DESCRIPTION
Lenel OnGuard and Bioscrypt V-Smart. CONFIGURATION GUIDE -Veriadmin configuration -OnGuard configuration. Overview. Using a biometric/smartcard reader connected to a reader port in 1320, 1300 and 2220. Biometrics are previously encoded in the card in OnGuard - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/1.jpg)
Lenel OnGuard and Bioscrypt V-SmartCONFIGURATION GUIDE
-Veriadmin configuration
-OnGuard configuration
![Page 2: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/2.jpg)
Overview
Using a biometric/smartcard reader connected to a reader port in 1320, 1300 and 2220.
Biometrics are previously encoded in the card in OnGuard
The reader “reads” the biometrics from the card, compares against the finger placed and send the Wiegand that belong to the card trough the Wiegand port
![Page 3: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/3.jpg)
Connection Diagram
![Page 4: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/4.jpg)
If you are configuring a new unit, the Network Setup screen will automatically be displayed. Click
[OK] to access the Network Configuration Manager. If this screen is not automatically displayed, from
the Configure menu, select Network Setup.
Veriadmin Configuration
![Page 5: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/5.jpg)
Click “ADD UNIT” to get the reader online.
The next step is Advanced Botton, it is displayed the Unit Parameters
Veriadmin Configuration
![Page 6: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/6.jpg)
Unit Parameter Settings
From the Configure menu, select Unit Parameters
The Unit Parameter Settings window appears.
a. The General tab displays the product, firmware, communication, and template information for the
current reader.
On the Communication tab, assign the network ID, select port mode and baud rate. Select Enable
Port. The settings for an enrollment reader are shown in the picture.
Veriadmin Configuration
![Page 7: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/7.jpg)
Veriadmin Configuration
From the Configure menu, select LED Table Settings.
Configure the LED Table Settings for the reader in Idle, Enroll, or Verify modes. Configure the settings
for the V-Smart reader as shown in the following screenshots
![Page 8: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/8.jpg)
From the Configure menu, select LED Table Settings.
Configure the LED Table Settings for the reader in Idle, Enroll, or Verify modes. Configure the settings
for the V-Smart reader as shown in the following screenshots
![Page 9: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/9.jpg)
Veriadmin Configuration
From the Configure menu, select LED Table Settings.
Configure the LED Table Settings for the reader in Idle, Enroll, or Verify modes. Configure the settings
for the V-Smart reader as shown in the following screenshots
![Page 10: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/10.jpg)
On the Biometrics tab,
– Change the Global Security Threshold to Very High
– Make sure that the Biometric Verification is Enabled, and that Finger Required (under
Template Security) is selected.
– Select the number of fingers required and enter the Inter-Finger Timeout in seconds.
– If you wish, you may enable Password Verification (this will only apply to V-Station-G and VStation-
H units).
![Page 11: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/11.jpg)
Veriadmin Configuration
On the Wiegand tab, set the Pass-Thru Format. Enable Input and Selective Output under Wiegand
I/O.
This format is not in the Bioscrypt reader, in order to upload it, click on Upload custom format and find it in “OnGuard Supplemental Materials disk (disk 2/2)” under the following directory:
Disco 2:\OEM Access Control\Bioscrypt Components\Software\ Lenel64.wgf
![Page 12: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/12.jpg)
Veriadmin Configuration
Smart Card Settings
Configure the Smart Card settings via the Smart Card Manager. This is accessed by clicking the smart
card button in the toolbar. For Reader Type, the smart card technology (MIFARE or iCLASS) should be
stated here.
![Page 13: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/13.jpg)
Veriadmin Configuration
Click [Security Settings] to configure the smart card security settings.
Note that all units should be configured to these specifications for the Smartcard Administrator
SiteKey:
– Primary SiteKey: C5RH9kVI7yDzSQu
– Secondary SiteKey: blank
– “Use software HASH” should NOT be selected
After typing in the site key, click [Change SiteKey].
A confirmation message will be displayed. Click [Accept].
You will be asked to enter the current sitekey. If you have a brand new reader, there is no sitekey
assigned yet and you may leave this field blank. Otherwise, enter the current sitekey.
Click [SAVE Settings].
![Page 14: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/14.jpg)
Veriadmin Configuration
For iCLASS readers, cards should already be encoded. If you require encoding, use an iCLASS encoder
for the enrollment workstation. Using Bioscrypt tools will create a 1K card, which is not practical.
![Page 15: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/15.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Access Control Readers
Click (Add reader) , type a reader name, select the typo reader (ej. Dual interface Rdr 2 (wiegand / Prox).
Select Reader Modes and choose online and offline cases.
![Page 16: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/16.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Workstations
Add a new workstation , click Browse and select the workstation form the network
![Page 17: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/17.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Encoders/Scanners
Creat a new encoder , select the workstation that you added , device type select V-Smart (iCLASS)
Credential technology select iCLASS
![Page 18: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/18.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Card Format
Select Add card format , application is V-smart (iCLASS)
Access Control card format select wiegand 64
SiteKey: C5RH9kVI7yDzSQu (same as configured ver reaeder inVeriadmin)
Click card Layout to check the configuration
![Page 19: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/19.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Card Format
Here you have to check if the configuration is correct
![Page 20: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/20.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Card Format
Add this card format following this configuration showed in the picture
![Page 21: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/21.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Badge Type
Creat a new encoder , select the workstation that you added , device type select V-Smart (iCLASS)
Credential technology select iCLASS
![Page 22: Lenel OnGuard and Bioscrypt V-Smart](https://reader033.vdocuments.us/reader033/viewer/2022061416/56813945550346895da0dea7/html5/thumbnails/22.jpg)
OnGuard Configuration
SYSTEM ADMINISTRATION
Cardholder
Create a new user, select the badge type you have added after you typed all the information select capture, add a biometric finger then click ok and select “ENCODE”