Applied Technology
Abstract This white paper examines the performance considerations of placing Oracle Databases on enterprise flash drives versus conventional hard disk drives, as well as discusses the best practices for placing partial database contain-ers on flash drives.
Dell Inc. April 2009 Visit www.Dell.com/emc for more information on Dell/EMC Storage. Copyright © 2009 Dell Inc. THIS WHITE PAPER IS FOR INFORMA-TIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ER-RORS AND TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS OR IMPLIED WARRANTIES OF ANY KIND.
Leveraging
Dell | EMC CX4
with Enterprise
Flash Drives for
Oracle®
Database
Deployments
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 2
Table of Contents
Executive Summary ............................................................................................ 3
Introduction ......................................................................................................... 4
Audience ...................................................................................................................................... 4
Technology Overview ......................................................................................... 4
Dell/EMC CX4 Family of Arrays ................................................................................................... 4
Oracle Databases and Enterprise Flash Drives................................................ 5
Database workloads that are the best fit for EFDs ...................................................................... 5
Analyzing the Oracle AWR Report or Statspack Report ............................................................. 6
Load Profile Section ................................................................................................................. 6 Oracle Wait Events ................................................................................................................... 7 Tablespace I/O Stats ................................................................................................................ 8
Use Case Comparison ........................................................................................ 8
Use Case #1: Extremely Read Intensive Workload ..................................................................... 8
Use Case #2: Oracle OLTP Workload Comparison .................................................................. 11
Use Case #3: Short-stroked Oracle OLTP Workload ................................................................ 12
Use Case #4: Moving Partial Database to EFDs ....................................................................... 15
Redo Logs on EFDs? (or not) ................................................................................................ 15 Oracle TEMP tablespace on EFDs ........................................................................................ 15 Moving high Object Intensity objects to EFDs ........................................................................ 15
EFDs and an Information Lifecycle Management (ILM) Strategy .................. 19
Conclusion ........................................................................................................ 20
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 3
Executive Summary One of the major new features in the Dell/EMC CX4 family of arrays is the availability of enterprise flash
drives (EFD). The CX4 series is one of the first midrange arrays with support for this emerging generation
of data storage device. With this capability, Dell/EMC creates a new ultra-performing “Tier 0” storage that
helps remove the performance limitations of magnetic disk drives. By combining enterprise-class flash
drives and advanced Dell/EMC functionality, organizations now have a new tier of storage previously
unavailable in a midrange storage platform.
Enterprise flash drives are designed to dramatically increase the performance of latency sensitive
applications. Enterprise flash drives, also known as solid state drives (SSD), contain no moving parts and
appear as standard drives to existing CX4 management tools, allowing administrators to manage Tier 0
without special processes or custom tools or extra training. Tier 0 EFDs are ideally suited for applications
with high transaction rates and those requiring the fastest possible retrieval and storage of data, such as
currency exchange and electronic trading systems, or real-time data acquisition and processing. They also
can prove to be extremely good for highly read-intensive workloads like search engine databases. The
EFDs are designed to deliver millisecond application response times and up to 30 times more I/O
operations per second (IOPS) than traditional Fibre Channel hard disk drives. Additionally, EFDs consume
significantly less energy per IOPS than traditional hard disk drives, providing the opportunity for
significantly increased TCO by reducing the data center energy and space footprints.
Database performance has long been constrained by the I/O capability of hard disk drives (HDD), and the
performance of the HDD has been limited by intrinsic mechanical delays of head seek and rotational
latency. EFDs, however, have no moving parts and therefore no seek or rotational latency delays, which
dramatically improves their ability to sustain very high number of IOPS with very low overall response
times.
Figure 1 shows the theoretical IOPS rates that can be sustained by traditional HDD based on average seek
and latency times as compared to EFD technology. Over the past 25 years, the rotational speeds of HDDs
have improved from 3,600 rpm to 15,000 rpm, yielding only four times the improvement in IOPS when the
rest of the computer technologies like CPU speeds saw double digit growth. EFD technology represents a
significant leap in performance and may sustain up to 30 times the IOPS of traditional HDD technology.
Figure 1. Relative IOPS of various drive technologies
The performance benefits of EFD depend on the IO characteristics in real world workloads into which they
are deployed. This whitepaper discusses the benefits and best practices for deploying EFD in Oracle
database environments.
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 4
The introduction of enterprise flash drives into the Dell/EMC CX4 storage arrays helps enable these disk
arrays to meet the growing demand for higher transaction rates and faster response times. Companies with
stringent latency requirements may no longer have to purchase large numbers of the fastest Fibre Channel
disk drives and only utilize a small portion of their capacity (known as short stroking) to satisfy the IOPS
performance requirements of very demanding random workloads.
Relational databases are often at the core of business applications. Increasing their performance, while
keeping storage power consumption and footprint to a minimum, can significantly reduce the total cost of
ownership (TCO) and help to alleviate growing data centers constraints. The deployment of Tier 0 EFDs
together with slower, higher capacity tiers such as Fibre Channel and SATA drives helps enable users to
structure the application data layout where each tier of storage meets the I/O demands of the application
data it hosts.
