184

5_C

ance

rCen

ter-A

rch_

kmar

tin70

.rvt

A-113

RENOVATIONPLAN - ROACH- FIRST FLOOR

201845

03.25.19

PHAS

E 2

- DES

IGN

DEV

ELO

PMEN

T R

EVIE

WSU

BM

ITTA

L

IMPR

OVE

CLI

NIC

AL/A

MB

ULA

TOR

Y SE

RVI

CES

-C

ENTE

R S

ERVI

CES

UN

IVER

SITY

OF

KEN

TUC

KY

CAP

ITAL

PR

OJE

CT

MAN

AGEM

ENT

DIV

ISIO

NLE

XIN

GTO

N, K

Y

ARCHITECTURAL

1/8" = 1'-0"A ROACH - FIRST FLOOR

KEY PLAN

A

B C

DE FWHITNEY

ROACH

PAV H

KEYNOTE LEGEND

KEY VALUE KEYNOTE DESCRIPTION

No. Description Date

jesc228
Text Box
REVIEWED WITH NO EXCEPTIONS TAKEN PREVIOUS ROOM NUMBERING REVIEW NOTES ARE INCORPORATED

PYXIS SUPPLY -LARGE

EXAM 15CC214

MEDICINECC285E

EXAM 13CC216

EXAM 10CC219

EXAM 11CC218

GG-R HH-R JJ-R KK-R LL-R MM-R NN-R PP-R RR-R SS-R

1-R

1.7-R

2-R

3-R

4-R

14-R

13-R

12-R

11-R

10-R

A-R

B-R

C-R

D-R

E-R

F-R

15-R

10.3-R

LL.3-R LL.7-R

E.7-R

A-408A

A-409A

EXAM 14CC215

ELEVATORB

ELEVATORLOBBYCC281

ELEVATORA

ENT EXAM8

CC221

EXAM 9CC220

BREAKCC230A

TEAMWORKCC233

INTAKECC265

EXAM 21CC208

EXAM 20CC209

EXAM 19CC210

EXAM 18CC211

CONSULTCC285D

TEAMWORK

CC285A

TOILETCC222B

PROCEDURE12

CC217

TOILETCC217B

EXAM 28CC201

EXAM 27CC202

EXAM 26CC203

EXAM 25CC204

EXAM 24CC205

TEAMWORK

CC284A

STORAGECC239

COMMCC264ENT EXAM

6CC223

ENT EXAM5

CC224

ENT EXAM4

CC225

ENT EXAM3

CC226

VOICE/SWALLOWEXAM 2CC227

VOICE/SWALLOWEXAM 1CC228

EXAM 7CC286B

CONSULTCC286A

STAFFTOILETCC289

CLEANSUPPLY /SCOPESCC236

SOILEDHOLDING

CC237

NURSE &PATIENTCOORD.CC241

TOILETCC243

CHECKOUT

CC250

ELEVATORC

WAITINGCC232

WORKCC227A

WORKCC228A

WORKCC226A

WORKCC225A

WORKCC224A

WORKCC221A

WORKCC219A

WORKCC220A

WORKCC218A

WORKCC217A

WORKCC216A

WORKCC215A

WORKCC214A

WORKCC213A

WORKCC212A

WORKCC211A

WORKCC210A

WORKCC209A

WORKCC208A

WORKCC205A

WORKCC204A

WORKCC203A

WORKCC202A

WORKCC201A

PROCEDURE17

CC212

EXAM 16CC213

CONSULTCC284D STORAGE

CC284B

TEAMWORKCC207

EXAM 23CC206

TOILETCC207B

STAFFTOILETCC284C

TOILETCC201B

TOILETCC212B

TOILETCC213B

TOILETCC216BSTAFF

TOILETCC285C

CONSULTCC283A

EXAM 22CC283B

CLEANSUPPLYCC254

SOILEDHOLDING

CC255

TEAMWORKCC251

COMMCC288

TOILETCC261

HSKCC238

COMMCC287

CORRIDORCC285

CORRIDORCC284

STAIRST-B

ELEC.CC263

ELEC.CC260

STORAGECC257

PRACTICEMANAGER/

RNMANAGER

CC262

STAIRST-A

CORRIDORCC282

INTAKECC234

INTAKECC235

INTAKECC266

TEAMWORKCC246

STORAGECC285B

PHLEBCC245

PHLEBCC247

VESTIBULECC230

TEAMWORKCC222

VESTIBULECC222A

VESTIBULECC207A

CORRIDORCC229

CORRIDORCC286 WAITING

CC248

CORRIDORCC283

CONNECTORCC280

CORRIDORCC282A CORRIDOR

CC282B

CC230A

CC2989

CC286A

CC286B

CC223

CC285B CC285CCC285D

CC234

CC235

CC243

CC245 CC247

CC285E

CC284D

CC265

CC266

CC284C CC284B

CC206

CC283B

CC283A

A-409B

A-408B

SPECIAL NOTE FOR FLOOR PENETRATIONS

REFER TO PLUMBING & ELECTRICAL DRAWINGS.

