Launching MIURA sample prep system
DSP SYSTEMS Information : [email protected] or +31-344-846303 Internet: www.dspsystems.eu
The next generation of automation
The Full-Automatic Sample Preparation System for dioxins and PCBs analysis has three features…
High Performance Clean-up User-friendly Column Design Unique way of flow switching
Main advantages
Low solvent consumption Hexane 90 ml Toluene 4 ml
Run-time 90 minutes No cross contamination Columns easy to connect and no leakage Competitive prices
Introduction
Availability and Service
• The system is in Europe and several other countries available via DSP Systems as :– GO-2HT capable of running two samples parallel– GO-4HT capable of running four samples parallel– GO-6HT capable of running six samples parallel
• Installation, service and maintenance will be supplied by DSP Systems
• A full maintenance contract is optional with a response time of 24 hours for customers within a radius of 300 km from the middle of the Netherlands and 48 hours within the rest of the EU countries
General Dioxin method
Sample
Sample extraction or dilution
Clean-up
GC-HRMS or GC-MS/MS
concentration
concentration
spike with 13C labelled standards←
←add Recovery standards
add Control standard←
Required time 1-2 days
Background --- Features of New System
High performance clean-up
User-friendly column design
Unique way of flow switching without valves
High performance clean-up 4 columns
Silver nitrate Si column Sulfuric acid Si column Carbon column Alumina column
Heated Purification and elution• Enhances dioxins elution speed• Accelerate a chemical reaction
User-friendly column design … Unique way of flow switching without
valves
Background --- Features of New System
Clap!
Clap!
Clap!
High performance clean-up User-friendly column design
• Easy applying sample
• Easy connection
• Disposable parts
• No cross contamination
• No washing is required
Background --- Features of New System
High performance clean-up
① 90 mL of hexane for eluting dioxins and PCBs: i. Trapping dioxins and NO-PCBs on carbon ii. Trapping MO and NDL-PCBs on alumina
② Open the pinch valve
③ Elution PCBs with 1.5 ml of toluene
④ Close the pinch valve and open the other pinch valve
⑤ Elution Dioxins with 1 ml of toluene
Background --- Features of New System
First resultsRecovery in real samples
Congener Avg Recovery (% ) Stdevn=17
2378- 13C12- TCDF 83,4 10,112378- 13C12- PeCDF 90,4 15,023478- 13C12- PeCDF 95,5 19,3123478- 13C12- HxCDF 81,3 11,4123678- 13C12- HxCDF 84,4 12,9123789- 13C12- HxCDF 79,7 13,3234678- 13C12- HxCDF 83,5 11,21234678- 13C12- HpCDF 81,6 11,51234789- 13C12- HpCDF 85,8 13,8OCDF- 13C12 77,5 14,3
2378- 13C12- TCDD 93,3 12,512378- 13C12- PeCDD 96,3 18,3123478- 13C12- HxCDD 90,9 13,2123678- 13C12- HxCDD 77,6 10,2123789- 13C12- HxCDD 89,3 13,51234678- 13C12- HpCDD 84,6 13,7OCDD- 13C12 87,6 20,2
PCB 77- 13C12 79,2 12,6PCB 81- 13C12 79,4 14,2PCB 126- 13C12 90,5 14,2PCB 169- 13C12 90,1 15,6
PCB 105- 13C12 92,9 14,0PCB 114 13C12 89,8 11,0PCB 118- 13C12 87,5 10,7PCB 123- 13C12 85,5 8,7PCB 156- 13C12 84,4 11,4PCB 157- 13C12 84,6 13,1PCB 167- 13C12 79,6 15,9PCB 189- 13C12 82,7 14,4
PCB 28- 13C12 77,3 15,9PCB 52- 13C12 80,2 11,6PCB 101- 13C12 80,7 11,2PCB 153- 13C12 79,6 12,9PCB 138- 13C12 73,4 13,2PCB 180- 13C12 76,9 14,0
Sample type:
PFADFish oilMix of fatty acidMineralsCompound feed
First results PeCDD trace peak of interest is 1,2,3,7,8 *1 sample tocopherol
Result after classical clean-up
Result after clean-up using the new system
*1 TEF = 1,0
First results HxCDF trace peak of interest is 1,2,3,5,7,8; sample tocopherol
Result after classical clean-up
Result after clean-up using the new system
Conclusion
1.5hrs1 hr
Extraction Purification Measurement
1.5hrs GC-MSMS
GC-HRMS
• Multiple sample extraction• Full Automatic Sample preparation System• GC-MSMS or/and GC-HRMS• High sample Throughput• Eco-friendly analysis• Results available within 8 hours
60mL 100mL
More information
• Phone : +31-344-846303
DSP SYSTEMS Information : [email protected] or +31 6-1366 4946