Introduction This white paper examines some of the use cases and best practices for using enterprise flash drives with
Oracle Database workloads. Proper use of EFDs can deliver vastly increased performance to the database
application when compared to traditional Fibre Channel drives, both in transaction rates per minute as well
as transaction response time. Recommendations for identifying the right database components to place on
EFDs, consistent with Oracle engineering’s finding, are also covered in this paper.
Audience This white paper is intended for Oracle Database administrators, storage architects, customers, and
Dell/EMC field personnel who want to understand the implementation of enterprise flash drives in Oracle
Database environments to improve the performance of business applications.
Technology Overview
Dell/EMC CX4 Family of Arrays The Dell/EMC CX4 series with UltraFlex
TM technology is based on a new, breakthrough architecture and
extensive technological innovation, providing a midrange storage solution that is highly flexible and
scalable. The CX4 is the fourth-generation CX series, and continues Dell’s commitment to maximizing
customer’s investments in Dell/EMC technology by helping to ensure that existing resources and capital
assets are optimally utilized as customers adopt new technology.
The new Dell/EMC CX4 systems, as shown in Figure 2, are the next generation in the CX series. The CX4
delivers immediate support for the latest generation of disk drive technologies, such as EFDs, 4 Gb/s FC
drives for high performance, and SATA II drives for high capacity. Dell/EMC CX4 is one of the first
midrange storage systems that can support all of these latest generations of disk drive technologies.
Dell/EMC CX4 with the latest release of FLARE
® (R28) has been designed to optimize for maximum
performance and tiered storage functional flexibility.
A few major features of the Dell/EMC CX4 series are listed in Figure 2. Enterprise flash drives are
supported on all four models of Dell/EMC CX4 listed here.
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 5
Figure 2. Dell/EMC CX4 models
The enterprise-class flash drives supported by Dell/EMC CX4 are constructed with nonvolatile
semiconductor NAND flash memory and are packaged in a standard 3.5-inch disk drive form factor used in
existing Dell/EMC disk drive array enclosures. These drives are especially well suited for latency sensitive
applications that require consistently low read/write response times. EFDs also benefit from the advanced
capabilities that CX4 software provides, including local and remote replication, Navisphere® Quality of
Service Management, and five 9s availability.
Oracle Databases and Enterprise Flash Drives
Database workloads that are the best fit for EFDs There are no simple, definitive rules that would readily identify applications that best suit the EFDs, but we
can follow some guidelines. It is very important to understand the load profile of an application before
putting it on the EFDs, taking into consideration the fact that most databases have different workload
profiles during different times of the day. The EFDs are suitable for highly read intensive and extremely
latency sensitive applications and using these drives against the wrong target may not yield the desired
benefit for the investment. It is important to understand the following terminology to help with deciding
whether the EFDs are suitable for certain workloads.
Write cache: Most of the storage systems have big write side cache and all write IOPS from a host are
generally written to cache and incur no delay due to physical disk access. Dell/EMC storage arrays
have write caches sized to match the disk count supported by the controller and support enabling and
disabling write cache at the LUN level, if needed.
Read hit: A read request from a database host can be served by storage system immediately if it
already exists in storage cache because of a recent read or write or due to prefetch. A read serviced
from the storage cache without causing disk access is called a read hit. If the requested data is not
available in storage cache, the array must retrieve it from disk; this is referred to as a read miss.
CAPABILITY
SE
RV
ICE
LE
VE
LS
• 5 to 480 Drives
• 16GB memory
• 10 UltraFlex modules
• Enterprise Flash Drives
• FC & iSCSI
• 5 to 960 Drives
• 32GB memory
• 12 UltraFlex modules
• Enterprise Flash Drives
• FC & iSCSI
• 4 to 60 Drives
• 2 GB cache
• 4 x FC or iSCSI
• SAS/SATA disks
CX4-960
CX4-480
• 5 to 240 Drives
• 8GB memory
• 8 UltraFlex modules
• Enterprise Flash Drives
• FC & iSCSI
CX4-240
AX4• 5 to 120 Drives
• 6GB memory
• 6 UltraFlex modules
• Enterprise Flash Drives
• FC & iSCSI
CX4-120
Dell/EMC CX4
Family of Storage Arrays
38Dell Confidential – For NDA Use Only
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 6
Short-stroked drives: Some extremely latency sensitive applications use this technique on regular
Fibre Channel drives to obtain low latencies. This is a technique where data is laid out on many
partially populated disks in order to reduce the spindle head movement to provide high IOPS at a very
low latency.
Workloads with high cache read-hit rates are already serviced at memory access speed, and deploying them
on flash drive technology may not show a significant benefit. Workloads with low cache read-hit rates that
exhibit random I/O patterns, with small I/O requests of up to 16 KB, and that require high transaction
throughput will benefit most from the low latency of EFDs.
Database and application managers can easily point to mission-critical applications that directly improve
business revenue and productivity when business transaction throughput is increased, along with reduced
service latencies. Cognizant of these applications, storage administrators would often resort to “short
stroking” more drives to ensure the highest possible I/O service level supported for them. EFDs can provide
two very important benefits for such applications.
