lda18-0675 stantec tower feature lighting designs › infraplan › plans_in...architecture, vibrant...
TRANSCRIPT
ICE Distr ictSTANTEC TOWER FEATURE LIGHTING/ MAJOR DIGITAL SIGN June 1, 2018
Project Team:
CLIENT
ARCHITECT
ICEJV
Stantec Architecture Ltd
Digital Sign and Feature Lighting Report
INTRODUCTION CONTENTS
Executive Summary
DP Approved Concept and Diagrams
Tower Signage Elevations
Technical Information
Lighting Themes
Residential Lighting Impact
Application Letters of Support
1.0
2.0
3.0
4.0
5.0
6.0
EXECUTIVE SUMMARYThe proposed Major Digital Sign meets the intent of both the Capital City Downtown Plan and the AED Zone. The Capital City Downtown Plan speaks to creating a vibrant downtown that will be a regional, national and international centre for arts, culture, festivals and entertainment. Lighting and signage play a very important role in place-making, defining an area as special or unique. Similar strategies have been incorporated in New York’s Times Square, Toronto’s Yonge-Dundas Square, London’s Picadilly Circus or many streets in Asia.
The signage and lighting strategies in the aforementioned places have made these areas famous and unique within their respective cities and recognizable on the world stage. One of the common denominators for these internationally-renowned locations is that these are the areas within their respective cities that are the most tourist and entertainment oriented. The quantity and quality of the digital signs is intended to create energy and drama, and add to local and regional place-making. Our proposed signage seeks to enhance and confirm the unique characteristics of ICE District, both locally and on the world stage.
The overall plan for ICE District provides a pedestrian-friendly street environment, innovative signage, iconic architecture, vibrant architectural lighting and exceptional urban design to create a strong sense of place. The proposed Major Digital Sign is a component of this larger project and needs to be reviewed in the larger context. The Major Digital sign helps to create a sense of excitement and arrival to ICE District with wayfinding properties which extend beyond the site. ICE District is a unique entity within the City, region and even the Province and the sign contributes to the identity of this unique area.
The proposed application conforms with the general intent of the urban design guidelines of the AED zone in terms of the architectural style and urban character of the area. The sign blends seamlessly into the design of the building itself; contains sustainable features in terms of LED lights; adds to the signature of the tower top (including variations in colour); and has the ability to work with signage and lighting in the rest of the district to mark special seasons, weather, events, themes, etc. The Major Digital Sign also contributes to the signature of the building and the City’s skyline with its ability to provide visual interest at the tower top and variation in colours.
The Comprehensive Sign Design Plan will be updated to incorporate the proposed Major Digital Sign.
The AED Zone provides opportunities for Theatrically Programmed Environment signage to be incorporated in different areas throughout the site. Including and not limited to publicly accessible open space and the facades and/or roof structures of buildings. The proposed Major Digital Sign is located on the façade of a building, in line with this regulation.
The area is a hybrid between an entertainment district and an urban village with its mix of allowable uses. The technology of the Major Digital Sign can be adjusted accordingly in terms of intensity of lighting, messaging, or turned off at certain hours such that illumination is minimized beyond the boundaries of the site, limiting and/or preventing potential light pollution and intrusion. The sign is also located on the north face of Edmonton Tower which is not directly oriented towards the hotel or residential development.
DP APPROVED CONCEPT & DIAGRAMS 1.0
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 9
LEVEL 67903305
LEVEL 68908805
LEVEL 69912525
16e
7' - 9
1/2"
2380
Glass Exterior . The use of transpareny to reflect the sky from some angles and show structure from others
Secondary Structure . Support the pixeldome lighting and horozontal elements
Primary Structure . Structural supports
Specific to our AED zoning: section 910.12 (4)(g);Major/Minor Digital Signage is a ‘discretionary’ use class in the zoning regulations meaning it must be approved directly at the discretion of the Development Permit Officer.
Theatrically Programmed Environment (TPE System) signage can be incorporated into publicly-accessible open space, the facades and/or roof structures of buildings within the AED Zone as a Sign Use Class, most notably Major and Minor Digital Signs The TPE System may include, but is not limited to, features such as: - Full running video; - Projection systems on architectural surfaces; - LED lighting embedded into structures/buildings (i.e. nightscaping); - Interactive multi-media technologies; and - Environmental effects (i.e. special effects with the use of water and light).
