VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES

ii 31 Dec 2012

Foreword by Peter Holland CBE OStJ QFSM, Chief Fire Officer of Lancashire Fire and Rescue Service

Dear Specifier

When we look back at 2011 we will all remember (sadly) the terrible images of fire and vandalism caused by rioting and protest across the world.

There is no doubt therefore that designers and owners must consider not just life safety but also the additional business risk to property and infrastructure by ‘unexpected’ threats such as arson or physical attack over and above the regulatory needs to protect life and property against the threat of fire and crime. It is impossible to foresee all eventualities of course, but by specifying effective, properly installed fire and security protection systems, the negative consequences of an incident can be reduced considerably.

The most effective way of doing this is to select products, systems and installers that are approved and listed by an independent third party certification body such as LPCB. Third party approval is confirmation that these products, systems and their installers have met and continue to meet appropriate standards.

As an independent certification body, LPCB has one of the most extensive fire and security testing laboratories in the world and its approvals are undertaken by a highly qualified team of expert scientists and engineers. LPCB develops standards within a framework that includes rigorous consultation and involvement of a wide range of stakeholders that includes clients, insurers, manufacturers, public bodies and emergency services. This all goes to make the LPCB certification mark “A Mark you can trust”

I have, therefore, no hesitation in recommending the products and services, listed in Red Book 2012, to you.

IntroductionWelcome to the 2012 Edition of the “Red Book”, the LPCB List of Approved Fire & Security Products and Services. The Loss Prevention Certification Board (LPCB) is part of BRE Global and together with the listings, the LPCB mark signifies that products and services have been approved by LPCB. The Red Book is an essential reference for specifiers, regulators, designers and end users of these products and services - if it is listed here, you know it has been checked out by people you can trust.

Page 3: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES

31 Dec 2012 iii

BRE Global is part of the BRE Group under the BRE Trust. It is an independent third party approvals body offering certification of fire, security and sustainability products and services to an international market.

BRE Global - protecting people, property and the planet.

The Red Book is divided into sections which list related groups of products and services such as suppression, security and so on. Each section also summarises the technical basis for the approval of each product or service. The Red Book should always be used in conjunction with rules, regulations and design specifications required by the relevant Authority.

The 2012 edition of the Red Book comprises 2 Volumes:

Volume 1: Fire Detection and Alarm products & servicesFire Suppression products & servicesRelated Installers

Volume 2: Passive fire protection products & servicesSecurity Protection systemsRelated InstallersManagement SystemsConstruction products

Listings are given in the name of the manufacturer or service provider, in alphabetical order. The Red Book is available free of charge in hard copy, CD and memory stick. It is also available on our website at www.redbooklive.com <<<http://www.redbooklive.com>>> The website gives you the most up to date information on which products are approved and in the unlikely event of suppliers needing to recall products or services or suspend production will identify these.

Red Book updatesProduct and services approval details are amended regularly. To ensure that you are using the most up to date information please refer to www.redbooklive.com <<<http://www.redbooklive.com>>>

What is Third Party Approval?Third party approval (or certification) is a conformity assessment process, carried out by a body that is independent of both supplier and customer organisations. It provides confirmation that products and services have met and will continue to meet the requirements of specified standards and other normative documents.

Third party approval provides a safeguard as to the performance of a product or service. LPCB third party product approval schemes are quality assurance schemes and comprise initial type testing and technical evaluation, assessment and surveillance of the manufacturer’s quality system and production procedures, regular audit testing, labelling and listing.

Similarly, LPCB schemes for suppliers of services (installers) are also quality assurance schemes comprising a technical assessment of a contractor’s capability, assessment and surveillance of the installer’s quality system and production procedures, regular inspection of completed installations and listing.

Benefits of Third Party ApprovalA frequent concern of stakeholders is in knowing whether a product will perform in accordance with the stated specifications. These concerns can involve such product attributes as safety, health or environmental impacts, durability, compatibility, suitability for intended purposes or for stated conditions, and other similar considerations. These issues can all be addressed through product approvals.

For specifiers, regulators, insurers, manufacturers and installers, the benefits of an LPCB approval are:

For specifiers and regulators: Risk reduction - specifying LPCB approved products and services demonstrates due-diligence and

best endeavour and mitigates against possible accusations of negligence.

Page 4: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES

iv 31 Dec 2012

Avoidance of costly mistakes - you can trust LPCB approved products and services to conform each and every time.

Time - using Red Book Live to search for and assess products and services can save you time.

For manufacturers and installers: Increased global sales - LPCB approval is recognised and specified widely throughout the world. In

some territories LPCB approval is a mandatory requirement. Added value of the product or service - LPCB approved products and services are recognised as

providing added value given their ability to conform each and every time. Reduced liability - LPCB approved products and services demonstrate due-diligence which can

reduce liability for both you and your customers.

The LPCB Mark is a Mark you can trust.

The Third Party Approval ProcessLPCB offers approvals to existing British, European, International and LPCB’s own Loss PreventionStandards (LPSs). LPCB’s LPS approval schemes for both products and services are essentially level 5 schemes, as described in ISO/IEC Guide 67, with the added requirement to have a quality system certificated to ISO 9001.

The technical requirements of LPCB schemes are given in Loss Prevention Standards (LPSs). Thesedocuments are drafted by LPCB technical experts in conjunction with appropriate external experts.

They are then peer reviewed by representatives from trade bodies, regulators, insurers, specifiers,manufacturers and other suppliers.

Finally these documents are approved for use by the BRE Global Governing Body; the Body that oversees all of the certification activities of BRE Global including LPCB.

On occasion, approval may be carried out to other international standards where this is appropriate to a particular territory.

Product schemes comprise: Initial type testing and evaluation of product, sampled by LPCB Approval and surveillance of the manufacturer’s (or supplier’s) quality management system to ISO

9001 (if you have products in for testing at LPCB, it generally costs little or no more to achieve ISO 9001 certification).

Assessment and surveillance of the manufacturer’s (or supplier’s) factory production control system (FPC)

Periodic audit testing of the product from either the factory or marketplace Labelling or marking as appropriate. Listing of the approved product (service) in the Red Book.

Installer schemes comprise: Technical assessment of the installation contractor’s capability Approval and surveillance of the contractor’s quality management system to ISO 9001 or assessment

against the requirements of the relevant Loss Prevention Standard where ISO 9001 is not appropriate. (If you have applied for LPCB assessment of your services, it generally costs little or no more to achieve ISO 9001 certification).

Regular surveillance inspections of on-going installations The issue of Certificates of Conformity to demonstrate compliance for each installation Listing of the approved installer in the Red Book.

The LPCB MarkAfter approval of a product or service the manufacturer or service provider is allowed to place the LPCB certification mark, as shown below*, on the product, packaging and literature etc. In September 2011 this image was updated from

Page 5: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES

31 Dec 2012 v

this to

A transition period of up to three years is being allowed for the change, so although we expect many of our clients’ product(s) will already be carrying the new version of the mark, the ‘old’ mark remains valid and you can still rely on the products carrying the old mark where their certificate was issued before 1 October 2011. Below the mark you should always find the product/service certificate number so you can always check if a listing still valid by going to www.redbooklive.com.

Where LPCB holds accreditation through the United Kingdom Accreditation Service (UKAS), the approved company is allowed to include the UKAS logo alongside the LPCB mark for certain applications e.g. promotional literature or material and stationery, as shown below.

On products where either for reasons of space or cost using the above full mark is not practical then the following simplified mark may be used directly on the product or a permanently affixed label.

The LPCB scheme rules define how and where the marks can be used.

The LPCB horseshoe is the mark you can trust and it is recognised in 45 countries around the world by regulators, specifiers, designers and end users.

Full details of LPCB accreditation can be found on the UKAS website at www.ukas.com<<<http://www.ukas.com>>>

European DirectivesFor products to be placed on the European market, manufacturers must comply with the regulatoryrequirements of a number of European Directives.

To demonstrate compliance with these Directives, a manufacturer must make a declaration, based on an evaluation of the product, and affix the relevant mark.

For some products the manufacturer will need to use the services of a Notified Certification Body or Notified Test Laboratory to demonstrate that the evaluation of the product has been carried out in whole or in part by a

Page 6: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

VOLUME 1 LIST OF APPROVED PRODUCTS AND SERVICES

vi 31 Dec 2012

body independent of the manufacturer. Other products can merely be marked on the basis of a self declaration of conformity by the manufacturer.

The relevant mark shows that a product meets minimum regulatory standards of health and safety as laid down in the Directives. It is not a quality mark and does not necessarily relate to the functional performance of the product.

BRE Global is a Notified Body for:

The Construction Products Directive (CPD)

Pressure Equipment Directive (PED)

Marine Equipment Directive (MED)

Transportable Pressure Equipment Directive (TPED)

Where the services of a Notified Body is required in order for a manufacturer to affix a mark to a product, BRE Global can provide a comprehensive service.

Other Approvals listed in the Red BookBRE Global carries out approvals of a number of other construction products and management systems under other approval brand names.

The details of these schemes are given in the relevant introductory sections.

For Fire and Security Products and Services Trust the LPCB Mark

Other Listings from BRE Global

Page 7: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

CONTENTS

31 Dec 2012 vii

1 Fire detection and alarm products, systems & cables 1SECTION 1 LPS 1014 certified fire detection and alarm system firms 3SECTION 2 Fire detection and alarm systems 14SECTION 3 Control and indicating equipment 17SECTION 4.1 Commercial detectors 156SECTION 4.2 Domestic alarms - smoke, heat and carbon monoxide 302SECTION 5 Manual call points 309SECTION 6 Line units 338SECTION 7 Alarm warning devices 358SECTION 8 Fire resistant cables 425SECTION 9 Alarm receiving centres 496SECTION 10 Alarm transmission and fault monitoring equipment and signalling systems

498SECTION 10.1 Alarm transmission and fault warning routing equipment 500SECTION 10.2 Supervised premises transceivers (fire) - LPS 1277 Issue 2.2 501SECTION 10.3 Supervised premises transceivers (fire) - LPS 1277 Issue 3 502

Page 8: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

INDEX

viii 31 Dec 2012

22M KABLO SAN. ve TIC. A.S. 427AAC Electrical Wholesalers Ltd 428ADI International 157ADT Fire and Security 3, 4Advanced Electronics Limited 18, 158, 309, 338,

359Advantronic Systems S.L. 160, 310, 339, 360AEI Cables Limited 429AGNI Devices PVT Ltd 163Aguilera Electronica S.L 163Ajax Chubb Varel B.V. 19Alarm Supply Pte Ltd 164Alberta Fire & Security Equipment Limited 4Alpha Fire Services W.L.L. 433AMPAC Europe Limited 20AMPAC Technologies PTY Ltd 21, 164, 310Apollo Fire Detectors Limited 167, 311, 339, 361Application Solutions (Safety and Security) Ltd,

East Sussex, United Kingdom 23Argus Fire Protection Company Limited 5Argus Security S.r.l. 177, 312, 340, 363Argus-Spectrum 180, 312, 341, 365ATEIS Middle East FZCO 183, 313, 341, 366ATOM KABLO SANAYI VE TICARET A.S. 433Autronica Fire & Security AS 341, 368BBahra Cables Company 434Bailey Maintenance 5Bangkok Cable Co Limited 435Banham Alarms (Prop

Banham Patent Locks Limited) 496Bardic by Honeywell (Novar Systems Ltd) 24, 185,

369BBC Fire Protection Limited 5Beijing Leader Huaxin Electronics Co. Ltd 186Bentel Security s.r.l. 313Biamp Systems Corporation 25Bosch Security Systems BV 27Bristol Fire Ltd 186, 313, 369BT Redcare 501Building Protection Systems (NI) Limited 27CCarillion (Novar Systems Ltd) 31Cavicel SpA 436Ceasefire Industries Ltd 187, 314, 369Channel Safety Systems Ltd 32Chiron Security Communications Limited 502Chubb Fire & Security 342Chubb Fire & Security Limited 5Chubb Fire and Security Limited 503Chubb Fire Ltd 188Clymac Limited 5Computionics Limited (Trading as C-Tec) 33Consilium Marine and Safety AB 188Context Plus Ltd 188, 314, 342, 438Control Equipment Limited 15, 37, 189Cooper Fulleon Limited 314, 370

Cooper Industries Inc 45, 315Cooper Lighting and Safety Ltd 46, 315, 371Cooper Safety 190Cooper Sécurité SAS 193Cranford Controls Limited 373CSL DualCom Limited 501CTM Fire and Security Limited (Leyland & London

Offices) 6DDaemon Fire and Security Limited 6Daksh Electronics Private Limited 194Dätwyler Cables 439Defensor Group Limited 6Detector Electronics Corporation 48, 195, 342Digital Security Controls, a Division of Tyco Safety

Products Canada Ltd 303Direction Fire Limited 6Doncaster Cables 440Draka (Malaysia) Sdn. Bhd. 441Draka UK Limited 442Dubai Cable Company (Private) Limited 446Dubai Cable Company (Private) Limited, Trading

as Ducab 447, 448EEland Cables 451EMCO 195, 316, 374EMCOR Facilities Services Limited, EMCOR

Specialist Services 6EMCS - East Midlands Central Station Limited 496Emergi-Lite Safety Systems (Thomas & Betts Ltd)

197, 316Emico Limited 7Emirates Fire Fighting Equipment Factory L.L.C.

(FIREX) 198, 316, 374, 452Eurotech Fire Systems Ltd 199, 317, 374Everday Technology Co. Limited 200, 317Eyston Company Ltd 303FFFE Fire & Security Limited 7Fike Safety Technology Ltd 50, 201, 317, 375Finder Elektronik A.S. 203, 318, 343, 377Fireblitz Extinguisher Ltd 303Fireguard Safety Equipment Co Ltd 205, 318, 377,

453Firelite by Honeywell (Pittway Systems

Technology Group (Europe) Ltd) 53, 206Fireonica Co. Ltd 206, 318Firesafe 54, 304Firetecnics Systems Limited 7FIREX Protection System Technology Ltd 55, 207,

319, 343, 378GGBE Fire & Security (a division of GB Electronics

Limited) 7Gent By Honeywell (Novar Systems Ltd) 56, 207,

319, 344, 378GEZE GmbH 211, 344Gira Giersiepen Gmbh & Co. KG 304

Page 9: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

INDEX

31 Dec 2012 ix

Global System Technology Plc 61, 212, 320, 344, 382

Grainger Fire Systems 7Group 4 Securicor Plc 63, 212, 320, 345, 382Grupo General Cable Sistemas, S.A. 453, 454Gulf Security Technology Co., Ltd. 65, 213, 320,

345, 383HHaes Systems Limited 68Hall & Kay Fire Engineering 8HDR 214, 321, 345, 383Hochiki America Corporation 215Hochiki Corporation 216Hochiki Europe (UK) Limited 216, 321, 346, 386Honeywell Automation (I) Pvt. Ltd 222Honeywell Control Systems Limited 224, 347Honeywell Control Systems Ltd 69, 226, 322, 347Honeywell International Inc 74Honeywell Life Safety Systems (Novar Systems

Ltd) 228Horing LIH Industrial Co Ltd 229, 322, 397Hosiden Besson Limited 397Huzhou Jiusheng Electric Co Ltd 455II.C. Service & Maintenance Limited 8Iceberg Building Services Limited 8Industrial Scientific Oldham 230INIM Electronics s.r.l. 232, 347Intelligent Safety & Security Technology Ltd. 233,

322Irish Driver-Harris Company Limited 456JJalo Helsinki Oy / Jalo Ltd 304Jaylow Supplies Ltd 460John Lewis Partnership 305KKAC Alarm Company Limited 323, 398Keystone Electric Wire & Cable Company Ltd 461Kidde Finland Oy 305Kidde Products Ltd 234, 348Kidde Products Ltd, trading as AirSense

Technology 235Kidde Safety Europe Ltd 305Kingfell Engineering Limited 8Kingfisher Security (UK) Limited trading as

Kingfisher Fire & Security 8KME Italy SpA 462LLabor Strauss Sicherungsanlagenbau GmbH 236,

327, 402LEONI Studer AG 463Lichfield Fire & Safety Equipment Co. Ltd

(LIFECO) 237Lloret Fire and Security Limited 8MM. J. Quinn Integrated Services Limited 9Mavili Elektronik Ticaret Ve Sanayi A.S. 75, 237MECE Fire & Security Limited 9Mercury Engineering 9MGC Systems Corp. 327

MICC (Shanghai) Electric Co Ltd 468Mineral Insulated Cable Co Ltd 470MITIE Technical Facilities Management Limited 9MITIE Technical Facilities Management Limited

(MITIE Fire and Security Systems) 9Morley-IAS Fire Systems By Honeywell 238Morley-IAS Fire Systems by Honeywell (Pittway

Systems Technology Group (Europe) Ltd) 79, 240, 328, 348, 403

MSA AUER 242Multron Systems Pte Ltd 82, 243, 328, 348, 407NNAJD ELECTRICALS & SAFETY EQUIPMENT

TRADING 471National Monitoring (Prop. AVR Group Limited)497Nexans Schweiz AG 471Nexans Turkiye Endustri ve Ticaret A.S. 472NG Bailey Limited - Rail Division 10Ningbo Siterwell Electronics Co., Ltd. 306Niscayah Limited 10Nitin Ventures FZE 83, 244, 329, 349, 407Nittan Europe Limited 245Norden Communication UK Ltd 473Notifier by Honeywell (Pittway Systems

Technology Group (Europe) Ltd) 16, 84, 246, 329, 349, 408

Notifier Fire Systems India 249OOlympia Electronics S.A. 89OLYMPIC CABLE COMPANY SDN. BHD. 473Oman Cables Industry (SAOG) 474Orient Corporation Pte. Ltd. 90PPanasonic Corporation 250, 349PEL Services Limited 10Pelco Finland Oy 91, 251, 330, 350, 410Philton Fire & Security Limited 253Photain Controls 93Pittway Tecnologica Srl. 254, 350Plana Fabrega 258Protec Fire Detection plc 10, 94, 258, 330, 351,

410Prysmian Cables & Systems Limited 475, 482RRAMCRO S.p.A 483SSabre Fire & Security Ltd 306Safety Technology International (Europe) Limited

330Safex Fire Services Limited 262Sareme UAB 263, 331Schlumberger Oilfield UK PLC, Sensor Highway

Limited (Schlumberger, Southampton) 264Schneider Electric Buildings Sweden AB 97Schneider Electronic Buildings AS 98Schrack Seconet AG 331Scotshield Limited 11Securiton AG 331Sensetech Systems Limited 11Shakun Polymers Limited 485

Page 10: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

INDEX

x 31 Dec 2012

Shanghai Mosafe Equipment Co.Ltd 306SHIELD FIRE, SAFETY AND SECURITY LTD 98,

264, 332, 351, 411, 485Siemens plc, Building Technologies, Fire Safety

Division 11Siemens Switzerland Limited, Building

Technologies Division 100, 265, 332, 352, 412SMS (Novar Systems Ltd) 108, 270, 333, 353, 413Southern Monitoring Services Limited 497Spectrex Inc 271Sprue Safety Products Ltd 306Static Systems Group Plc 11Sterling Safety Systems 273, 333, 354, 413Synaps Technology Srl 334System Sensor 275System Sensor Europe 276, 415System Sensor Europe, Life Safety Distribution

AG 416System Sensor, Honeywell International (I) PVT.

Limited 276TT V F (UK) Limited 11Tai Sin Electric Limited 486Talentum Developments Limited 279Tamlite Emergency & Fire 280Teledata S.r.l. 281, 334, 419TELE-FONIKA Kable Sp. z o.o., S.K.A. 487Texecom Ltd 420Thameside Fire Protection Co. Limited 12Thorn Security Limited, Trading as Tyco Safety

Product 110Thorn Security Limited, trading as Tyco Safety

Products 282, 334, 354, 422Tratos Cavi SpA 489

Trinity Protection Systems Limited 12Tyco Fire and Integrated Solutions (the trading

company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited) 12, 13

Tyco Thermal Controls Canada Limited 490Tyco Thermal Controls UK Ltd 491UUnion Cable Company Ltd 493UniPOS Ltd 287UTC Fire & Security (Africa) trading as Ziton 123UTC Fire & Security (Pty) LTD Trading as Ziton

124UTC Fire & Security BV 125, 288, 335, 355UTC Fire & Security BV. 503UTC Fire & Security Inc. Trading as Edwards

Systems Technology 151, 290, 336, 355, 423VVentcroft Limited 493Vimpex Limited 356, 424Vipond Fire Protection Limited 13Visonic 308VRC Terofire Products 292WWagner Group GmbH 293WebWayOne Ltd 504Weckx Handelsonderneming 308Wrexham Mineral Cables 494XXtralis Pty Limited 152, 295ZZarja Elektronika d.o.o 153Zeta Alarm Systems by GLT Exports Limited 154,

301, 308, 337, 357, 424

Page 11: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

Part1

FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS & CABLES

Page 12: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: FIRE DETECTION AND ALARM PRODUCTS, SYSTEMS &CABLES

2 31 Dec 2012

INTRODUCTION

A working fire detection and alarm system will increase the level of safety in a building by automatically warning occupants of fire before they would otherwise detect it.

To ensure the system works, the system must be designed correctly, products must be correctly selected and the systems must be correctly installed and maintained. It is recommended that all systems are designed, installed, commissioned and maintained by contractors who are approved by LPCB to LPS 1014 and that they are connected to Alarm Receiving Centres approved to LPS 1020.

Listings in this section include:

Products

Control and indicating equipment including voice alarm and power supplies Wireless, flame, beam, aspirating, smoke, heat and multi-sensor detectors Manual call points Line units including input and output devices Alarm warning devices including visual alarms, loudspeakers and sounders Cables Alarm transmission equipment Signalling systems

Products are approved in accordance with a range of standards. The details of these standards are given at the front of each section relevant to the product. Some of the above products may be hard wired or wireless (Radio link). Wireless products should also be approved to EN 54-25.

Systems

Fire detection and alarm systems are approved for system compatibility in accordance with: LPS 1054: Requirements and testing procedures for the approval and listing of component

compatibility for fire detection and alarm systems. EN 54 - Part 13: Compatibility assessment for system components.

Design, installation, commissioning and maintenance contractors

Contractors are approved in accordance with: LPS 1014: Requirements for certificated fire detection and alarm system firms. LPS 1020 - Alarm Receiving Centres

Page 13: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

31 Dec 2012 3

WHY USE AN LPS 1014 APPROVED COMPANY?Even with the best equipment, fire detection and alarm systems are only effective if correctly designed, installed, commissioned and serviced. It is therefore important that specifiers select only competent firms with a proven track record to undertake the work.

LPS 1014 Requirements for Certificated Fire Detection and Alarm System Firms meets these requirements in full.

LPS 1014 requires one encompassing Certificate of Conformity for the project, i.e. single point responsibility, which benefits all parties concerned, i.e. the insurer, the fire brigade, the building owner, etc. It is based on BS 5839-1 and also requires the use of third party approved products. For each system specifiers should request the issue of an LPCB Certificate of Conformity as part of the contract which:

certifies that the fire detection and alarm system was designed, installed and commissioned inaccordance with the installation rules applied, and

ensures that the system is recorded by LPCB as a certificated fire detection and alarm installation.

The availability of more varied and sophisticated fire detection and alarm equipment means that it is even more important that firms listed to LPS 1014 are regularly assessed by LPCB for their competence to design, install, commission and service fire detection and alarm systems in accordance with acceptable installation rules or codes of practice.

Additional officesWhere a firm has additional offices, each office must meet the requirements of LPS 1014 to be eligible for certification, and is separately listed.

Provisional ApprovalFirms with limited experience and track record can gain Provisional Approval in the LPS 1014 scheme. Their work is closely monitored by LPCB and when they have completed the requisite number of fire detection and alarm systems contracts over a period of not less than 2 years, and subject to satisfactory performance, they will be given full approval and listed in this section of the Red Book.

ADT Fire and SecuritySecurity House, The Summit, Hanworth Road, Sunbury on Thames, Middlesex TW16 5DB, United KingdomTel: +44 (0)1932 743456 • Fax: +44 (0)1932 743222

Certificate No. CFA-105 to LPS 1014

ADT Fire and SecurityADT House, 5th Avenue Business Park, Team Valley Trading Estate, Gateshead, Tyne and Wear NE11 0HF, United KingdomTel: +44 (0)191 451 5000 • Fax: +44 (0)191 487 9543

Certificate No. CFA-111 to LPS 1014

ADT Fire and SecurityUnit 5, Redwing Court Business Centre, Ashton Road, Romford, Essex RM3 8QQ, United KingdomTel: +44 (0)2082 724700 • Fax: +44 (0)2082 724709

Certificate No. CFA-112 to LPS 1014

Page 14: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

4 31 Dec 2012

ADT Fire and SecurityADT House, Tannochside Park, Uddingston, Glasgow G71 5PH, United KingdomTel: +44 (0)1698 486000 • Fax: +44 (0)1698 486100

Certificate No. CFA-113 to LPS 1014

ADT Fire and SecurityTyco Park, Grimshaw Lane, Newton Heath, Manchester M40 2WL, United KingdomTel: +44 (0)161 252 5500 • Fax: +44 (0)161 252 5688

Certificate No. CFA-109 to LPS 1014

ADT Fire and SecurityADT House, Mucklow Hill, Halesowen, Birmingham, West Midlands B62 8DA, United KingdomTel: +44 (0)1212 556000 • Fax: +44 (0)1212 556100

Certificate No. CFA-108 to LPS 1014

ADT Fire and Security180 Aztec West, Almondsbury, Bristol BS32 4TU, United KingdomTel: +44 (0)1454 843434 • Fax: +44 (0)1454 843484

Certificate No. CFA-107 to LPS 1014

ADT Fire and Securityc/o Hindle Cockburns Ltd, Victoria Road, Leeds LS11 9SX, United KingdomTel: +44 (0)1132 911000 • Fax: +44 (0)1132 425933

Certificate No. CFA-110 to LPS 1014

Alberta Fire & Security Equipment LimitedSan Gwakkin Road, Mriehel, BKR 3000, MaltaTel: +356 21 443538 • Fax: +356 21 484077E-mail: [email protected] • Website: www.alberta.com.mt

Certificate No. CFA-177 to LPS 1014

Page 15: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

31 Dec 2012 5

Argus Fire Protection Company LimitedHendglade House, 46 New Road, Stourbridge, West Midlands DY8 1PA, United KingdomTel: +44 (0)1384 376256 • Fax: +44 (0)1384 393955E-mail: [email protected] • Website: www.argusfire.co.uk

Certificate No. CFA-148 to LPS 1014

Bailey Maintenance7 Brown Lane West, Leeds LS12 6EH, United KingdomTel: +44 (0)113 234 3443 • Fax: +44 (0)113 222 3925E-mail: [email protected] • Website: www.baileymaintenance.co.uk

Certificate No. CFA-165 to LPS 1014

BBC Fire Protection LimitedSt Florian House, Ayton Road, Wymondham, Norfolk NR18 0QH, United KingdomTel: +44 (0)1953 857700 • Fax: +44 (0)1953 857750E-mail: [email protected] • Website: www.bbcfire.co.uk

Certificate No. CFA-126 to LPS 1014

Chubb Fire & Security Limited5 Canal Place, Armley Road, Leeds LS12 2DU, United KingdomTel: +44 (0)113 235 5131 • Fax: +44 (0)113 235 5132E-mail: [email protected] • Website: www.chubb.co.uk

Certificate No. CFA-120 to LPS 1014

Clymac LimitedCloudway Court, Belton Road, Loughborough LE11 1LW, United KingdomTel: +44 (0)1509 232651 • Fax: +44 (0)1509 232665E-mail: [email protected] • Website: www.clymac.co.uk

Certificate No. CFA-154 to LPS 1014

Page 16: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

6 31 Dec 2012

CTM Fire and Security Limited (Leyland & London Offices)Unit 2, Osprey Place, Moss Side Industrial Estate, Leyland PR26 7EW, United KingdomTel: +44 (0)800 5872753 • Fax: +44 (0)1772 641227E-mail: [email protected] • Website: www.firealarmuk.com

Including the following satellite offices:BBC Television Centre, Arch 118, Dodds Yard, Wood Lane, London W12 7RJTel: +44 (0)208 225 9427 • Fax: +44 (0)208 225 9446

Certificate No. CFA-156 to LPS 1014

Daemon Fire and Security LimitedDaemon House, 41-42 Albert Road, Tamworth, Staffs B79 7JS, United KingdomTel: +44 (0)1827 69266 • Fax: +44 (0)1827 53584E-mail: [email protected]

Certificate No. CFA-145 to LPS 1014

Defensor Group LimitedDefensor House, 15 Kingsley Street, Leicester LE2 6DY, United KingdomTel: +44 (0)116 244 8689 • Fax: +44 (0)116 244 8884E-mail: [email protected]

Certificate No. CFA-161 to LPS 1014

Direction Fire LimitedUnits 4 & 5 Fire Quarter, Blenheim Road, Epsom, Surrey KT19 9QN, United KingdomTel: +44 (0)1372 744499 • Fax: +44 (0)1372 741188E-mail: [email protected] • Website: www.directionfire.co.uk

Certificate No. CFA-178 to LPS 1014

EMCOR Facilities Services Limited, EMCOR Specialist ServicesPremier House, Tollgate, Eastleigh, Hampshire SO53 3YE, United KingdomTel: +44 (0)2380 648028 • Fax: +44 (0)2380 648191E-mail: [email protected] • Website: www.emcoruk.com

Certificate No. CFA-151 to LPS 1014

Page 17: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

31 Dec 2012 7

Emico LimitedAble House, 1 Figtree Hill, Hemel Hempstead, Hertfordshire HP2 5XL, United KingdomTel: +44 (0)1442 213111 • Fax: +44 (0)1442 236945E-mail: [email protected] • Website: www.emico.co

Certificate No. CFA-185 to LPS 1014

FFE Fire & Security Limited122 The Minories, London EC3 1NT, United KingdomTel: +44 (0)845 60 999 06 • Fax: +44 (0)20 8665 4125E-mail: [email protected] • Website: www.ffe.co.uk

Including the following satellite office at:Unit 20, Tait Road Industrial Estate, Tait Road, Croydon CR0 2DP

Certificate No. CFA-152 to LPS 1014

Firetecnics Systems LimitedFiretecnics House, 328 St James's Road, London SE1 5JX, United KingdomTel: +44 (0) 20 7587 0927 • Fax: +44 (0) 20 7740 3567E-mail: [email protected] • Website: www.firetecnics.com

