D25 Lay-in lug connectors DB Cat. no. Dimensions Conductor range Stud size H W L AWG mm 2 in. mm in. mm in. mm in. mm CULL414 4-14 16-1.5 0.22 5.59 0.78 19.81 0.38 9.65 1.07 27.18 CULL414TP* 4-14 16-1.5 0.22 5.59 0.78 19.81 0.38 9.65 1.07 27.18 * Tin-plated. 90 °C rating. Cat. no. Conductor range Stud size AWG mm 2 in. mm LL414 #4–#14 16–1.5 0.22 5.59 LL1014 1/0–#14 50–1.5 0.27 6.86 LL306 3/0–#6 70–16 0.33 8.38 LL2506 250–#6 120–16 0.33 8.38 These grounding connectors are dual rated for aluminum and copper conductors. The open-face design allows the installer to quickly lay in the grounding conductor as a jumper. W H Copper lay-in lug connectors • Ideal for swimming pool grounding applications • Carries “DB” marking for direct burial • Open-faced design enables installer to quickly lay in the grounding conductor as a jumper to multiple conduits with no break in the ground conductor Diagram Blackburn lay-in lug EZGROUND CONDUIT HUBS AND LAY-IN LUG CONNECTORS

Upload: others

Post on 05-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lay-in lug connectors - Installation Products · 2019-12-12 · Lay-in lug connectors Cat. no. Range (AWG or kcmil) Torque MLG25020 250 through 2/0 stranded 40 feet/pounds — Mechanical

D25

—Lay-in lug connectors

DB

Cat. no.

Dimensions

Conductor range Stud size H W L

AWG mm2 in. mm in. mm in. mm in. mm

CULL414 4-14 16-1.5 0.22 5.59 0.78 19.81 0.38 9.65 1.07 27.18

CULL414TP* 4-14 16-1.5 0.22 5.59 0.78 19.81 0.38 9.65 1.07 27.18

* Tin-plated.90 °C rating.

Cat. no.

Conductor range Stud size

AWG mm2 in. mm

LL414 #4–#14 16–1.5 0.22 5.59

LL1014 1/0–#14 50–1.5 0.27 6.86

LL306 3/0–#6 70–16 0.33 8.38

LL2506 250–#6 120–16 0.33 8.38

These grounding connectors are dual rated for aluminum and copper conductors.The open-face design allows the installer to quickly lay in the grounding conductor as a jumper.

W

H

Copper lay-in lug connectors• Ideal for swimming pool grounding applications• Carries “DB” marking for direct burial• Open-faced design enables installer to quickly lay

in the grounding conductor as a jumper to multiple conduits with no break in the ground conductor

Diagram

—Blackburn lay-in lug

E ZG RO U N D CO N D U IT H U B S A N D L AY- I N LU G CO N N EC TO R S

Page 2: Lay-in lug connectors - Installation Products · 2019-12-12 · Lay-in lug connectors Cat. no. Range (AWG or kcmil) Torque MLG25020 250 through 2/0 stranded 40 feet/pounds — Mechanical

D26 E ZG RO U N D/FU R S E W E LD/B L ACK B U R N G R O U N D IN G S Y S TEMS

—Lay-in lug connectors

Cat. no. Range (AWG or kcmil) Torque

MLG25020 250 through 2/0 stranded 40 feet/pounds

—Mechanical lay–in ground connector

Step 1• Open grounding connector by loosening bolts• Swing top and center clamps to the side to

expose lower conductor grooves.

Step 2• Lay in first conductor into lower conductor

groove

Step 3• Rotate center clamp into position over first

conductor

Step 4• Lay in second conductor into center clamp

conductor groove (parallel conductor style is shown)

Step 5• When conductors are in place, rotate top clamp

over the second conductor and torque bolts to 40–45 ft-lb (cross conductor style is shown)

Loosenbolts

Top clamp

Swing open

Center clampSwing open

Lower conductor groovesLower conductor

grooves

First conductor

Lower conductor grooves

First conductor

Rotate

First conductor

Second conductor

RotateTop clamp

Torque Bolts to 40–45 ft–lb