Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit www.prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 PRULITE.COM 213.746.0360 Bionic | Recessed Linear & Wall Wash LED 1 Recessed Linear 02-02-2015 BIO-FLSH-LED4LO-ABW 1784 Delivered Lumens 19 Watts 94 lm/w 1.4 Spacing Criteria 84 CRI 28 R9 R___ (Row length) Note: Individual fixtures are not intended for row mounting Open office illumination, wall washing or grazing, Housing: Extruded aluminum accommodates a wide range of ceiling systems and complex installations. Armstrong TechZone compatible. 4 Optics: Batwing (D1X), Soft Glow (D1), Wall Wash (D1) or precise Wall Graze (D1G). Series: See also our Bionic Perimeter for visual continuity. Our P43 System is nearly identical with the same great optics and a budget-friendly steel housing. LED27 2700K LED3 3000K LED35 3500K LED4 4000K FLSH Flush Lens REG Regressed Lens LO Low MO Me- dium SO Stan- dard HO High PROG Pro- gram- mable Light Out- put (Specify desired lm/ft or w/ft) TMW Textured Matte White Standard YGW Gloss White Y__ Premium Color CC Custom Color ABW Acrylic Batwing Lens (D1X Only) SAL Satin Acrylic (D1 Only) AWL Acrylic Wall Wash Lens (D1W Only) AWW Acrylic Wall Grazer Lens (D1G Only) UNV (120-277) SC Single Circuit D1X Symmetric Batwing w/ 1.4 sc (ABW lens only) D1 Direct (SAL lens only) D1W Wall Wash (AWL lens only) D1G Wall Grazer (AWW Only) D1R Asymmetric to Room (AWL Only) X1 T-Bar 15/16 X1M T-Bar 9/16 X2 Dimensional T-bar Armstrong Interlude® X6 Slot Grid X3 Hard Ceiling Flange Trim X7BF Hard Ceiling Trimless Mud-over Backer Flange M Mixed Ceiling ND Non- Dimming DM10 0-10v 10% Dim- ming (Standard) DM01 0-10v 1% Dimming STEP Step Dimming 100-50-Off DML 1% Lutron Dimming DMD 0.1% DALI Dimming DMG 1% DALI Dimming EML Emergency Battery, Low (D1, D1W ~ 850 delivered lumens, D1G ~ 600) EMH Emergency Battery, High (D1, D1W ~1175 delivered lumens, D1G ~ 900) M1 12˝ MR16 module (adj.) 1/50w (max) lamp M2 12˝ MR16 module (adj.) 2/50w (max) lamp M4 Cross MR16 module (adj.) 1/50w (max) lamp C2 90° 2-Way Lit Corner C3 T-Shape 3-Way Connector C4 90° 4-Way Mitered Connector C8 Wall to Ceiling Connector PRUBIN Note: All MR16s by others TRIM COLOR NOM LNGTH OUT- PUT LED COLOR LENS POSITION SERIES SHIELDING VOLT- AGE CIRCU- ITING DISTRIBUTION CEILING SYSTEMS CONTROLS OPTIONS Type: Job: 5 LED WARRANTY YEAR * ABW-D1X ABW-D1X SAL-D1 AWL-D1W SAL-D1 AWL-D1R/W AWW-D1G *BIO-FLSH-LED4LO-ABW, BIO-FLSH-LED4LO-SAL-D1 and BIO-FLSH-LED4LO-AWL-D1W are DLC QPL listed. For other DLC listings, please consult factory. 67/157/16˝ 41/16˝ 41/16˝ BIO-STD Stan- dard LOW MEDIUM STANDARD HIGH lm/ft 425 665 900 1080 w/ft 5 7 10 12 lm/ft 425 665 900 1080 w/ft 5 7 10 12 lm/ft 425 665 900 1080 w/ft 5 7 10 12 Lumen output may vary +/- 5% 4000K used for lm/ft estimates above 3500K –2% llf, 3000K –4%, 2700K –6% See LED Details PDF for more info

Upload: others

Post on 06-Jul-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit www.prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058

PRULITE.COM 213.746.0360

Bionic™ | Recessed Linear & Wall WashLED

1Recessed Linear02-02-2015

BIO-FLSH-LED4LO-ABW1784 Delivered Lumens19 Watts94 lm/w1.4 Spacing Criteria84 CRI28 R9

2´3´4´6´8´R___ (Row length)

Note: Individual fixtures are not intended for row mounting

Open office illumination, wall washing or grazing,

Housing: Extruded aluminum accommodates a wide range of ceiling systems and complex installations. Armstrong™ TechZone compatible. 4 Optics: Batwing (D1X), Soft Glow (D1), Wall Wash (D1) or precise Wall Graze (D1G). Series: See also our Bionic Perimeter for visual continuity. Our P43 System is nearly identical with the same great optics and a budget-friendly steel housing.