Certificate No. CFA-146 to LPS 1014

GBE Fire & Security (a division of GB Electronics Limited)Unit C2, Elmbridge Court, Cheltenham Road East, Gloucester GL3 1JZ, United KingdomTel: +44 (0)845 1220884 • Fax: +44 (0)845 1220885E-mail: [email protected] • Website: www.gbe-uk.com

Certificate No. CFA-180 to LPS 1014

Grainger Fire SystemsThornley House, Carrington Business Park, Carrington, Manchester M31 4XL, United KingdomTel: +44 (0)161 777 6700 • Fax: +44 (0)161 777 6638E-mail: [email protected]

The following location is included within the scope of certification for servicing:Unit 1A, Newton Court, Wavertree Technology Park, Wavertree, Liverpool L13 1EJTel: +44 (0)151 220 4068 • Fax: +44 (0)151 259 4365

Certificate No. CFA-125 to LPS 1014

Page 18: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

8 31 Dec 2012

Hall & Kay Fire EngineeringSefton Lodge, Clewer Hill Road, Windsor, Berkshire SL4 4FT, United KingdomTel: +44 (0)1753 833444 • Fax: +44 (0)1753 833434E-mail: [email protected] • Website: www.hkfire.co.uk

Certificate No. CFA-147 to LPS 1014

I.C. Service & Maintenance LimitedUnit K3 Temple Court, Knights Park, Knight Road, Strood, Kent ME2 2LT, United KingdomTel: +44 (0)1634 290300 • Fax: +44 (0)1634 290700E-mail: [email protected] • Website: www.icservice.uk.com

Certificate No. CFA-158 to LPS 1014

Iceberg Building Services Limited1 Station Court, Station Approach, Wickford, Essex SS11 7AT, United KingdomTel: +44 (0)1268 739450 • Fax: +44 (0)1268 739439E-mail: [email protected] • Website: www.icebergbuildingservices.co.uk

Certificate No. CFA-175 to LPS 1014

Kingfell Engineering LimitedPO Box 64222, Barnby Street, London NW1 2RS, United KingdomTel: +44 (0)203 2145252 • Fax: +44 (0)2032145253/5E-mail: [email protected] • Website: www.kingfellengineering.com

Certificate No. CFA-138 to LPS 1014

Kingfisher Security (UK) Limited trading as Kingfisher Fire & Security1 Riverside Industrial Estate, Dogflud Way, Farnham GU9 7UG, United KingdomTel: +44 (0)1252 710809 • Fax: +44 (0)1252 710816E-mail: [email protected] • Website: www.kingfishersecurity.co.uk

Certificate No. CFA-176 to LPS 1014

Lloret Fire and Security Limited24 Ullswater Crescent, Ullswater Business Park, Coulsdon, Surrey CR5 2HR, United KingdomTel: +44 (0) 208 410 4600 • Fax: +44 (0) 208 668 9141E-mail: [email protected] • Website: www.lloret.co.uk

Certificate No. CFA-181 to LPS 1014

Page 19: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

31 Dec 2012 9

M. J. Quinn Integrated Services LimitedOak House, Overbrook Lane, Knowsley Business Park, Knowsley, Merseyside L34 9FB, United KingdomTel: +44 (0)151 547 8800 • Fax: +44 (0)151 547 8801E-mail: [email protected] • Website: www.mjquinn.co.uk

Certificate No. CFA-137 to LPS 1014

M. J. Quinn Integrated Services Limited5th Floor, 119 Farringdon Road, London EC1R 3DA, United KingdomTel: +44 (0)207 239 8750 • Fax: +44 (0)207 239 8751E-mail: [email protected] • Website: www.mjquinn.co.uk

Certificate No. CFA-143 to LPS 1014

MECE Fire & Security LimitedCourtlodge, Kemsley Street Road, Bredhurst, Gillingham, Kent ME7 3LS, United KingdomTel: +44 (0)1634 260607 • Fax: +44 (0)1634 260278E-mail: [email protected] • Website: www.mecefireandsecurity.co.uk

Certificate No. CFA-159 to LPS 1014

Mercury EngineeringMercury House, Sandyford Industrial Estate, Foxrock, Dublin 18, IrelandTel: +353 1 216 3000 • Fax: +353 1 216 3006E-mail: [email protected] • Website: www.mercury.ie

Certificate No. CFA-174 to LPS 1014

MITIE Technical Facilities Management LimitedLimeharbour Court, 5 Limeharbour, London E14 9RH, United KingdomTel: +44 (0)20 7001 7000 • Fax: +44 (0)20 7001 7272E-mail: [email protected] • Website: www.mitie.com

Certificate No. CFA-129 to LPS 1014

MITIE Technical Facilities Management Limited (MITIE Fire and Security Systems)MITIE House, 61-63 Kepler, Lichfield Road Industrial Estate, Tamworth B79 7XE, United KingdomTel: +44 (0)1827 309791 • Fax: +44 (0)1827 313480E-mail: [email protected] • Website: www.mitie.com

Certificate No. CFA-163 to LPS 1014

Page 20: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

10 31 Dec 2012

NG Bailey Limited - Rail Division3rd Floor Angel Building, 407 St John's Street, London EC1V 4AB, United KingdomTel: +44 (0)20 7843 0200 • Fax: +44 (0)20 7843 0201E-mail: [email protected] • Website: www.ngbailey.co.uk

Certificate No. CFA-186 to LPS 1014

Niscayah LimitedRoding House, 970 Romford Road, London E12 5LP, United KingdomTel: +44 (0)20 8553 5932 • Fax: +44 (0)20 8478 8052E-mail: [email protected] • Website: www.niscayah.co.uk

Certificate No. CFA 169 to LPS 1014

PEL Services LimitedBelvue Business Centre, Belvue Road, Northolt, Middlesex UB5 5QQ, United KingdomTel: +44 (0)20 8839 2100 • Fax: +44 (0)20 8841 1948E-mail: [email protected] • Website: www.pel.co.uk

Certificate No. CFA-179 to LPS 1014

Protec Fire Detection plcProtec House, Churchill Way, Nelson, Lancashire BB9 6RT, United KingdomTel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273E-mail: [email protected] • Website: www.protec.co.uk

Including the following satellite offices:Unit 4, White Oak Square, London Road, Swanley, Kent BB8 1AG, United KingdomTel: +44 (0)845 456 5394 • Fax: +44 (0)845 456 5395

Unit 10, Fulcram 4, Solent Way, Whiteley, Fareham, Hampshire PO15 7FT, United KingdomTel: +44 (0)845 456 5392 • Fax: +44 (0)845 456 5393

5 Morston Court, Blakeney Way, Kingswood Lakeside, Cannock, Staffordshire WS11 8JB, United KingdomTel: +44 (0845 456 5398 • Fax: +44 (0845 456 5399

Unit 1, Ashfield Court, Whitehall Road, Leeds LS12 5JB, United KingdomTel: +44 (0)845 456 53388 • Fax: +44 (0)845 456 53389

Certificate No. CFA-132 to LPS 1014

Page 21: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

31 Dec 2012 11

Scotshield LimitedCentury House, Chapelhall Industrial Estate, Airdrie, Scotland ML6 8QH, United KingdomTel: +44 (0)1236 767788 • Fax: +44 (0)1236 762233E-mail: [email protected]

Including the following satellite office for service work onlyUnit 2, 9 Lotland Street, Inverness ML1 8QHTel: +44 (0)1463 709637 • Fax: +44 (0)1463 709638

Certificate No. CFA-150 to LPS 1014

Sensetech Systems LimitedLangdale House, 11 Marshalsea Road, London SE1 1EN, United KingdomTel: +44 (0)845 689 9099 • Fax: +44 (0)207 8633238E-mail: [email protected] • Website: www.sensetechsystems.co.uk

Certificate No. CFA-184 to LPS 1014

Siemens plc, Building Technologies, Fire Safety DivisionBrunel House, Sir William Siemens Square, Frimley, Camberley, Surrey GU16 8QD, United KingdomTel: +44 (0)1276 696000 • Fax: +44 (0)1276 696133E-mail: [email protected] • Website: www.siemens.co.uk/buildingtechnologies

Certificate No. CFA-100 to LPS 1014

Static Systems Group PlcHeath Mill Road, Wombourne, Staffordshire WV5 8AN, United KingdomTel: +44 (0)1902 895551 • Fax: +44 (0)1902 324969E-mail: [email protected] • Website: www.staticsystems.co.uk

Certificate No. CFA-135 to LPS 1014

T V F (UK) Limited59-69 Queens Road, High Wycombe, Buckinghamshire HP13 6AH, United KingdomTel: +44 (0)1494 450641 • Fax: +44 (0)1494 465378E-mail: [email protected] • Website: www.tvfltd.co.uk

Certificate No. CFA-128 to LPS 1014

Page 22: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

12 31 Dec 2012

Thameside Fire Protection Co. LimitedUnit 4, Sovereign Business Park, Cranes Farm Road, Basildon, Essex SS14 3JD, United KingdomTel: +44 (0)1268 597999 • Fax: +44 (0)1268 597998E-mail: [email protected] • Website: www.thamesidefire.co.uk

Certificate No. CFA-171 to LPS 1014

Trinity Protection Systems LimitedLittle Bridge Business Park, Oil Mill Lane, Clyst St.Mary, Exeter, Devon EX5 1AG, United KingdomTel: +44 (0)1392 874455 • Fax: +44 (0)1392 875546E-mail: [email protected] • Website: www.trinityprotection.co.uk

Certificate No. CFA-160 to LPS 1014

Trinity Protection Systems LimitedUnit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 INP, United KingdomTel: +44 (0)1926 485080 • Fax: +44 (0)1926 485090E-mail: [email protected] • Website: www.trinityprotection.co.uk

Certificate No. CFA-167 to LPS 1014

Trinity Protection Systems Limited180 Milton Park, Abingdon, Oxfordshire OX14 4SE, United KingdomTel: +44 (0)1235 862456 • Fax: +44 (0)1235 834450E-mail: [email protected] • Website: www.trinityprotection.co.uk

Certificate No. CFA-168 to LPS 1014

Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)Hillcrest Business Park, Cinderbank, Dudley, West Midlands DY2 9AP, United KingdomTel: +44 (0)1384 458993 • Fax: +44 (0)1384 458981Website: www.tycofis.com

Certificate No. CFA-103 to LPS 1014

Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)1610 Park Avenue, Aztec West, Almondsbury, Bristol BS32 4UA, United KingdomTel: +44 (0)1454 240071 • Fax: +44 (0)1454 626443Website: www.tycofis.com

Certificate No. CFA-170 to LPS 1014

Page 23: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 1LPS 1014 CERTIFIED FIRE DETECTION AND ALARM SYSTEM FIRMS

31 Dec 2012 13

Tyco Fire and Integrated Solutions (the trading company for Tyco Fire and Integrated Solutions (UK) Limited and Tyco Fire and Integrated Solutions (Ireland) Limited)Tyco House, 57-63 Farnham Road, Slough, Berkshire SL1 3TN, United KingdomTel: +44 (0)1753 574111 • Fax: +44 (0)1753 824226Website: www.tycofis.com

Certificate No. CFA-157 to LPS 1014

Vipond Fire Protection Limited10-12 Glenfield Road, Kelvin Industrial Estate, East Kilbride, Lanarkshire G75 0RA, United KingdomTel: +44 (0)1355 2375 25/80/88 • Fax: +44 (0)1355 263399E-mail: [email protected] • Website: www.vipondfire.co.uk

Certificate No. CFA-173 to LPS 1014

Page 24: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 2FIRE DETECTION AND ALARM SYSTEMS

14 31 Dec 2012

A fire detection and fire alarm system is typically made up of a number of inter-linked components including detectors, manual call points, and alarm sounders connected to control and indicating equipment by means of one or more transmission paths. All system components, including the control and indicating equipment are also connected to a power supply directly or indirectly.

A fire detection and alarm system may be linked to other systems such as fire protection, or building management systems. These other systems are not considered as part of the fire detection and alarm systems.

The fire detection and alarm systems may be networked together.

Each of the components that constitute the fire detection and alarm system may be individually tested and approved against their appropriate standard to demonstrate their own performance and reliability but in order to ensure their compatibility and performance together within the system, certain system tests and requirements must be fulfilled.

The system standard specifies the requirements for compatibility and connectability assessment of system components that either comply with the requirements of EN 54 and/or with a manufacturer’s specification. The standard also includes requirements for the integrity of the fire detection and fire alarm system when connected to other systems.

This section lists approved fire detection and alarm systems suitable for use in buildings for the protection of people and property. The system requirements ensure the compatibility of the different components of the system work reliably together. Each component of the fire detection and alarm systems listed in this section are approved to the applicable product standard and are listed in Sections 3, 4.1, 5, 6, and 7. The approval process for the system is outlined in scheme document SD040.

Systems listed in this section have been approved to LPS 1054: 2001 Requirements for the evaluation of component compatibility for fire alarm systems

This standard was designed for the UK market and applies to systems incorporating control and indicating equipment and power supply equipment complying with EN 54-2 Fire detection and fire alarm systems -Control and indicating equipment and EN 54-4 Fire detection and fire alarm systems - Power supplyequipment respectively.

Networked systems are evaluated by ensuring that each control panel connected to the network can operate as a stand alone unit, in the event of failure of the network connections, and that failure of a control panel will not affect other control panels on the network.

LPCB is now accepting products for approval to EN 54-13: 2005 Compatibility assessment for system components which is applicable to the EU market and to LPS 1653: 2011 Requirement for Network fire detection and alarm systems.

Note: Since LPCB uses national and international standards for the listing of products, in some instances, the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

Page 25: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 2FIRE DETECTION AND ALARM SYSTEMS

31 Dec 2012 15

Control Equipment LimitedHillcrest Business Park, Dudley, West Midlands DY2 9AP, United KingdomTel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972E-mail: [email protected] • Website: www.controlequipment.com

Certificate No: 018b to LPS 1054-1Certificate No: 018d to LPS 1054-1

Certificated Products LPCB Ref. No.

Precept fire alarm system Comprising the following products:

Control Equipment LimitedPrecept 2, 4, 8, 16 and 32 zone control and indicating equipment.

Apollo Fire Detectors Limited55000-100 grade 1 rate of rise heat detector (45681-200 base)55000-200 ionization smoke detector (45681-200 base)55000-300 photoelectic smoke detector (45681-200 base)53531-221 grade 1 rate of rise heat detector (45681-007 base) continued53541-151 ionization smoke detector (45681-007 base)53541-200 photoelectric smoke detector (45681-007 base)55000-101 grade 2 rate of rise heat detector (45681-200 base)55000-102 grade 3 rate of rise heat detector (45681-200 base)55000-103 range 1 rate of rise heat detector (45681-200 base)55000-104 range 2 rate of rise heat detector (45681-200 base)55000-210 integrating ionization smoke detector (45681-200 base)

Hochiki CorporationDFE-60 grade 2 fixed temperature heat detector (YBF-RL/4H5 base)DFE-90 range 1 fixed temperature heat detector (YBF-RL/4H5 base)DCC-1EL grade 1 rate of rise heat detector (YBF-RL/4H5 base)DCC-2EL grade 2 rate of rise heat detector (YBF-RL/4H5 base)DCC-R1EL range 1 rate of rise heat detector (YBF-RL/4H5 base)

Hochiki EuropeSLK-E photoelectric smoke detector (YBF-RL/4H5 base)SIH-E ionization smoke detector (YBF-RL/4H5 base)

KAC Alarm Company LimitedKR72 manual call point.

Photain Controls LimitedISD-P91 ionization smoke detectorPRR-P91 grade 1 rate of rise heat detectorPHD-P90 range 1 fixed temperature heat detector

Signature Industries - Clifford and Snell Alarms.MCP/R/F manual call pointMCP/R/S manual call point

System Sensor, St. Charles, Illinois, USA.1151E ionization smoke detector (B401 base)2151E photoelectric smoke detector (B401 base)

018b/S1

Discovery fire alarm system

Comprising the following products:

Control Equipment LimitedDiscovery analogue addressable control and indicating equipment

Apollo Fire Detectors Limited55000-400 grade 2 analogue temperature monitor55000-420 grade 2 analogue temperature monitor58000-400 Discovery temperature monitor55000-600 analogue photoelectric smoke monitor55000-620 analogue photoelectric smoke monitor58000-600 Discovery optical smoke monitor55000-500 analogue ionisation smoke monitor55000-520 analogue ionisation smoke monitor58000-500 Discovery ionisation smoke monitor58000-700 Discovery multisensor monitor55000-900 surface and flush mounted manual call point55000-910 flush mounted manual call point55000-950 waterproof addressable manual call point58000-900 flush and surface mounted manual call point58000-910 flush mounted manual call point58000-920 surface mounted manual call point

018d/01

Page 26: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 2FIRE DETECTION AND ALARM SYSTEMS

16 31 Dec 2012

Certificated Products LPCB Ref. No.

55000-700 XP95 short circuit isolator45681-321 XP95 negative isolating base45681-210 XP95 addressable mounting base

Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.notifierfiresystems.co.uk

Certificate No: 154e to lps 1054: Issue 2.1

Certificated Products LPCB Ref. No.

Notifier NFS2-8 Fire Alarm System

Comprising the following products:

Notifier Fire Systems Ltd 124-345-002 NFS2-8, 2 Zone Conventional Control and Indicating Equipment 124-345-004 NFS2-8, 4 Zone Conventional Control and Indicating Equipment 124-345-008 NFS2-8, 8 Zone Conventional Control and Indicating Equipment

Morley-IAS Fire Systems ECO 1002 Photoelectric smoke and heat detector ECO 1003 Photoelectric smoke detector ECO 1004T High Temperature 78C heat detector class BS ECO 1005 Heat detector class A1R ECO 1005T Fixed temperature heat detector class A2S

KAC Alarm Company LtdMCP1A-Rxxxxx Indoor/outdoor surface/flush mounting conventional manual call point NS4/R Sounder 4 tone wall mounting conventional (red) NS4/W Sounder 4 tone wall mounting conventional (white) NS14/R Sounder 14 tones wall mounting conventional (red) NS14/W Sounder 14 tones wall mounting conventional (white)

154e/S1

Page 27: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 17

Control and Indicating Equipment (CIE) is a component of a fire detection and alarm system through which other components may be connected to it such as detectors, manual call points, sounders, routing equipment, voice alarm equipment and fire protection equipment. It is supplied with power from power supply equipment which may be housed within the CIE enclosure or a separate enclosure.

CIE is used to receive and send out signals that are related to fire. CIE also monitors the system for faults (short and open circuit or power supply faults) and indicates the status of the fire detection and alarm system.

CIE designed to meet a European standard such as EN 54-2 or international standard such as ISO 7240-2 has certain options with requirements. For example, it may be designed to provide a signal to fire protection equipment or have dependencies on more than one alarm signal. Some CIEs have other functions which are not specified in the standard. These additional features are normally assessed such that they do not jeopardise compliance.

The choice of CIE is dependent on the specific applications as recommended in the application guidelines for a specific job or building.

Some CIEs have associated repeaters or mimic panels. These are normally used to repeat the indications given on the main CIE and sometimes they have control functions such as silencing sounders. There are no published standards that these repeaters or mimics can be tested against.

Voice Alarm Control and Indicating Equipment (VACIE) is a component of the fire alarm system which receives signals from the CIE or via manual control in order to activate messages via loudspeakers. VACIE may also include emergency microphone to broadcast live messages. The approval processes for this type of equipment is outlined in scheme document SD040.

This section lists Control and Indicating Equipment, Voice Alarm Control and Indicating Equipment and power supply equipment approved for use in fire detection and fire alarm systems in buildings. Repeaters or mimics that are listed in this section are only approved with their associated CIE and are subjected to the same environmental tests as the CIE. The approval processes for this type of equipment is outlined in scheme document SD040.

Products listed in this section have been approved to: EN 54-2: 1997 Control and Indicating Equipment; EN 54-2: 1997 + A1: 2006 Control and Indicating Equipment; EN 54-4: 1997 Power supply equipment; EN 54-4: 1997 + A1: 2002 and A2: 2006 Power supply equipment;

ISO 7240-2: 2003 Control and Indicating Equipment;

ISO 7240-4: 2003 Power supply equipment; EN 54-16:2008 Voice Alarm Control and Indicating Equipment.

Audit:Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard.

Notes:1. EN 54-2: 1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that control and Indicating Equipment are certificated to EN 54-2: 1997 + A1: 2002

2. EN 54-4: 1997 is a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 August 2009. It is therefore recommended that power supply equipment are certificated to EN 54-4: 1997 + A1: 2002 and A2: 2006.

3. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We

Page 28: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

18 31 Dec 2012

recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

4. Where the Control and Indicating Equipment is of modular construction, and the use of certain modules (or printed circuit boards PCBs) is optional, these are listed with the applicable equipment.

Advanced Electronics Limited34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United KingdomTel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222E-mail: [email protected] • Website: www.Advel.co.uk

Certificate No: 018c to EN 54:Part 2 and 4: 1997

Certificated Products LPCB Ref. No.

Mx-1002 2 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/02

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Mx-1004 4 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/03

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Mx-1008 8 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/04

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Mx-1016 16 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/05

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Mx-1032 32 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1629 Display board C1632 16 Zone Expansion board C1652 5A Power supply board

018c/06

Page 29: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 19

Certificated Products LPCB Ref. No.

C1631 Repeater interface board (option)Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Mx-1108 8 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface board

018c/R01

Mx-1116 16 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface board

018c/R02

Mx-1132 32 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1629 Display board C1631 Repeater interface board

018c/R03

Ajax Chubb Varel B.V.Cruquiusweg 118, 1019 AK, Amsterdam, The NetherlandsTel: +31205909500 • Fax: +31205909599E-mail: [email protected] • Website: www.ajaxchubbvarel.nl

Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

809-250450 Two zone conventional control and indicating equipment

Incorporating the units:

RPF0702005 Power supply PCBSPF0724851 2 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/10

809-250451 Four zone conventional control and indicating equipment

Incorporating the units:

RPF0702005 Power supply PCBSPF0724853 4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/11

809-250452 Eight zone conventional control and indicating equipment

Incorporating the units:

RPF0702005 Power supply PCBSPF0724855 8 Zone main control board

176b/12

Page 30: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

20 31 Dec 2012

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

AMPAC Europe LimitedUnit 18 Networkcentre, Yorkshire Way, Westmoor Park, Doncaster, South Yorkshire DN3 3GW, United KingdomTel: +44 (0)1302 833522 • Fax: +44 (0)1302 835021E-mail: [email protected] • Website: www.ampac.net

Certificate No: 952a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

LoopSense 8281-0105 One loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA Main Termination Board BRD82ZICC Zone Interface & Control Card PSU2397 Power Supply Unit ASS82ZICC Zone Indicator & LCD Assembly (8210)

Certificated with the following options with requirements from EN54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

966a/01

Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

LoopSense 8281-0205 Two loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA Main Termination BoardBRD82ZICC Zone Interface & Control CardPSU2397 Power Supply Unit 8210-0001 2nd loop activation Key BRD82LSD Loop Activation BoardASS82ZICC Zone Indicator & LCD Assembly (8210)

Certificated with the following options with requirements from EN54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point

966a/02

Page 31: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 21

Certificated Products LPCB Ref. No.

10 Test conditionNote: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

AMPAC Technologies PTY Ltd7 Ledgar Road, Balcatta 6021, AustraliaTel: +618 (9242) 3333 • Fax: +618 (9242) 3334E-mail: [email protected] • Website: www.ampac.net

Certificate No: 966a to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 966b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1998 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

LoopSense 8281-0105 One loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA Main Termination BoardBRD82ZICC Zone Interface & Control CardPSU2397 Power Supply Unit ASS82ZICC Zone Indicator & LCD Assembly (8210)

Certificated with the following options with requirements from EN54-2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

966a/01

Note:1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

LoopSense 8281-0205 Two loop, 32 Zone analogue addressable control and indicating equipment.

Incorporating the following units:

BRD82MBA Main Termination BoardBRD82ZICC Zone Interface & Control CardPSU2397 Power Supply Unit 8210-0001 2nd loop activation Key BRD82LSD Loop Activation BoardASS82ZICC Zone Indicator & LCD Assembly (8210)

Certificated with the following options with requirements from EN54-2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

966a/02

Note: 1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

Page 32: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

22 31 Dec 2012

Certificated Products LPCB Ref. No.

8681-0108 FireFinder Plus One loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)BRD86DLTB4-A FFP Dual loop termination board (8610)BRD86FPB5-B FFP Front panel board EN54 (8610)BRD86MBA4-A FFP Main board LCD (8610)BRD86MCPU4-B FFP Main 64MB CPU card (8610)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)PSU1888 Power supply 5A (8610)

Optional Modules:BRD43EZC2-A 8 Zone conventional module (4310)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routine equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

966b/01

8681-0208 FireFinder Plus Two loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)BRD86DLTB4-A FFP Dual loop termination board (8610)BRD86FPB5-B FFP Front panel board EN54 (8610)BRD86MBA4-A FFP Main board LCD (8610)BRD86MCPU4-B FFP Main 64MB CPU card (8610)BRD86SCB3-A FFP Slave CPU card (8610)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)PSU1888 Power supply 5A (8610)

Optional Modules:BRD43EZC2-A 8 Zone conventional module (4310)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routine equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

966b/02

8681-0308 FireFinder Plus Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)BRD86DLTB4-A FFP Two Dual loop termination boards (8610)BRD86FPB5-B FFP Front panel board EN54 (8610)BRD86MBA4-A FFP Main board LCD (8610)BRD86MCPU4-B FFP Main 64MB CPU card (8610)BRD86SCB3-A FFP Two Slave CPU cards (8610)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)PSU1888 Power supply 5A (8610)

Optional Modules:

966b/03

Page 33: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 23

Certificated Products LPCB Ref. No.

BRD86DLTB4-A FFP Dual loop termination board (8610)BRD86SCB3-A FFP Slave CPU cards (8610)BRD43EZC2-A 8 Zone conventional module (4310)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routine equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

8681-0408 FireFinder Plus Four loop, 32 Zone analogue addressable control and indicating equipment

Incorporating as modular units:

BRD68BPSC4-A FFP Brigade & Power supply control board (8610)BRD86DLTB4-A FFP Two Dual loop termination boards (8610)BRD86FPB5-B FFP Front panel board EN54 (8610)BRD86MBA4-A FFP Main board LCD (8610)BRD86MCPU4-B FFP Main 64MB CPU card (8610)BRD86SCB3-A FFP Three Slave CPU cards (8610)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)PSU1888 Power supply 5A (8610)

Optional Modules:BRD86DLTB4-A FFP Dual loop termination board (8610)BRD86SCB3-A FFP Slave CPU cards (8610)BRD43EZC2-A 8 Zone conventional module (4310)BRD43ZAMC2-A 32 Zone alarm MIMIC internal card (4310)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routine equipment7.11 Delay to outputs7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C8.3 Fault signal from points8.9 Output to fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

966b/04

Application Solutions (Safety and Security) Ltd, East Sussex, United KingdomUnit 17 Cliffe Industrial Estate, Lewes, East Sussex BN8 6JL, United KingdomTel: +44 (0) 1273 405411 • Fax: +44(0) 1273 405415E-mail: [email protected] • Website: www.asl-control.co.uk

Certificate No: 1043a to EN 54-16: 2008 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

ASL Rack mount voice alarm system

Incorporating the following modules:VAR8-ACU(EN54) Network master 8x8 routerVAR8(EN54) Standalone 8x8 routerVAR8-E(EN54) Standalone 8x8 router with expansion boardVAR4(EN54) Standalone 4x4 routerVAR12(EN54) Standalone 12x12 router

1043a/01

Page 34: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

24 31 Dec 2012

Certificated Products LPCB Ref. No.

VAR20(EN54) Standalone 20x20 routerVAR-NIA Network Interface Adaptor

VAR8 Optional modules:EFI01 Analogue input and digital output boardGENT Interface Interface for VAR8-E to GENT Fire LoopVAR-ANIC Network interface for VAR8(EN54), VAR8-E(EN54) and

VAR8-ACU(EN54)VAR8-EXP8 Converts VAR8(EN54) to VAR8-E(EN54)

V400 Amplifier frame:V400 Amplifier frame for housing M series amplifiers and amplifier interfaces

M series amplifiers:M100 100W AmplifierM200 200W AmplifierM400 400W Amplifier

Amplifier interfaces for V400 mainframe:LSDDC Dual DC line surveillance interface with loop return optionSSINT Standby amplifier interface

X400 Amplifier frame:X400 Amplifier frame for housing MX series amplifiers

MX series amplifiers:MX100 100W AmplifierMX200 200W AmplifierMX400 400W Amplifier

Power supply:BPC65 65AH output power supplyBPC130 130AH Output power supplyBDIST Battery distribution terminals

MDIST Main distribution panel

Optional modules:BMB01 Remote I/O expander unitFMS1 Firemans microphone - All callFMS5 Zoneable Firemans remote microphone - 5 buttonsFMS10 Zoneable Firemans remote microphone - 10 buttonsFMS20 Zoneable Firemans remote microphone - 20 buttonsEMS01 Emergency microphone and accessible Mimic display for routersEMS01-EC Emergency microphone and accessible Mimic display for routers

with euro-cylinder lockEMS01-MT EMS01 with an all-call button used to trigger an evacuation

messageEAP01 Emergency access point - All call emergency microphoneMT01 Voice alarm manual trigger

Certified with the following options with requirements from EN 54 Part 16:7.9 Voice alarm condition output8.3 Indication of faults related to the transmission path to the CIE

(Not applicable on the GENT Interface)10.1 Voice Alarm Manual control12 Emergency microphone(s)13.14 Redundant power amplifiers

Page 35: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 25

Bardic by Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United KingdomTel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210Website: www.bardic.co.uk

Certificate No: 154g-(cl-3) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

Zircon 2 Zone 002-509-229 Bardic Zircon, 2 zone, region 2, black grey 154g/06Incorporating the following units:020-747 8-way relay kit020-772 4-way monitored sounder kit

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment10 Test condition

Zircon 4 Zone 002-509-249 Bardic Zircon, 4 zone, region 2, black grey 154g/07Incorporating the following units:020-747 8-way relay kit020-772 4-way monitored sounder kit

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment10 Test condition

Zircon 8 Zone 002-509-289 Bardic Zircon, 8 zone, region 2, black grey 154g/08Incorporating the following units:020-747 8-way relay kit020-772 4-way monitored sounder kit

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment10 Test condition

Page 36: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

26 31 Dec 2012

Biamp Systems Corporation9300 S.W. Gemini Drive, Beaverton, Oregon 97008, USATel: +1 503 718 9212 • Fax: +1 503 626 0281Website: www.biamp.com

Certificate No: 977a to EN 54-16: 2008

Certificated Products LPCB Ref. No.