A single EFD can replace many short-stroked drives by its ability to provide a very high transaction
rate (IOPS). This reduces the total number of drives needed for the application, increases power saving
by not having to keep many spinning disks, and may reduce floor space in the data center as well.
EFDs provide very low latency, so applications where predictable low response time is critical and not
all the data can be kept at the host or Dell/EMC cache may benefit from using such drives. Because of
the absence of rotating media in EFDs, their transfer rate is extremely high and data can be served
much faster than the best response time that can be achieved even with a large number of short-stroked
hard drives.
The Oracle workload load profile obtained by using either the Oracle tool called Statspack or the AWR
report can be used to determine the potential for placing either the entire database or parts of it on EFDs.
These tools are two variants of the same fundamental measurement technique that monitors the Oracle level
performance counters. The AWR is supported on the later versions of the Oracle Database (10g and 11g)
where as Statspack existed since Oracle8i. Both these tools are delta-based tools, which sample the Oracle
performance counters at two different time intervals and calculate the average performance metrics based
on the total elapsed time between samples. Collecting the samples over a long interval can dilute the
average values. So, the tool should be run during the busiest time of the database application over a short
period (typically 30-minute samples are good enough). Some experienced DBAs may resort to directly
using the underlying Oracle V$ views used by these tools to obtain performance metrics dynamically, and
more on a real-time basis, instead of using these tools.
Analyzing the Oracle AWR Report or Statspack Report Various sections of the performance reports can be used to identify the workload profile. This section
describes each area of interest and what to look for in those areas.
Load Profile Section
This section defines the overall workload profile during the sampling interval. The key parameters to
identify here are Logical reads, Physical reads, and Physical writes.
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 7
Table 1. Workload profile
Per Second Per Transaction Per Exec Per Call
DB Time(s): 68.8 46.4 0.22 0.23
DB CPU(s): 2.5 1.7 0.01 0.01
Redo size: 4,256.8 2,875.4
Logical reads: 18,421.9 12,443.7
Block changes: 13.5 9.1
Physical reads: 17,459.4 11,793.6
Physical writes: 2.1 1.4
User calls: 302.3 204.2
Parses: 5.7 3.8
Hard parses: 0.3 0.2
W/A MB processed: 45,301.9 30,600.7
Logons: 0.2 0.1
Executes: 307.3 207.6
Rollbacks: 0.0 0.0
Transactions: 1.5
A read intensive workload is one where a significant number of reads are physical (reads served from
storage rather than Oracle cache) as reported in the AWR. This workload will typically benefit the most by
leveraging EFDs. It is important, however, to determine if these IOPS can be reduced by simply tuning the
database cache before exploring the EFD alternative. It is much easier to increase the memory in the system
or increase Oracle buffer cache as opposed to throwing EFDs at the problem.
The Buffer Pool Advisory section of the Oracle performance report indicates the impact of increasing the
database buffer cache. In the current example, the database was configured to use 4 GB of buffer cache;
Table 2 indicates that even when the buffer pool is doubled the Estimated Physical Reads remain the same.
This is an example where the improvement can only be obtained by having faster storage and hence an
ideal candidate for EFDs.
Table 2. Buffer Pool Advisory
P Size for Est (M)
Size Factor Buffers for Estimate
Est Phys Read Factor
Estimated Physical Reads
D 384 0.09 47,340 1.49 897,413
D 1,152 0.28 142,020 1.06 635,008
D 1,920 0.47 236,700 1.01 603,605
D 3,456 0.84 426,060 1.00 600,590
D 4,096 1.00 504,960 1.00 600,590
D 4,608 1.13 568,080 1.00 600,590
D 5,376 1.31 662,760 1.00 600,590
D 6,144 1.50 757,440 1.00 600,590
D 6,912 1.69 852,120 1.00 600,590
D 7,680 1.88 946,800 1.00 600,590
Even doubling database cache will result in the same amount of physical reads
Oracle Wait Events
This section indicates the top five Oracle foreground wait events. Most DBAs concentrate on this section
when they tune their databases as these are the low hanging fruits that return the maximum benefit for their
tuning effort. The key parameter to identify in this section is the “db file sequential read” wait event. The
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 8
name of the parameter is counter-intuitive as it actually indicates the random nature of the workload rather
than what its name implies. This event tracks how many times the database had to wait for single block I/O
to finish during the sampling interval and its average wait time. In the following example, the database was
spending around 88% of the time for an I/O to finish with an average wait time of 14 ms. Placing this
database on EFDs may significantly improve the average latency if the application users are complaining
about slow responsiveness of the system. A higher latency value here does not always indicate a problem.
Ultimately, it is the actual user experience that decides if the overall business transaction service
performance is acceptable.