Schedule 59H regulations are applied to Discretionary Signs in the AED Zone
Diagram
Tower E Stantec Tower: L ight ing Concept
DP APPROVED PLAN
2.38
m3.
72m
REINFORCEMENTAS REQUIRED
SNAP ON ALUMINUMCOVER
THERMAL BREAK
PRESSURE PLATE75
6/12/6mm INSULATINGGLASS UNIT
SNAP-ON VERTICAL CAPWITH TOP AND BOTTOMCLOSURE
AIR SEALGASKET
SSG
ACOUSTIC / SMOKEGASKET
EXTERIOR
INTERIORCL
300
2417
8
75
60
5
75
LIGHTING FIXTURE ASSCHEDULED
AutumnSummerSpr ingWinter
The feature lighting presented at our formal review continues to be studied. The concepts of lit end cap mullions flowing up into the wash of the tower crown remains any important and defining element in the project. Full spectrum LED’s have been explored as a method of executing the concept. Both fixtures currently being explored will facilitate a similar aesthetic of full spectrum controllable light. This canvas would be controlled by the ownership group and could potentially signal civil/district events, changing of the season’s and/or tenant signage.
Pixel Dome Fixture/ GVA
Assembly System/ Steel Mesh by Carl Stahl (or similar to attach to building structure)
Dimensions / Pixel Dome Fixture
Tower Crown - East/West LED Fixtures
Tower Crown
Typical Fin Light Detail
Tower Fins
Crown/ Feature Lighting
Tower E Stantec Tower: L ight ing Concept
DP APPROVED PLAN
TOWER DIGITAL SIGNAGE DRAWINGS 2.0
DN
UP
UP
UP
UP
M
N
P
Q
R
S
T
U
9 10 11 12 13 13.1 14 14.1 15 17e 18e 19e 20
VVe
Ue
Te
Se
Re
Qe
Pe
Ne
Me
102
ST.
103 AVE.
103
ST.
PARKADE / LOADING DOCKACCESS RAMP
667100
667650
667100
PLAZA
OUTLINE OF TOWER ABOVE
TOWER OUTLINE ABOVE
PROPERTY LINE
EXTENT OF BLOCK E/F DEVELOPMENTPERMIT SITE SCOPE
(SITE LANDSCAPE/ SURFACETREATMENT/ ELEMENTS IN FUTURE
'PUBLIC REALM' SCOPE)
PROPOSED CURBALIGNMENT
PROPOSED CURBALIGNMENT
9.1
PROPERTY LINE
667300
OUTLINE OF CANOPY ABOVE
OUTLINE OFCANOPY ABOVE
OUTLINE OFCANOPY ABOVE
PEDWAY ABOVE
OVERHEAD DOOR
SIAMESE CONNECTION
16e
16 17 18 19
TOWER A
PEDWAY ABOVE
PROPERTY LINE
PLAN 1321953BLOCK2 LOT1
GENERALRETAILSTORE
GENERALRETAILSTORE
GENERALRETAILSTORE
GENERALRETAILSTORE
GENERALRETAILSTORE
GENERALRETAILSTORE
GENERALRETAILSTORE
GENERALRETAILSTORE
PLAN 1321953BLOCK2 LOT2
1645
715
3199
1338
1050
667700667750
667100
667700
667700
667725
667450
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 12
E/F
D
JW MARRIOTT
HOTEL
G
Extent of Sign(See Elevation)
Extent of Sign(See Elevation)
Extent of Sign(See Elevation)
Extent of Sign (See Elevation)
Site Plan
Tower E Stantec Tower: Digital S ign Extents
Site Plan
Key Plan
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 13
Area of Lighting Fins
Area of Lighting Crown
North ElevationSouth Elevation West Elevation East Elevation
Total Area: 4023m2
Fin Length247m
Total Area: 572m2
Total Area: 468m2
Total Area: 4641m2
Fin Length223m
52m 21m21m
5.5m
52m
11m
221m
123m
11m
Elevations
Tower E Stantec Tower: Digital S ign Extents
19m
9m
243m
EXTENTS IDENTICAL TO CURRENT DP APPROVED PLANS
TECHNICAL INFORMATION 3.0Specific sign manufacturer has not yet been selected. Manufacturer information will be supplied at time of selection, however Owner confirms sign brightness levels will be in conformance with the following:
1. Ambient light monitors shall automatically adjust the brightness level of the Copy Area based on ambient light conditions. Brightness levels shall not exceed 0.3 footcandles above ambient light conditions when measured from the Sign face at its maximum brightness, between sunset and sunrise, at those times determined by the Sunrise/ Sunset calculator from the National Research Council of Canada (Reference: Section 59.2(5)(a) of the Edmonton Zoning Bylaw 12800).