Vocia VACIE Voice Alarm Control and Indicating Equipment

Incorporating:LSI-16 / LSI-16e Life Safety Interface: 700-P630-9 LSI-16 / LSI-16e Main Board 700-P632-9 LSI-16 / LSI-16e Display Board 700-P675-9 IM-16 Input Module 700-P644-9 LSI-16 / LSI-16e Power Supply Board

VA-8600c Amplifier: 700-0646-9 VA-8600 AM-600c Amplifier Module 700-0601-9 VA-8600 NM-1 Network Module 700-0598-9 VA-8600 Back Plane Board 700-0599-9 VA-8600 Power Supply Board 700-0633-9 VA-8600 Capacitor Board 700-0629-9 VA-8600 AC Inlet Board 700-0602-9 VA-8600 Display Board 700-P622-9 VA-8600 Device ID Board 700-P800-9 VFOM-1 Voice Fail Over Module

VA-4030e Amplifier: 700-0675-9 VPA-1 Amplifier Module 700-0677-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-0687-9 VAS-1 Aux DC Power Supply 700-0672-9 EIC-4 Input Module 700-P681-9 VAD-1 Display Board

VA-4030 Amplifier: 700-0675-9 VPA-1 Amplifier Module 700-0677-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-P684-9 VAD-2 Display Board

VA-2060e Amplifier: 700-0676-9 VPA-2 Amplifier Module 700-0686-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-0687-9 VAS-1 Aux DC Power Supply 700-0689-9 EIC-2 Input Module 700-P685-9 VAD-3 Display Board

VA-2060 Amplifier: 700-0676-9 VPA-2 Amplifier Module 700-0686-9 VSW-1 Transformer Switch Board 700-P680-9 VNM-1 Network Module 700-P686-9 VAD-4 Display Board

WS-4 (EWS-4) Paging Micro phone: 700-P625-9 WS Main Board 700-P676-9 WS-4 (EWS-4) Switch Board

WS-10 (EWS-10) Paging Microphone: 700-P625-9 WS Main Board 700-P776-9 WS-10 (EWS-10) Switch Board

CI-1 Control Interface: 700-P669-9 CI-1 Main Board

977a/01

Page 37: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 27

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54-16: 7.3 Audible warning 7.5 Phased evacuation 7.9 Voice alarm condition output 8.3 Indication of faults related to the transmission path to the CIE 12 Emergency microphone 13.14 Redundant power amplifiers

Note: The certification is conditional upon the Vocia VACIE being supplied with power from power supplies that meet the specifications detailed in the VOCIA Reference Guide, and comply with the requirements of EN 54-4.

Bosch Security Systems BVKapittelweg 10, 4827 HG Breda, The NetherlandsTel: +31 76 5721 240 • Fax: +31 76 5716 626E-mail: [email protected] • Website: www.boschsecurity.com

Certificate No: 1054a-(cl-1) to EN 54-16: 2008

Certificated Products LPCB Ref. No.

PROMATRIX 8000 Voice Alarm System

Incorporating the following modules:DPM 8016 Promatrix controllerDPM AO-1 Analog audio output moduleDPM UI-1 Universal audio input moduleDPA 8150 1 x 500W Power amplifierDPA 8225 2 x 250W Power amplifierDPA 8412 4 x 125W Power amplifierDPC 8015 Call stationNRS90231 key lock switchEB DPC Emergency button DPC 8000 seriesDPC 8120 Call station extensionLBB1965 Plena message managerPLN-1EOL END OF LINE BOARD EOL 8001 END OF LINE BOARD

Certified with the following options with requirements from EN 54 Part 16:

7.6.2 Manual silencing of the voice alarm condition7.7.2 Manual reset of the voice alarm condition7.9 Voice alarm condition output8.3 Indication of faults related to the transmission path to the CIE8.4 Indication of faults related to voice alarm zones10 Voice alarm manual control12 Emergency microphone(s)

Note: The certification is conditional upon the PROMATRIX 8000 being supplied with power from power supplies that meet the specifications detailed in the DPM 8016 PROMATRIX CONTROLLER Owners Manual, and which complies with the requirements of EN 54-4.

1054a/01

Building Protection Systems (NI) Limited1 Pilot's View, Sydenham Business Park, Heron Road, Belfast Harbour Estate, Belfast BT3 9LE, IrelandTel: 00442890455111 • Fax: 00442890466111E-mail: [email protected] • Website: www.bpsni.co.uk

Certificate No: 154g-(cl-4) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006

Page 38: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

28 31 Dec 2012

Certificated Products LPCB Ref. No.

Mach 2.8 Basic Equipment Kit, (BEK): Modular analogue addressablecontrol and indicating equipment020-538-501 Basic Equipment Kit, Group 0

Incorporating the following as modular units:

Enclosures:020-472-009 Backbox Kit Standard020-473-009 Backbox Kit Extended, Black / Grey020-474-009 Backbox Kit Extended Deep, Black / Grey020-475-009 Backbox Kit Double Extended, Black / Grey020-476-009 Backbox Kit Double Extended Deep, Black / Grey020-480-501 Cover Kit Main Moulded, Black / Grey020-481-009 Cover Kit Extended Moulded, Black / Grey020-508-009 Backbox Extension Standard Assembly Black / Grey020-509-009 Backbox Extension Deep Assembly Black / Grey020-576 Main Cover, Stainless Steel020-577 Extension Cover Stainless Steel020-621 Zone Extension Cover, Stainless / Steel020-621-009 256 Zone Extension Cover, Black / Grey020-541-501 PSU7A / 78Ah Battery Enclosure

Modules:020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588 Notifier Dual Loop Interface Board, (LIB)020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 ID²net Fibre Optic Interface Kit020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel

154g/01

Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals

2. Fixed build products incorporate a corresponding Basic Equipment Kit.Mach 2.8 Fixed build 2 loop analogue addressable

control and indicating equipment002-530 2 Loop, PSU3A, Group 0

Incorporating the following as modular units:

Enclosures:020-472-009 Backbox Kit Standard020-473-009 Backbox Kit Extended, Black / Grey020-474-009 Backbox Kit Extended Deep, Black / Grey020-475-009 Backbox Kit Double Extended, Black / Grey020-476-009 Backbox Kit Double Extended Deep, Black / Grey020-480-501 Cover Kit Main Moulded, Black / Grey020-481-009 Cover Kit Extended Moulded, Black / Grey020-508-009 Backbox Extension Standard Assembly Black / Grey020-509-009 Backbox Extension Deep Assembly Black / Grey020-576 Main Cover, Stainless Steel020-577 Extension Cover Stainless Steel020-621 Zone Extension Cover, Stainless / Steel020-621-009 256 Zone Extension Cover, Black / Grey020-541-501 PSU7A / 78Ah Battery Enclosure

Modules:020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module

154g/01

Page 39: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 29

Certificated Products LPCB Ref. No.

020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588 Notifier Dual Loop Interface Board, (LIB)020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 ID²net Fibre Optic Interface Kit020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel

Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals

2. Fixed build products incorporate a corresponding Basic Equipment Kit.Mach 2.8 Fixed build 4 loop analogue addressable

control and indicating equipment020-905 4 Loop, PSU7A, Group 0

Incorporating the following as modular units:

Enclosures:020-472-009 Backbox Kit Standard020-473-009 Backbox Kit Extended, Black / Grey020-474-009 Backbox Kit Extended Deep, Black / Grey020-475-009 Backbox Kit Double Extended, Black / Grey020-476-009 Backbox Kit Double Extended Deep, Black / Grey020-480-501 Cover Kit Main Moulded, Black / Grey020-481-009 Cover Kit Extended Moulded, Black / Grey020-508-009 Backbox Extension Standard Assembly Black / Grey020-509-009 Backbox Extension Deep Assembly Black / Grey020-576 Main Cover, Stainless Steel020-577 Extension Cover Stainless Steel020-621 Zone Extension Cover, Stainless / Steel020-621-009 256 Zone Extension Cover, Black / Grey020-541-501 PSU7A / 78Ah Battery Enclosure

Modules:020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588 Notifier Dual Loop Interface Board, (LIB)020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 ID²net Fibre Optic Interface Kit020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel

154g/01

Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals

2. Fixed build products incorporate a corresponding Basic Equipment Kit.Mach 2.8 Fixed build 6 loop analogue addressable

control and indicating equipment154g/01

Page 40: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

30 31 Dec 2012

Certificated Products LPCB Ref. No.

020-906 6 Loop, PSU7A, Group 0

Incorporating the following as modular units:

Enclosures:020-472-009 Backbox Kit Standard020-473-009 Backbox Kit Extended, Black / Grey020-474-009 Backbox Kit Extended Deep, Black / Grey020-475-009 Backbox Kit Double Extended, Black / Grey020-476-009 Backbox Kit Double Extended Deep, Black / Grey020-480-501 Cover Kit Main Moulded, Black / Grey020-481-009 Cover Kit Extended Moulded, Black / Grey020-508-009 Backbox Extension Standard Assembly Black / Grey020-509-009 Backbox Extension Deep Assembly Black / Grey020-576 Main Cover, Stainless Steel020-577 Extension Cover Stainless Steel020-621 Zone Extension Cover, Stainless / Steel020-621-009 256 Zone Extension Cover, Black / Grey020-541-501 PSU7A / 78Ah Battery Enclosure

Modules:020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588 Notifier Dual Loop Interface Board, (LIB)020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 ID²net Fibre Optic Interface Kit020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel

Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals

2. Fixed build products incorporate a corresponding Basic Equipment Kit.Mach 2.8 Fixed build 8 loop analogue addressable

control and indicating equipment020-907 8 Loop, PSU7A, Group, 78Ah Battery Enclosure

Incorporating the following as modular units:

Enclosures:020-472-009 Backbox Kit Standard020-473-009 Backbox Kit Extended, Black / Grey020-474-009 Backbox Kit Extended Deep, Black / Grey020-475-009 Backbox Kit Double Extended, Black / Grey020-476-009 Backbox Kit Double Extended Deep, Black / Grey020-480-501 Cover Kit Main Moulded, Black / Grey020-481-009 Cover Kit Extended Moulded, Black / Grey020-508-009 Backbox Extension Standard Assembly Black / Grey020-509-009 Backbox Extension Deep Assembly Black / Grey020-576 Main Cover, Stainless Steel020-577 Extension Cover Stainless Steel020-621 Zone Extension Cover, Stainless / Steel020-621-009 256 Zone Extension Cover, Black / Grey020-541-501 PSU7A / 78Ah Battery Enclosure

Modules:020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly

154g/01

Page 41: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 31

Certificated Products LPCB Ref. No.

020-588 Notifier Dual Loop Interface Board, (LIB)020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 ID²net Fibre Optic Interface Kit020-647 ID²net Network Gateway Module, (NGM) for use in Mach 2.8 Panel

Notes: 1. Products are available in language variant as follows: Group 0: English with English manuals

2. Fixed build products incorporate a corresponding Basic Equipment Kit.

Carillion (Novar Systems Ltd)Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United KingdomTel: 0116 246 2000 • Fax: 0116 246 2300Website: www.gent.co.uk

Certificate No: 042bc to EN 54-2: 1997+A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006

Certificated Products LPCB Ref. No.

CP2-AMC Two loop analogue addressable control and indicating equipment(English language)

Incorporating as modular units:

2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-161 Text Membrane (English) 2434-861 Copper network card

Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

042bc/04

CP4-AMC One to Four loop analogue addressable control and indicating equipment (English language)

Incorporating as modular units:

2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-157 Text Membrane (English) 2434-674 Copper network card

Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2:

042bc/07

Page 42: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

32 31 Dec 2012

Certificated Products LPCB Ref. No.

7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

CP4-72-AMC One to Six loop analogue addressable control and indicating equipment (English Language)

Incorporating as modular units:

2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-992 Thermistor board 2434-860 Battery terminal board 2434-832 Power supply PCB 2434-854 Backplane PCB 2434-761 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer module 4374-157 Text Membrane (English) 2434-674 Copper network card

( Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

042bc/11

Channel Safety Systems Ltd9 Petersfield Business Park, Petersfield GU32 3QA, United KingdomTel: 08458847000 • Fax: 08458846000E-mail: [email protected] • Website: www.chanelsafety.co.uk

Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

CFP702-4/CHAN Two zone conventional control and indicating equipment

Incorporating the units:

RPF0702005 Power supply PCBSPF0724851 2 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/07

CFP704-4/CHAN Four zone conventional control and indicating equipment

Incorporating the units:

RPF0702005 Power supply PCBSPF0724853 4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/08

CFP708-4/CHAN Eight zone conventional control and indicating equipment 176b/09

Page 43: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 33

Certificated Products LPCB Ref. No.

Incorporating the units:

RPF0702005 Power supply PCBSPF0724855 8 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

Computionics Limited (Trading as C-Tec)Challenge Way, Martland Mill Industrial Estate, Wigan, Lancashire WN5 OLD, United KingdomTel: +44 (0)1942 322744/42444 • Fax: +44 (0)1942 829867E-mail: [email protected] • Website: www.c-tec.co.uk

Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

XFP502/H 2 loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housingIncorporating the following units:

SPF0706000 Switch mode power supply board SPF0501202 XFP Hochiki 2 loop, main motherboard SPF0501200 Display board "keypad display"

Certified with the following options with requirements from EN 54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

176b/01

Notes:1. Scope of approval does not include the operation of the network functionality.

XFP502/X 2 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housingIncorporating the following units:

SPF0706000 Switch mode power supply board SPF0501201 XFP Apollo 2 loop, main motherboard SPF0501200 Display board "Keypad display"

Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

176b/02

Notes:1. Scope of approval does not include the operation of the network functionality.

XFP501/H 1 Loop, 32 zone analogue addressable control and indicating equipment using Hochiki Protocol, metal housingIncorporating the following units:

SPF0706000 Switch mode power supply board SPF0501212 XFP Hochiki 1 loop, main motherboard

176b/03

Page 44: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

34 31 Dec 2012

Certificated Products LPCB Ref. No.

SPF0501200 Display board "Keypad display"

Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test conditionNotes:1. Scope of approval does not include the operation of the network functionality.

XFP501/X 1 Loop, 32 zone analogue addressable control and indicating equipment using Apollo Protocol, metal housingIncorporating the following units:

SPF0706000 Switch mode power supply board SPF0501211 XFP Apollo 1 loop, main motherboard SPF0501200 Display board "keypad display"

Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

176b/04

Notes:1. Scope of approval does not include the operation of the network functionality.

XFP501E/H 1 Loop, 16 zone analogue addressable control and indicating equipment using Hochiki protocol, plastic housingIncorporating the following units:

SPF0702480 Switch mode power supply board SPF0501102 XFP Hochiki 1 loop, main motherboard

Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

176b/05

Notes:1. Scope of approval does not include the operation of the network functionality

XFP501E/X 1 Loop, 16 zone analogue addressable control and indicating equipment using Apollo Protocol, plastic housingIncorporating the following units:

SPF0702480 Switch mode power supply board SPF0501101 XFP Apollo 1 loop, main motherboard

Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

176b/06

Notes:

Page 45: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 35

Certificated Products LPCB Ref. No.

1. Scope of approval does not include the operation of the network functionalityCFP702-4 Two zone conventional control and indicating equipment

Incorporating the units:

SPF0702480 Switch mode power supply unit boardSPF0724851 2 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/07

CFP704-4 Four zone conventional control and indicating equipment

Incorporating the units:

SPF0702480 Switch mode power supply unit boardSPF0724853 4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/08

CFP708-4 Eight zone conventional control and indicating equipment

Incorporating the units:

SPF0702480 Switch mode power supply unit boardSPF0724855 8 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/09

CFP702-4/ACNL Two zone conventional control and indicating equipment

Incorporating the following units:

SPF0702480 Switch mode power supply unit boardSPF0724837 2 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs7.13 Alarm counter10 Test condition

176b/10

CFP704-4/ACNL Four zone conventional control and indicating equipment

Incorporating the following units:

SPF0702480 Switch mode power supply unit boardSPF0724839 4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs7.13 Alarm counter10 Test condition

176b/11

CFP708-4/ACNL Eight zone conventional control and indicating equipment

Incorporating the following units:

SPF0702480 Switch mode power supply unit boardSPF0724841 8 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

176b/12

Page 46: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

36 31 Dec 2012

Certificated Products LPCB Ref. No.

7.8 Output to fire alarm devices(s)7.11 Delays to outputs7.13 Alarm counter10 Test condition

Certificate No: 176c to EN 12094-1: 2003 and EN 54-2: 1997 + A1: 2006 + A2: 2007, EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

EP203 Conventional three zone class A extinguisher control panel

Incorporating the following units:

SPF0000203 Main extinguisher controlSPF0000212 External relay interfaceSPF0003613 Power supply unitSPF0000214 EP214 terminator

Incorporating as modular units:

EP210S Remote Status Unit Surface Mount optional (See Note 1)EP211 Economy Status Unit optional (See Note 1)

Certified with the following options with requirements from EN 12094-1:20034.17 Delay of extinguishing signal4.18 Signal representing the flow of extinguishing agent4.19 Monitoring of the status of components4.20 Emergency hold device4.21 Control of flooding time4.23 Manual only mode4.26 Triggering of equipment outside the system4.27 Emergency abort device4.30 Activation of alarm devices with different signals

Certified with the following options with requirements from EN-54-2:19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.13 Alarm counter 10 Test condition

176c/01

Notes:1) Optional Remote Status Unit part No. EP210S & Economy Status Unit part No.

EP211 are not certified as meeting the requirements of the standards specified.

2) Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C.

EP203/CON Conventional three zone class A extinguisher control panel under Context Plus Brand

Incorporating the following units:

SPF0000203 Main extinguisher controlSPF0000212 External relay interfaceSPF0003613 Power supply unitSPF0000214 EP214 terminator

Incorporating as modular units:

EP210S Remote Status Unit Surface Mount optional (See Note 1)EP211 Economy Status Unit optional (See Note 1)

Certified with the following options with requirements from EN 12094-1:20034.17 Delay of extinguishing signal4.18 Signal representing the flow of extinguishing agent4.19 Monitoring of the status of components4.20 Emergency hold device4.21 Control of flooding time4.23 Manual only mode

176c/01

Page 47: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 37

Certificated Products LPCB Ref. No.

4.26 Triggering of equipment outside the system4.27 Emergency abort device4.30 Activation of alarm devices with different signals

Certified with the following options with requirements from EN-54-2:19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.13 Alarm counter 10 Test conditionNotes:1) Optional Remote Status Unit part No. EP210S & Economy Status Unit part No.

EP211 are not certified as meeting the requirements of the standards specified.

2) Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C.

EP203/DE Conventional three zone class A extinguisher control panel German Language Variant

Incorporating the following units:

SPF0000203 Main extinguisher controlSPF0000212 External relay interfaceSPF0003613 Power supply unitSPF0000214 EP214 terminator

Incorporating as modular units:

EP210S Remote Status Unit Surface Mount optional (See Note 1)EP211 Economy Status Unit optional (See Note 1)

Certified with the following options with requirements from EN 12094-1:20034.17 Delay of extinguishing signal4.18 Signal representing the flow of extinguishing agent4.19 Monitoring of the status of components4.20 Emergency hold device4.21 Control of flooding time4.23 Manual only mode4.26 Triggering of equipment outside the system4.27 Emergency abort device4.30 Activation of alarm devices with different signals

Certified with the following options with requirements from EN-54-2:19977.8 Output to fire alarm device(s)7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment7.13 Alarm counter 10 Test condition

176c/01

Notes:1) Optional Remote Status Unit part No. EP210S & Economy Status Unit part No.

EP211 are not certified as meeting the requirements of the standards specified.

2) Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C.

Page 48: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

38 31 Dec 2012

Control Equipment LimitedHillcrest Business Park, Dudley, West Midlands DY2 9AP, United KingdomTel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972E-mail: [email protected] • Website: www.controlequipment.com

Certificate No: 018a to BS 5839: Part 4. This certificate is to a withdrawn standard. Control and indicating equipment conformingto this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU.

Control and indicating equipmentCertificated Products LPCB Ref.

No.Precept 2 zone control and indicating equipment

Incorporating as modular unitsC1423 MotherboardC1440 Display Board

018a/01

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Precept 4 zone control and indicating equipmentIncorporating as modular units

C1423 Motherboard C1441 Display Board

018a/02

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Precept 8 zone control and indicating equipmentIncorporating as modular units

C1427 MotherboardC1462 Display Board

018a/03

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Precept 16 zone control and indicating equipmentIncorporating as modular units

C1425 MotherboardC1426 Display Board

018a/04

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Precept 32 zone control and indicating equipmentIncorporating as modular units

C1425 MotherboardC1426 Display BoardC1464 Display Board

018a/05

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Series 600 2 zone control and indicating equipmentIncorporating as modular units

C1423 MotherboardC1440 Display Board

018a/06

Certified with the following options from EN 54 Part 2:

Page 49: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 39

Certificated Products LPCB Ref. No.

7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Series 600 4 zone control and indicating equipmentIncorporating as modular units

C1423 MotherboardC1441 Display Board

018a/07

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Series 600 8 zone control and indicating equipmentIncorporating as modular units

C1427 MotherboardC1462 Display Board

018a/08

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Series 600 16 zone control and indicating equipmentIncorporating as modular units

C1425 MotherboardC1426 Display Board

018a/09

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Series 600 32 zone control and indicating equipmentIncorporating as modular units

C1425 MotherboardC1426 Display BoardC1464 Display Board

018a/10

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Certificate No: 018c to EN 54: Part 2 and 4: 1997Certificate No: 018q-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018s-(cl-1) to EN 54-2:1997 + A1: 2006 and EN 54-4:1997 + A1: 2002 + A2: 2006

Control and indicating equipmentCertificated Products LPCB Ref.

No..

Discovery 4 loop analogue addressable control and indicating equipmentIncorporating:

A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230 Vac power supply control card A1599 Printer board

018c/01

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Precept En2 (2605-100) 2 zone conventional control and indicating equipment 018c/02

Page 50: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

40 31 Dec 2012

Certificated Products LPCB Ref. No.

Incorporating as modular units:- C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Precept En4 (2605-101) 4 zone conventional control and indicating equipmentIncorporating as modular units:-

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/03

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Precept En8 (2605-102) 8 zone conventional control and indicating equipmentIncorporating as modular units:-

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/04

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Precept En16 (2605-103) 16 zone conventional control and indicating equipmentIncorporating as modular units:-

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/05

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Precept En32 (2605-104) 32 zone conventional control and indicating equipmentIncorporating as modular units:-

C1627 Mother board C1629 Display board C1631 Repeater interface board (option) C1632 16 Zone Expansion board C1652 5A Power supply board

018c/06

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Precept En8 (2605-110) 8 zone conventional repeater unitIncorporating as modular units:-

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/R01

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Page 51: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 41

Certificated Products LPCB Ref. No.

Precept En16 Repeater (2605-111)

16 zone conventional repeater unitIncorporating as modular units:-

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/R02

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Precept En32 Repeater (2605-112)

32 zone conventional repeater unitIncorporating as modular units:-

C1627 Mother board C1628 Display board C1631 Repeater interface board (option)

018c/R03

Certified with the following options from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

508.031.701 FIRE CLASS Duo-CEL, 1 zone conventional control and indicating equipment

Incorporating as modular units: C1694 - 2605501, 1 Zone Motherboard BAQ-35T24 Power Supply

018q/01

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A7.13 Alarm counter

10 Test condition508.031.702 FIRE CLASS Duo-CEL, 2 zone conventional control and indicating equipment

Incorporating as modular units: C1694 - 2605502, 2 Zone Motherboard BAQ-35T24 Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

018q/02

508.031.703 FIRE CLASS Duo-CEL, 4 zone conventional control and indicating equipment

Incorporating as modular units: C1694 - 2605503 4 Zone Motherboard BAQ-35T24 Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

018q/03

508.031.704 FIRE CLASS Duo-CEL, 8 zone conventional control and indicating equipment

Incorporating as modular units: C1694 - 2605504, 8 Zone Motherboard BAQ-35T24 Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

018q/04

508.031.705 FIRE CLASS Duo-CEL, Fire alarm repeater (mains). 018q/R01

Page 52: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

42 31 Dec 2012

Certificated Products LPCB Ref. No.

Incorporating as modular units: C1694 2605505, Repeater Motherboard BAQ-35T24 Power Supply

Note: Compatible with 2605543 & 2605544 panels only.508.031.706 FIRE CLASS Duo-CEL, Fire alarm repeater (24 VDC).

Incorporating as a modular unit: C1694 2605506, Repeater Motherboard

018q/R02

Note: Compatible with 2605543 & 2605544 panels only.

557.200.701 FIRE CLASS 32-1 analogue addressable control and indicating equipment1 loop, 32 ZoneIncorporating as modular units:

DCM832R Operator Control / Display Module CPU800 Main CPU module FIM801 Field Interface Module PMM800 Power Supply Monitor BAQ60T24 Power Supply Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

018s/01

Note:1) This product approval does not constitute compliance with

the fire detection and alarm systems requirements of EN 54-13.

557.200.702 MZX253 analogue addressable control and indicating equipment 2 loop, 64 Zone Incorporating as modular units:

DCM864R Operator Control / Display Module CPU800 Main CPU module FIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply

and as optional modular units: IOB800 Input/Output Expansion Board

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A)

7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency)

7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency)

7.13 Alarm counter 8.3 Fault signals from points

8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface

018s/02

Note:

Page 53: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 43

Certificated Products LPCB Ref. No.

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

557.200.703 FIRE CLASS 64-4 analogue addressable control and indicating equipment4 loop, 64 Zone

Incorporating as modular units: DCM864R Operator Control / Display Module CPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply PMM840 Power Supply Monitor XLM800 Loop Expander Board and as optional modular units: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A)

7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency)

7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.12.3 Dependencies on more than one alarm signal (Type C dependency)

7.13 Alarm counter 8.3 Fault signals from points

8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface

018s/03

Note:This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

557.200.704 FIRE CLASS 240-2 analogue addressable control and indicating equipment 2 loop, 240 Zone

Incorporating as modular units: DCM832 Operator Control / Display Module CPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply and as optional modular units: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A)

7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency)

7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)

7.13 Alarm counter 8.3 Fault signals from points

8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface

018s/04

Note:1) This product approval does not constitute

compliance with the fire detection and alarm systems requirements of EN 54-13.

557.200.705 FIRE CLASS 240-4 analogue addressable control and indicating equipment 018s/05

Page 54: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

44 31 Dec 2012

Certificated Products LPCB Ref. No.

4 loop, 240 Zone Incorporating as modular units: DCM832 Operator Control / Display Module CPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply Monitor BAQ140T24 Power Supply PMM840 Power Supply Monitor XLM800 Loop Expander Board and as optional modular units: IOB800 Input/Output Expansion Board Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A)

7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment

7.11 Delays to outputs 7.12.1 Dependencies on more than one alarm signal (Type A dependency)

7.12.2 Dependencies on more than one alarm signal (Type B dependency)

7.12.3 Dependencies on more than one alarm signal (Type C dependency) 7.13 Alarm counter 8.3 Fault signals from points

8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition 11 Standardized input/output interface Note:This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

557.200.706 FIRE CLASS 32 RA, 32 Zone Repeater Panel, is approved for use with the 557.200.701 Fire Class 32-1 control and indicating equipment. Incorporating as modular units:

DCM832R Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply

018s/R01

557.200.707 FIRE CLASS 64 RA, 64 Zone Repeater Panel, is approved for use with the 557.200.702 Fire Class 64-2 and 557.200.703 Fire Class 64-4

control and indicating equipment. Incorporating as modular units:

DCM864R Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply

018s/R02

557.200.708 FIRE CLASS 240 RA, 240 Zone Repeater Panel, is approvedfor use with the 557.200.704 Fire Class 240-2

and 557.200.705 Fire Class 240-4 control and indicating equipment. Incorporating as modular units:

DCM832 Operator Control / Display Module PMM800 Power Supply Monitor BAQ60T24 Power Supply

018s/R03

Certificate No: 018t-(cl-1) to EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018n to EN 54-4: 1997 + A1: 2002 + A2: 2006

Power Supply UnitCertificated Products LPCB Ref.

No.PSU A17 Addressable 17Ah Power Supply Unit 018n/02

Notes:

Page 55: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 45

Certificated Products LPCB Ref. No.

1. The unit is not intended to supply power to Fire Alarm Control Panels2. The maximum lead length for the fault output connection is 3m

PSU A38 Addressable 38Ah Power Supply Unit 018n/03Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels2. The maximum lead length for the fault output connection is 3m

557.200.732 PSU A17 Addressable 17Ah Power Supply Unit 018t/01Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels2. The maximum lead length for the fault output connection is 3m

557.200.733 PSU A38 Addressable 38Ah Power Supply Unit 018t/02Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels2. The maximum lead length for the fault output connection is 3m

557.200.731 FIRE CLASS 1.9A Power Supply Unit 018t/03Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels

Cooper Industries IncWheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United KingdomTel: +44 (0)1302 303303 • Fax: +44 (0)1302 367155E-mail: [email protected] • Website: www.cooper-ls.com

UK Sales:Menvier & JSBTel: +44 (0)1302 303202 • Fax: +44 (0)1302 367155E-mail: [email protected] • Website: www.cooper-ls.com

UK Sales:Tel: +44 (0)1594 541900 • Fax: +44 (0)1594 541910E-mail: [email protected] • Website: www.cooperfire.co.uk

Certificate No: 714a to EN 54 Part 2 and 4 :1997

Certificated Products LPCB Ref. No.

CF3000 Analogue addressable 2 and 4 loop Control and indicating equipmentIncorporating the following units:

ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6 Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface

714a/01

Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment

Page 56: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

46 31 Dec 2012

Certificated Products LPCB Ref. No.