Table 3. Top 5 Timed Foreground Events
Event Waits Time(s) Avg wait (ms) % DB time Wait Class
db file sequential read 1,169,805 16,171 14 87.92 User I/O
db file parallel read 34,303 1,819 53 9.89 User I/O
DB CPU 290 1.58
log file sync 79,538 54 1 0.29 Commit
db file scattered read 1,997 27 14 0.15 User I/O
Tablespace I/O Stats
Two more sections toward the end of report provide I/O statistics at the data container level, which can be
used for identifying right migration targets to EFDs. The first is called “Tablespace I/O stats” and the
second is “File I/O stats.” The entries at the top of these tables (with the highest I/O rate) will provide the
maximum benefit by migrating to EFDs. Data containers with higher average response times are likely
good candidates for moving to EFDs. These can be data files, index, temp, and so on. This approach
provides an alternative for moving the whole database to EFDs. Keep in mind that these reported numbers
are averages, and do not necessarily reflect bursts of I/O activities on the tablespaces, which may in fact
spike to significantly higher values for certain periods within the sampling interval.
Table 4. Tablespace I/O stats
Tablespace Reads Av Reads/s
Av Rd(ms)
Av Blks/Rd
Writes Av Writes/s
Buffer Waits
Av Buf Wt(ms)
DATA1 4,464,451 4,730 19.11 1.00 1,440,601 1,526 347 47.20
DATA2 454,647 482 11.05 1.03 288,654 306 142 10.35
DATA3 425,990 451 17.80 1.00 186,795 198 48 2.71
INDEX1 265,040 281 10.30 1.09 234,963 249 14 10.00
INDEX2 188,572 200 15.07 1.03 168,047 178 3 3.33
Use Case Comparison The following are different use case scenarios that had been tested by EMC engineering, demonstrating
how properly leveraging EFDs may decidedly benefit these typical business deployments. Please note that
all the tests in this paper were comparing 73GB EFDs with 300 GB 15k rpm FC drives and were done on a
CX4-960 running FLARE release 28.
Use Case #1: Extremely Read Intensive Workload The following use case documents the improvement the EFDs may bring to a highly read intensive and
latency sensitive application. It is common practice to deploy these kinds of applications on a huge number
of short-stroked Fibre Channel spindles. This particular application was deployed on 150 Fibre Channel
spindles to meet the very low latency requirement, and still was able to achieve only 4 ms latency. This use
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 9
case shows how the same application can be deployed on a fewer EFDs, resulting in more transactions and
better latency. The following is the beginning of an AWR report (10 minutes sample). The environment
was Oracle Database 11g/ASM/Oracle Enterprise Linux with a Dell/EMC CX4-960.
Table 5. Results of Use Case #1
Cache sizes
Begin End
Buffer Cache: 4,096M 4,096M Std Block Size: 8K
Shared Pool Size: 640M 640M Log Buffer: 41,488K
Load profile
Per Second
Redo size: 4,256.8
Logical reads: 18,421.9
Block changes: 13.5
Physical reads: 17,459.4
Physical writes: 2.1
User calls: 302.3
Executes: 307.3
Transactions: 1.5
Instance efficiency percentages (target 100%)
Buffer Nowait %: 100.00 Redo NoWait %: 100.00
Buffer Hit %: 50.88 In-memory Sort %: 100.00
Library Hit %: 86.13 Soft Parse %: 95.64
Execute to Parse %: 98.16 Latch Hit %: 99.99
50% of I/Os are served from storage, but Buffer Pool Advisory indicates no help from increasing buffer cache
Top 5 Timed Events
Event Waits Time(s) Avg Wait(ms) % Total Call Time
Wait Class
db file sequential read 10,803,192 42,450 4 95.92 User I/O
DB CPU 1,575 3.56
db file scattered read 32,266 219 7 0.50 User I/O
control file sequential read 25,993 7 0 0.02 System I/O
db file parallel read 704 5 7 0.01 User I/O
The top wait event (at 96%) is random reads with 4 ms response time. This application is latency sensitive and requires a huge number of Fibre Channel drives. It may highly benefit by use of flash
drives.
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 10
The next tables show Oracle workload profiles after moving the data on to just six EFDs.
Table 6. Results of Use Case #1 after moving the database to six EFDs
Cache sizes
Begin End
Buffer Cache: 4,096M 4,096M Std Block Size: 8K
Shared Pool Size: 640M 640M Log Buffer: 41,488K
Load profile
Per Second
Redo size: 6,564.8
Logical reads: 57,548.5
Block changes: 27.2
Physical reads: 53,055.7
Physical writes: 3.6
User calls: 937.8
Executes: 944.3
Transactions: 2.4
Instance efficiency percentages (target 100%)
Buffer Nowait %: 100.00 Redo NoWait %: 100.00
Buffer Hit %: 75.53 In-memory Sort %: 100.00
Library Hit %: 88.20 Soft Parse %: 96.58
Execute to Parse %: 99.21 Latch Hit %: 99.97
Top 5 Timed Events
Event Waits Time(s) Avg Wait(ms)
% Total Call Time
Wait Class
db file sequential read 33,689,960 40,945 1 87.76 User I/O
DB CPU 5,631 12.07
db file scattered read 30,079 60 2 0.13 User I/O
control file sequential read 25,993 6 0 0.01 System I/O
latch free 6,621 5 1 0.01 Other
The response time dropped from 4 ms to 1 ms even with 96% fewer disks
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 11
This test clearly shows the significant improvement a few EFDs may bring to enterprise applications. The
overall improvement in this case is well beyond the 30x promised by EFDs considering the 25x difference
in spindle count and more than 3x improvement in the overall transaction throughput. On top of the
performance gains, there also exists the potential to dramatically decrease the amount of power and tile-
space required in the data center in this case.