2. Brightness level of the Sign shall not exceed 400 nits when measured from the sign face at its maximum brightness, between sunset and sunrise, at those times determined by the Sunrise/ Sunset calculator from the National Research Council of Canada (Reference: Section 59.2(5)(b) of the Edmonton Zoning Bylaw 12800).
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 15
01 Pixel Dome Fixture / GVA
02 Assembly System/ Steel Mesh by Carl Stahl or similar to attach to building structure
Precedent / National Library of Belrus / Minsk, Belarus
03 Dimensions / Pixel Dome Fixture
www.gvalighting.com
PixelDOME™ is an RGB Color Changing or Monochromatic pixel luminaire. It is designed to be used in an array for low resolution image creation or color changing effect lighting. Typical applications include‘Architainment’, media façades, low resolution video displays and special effect lighting.
Each PixelDOME™ is a compact aluminum body and an opal acrylic dome. The dome lens provides viewers with a highly saturated body of light with an overall viewing angle of more than 180° PixelDOME™ is IP66 rated for indoor and outdoor locations. Its design is optimized for thermal management and can operate at temperatures from -30°C to +50°C. Bracket Mount, Flange Mount and Junction Box Mounting options are available.
PixelDOME RGB models are controlled via DMX. Monochromatic versions can be supplied with DMX dimming input or with no control (no dimming, on/off).
Pixel Dome LED Fixture
Tower Top Panel SystemDP APPROVED
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 16
I. LIGHT PARTS II. ASSEMBLED III. POWER AND CONTROLLER
WIDE RANGE OF COLOURS
2-FOOT MODULE - DIMENSION (WXH) 1 1/2” X 1 5/8”
Images
Tower FinsDP APPROVED
LIGHTING THEMES 4.0Proposed Signage Content Themes: #1 - Approved lighting (colour/ Aurora Borealis) #2 - Community themes / public art #3 - Corporate Advertising (Major Digital Sign)
Our proposal includes for ‘corporate advertising’ to be a permitting ‘signage theme’ in order to offer the ability to display themes #1 and #2. Expanded details including hours of operation, duration/speed of transitions, and full technical operating requirements will be made available once the concept in principle can be reviewed and approved.
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 18
Tower E Stantec Tower: L ight ing Themes
Feature L ight ing Theme: “Canada Day” Example
Feature L ight ing Theme: “Oi lers” Example
Feature L ight ing Theme: “Pr ide” Example
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 19
Tower E Stantec Tower: L ight ing Themes
Feature L ight ing Theme: “Oi lers” Example
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 20
Feature L ight ing Branding: “Rogers” Example
Feature L ight ing Branding: “Ford” Example
Feature L ight ing Branding: “TD Bank” Example
Tower E Stantec Tower: L ight ing Branding Themes/ Major Digital S ign
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 21
Feature L ight ing Branding: “Rogers” Example
Tower E Stantec Tower: L ight ing Branding Themes/ Major Digital S ign
RESIDENTIAL L IGHTING IMPACT 5.0
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 23
Tower E Stantec Tower: Residential L ight ing Impact
LED Mull ions (@ 10’ intervals) L5 to Tower Top
LED Mull ions (@ 10’ intervals) L2 to Tower Top
LED
Pix
el
Do
me
s st
art
ing
@ L
67 -
(77
0’ a
bo
ve g
rad
e)
LED
Pix
el
Do
me
s st
art
ing
@ L
67 -
(77
0’ a
bo
ve g
rad
e)
North Section
Residential
Hotels
Area of Imact of Lighting
Towers
Radial Distances from Center
Tower Heights#
50m
150m
200m
OILERS WAY
103 AVE
OILERS WAY
103 AVE
02 30
69
5527
31
25
33
33
4
4
4 42