9.5 Disablement of each address point 10 Test condition

DF6000 Analogue addressable 2 and 4 loop control and indicating equipmentIncorporating the following units:

ADF6 Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface

714a/01

Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

FX6000 Analogue addressable 2 and 4 Loop control and indicating equipmentIncorporating the following units:

ADF6 Back Assembled back box YPCB2153 Motherboard PCB YPCB2147 PSU PCB YPCB2148 2 Loop Card (2 off) ADF6Screen Touch Screen YPCB2185 Complete Display + Micro PCB ADF6 DISPCOVER Display PCB Cover ADF6FACIA Front Moulding ADF6PRINTDOOR Printer Door Moulding BAT-NP12-12 Batteries (2 off) ADF6HINGE Door Hinges ADF6OPFACIA Optional Anti Tamper Cover ADF6PRINTER Printer YPCB2187 Fire Brigade Interface

714a/01

Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

CF2000 Analogue addressable 2 Loop control and indicating equipmentIncorporating the following units:

PR202-50-2209 Power supply board PR202-50-2206 Main motherboard PR202-50-2205 Display board

714a/02

Certified with the following options from EN 54 Part 2: 7.8 Output to fire alarm device(s) 7.9 Output to fire alarm routing equipment 7.10 Output to automatic fire protection equipment 7.11 Delays to the actioning of outputs fire alarm devices and fire routing

equipment 7.12 Coincidence detection 7.13 Alarm counter 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

Page 57: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 47

Cooper Lighting and Safety LtdWheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United KingdomTel: 01302 303397 • Fax: 01302 303251Website: www.cooper-Is.com

Certificate No: 714h to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

CF3000 Intelligent analogue addressable 2 and 4 loop control and indicating equipment

Incorporating the following units:

ADF6 Back Assembled back boxYPCB2153 Motherboard PCBYPCB2147 PSU PCBYPCB2148 2 Loop Card (2 off)ADF6Screen Touch ScreenYPCB2185 Complete Display + Micro PCBADF6 DISPCOVER Display PCB CoverADF6FACIA Front MouldingADF6PRINTDOOR Printer Door MouldingBAT-NP12-12 Batteries (2 off)ADF6HINGE Door HingesADF6OPFACIA Optional Anti Tamper CoverADF6PRINTER PrinterYPCB2187 Fire Brigade Interface

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.10.1 Output to automatic fire protection equipment (Type A)7.10.2 Output to automatic fire protection equipment (Type B)7.11 Delays to outputs7.12.3 Dependencies on more than one alarm signal (Type C)7.13 Alarm counter8.9 Output to fault warning routing equipment9.5 Disablement of each address point10 Test condition

Notes: 1. The scope of approval does not include the network functionality.

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

714h/01

DF6000 Intelligent analogue addressable 2 and 4 loop control and indicating equipment

Incorporating the following units:

ADF6 Back Assembled back boxYPCB2153 Motherboard PCBYPCB2147 PSU PCBYPCB2148 2 Loop Card (2 off)ADF6Screen Touch ScreenYPCB2185 Complete Display + Micro PCBADF6 DISPCOVER Display PCB CoverADF6FACIA Front MouldingADF6PRINTDOOR Printer Door MouldingBAT-NP12-12 Batteries (2 off)ADF6HINGE Door HingesADF6OPFACIA Optional Anti Tamper CoverADF6PRINTER PrinterYPCB2187 Fire Brigade Interface

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm device(s)

714h/01

Page 58: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

48 31 Dec 2012

Certificated Products LPCB Ref. No.

7.9.1 Output to fire alarm routing equipment7.10.1 Output to automatic fire protection equipment (Type A)7.10.2 Output to automatic fire protection equipment (Type B)7.11 Delays to outputs7.12.3 Dependencies on more than one alarm signal (Type C)7.13 Alarm counter8.9 Output to fault warning routing equipment9.5 Disablement of each address point10 Test condition

Notes: 1. The scope of approval does not include the network functionality.

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

CF2000 Analogue addressable 2 loop control and indicating equipment

Incorporating the following units:

PR202-50-2209 Power supply boardPR202-50-2206 Main motherboardPR202-50-2205 Display board

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.10.1 Output to automatic fire protection equipment (Type A)7.11 Delays to outputs7.12.3 Dependencies on more than one alarm signal (Type C)7.13 Alarm counter8.9 Output to fault warning routing equipment9.5 Disablement of each address point10 Test condition

Notes: 1. The scope of approval does not include the network functionality.

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

714h/02

Detector Electronics Corporation6901 West 110th Street, Minneapolis, Minesota 55438, USATel: +001 952 946 6488E-mail: [email protected] • Website: www.det-tronics.com

Certificate No: 973c to EN 54-2: 1997 + A1: 2006Certificate No: 973d to EN 54-2: 1997 + A1: 2006 + EN12094-1: 2003

Certificated Products LPCB Ref. No.

EQ5400D Single loop eight zone addressable control and indicating equipment

IQ3150 Controller Main controller Detection panel Detection panelEQ2220 (GFM) Ground Fault MonitorLTM Lon termination moduleEQ3730 (EDIO) Enhanced Discrete Input/Output (SIL only)

and as optional modular units:

EQ3710 (AIM) Analogue Input ModuleEQ3720 (RM) Relay ModuleModel EQ22EM (IDCSC) Initiating Device Circuit - Short Circuit

973c/01

Page 59: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 49

Certificated Products LPCB Ref. No.

Model EQ25EM (SAM) Signal Audible ModuleModel EQ24EM (NE) Network ExtenderModel EQ24EM (PLR) Physical Layer Repeater EQ3810 (PDM) Power Distribution Module750XCXH-24D Magnecraft relay module

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 10 Test condition

EQ5400R Single loop eight zone addressable control and indicating equipment

Incorporating as modular units:

EQ3150 Controller Main controller Detection panel Detection panelRouting panel Routing panelEQ2220 (GFM) Ground Fault MonitorLTM Lon termination moduleEQ3730 (EDIO) Enhanced Discrete Input/Output (SIL only)

and as optional modular units:

EQ3710 (AIM) Analogue Input ModuleEQ3720 (RM) Relay ModuleModel EQ22EM (IDCSC) Initiating Device Circuit - Short CircuitModel EQ25EM (SAM) Signal Audible ModuleModel EQ24EM (NE) Network ExtenderModel EQ24EM (PLR) Physical Layer Repeater EQ3810 (PDM) Power Distribution Module750XCXH-24D Magnecraft relay module

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 10 Test condition

973c/02

EQ5400E Single loop eight zone addressable control and indicating equipment and two extinguishing zone class B electrical automatic control and delay devices

Incorporating as modular units:

EQ3150 Controller Main controller (Redundant)Detection panel Detection panelRouting panel Routing panelExtinguishing panel Extinguishing panelEQ2220 (GFM) Ground Fault MonitorEQ3LTM Lon termination moduleEQ3730 (EDIO) Enhanced Discrete Input/Output (SIL only)

and as optional modular units:

EQ3710 (AIM) Analogue Input ModuleEQ3720 (RM) Relay ModuleModel EQ22EM (IDCSC) Initiating Device Circuit - Short CircuitModel EQ25EM (SAM) Signal Audible ModuleModel EQ24EM (NE) Network ExtenderModel EQ24EM (PLR) Physical Layer Repeater EQ3810 (PDM) Power Distribution Module750XCXH-24D Magnecraft relay module

Certified with the following options with requirements from EN 54 Part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment

973d/01

Page 60: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

50 31 Dec 2012

Certificated Products LPCB Ref. No.

7.9.2 Alarm confirmation input from fire alarm routing equipment 7.10.1 Outputs to fire protection equipment (Type A) 7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.12.2 Dependencies on more than one alarm signal (Type B dependency) 7.13 Alarm counter 8.3 Fault signals from points 8.4 Total loss of the power supply 8.9 Output to fault warning routing equipment 10 Test condition

Certified with the following options with requirements from EN 12094-1:4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device4.21 Control of flooding time 4.23 Manual only mode4.24 Triggering signals to equipment within the system4.26 Triggering of equipment outside the system

EQ5400G Single loop eight zones Addressable control and indicating equipment and two extinguishing zone class B electrical automatic control and delay devices.

Incorporating as modular units:

EQ3150 Controller Main controller (Redundant)Detection panel Detection panelExtinguishing panel Extinguishing panelEQ2220 (GFM) Ground Fault MonitorEQ3LTM Lon termination moduleEQ3730 (EDIO) Enhanced Discrete Input/Output (SIL only)

and as optional modular units:

EQ3710 (AIM) Analogue Input ModuleEQ3720 (RM) Relay ModuleModel EQ22EM (IDCSC) Initiating Device Circuit - Short CircuitModel EQ25EM (SAM) Signal Audible ModuleModel EQ24EM (NE) Network ExtenderModel EQ24EM (PLR) Physical Layer Repeater EQ3810 (PDM) Power Distribution Module750XCXH-24D Magnecraft relay module

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices 7.10.1 Outputs to fire protection equipment (Type A)

7.10.2 Outputs to fire protection equipment (Type B) 7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.12.2 Dependencies on more than one alarm signal (Type B dependency)

7.13 Alarm counter 8.3 Fault signals from points

8.4 Total loss of the power supply 10 Test condition

Certified with the following options with requirements from EN 12094-1:

4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.24 Triggering signals to equipment within the system 4.26 Triggering of equipment outside the system

973d/02

Page 61: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 51

Certificated Products LPCB Ref. No.

Fike Safety Technology LtdUnit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United KingdomTel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk

Certificate No: 331q to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

507-0001 Quadnet, 4 loop analogue addressable control and indicating equipment

Incorporating the following units:10-0049 Main CIE Board10-0050 LED BoardSP14Q006-T LCD Module10-0051 Backplane10-0058 Loop Card10-0053 PSU Interface

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm devices7.10.1 Output to fire protection equipment - Type A7.11 Delays to outputs7.12.2 Dependencies on more than one alarm signal - Type B8.3 Fault signals from points8.9 Fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

331q/01

Note:1. This product approval does not constitute compliance with the fire detection and

alarm systems requirements of EN 54-13

507-0009 Quadnet, 4 loop analogue addressable control and indicating equipment with printer

Incorporating the following units:10-0049 Main CIE Board10-0050 LED BoardSP14Q006-T LCD Module10-0051 Backplane10-0058 Loop Card10-0053 PSU Interface21-0005 Printer

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm devices7.10.1 Output to fire protection equipment - Type A7.11 Delays to outputs7.12.2 Dependencies on more than one alarm signal - Type B8.3 Fault signals from points8.9 Fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

331q/02

Note:1. This product approval does not constitute compliance with the fire detection and

alarm systems requirements of EN 54-13

510-0001 Duonet, 2 loop analogue addressable control and indicating equipment

Incorporating the following units:10-0049 Main CIE Board10-0050 LED Board

331q/04

Page 62: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

52 31 Dec 2012

Certificated Products LPCB Ref. No.

SP14Q006-T LCD Module10-0069 Backplane10-0058 Loop Card10-0053 PSU Interface

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm devices7.10.1 Output to fire protection equipment - Type A7.11 Delays to outputs7.12.2 Dependencies on more than one alarm signal - Type B8.3 Fault signals from points8.9 Fault warning routing equipment9.5 Disablement of each addressable point10 Test conditionNote:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13

510-0003 Duonet, 2 loop analogue addressable control and indicating equipment with printer

Incorporating the following units:10-0049 Main CIE Board10-0050 LED BoardSP14Q006-T LCD Module10-0069 Backplane10-0058 Loop Card10-0053 PSU Interface21-0005 Printer

Certified with the following options with requirements from EN54-2:

7.8 Output to fire alarm devices7.10.1 Output to fire protection equipment - Type A7.11 Delays to outputs7.12.2 Dependencies on more than one alarm signal - Type B8.3 Fault signals from points8.9 Fault warning routing equipment9.5 Disablement of each addressable point10 Test condition

331q/05

Note:1. This product approval does not constitute compliance with the fire detection and

alarm systems requirements of EN 54-13

505-0002 TWINFLEXpro, 2 Zone conventional control and indicating equipment

Incorporating:10-0067 Main Processor Card.

Certified with the following options from EN 54 Part 2:

7.8 Output to fire alarm devices7.10.1 Output type A to fire protection equipment7.11 Delays to outputs7.12.1 Type A dependency on more than one alarm signal8.3 Fault signals from points10 Test condition.

331q/06

505-0004 TWINFLEXpro, 4 Zone conventional control and indicating equipment

Incorporating:10-0067 Main Processor Card.

Certified with the following options from EN 54 Part 2:

7.8 Output to fire alarm devices7.10.1 Output type A to fire protection equipment7.11 Delays to outputs7.12.1 Type A dependency on more than one alarm signal8.3 Fault signals from points10 Test condition.

331q/07

505-0008 TWINFLEXpro, 8 Zone conventional control and indicating equipment 331q/08

Page 63: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 53

Certificated Products LPCB Ref. No.

Incorporating:10-0067 Main Processor Card10-0087 4 Zone expansion card.

Certified with the following options from EN 54 Part 2:

7.8 Output to fire alarm devices7.10.1 Output type A to fire protection equipment7.11 Delays to outputs7.12.1 Type A dependency on more than one alarm signal8.3 Fault signals from points10 Test condition.

Firelite by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 1444 230 300 • Fax: +44 1444 230 888E-mail: [email protected]

Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

FLS2-8 2 Zone 002-475-122 Language region 1, light grey002-489-122 Language region 1, light grey, English manual002-475-222 Language region 2, light grey002-489-222 Language region 2, light grey, English manual

154g/06

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment10 Test condition

FLS2-8 4 Zone 002-475-142 Language region 1, light grey002-489-142 Language region 1, light grey, English manual002-475-242 Language region 2, light grey002-489-242 Language region 2, light grey, English manual

154g/07

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment10 Test condition

FLS2-8 8 Zone 002-475-182 Language region 1, light grey002-489-182 Language region 1, light grey, English manual002-475-282 Language region 2, light grey002-489-282 Language region 2, light grey, English manual

Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit

154g/08

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment

Page 64: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

54 31 Dec 2012

Certificated Products LPCB Ref. No.

7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment10 Test condition

Firesafe10 Sanderson's Way, Marton, Blackpool FY4 4NB, United KingdomTel: 01253 699500 • Fax: 01253 699550E-mail: [email protected] • Website: www.firesafe.co.uk

Certificate No: 176b-(cl-1) to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006

Certificated Products LPCB Ref. No.

FXP502/X Two Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing

Incorporating the following units:

SPF0706000 Switch Mode Power supply boardSPF0501201 XFP Apollo 2 Loop, Main motherboardSPF0501200 Display board Keypad Display

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

176b/02

Notes: 1. Scope of approval does not include the operation of the network functionality.

FXP501/X One Loop, 32 Zone Analogue addressable control and indicating equipment using Apollo Protocol, Metal housing

Incorporating the following units:

SPF0706000 Switch Mode Power supply boardSPF0501211 XFP Apollo 1 Loop, Main motherboardSPF0501200 Display board Keypad Display

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

176b/04

Notes:1. Scope of approval does not include the operation of the network functionality.

FXP501E/X One Loop, 16 Zone Analogue addressable control and indicating equipment using Apollo protocol, Plastic housing

176b/06

Page 65: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 55

Certificated Products LPCB Ref. No.

Incorporating the following units:

SPF0702480 Switch Mode Power supply boardSPF0501101 XFP Apollo 1 Loop, Main motherboard

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment7.12.1 Dependencies on more than one alarm signal Type A 7.12.2 Dependencies on more than one alarm signal Type B7.12.3 Dependencies on more than one alarm signal Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test conditionNotes: 1. Scope of approval does not include the operation of the network functionality.

FCFP2N Two zone conventional control and indicating equipment

Incorporating the units:

SPF0702480 Switch mode power supply unit boardSPF0724851 2 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/07

FCFP4N Four zone conventional control and indicating equipment

Incorporating the units:

SPF0702480 Switch mode power supply unit boardSPF0724853 4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/08

FCFP8N Eight zone conventional control and indicating equipment

Incorporating the units:

SPF0702480 Switch mode power supply unit boardSPF0724855 8 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/09

FIREX Protection System Technology Ltd28-38 Desborough Street, High Wycombe, Bucks, United KingdomTel: +44 (0)1494 601077 • Fax: +44 (0)1494 601011E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 548j to EN 54-2: 1997 and EN54-4: 1997

Page 66: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

56 31 Dec 2012

Certificated Products LPCB Ref. No.

FX200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipmentIncorporating the following units:

F7.820.826 Main board F7.908.312 Zone indication board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power Supply unit F2.910.093 Mains filter R150 Transformer CGM12864 Alphanumeric Display F2.828.630a Printer board (option)

Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration

548j/01

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10 Output to automatic Fire Protection Equipment7.11 Delays to outputs7.12 Coincidence detection8.3 Fault signals from points9.5 Disablement of addressable points

FX1 Single zone conventional control and indicating equipment 548j/02Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

FX2 Two zone conventional control and indicating equipment 548j/03Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

FX4 Four zone conventional control and indicating equipment 548j/04Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

FX8 Eight zone conventional control and indicating equipment 548j/05Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

FX16 Sixteen zone conventional control and indicating equipment 548j/06Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

Gent By Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300E-mail: [email protected] • Website: www.gent.co.uk

Middle East Sales EnquiriesE-mail: [email protected]

Certificate No: 042x to EN 54: Parts 2 & 4: 1997Certificate No: 042bb to EN 54-2: 1997 and EN 54-4: 1997Certificate No: 042bm to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006 and EN 54-16: 2008Certificate No: 042bc to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

AS-2000 Two loop analogue addressable control and indicating equipmentIncorporating as modular units:2434-824 Power supply2434-710 Loop Processor Card

042bb/01

Page 67: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 57

Certificated Products LPCB Ref. No.

2434-833 Master Control Card2434-825 Optical Network Card*2434-821 Message Store Card*2434-822 Mother board2434-835 H.M.I2434-840 Cold fire card2434-796 Addressable speaker card (Optional Card)*2434-826 Addressable daughter speaker card (Optional Card)*2434-780 Audio Input Card (Optional Card)*2434-781 Audio Output Card (Optional Card)* Scope of approval does not include the functionality of the network card and optional voice alarm system cards. Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

Nano-24 Single loop analogue addressable control and indicating equipmentIncorporating as modular units:2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface)

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points10 Test condition

042bc/01

Nano-24-SP Single loop analogue addressable control and indicating equipment (Spanish Language Variant)Incorporating as modular units:2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface)

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points10 Test condition

042bc/02

Nano-24-PO Single loop analogue addressable control and indicating equipment (Portuguese Language Variant)Incorporating as modular units:2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface)

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points10 Test condition

042bc/03

Vigilon Compact-24-N Two loop analogue addressable control and indicating equipment(English language)Incorporating as modular units:2434-859 Master Controller Board (MCB)2434-862 Power Supply Unit2434-762 Display and Key card (DKC)2434-669 Loop processor card4374-161 Text Membrane (English)2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

042bc/04

Vigilon Compact-24-PO Two loop analogue addressable control and indicating equipment(Portuguese language variant)

042bc/05

Page 68: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

58 31 Dec 2012

Certificated Products LPCB Ref. No.

Incorporating as modular units:2434-859 Master Controller Board (MCB)2434-862 Power Supply Unit2434-762 Display and Key card (DKC)2434-669 Loop processor card4374-163 Text Membrane (Portuguese)2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs

Vigilon Compact-24-SP Two loop analogue addressable control and indicating equipment(Spanish language variant)Incorporating as modular units:2434-859 Master Controller Board (MCB)2434-862 Power Supply Unit2434-762 Display and Key card (DKC)2434-669 Loop processor card4374-162 Text Membrane (Spanish)2434-861 Copper network card (Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

042bc/06

Vigilon VIG1-24 One to Four loop analogue addressable control and indicating equipment (English language)Incorporating as modular units:2434-863 Master controller card (M.C.C)2434-710 Loop card2434-831 Power supply PCB2434-854 Backplane PCB2434-861 Display and Key card (D.K.C)2434-864 Terminal card2434-565 Printer Module 4374-157 Text Membrane (English)2434-674 Copper network card(Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

042bc/07

Vigilon VIG1-24-NP One to Four loop analogue addressable control and indicating equipment (English language variant without printer module)Incorporating as modular units:2434-863 Master controller card (M.C.C)2434-710 Loop card2434-831 Power supply PCB2434-854 Backplane PCB2434-861 Display and Key card (D.K.C)2434-864 Terminal card4374-157 Text Membrane (English)2434-674 Copper network card(Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

042bc/08

Vigilon VIG1-24-PO One to Four loop analogue addressable control and indicating equipment(Portuguese language variant without printer module)Incorporating as modular units:2434-863 Master controller card (M.C.C)

042bc/09

Page 69: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 59

Certificated Products LPCB Ref. No.

2434-710 Loop card2434-831 Power supply PCB2434-854 Backplane PCB2434-861 Display and Key card (D.K.C)2434-864 Terminal card4374-159 Text Membrane (Portuguese)2434-674 Copper network card(Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

Vigilon VIG1-24-SP One to Four loop analogue addressable control and indicating equipment (Spanish language variant without printer module)Incorporating as modular units:2434-863 Master controller card (M.C.C)2434-710 Loop card2434-831 Power supply PCB2434-854 Backplane PCB2434-861 Display and Key card (D.K.C)2434-864 Terminal card2434-565 Printer Module 4374-158 Text Membrane (Spanish)2434-674 Copper network card(Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

042bc/10

Vigilon VIG1-72 One to Six loop analogue addressable control and indicating equipment (English Language)Incorporating as modular units:2434-863 Master controller card (M.C.C)2434-710 Loop card2434-992 Thermistor board2434-860 Battery terminal board2434-832 Power supply PCB2434-854 Backplane PCB2434-761 Display and Key card (D.K.C)2434-864 Terminal card2434-565 Printer module 4374-157 Text Membrane (English)2434-674 Copper network card(Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

042bc/11

Vigilon VIG1-72-PO One to Six loop analogue addressable control and indicating equipment(Portuguese Language Variant without printer module)Incorporating as modular units:2434-863 Master controller card (M.C.C)2434-710 Loop card2434-992 Thermistor board2434-860 Battery terminal board2434-832 Power supply PCB2434-854 Backplane PCB2434-761 Display and Key card (D.K.C)2434-864 Terminal card2434-565 Printer module 4374-159 Text Membrane (Portuguese)2434-674 Copper network card(Note: Scope of approval does not include the operation of the network card)

042bc/12

Page 70: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

60 31 Dec 2012

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

Vigilon VIG1-72-SP One to Six loop analogue addressable control and indicating equipment (Spanish Language Variant without printer module)Incorporating as modular units:2434-863 Master controller card (M.C.C)2434-710 Loop card2434-992 Thermistor board2434-860 Battery terminal board2434-832 Power supply PCB2434-854 Backplane PCB2434-761 Display and Key card (D.K.C)2434-864 Terminal card2434-565 Printer module4374-158 Text Membrane (Spanish)2434-674 Copper network card(Note: Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

042bc/13

Compact VA Two loop voice alarm CIE with distributed mains powered amplifier

Incorporating as modular units within the Compact-VA:2434-669LUGI Compact Loop Card2434-859LUGI Compact Network Control Card2434-862LUGI Compact Network PSU Card2434-870LUGI Multiformat DKC Compact VA2434-792 Audio Control Card 2434-023 MPEG Speech Card2434-722 ACU DKC Card

Incorporating as modular units within the Distributed Amplifier Unit:2434-897LUGI Mains powered DAU PSU Card2434-875 Mains Powered DAU Control Card2434-876 Mains Powered DAU Amplifier2434-880 MPEG Speech Card

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

Certified with the following options with requirements from EN 54-16:7.3 Audible warning7.6.2 Manual silencing of the voice alarm condition7.7.2 Manual reset of the voice alarm condition7.8 Output to fire alarm devices8.3 Indication of faults related to the transmission path to the CIE8.4 Indication of faults related to voice alarm zones12.0 Emergency microphones13.14 Redundant power amplifiers

042bm/01

Notes:1. This product approval does not constitute compliance with the fire detection and

alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality.

13270-01 1 zone conventional control and indicating equipment 042x/01Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

Page 71: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 61

Certificated Products LPCB Ref. No.

Xenex 1 13270-01LB 1 zone conventional control and indicating equipment(Xenex brand)

042x/01

Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

13270-02 2 zone conventional control and indicating equipment 042x/02Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

Xenex 2 13270-02LB 2 zone conventional control and indicating equipment (Xenex brand)

042x/02

Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

13270-04 4 zone conventional control and indicating equipment 042x/03Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

Xenex 4 13270-04LB 4 zone conventional control and indicating equipmentbrand)

042x/03

Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

13270-08 8 zone conventional control and indicating equipment 042x/04Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

Xenex 8 13270-08LB 8 zone conventional control and indicating equipment(Xenex brand)

042x/04

Certified with the following options from EN 54 Part 2: 19977.8 Output to fire alarm devices7.11 Delays of actioning to outputs to fire alarm routing equipment10 Test condition

Global System Technology PlcLion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United KingdomTel: +44 (0)1283 225 478 • Fax: +44 (0)1283 222 039E-mail: [email protected] • Website: www.gst.uk.com

Certificate No: 548j to EN 54: Parts 2 and 4 :1997

Certificated Products LPCB Ref. No.

GST 200 Intelligent 1 loop, 30 zone analogue addressable control and indicating equipment

Incorporating the following units:F7.820.826 Main boardF7.820.827 Switch boardF7.820.828 Loop interface boardF7.820.829 Power supply unitF7.908.312 Zone indication boardCGM12864 Alphanumeric displayF2.910.093 Mains filterR150 TransformerF2.828.630a Printer board (option)

Incorporating as optional modular units:F7.820.170 RS-232 board for configurationP-9901 Printer module kit

548j/01

Page 72: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

62 31 Dec 2012

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10 Output to automatic Fire Protection Equipment7.11 Delays to outputs7.12 Coincidence detection8.3 Fault signals from points9.5 Disablement of addressable points

GST 101 Single zone conventional control and indicating equipment 548j/02Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

GST 102 Two zone conventional control and indicating equipment 548j/03Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

GST 104 Four zone conventional control and indicating equipment 548j/04Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

GST 108 Eight zone conventional control and indicating equipment 548j/05Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

GST 116 Sixteen zone conventional control and indicating equipment 548j/06Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

Certificate No: 548p-(cl-1) to EN 54-2: 1997 + A1:2006 and EN 54-4: 1997 + A1:2002 + A2:2006

Certificated Products LPCB Ref. No.

GST200-2 Intelligent 2 loop, 30 zone analogue addressablecontrol and indicating equipment

Incorporating the following units:F7.820.826 Main boardF7.820.827 Switch boardF7.820.828 Loop interface boardF7.820.829b Power supply unitF7.908.312d Zone indication and intervention boardF7.820.1125 Loop board

Incorporating as optional modular units:F7.820.170 RS-232 board for configurationP-9901 Printer module kit

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10.1 Output to automatic Fire Protection Equipment Type A7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points

548p/01

GST-IFP8 Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment

Incorporating the following units:F7.820.1238 Indication boardF7.820.1239 Loop boardF7.820.1311 Power boardF7.820.1312 ZCP boardF7.820.1326 Keypad boardF7.820.1237 Main boardF7.820.1310 Mother board

Incorporating as optional modular units:F7.820.1313 USB communication board

548p/02

Page 73: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 63

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.9.2 Alarm confirmation input from fire routing equipment7.10.1 Output type A7.10.2 Output type B7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

GST102A 2 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.399 MembraneF2.908.1719 Control board with integrated PSEF2.908.1722 Display board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

548p/03

GST104A 4 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.400 MembraneF2.908.1718 Control board with integrated PSEF2.908.1721 Display board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

548p/04

GST108A 8 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.401 MembraneF2.908.1675 Control board with integrated PSEF2.908.1720 Display board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

548p/05

GST116A 16 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.402 MembraneF2.908.1724 Control board with integrated PSEF2.908.1676 Display boardF7.820.1677 Expansion board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

548p/06

Page 74: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

64 31 Dec 2012

Group 4 Securicor PlcManor Royal, The Manor, Crawley, West Sussex RH10 9UN, United KingdomTel: +44 (0)20 87707000 • Fax: +44 (0)20 87722531Website: www.g4s.com

Certificate No: 548j-(cl-1) to EN 54-2: 1997 and EN54-4: 1997Certificate No: 548p-(cl-4) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

GS200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment

Incorporating the following units: F7.820.826 Main board F7.908.312 Zone indication board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829 Power Supply unit F2.910.093 Mains filter R150 Transformer CGM12864 Alphanumeric Display F2.828.630a Printer board (option)

Incorporating as optional modular units: P-9901 Printer module kit F7.820.170 RS232 board for configuration

548j/01

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10 Output to automatic Fire Protection Equipment7.11 Delays to outputs7.12 Coincidence detection8.3 Fault signals from points9.5 Disablement of addressable points

GS101 Single zone conventional control and indicating equipment 548j/02Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

GS102 Two zone conventional control and indicating equipment 548j/03Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

GS104 Four zone conventional control and indicating equipment 548j/04Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

GS108 Eight zone conventional control and indicating equipment 548j/05Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

GS116 Sixteen zone conventional control and indicating equipment 548j/06Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

GS200-2 Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment

Incorporating the following units: F7.820.826 Main board F7.820.827 Switch board F7.820.828 Loop interface board F7.820.829b Power supply unit F7.908.312d Zone indication and intervention board F7.820.1125 Loop board

Incorporating as optional modular units: F7.820.170 RS-232 board for configuration P-9901 Printer module kit

548p/01

Page 75: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 65

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10.1 Output to automatic Fire Protection Equipment Type A7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points

GSIFP8 Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment

Incorporating the following units:F7.820.1238 Indication board F7.820.1239 Loop board F7.820.1311 Power board F7.820.1312 ZCP board F7.820.1326 Keypad board F7.820.1237 Main board F7.820.1310 Mother board

Incorporating as optional modular units:F7.820.1313 USB communication board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.9.2 Alarm confirmation input from fire routing equipment7.10.1 Output type A7.10.2 Output type B7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

548p/02

Gulf Security Technology Co., Ltd.No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, ChinaTel: +86 0335 8502434 • Fax: +86 0335 8502532E-mail: [email protected] • Website: www.gst.com.cn

Sales Beijing:Tel: +86 (10) 6439 1866 • Fax: +86 (10) 6439 1787

Sales Hong Kong:Tel: +852 2877 8566 • Fax: +852 2511 8699

Certificate No: 548j to EN 54-2:1997, EN 54-4:1997 + A1: 2002

Control and indicating equipmentCertificated Products LPCB Ref.