LED27 2700K LED3 3000KLED35 3500KLED4 4000K

FLSH Flush LensREG 1˝ Regressed Lens

LO Low MO Me-dium SO Stan-dardHO HighPROG Pro-gram-mable Light Out-put (Specify desired lm/ft or w/ft)

TMW Textured Matte White Standard

YGW Gloss WhiteY__ Premium ColorCC Custom Color

ABW Acrylic Batwing Lens (D1X Only)

SAL Satin Acrylic (D1 Only)

AWL Acrylic Wall Wash Lens (D1W Only)

AWW Acrylic Wall Grazer Lens (D1G Only)

UNV (120-277)

SC Single Circuit

D1X Symmetric Batwing w/ 1.4 sc (ABW lens only)

D1 Direct (SAL lens only)

D1W Wall Wash (AWL lens only)

D1G Wall Grazer (AWW Only)

D1R Asymmetric to Room (AWL Only)

X1 T-Bar 15/16X1M T-Bar 9/16X2 Dimensional T-bar Armstrong Interlude®X6 Slot GridX3 Hard Ceiling Flange TrimX7BF Hard Ceiling Trimless Mud-over Backer FlangeM Mixed Ceiling

ND Non-DimmingDM10 0-10v 10% Dim-ming (Standard)

DM01 0-10v 1% DimmingSTEP Step Dimming 100-50-OffDML 1% Lutron DimmingDMD 0.1% DALI DimmingDMG 1% DALI Dimming

EML Emergency Battery, Low (D1, D1W ~ 850 delivered lumens, D1G ~ 600)

EMH Emergency Battery, High (D1, D1W ~1175 delivered lumens, D1G ~ 900)

M1 12˝ MR16 module (adj.) 1/50w (max) lampM2 12˝ MR16 module (adj.) 2/50w (max) lampM4 Cross MR16 module (adj.) 1/50w (max) lampC2 90° 2-Way Lit CornerC3 T-Shape 3-Way ConnectorC4 90° 4-Way Mitered ConnectorC8 Wall to Ceiling ConnectorPRUBIN Note: All MR16s by others

TRIM COLOR

NOMLNGTH

OUT-PUT

LEDCOLOR

LENSPOSITION

SERIES SHIELDING VOLT-AGE

CIRCU-ITING

DISTRIBUTION CEILINGSYSTEMS

CONTROLS OPTIONS

Type:

Job:

5LED WARRANTY

YEAR5

LED WARRANTY

YEAR

*

41⁄16˝

67⁄16˝

6”

57⁄16˝

41⁄16˝

ABW-D1X

ABW-D1X

SAL-D1

AWL-D1W

SAL-D1 AWL-D1R/W AWW-D1G

*BIO-FLSH-LED4LO-ABW, BIO-FLSH-LED4LO-SAL-D1 and BIO-FLSH-LED4LO-AWL-D1W are DLC QPL listed. For other DLC listings, please consult factory.

67/16˝57/16˝

41/16˝41/16˝

BIO-STD

Stan-dard

LOW MEDIUM STANDARD HIGH

lm/ft 425 665 900 1080w/ft 5 7 10 12

lm/ft 425 665 900 1080w/ft 5 7 10 12

lm/ft 425 665 900 1080w/ft 5 7 10 12

Lumen output may vary +/- 5% 4000K used for lm/ft estimates above 3500K –2% llf, 3000K –4%, 2700K –6%See LED Details PDF for more info

Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit www.prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058

PRULITE.COM 213.746.0360

Bionic™ | Recessed Linear & Wall WashLED

2Recessed Linear02-02-2015

LUMEN MAINTENANCE Designed to last with cool running mid-power LEDs projected to

maintain 90% (L90) of their initial output for 100,000 hours (at HO), and L70 exceeding 150,000 hours.

LED SYSTEM LED modules and drivers are field replaceable.

PROG (optional) Programmable light output. Specify desired lumens or watts per linear foot. Min: 2.5 w/ft, consult factory for requests above 12 w/ft.

BINNING Standard binning (all Prudential LED boards) includes testing at the chip level and board integration to provide consisten color temperature within a 3-step MacAdam ellipse, with +/- 5% lumen output range and +/- .004 Duv.

PRUBIN™ Prudential Ltg’s exclusive ‘job binning’ method that ensures color temperature consistency across all luminaires on a project. Meticulously testing and labeling EVERY LED board to +/- 25 lumens, +/- 50k CCT and +/- .004 Duv — while also separating positive from negative — allows us to match color, hue and intensity throughout a project and provides a consistent color temperature within a 2-step MacAdam ellipse.

LABELS ETL damp labeled and I.B.E.W. manufactured

ELECTRICAL Must specify LED dimming controls. LED fixtures have constant current driver(s) with less than 20% THD when loaded to a minimum of 60%. Drivers sink a maximum of 6mA per driver. DM10 LED drivers are 0-10V dimmable and are compatible with most 0-10V wall slide dimmers and direct 0-10V analog signal dimmers. Max driver size 1.25˝ w x 1˝ h.