Table 7. EFDs over FC drives with Use Case #1
Metric 150 FC drives 6 EFDs
Physical reads 17,459 53,055
Read latency 4 ms 1 ms
Managed business information explosion in the Internet age has created the new demand for powerful
search engines that can effectively process vast volumes of accumulated business data. Enterprise flash
drives may be a good fit into this market segment because of their characteristics.
Use Case #2: Oracle OLTP Workload Comparison EFDs are extremely good for highly read intensive applications and are impressive even using uncached
RAID 5 for applications with a read-write mix that favor writes. In either case they may provide good total
cost of ownership (TCO) because of the other potential benefits they bring, such as significant reduction in
energy costs and significant improvements in latency along with the performance benefits. A typical OLTP
Oracle application will have some write activity because of DML operations like updates and inserts.
To compare the performance of EFDs with hard disk drives in OLTP environments, identical Oracle
Database 11g on ASM were deployed onto two separate RAID 5 (5+1) groups created of 6 x 73 GB EFDs,
and 6 x 300 GB 15k rpm Fibre Channel drives. An OLTP workload with a 60/40 read/write ratio was used
to generate identical workloads against both databases with a 64-bit Oracle Enterprise Linux server driving
the activity. The storage controller level read cache was turned off to keep the test realistic because of the
smaller database size used in this experiment. It is important to note that the read/write ratio used in this
test reflects a worst-case OLTP scenario as most of the OLTP databases have a read to write ratio of 90:10.
Figure 3. Transactions per minute comparison of EFD vs. HDD
Transactions per min - Flash vs. HDD
0
5000
10000
15000
20000
25000
0:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00
Time
Flash Tx/min HDD Tx/min
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 12
As Figure 3 shows, in the configuration used for the test, the EFDs sustained an average of 19,000
transactions per minute (TPM) and the Fibre Channel drives sustained only around 2,400 TPM, roughly an
eight-fold improvement in sustained TPM over Fibre Channel drives. In addition it is interesting to note
that the response time on the EFDs was also one-seventh of that observed on Fibre Channel drives.
This use case points to an important fact that changing only the disks in the configuration may result in a
significant improvement in IOPS and response time. However, with any tuning effort it is extremely
important to understand the real issue with the application. Improving just the I/O by a factor of X may not
always result in a multi-fold improvement in overall system response. Often times, the storage bottleneck
has been simply removed to uncover another bottleneck somewhere else. The overall improvement in the
application will be related to how badly it was impacted by the storage bottleneck that was just removed by
moving to EFDs.
Use Case #3: Short-stroked Oracle OLTP Workload
While Use Case #2 shows the performance benefits of EFDs in an apples-to-apples scenario, oftentimes
DBAs and storage architects may not replace Fibre Channel drives with an equal number of EFDs.
Moreover, Use Case #2 was done under the most ideal conditions where the entire storage array was
running just one workload and also was using the non-standard cache settings. It is very common in
production environments to share the storage array with several different applications. To understand the
performance of EFDs in the real-world environment, a background load was added to the tests, which
drove the storage processors constantly to a 40% to 45% usage and kept the caches saturated. An OLTP
workload with 60/40 real/write mix was now run on this system under load against two sets of heavily
short-stroked 75 X 300 GB Fibre Channel drives versus a 6 X 73 GB EFD setup. The following cache
settings were used, which are the default settings.
Table 8. Cache settings (default)
SP read cache SP write cache LUN read cache LUN write cache
75 FC ON ON ON ON
6 EFD ON ON OFF OFF
Figure 4. Relative transactions per minute comparison of 6 EFDs vs. 75 FC drives
The overall improvement from EFDs can be calculated by the following formula as the spindle count is
changing between runs.
Relative Transactions per minute
1.00
0.65
0.00
0.20
0.40
0.60
0.80
1.00
1.20
75 FCD 6 EFD
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 13
Overall Improvement = Disk reduction factor * Performance improvement factor
Overall Improvement = (75 / 6) * 0.65 ~= 8 times
Figure 4 shows that, even under these extreme conditions, EFDs delivered an overall improvement of
800%, which is extremely good given the extra savings in the form of data center energy and tile space
these EFDs can deliver. A deep analysis of the performance data from this run reveals that the uncached
EFD LUNs were causing unnecessary Oracle “logfile sync” wait-events, resulting in relatively fewer
transactions and underutilization of EFDs. Adhering to Oracle’s recommendations regarding the placement
of redo log files, they were moved back to a separate set of Fibre Channel spindles in the next run.
Figure 5 shows that with redo logs on their separate Fibre Channel drives, EFDs delivered an impressive
overall improvement of 1,200%. This test also confirms Oracle’s recommendation about redo files
movement to EFDs (covered in the next section). It is better to leave the Oracle redo log files on cache
backed Fibre Channel drives rather than move to EFDs.