No.GST-200 Intelligent 1 loop, 30 zone, analogue addressable control and indicating equipment

Incorporating the following units: F7.820.826 Main boardF7.908.312 Zone indication boardF7.820.827 Switch boardF7.820.828 Loop interface boardF7.820.829 Power Supply unitF2.910.093 Mains filter

548j/01

Page 76: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

66 31 Dec 2012

Certificated Products LPCB Ref. No.

R150 TransformerCGM12864 Alphanumeric DisplayF2.828.630a Printer board (option)

Incorporating as optional modular units:P-9901 Printer module kitF7.820.170 RS232 board for configurationCertified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10 Output to automatic Fire Protection Equipment7.11 Delays to outputs7.12 Coincidence detection8.3 Fault signals from points9.5 Disablement of addressable points

GST 101 Single zone conventional control and indicating equipment 548j/02Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

GST 102 Two zone conventional control and indicating equipment 548j/03Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

GST 104 Four zone conventional control and indicating equipment 548j/04Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

GST 108 Eight zone conventional control and indicating equipment 548j/08Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

GST 116 Sixteen zone conventional control and indicating equipment 548j/09Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

Certificate No: 548p to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

GST200-2 Intelligent 2 loop, 30 zone analogue addressablecontrol and indicating equipment

Incorporating the following units:F7.820.826 Main boardF7.820.827 Switch boardF7.820.828 Loop interface boardF7.820.829b Power supply unitF7.908.312d Zone indication and intervention boardF7.820.1125 Loop board

Incorporating as optional modular units:F7.820.170 RS-232 board for configurationP-9901A Printer module kit

Optional language variants:10104672 Portuguese language variant10104674 Hungarian language variant

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10.1 Output to automatic Fire Protection Equipment Type A7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points

548p/01

GST-IFP8 Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment

548p/02

Page 77: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 67

Certificated Products LPCB Ref. No.

Incorporating the following units:F7.820.1238 Indication boardF7.820.1239 Loop boardF7.820.1311 Power boardF7.820.1312 ZCP boardF7.820.1326 Keypad boardF7.820.1237 Main boardF7.820.1310 Mother board

Incorporating as optional modular units:F7.820.1313 USB communication board

Optional language variants:10104673 Portuguese language variant10104675 Hungarian language variant

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.9.2 Alarm confirmation input from fire routing equipment7.10.1 Output type A7.10.2 Output type B7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal - Type A7.12.2 Dependencies on more than one alarm signal - Type B7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

GST102A 2 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.399 MembraneF2.908.1719 Control board with integrated PSEF2.908.1722 Display board

Optional modules:10104648 Traditional Chinese text variantF7.843.421 Membrane

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

548p/03

GST104A 4 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.400 MembraneF2.908.1718 Control board with integrated PSEF2.908.1721 Display board

Optional modules:10104649 Traditional Chinese text variantF7.843.422 Membrane

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

548p/04

GST108A 8 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.401 MembraneF2.908.1675 Control board with integrated PSEF2.908.1720 Display board

Optional modules:10104650 Traditional Chinese text variantF7.843.423 Membrane

548p/05

Page 78: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

68 31 Dec 2012

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

GST116A 16 Zone conventional control and indicating equipment

Incorporating the following modules:F7.843.402 MembraneF2.908.1724 Control board with integrated PSEF2.908.1676 Display boardF7.820.1677 Expansion board

Optional modules:10104651 Traditional Chinese text variantF7.843.424 Membrane

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.11 Delays to outputs10 Test condition

548p/06

Haes Systems LimitedColumbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, Middlesex UB8 2JP, United KingdomTel: +44 (0)1895 422066 • Fax: +44 (0)1895 420603E-mail: [email protected] • Website: www.haes-systems.co.uk

Certificate No: 810a to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

FBUS X-Y-Z 1 to 4 Loop analogue addressable and/or 4-20 Zone conventionalcontrol and indicating equipment

Incorporating as modular units: FSB17 Main Display PCB FSB10 Expander PCB PSUFUSION-3A 3A Power Supply Control PCB PSULS100-36 36V 100W Lambda Power supply Module Cabinet size 340H x 460W x 120D mm

and as optional modules:FSB18 4 Way Conventional zone PCBFSB11 1 Loop Card Apollo protocolFSB10-E Bank Extender PCBFSB12-32 16 Way expansion LED PCBFSB12-64 48 Way expansion LED PCB

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs9.5 Disablement of each addressable point10 Test condition

810a/01

Notes:

1. Model name suffix X denote the LED display module type, Y denote the number of conventional zones and Z denote the number of loops.

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

FBUL X-Y-Z 1 to 8 Loop analogue addressable and/or 4-64 zone conventionalcontrol and indicating equipment

Incorporating as modular units: FSB17 Main Display PCB

810a/02

Page 79: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 69

Certificated Products LPCB Ref. No.

FSB10 Expander PCB PSUFUSION-5A 5A Power Supply Control PCB PSULS150-36 36V 150W Lambda Power supply Module Cabinet size 750H x 470W x 140D mm

and as optional modules:FSB18 4 Way Conventional zone PCBFSB11 1 Loop Card Apollo protocolFSB10-E Bank Extender PCBFSB12-32 16 Way expansion LED PCBFSB12-64 48 Way expansion LED PCB

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs9.5 Disablement of each addressable point10 Test conditionNotes:

1. Model name suffix X denote the LED display module type, Y denote the number of conventional zones and Z denote the number of loops.

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

Note:

1. Model name suffix X denote the LED display module type, Y denote the number of conventional zones and Z denote the number of loops.

2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

Honeywell Control Systems LtdHoneywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United KingdomTel: 01344 655609 • Fax: 01344 655474Website: www.honeywellbuildingsolutions.co.uk

Certificate No: 154g-(cl-1) to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

XLS80e Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment.020-538-101 XLS80e Basic Equipment Kit, Group 1020-538-103 XLS80e Basic Equipment Kit, Group 3020-538-104 XLS80e Basic Equipment Kit, Group 4020-538-105 XLS80e Basic Equipment Kit, Group 5

Incorporating the following as modular units:Enclosures:020-040-002 Cover Kit Extended Moulded, Light / Grey020-472-002 Backbox Kit Standard, Light Grey020-473-002 Backbox Kit Extended, Light Grey020-474-002 Backbox Kit Extended Deep, Light Grey020-475-002 Backbox Kit Double Extended, Light Grey020-476-002 Backbox Kit Double Extended Deep, Light Grey020-480-102 Main Cover Kit, Light / Grey020-481-002 Extension Cover Kit, Light / Grey020-509-002 Backbox Extension Deep Assembly Light / Grey020-621-002 256 Zone Extension Cover, Light / Grey020-541-102 PSU7A / 78Ah Battery EnclosureModules:020-708-100 Extension Chassis with Printer Kit020-644-009 Printer Assembly020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612-100 Double Extended Chassis Kit 256 Zone

154g/01

Page 80: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

70 31 Dec 2012

Certificated Products LPCB Ref. No.

020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588-100 Honeywell Dual Loop Interface Board, (LIB)020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB) 020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 XLS80e-NI Fibre Optic Interface Kit020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel

Certified with the following options with requirements:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.3 Output to fire protection equipment type C7.10.4 Fault monitoring of fire protection equipment7.11 Delays to outputs7.12.2 Dependency on more than one alarm signal type B7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablements of addressable points10 Test conditionNote 1: Products are available in language variants as follows:

Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic

Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.XLS80e-2L Fixed build 2 loop analogue addressable control and indicating equipment.

020-692 XLS80e-2L-1, 2 Loop, PSU3A, Group 1020-692-103 XLS80e-2L-3, 2 Loop, PSU3A, Group 3020-692-104 XLS80e-2L-4, 2 Loop, PSU3A, Group 4020-692-105 XLS80e-2L-5, 2 Loop, PSU3A, Group 5

Incorporating the following as modular units:Enclosures:020-040-002 Cover Kit Extended Moulded, Light / Grey020-472-002 Backbox Kit Standard, Light Grey020-473-002 Backbox Kit Extended, Light Grey020-474-002 Backbox Kit Extended Deep, Light Grey020-475-002 Backbox Kit Double Extended, Light Grey020-476-002 Backbox Kit Double Extended Deep, Light Grey020-480-102 Main Cover Kit, Light / Grey020-481-002 Extension Cover Kit, Light / Grey020-509-002 Backbox Extension Deep Assembly Light / Grey020-621-002 256 Zone Extension Cover, Light / Grey020-541-102 PSU7A / 78Ah Battery EnclosureModules:020-708-100 Extension Chassis with Printer Kit020-644-009 Printer Assembly020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612-100 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588-100 Honeywell Dual Loop Interface Board, (LIB)020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU

154g/01

Page 81: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 71

Certificated Products LPCB Ref. No.

Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 XLS80e-NI Fibre Optic Interface Kit020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel

Certified with the following options with requirements:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.3 Output to fire protection equipment type C7.10.4 Fault monitoring of fire protection equipment7.11 Delays to outputs7.12.2 Dependency on more than one alarm signal type B7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablements of addressable points10 Test conditionNote 1: Products are available in language variants as follows:

Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic

Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.XLS80e-4L Fixed build 4 loop analogue addressable control and indicating equipment.

020-693 XLS80e-4L-1, 4 Loop, PSU3A, Group 1020-693-103 XLS80e-4L-3, 4 Loop, PSU3A, Group 3020-693-104 XLS80e-4L-4, 4 Loop, PSU3A, Group 4020-693-105 XLS80e-4L-5, 4 Loop, PSU3A, Group 5

Incorporating the following as modular units:Enclosures:020-040-002 Cover Kit Extended Moulded, Light / Grey020-472-002 Backbox Kit Standard, Light Grey020-473-002 Backbox Kit Extended, Light Grey020-474-002 Backbox Kit Extended Deep, Light Grey020-475-002 Backbox Kit Double Extended, Light Grey020-476-002 Backbox Kit Double Extended Deep, Light Grey020-480-102 Main Cover Kit, Light / Grey020-481-002 Extension Cover Kit, Light / Grey020-509-002 Backbox Extension Deep Assembly Light / Grey020-621-002 256 Zone Extension Cover, Light / Grey020-541-102 PSU7A / 78Ah Battery EnclosureModules:020-708-100 Extension Chassis with Printer Kit020-644-009 Printer Assembly020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612-100 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588-100 Honeywell Dual Loop Interface Board, (LIB)020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 XLS80e-NI Fibre Optic Interface Kit020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80ePanel

154g/01

Page 82: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

72 31 Dec 2012

Certificated Products LPCB Ref. No.

Certified with the following options with requirements:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.3 Output to fire protection equipment type C7.10.4 Fault monitoring of fire protection equipment7.11 Delays to outputs7.12.2 Dependency on more than one alarm signal type B7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablements of addressable points10 Test conditionNote 1: Products are available in language variants as follows:

Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic

Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.XLS80e-6L Fixed build 6 loop analogue addressable control and indicating equipment.

020-694 XLS80e-6L-1, 6 Loop, PSU7A, Group 1020-694-103 XLS80e-6L-3, 6 Loop, PSU7A, Group 3020-694-104 XLS80e-6L-4, 6 Loop, PSU7A, Group 4020-694-105 XLS80e-6L-5, 6 Loop, PSU7A, Group 5

Incorporating the following as modular units:Enclosures:020-040-002 Cover Kit Extended Moulded, Light / Grey020-472-002 Backbox Kit Standard, Light Grey020-473-002 Backbox Kit Extended, Light Grey020-474-002 Backbox Kit Extended Deep, Light Grey020-475-002 Backbox Kit Double Extended, Light Grey020-476-002 Backbox Kit Double Extended Deep, Light Grey020-480-102 Main Cover Kit, Light / Grey020-481-002 Extension Cover Kit, Light / Grey020-509-002 Backbox Extension Deep Assembly Light / Grey020-621-002 256 Zone Extension Cover, Light / Grey020-541-102 PSU7A / 78Ah Battery EnclosureModules:020-708-100 Extension Chassis with Printer Kit020-644-009 Printer Assembly020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612-100 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588-100 Honeywell Dual Loop Interface Board, (LIB)020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 XLS80e-NI Fibre Optic Interface Kit020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel

Certified with the following options with requirements:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.3 Output to fire protection equipment type C7.10.4 Fault monitoring of fire protection equipment

154g/01

Page 83: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 73

Certificated Products LPCB Ref. No.

7.11 Delays to outputs7.12.2 Dependency on more than one alarm signal type B7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablements of addressable points10 Test conditionNote 1: Products are available in language variants as follows:

Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic

Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.XLS80e-8L Fixed build 8 loop analogue addressable control and indicating equipment.

020-695 XLS80e-8L-1, 8 Loop, PSU7A, Group 1020-695-103 XLS80e-8L-3, 8 Loop, PSU7A, Group 3020-695-104 XLS80e-8L-4, 8 Loop, PSU7A, Group 4020-695-105 XLS80e-8L-5, 8 Loop, PSU7A, Group 5

Incorporating the following as modular units:Enclosures:020-040-002 Cover Kit Extended Moulded, Light / Grey020-472-002 Backbox Kit Standard, Light Grey020-473-002 Backbox Kit Extended, Light Grey020-474-002 Backbox Kit Extended Deep, Light Grey020-475-002 Backbox Kit Double Extended, Light Grey020-476-002 Backbox Kit Double Extended Deep, Light Grey020-480-102 Main Cover Kit, Light / Grey020-481-002 Extension Cover Kit, Light / Grey020-509-002 Backbox Extension Deep Assembly Light / Grey020-621-002 256 Zone Extension Cover, Light / Grey020-541-102 PSU7A / 78Ah Battery EnclosureModules:020-708-100 Extension Chassis with Printer Kit020-644-009 Printer Assembly020-559-101 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-102 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612-100 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588-100 Honeywell Dual Loop Interface Board, (LIB)020-549-100 Honeywell Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 XLS80e-NI Fibre Optic Interface Kit020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel

Certified with the following options with requirements:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.3 Output to fire protection equipment type C7.10.4 Fault monitoring of fire protection equipment7.11 Delays to outputs7.12.2 Dependency on more than one alarm signal type B7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablements of addressable points10 Test condition

154g/01

Page 84: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

74 31 Dec 2012

Certificated Products LPCB Ref. No.

Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic

Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.XLS80e-NI 002-467-002 Network Gateway Unit, (NGU) Honeywell Protocol

Incorporating the following as modular units:020-643 XLS80e- NI Fibre Optic Interface Kit020-647-100 XLS80e-NI Network Gateway Module, (NGM) for use in XLS80e Panel020-648 PSU3A

154g/NO1

Note 1: Products are available in language variants as follows: Group 1: English, Spanish, Portuguese, Icelandic and Italian Group 3: English, Swedish, Danish, Norwegian and Finish Group 4: English, Czech and Polish Group 5: English and Cyrillic

Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.

Honeywell International Inc1500 West Dundee Road, Arlington Heights IL 60004, USATel: +1 847 797 4403 • Fax: +1 847 797 3664

Certificate No: 262z-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

XLS1000 Control and indicating equipment

Incorporating as modular units:

3-SSDC1-E Signature (Single), driver controller module3-SDDC1-E Signature (Dual), driver controller module3-AADC1-E System Sensor driver control module3-EASC-E Edwards (Single) Analogue driver controller module3-EADC-E Edwards (Dual) Analogue driver controller module3-PPS/M-230-E Primary Power Supply3-BPS/M-230-E Booster Power Supply3-BBC/M-230-E Booster Battery Charger Power Supply3-ASU Audio Source Unit3-ASU/FT-E Audio Source Unit with Fire Fighter Telephone3-ASUMX/100 100 minute extended audio memory card3ASU/4 Audio Source Unit with 4 Local Rail Modules (LRM) slots3-ZA20A 20 watt Zone Amplifier, Class A3-ZA20B 20 watt Zone Amplifier, Class B3-ZA40A 40 watt Zone Amplifier, Class A3-ZA40B 40 watts Zone Amplifier, Class B3-CPU3 Central Processor Unit EFM-2 Data Communications Filter3-ZA95 95 watt Zone Amplifier, Class A3-CAB7-E 7 Slot Cabinet3-CAB14-E 14 Slot Cabinet3-CAB21-E 21 Slot Cabinet3-CAB7D(R)-E Door for 7 Slot Cabinet, (R) indicates red3-CAB14D(R)-E Door for 14 Slot Cabinet, (R) indicates red3-CAB21D(R)-E Door for 21 Slot Cabinet, (R) indicates red3-RCC7R-E Small Remote Battery Cabinet3-RCC14R-E Medium Remote Battery Cabinet3-RCC21R-E Large Remote Battery Cabinet3-LCD Liquid Crystal Display, user interface3-BATSEN-E Remote battery cabinet interface, temperature sensing3-BATSEN Remote battery cabinet interface3-BATS Battery Shelf3-RS485A Data Communication, Class A

262z/01

Page 85: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 75

Certificated Products LPCB Ref. No.

3-RS485B Data Communication, Class B3-RS232 Serial Communications Card (Printer, etc)3-PSMON Primary Power Supply Monitor 3-IDC8/4 Initiating Device Circuits/NACS3-24R 24, Red3-24Y 24, Yellow3-24G 24, Green3-12RY Red-over-yellow pairs3-12SR 12 Switches. Red3-12SY 12 Switches. Yellow3-12SG 12 Switches. Green3-12/S1GY 12 Switches. Green over-yellow pairs3-12/S1RY 12 Switches. Red over-yellow pairs3-12/S2Y 24, Yellow, 12 Switches3-12/S2R 24, Red, 12 Switches3-6/3S1G2Y Green-over-yellow-over-yellow triads, 6 triads 3-6/3S1GYR Green-over-yellow-over-red triads, 6 triads 3-6/3S2RY Red-over-yellow-over-red triads, 6 triads3-BBCMON Booster, Battery Charger Monitor3-BPSMON Booster Power supply Monitor3-LDSM Annunciator strip support module3-LRMF Local Rail Module Filler3-FTCU MB Fire fighter Telephone Control Unit MB3-FTCU-E Fire fighter Telephone Control Unit Display3-REMICP Remote Microphone, Panel3-RCIC ASU Interconnect power and rail communication unit

XLS1000 Repeater

Incorporating as modular units:

3-RS485BA Remote Annunciator RS485 Communications.3-ANNCPU3 Remote Annunciator CPU3-LCDANN-E LCD Display and User Interface for Remote Annunciator3-ANNSM Remote (repeater) Annunciator Support Module3-REMICA Remote paging Microphone3-24Y 24, Yellow3-12/S1GY 12 Switches. Green over-yellow pairs3-6ANN-E(R) Remote Annunciator Back Box, 6 slots, with Door (R) indicates red3-10ANN-E(R) Remote Annunciator Back Box, 10 slots, with Door (R) indicates red

262z/01R

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices7.13 Alarm counter8.3 Fault Signals from points10 Test condition

Notes: 1. Scope of approval does not include system compatibility.

Mavili Elektronik Ticaret Ve Sanayi A.S.Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, TurkeyTel: +90 216 4664 505 • Fax: +90 216 4664 510E-mail: [email protected] • Website: www.mavigard.com

Certificate No: 926d to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

ML-1231.EN Maxlogic intelligent analogue addressable 1 Loop, 127 addressable devices, 64 Zone control and indicating equipment.

Incorporating the following units:

926d/01

Page 86: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

76 31 Dec 2012

Certificated Products LPCB Ref. No.

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY-0500-EN PSU unitML-1201 Optional Network module542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test conditionNotes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

ML-1241.P.EN Maxlogic intelligent analogue addressable 1 Loop, 127addressable devices, 64 Zone control and indicating equipment with printer

Incorporating the following units:

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY-0500-EN PSU unitML-1203 Printer moduleML-1201 Optional Network module542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and

fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

926d/01

Notes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

ML-1232.EN Maxlogic intelligent analogue addressable 2 Loop, 254 addressable devices, 64 Zone control and indicating equipment

Incorporating the following units:

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY- 0500-EN PSU unitML-1201 Optional Network module542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane

926d/02

Page 87: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 77

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and

fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test conditionNotes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

ML-1242.P.EN Maxlogic intelligent analogue addressable 2 Loop, 254 addressable devices, 64 Zone control and indicating equipment with printer.

Incorporating the following units:

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY- 0500-EN PSU unitML-1203 Printer moduleML-1201 Optional Network module542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and

fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

926d/02

Notes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

ML-1233.EN Maxlogic intelligent analogue addressable 3 Loop, 381 addressable devices, 64 Zone control and indicating equipment.

Incorporating the following units:

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY- 0500-EN PSU unitML-1201 Optional Network module542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and

926d/03

Page 88: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

78 31 Dec 2012

Certificated Products LPCB Ref. No.

fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test conditionNotes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

ML-1234.EN Maxlogic intelligent analogue addressable 4 Loop, 508 addressable devices, 64 Zone CIE

Incorporating the following units:

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY- 0500-EN PSU unitML-1201 Optional Network module542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and

fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

926d/03

Notes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

ML-1243.P.EN Maxlogic intelligent analogue addressable 3 Loop, 381 addressable devices, 64 Zone control and indicating equipment with printer.

Incorporating the following units:

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY- 0500-EN PSU unitML-1203 Printer moduleML-1201 Optional Network module542.188 Optional Turkish text membrane542.189 Optional English text membrane542.190 Optional Russian text membrane

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and

fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

926d/03

Page 89: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 79

Certificated Products LPCB Ref. No.

Notes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

ML-1244.P.EN Maxlogic intelligent analogue addressable 4 Loop, 508 addressable devices, 64 Zone control and indicating equipment with printer.

Incorporating the following units:

MLY-1202.EN Main MCU moduleMLY-1203 Zone LED moduleMLY-1200 SLCU moduleMLY- 0500-EN PSU unitML-1203 Printer moduleML-1201 Optional Network module542.188 Optional Turkish text membrane 542.189 Optional English text membrane 542.190 Optional Russian text membrane

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to the auctioning of outputs fire alarm devices and

fire routing equipment7.12.1 Dependencies on more than one alarm signal - Type A 7.12.2 Dependencies on more than one alarm signal - Type B7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

926d/04

Notes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN54-13.

Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.morley-ias.co.uk

Certificate No: 429c to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

ZX1Se 1 loop analogue addressable control and indicating equipment

722-001-301 1 loop multi-protocol control panel, language group M100 722-001-302 1 loop multi-protocol control panel, language group M200722-002-301 1 loop multi-protocol control panel, language group M100,

Stainless Steel722-101-301 1 loop multi-protocol control panel, language group H100722-101-302 1 loop multi-protocol control panel, language group H200

429c/04

Incorporating the following units:

795-072-100 Morley-IAS Loop Driver Card 795-068-100 System Sensor Loop Driver Card 795-058-105 Hochiki Loop Driver Card 795-066-100 Apollo XP95 / Discovery Loop Driver Card 795-044-001 Nittan Loop Driver Card 795-004-001 RS 485 Communication Module 795-005 RS232 Communication Module 124-206 Processor Card

Page 90: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

80 31 Dec 2012

Certificated Products LPCB Ref. No.

124-209-005 1 Loop Base Card 124-370 4 Line Display Card PS82-2-NFR 2A PSU

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs7.12. Dependency on more than one alarm signal: Type C8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

ZX2Se 1-2 loop analogue addressable control and indicating equipment

720-001-301 1-2 loop multi-protocol control panel, language group M100 720-001-302 1-2 loop multi-protocol control panel, language group M200720-002-301 1-2 loop multi-protocol control panel, language group M100,

Stainless Steel720-101-301 1-2 loop multi-protocol control panel, language group H100720-101-302 1-2 loop multi-protocol control panel, language group H200

429c/05

Incorporating the following units:

795-072-100 Morley-IAS Loop Driver Card 795-068-100 System Sensor Loop Driver Card 795-058-105 Hochiki Loop Driver Card 795-066-100 Apollo XP95 / Discovery Loop Driver Card 795-044-001 Nittan Loop Driver Card 795-004-001 RS 485 Communication Module 795-005 RS232 Communication Module 124-206 Processor Card 124-209-004 2 Loop Base Card 124-370 4 Line Display Card PS82-2-NFR 2A PSU

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs7.12.3 Dependency on more than one alarm signal: Type C8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

ZX5Se 1-5 loop analogue addressable control and indicating equipment

721-001-301 1-5 loop multi-protocol control panel, language group M100 721-001-302 1-5 loop multi-protocol control panel, language group M200721-002-301 1-5 loop multi-protocol control panel, language group M100,

Stainless Steel721-101-301 1-5 loop multi-protocol control panel, language group H100721-101-302 1-5 loop multi-protocol control panel, language group H200

429c/06

Incorporating the following units:

795-072-100 Morley-IAS Loop Driver Card 795-068-100 System Sensor Loop Driver Card 795-058-105 Hochiki Loop Driver Card 795-066-100 Apollo XP95 / Discovery Loop Driver Card 795-044-001 Nittan Loop Driver Card 795-004-001 RS 485 Communication Module 795-005 RS232 Communication Module 795-077-020 20 Zone LED Display Indicator Card 795-077-060 60 Zone LED Display Indicator Card 795-051-001 Internal Printer Module 124-206 Processor Card 124-403 5 Loop Base Card 124-370 4 Line Display Card PS196-4-NFR PSU

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs7.12.3 Dependency on more than one alarm signal: Type C8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Page 91: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 81

Certificated Products LPCB Ref. No.

HRZ2-8e 2 Zone 002-479-122 Language region 1, English manual002-479-222 Language region 2002-479-322 Language region 3, dual relay002-492-222 Language region 2, English manual, dual relay002-506-222 Language region 2, English manual

429c/10

HRZ2-8e 4 Zone 002-479-142 Language region 1, English manual002-479-242 Language region 2002-479-342 Language region 3, dual relay002-492-242 Language region 2, English manual, dual relay002-506-242 Language region 2, English manual

429c/11

HRZ2-8e 8 Zone 002-479-182 Language region 1, English manual002-479-282 Language region 2002-479-382 Language region 3, dual relay002-492-282 Language region 2, English user manual, dual relay002-506-282 Language region 2, English user manual

429c/12

Incorporating the following units: 020-747 8-way relay kit 020-772 4-way monitored sounder kit

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B8.9 Output to fault warning routing equipment10 Test condition

DXc1-S Single loop control and indicating equipment714-001-111 PANEL DXc1-S SINGLE LOOP REGION 1 (UK & Iceland)714-001-112 PANEL DXc1-S SINGLE LOOP REGION 2 (Iberia, India & ME)

429c/13

Incorporating as modular units: 124-410-001 Base PCB 1 Loop 124-411 Display PCB 010-115 PSU RS-50-24

DXc2-M Two loop control and indicating equipment714-001-221 PANEL DXc2-M TWO LOOP REGION 1 (UK & Iceland)714-001-222 PANEL DXc2-M TWO LOOP REGION 2 (Iberia, India & ME)

429c/14

Incorporating as modular units: 124-410 Base PCB 2 Loop 124-411 Display PCB 010-116 PSU RS-100-24

DXc4-M Four loop control and indicating equipment714-001-241 PANEL DXc4-M FOUR LOOP REGION 1 (UK & Iceland)714-001-242 PANEL DXc4-M FOUR LOOP REGION 2 (Iberia, India & ME)

429c/15

Incorporating as modular units:124-410 Base PCB 2 Loop124-411 Display PCB124-417 2 Loop PCB010-116 PSU RS-100-24

Incorporating as optional modular units:

795-099 KIT DXc NETWORK CARD795-102 KIT DXc 40 ZONE LED CARD795-103 KIT DXc 80 ZONE LED CARD WITH COVER795-111 KIT DXc 2 LOOP EXPANSION CARD (Applicable to the two loop CIE only) 795-117 KIT DXc PERFORMANCE CARD795-118 KIT DXc KEYSWITCH795-122 KIT DXc RS232795-123 KIT DXc RS485795-124 KIT DXc 80 ZONE LED CARD

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.11 Delays to outputs7.12.3 Dependencies on more than one alarm signal-Type C7.13 Alarm counter8.3 Fault signals from points

Page 92: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

82 31 Dec 2012

Certificated Products LPCB Ref. No.

9.5 Disablement of each addressable point10 Test condition

Notes:1. This product approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality.

Multron Systems Pte Ltd217 Kallang Bahru, Multron Building, Singapore 339 347, SingaporeTel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869E-mail: [email protected] • Website: www.multron.com

Certificate No: 548j-(cl-6) to EN 54-2: 1997 & EN 54-4: 1997Certificate No: 548p-(cl-3) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

MPC-101 Single zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

548j/02

MPC-102 Two zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

548j/03

MPC-104 Four zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

548j/04

MPC-108 Eight zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

548j/05

MPC-116 Sixteen zone conventional control and indicating equipment

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

548j/06

IFP2 Intelligent 2 loop, 30 zone analogue addressablecontrol and indicating equipment

Incorporating the following units:F7.820.826 Main boardF7.820.827 Switch boardF7.820.828 Loop interface boardF7.820.829b Power supply unitF7.908.312d Zone indication and intervention boardF7.820.1125 Loop board

Incorporating as optional modular units:F7.820.170 RS-232 board for configurationP-9901 Printer module kit

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10.1 Output to automatic Fire Protection Equipment Type A

548p/01

Page 93: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 83

Certificated Products LPCB Ref. No.

7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points

IFP8 Intelligent 8 loop, 140 zone analogue addressablecontrol and indicating equipment

Incorporating the following units:F7.820.1238 Indication boardF7.820.1239 Loop boardF7.820.1311 Power boardF7.820.1312 ZCP boardF7.820.1326 Keypad boardF7.820.1237 Main boardF7.820.1310 Mother board

Incorporating as optional modular units:F7.820.1313 USB communication board

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.9.2 Alarm confirmation input from fire routing equipment7.10.1 Output type A7.10.2 Output type B7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

548p/02

Nitin Ventures FZEP.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab EmiratesTel: +97 148865858/859 • Fax: +97 148865800E-mail: [email protected] • Website: www.nitinventures.com

Certificate No: 018c to EN 54-2: 1997 and EN 54-4: 1997

Certificated Products LPCB Ref. No.

Discovery 4 loop analogue addressable control and indicating equipmentIncorporating as modular units:

A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230Vac power supply control card A1599 Printer board

018c/01

Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

NV 2 2 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

018c/02

Certified with the following options with requirements from EN54-2: 19977.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs

Page 94: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

84 31 Dec 2012

Certificated Products LPCB Ref. No.