IT IS ACCEPTABLE TO CORE DRILL THROUGH THE EXISTING SLAB AS NOTED BELOW:

1. PLUMBING PENETRATIONS THROUGH THE EXISTING SLAB SHALL BE LOCATED AS DESIGNATED ON THE PLUMBING DRAWINGS. ADDITIONAL, ENLARGED, OR RELOCATED HOLES ARE NOT PERMITTED.

2. CORE HOLES AT ROOF LEADERS AT GRID L-12 AND L-18 MAY CUT ONE BAR SPANNING IN EITHER DIRECTION. CORE HOLES AT THESE LOCATIONS ARE LIMITED TO 10".

3. UNDAMAGED CONCRETE SHALL REMAIN BETWEEN ANY (2) CORE DRILLED HOLES. THE DISTANCE BETWEEN THE EDGES OF ANY (2) HOLES SHALL BE NO LESS THAN THE HOLE DIAMETER OF THE LARGEST HOLE.

4. CORED HOLES SHALL NOT EXCEED PIPE DIAMETER PLUS 1".5. REINFORCING STEEL IN THE SLABS SHALL NOT BE CUT FOR ANY

PENETRATIONS. USE NON-DESTRUCTIVE TESTING TO LOCATE REINFORCING STEEL PRIOR TO DRILLING HOLES. ADJUST PENETRATION LOCATION AS REQUIRED TO AVOID CUTTING REINFORCING. IF PENETRATION LOCATION CANNOT BE ALTERED, CONTACT THE ARCHITECT FOR DIRECTION BEFORE PROCEEDING.

RATED WALL LEGEND

1 - HOUR FIRE BARRIER

2 - HOUR FIRE BARRIER

1 - HOUR SMOKE BARRIER

COPYRIGHT 2019 - JRA, INC.

JRA ARCHITECTS HAS RETAINED AN ELECTRONIC VERSION OF THESE

DRAWINGS. THE CLIENT AGREES NOT TO REUSE THESE DRAWINGS - IN ELECTRONIC OR ANY OTHER FORMAT - IN WHOLE, OR IN

PART, FOR ANY PURPOSE OTHER THAN FOR THE PROJECT. THE CLIENT AGREES NOT TO

TRANSFER THESE ELECTRONIC FILES TO OTHERS WITHOUT THE PRIOR WRITTEN

CONSENT OF THE ARCHITECT. THE CLIENT FURTHER AGREES TO WAIVE ALL CLAIMS

AGAINST THE ARCHITECT RESULTING IN ANY WAY FROM ANY UNAUTHORIZED CHANGES TO OR REUSE OF THE ELECTRONIC FILES

FOR ANY OTHER PROJECT BY ANYONE OTHER THAN THE ARCHITECT.

PROJECT

DATE

3225 Summit Square Place, Suite 200Lexington, Kentucky 40509

859.252.6781

NOT FOR CONSTRUCTION

REVISIONS

UK PROJECT 2500.0

3/25

/201

9 1:

35:2

0 PM

D:\U

sers

\km

artin

\Doc

umen

ts\2

0184

5_C

ance

rCen

ter-A

rch_

kmar

tin70

.rvt

A-114

RENOVATIONPLAN - ROACH

- SECONDFLOOR

201845

03.25.19

PHAS

E 2

- DES

IGN

DEV

ELO

PMEN

T R

EVIE

WSU

BM

ITTA

L

IMPR

OVE

CLI

NIC

AL/A

MB

ULA

TOR

Y SE

RVI

CES

-C

ENTE

R S

ERVI

CES

UN

IVER

SITY

OF

KEN

TUC

KY

CAP

ITAL

PR

OJE

CT

MAN

AGEM

ENT

DIV

ISIO

NLE

XIN

GTO

N, K

Y

ARCHITECTURAL

1/8" = 1'-0"A ROACH - SECOND FLOOR

KEY PLAN

A

B C

DE FWHITNEY

ROACH

PAV H

KEYNOTE LEGEND

KEY VALUE KEYNOTE DESCRIPTION

No. Description Date

jesc228
Text Box
REVIEWED WITH NO EXCEPTIONS TAKEN, comments attached in email Previous room numbering review notes have been considered