led lighting osram.pdf
TRANSCRIPT
-
7/27/2019 LED lighting Osram.pdf
1/4
ST8-SD4 08.02.2011 Page 1 von 4
SubstiTUBE ST8-SD4Datasheet
www.osram.de
Technical operating data
Product Color Colortemp.
[K]
Lum. Flux
[lm]
Voltage [V] /
Frequency [Hz]
Power
[W]
Radiance-
Angle []
ST8-SD4-765 Daylight 6500 K 1550
230 V
50 Hz23,5 W 70 x 90ST8-SD4-840 White 4000 K 1200
ST8-SD4-830 Warm White 3000 K 1200
LED lamp in T8 shape with G13
socket
Length: 1.212 m; Weight: 420 g
18 high-performance OSLON LEDs
Nominal Power: 23.5 W
For operation with CCG
No rewiring necessary; Luminaire
certifications remain valid
Direct Retrofit for CCG luminaires;
replacement of lamp and included
starter Extremely robust with aluminium heat
sink and polycarbonate cover
Full integrated ECG complies to
relevant standards
Complies with safety standard for selfbalasted LED lamps IEC 62560; VDE
certificied
Up to 50.000 h lifetime
Overpower, overheat, short and open
circuit protected
FineWhite / ANSI Binning for highest
homogeneity
Not for operation with ECG, not
dimmable
Technical Features
VDE certified innovative LED-lamp, easy and
safe to use in CCG installations as direct retrofit.
Energy saving potential of up to 50% by
replacing 36W T8 fluorescent tubes.
Applicable in warehouses, supply rooms,
corridors, industry, stairways, garages, indirect
illumination etc; for applications with high
operating hours.
All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only
reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could dif fer from the typical data.
-
7/27/2019 LED lighting Osram.pdf
2/4
ST8-SD4 08.02.2011 Page 2 von 4
Height [m] Diameter [m]
Illumination4000 K / 3000 K
Illumination6500 K
Emax [lx] Emed [lx] Emax [lx] Emed [lx]
1
1,99
1,44 586 236 741 298
2
3,98
2,89 147 59 185 74
3
5,96
4,33 65 26 82 33
47,955,78 37 15 46 19
5
9,94
7,22 23 9 30 12
Minimum / Maximum ratings
Ambient temperature
Ta
Operating temperature
Tc
Storage temperature
Ts
ST8-SD4-xx -30 50C -30... 75C -30 ... 85 C
Drawings
Tc
VDEREG.-Nr. D457
-
7/27/2019 LED lighting Osram.pdf
3/4
ST8-SD4 08.02.2011 Page 3 von 4
The SubstiTUBE must not be damaged or operated in a damaged
condition.
When operating with CCG, the included SubstiTUBE Start has to beinserted as well. If the conventional starter is not replaced the SubstiTUBE
will start blinking. Switch off immediately, the SubstiTUBE can be
damaged!
Do not use SubstiTUBE in luminaires which do not have any starter or
when the starter cannot be replaced.
The SubstiTUBE emits light only with a limited angle, not like a fluorescent
tube with 360output.
Due to the characteristic light distribution of the SubstiTUBE, the current
luminaire light characteristic will likely change. It is not guaranteed that e.g.
standards for lighting at working places will be complied to after
replacement. A photometric check of the installation is recommended.
The effective energy savings depend on the efficiency of the luminaire
setup to be replaced and should be considered individually in each case.
Particularly ballast losses are reduced to ohmic losses and are normally
only about 1 W 1,5 W.
The SubstiTUBE is protected according to IP20. Applications with external
risk of moisture and dust can be served with an adequately protected
luminaire.
SubstiTUBE may also be driven directly on line voltage. We strongly
recommend to refer to the application note for installation information.
Safety and Application notes
-
7/27/2019 LED lighting Osram.pdf
4/4
ST8-SD4 08.02.2011 Page 4 von 4
Make sure that the supply voltage is disconnected.
Carefully remove the fluorescent tube and starter according to the lamp holder type.
Insert SubstiTUBE
and SubstiTUBE
Start properly.
Below an example for typical lamp holder types is described
Turn the conventional lamp 90 degrees and take it out of the socket.
Remove the conventional starter by turning it.
Insert and latch the SubstiTUBE Start into starter socket.
Insert SubstiTUBE into socket and locate into position by turning 90. Check light
distribution angle.
Installation Instructions
Productname Light color EAN* VPE*
ST8-SD4-765 Daylight / 6500 K 4008321966063
10 x 1ST8-SD4-840 White / 4000 K 4008321966056
ST8-SD4-830 Warm White / 3000 K 4008321966049
Sales and Technical Support
OSRAM GmbH
Hellabrunner Strasse 1D - 81536 Mnchen Germanywww.osram.com+49 (0)89 6213-0
Sales and technical support is gi ven by thelocal OSRAM subsidiaries.On our world w ide homepage all OSRAMsubsidiaries are listed with completeaddress and phone numbers.
Further Information
Ordering guide
* EAN: Ordering number per single module
S-Unit: Module per shipping unit
Brochure A new approach to lightwww.osram.com/led-systems-downloads
1EZW001GB
Brochure Better light in every respect.
www.osram.com/led-systems-downloads
400D125GB
Flyer OSRAM SubstiTUBEwww.osram.com/led-systems-downloads
1EBW004GB
Downloads: Application note, eulumdat files www.osram.com/downloads
For further installation options please see the Application Note
http://www.osram.com/led-systems-downloadshttp://www.osram.com/led-systems-downloadshttp://www.osram.com/led-systems-downloadshttp://www.osram.com/downloadshttp://www.osram.com/downloadshttp://www.osram.com/led-systems-downloadshttp://www.osram.com/led-systems-downloadshttp://www.osram.com/led-systems-downloads