8.9 Output to fault warning equipment10 Test condition

NV 4 4 zone conventional control and indicating equipment Incorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

018c/03

Certified with the following options with requirements from EN54-2: 1997:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

NV 8 8 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

018c/04

Certified with the following options with requirements from EN54-2: 1997:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

NV 16 16 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

018c/05

Certified with the following options with requirements from EN54-2: 1997:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

NV 32 32 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power supply board C1631 Repeater interface (option)

018c/06

Certified with the following options with requirements from EN54-2: 1997:7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

NV 8R 8 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface

018c/R01

NV 16R 16 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface

018c/R02

NV 32R 32 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface

018c/R03

Page 95: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 85

Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.notifierfiresystems.co.uk

Certificate No: 154g to EN 54-2: 1997 + A1: 2006, EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

ID3000 Basic Equipment Kit, (BEK): Modular analogue addressable control and indicating equipment.020-538 Basic Equipment Kit ID3000, Group 0020-538-001 ID3000 Basic Equipment Kit, Group 1020-538-003 ID3000 Basic Equipment Kit, Group 3020-538-004 ID3000 Basic Equipment Kit, Group 4020-538-005 ID3000 Basic Equipment Kit, Group 5

154g/01

ID3002 Fixed build 2 loop analogue addressable control and indicating equipment.002-473 ID3002, 2 Loop, PSU3A, Group 0, Red002-474 ID3002, 2 Loop, PSU3A, Group 0002-474-001 ID3002, 2 Loop, PSU3A, Group 1002-474-003 ID3002, 2 Loop, PSU3A, Group 3002-474-004 ID3002, 2 Loop, PSU3A, Group 4 002-474-005 ID3002, 2 Loop, PSU3A, Group 5

154g/01

ID3004 Fixed build 4 loop analogue addressable control and indicating equipment.020-727 ID3004, 4 Loop, PSU7A, Group 0, LIB020-728 ID3004, 4 Loop, PSU7A, Group 0, ELIB020-729 ID3004, 4 Loop, PSU7A, Group 0, LIB, printer020-730 ID3004, 4 Loop, PSU7A, Group 0, LIB, 64 zone LED

154g/01

ID3006 Fixed build 6 loop analogue addressable control and indicating equipment.020-731 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB020-732 ID3006, 6 Loop, PSU7A, Group 0, 2xELIB020-733 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, printer020-734 ID3006, 6 Loop, PSU7A, Group 0, 2xLIB, 64 zone LED

154g/01

ID3008 Fixed build 8 loop analogue addressable control and indicating equipment.020-735 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure020-736 ID3008, 8 Loop, PSU7A, Group 0, 3xELIB, 78Ah Battery Enclosure020-737 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery Enclosure, Printer020-738 ID3008, 8 Loop, PSU7A, Group 0, 3xLIB, 78Ah Battery enclosure, printer, 64 Zone LED

154g/01

ID3000 series

Incorporating the following as modular units:Enclosures:020-472-009 Backbox Kit Standard, Black / Grey020-473-009 Backbox Kit Extended, Black / Grey020-474-009 Backbox Kit Extended Deep, Black / Grey020-475-009 Backbox Kit Double Extended, Black / Grey020-476-009 Backbox Kit Double Extended Deep, Black / Grey020-480-009 Cover Kit Main Moulded, Black / Grey020-481-009 Cover Kit Extended Moulded, Black / Grey020-508-009 Backbox Extension Standard Assembly Black / Grey020-509-009 Backbox Extension Deep Assembly Black / Grey020-513-009 High Security Cover Kit Main, Black / Grey020-514-009 High Security Cover Kit Extension020-576 Main Cover, Stainless Steel020-577 Extension Cover Stainless Steel020-621-256 Zone Extension Cover, Stainless / Steel020-621-009 256 Zone Extension Cover, Black / Grey020-541-009 PSU7A / 78Ah Battery Enclosure

Modules:020-559-001 Zone Extension Chassis Kit 1-64 Zone C/W Display Module020-559-002 Zone Extension Chassis Kit 65-128 Zone C/W Display Module020-612 Double Extended Chassis Kit 256 Zone020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly

Page 96: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

86 31 Dec 2012

Certificated Products LPCB Ref. No.

020-588 Notifier Dual Loop Interface Board, (LIB)020-549 Notifier Dual Enhanced Loop Interface Board, (ELIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A020-579 PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-548 PSU7A Status Indication020-543 Dual Transmission Path / Booster, PSU Interface020-773 Routing Termination Unit (DEOL)020-877 Extinguishing Interface Module M221-SI020-643 ID²net Fibre Optic Interface Kit020-647 ID²net Network Gateway Module, (NGM) for use in ID3000 Panel

Note 1: Products are available in language variants as follows:Group 0: English and Icelandic, with English manualsGroup 1: English, Spanish, Portuguese, Icelandic and ItalianGroup 3: English, Swedish, Danish, Norwegian and FinishGroup 4: English and PolishGroup 5: English and Cyrillic

Note 2: Fixed build products incorporate a corresponding Basic Equipment Kit.

ID50 Single loop analogue addressable control and indicating equipment

002-455 ID50 Panel Group 0002-455-001 ID50 Panel Group 1002-455-003 ID50 Panel Group 3002-455-004 ID50 Panel Group 4May also incorporate the following optional modular unit:002-553 RS485 Communication Kit

154g/02

ID60 Single loop analogue addressable control and indicating equipment

002-456 ID60 Panel Group 0002-456-001 ID60 Panel Group 1002-456-003 ID60 Panel Group 3002-456-004 ID60 Panel Group 4May also incorporate the following optional modular unit:002-553 RS485 Communication Kit

154g/03

ID61 Single loop analogue addressable control and indicating equipment

002-463 ID61 Panel Group 0002-463-001 ID61 Panel Group 1002-463-004 ID61 Panel Group 4002-485-001 ID61 Panel Group 1 (Red)Incorporating the following modular unit:020-648 PSU3A KitMay also incorporate the following optional modular units:020-479 RS485 Communication Kit020-644-009 Printer Kit

154g/04

ID62 Single loop analogue addressable control and indicating equipment002-461 ID62 Panel Group 0002-461-001 ID62 Panel Group 1002-461-004 ID62 Panel Group 4Incorporating the following modular unit:020-648 PSU3A KitMay also incorporate the following optional modular units:020-479 RS485 Communication Kit020-644-009 Printer Kit

154g/05

Certified with the following options with requirements:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment: Type A7.10.3 Outputs to fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11 Delays to Outputs7.12.2 Dependencies on more than one alarm signal: Type B7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Page 97: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 87

Certificated Products LPCB Ref. No.

Note: Products are available in various language groups as follows:Group 0: English, Icelandic, French, Italian, Portuguese and Spanish, (shipped with English manuals)Group 1: English, Icelandic, French, Italian, Portuguese and SpanishGroup 2: English, Dutch, German, French and ItalianGroup 3: English, Swedish, Danish, Norwegian and FinnishGroup 4: English and Polish

NFS2-8 2 Zone 002-477-122 Language region 1, light grey002-477-129 Language region 1, black & grey002-477-222 Language region 2, light grey002-477-229 Language region 2, black & grey002-477-322 Language region 3, light grey, dual relay002-477-329 Language region 3, black & grey, dual relay, English manual002-490-129 Language region 1, black & grey, dual relay, English manual002-490-229 Language region 2, black & grey, dual relay, English manual 002-490-222 Language region 2, light grey, English manua

154g/06

NFS2-8 4 Zone 002-477-142 Language region 1, light grey002-477-149 Language region 1, black & grey002-477-242 Language region 2, light grey002-477-249 Language region 2, black & grey002-477-342 Language region 3, light grey, dual relay002-477-349 Language region 3, black & grey, dual relay002-490-149 Language region 1, black & grey, dual relay, English manual002-490-249 Language region 2, black & grey, dual relay, English manual002-490-242 Language region 2, light grey, English manual

154g/07

NFS2-8 8 Zone 002-477-182 Language region 1, light grey002-477-189 Language region 1, black & grey002-477-282 Language region 2, light grey002-477-289 Language region 2, black & grey002-477-382 Language region 3, light grey, dual relay002-477-389 Language region 3, black & grey, dual relay002-490-189 Language region 1, black & grey, dual relay, English manual002-490-289 Language region 2, black & grey, dual relay, English manual002-490-282 Language region 2, light grey, English manual

Incorporating the following units:020-747 8-Way relay kit020-772 4-way monitored sounder kit

154g/08

Certified with the following options from EN 54 Part 2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment

7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to automatic fire protection equipment: Type A7.10.3 Output to automatic fire protection equipment: Type C7.10.4 Fault monitoring of fire protection equipment7.11.1 Delays to outputs7.11.2 Manual or automatic switching of delays to outputs7.12.2 Dependency on more than one alarm signal: Type B 8.9 Output to fault warning routing equipment10 Test condition

ID2000 Basic Equipment Kit, (BEK): Modular analogue addressable controland indicating equipment.020-628 Basic equipment kit ID2000 Group 0, 020-628-001Basic equipment kit ID2000 Group 1, UK ES PT IT020-628-002Basic equipment kit ID2000 Group 2, UK NL FR

154g/09

ID2002 Fixed build 2 loop analogue addressable control and indicatingequipment.002-459 ID2002, 2 loop control and indicating equipment, Group 1

Incorporating the following as optional modular units:

Enclosures:020-472-009 Backbox Kit Standard, Black / Grey020-473-009 Backbox Kit Extended, Black / Grey020-474-009 Backbox Kit Extended Deep, Black / Grey020-475-009 Backbox Kit Double Extended, Black / Grey020-476-009 Backbox Kit Double Extended Deep, Black / Grey020-480-009 Cover Kit Main Moulded, Black / Grey

154g/09

Page 98: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

88 31 Dec 2012

Certificated Products LPCB Ref. No.

020-481-009 Cover Kit Extended Moulded, Black / Grey020-508-009 Backbox Extension Standard Assembly Black / Grey020-509-009 Backbox Extension Deep Assembly Black / Grey020-576 Main Cover, Stainless Steel020-577 Extension Cover Stainless Steel020-541-009 PSU7A / 78Ah Battery EnclosureModules:020-649-009 64 Zone Extension Chassis Kit 64 Zone C/W Display Module020-708-009 Extension Chassis with Printer020-644-009 Printer Assembly020-588 Notifier Dual Loop Interface Board, (LIB)020-478 RS232 Interface020-479 RS485 Interface020-648 PSU3A

PSU7A, (Requires Dual Transmission Path / Booster, PSU Interface)020-543 Dual Transmission Path / Booster, PSU Interface020-548 PSU7A Status IndicationCertified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delays to outputs7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablements of addressable points10 Test condition

Note 2: Products are available in language variants as follows: Group 0: English, Spanish, Portuguese and Italian (shipped with English

manuals) Group 1: English, Spanish, Portuguese and Italian Group 2: English, Dutch, and French

Pearl Two loop analogue addressable control and indicating equipment

Incorporating the following units:

124-408 3A PSU board 124-412 Network gateway module124-421 Base board incorporating two loops124-422 Display board124-423 VdS I/O Module124-426 Communications modulePRL Box Extended Back box

Incorporating the following optional regional language text inserts:

PRL-EN ( English)PRL-D (German)PRL-IB (Iberia)PRL-BNL (Benelux)PRL-NRD (Swedish)PRL-MEA (Middle East and Africa)PRL-IT (Italian)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.3 Output to fire protection equipment type C7.10.4 Fault monitoring of fire protection equipment7.11 Delays to outputs7.12.2 Dependency on more than one alarm signal type B7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablements of addressable points10 Test condition

154g/10

Page 99: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 89

Certificated Products LPCB Ref. No.

Notes:1. 1. This product approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality.

002-467 ID²net Network Gateway Unit, (NGU) Notifier Protocol

Incorporating the following as modular units:020-643 ID²net Fibre Optic Interface Kit020-647 ID²net Network Gateway Module, (NGM) for use in ID3000 Panels020-648 PSU3A

154g/NO1

Certified with the following options with requirements:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.3 Output to fire protection equipment type C7.10.4 Fault monitoring of fire protection equipment7.11 Delays to outputs7.12.2 Dependency on more than one alarm signal type B7.12.3 Dependency on more than one alarm signal type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablements of addressable points10 Test condition

Olympia Electronics S.A.Kolindros Pierias, 60061, GreeceTel: (+30) 2353051200 • Fax: (+30 )2353051486E-mail: [email protected] • Website: www.olympia-electronics.gr

Certificate No: 1010a to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2 006

Certificated Products LPCB Ref. No.

BSR-2104 Two loop analogue addressable control and indicating equipment.

Incorporating the following units: 1702091 Main board 0905073 Main processor board 0506073 Input / Output Unit 1603073 LED PCB board 2307103 Loop 1 incorporating power control board DPP100-24 Lambda PSU block

Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to fire protection equipment (Type A) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.13 Alarm counter 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

1010a/01

BSR-2114 Four loop analogue addressable control and indicating equipment.

Incorporating the following units: 1702091 Main board

1010a/02

Page 100: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

90 31 Dec 2012

Certificated Products LPCB Ref. No.

0905073 Main processor board 0506073 Input / Output Unit 1603073 LED PCB board 2307103 Loop 1 incorporating power control board 2607103 Loop 2 board DPP100-24 Lambda PSU block

Certified with the following options with requirements from EN 54 part 2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.10.1 Output to fire protection equipment (Type A) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs 7.13 Alarm counter 8.3 Fault signal from points 8.9 Output to fault warning routing equipment 9.5 Disablement of each address point 10 Test condition

Orient Corporation Pte. Ltd.Block 3018, Bedok North Street 5, #05-51, Eastlink Light Industrial Building 486132, SingaporeTel: (+65) 6242 5489 • Fax: (+65) 6241 2291E-mail: [email protected]

Certificate No: 176c-(cl-1) to EN 12094-1: 2003, EN54-2: 1997 + A1: 2006 + A2: 2007 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Control and indicating equipmentCertificated Products LPCB Ref.

No.EP203/ORIENT Conventional three zone class A extinguisher control panel

Incorporating the following units:

SPF0000203 Main extinguisher control SPF0000212 External relay interface SPF0003613 Power supply unit SPF0000214 EP214 terminator

Incorporating as modular units:

EP210S Remote Status Unit Surface Mount optional (See Note 1) EP211 Economy Status Unit optional (See Note 1)

Certified with the following options with requirements from EN 12094-1:2003

4.17 Delay of extinguishing signal 4.18 Signal representing the flow of extinguishing agent 4.19 Monitoring of the status of components 4.20 Emergency hold device 4.21 Control of flooding time 4.23 Manual only mode 4.26 Triggering of equipment outside the system 4.27 Emergency abort device 4.30 Activation of alarm devices with different signals

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s) 7.11 Delays to the auctioning of outputs fire alarm devices and fire

routing equipment 7.13 Alarm counter 10 Test condition

176c/01

Note:1. Optional Remote Status Unit part No. EP210S & Economy Status Unit part No. EP211

Page 101: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 91

Certificated Products LPCB Ref. No.

are not certified as meeting the requirements of the standards specified.

2. Meets the requirements of EN12094-3:2003, Class A - i.e. operational temperature range of -5°C to +40°C.

Pelco Finland OyKalkkipellontie 6, 02650, Espoo, FinlandTel: +358 10 446 511 • Fax: +358 10 446 5103E-mail: [email protected] • Website: www.pelco.com/nordic

Manufactured at:Pelco Finland Oy, Manttaalitie 5-7, 01530 Vantaa, Finland

Certificate No: 883b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

FX 8 Loop Analogue addressable CIE

Basic unit incorporates the following modules:

FX-MC2 Master controllerFX-UI2 User interfaceFX-PSB 4.5 A Power Supply orFX-PSA 2.2 A Power Supply

Optional Modules -The following modules are optional additions to the basic unit:

FX-ALCB Two loop addressable controller - Apollo protocol card FX-ALCA One loop addressable controller - Apollo protocol cardFX-LC Two loop addressable controller - System Sensor protocol cardFX-SLC Two loop addressable controller - System Sensor advanced protocol cardFX-CLC Sixteen loop conventional ControllerFX-IOC I/O controller boardFX-OCA 16 clean output moduleFX-LB80 80 Zone LED indication cardFX2-LB32 32 Panel LED indication cardFX-BAT Separate battery box (4x17Ah, 12V)FXM-BAT Separate battery box (4x12Ah, 12V)

Certified with the following options with requirements from EN 54-2:

7.8 Outputs to fire alarm devices7.9.1 Output to fire alarm routing equipment7.10.3 Output to Fire Protection Equipment (Output Type C)7.11 Delays to outputs7.12.2 Dependencies on more than one alarm signal (Type B)7.13 Alarm counter8.3 Fault signals from points8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:1. Scope of approval does not include the operation of the network functionality. 2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

883b/01

FXL 8 Loop Analogue addressable CIE

Basic unit incorporates the following modules:

883b/02

Page 102: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

92 31 Dec 2012

Certificated Products LPCB Ref. No.

FX-MC2 Master controllerFX-UI2 User interfaceFX-PSB 4.5 A Power Supply orFX-PSA 2.2 A Power Supply

Optional Modules -The following modules are optional additions to the basic unit:

FX-ALCB Two loop addressable controller - Apollo protocol card FX-ALCA One loop addressable controller - Apollo protocol cardFX-LC Two loop addressable controller - System Sensor protocol cardFX-SLC Two loop addressable controller - System Sensor advanced protocol cardFX-CLC Sixteen loop conventional ControllerFX-IOC I/O controller boardFX-OCA 16 clean output moduleFX-LB80 80 Zone LED indication cardFX2-LB32 32 Panel LED indication cardFX-BAT Separate battery box (4x17Ah, 12V)FXM-BAT Separate battery box (4x12Ah, 12V)

Certified with the following options with requirements from EN 54-2:

7.8 Outputs to fire alarm devices7.9.1 Output to fire alarm routing equipment7.10.3 Output to Fire Protection Equipment (Output Type C)7.11 Delays to outputs7.12.2 Dependencies on more than one alarm signal (Type B)7.13 Alarm counter8.3 Fault signals from points8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes: 1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

FXM 4 Loop Analogue addressable CIE

Basic unit incorporates the following modules:

FX-MC2 Master ControllerFX-UI2 User InterfaceFX-PSB 4.5 A Power Supply orFX-PSA 2.2 A Power Supply

Optional Modules -The following modules are optional additions to the basic unit:

FX-ALCB Two loop addressable controller - Apollo protocol card FX-ALCA One loop addressable controller - Apollo protocol cardFX-LC Two loop addressable controller - System sensor protocol cardFX-SLC Two loop addressable controller - System Sensor advanced protocol cardFX-CLC Sixteen loop conventional ControllerFX-IOC I/O controller boardFX-OCA 16 clean output moduleFX-LB80 80 Zone LED indication cardFX2-LB32 32 Panel LED indication cardFX-BAT Separate battery box (4x17Ah, 12V)FXM-BAT Separate battery box (4x12Ah, 12V)

Certified with the following options with requirements from EN 54-2:

7.8 Outputs to fire alarm devices7.9.1 Output to fire alarm routing equipment7.10.3 Output to Fire Protection Equipment (Output Type C)7.11 Delays to outputs7.12.2 Dependencies on more than one alarm signal (Type B)7.13 Alarm counter8.3 Fault signals from points8.4 Total loss of the power supply

883b/03

Page 103: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 93

Certificated Products LPCB Ref. No.

8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:1. Scope of approval does not include the operation of the network functionality.2. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

FXS Analogue addressable Repeater Panel

Incorporating the following modules:

FX-MC2 Master ControllerFX-UI2 User Interface

Optional Modules -The following modules are optional additions to the basic unit:

FX-IOC I/O Controller

883b/R01

Photain Controls8 New Market Court, Chippenham Drive, Kingston, Milton Keynes MK10 0AQ, United KingdomTel: 01908 281981 • Fax: 01908 282554E-mail: [email protected]

Certificate No: 092h to BS EN 54 - 2: 1998 and BS EN 54- 4: 1998 N.B. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). Thiscertificate, to the withdrawn standard, is maintained because controland indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU

Certificated Products LPCB Ref. No.

System 2000 PAI System 2000 PAI

Incorporating as modular units:

ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus driver ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-Xl 230Vac Power supply unit

Approved with the following options from BS EN54 Part 2:

7.8 Output to fire alarm devices7.9 Output to fire alarm routing equipment7.10 Output to fire protection equipment7.11 Delays to outputs7.12 Co-incidence detection7.13 Alarm counter8.3 Fault signals from points8.4 Total loss of power8.9 Output to fault routing equipment9.5 Disablement of addressable points10 Test condition11 Standardised input/output interface

092h/01

Page 104: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

94 31 Dec 2012

Protec Fire Detection plcProtec House, Churchill Way, Nelson, Lancashire BB9 6RT, United KingdomTel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273E-mail: [email protected] • Website: www.protec.co.uk

Certificate No: 201ad to EN 54-2: 1997+A1: 2006 and EN 54-4: 1997+A1: 2002+A2: 2006

Certificated Products LPCB Ref. No.

6304 4 Loop Analogue addressable control and indicating equipment

Incorporating the following units:

SF41-860-52F Main BoardSF41-850-50C Terminal BoardSF40-877-65 CP250 Printer Board31-100-22 Backbox 31-243-36 Inner Plate62-407-57 Door04-701-38 Printer MechanismSF40-465-43F Series 9000 Power Supply UnitSF41-913-56B SMT Dual 6000 Loop Card31-275-44 Optional external 24 AH battery boxSF40-879-67G Network Card

Certified with the following options with requirements from EN 54: Part 2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

201ad/09

Note:1. Scope of approval does not include the operation of the network functionality.

6400/DCN Display and Control node

Incorporating the following units:

SF40-855-65E Display control unitSF40-811-47E Local display unitSF40-821-49E PF Terminal unit

Certified with the following options with requirements from EN 54: Part 2: 7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of each address point10 Test condition

201ad/01

Notes:

1. This unit does not meet the requirements of EN 54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop processing node

6400/PSU 8A Power supply with charger2. Scope of approval does not include the operation of the network functionality.

Page 105: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 95

Certificated Products LPCB Ref. No.

6400/2LPN 2 Loop processing node

Incorporating the following units:

SF40-812-48E SSUSF40-814-50E Local IOSF40-817-53C Terminal boardSF40-819-55D 6400 Loop terminal boardSF40-818-54 LPN display boardSF40-826-54C 6400 OPTO isolated 485 boardSF40-913-56B 6400 Loop Transmission board

201ad/02

Notes: 1. This unit does not meet the requirements of EN 54-2

& 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

6400/DCN Display and Control node 6400/PSU 8A Power supply with charger

2. Scope of approval does not include the operation of the network functionality.

6400/4LPN 4 Loop processing node

Incorporating the following units:

SF40-812-48E SSUSF40-814-50E Local IOSF40-817-53C 5400 Terminal boardSF40-819-55D 6400 Loop terminal boardSF40-818-54 LPN display boardSF40-826-54C 6400 OPTO 485 boardSF40-913-56B 6400 Loop Transmission board

201ad/03

Notes: 1. This unit does not meet the requirements of EN

54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

6400/DCN Display and Control node 6400/PSU 8A Power supply with charger

2. Scope of approval does not include the operation of the network functionality.

6400/DCN/2LPN Display and control node plus 2 Loop processing node

Incorporating the following units:

SF40-855-65E Display control unitSF40-811-47E 5400 LED display unitSF40-812-48E SSUSF40-814-50E Local IOSF40-817-53C 5400 Terminal boardSF40-819-55D 6400 Loop terminal boardSF40-826-54C 6400 OPTO isolated 485 boardSF40-913-56B 6400 Loop Transmission board

Certified with the following options with requirements from EN 54: Part 2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of each address point10 Test condition

201ad/04

Notes: 1. This unit does not meet the requirements of EN

54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire

Page 106: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

96 31 Dec 2012

Certificated Products LPCB Ref. No.

alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

6400/PSU 8A Power supply with charger2. Scope of approval does not include the operation of the network functionality.

6400/DCN/4LPN Display and control node plus 4 Loop processing node

Incorporating the following units:

SF40-855-65E Display control unitSF40-811-47E 5400 Local display unitSF40-812-48E SSUSF40-814-50E Local IOSF40-817-53C 5400 Terminal boardSF40-819-55D 6400 Loop terminal boardSF40-826-54C 6400 OPTO isolated 485 boardSF40-913-56B 6400 Loop Transmission board

Certified with the following options with requirements from EN 54: Part 2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs7.12.3 Dependencies on more than one alarm signal - Type C7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of each address point10 Test condition

201ad/05

Notes: 1. This unit does not meet the requirements of EN

54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

6400/PSU 8A Power supply with charger2. Scope of approval does not include the operation of the network functionality.

6400/PSU 8A Power supply with charger

Incorporating the following units:

SF40-472-48H-3 8A Power supply with charger

201ad/06

Notes: 1. This unit does not meet the requirements of EN

54-2 & 4 as a stand alone unit. It is intended for use as part of the 6400 distributed network fire alarm system. In order to meet the requirements of EN 54-2 & 4 the unit must be used in conjunction with the following units:

6400/DCN Display and Control node 6400/2LPN 2 Loop processing node and/or 6400/4LPN 4 Loop

processing node2. Scope of approval does not include the operation of the network functionality.3. Certified to EN 54-4 only.

6301 1 Loop Analogue addressable control and indicating equipment

Incorporating the following units:

SF41-860-52F Main BoardSF41-850-50C Terminal BoardSF40-877-65 CP250 Printer Board31-100-22 Backbox 31-243-36 Inner Plate62-407-57 Door04-701-38 Printer MechanismSF40-465-43F Series 9000 Power Supply Unit31-275-44 Optional external 24 AH battery box

201ad/07

Page 107: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 97

Certificated Products LPCB Ref. No.

SF40-879-67G Network Card

Certified with the following options with requirements from EN 54: Part 2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test conditionNote:1. Scope of approval does not include the operation of the network functionality.

6302 2 Loop Analogue addressable control and indicating equipment

Incorporating the following units:

SF41-860-52F Main BoardSF41-850-50C Terminal BoardSF40-877-65 CP250 Printer Board31-100-22 Backbox 31-243-36 Inner Plate62-407-57 Door04-701-38 Printer MechanismSF40-465-43F Series 9000 Power Supply Unit31-275-44 Optional external 24 AH battery boxSF40-879-67G Network Card

Certified with the following options with requirements from EN 54: Part 2

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.11 Delays to outputs 7.12.3 Dependencies on more than one alarm signal Type C7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

201ad/08

Note:1. Scope of approval does not include the operation of the network functionality.

Schneider Electric Buildings Sweden ABDialoggatan 16, 126 37, Hägersten, NorwayTel: +4687752700 • Fax: +4687449802E-mail: [email protected] • Website: www.schneider-electric.com

Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

CFP704-4/SCAN/S Four zone conventional control and indicating equipment

Incorporating the units:

RPF0702005 Power supply PCBSPF0724853 4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/13

Page 108: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

98 31 Dec 2012

Schneider Electronic Buildings ASLuhrtoppen 2, N-1470, Lørenskog, NorwayE-mail: [email protected] • Website: www.schneider-electric.no

Certificate No: 176b to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

EPC4 Four zone conventional control and indicating equipment

Incorporating the units:

RPF0702005 Power supply PCBSPF0724853 4 Zone main control board

Certified with the following options with requirements from EN 54-2: 1997

7.8 Output to fire alarm devices(s)7.11 Delays to outputs10 Test condition

176b/13

SHIELD FIRE, SAFETY AND SECURITY LTD29th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United KingdomTel: +44 207 712 1610 • Fax: +44 207 712 1578E-mail: [email protected] • Website: www.shieldglobal.com

Certificate No: 548j to EN 54-2:1997 & EN54-4:1997Certificate No: 548p-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

P-A300 Intelligent 1 loop, 30 zone analogue addressable control and indicating equipment

Incorporating the following units:F7.820.826 Main boardF7.820.827 Switch boardF7.820.828 Loop interface boardF7.820.829 Power supply unitF7.908.312 Zone indication boardCGM12864 Alphanumeric displayF2.910.093 Mains filterR150 TransformerF2.828.630a Printer board (option)

Incorporating as optional modular units:F7.820.170 RS-232 board for configurationP-9901 Printer module kit

548j/01

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10 Output to automatic Fire Protection Equipment7.11 Delays to outputs7.12 Coincidence detection8.3 Fault signals from points9.5 Disablement of addressable points

P-C201 Single zone conventional control and indicating equipment 548j/02Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

P-C202 Two zone conventional control and indicating equipment 548j/03Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices10 Test condition

P-C204 Four zone conventional control and indicating equipment 548j/04

Page 109: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 99

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

P-C208 Eight zone conventional control and indicating equipment 548j/05Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

P-C216 Sixteen zone conventional control and indicating equipment 548j/06Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.11 Delays to outputs10 Test condition

P-A2M Intelligent 2 loop, 30 zone analogue addressable control and indicating equipment

Incorporating the following units:F7.820.826 Main boardF7.820.827 Switch boardF7.820.828 Loop interface boardF7.820.829b Power supply unitF7.908.312d Zone indication and intervention boardF7.820.1125 Loop board

Incorporating as optional modular units:F7.820.170 RS-232 board for configurationP-9901 Printer module kit

Certified with the following options with requirements from EN 54 part 2:7.8 Output to Fire Alarm Devices7.10.1 Output to automatic Fire Protection Equipment Type A7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points

548p/01

P-A8M Intelligent 8 loop, 140 zone analogue addressable control and indicating equipment

Incorporating the following units:F7.820.1238 Indication boardF7.820.1239 Loop boardF7.820.1311 Power boardF7.820.1312 ZCP boardF7.820.1326 Keypad boardF7.820.1237 Main boardF7.820.1310 Mother board

Incorporating as optional modular units:F7.820.1313 USB communication board

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices7.9.1 Output to fire routing equipment7.9.2 Alarm confirmation input from fire routing equipment7.10.1 Output type A7.10.2 Output type B7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal Type A7.12.2 Dependencies on more than one alarm signal Type B7.13 Alarm counter8.3 Fault signals from points9.5 Disablement of each address point10 Test condition

548p/02

Page 110: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

100 31 Dec 2012

Siemens Switzerland Limited, Building Technologies DivisionInternational Headquarters, Gubelstrasse 22, CH-6301 Zug, SwitzerlandTel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22

Manufacturing at:Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, SwitzerlandTel: +41 1 922 6111 • Fax: +41 1 922 6450

UK Sales:Fire Safety and Security LimitedTel: +44 (0)1734 783703 • Fax: +44 (0)1734 775750

Certificate No: 126h-(cl1) to EN 54-2: 1997 and EN 54-4: 1997Certificate No: 126aw-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 126aw-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

FC2020 Control and indicating equipment

Incorporating as modular units:

FCM2028 Operating unit FP2001-A1 70W Power supply FCI2002-A1 Periphery board (2-Loop) FHA2002-A1 Rear housing

and as optional modular units:

FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2005-A2 Operating add-on module FCM2006-A2 Operating add-on module (2 LED indicator) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC- module (NL) SV 24V-150W 150W Power supply REDUX Redundancy module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm Confirmation from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment Type A 7.10.2 Output to automatic fire protection equipment Type B 7.10.3 Output to automatic fire protection equipment Type C 7.10.4 Fault monitoring of automatic fire protection equipment 7.11 Delays to outputs 7.12.2 Coincidence detection type B (only for FDnet & MS9i line

technology) 7.12.3 Coincidence detection type C 7.13 Alarm counter

126aw/01

Page 111: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 101

Certificated Products LPCB Ref. No.