Overall Improvement = (75 / 6) * 0.98 ~= 12 times
Figure 5. Relative transactions per minute comparison of 6 EFDs vs. 75 FC drives
The performance can further be improved by turning on the write cache for the EFD LUNs. This is a non-
standard setting as the default recommendation is to turn off the write and read caches on EFD LUNs for
the following two reasons:
EFDs are extremely fast, so when the read cache is enabled for the LUNs residing on them, the read
cache lookup for each read request adds a significantly higher overhead as compared to FC drives, in
an application profile that is not expected to get many read cache hits at any rate. Thus it is faster to
directly read the block from the EFD.
Relative Transactions per minute (with logs on separate FC drives)
1.00 0.98
0.00
0.20
0.40
0.60
0.80
1.00
1.20
75 FCD 6 EFD
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 14
In a real-world scenario, where the CX4 is being shared by several applications and, especially,
deployed with slower SATA drives, the write cache may become fully saturated, placing the EFDs in a
force flush situation, which adds latency. In these situations, it is better to write the block directly to
EFDs than to the write cache of the storage system.
Even though the standard recommendation is not to enable caches for the LUNs residing on EFDs, the
DBAs and storage administrators can still choose to enable write cache for the LUNs residing on EFDs if
they are aware of the implications. This may help them to get the maximum benefit from EFDs in some
dedicated environments where the storage system is not shared across many applications. A careful analysis
and benchmarking are highly recommended before deviating from the default settings.
Figure 6 shows that, when the entire database including the redo logs was deployed on EFDs with write
cache enabled, the system delivered almost 1,700% improvement. The following cache settings were used
during this experiment.
Table 9. Cache settings
SP read cache SP write cache LUN read cache LUN write cache
75 FC ON ON ON ON
6 EFD ON ON OFF ON
Figure 6. Relative transactions per minute comparison of 6 EFDs vs. 75 FC drives
Overall Improvement = (75 / 6) * 1.35 ~= 17 times
The huge improvement obtained by just enabling write cache on for the EFDs cannot be guaranteed for
every application. It is heavily dependent on the nature of the application and its data access patterns. The
benchmark used in this study resulted in significant improvements not just because of writes to cache but
also because of write cache re-hits and reads from the write cache that may not exist with every real-world
workload.
Relative Transaction per minute (with write cache on for EFD LUNS)
1.00
1.35
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
75 FCD 6 EFD
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 15
Use Case #4: Moving Partial Database to EFDs It is always a good idea to move the entire database to EFDs if possible; however, sometimes it may not be
economically viable to move the entire database because of constraints like size of the database. This
section discusses the methods to identify the parts of the database that will yield the most benefit when
moved to EFDs. The following Oracle guidelines can be used to help with the data movement decisions.
Table 10. Oracle flash drive recommendations (from Oracle Openworld 2008 presentation)
EFD-friendly DB workloads Not as cost-effective on EFD
Random reads
B-Tree leaf access
ROWID look up into Table
Access to out-of-line LOB
Access to overflowed row
Index scan over Unclustered Table
Compression: Increases I/O intensity (IOPS/GB)
Serial reads
Random writes
Row update by PK
Index maintenance
Reduce checkpoint interval
TEMP: Sort areas and Intermediate tables
Sequentially read and written but I/O done in 1 MB units: not enough to amortize seeks
Lower Latency: Get In, Get Out
Redo log files
Sequentially read and written and commit
latency already handled by cache in storage controller
Undo table space
Sequentially written, randomly read by flashBack. But reads are for recently written data that is likely to still be in the buffer cache
Large table scans
Buffer pools with lots of writes
Mismatch between read and write latency characteristics of EFDs can cause unwanted “Free Buffer Waits”. Buffer pool tuning is necessary after deploying EFDs
Redo Logs on EFDs? (or not)
It is a common misconception that Oracle online redo logs will benefit by moving them on EFDs, whereas
all the experimental data indicates the opposite position. Testing has shown that moving redo logs on to
EFDs results in a low percentage of improvement. It is better to leave them on the write cache backed Fibre
Channel drives rather than moving them on to EFDs, thereby using EFDs for other read intensive parts of
the database like indexes or data.
Oracle TEMP tablespace on EFDs
Oracle uses this space mainly for data aggregations and sorting. When the database engine cannot fit the
sorts in memory, they will be spilled on to disk for storing intermediary results. Oracle typically does large
sequential I/Os against these tablespaces in the context of single user. When multiple users are performing
concurrent sorts on these tablespaces, the I/O turns out to be largely random in nature. Even though EFDs
do not provide as much benefit for large random I/O as they provide to small random operations, still they
are far ahead of what regular rotation Fibre Channel drives can deliver. Depending on the availability of
space on EFDs, Oracle applications will be benefited by moving the temporary tablespaces to them.
Temporary tablespace files should only be moved to EFDs after all the I/O intensive parts have been moved
to them.
Moving high Object Intensity objects to EFDs
Oracle defines a parameter called “Object Intensity” (OI) to help identify the right database objects to move
to EFDs. These objects could be Oracle tablespaces, data files, indexes, and so on. This parameter simply
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 16
defines the relative IOPS received by a given object compared to its size. Moving these objects to EFDs
makes sense as these objects get accessed frequently thereby significantly improving the latency.