CONSTRUCTION

Housing Extruded aluminum>25% PC recycled, 100% recyclable

Lens Acrylic, 100% recyclable

MOUNTING Recessed into drywall or T-bar ceilings

WARRANTY Single-source, 5 year limited warranty covers standard components and construction

Vertical Angle 0 25 45 65 90

0 621 621 621 621 621

5 616 621 630 638 641

15 585 615 657 683 695

25 527 586 643 665 670

35 447 525 577 592 591

45 354 432 476 464 440

55 258 319 344 299 266

65 169 210 213 170 149

75 86 99 96 75 67

85 23 21 19 17 16

90 0 0 0 0 0

Vertical Angle 0 25 45 65 90

0 769 769 769 769 769

5 762 763 763 760 760

15 720 717 709 698 693

25 642 632 612 592 582

35 538 522 494 469 457

45 421 403 373 349 337

55 303 303 263 243 234

65 199 188 171 157 151

75 100 93 84 78 75

85 24 23 21 21 20

90 0 0 0 0 0

Vertical Angle 0 22.5 45 67.5 90

0 923 923 923 923 923

5 1103 1091 1051 987 921

15 1806 1684 1395 1116 895

25 2434 2424 2012 1249 244

35 1799 1887 2127 1401 764

45 1227 1271 1460 1409 650

55 784 804 884 1075 499

65 450 461 488 602 317

75 195 203 203 245 145

85 29 31 34 40 25

90 0 0 0 0 0

BATWING DISTRIBUTION SAL DISTRIBUTION WALL WASH

Low Output:BIO-FLSH-LED4LO-ABW-D1X1784 Delivered Lumens19 Watts94 lm/w84 CRI28 R94000 CCTLight Labs Test #LL041412303R01

Zonal Lumen Summary:0-90 = 100%

Low Output:BIO-FLSH-LED4LO-04-SAL-D11682 Delivered Lumens19 Watts88 lm/w84 CRI28 R94000 CCTLight Labs Test #L041412304R01

Zonal Lumen Summary:0-90 = 100%

Standard Output:BIO-STD-LED3SO-AWL-D1W3184 Delivered Lumens39 Watts82 lm/w82 CRI15 R93000 CCTLight Labs Test #32216

Zonal Lumen Summary:0-90 = 100%621 769 923

(OPTIONAL)

Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit www.prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058

PRULITE.COM 213.746.0360

Bionic™ | Recessed Linear & Wall WashLED

3Recessed Linear02-02-2015

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7⁄16”

5”

4 1⁄16”6”

5”

4 1⁄16”

5 7⁄16”

(m2) (c2)Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer �ange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11⁄8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7⁄16”

5”

4 1⁄16”6”

5”

4 1⁄16”

5 7⁄16”

(m2) (c2)Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer �ange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11⁄8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

Bionic Wall Wash visual continuity with Bionic open office SAL lens

(m2)(m1)

MOUNTING LOCATIONS

CONNECTORS

(c2)

X1 Adjoining detail

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

version Bversion A

version A version B

version A

Bionic Spec Illos 6 Jan 2015

6 7/16”

5”

4 1/16”6”

5”

4 1/16”

5 7/16”

(m2) (c2)

Connectors

90°

(2) MR 16

5” 12”

12”(m1)

12”

(1) MR 16

5” 5”

Mounting Detail (1) Housing Detail for ¼” - 20 Mounting Conversion Chart

9”

15”

21”

27”

33”

39”

45”

2’Y (From centerline)X

3’

4’

5’

6’

7’

8’

X

YY

¼” Wiring K.O.

Mounting Conversion Chart

9” 15” 21” 27” 33” 39” 45”

2’

Y =*

X = 3’ 4’ 5’ 6’ 7’ 8’

* From centerline

Hanging Drywall Detail

Option to hang drywallfrom backer flange X7BF

Install Options Suspension

Hang ¼-20 orwire from adjustablewire from adjustablehanger bracket

4 optional mounting¼-20 rod positions

Housing knock-outs for ¼-20

Extruded aluminumwall rail (included)

.67”.64”

1”

.64”

1”

.44”

1”

.64”

1”11/8”

X1 X1m X2 X6 X3 X7BF

D1W/D1G Reflector

LED array opposite wall side

Wall

WALL WASH REFLECTOR ORIENTATION4˝

37/

AWL Lens

Groove on LED side

D1W90TMW

AWL Lens

Smooth lens face

Groove on LED side

Bionic LED | Lens orientation

Wall Wash Wall Graze

D1W-AWL

57/16

41/16˝

D1G90TMW

AWW Lens

Groove on LED side

Prisms on both sides

D1G-AWW

87/1 67/1

6¾ 6¾

57/1

43/343/3

37/

WALL WASH LENS ORIENTATION