8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FC2030 Control and indicating equipment

Incorporating as modular units:

FCM2028 Operating unit SV24V-150W 150W Power supply FCI2002-A1 Periphery board (2-Loop) FHA2003-A1 Rear housingFCA2007-A1 Card cage (2 slot)

and as optional modular units:

FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FCM2015-D1 Operating add-on (DA ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FTO2003-D1 Emergency alarm indicator FCA2006-A1 Connection mod. (Card Cage) FCI2008-A1 I/O card (programmable) FCL2001-A1 Line card (FDnet) FCL2002-A1 Line card (collective) FCL2003-A1 Line card (MS9i) REDUX Redundancy module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm Confirmation from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment Type A 7.10.2 Output to automatic fire protection equipment Type B 7.10.3 Output to automatic fire protection equipment Type C 7.10.4 Fault monitoring of automatic fire protection equipment 7.11 Delays to outputs 7.12.1 Coincidence detection type A (only for MS9i & collective line

technology) 7.12.2 Coincidence detection type B (only for FDnet & MS9i line

technology) 7.12.3 Coincidence detection type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition

126aw/02

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FC2040 Control and indicating equipment 126aw/03

Page 112: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

102 31 Dec 2012

Certificated Products LPCB Ref. No.

Incorporating as modular units;

FCM2028 Operating unit FCM2007-A2 Operating add-on (4 LED ind.) SV24V-150W 150W Power supply FCI2004-A1 Periphery board (4-Loop) FHA2003-A1 Rear housing

and as optional modular units:

FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2005-A2 Operating add-on module FCM2006-A2 Operating add-on module (2 LED indicator) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC- module (NL) REDUX Redundancy module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm Confirmation from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment Type A 7.10.2 Output to automatic fire protection equipment Type B 7.10.3 Output to automatic fire protection equipment Type C 7.10.4 Fault monitoring of automatic fire protection equipment 7.11 Delays to outputs 7.12.2 Coincidence detection type B (only for FDnet & MS9i line

technology) 7.12.3 Coincidence detection type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FC2060 Control and indicating equipment

Incorporating as modular units:

FCM2028 Operating unit SV24V-150W 150W Power supply FCI2004-A1 Periphery board (4-Loop) FHA2005-A1 Rear housingFCA2008-A1 Card cage (5 slot)

and as optional modular units:

FCM2029-A2 Operating unit FCM2027 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FCM2015-D1 Operating add-on (DA ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet)

126aw/04

Page 113: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 103

Certificated Products LPCB Ref. No.

FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module FTO2003-D1 Emergency alarm indicator FCA2006-A1 Connection mod. (Card Cage) FCI2008-A1 I/O card (programmable) FCL2001-A1 Line card (FDnet) FCL2002-A1 Line card (collective) FCL2003-A1 Line card (MS9i) REDUX Redundancy module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm Confirmation from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment Type A 7.10.2 Output to automatic fire protection equipment Type B 7.10.3 Output to automatic fire protection equipment Type C 7.10.4 Fault monitoring of automatic fire protection equipment 7.11 Delays to outputs 7.12.1 Coincidence detection type A (only for MS9i & collective line

technology) 7.12.2 Coincidence detection type B (only for FDnet & MS9i line

technology) 7.12.3 Coincidence detection type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FC721 Control and indicating equipment

Incorporating as modular units:

FCM7204-Z3 Operating unit FP2001-A1 70W Power supply FCI2010-A1 Periphery board (1-Loop) FHA2002-A1 Rear housing

and as optional modular units:

FCM7205-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2027 PMI- & mainboard FTO2001-A1 Event printer FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm Confirmation from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment Type A 7.10.2 Output to automatic fire protection equipment Type B 7.10.3 Output to automatic fire protection equipment Type C 7.10.4 Fault monitoring of automatic fire protection equipment 7.11 Delays to outputs

126aw/05

Page 114: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

104 31 Dec 2012

Certificated Products LPCB Ref. No.

7.12.2 Coincidence detection type B (only for FDnet & MS9i line technology)

7.12.3 Coincidence detection type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FC722 Control and indicating equipment

Incorporating as modular units:

FCM7204-Z3 Operating unit SV24V/150W 150W Power supply FCI2002-A1 Periphery board (2-Loop) FHA2003-A1 Rear housing

and as optional modular units:

FP2001-A1 70W Power supply FHA2001-A1 Rear housing FCM7205-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2027 PMI- & mainboard FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module REDUX Redundancy module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm Confirmation from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment Type A 7.10.2 Output to automatic fire protection equipment Type B 7.10.3 Output to automatic fire protection equipment Type C 7.10.4 Fault monitoring of automatic fire protection equipment 7.11 Delays to outputs 7.12.2 Coincidence detection type B (only for FDnet & MS9i line

technology) 7.12.3 Coincidence detection type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition

126aw/06

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FC724 Control and indicating equipment

Incorporating as modular units:

FCM7204-Z3 Operating unit SV24V/150W 150W Power supply FCI2004-A1 Periphery board (4-Loop)

126aw/07

Page 115: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 105

Certificated Products LPCB Ref. No.

FHA2003-A1 Rear housing

and as optional modular units:

FCM7205-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2027 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FTO2001-A1 Event printer FCI2003-A1 Loop extension (FDnet) FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCI2001-D1 Fire brigade periphery module REDUX Redundancy module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm Confirmation from fire alarm routing equipment 7.10.1 Output to automatic fire protection equipment Type A 7.10.2 Output to automatic fire protection equipment Type B 7.10.3 Output to automatic fire protection equipment Type C 7.10.4 Fault monitoring of automatic fire protection equipment 7.11 Delays to outputs 7.12.2 Coincidence detection type B (only for FDnet & MS9i line

technology) 7.12.3 Coincidence detection type C 7.13 Alarm counter 8.3 Fault signals from points 8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points 10 Test condition

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FC726 Control and indicating equipment

Incorporating as modular units:

FCM7204-Z3 Operating unitSV24V/150W 150W Power supplyFCI2004-A1 Periphery board (4-Loop)FHA2005-A1 Rear housingFCA2008-A1 Card cage (5 slot)

and as optional modular units:

FCM7205-Y3 Operating unit (+ LED Ind.)FCM2027 PMI- & mainboard FCM2007-A2 Operating add-on module (4 LED ind.) FCM2015-DA Operating add-on module (DA ind.)FTO2001-A1 Event printerFCI2003-A1 Loop extension (FDnet)FTO2002-A1 24 LED indicator (internal)FN2001-A1 Networking module (See Note 1)FN2008-A1 Ethernet Switch (See Note 1)FCA2001-A1 Isolated RS232 moduleFCA2002-A1 Isolated RS485 moduleFCI2001-D1 Fire brigade periphery moduleFTO2003-D1 Emergency alarm indicatorFCA2006-A1 Connection mod. (Card Cage)FCI2008-A1 I/O card (programmable)FCL2001-A1 Line card (FDnet)FCL2002-A1 Line card (collective)

126aw/08

Page 116: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

106 31 Dec 2012

Certificated Products LPCB Ref. No.

FCL2003-A1 Line card (MS9i)REDUX Redundancy module

Certified with the following Options with requirements from EN 54-2:

7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm Confirmation from fire alarm routing

equipment7.10.1 Output to automatic fire protection equipment Type

A7.10.2 Output to automatic fire protection equipment Type

B7.10.3 Output to automatic fire protection equipment Type

C7.10.4 Fault monitoring of automatic fire protection

equipment7.11 Delays to outputs7.12.1 Coincidence detection type A (only for MS9i &

collective line technology)7.12.2 Coincidence detection type B (only for FDnet &

MS9i line technology)7.12.3 Coincidence detection type C7.13 Alarm counter8.3 Fault signals from points 8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Note:

Scope of approval does not include the operation of the network functionality.

This approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

FT2040 Fire detection terminal for use with FC2020, FC2030, FC2040 & FC2060 control and indicating equipment

Incorporating as modular units:

FCM2029-A2 Operating unit FTI2001-A1 Fire terminal board FHA2001-A1 Rear housing

and as optional modular units:

FCM2028 Operating unit FCM2027 PMI- & mainboard FTO2001-A1 Event printer FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FCM2003-C2 Operating unit (incl. FBA-Term.CH) FCM2003-N2 Operating unit (incl. EVAC-Term.NL) FTO2004-C1 PCB compl. FBA-Terminal (CH) FTO2007-N1 PCB compl. EVAC- module (NL) FP2001-A1 70W Power supply H28G200 Housing base REDUX Redundancy module

126aw/R01

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

FT724 Fire detection terminal for use with FC721, FC722 & FC724 control and indicating equipment

Incorporating as modular units:

126aw/R02

Page 117: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 107

Certificated Products LPCB Ref. No.

FCM7204-Z3 Operating unit FTI2001-A1 Fire terminal board FHA2001-A1 Rear housing

and as optional modular units:

FCM7205-Y3 Operating unit (+ LED Ind.) FCM7203-H3 Operating unit (+ EVAC-Term.) FCM2027 PMI- & mainboard FTO2001-A1 Event printer FTO2002-A1 24 LED indicator (internal) FN2001-A1 Networking module (See Note 1) FN2008-A1 Ethernet Switch (See Note 1) FCA2001-A1 Isolated RS232 module FCA2002-A1 Isolated RS485 module FP2001-A1 70W Power supply H28G200 Housing base REDUX Redundancy module

Note: 1) Scope of approval does not include the operation of the network

functionality.2) This approval does not constitute compliance with the fire detection

and alarm systems requirements of EN 54-13.

CS1140 Control and indicating equipmentComprising the following products:

CC1140 Control and indicating equipment CT11 Operators console CI1140 Integrated central unit

Incorporating as modular units: E3X100 Master module

E3X102 Master Module E3X103 Master Module E3X120 Master card Cl1145 E3C010 Battery charging module E3C011 Battery charging module B2F020 Converter B2F040 Converter E3M140 Line module FD20 E3M070 Line module "Interactive" E3M071 Line module Interactive K3M140 Line card FD20 K3M071 Line card Interactive to E3X120 K3M080 Line card Collective B3Q460 Control console Algopilot "CT11" B3Q321 Fire department control panel (Swiss) E3G050 Contacts control unit E3G070 Universal control unit E3I020 RS232 unit K3I060 RS232 module E3L020 I/O control unit E3M080 Group line unit K3R071 Synoptic - Algo pilot K3R070 Synoptic - Algo pilot K3I050 LON/Synoptic converter E3M060 MS9i module E3G091 Remote TX i/face E3M110 AnalogPLUS module E3M111 Line module AnaloguPLUS K3M111 Line card AnalogPLUS B3R051 Parallel indicator panel (24 x 2 LED) E3G080 Control module Extinguishing B3Q440 Control console Extinguishing module E3G060 Control monitored module E3H020 C-Bus Gateway module E3I040 I-Bus/LON module B3Q560/B3Q600 Terminals China B3Q580 Text display terminal B3Q590 Text control terminal Nordic B3Q660 Operator console Standard Algopilot "CT11"

126h/01

Page 118: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

108 31 Dec 2012

Certificated Products LPCB Ref. No.

B3Q661 Operator console Standard Algopilot "CT11" B3Q680 Control console Nordic Algopilot "CT11" B3Q565 Operator control Asia Pacific Algopilot "CT11" K3N010 RAM - ExtensionK3I110 LON Input/Output Box

E3M171 Line Module Ex Interactive K5L020 Multi-Sect. Extinguishing P.C.B K3G060 Relay Card to Synptic BUS E3G100 Emergency Operation Link E3G110 Emergency Link to E3G080 K3R072 Synoptical Driver M3C080 Horn Monitoring Module

Certified with the following Options with requirements from EN 54-2:19977.8 Outputs to fire alarm devices7.9 Output to fire alarm routing equipment7.10 Output to Fire Protection Equipment7.11 Delays to outputs7.12 Coincidence detection7.13 Alarm counter8.3 Fault signals from points8.4 Complete failure of power supply9.5 Disablement of addressable points10 Test condition11 Standardised input/output interface

Notes:1) Compliance with clause 12.6.2 of EN 54-2:1997 requires LCD screen saving feature to be disabled for the alarm condition.

SMS (Novar Systems Ltd)Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016Website: www.smsfire.co.uk

Certificate No: 042bc to EN 54-2: 1997+ A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

Sentri1 Single loop analogue addressable control and indicating equipment 042bc/01Incorporating as modular units:

2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface)

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition

Sentri1-SP Single loop analogue addressable control and indicating equipment(Spanish language variant)

042bc/02

Incorporating as modular units: 2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface)

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition

Sentri1-PO Single loop analogue addressable control and indicating equipment(Portuguese language variant)

042bc/03

Incorporating as modular units:

Page 119: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 109

Certificated Products LPCB Ref. No.

2434-881 Mother board 2434-862 Power supply 2434-887 H.M.I (Human Machine Interface)

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 10 Test condition

Sentri2 Two loop analogue addressable control and indicating equipment (English language) 042bc/04Sentri2-PO Two loop analogue addressable control and indicating equipment (Portuguese language

variant)042bc/05

Sentri2-SP Two loop analogue addressable con(Spanish language variant) control and indicating equipment

042bc/06

Incorporating as modular units:

2434-859 Master Controller Board (MCB) 2434-862 Power Supply Unit 2434-762 Display and Key card (DKC) 2434-669 Loop processor card 4374-164 Text Membrane (English) 4374-169 Text Membrane (Spanish) 4374-170 Text Membrane (Portuguese) 2434-861 Copper network card Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

Sentri4 One to Four loop analogue addressable control and indicating equipment (English language)

042bc/07

Sentri4-PO One to Four loop analogue addressable control and indicating equipment (Portuguese language variant without printer module)

042bc/09

Sentri4-SP One to Four loop analogue addressable control and indicating equipment (Spanish language variant without printer module)

042bc/10

Incorporating as modular units

2434-863 Master controller card (M.C.C) 2434-710 Loop card 2434-831 Power supply PCB 2434-854 Backplane PCB 2434-861 Display and Key card (D.K.C) 2434-864 Terminal card 2434-565 Printer Module 4374-167 Text Membrane (English) 4374-171 Text Membrane (Spanish) 4374-172 Text Membrane (Portuguese) 2434-674 Copper network card Scope of approval does not include the operation of the network card)

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices 7.11 Delays to outputs 8.3 Fault signals from points 9.5 Disablement of each address point 10 Test condition

Page 120: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

110 31 Dec 2012

Thorn Security Limited, Trading as Tyco Safety ProductHanworth Road, Sunbury on Thames, London TW16 5DB, United KingdomTel: 01932 743268 • Fax: 01932 743292E-mail: [email protected] • Website: www.Tycoemea.com

Certificate No: 018c-(cl-3) to EN54-2: 1997, EN54-4: 1997Certificate No: 018f-(cl-1) to EN 54-2: 1997 + A1: 006 & EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018g-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018h-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018j-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018k-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018m-(cl-1) to EN 54-2: 1997 + A1: 2006 & EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018q-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018r-(cl-1) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006Certificate No: 018n-(cl-1) to EN 54-4: 1997 + A1: 2002 + A2: 2006

Control & Indicating EquipmentCertificated Products LPCB Ref.

No.MZXC+ 2 zone conventional control and indicating equipment

Incorporating as modular units:

C1627 Mother boardC1628 Display boardC1631 Repeater interface (option)

018c/02

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

MZXC+ 4 zone conventional control and indicating equipment

Incorporating as modular units:

C1627 Mother boardC1628 Display boardC1631 Repeater interface (option)

018c/03

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

MZXC+ 8 zone conventional control and indicating equipment

Incorporating as modular units:

C1627 Mother boardC1628 Display boardC1631 Repeater interface (option)

018c/04

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

MZXC+ 16 zone conventional control and indicating equipment

Incorporating as modular units:

C1627 Mother boardC1628 Display boardC1631 Repeater interface (option)

018c/05

Certified with the following options from EN 54: Part 2

Page 121: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 111

Certificated Products LPCB Ref. No.

7.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

MZXC+ 32 zone conventional control and indicating equipment

Incorporating as modular units:

C1627 Mother boardC1629 Display boardC1632 16 Zone expansion boardC1652 5A Power Supply boardC1631 Repeater interface (option)

018c/06

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

MZXC+ 8 zone conventional repeater unit

Incorporating as modular units:

C1627 Mother boardC1628 Display boardC1631 Repeater interface

018c/R01

MZXC+ 16 zone conventional repeater unit

Incorporating as modular units:

C1627 Mother boardC1628 Display boardC1631 Repeater interface

018c/R02

MZXC+ 32 zone conventional repeater unit

Incorporating as modular units:

C1627 Mother boardC1629 Display boardC1631 Repeater interface

018c/R03

MX4000 2-8 2-8 loop Analogue Addressable Control and Indicating Equipment 018f/01Note:1. The following product variants are approved - Finished goods No. 557.200.003, MX4000 1-4 loop CIE, shallow housingFinished goods No. 557.200.005, MX-BBX battery box, shallow housingFinished goods No. 557.200.004, MX4000 1-8 loop CIE, deep housingFinished goods No. 557.200.006, MX-DPBX battery box, deep housing (door access) Finished goods No. 557.200.016, MX-DPBX battery box, deep housing (plain cover access)Finished goods No. 557.200.009, MX4000 1-4 loop, flush housing Finished goods No. 557.200.019, MX-BBX-F battery box, flush housing

Incorporating as modular units:

OCM800 Operator Control ModuleODM800 Operator Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module drives 1 or 2 loopsPSU830 Power Supply Module

and as optional modular units:

XLM800 Expansion Loop Module drives 1 or 2 additional loopsANN840 40 + 40 LED Annunciator moduleANN880 80 LED Annunciator moduleCOM820 20 way Status Command Module MPM800 Multi Purpose Interface Module IOB800 Input/Output Expansion BoardFB800 Fuse Board

Page 122: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

112 31 Dec 2012

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

MXR Repeater panel is approved for use with the MX4000 Control and Indicating Equipment: 018f/R01Note: 1. The following product variants are approved -Finished goods No. 557.200.013, MXR-PSU repeaterFinished goods No. 557.200.018, MXR-PSU-F repeater flush housingFinished goods No. 557.200.012, MXR repeaterFinished goods No. 557.200.017, MXR-F repeater flush housing

Incorporating as modular units:

OCM800 (Operator Control Module)ODM800 (Operator Display Module)PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)ANN880 (80 LED Annunciator)MPM800 (Multi Purpose Interface Module)IOB800 (Input/Output Expansion Board)FB800 (Fuse Board)

MX1000 1 loop Analogue Addressable Control and Indicating Equipment 018g/01Note:1. The following product variants are approved -Finished goods No. 557.200.001, MX1000 1 loop CIE, shallow housingFinished goods No. 557.200.005, MX-BBX battery box, shallow housingFinished goods No. 557.200.002, MX1000 1 loop CIE, deep housingFinished goods No. 557.200.019, MX-BBX-F battery box, flush housing

Incorporating as modular units:

OCM800 Operator Control ModuleODM800 Operator Display ModuleCPU800 Main CPU moduleFIM801 Field Interface Module PSU830 Power Supply Module

and as optional modular units:

ANN840 40 + 40 LED Annunciator moduleANN880 80 LED Annunciator moduleCOM820 20 way Status Command Module MPM800 Multi Purpose Interface Module IOB800 Input/Output Expansion BoardFB800 Fuse Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)

Page 123: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 113

Certificated Products LPCB Ref. No.

7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

MXR Repeater panel is approved for use with the MX1000 Control and Indicating Equipment (LPCB Reference 018f/R01):

Note:1. The following product variants are approved -Finished goods No. 557.200.013, MXR-PSU repeaterFinished goods No. 557.200.018, MXR-PSU-F repeater flush housingFinished goods No. 557.200.012, MXR repeaterFinished goods No. 557.200.017, MXR-F repeater flush housing

Incorporating as modular units:

OCM800 (Operator Control Module)ODM800 (Operator Display Module)PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)ANN880 (80 LED Annunciator)MPM800 (Multi Purpose Interface Module)IOB800 (Input/Output Expansion Board)FB800 (Fuse Board)

MX2 1-8 loop Analogue Addressable Control and Indicating Equipment 018h/01Notes:1. The following product variants are approved -Finished goods No. 557.200.203, MX2-210 1-4 loop CIE, shallow housingFinished goods No. 557.200.205, MX2-211, 1-8 loop CIE, deep housing

Incorporating as modular units:

DCM800 Operator Control / Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module drives 1 or 2 loopsPSU830 Power Supply Module

and as optional modular units:

XLM800 Expansion Loop Module drives 1 or 2 additional loopsANN881 80 LED Annunciator moduleMPM800 Multi Purpose Interface Module FB800 Fuse Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Page 124: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

114 31 Dec 2012

Certificated Products LPCB Ref. No.

11 Standardized input/output interface

MXR Repeater panel is approved for use with the MX2 Control and Indicating Equipment (LPCB Reference 018f/R01):

Notes:1. The following product variants are approved -Finished goods No. 557.200.013, MXR-PSU repeaterFinished goods No. 557.200.018, MXR-PSU-F repeater flush housingFinished goods No. 557.200.012, MXR repeater Finished goods No. 557.200.017, MXR-F repeater flush housing

Incorporating as modular units:

OCM800 (Operator Control Module)ODM800 (Operator Display Module)PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)ANN880 (80 LED Annunciator)MPM800 (Multi Purpose Interface Module)IOB800 (Input/Output Expansion Board)FB800 (Fuse Board)

T2000 2-8 loop Analogue Addressable Control and Indicating Equipment 018j/01Notes:1. The following product variants are approved -Finished goods No. 557.200.600, T2000 2-8 loop CIE, stainless housingFinished goods No. 557.200.602, T2000-BB battery box, stainless housingFinished goods No. 557.200.610, T2000 2-8 loop CIE, mild steel housingFinished goods No. 557.200.605, T2000-BB battery box, mild steel housing

Incorporating as modular units:

OCM800 Operator Control ModuleODM800 Operator Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module drives 1 or 2 loopsPSU830 Power Supply Module

and as optional modular units:

XLM800 Expansion Loop Module drives 1 or 2 additional loopsANN840 40 + 40 LED Annunciator moduleANN880 80 LED Annunciator moduleCOM820 20 way Status Command Module MPM800 Multi Purpose Interface Module IOB800 Input/Output Expansion BoardFB800 Fuse Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

T2000R Repeater panel is approved for use with the T2000CV Control and Indicating Equipment (LPCB Reference 018j/R01):

Page 125: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 115

Certificated Products LPCB Ref. No.

Notes1. The following product variants are approved -Finished goods No. 557.200.601, T2000R (AC) repeater stainless housingFinished goods No. 557.200.604, T2000R (DC) repeater stainless housingFinished goods No. 557.200.611, T2000R (AC) repeater mild steel housingFinished goods No. 557.200.612, T2000R (DC) repeater mild steel housing

Incorporating as modular units:

OCM800 (Operator Control Module)ODM800 (Operator Display Module)PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)ANN880 (80 LED Annunciator)MPM800 (Multi Purpose Interface Module)IOB800 (Input/Output Expansion Board)FB800 (Fuse Board)

T2000R Repeater panel is approved for use with the T2000 Control and Indicating Equipment: 018j/R01Notes:1. The following product variants are approved -Finished goods No. 557.200.601, T2000R (AC) repeater stainless housingFinished goods No. 557.200.604, T2000R (DC) repeater stainless housingFinished goods No. 557.200.611, T2000R (AC) repeater mild steel housingFinished goods No. 557.200.612, T2000R (DC) repeater mild steel housing

Incorporating as modular units:

OCM800 (Operator Control Module)ODM800 (Operator Display Module)PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)ANN880 (80 LED Annunciator)MPM800 (Multi Purpose Interface Module)IOB800 (Input/Output Expansion Board)FB800 (Fuse Board)

T2000CV 3 loop Analogue Addressable Control and Indicating Equipment 018k/01Notes:1. The following product variants are approved -Finished goods No. 557.200.620, T2000CV 3 loop CIEFinished goods No. 557.200.605, T2000-BB battery box

Incorporating as modular units:

OCM800 Operator Control ModuleODM800 Operator Display ModuleCPU800 Main CPU moduleXLM800 Expansion Loop Module “drives 1 or 2 additional loops”FIM802 Field Interface Module “drives 1 or 2 loops”PSU830 Power Supply Module

and as optional modular units:

ANN840 40 + 40 LED Annunciator moduleANN880 80 LED Annunciator moduleCOM820 20 way Status Command Module MPM800 Multi Purpose Interface Module IOB800 Input/Output Expansion BoardFB800 Fuse Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)

Page 126: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

116 31 Dec 2012

Certificated Products LPCB Ref. No.

7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

T2000R Repeater panel is approved for use with the T2000CV Control and Indicating Equipment (LPCB Reference 018j/R01):

Notes:1) The following product variants are approved -

Finished goods No. 557.200.601, T2000R (AC) repeater stainless housingFinished goods No. 557.200.604, T2000R (DC) repeater stainless housingFinished goods No. 557.200.611, T2000R (AC) repeater mild steel housingFinished goods No. 557.200.612, T2000R (DC) repeater mild steel housing

Incorporating as modular units:

OCM800 (Operator Control Module)ODM800 (Operator Display Module)PSU830 (Power Supply Module)

and as optional modular units:

ANN840 (40 + 40 LED Annunciator)ANN880 (80 LED Annunciator)MPM800 (Multi Purpose Interface Module)IOB800 (Input/Output Expansion Board)FB800 (Fuse Board)

MZX-125 Analogue Addressable Control and Indicating Equipment 1 loop, 16 Zone

Incorporating as modular units:

DCM816 Operator Control / Display ModuleCPU800 Main CPU moduleFIM801 Field Interface Module PMM800 Power Supply MonitorBAQ60T24 Power Supply

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

018m/01

MZX-250 Analogue Addressable Control and Indicating Equipment 1 loop, 32 Zone

Incorporating as modular units:

DCM832 Operator Control / Display ModuleCPU800 Main CPU module

018m/02

Page 127: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 117

Certificated Products LPCB Ref. No.

FIM802 Field Interface Module (1 loop version Part No. 2605053) PMM800 Power Supply MonitorBAQ140T24 Power Supply

and as an optional modular unit:

IOB800 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

MZX-251 Analogue Addressable Control and Indicating Equipment1 loop, 32 Zone

Incorporating as modular units:

DCM832 Operator Control / Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module (1 loop version Part No. 2605053)PMM800 Power Supply MonitorBAQ140T24 Power Supply

and as an optional modular unit:

IOB800 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

018m/03

MZX-250-CH Analogue Addressable Control and Indicating Equipment1 loop, 32 Zone

Incorporating as modular units:

DCM832 Operator Control / Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module (1 loop version Part No. 2605053)PMM800 Power Supply MonitorFBF-CH Swiss Fire Brigade InterfaceBAQ140T24 Power Supply

and as an optional modular unit:

018m/04

Page 128: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

118 31 Dec 2012

Certificated Products LPCB Ref. No.

IOB800 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

MZX-251-S Analogue Addressable Control and Indicating Equipment1 loop, 32 Zone

Incorporating as modular units:

DCM832 -S Operator Control / Display Module (ScandinavianFire Brigade Interface/key)CPU800 Main CPU moduleFIM802 Field Interface Module (1 loop version Part No. 2605053)PMM800 Power Supply MonitorBAQ140T24 Power Supply

and as an optional modular unit:

IOB800 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

018m/05

MZX-252 Analogue Addressable Control and Indicating Equipment2 loop, 32 Zone

Incorporating as modular units:

DCM832 Operator Control / Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply MonitorBAQ140T24 Power Supply

and as an optional modular unit:

IOB800 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices

018m/06

Page 129: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 119

Certificated Products LPCB Ref. No.

7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

MZX-252-CH Analogue Addressable Control and Indicating Equipment2 loop, 32 Zone

Incorporating as modular units:

DCM832 Operator Control / Display Module CPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply MonitorFBF-CH Swiss Fire Brigade InterfaceBAQ140T24 Power Supply

and as an optional modular unit:

IOB800 Input/Output Expansion Board

Certified with the following options with requirements from EN 54 Part 2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

018m/07

MZX-253 Analogue Addressable Control and Indicating Equipment2-4 loop, 64 ZoneIncorporating as modular units:

DCM864R Operator Control / Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply MonitorBAQ140T24 Power Supply

and as optional modular units:IOB800 Input/Output Expansion BoardPMM840 Power Supply MonitorXLM800 Loop Expander Board

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)

018m/08

Page 130: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

120 31 Dec 2012

Certificated Products LPCB Ref. No.

7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

MZX-254 Analogue Addressable Control and Indicating Equipment2-4 loop, 240 ZoneIncorporating as modular units:

DCM832 Operator Control / Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply MonitorBAQ140T24 Power Supply

and as optional modular units:IOB800 Input/Output Expansion BoardPMM840 Power Supply MonitorXLM800 Loop Expander Board

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C) 7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment 9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

018m/09

MZX-254-S Analogue Addressable Control and Indicating Equipment2-4 loop, 240 ZoneIncorporating as modular units:

DCM832-S Operator Control / Display Module (Scandinavian Fire Brigade Interface/key)CPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply MonitorBAQ140T24 Power Supply

and as optional modular units:IOB800 Input/Output Expansion BoardPMM840 Power Supply MonitorXLM800 Loop Expander Board

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)

018m/10

Page 131: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 121

Certificated Products LPCB Ref. No.