Object Intensity (OI) = Object-IOPS / Object-GB
To study the performance impact of moving data containers with high Object Intensity, a bigger 1 TB
database was created on 45 x 15k rpm Fibre Channel spindles. The Object instance analysis was done after
the baseline run to identify the potential migration candidates to EFDs. The initial observation of the
Tablespace I/O stats table reveals that TABLE1, which occupies 30% of the database size and receives
about 70% of the I/O, should receive the maximum benefit by moving to EFDs.
Table 11. Tablespace I/O stats
Tablespace Reads Av Reads/s
Av Rd(ms)
Av Blks/Rd
Writes Av Writes/s
Buffer Waits
Av Buf Wt(ms)
TABLE1 4,464,451 4,730 19.11 1.00 1,440,601 1,526 347 47.20
TABLE2 454,647 482 11.05 1.03 288,654 306 142 10.35
TABLE3 425,990 451 17.80 1.00 186,795 198 48 2.71
TABLE4 265,040 281 10.30 1.09 234,963 249 14 10.00
INDEX1 188,572 200 15.07 1.03 168,047 178 3 3.33
INDEX2 222,456 236 10.85 1.00 128,160 136 1 20.00
The Object Intensity for all these objects is as shown in Table 12. A close observation of the Object
Intensity table reveals that TABLE4 receives a large number of IOPS per GB of size compared to
TABLE1. By moving these objects with high Object Intensity to EFDs, a secondary cache equivalent is
created for these objects, thereby speeding up their access. The relative benefits realized by moving the top
three items in this table should be more compared to any other data container considering the size of the
objects. Moving bigger objects to EFDs would require more drives, resulting in more investment to be
made in EFDs. The Object Intensity approach may significantly reduce the amount of data to be moved to
EFDs while providing the maximum performance benefit, thereby reducing overall EFD investment. It is
important to note that the top three entries in Table 12 do not even occupy 2% of the database.
Table 12. OI ratios
Tablespace Av Reads/s Av Writes/s Total I/O Object size (GB) OI ratio
TABLE4 258 196 454 0.343 752.19
INDEX2 238 123 361 1.75 136.00
INDEX1 203 180 383 3.35 60.60
TABLE1 4,727 1,539 6,266 109 43.37
TABLE2 494 314 808 52 9.50
TABLE3 463 208 671 91 5.09
In an ideal tiered Oracle deployment, the objects with very high Object Intensity should be placed on EFDs,
those with moderate Object Intensity should be placed on Fibre Channel drives, and finally objects with the
least Object Intensity value should be placed on SATA drives.
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 17
Figure 7 shows performance improvements that partial database movements to EFDs can bring. Various
parts of the database from a 1 TB OLTP database deployed on 45 x 15k rpm Fibre Channel spindles were
moved individually to ASM disk groups created on six EFDs to find the benefit of moving that particular
part of the database to EFDs.
Figure 7. Performance benefits from moving a partial database
The data in Figure 7 confirms Oracle’s recommendations about Redo Log files. The overall gain was only
1% by moving logs on to EFDs. The logs can safely be left on their own set of Fibre Channel drives while
EFDs can be used for moving other latency sensitive parts of database to maximize the benefit.
Moving of high Object Intensity objects to EFDs may provide significant cost-effective performance
benefit. In this test, an 18% gain was observed when only 2% of the data (top three objects with high
Object Intensity) were moved to EFDs. Whenever the DBA or storage admin is posed with a choice to
moving only certain objects of the database because of space constraints, they should resort to the Object
Intensity approach for maximum benefit.
Moving the top tablespace receiving 70% of I/O provided over 2.13 times improvement. It is important to
note that a total of 30% data was moved to get a 2.13 times improvement, which is less cost-effective
compared to moving high intensity objects consuming just 2% of database size.
Relative transactions per minute
1.00 1.011.18
2.132.50
All on FC Logs on EFD High OI on EFD Top TS on EFD
Just 2% data
moved to EFD
30% data with70% I/O
moved to EFD
Moving logs -minimal improvement
0.00
1.00
2.00
1.50
0.50
OI – Object Intensity
TS – Tablespace
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 18
Database tuning is an iterative process. Tuning just the I/O part of the problem may not always deliver the
expected performance benefits, not because of performance capabilities of EFDs but for various other
bottlenecks. The Oracle Database can have bottlenecks because of various resources like CPU, memory,
network, I/O, and sometimes even because of inefficient SQL and poor application logic. It is very
important to understand the real issue before deploying EFDs. Usually a database transaction is a very
complex operation involving:
Several I/O operations of varied size and type
Several CPU intensive operations processing the data obtained from the storage system
May have inherent serialization
Databases have to commit change vectors to transaction logs before proceeding
Data block read cannot happen until the index block is fetched
A transaction cannot be faster than its slowest sub-operation
Figure 8 explains why the applications sometimes may not see relatively higher performance gains even
after moving the entire database to EFDs. Consider a case where the transaction was taking a total of 35 ms
to finish when the database was deployed on Fibre Channel drives. Assume the transaction comprised of
three I/O operations targeting three different data containers consuming 15 ms, 6 ms and 9 ms, respectively,
along with some CPU intensive operations to process the data. Moving the database to EFDs optimized
only the I/O part of the transaction and nothing has changed as far as the CPU intensive operations go.
