lecture 4a culture equipment
DESCRIPTION
Industrial Microbiology Dr. Butler 2011TRANSCRIPT
![Page 1: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/1.jpg)
Fig. 3.2 Laminar flow cabinet (class II)
![Page 2: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/2.jpg)
Biosafety Levels• Biosafety Level 1 is suitable for work involving well-
characterized agents not known to consistently cause disease in healthy adult humans, and of minimal potential hazard Precautions against the biohazardous materials in question are minimal, most likely involving gloves and some sort of facial protection.
• Biosafety Level 2 moderate potential hazard to personnel and the environment. Includes various bacteria and viruses that cause only mild disease to humans,
![Page 3: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/3.jpg)
Biosafety levels contd.• Biosafety Level 3 is applicable to agents which may cause serious or
potentially lethal disease as a result of exposure by the inhalation route. The laboratory has special engineering and design features.
• Biosafety Level 4 is required for work with dangerous and exotic agents that pose a high individual risk of aerosol-transmitted laboratory infections, agents which cause severe to fatal disease in humans for which vaccines or other treatments are not available. Multiple airlocks are employed and are electronically secured to prevent both doors opening at the same time.
![Page 4: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/4.jpg)
Fig. 3.6
Tissue culture flasks (T-flasks)
![Page 5: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/5.jpg)
Fig. 3.7 Multi-well plates
![Page 6: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/6.jpg)
Fig. 3.10 Spinner bottle with suspended paddle
![Page 7: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/7.jpg)
Fig. 3.11a Roller bottles of various sizes
![Page 8: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/8.jpg)
Bottles in a roller system Fig. 3.11b
![Page 9: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/9.jpg)
Fig. 10.17
A confluent layer of BHK cells covers two microcarriers
![Page 10: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/10.jpg)
Exchange Capacity (meq/ g)
0 1 2 3 4 5
Pro
duct
ivity
(10
6 cel
ls/
litre
/ h)
0
2
4
6
8
10
12
14
16
Cell yield on microcarriers with varying charge
![Page 11: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/11.jpg)
Non-porous microcarriers• Cytodex
• Cells grow adherent to the surface of the bead• Used for adherent cells• Allows for the growth of adherent cells in scaled up
processes
• 3 varieties: 1, 2, and 3• 1 = positively charged throughout the bead • 2 = positively charged on the surface of the bead• 3 = collagen coated to promote attachment
1 & 3 Most commonly used Cytodex species
![Page 12: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/12.jpg)
Porous microcarriers• Cytopore
• Dextran mesh increases surface area• Cells can lodge themselves in the dextran mesh
• Protection from shear forces• Designed for CHO cells• Positive charge throughout the bead
• 2 varieties: 1 and 2• 1 = 1.1 mEq charge• 2 = 1.8 mEq charge
Amersham Biosciences
![Page 13: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/13.jpg)
Fig. 10.18Comparison of a unit system and a multiple system
![Page 14: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/14.jpg)
Cell encapsulationFig. 10.19
![Page 15: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/15.jpg)
Typical culture vessels suitable for cell growthCulture vessel
Number of culture wells/ unit
Max. culture volume (ml)
Vessel size Growth surface (cm2)
Material
Multiple well plate
96 0.37 10.8 x 6.4 mm (D x diam.)
0.32 plastic
" "
24 3.4 17.6 x 15.5 mm "
1.88 plastic
" "
12 6.9 17.6 x 22.1 mm "
3.8 plastic
" "
6 16.8 17.6 x 34.6 mm "
9.4 plastic
Medical flat bottle
10 125 ml 22 glass
" " " 15 250 ml 30 glass
Roux bottle 50 500 ml 200 glass
T-flask, 25 5.0 50 ml 25 plastic
" , 75 15-30 250 ml 75 plastic
" , 150 75 600 ml 150 plastic
" , 175 50-100 750 ml 175 plastic
![Page 16: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/16.jpg)
Culture vessel 100-200 1250 ml 490 plastic
Culture vessel 100-250 2200 ml 850 plastic
Culture vessel 100-500 4900 ml 1750 plastic
Culture vessel 100 250 ml glass
Culture vessel 250 500 ml glass
Typical culture vessels suitable for cell growthcontinued
Culture vessel Number of culture wells/ unit
Max. culture volume (ml)
Vessel size Growth surface (cm2)
Material
![Page 17: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/17.jpg)
Fig. 3.12a Inverted microscope
![Page 18: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/18.jpg)
Fig. 3.12b Standard microscope
![Page 19: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/19.jpg)
Lecture 4 Animal Cell BiotechnologyCell Culture Conditions and Media
Culture Conditions (Incubator)• cells grow best at 37oC and pH 7.4
• grow slower at slightly < 37oC, > 37oC (39-40oC) may destroy cells
• pH of liquid cultures maintained by bicarbonate-CO2
buffer system
CO2 + H2O HCO3- + H+ , pKa = 6.3
• pH further dependent on enriched CO2 atmosphere in the incubator
![Page 20: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/20.jpg)
Double chamber CO2 incubator Fig. 3.3
![Page 21: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/21.jpg)
Butler, M. 2004. Animal cell culture and technology 2nd ed. London and New York:Garland Science/BIOS Scientific Publishers. P 34.
![Page 22: Lecture 4a culture equipment](https://reader035.vdocuments.us/reader035/viewer/2022081413/5492f03aac7959182e8b4748/html5/thumbnails/22.jpg)
“Good” Buffers - Maintaining pH of a cell culture
- HEPES (pKa = 7.4)- MOPS- Tris
- Each has a specific pKa value- HEPES expensive- Allow pH to drift downwards due to lactic acid
accumulation, HEPES will buffer the system and maintain it +/- of 7.4.