32
14
10
5
1927
24
36
27
25
2320
30
28
35
24
20
10
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 24
West Section
Tower E Stantec Tower: Residential L ight ing Impact
LED Mull ions (@ 10’ intervals) L5 to Tower Top
LED Mull ions (@ 10’ intervals) L2 to Tower Top
LED
Pix
el
Do
me
s st
art
ing
@ L
67 -
(77
0’ a
bo
ve g
rad
e)
LED
Pix
el
Do
me
s st
art
ing
@ L
67 -
(77
0’ a
bo
ve g
rad
e)
Residential
Hotels
Area of Imact of Lighting
Towers
Radial Distances from Center
Tower Heights#
50m
150m
200m
OILERS WAY
103 AVE
OILERS WAY
103 AVE
02 30
69
5527
31
25
33
33
4
4
4 42
32
14
10
5
1927
24
36
27
25
2320
30
28
35
24
20
10
APPLICATION LETTERS OF SUPPORT 6.0
1. Downtown Business Association2. NAV Canada
The following groups were sent copies of the proposal as summarized in this package and have provided letters of support and/or acknowledgement of review;
EDMONTON ICE DISTRICT | TOWER E Major Digital Sign and Feature Lighting Report June 1, 2018 26
From: Ian O’Donnell [mailto:[email protected]] Sent: Monday, December 04, 2017 9:01 AMTo: Lew, Yolanda <[email protected]>Subject: Ice District
Good morning Ms. Lew,
Thank you for providing the Ice District Feature Lighting package for our review. We have reviewed it in its entirety and have no issues with what is being presented. It aligns with our Winter City Strategy to bring additional appropriate lighting to our buildings and entertainment/civic areas, to help illuminate darker months.
The AED zone is a unique area within our Downtown/City; this will help enhance its signature architecture and bring a new sense of vibrancy to the area.
Sincerely,
Ian O’DonnellExecutive Director10121 Jasper AvenueEdmonton, AlbertaT5J 4X6(780) 426-8575 To Support, Connect, & Enrich Edmonton’s Downtown Community
1601 Tom Roberts Avenue, Ottawa, ON, K1V 1E5 1601 avenue Tom Roberts, Ottawa, Ontario, K1V 1E5 Telephone: +1 (866) 577-0247, Fax: +1 (613) 248-4094 Téléphone: +1 (866) 577-0247, Télécopieur: +1 (613) 248-4094 Z-LDU-101 Version 17.5 7 July 2017
November 12, 2017
Your file LDA17-0481 (10111-104 Avenue NW)
Our file 17-3769
Mr. Sean Lee City of Edmonton 6th Floor Edmonton Tower, 10111-104 Avenue NW Edmonton AB T5J 0J4 RE: Development Proposal/Plans: Re-Zoning - Edmonton, AB (N53° 32’ 44.8” W113° 29’ 41.3” / 436.6798’ AGL / 2625.6562’ AMSL) Mr. Lee, NAV CANADA has evaluated the captioned proposal and has no objection to the project as submitted. NAV CANADA does not require notification of construction; however, if you should decide not to proceed with this project, please advise us accordingly so that we may formally close the file. If you have any questions, contact the Land Use Department by telephone at 1-866-577-0247 or e-mail at [email protected]. NAV CANADA's land use evaluation is valid for a period of 12 months. Our assessment is limited to the impact of the proposed physical structure on the air navigation system and installations; it neither constitutes nor replaces any approvals or permits required by Transport Canada, Industry Canada, other Federal Government departments, Provincial or Municipal land use authorities or any other agency from which approval is required. Industry Canada addresses any spectrum management issues that may arise from your proposal and consults with NAV CANADA Engineering as deemed necessary. Yours truly,
Gheorghe Adamache | NAV CANADAManager - AIM IFP Service Delivery cc NOPR - Northern and Prairie Region, Transport Canada CFH7 - (ROYAL ALEXANDRA HOSPITAL)(HELI) CEW7 - UNIV OF ALBERTA (STOLLERY CHILDREN’S HOSP MAHI)(HELI) CMC2 - MISERICORDIA (COMMUNITY HOSPITAL)(HELI)
Tower E Stantec Tower: Letters of Support