Hence, the application could only realize an overall gain of 5x (7 ms instead of 35 ms) even though the I/O
operations were completing in 1/15th
the time (2 ms instead of 30 ms).
Application only got 5x (35 / 7) improvement, even when storage got 15x (30 / 2)
Figure 8. Transaction response time improvements from moving the entire database
Depending on the amount of data moved to EFDs in the case of partial database migration, only some of
the I/O operations targeting EFDs would complete faster but the transactions still have to wait for other
operations on the slower Fibre Channel drives to finish. This may result in smaller improvement in the
overall transaction response time. Figure 9 explains this scenario, where the I/O operation against the data
left on Fibre Channel drives still needs 6 ms to finish irrespective of the huge improvements in EFD-based
I/Os, resulting in smaller gains in overall transaction response time.
1m
s
15m
s
1m
s
1m
s
9m
s
2m
s
6m
s
Total= 35msStorage=30m
s
Before
1m
s
1m
s
1m
s
1m
s
2m
s
0.5m
s
Total = 7msStorage= 2ms
0.5m
s
After
Overall Transaction response time before and after deploying flash drives
(Entire database is moved to f lash)
Time spent processing data
Waiting for I/O on FC drive to finish
Legend
Waiting for I/O on flash drive to finish
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 19
Figure 9. Transaction response time improvements from moving a partial database
Application only got 2.4x overall improvement, even when the I/O on flash drives finished in 1/16th the time ( 24/1.5 = 16). The overall transaction response time is not improving significantly because
of partial data left on Fibre Channel drives.
EFDs and an Information Lifecycle Management (ILM) Strategy Most enterprise application data is temporal in nature. The most recent data gets accessed more often than
the older data. It is very common to move the frequently accessed data to a faster storage and similarly
move the less frequently accessed data to cheaper storage like SATA. This type of data classification is the
beginning of an Information Lifecycle Management (ILM) strategy. Data classification is important in
order to provide applications with the most cost-effective storage tier to support their workload needs. It
can be done by placing each application on the storage tier that fits it best, but it can also be achieved by
using multiple storage tiers within the same application.
A common way for deploying a single database over multiple tiers is by file type. For example archive
logs and backup images can use SATA drives while redo logs and data files can use Fibre Channel HDD.
As EFDs add another high performing tier called “Tier 0,” it is now possible to place latency-critical data
files, indices, or temp files on this tier as discussed earlier.
However, when the database is large, in order to achieve optimum utilization of drive resources, it might be
better to place only the data that is accessed most frequently and/or has the most demanding latency
requirements on EFDs. Many databases can achieve this by using table partitioning.
Using analysis techniques such as those presented in this paper, the customer can determine the most active
tablespaces and files that EFDs are uniquely able to help. Placing the LUNs for these tablespaces on EFDs
may provide significant benefit while not requiring the entire database to be on to EFDs.
Table partitioning also creates subsets of the table, usually by date range, which can be placed in different
data files, each belonging to a specific storage tier. Table partitioning is commonly used in data
warehouses where it enhances index and data scans. However, with an ILM strategy in mind, customers
should consider the advantages of using table partitioning for OLTP applications. While partitioning
allows the distribution of the data over multiple storage tiers, including EFDs, it does not address the data
movement between tiers. Data migration between storage tiers is out of the scope of this paper. Solutions
in this space are available by using EMC virtual LUN technology on Dell/EMC CX4 arrays, the Oracle
online redefinition feature, or by using the host volume management features. Virtual LUN technology
may be used to do a seamless migration of database parts to EFDs with zero interruption to host and
applications running on it. An example of using table partitioning is shown in Figure 10.
Total= 35msStorage=30ms
1m
s
15m
s
1m
s
1m
s
9m
s
2m
s
6m
s
Before
Overall Transaction response time before & after deploying flash drives
(Only parts of database moved to f lash)
Time spent processing data
Waiting for I/O on FC drive to finish
Legend
Waiting for I/O on flash drive to finish
1ms
1ms
1ms
1ms
2ms
6ms
Total = 12.5msStorage= 7.5ms
0.5ms
After
Leveraging Dell/EMC CX4 with Enterprise Flash Drives for Oracle Database Deployments
Applied Technology 20
Figure 10. A partitioned table using tiered storage levels
Conclusion Incorporation of enterprise flash drives into Dell/EMC CX4 arrays provides a new Tier 0 storage layer that
is capable of delivering very high I/O performance at a very low latency, which may dramatically improve
OLTP throughput and maintain very low response times. With comprehensive qualification and testing to
ensure reliability and seamless interoperability, Tier 0 is supported by all the key Dell/EMC software
applications such as data replication and remote protection.
Magnetic disk drive technology no longer defines the performance boundaries for mission-critical storage
environments. The costly approach of spreading workloads over dozens or hundreds of underutilized disk
drives may no longer be necessary.
Dell/EMC now combines the performance and power efficiency of flash drive technology with traditional
disk drive technology in a single array managed with a single set of software tools, to deliver advanced
functionality, ultra-performance, and expanded storage tiering options.