For main pipes DN450 and above, with a minimum wall thickness of 50mm. Fits any DN150 lateral pipe in conjunction with a Flexseal Multibush Lower cost in comparison to junctions Accepts a deflection on the lateral pipe of 15° Withstands an internal pressure of 1 bar No adhesives, sealant or concrete required Lightweight, easy to handle for quick installation No need to excavate around the pipe and disrupt the pipe bedding WRc Approved™ Flexseal’s Unisaddle FA150U is also available for similar applications. Lateral Connections The Flexseal FA150B is used to connect a DN150 lateral pipe into a large diameter thick walled sewer or surface water pipe. www.flexseal.co.uk Flexseal, Endeavour Works, Valley Park, Newlands Way, Wombwell, Barnsley S73 0UW Tel: +44 (0) 1226 340 888 | Fax: +44 (0) 1226 340 999 | Email: sales@flexseal.co.uk Unisaddle FA150B Global leaders in flexible couplings, drainage & plumbing systems A p p r o e d TM Twistable collar accommodates specific pipe wall thicknesses, making this product universal to many different main pipes.

Upload: others

Post on 30-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Lateral Connections - Flexseal

For main pipes DN450 and above, with a minimum wall thickness of 50mm.

• FitsanyDN150lateralpipeinconjunctionwithaFlexsealMultibush• Lowercostincomparisontojunctions• Acceptsadeflectiononthelateralpipeof15°• Withstandsaninternalpressureof1bar• Noadhesives,sealantorconcreterequired• Lightweight,easytohandleforquickinstallation• Noneedtoexcavatearoundthepipeanddisruptthepipebedding• WRcApproved™

Flexseal’s Unisaddle FA150U is also available for similar applications.

Lateral Connections

The Flexseal FA150B is used to connect a DN150 lateral pipe into a large diameter thick walled sewer or surface water pipe.

www.flexseal.co.ukFlexseal,EndeavourWorks,ValleyPark,NewlandsWay,Wombwell,BarnsleyS730UWTel:+44(0)1226340888|Fax:+44(0)1226340999|Email:[email protected]

Unisaddle FA150B

Globalleadersinflexiblecouplings,drainage&plumbingsystems

A p p r o e d

TM

Twistable collar accommodates specific pipe wall thicknesses, making this product universal to many different main pipes.

Page 2: Lateral Connections - Flexseal

Lateral Connections

www.flexseal.co.ukFlexseal,EndeavourWorks,ValleyPark,NewlandsWay,Wombwell,BarnsleyS730UWTel:+44(0)1226340888|Fax:+44(0)1226340999|Email:[email protected]

Material

Saddle body EPDMelastomerconformingtoBSEN681-1:1996Saddle sleeve IndustrialgradeABSplasticClamp band Austeniticstainlesssteelgrade1.4301(304)Min wall thickness required 50mmLateral pipe deflection 15°Maximum internal pressure 1bar/14.50psiMaximum vertical Load 2TonneLateral pipe shear loading 25bar/362psiMax jetting pressure 3,000PSICored hole size 172mm

Drill requirementsHiltiDD160-DD2--orequivalentWetCoringDrill11/4”UNCfemalebossforconnectiontothedrillingrig.13toothsegments.SomedrillswillrequireanAdaptortoconnectthecorebit.

Approvals WRCApprovedDocumentPT/243/0405fortheconnectionoflateralsontomainconcretegravitysewersintherangeDN450-DN1500

Conforms to

Sewers for Adoption 7th Edition “SaddleConnectionscanbeused,butonlywhentheinternaldiameterofthehostpipeisatleast150mmgreaterthantheinternaldiameterofthebranchpipe”(fora150mmlateralpipemainsewermustbe300mmandabove)

A Guide to Sewerage Operational Practices“Theholeinthemainsewershouldonlybemadeusingacirculardiamondcorecutter...”

BSEN 1610:1998 Construction and Testing of Drains and Sewers “Thesaddlefittingshouldbepositionedontheupperhalfofthepipe,preferablywithitsaxisat45°totheverticalplanethroughtheaxisofthepipe.”

Page 3: Lateral Connections - Flexseal

www.flexseal.co.ukFlexseal,EndeavourWorks,ValleyPark,NewlandsWay,Wombwell,BarnsleyS730UWTel:+44(0)1226340888|Fax:+44(0)1226340999|Email:[email protected]

V010APR18

Lateral Connections

FA150B SaddleConnectingpipesofdifferentoutsidediametersTheFlexsealMultibush(MB150),whichismanufacturedtotherequirementsofBSEN295-4:1995,isrecommended.

Pipe OD Multibush (MB150) Pipe Material Illustration

160-166mm 12mmFolded DN150Quantum,CastIron(SMU,SML,Ensign),160mmPVC

170-177mm 8mmLargeEnd DN150DuctileIron,Ultra-Rib.CastIron(Drain)

178mm 4mmSmallEnd Supersleve,TwinwallPlastic

180-190mm NoBush SaltGlazedClay

Fitting Instructions6easysteps

31 2

5 64

1.Diamondcorea172mmholeattheselectedpositionintotheconcretepipe.Ensurethepipewallandsurroundingareaiscleanandfreefromslurry/debrisandmeasurethewallthickness.

2.Removetheinternallockingsleevefromthesaddlebody.Adjustthethreadedcollarontheoutersleevesothatitmeasures10mmlessthanthethicknessofthepipe.

3.Positionthesaddleintheholeensuringitsits10mmawayfromtheinternalwallofthepipe.Thisisachievedbyplacingyourhandinsideandfeelingtheinsideofthepipewall.

4.Breakoffthetabsfromthelockingsleeveandlubricateusingwater.Placethelockingsleeveintothesaddlebodyandlineupthearrows.Pushthesleeveintotheboreofthesaddle.

5.Drivethelockingsleeveevenlyaroundthecircumferenceuntilfullylocked.Itisrecommendedthatawoodenblockisusedwhenusingahammertolockthesaddleintoposition.

6.Insertthepipeintothefittedsaddleandtightentheclampbandtotherecommendedtorque.UseaMultibush(MB150)ifrequired.

Note: A diamond cored hole of 172mm (+1 / -0mm) should be cored using the correct equipment.