7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

MZX-254-CH Analogue Addressable Control and Indicating Equipment2-4 loop, 240 ZoneIncorporating as modular units:

DCM832 Operator Control / Display ModuleCPU800 Main CPU moduleFIM802 Field Interface Module PMM800 Power Supply MonitorFBF-CH Swiss Fire Brigade Interface BAQ140T24 Power Supply

and as optional modular units:IOB800 Input/Output Expansion BoardPMM840 Power Supply MonitorXLM800 Loop Expander Board

Certified with the following options with requirements from EN 54-2:7.8 Output to fire alarm devices7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10.1 Outputs to fire protection equipment (Type A)7.10.2 Outputs to fire protection equipment (Type B)7.10.3 Outputs to fire protection equipment (Type C)7.10.4 Fault monitoring of fire protection equipment 7.11 Delays to outputs7.12.1 Dependencies on more than one alarm signal (Type A dependency)7.12.2 Dependencies on more than one alarm signal (Type B dependency)7.12.3 Dependencies on more than one alarm signal (Type C dependency)7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition11 Standardized input/output interface

018m/11

MZX-16-R 16 Zone Repeater Panel, is approved for use with the MZX-125 Control and Indicating Equipment

Incorporating as modular units:

DCM816 Operator Control / Display ModulePMM800 Power Supply MonitorBAQ60T24 Power Supply

018m/R01

MZX-32-R 32 Zone Repeater Panel, is approved for use with the MZX-250, MZX-250-CH, MZX-251, MZX-252 & MZX-252-CH Control and Indicating Equipment

Incorporating as modular units:

DCM832 Operator Control / Display ModulePMM800 Power Supply MonitorBAQ60T24 Power Supply

018m/R02

MZX-32-SR 32 Zone Repeater Panel, is approved for use with the MZX-251-S Control and Indicating Equipment

Incorporating as modular units:

DCM832-S Operator Control / Display ModulePMM800 Power Supply MonitorBAQ60T24 Power Supply

018m/R03

MZX-64-DR 64 Zone Repeater Panel, is approved for use with the MZX-253 Control and Indicating Equipment

Incorporating as modular units:DCM832R Operator Control / Display ModulePMM805 Power Supply Monitor (24 VDC)

018m/R04

MZX-DR 240 Zone Repeater Panel, is approved for use with the MZX-254 Control and Indicating Equipment

018m/R05

Page 132: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

122 31 Dec 2012

Certificated Products LPCB Ref. No.

Incorporating as modular units:DCM832 Operator Control / Display ModulePMM805 Power Supply Monitor (24 VDC)

MZX-SDR 240 Zone Repeater Panel, is approved for use with the MZX254-S Control and Indicating Equipment

Incorporating as modular units:DCM832 -S Operator Control / Display Module (Scandinavian Fire Brigade Interface/key)PMM805 Power Supply Monitor (24 VDC)

018m/R06

MZX-CHDR 240 Zone Repeater Panel, is approved for use with the MZX-254-CH Control and Indicating Equipment

Incorporating as modular units:DCM832 Operator Control / Display ModuleFBF-CH Swiss Fire Brigade InterfacePMM805 Power Supply Monitor (24 VDC)

018m/R07

PSU A17 Addressable 17Ah Power Supply Unit 018n/02Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels2. The maximum lead length for the fault output connection is 3m

PSU A38 Addressable 38Ah Power Supply Unit 018n/03Notes: 1. The unit is not intended to supply power to Fire Alarm Control Panels2. The maximum lead length for the fault output connection is 3m

508.031.005.xx MZXC 4 zone conventional control and indicating equipment.

Incorporating as modular units: C1694 - 2605503, 4 Zone Motherboard BAQ-35T24 Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

Note: xx indicates the language option Blank = Blank facia overlay

018q/03

508.031.006.xx MZXC 8 zone conventional control and indicating equipment.

Incorporating as modular units: C1694 - 2605504, 8 Zone Motherboard BAQ-35T24 Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

Note: xx indicates the language option Blank = Blank facia overlay

018q/04

508.031.016.xx Fire alarm repeater (mains).

Incorporating as modular units: C1694 2605505, Repeater Motherboard BAQ-35T24 Power Supply

018q/R01

Notes: 1. Compatible with 508.031.005.xx & 508.031.006.xx panels.2. Also compatible with 508.031.005.xx & 508.031.006.xx twin wire conventional panels on certificate 018r.3. xx indicates the language option

Blank = Blank facia overlay EG = English facia overlay

508.031.004.xx MZXC 2 zone, twin wire conventional control and indicating equipment.

Incorporating as modular units: C1694 - 2605508, 2 Zone Twin Wire Motherboard

018r/01

Page 133: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 123

Certificated Products LPCB Ref. No.

BAQ-35T24, Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

Note: xx indicates the language option EG = English facia overlay

508.031.005.xx MZXC 4 zone, twin wire conventional control and indicating equipment.

Incorporating as modular units: C1694 - 2605509, 4 Zone Twin Wire Motherboard BAQ-35T24, Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

Note: xx indicates the language option EG = English facia overlay

018r/02

508.031.006.xx MZXC 8 zone twin wire conventional control and indicating equipment.

Incorporating as modular units: C1694 - 2605510, 8 Zone Twin Wire Motherboard BAQ-35T24 Power Supply

Certified with the following options with requirements from EN 54-2: 7.8 Output to fire alarm devices 7.9.1 Output to fire alarm routing equipment 7.12.1 Dependencies on more than one alarm signal - Type A 7.13 Alarm counter 10 Test condition

Note: xx indicates the language option EG = English facia overlay

018r/03

UTC Fire & Security (Africa) trading as ZitonZiton House, 555 Voortrekker Road, Maitland 7405, Cape Town, South AfricaTel: +27 21 5066000 • Fax: +27 21 5066100Website: www.utcfireandsecurity.com

UK Sales Enquiries:Tel: +44 (0)1908 281981 • Fax: +44 (0)1908 282554

Certificate No: 092h to BS EN 54-2: 1998 and BS EN 54-4: 1998 N.B. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because control and indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU.

Certificated Products LPCB Ref. No.

ZP3 1, 2 and 4 loop analogue addressable control and indicating equipmentIncorporating as modular units:

ZP3-MB2-4L 4 Loop Main boardZP3-MB2-2L 2 Loop Main boardZP3-MB2-1L 1 Loop Main boardZP3-CPU1 CPU board

092h/01

Page 134: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

124 31 Dec 2012

Certificated Products LPCB Ref. No.

ZP3-DB1 Display boardZP3-ZB50 50 Zone LED boardZP3-CB1 Commissioning key switch boardZP3-PR1 Printer KitZP3AB-SCB-D Control bus driveZP3AB-RL8 Programmable relay output board, 8 wayZP3-AB-MA8 Programmable monitored output board, 8 wayZP3AB-OP24 Programmable transistor output board, 24 wayZP3AB-MIP8 Programmable input board, 8 wayZP3-xL 230V ac Power supply unitApproved with the following options from EN54-2:7.8 Output to fire alarm devices7.9 Output to fire alarm routing equipment7.10 Output to fire protection equipment7.11 Delays to outputs7.12 Co-incidence detection7.13 Alarm counter8.3 Fault signals from points8.9 Output to fault routing equipment9.5 Disablement of addressable points10.0 Test condition11.0 Standardised input/output interface

UTC Fire & Security (Pty) LTD Trading as ZitonZiton House, 555 Voortrekker Road, Maitland 7405, South AfricaTel: +27 21 5066000 • Fax: +27 21 5066100Website: www.ziton.com

Certificate No: 092h to BS EN 54 - 2: 1998 and BS EN 54- 4: 1998 N.B. This certificate is to a withdrawn standard. Control and indicating equipment conforming to this standard is not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because controland indicating equipment meeting the withdrawn standard is still requested by some regulators outside of the EU.

Certificated Products LPCB Ref. No.

ZP3 (Traditional Chinese Language Variant)

1, 2 and 4 loop analogue addressable control and indicating equipment

Incorporating as modular units:

ZP3-MB2-4L 4 Loop Main board ZP3-MB2-2L 2 Loop Main board ZP3-MB2-1L 1 Loop Main board ZP3-CPU1 CPU board ZP3-DB1 Display board ZP3-ZB50 50 Zone LED board ZP3-CB1 Commissioning key switch board ZP3-PR1 Printer Kit ZP3AB-SCB-D Control bus driver ZP3AB-RL8 Programmable relay output board, 8 way ZP3-AB-MA8 Programmable monitored output board, 8 way ZP3AB-OP24 Programmable transistor output board, 24 way ZP3AB-MIP8 Programmable input board, 8 way ZP3-Xl 230Vac Power supply unit

Approved with the following options from BS EN54 Part 2:

7.8 Output to fire alarm devices7.9 Output to fire alarm routing equipment7.10 Output to fire protection equipment7.11 Delays to outputs7.12 Co-incidence detection7.13 Alarm counter8.3 Fault signals from points8.4 Total loss of power8.9 Output to fault routing equipment9.5 Disablement of addressable points

092h/01

Page 135: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 125

Certificated Products LPCB Ref. No.

10 Test condition11 Standardised input/output interface

UTC Fire & Security BVKelvinstraat 7, NL-6003DH, Weert, The NetherlandsTel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com

Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

SG2000 Conventional two zone control and indicating equipment

Incorporating the following units:1X-F2-MB Main control board2010-1-RB Optional relay board2010-1-SB Optional expander I/O board2010-1-NB Optional Network board2010-PS-20 2A Power Supply2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs8.4 Total loss of the power supply10 Test condition

1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits:01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International)

092v/01

SG2000SC Conventional two zone control and indicating equipment with Scandinavian key switch

Incorporating the following units:1X-F2-MB Main control board2010-1-RB Optional relay board2010-1-SB Optional expander I/O board2010-1-NB Optional Network board2010-PS-20 2A Power Supply2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs8.4 Total loss of the power supply10 Test condition

1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits:01 - Dutch, 02 -French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 - Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 - Arabic, 18 - Polish, 19 -Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27-Lithuanian, 28 - Finish, 30 - Estonian, 31 - Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 - Catalan, 99 - English (International)

092v/01

SG4000 Conventional four zone control and indicating equipment 092v/02

Page 136: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

126 31 Dec 2012

Certificated Products LPCB Ref. No.

Incorporating the following units:1X-F4-MB Main control board2010-1-RB Optional relay board2010-1-SB Optional expander I/O board2010-1-NB Optional Network board2010-PS-20 2A Power Supply2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delays to outputs8.4 Total loss of the power supply10 Test condition

1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits:01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International)

SG4000SC Conventional four zone control and indicating equipment with Scandinavian key switch

Incorporating the following units:1X-F4-MB Main control board2010-1-RB Optional relay board2010-1-SB Optional expander I/O board2010-1-NB Optional Network board2010-PS-20 2A Power Supply2010-SK Scandinavian Key Lock and Key (Applicable to SC variant)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delays to outputs8.4 Total loss of the power supply10 Test condition

1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits:01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International)

092v/02

SG8000 Conventional eight zone control and indicating equipment

Incorporating the following units:1X-F8-MB Main control board2010-1-RB Optional relay board2010-1-SB Optional expander I/O board2010-1-NB Optional Network board2010-PS-40 4A Power Supply2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment

092v/03

Page 137: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 127

Certificated Products LPCB Ref. No.

7.11 Delays to outputs8.4 Total loss of the power supply10 Test condition

1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits:01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International)

SG8000SC Conventional eight zone control and indicating equipment with Scandinavian key switch

Incorporating the following units:1X-F8-MB Main control board2010-1-RB Optional relay board2010-1-SB Optional expander I/O board2010-1-NB Optional Network board2010-PS-40 4A Power Supply2010-SK Scandinavian Key Lock and Key ( Applicable to SC variant)

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.11 Delays to outputs8.4 Total loss of the power supply10 Test condition

1) This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13. 2) Scope of approval does not include the operation of the network functionality. 3) Available with the following language kits:01 Dutch, 02 -French, 03 - English (UK), 04 German, 05 Norwegian, 06 Swedish, 07 Danish, 09 Spanish, 10 Italian,11 Belgian, Dutch, 15 Arabic, 18 Polish, 19 Turkish, 20 Czech, 21 Portuguese, 22 Hungarian, 24 Slovakian, 25 Russian, 27- Lithuanian, 28 Finish, 30 Estonian, 31 Latvian, 32 - Belgian French, 36 - French International, 45 Romanian, 71 Catalan, 99 - English (International)

092v/03

2X-F1 1 Loop intelligent analogue addressable control and indicating equipment

Incorporating the following units:2010-2-F1-MB Main control board2X-UI User interface control board2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB 2-Loop Node Card2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

092v/05

Page 138: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

128 31 Dec 2012

Certificated Products LPCB Ref. No.

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

2X-F1-FB 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output

Incorporating the following units:2010-2-F1-MB Main control board2X-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-232-IB Interface Board for External Printer2010-2-LB Loop expansion board2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Type A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/05

2X-F1-SC 1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch

Incorporating the following units:2010-2-F1-MB Main control board2X-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

092v/05

Page 139: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 129

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Type A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

2X-F2 2 Loop intelligent analogue addressable control and indicating equipment

Incorporating the following units:2010-2-F2-MB Main control board2X-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available in the following language variants:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/06

2X-F2-FB 2 Loop intelligent analogue addressable control and indicating equipment

Incorporating the following units:2010-2-F2-MB Main control board2X-UI User interface control board 2010-2-PS-40 4A Power Supply

092v/06

Page 140: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

130 31 Dec 2012

Certificated Products LPCB Ref. No.

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available in the following language variants:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

2X-F2-SC 2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch

Incorporating the following units:2010-2-F2-MB Main control board2X-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian,

092v/06

Page 141: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 131

Certificated Products LPCB Ref. No.

24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

2X-F1-S 1 Loop intelligent analogue addressable fire control panel in small cabinet

Incorporating the following units:2010-2-F1-MB Main control board2X-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/07

2X-F1-FB-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet

Incorporating the following units:2010-2-F1-MB Main control board2X-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/08

Page 142: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

132 31 Dec 2012

Certificated Products LPCB Ref. No.

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

2X-F1-SC-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet

Incorporating the following units:2010-2-F1-MB Main control board2X-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/09

2X-F2-S 2 Loop intelligent analogue addressable fire control panel in small cabinet

Incorporating the following units:2010-2-F2-MB Main control board2X-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

092v/10

Page 143: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 133

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

2X-F2-FB-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet

Incorporating the following units:2010-2-F2-MB Main control board2X-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/11

2X-F2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key

Incorporating the following units:2010-2-F2-MB Main control board

092v/12

Page 144: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

134 31 Dec 2012

Certificated Products LPCB Ref. No.

2X-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply2010-SK Scandinavian key and lock assembly

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

2X-FR Addressable Fire Panel Repeater

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R01

2X-FR-FB Addressable Fire Panel Repeater with Output to Fire Routing Equipment

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R02

2X-FR-S Addressable Fire Panel Repeater in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R03

2X-FR-SC Addressable Fire Panel Repeater with Scandinavian Key

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply

092v/R03

Page 145: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 135

Certificated Products LPCB Ref. No.

8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

2X-FR-SC-S Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R05

2X-FR-FB-S Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R06

Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Aritech - KFPCertificated Products LPCB Ref.

No.KFP-AF1 1 Loop intelligent analogue addressable control and indicating equipment

Incorporating the following units:2010-2-F1-MB Main control boardKFP-A-UI User interface control board2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB 2-Loop Node Card2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/05

Page 146: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

136 31 Dec 2012

Certificated Products LPCB Ref. No.

KFP-AF1-FB 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output

Incorporating the following units:2010-2-F1-MB Main control boardKFP-A-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-232-IB Interface Board for External Printer2010-2-LB Loop expansion board2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Type A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/05

KFP-AF1-SC 1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch

Incorporating the following units:2010-2-F1-MB Main control boardKFP-A-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Type A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C)7.13 Alarm counter8.4 Total loss of the power supply

092v/05

Page 147: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 137

Certificated Products LPCB Ref. No.

8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

KFP-AF2 2 Loop intelligent analogue addressable control and indicating equipment

Incorporating the following units:2010-2-F2-MB Main control boardKFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available in the following language variants:

01 – Dutch, 02 – French, 03 – English (UK), 04 – German, 05 – Norwegian, 06 – Swedish, 07 – Danish, 09 – Spanish, 10 – Italian,11 – Belgian, Dutch, 15 –Arabic, 18 – Polish, 19 – Turkish, 20 – Czech, 21 – Portuguese, 22 –Hungarian, 24 – Slovakian, 25 – Russian, 27- Lithuanian, 28 – Finish, 30 –Estonian, 31 – Latvian, 32 - Belgian French, 36 – French International, 45 –Romanian, 71 – Catalan, 99 - English (International)

092v/06

KFP-AF2-FB 2 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output

Incorporating the following units:2010-2-F2-MB Main control boardKFP-A-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

092v/06

Page 148: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

138 31 Dec 2012

Certificated Products LPCB Ref. No.

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 – Dutch, 02 – French, 03 – English (UK), 04 – German, 05 – Norwegian, 06 – Swedish, 07 – Danish, 09 – Spanish, 10 – Italian,11 – Belgian, Dutch, 15 –Arabic, 18 – Polish, 19 – Turkish, 20 – Czech, 21 – Portuguese, 22 –Hungarian, 24 – Slovakian, 25 – Russian, 27- Lithuanian, 28 – Finish, 30 –Estonian, 31 – Latvian, 32 - Belgian French, 36 – French International, 45 –Romanian, 71 – Catalan, 99 - English (International)

KFP-AF2-SC 2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch

Incorporating the following units:2010-2-F2-MB Main control boardKFP-A-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/06

Page 149: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 139

Certificated Products LPCB Ref. No.

KFP-AF1-S 1 Loop intelligent analogue addressable fire control panel in small cabinet

Incorporating the following units:2010-2-F1-MB Main control boardKFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/07

KFP-AF1-FB-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet

Incorporating the following units:2010-2-F1-MB Main control boardKFP-A-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection

092v/08

Page 150: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

140 31 Dec 2012

Certificated Products LPCB Ref. No.

and alarm systems requirements of EN 54-13. 2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

KFP-AF1-SC-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet

Incorporating the following units:2010-2-F1-MB Main control boardKFP-A-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/09

KFP-AF2-S 2 Loop intelligent analogue addressable fire control panel in small cabinet

Incorporating the following units:2010-2-F2-MB Main control boardKFP-A-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs

092v/10

Page 151: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 141

Certificated Products LPCB Ref. No.

7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

KFP-AF2-FB-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet

Incorporating the following units:2010-2-F2-MB Main control boardKFP-A-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/11

KFP-AF2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key

Incorporating the following units:2010-2-F2-MB Main control boardKFP-A-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply2010-SK Scandinavian key and lock assembly

092v/12

Page 152: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

142 31 Dec 2012

Certificated Products LPCB Ref. No.

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

KFP-AFR Addressable Fire Panel Repeater

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R01

KFP-AFR-FB Addressable Fire Panel Repeater with Output to Fire Routing Equipment

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R02

KFP-AFR-SC Addressable Fire Panel Repeater with Scandinavian Key

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R03

KFP-AFR-S Addressable Fire Panel Repeater in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R04

Page 153: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 143

Certificated Products LPCB Ref. No.

KFP-AFR-SC-S Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R05

KFP-AFR-FB-S Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R06

Certificate No: 092v-(cl-2) to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Ziton - ZP2Certificated Products LPCB Ref.

No.ZP2-F1 1 Loop intelligent analogue addressable control and indicating equipment

Incorporating the following units:2010-2-F1-MB Main control boardZP-UI User interface control board2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB 2-Loop Node Card2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/05

ZP2-F1-FB 1 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output

092v/05

Page 154: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

144 31 Dec 2012

Certificated Products LPCB Ref. No.

Incorporating the following units:2010-2-F1-MB Main control boardZP2-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-232-IB Interface Board for External Printer2010-2-LB Loop expansion board2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Type A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

ZP2-F1-SC 1 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch

Incorporating the following units:2010-2-F1-MB Main control boardZP2-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Type A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/05

Page 155: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 145

Certificated Products LPCB Ref. No.

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

ZP2-F2 2 Loop intelligent analogue addressable control and indicating equipment

Incorporating the following units:2010-2-F2-MB Main control boardZP-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Type A, B and C) 7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available in the following language variants:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/06

ZP2-F2-FB 2 Loop intelligent analogue addressable control and indicating equipment with fire alarm routing output

Incorporating the following units:2010-2-F2-MB Main control boardZP2-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

092v/06

Page 156: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

146 31 Dec 2012

Certificated Products LPCB Ref. No.

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

ZP2-F2-SC 2 Loop intelligent analogue addressable control and indicating equipment with Scandinavian key switch

Incorporating the following units:2010-2-F2-MB Main control boardZP2-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface Board for External Printer2X-ZI-20 20 zone LED indication board2X-ZI-40 40 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/06

ZP2-F1-S 1 Loop intelligent analogue addressable fire control panel in small cabinet

Incorporating the following units:2010-2-F1-MB Main control board

092v/07

Page 157: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 147

Certificated Products LPCB Ref. No.

ZP-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

ZP2-F1-FB-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet

Incorporating the following units:2010-2-F1-MB Main control boardZP2-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -

092v/08

Page 158: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

148 31 Dec 2012

Certificated Products LPCB Ref. No.

Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

ZP2-F1-SC-S 1 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key in small cabinet

Incorporating the following units:2010-2-F1-MB Main control boardZP2-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable2010-SK Scandinavian key and lock assembly

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/09

ZP2-F2-S 2 Loop intelligent analogue addressable fire control panel in small cabinet

Incorporating the following units:2010-2-F2-MB Main control boardZP-UI User interface control board 2010-2-PS-40 4A Power Supply

and as optional modules:2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points

092v/10

Page 159: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 149

Certificated Products LPCB Ref. No.

10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

ZP2-F2-FB-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output in small cabinet

Incorporating the following units:2010-2-F2-MB Main control boardZP2-UI-FB User interface control board with fire routing controls2010-2-PS-40 4A Power Supply

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment 7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

092v/11

ZP2-F2-SC-S 2 Loop intelligent analogue addressable fire control panel with fire alarm routing equipment output and Scandinavian key

Incorporating the following units:2010-2-F2-MB Main control boardZP2-UI-SC User interface control board with fire routing controls2010-2-PS-40 4A Power Supply2010-SK Scandinavian key and lock assembly

and as optional modules:

2010-2-NB Network board2010-2-LB Loop expansion board2010-2-232-IB Interface board for external printer

092v/12

Page 160: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

150 31 Dec 2012

Certificated Products LPCB Ref. No.

2X-ZI-24 24 zone LED indication board2010-2-PS-C2 UK mains cable

Certified with the following options with requirements from EN 54-2:

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.9.2 Alarm confirmation input from fire alarm routing equipment7.10 Output to fire protection equipment (Types A, B and C)7.11 Delays to outputs7.12 Dependencies on more than one alarm signal (Types A, B and C)7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

Notes:

1. This product approval does not constitute compliance with the fire detection and alarm systems requirements of EN 54-13.

2. Scope of approval does not include the operation of the network functionality.3. Available with the following language kits:

01 - Dutch, 02 - French, 03 - English (UK), 04 - German, 05 - Norwegian, 06 -Swedish, 07 - Danish, 09 - Spanish, 10 - Italian,11 - Belgian, Dutch, 15 -Arabic, 18 - Polish, 19 - Turkish, 20 - Czech, 21 - Portuguese, 22 - Hungarian, 24 - Slovakian, 25 - Russian, 27- Lithuanian, 28 - Finish, 30 - Estonian, 31 -Latvian, 32 - Belgian French, 36 - French International, 45 - Romanian, 71 -Catalan, 99 - English (International)

ZP2-FR Addressable Fire Panel Repeater

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R01

ZP2-FR-FB Addressable Fire Panel Repeater with Output to Fire Routing Equipment

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R02

ZP2-FR-SC Addressable Fire Panel Repeater with Scandinavian Key

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R03

ZP2-FR-S Addressable Fire Panel Repeater in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R04

ZP2-FR-SC-S Addressable Fire Panel Repeater with fire routing equipment output and Scandinavian key in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter

092v/R05

Page 161: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 151

Certificated Products LPCB Ref. No.

8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

ZP2-FR-FB-S Addressable Fire Panel Repeater with fire alarm routing equipment output in small cabinet

Incorporating the following options with requirements from EN 54-2:

7.13 Alarm counter8.4 Total loss of the power supply8.9 Output to fault warning routing equipment9.5 Disablement of addressable points10 Test condition

092v/R06

UTC Fire & Security Inc. Trading as Edwards Systems Technology8985 Town Center Parkway, Bradenton, Florida FL34202, USATel: 941 739-42228Website: www.fs.utc.com

Certificate No: 262z-(cl-2) to EN 54-2: 1997 + A1: 2006 and EN 54-4: 1997 + A1: 2002 + A2: 2006.

Control and indicating equipmentCertificated Products LPCB Ref.

No.EST3 control and indicating equipment

Incorporating as modular units:

3-SSDC1-E Signature (Single), driver controller module 3-SDDC1-E Signature (Dual), driver controller module 3-AADC1-E System Sensor driver control module 3-EASC-E Edwards (Single) Analogue driver controller module 3-EADC-E Edwards (Dual) Analogue driver controller module 3-PPS/M-230-E Primary Power Supply 3-BPS/M-230-E Booster Power Supply 3-BBC/M-230-E Booster Battery Charger Power Supply 3-CPU3 Central Processor Unit EFM-2 Data Communications Filter 3-CAB7-E 7 Slot Cabinet 3-CAB14-E 14 Slot Cabinet 3-CAB21-E 21 Slot Cabinet

3-CAB7D(R)-E Door for 7 Slot Cabinet, (R) indicates red 3-CAB14D(R)-E Door for 14 Slot Cabinet, (R) indicates red 3-CAB21D(R)-E Door for 21 Slot Cabinet, (R) indicates red 3-RCC7R-E Small Remote Battery Cabinet 3-RCC14R-E Medium Remote Battery Cabinet 3-RCC21R-E Large Remote Battery Cabinet 3-LCD Liquid Crystal Display, user interface 3-BATSEN-E Remote battery cabinet interface, temperature sensing 3-BATSEN Remote battery cabinet interface 3-BATS Battery Shelf 3-RS485A Data Communication, Class A 3-RS485B Data Communication, Class B 3-RS232 Serial Communications Card (Printer, etc) 3-PSMON Primary Power Supply Monitor 3-IDC8/4 Initiating Device Circuits/NACS 3-24R 24, Red 3-24Y 24, Yellow 3-24G 24, Green 3-12RY Red-over-yellow pairs 3-12SR 12 Switches. Red 3-12SY 12 Switches. Yellow 3-12SG 12 Switches. Green 3-12/S1GY 12 Switches. Green over-yellow pairs 3-12/S1RY 12 Switches. Red over-yellow pairs

262z/01

Page 162: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

152 31 Dec 2012

Certificated Products LPCB Ref. No.

3-12/S2Y 24, Yellow, 12 Switches 3-12/S2R 24, Red, 12 Switches 3-6/3S1G2Y Green-over-yellow-over-yellow triads, 6 triads 3-6/3S1GYR Green-over-yellow-over-red triads, 6 triads 3-6/3S2RY Red-over-yellow-over-red triads, 6 triads 3-BBCMON Booster, Battery Charger Monitor 3-BPSMON Booster Power supply Monitor 3-LDSM Annunciator strip support module 3-LRMF Local Rail Module Filler 3-RCIC ASU Interconnect power and rail communication unit

Certified with the following options with requirements from EN 54 Part 2:

7.8 Output to fire alarm devices 7.13 Alarm counter 8.3 Fault Signals from points 10 Test condition

EST3 Repeater Incorporating as modular units:

3-RS485BA Remote Annunciator RS485 Communications. 3-ANNCPU3 Remote Annunciator CPU 3-LCDANN-E LCD Display and User Interface for Remote Annunciator 3-ANNSM Remote (repeater) Annunciator Support Module 3-REMICA Remote paging Microphone. 3-24Y 24, Yellow. 3-12/S1GY 12 Switches. Green over-yellow pairs. 3-4ANN-E(R) Remote Annunciator Back Box, 4 slots, with Door (R)

indicates red 3-6ANN-E(R) Remote Annunciator Back Box, 6 slots, with Door (R)

indicates red 3-10ANN-E(R) Remote Annunciator Back Box, 10 slots, with Door (R)

indicates red

262z/01R

Xtralis Pty Limited4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, AustraliaTel: +61 3 9936 7001, +44 (0)1442 242330 • Fax: +61 3 9936 7201E-mail: [email protected] • Website: www.xtralis.com

Certificate No: 305f to EN 54-4: 1997 + A1: 2002 + A2: 2006

Power Supply UnitCertificated Products LPCB Ref.

No.VPS-215-U Power Supply Unit 305f/01

Note: The unit is not intended to supply power to Fire Alarm Control Panels

VPS-220-U Power Supply Unit 305f/02Note: The unit is not intended to supply power to Fire Alarm Control Panels

516-018-407 Power Supply Unit 305f/03Note: The unit is not intended to supply power to Fire Alarm Control Panels

Page 163: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 153

Zarja Elektronika d.o.oPolceva, Pot 1, 1240 Kamnik, SloveniaTel: +386 1831 7488 • Fax: +386 1831 7551E-mail: [email protected] • Website: www.zarja.com

Certificate No: 1124a to EN54-2: 1997 + A1: 2006 and EN54-4: 1997 + A1: 2002 + A2: 2006

Control and indicating equipmentCertificated Products LPCB Ref.

No.NJP-400A Analogue addressable and Conventional control and indicating equipment.

Incorporating the following units:

UPMO 400 Control and display moduleNAMO 400 Power supply moduleCPMO 400 Central processor module

Optional modules:

LIMO-Ap 400 Line module ApolloLIMO-Ko 400 Line module conventionalVIMO 400 Input output moduleIZMO 400 Output moduleMRMO 400 Network moduleEng_pack English language kit Slo_pack Slovenian language kit

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.10.1 Output to fire protection equipment type A7.10.2 Output to fire protection equipment type B7.11 Delays to the auctioning of outputs 8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

Notes:1) Scope of approval does not include the operation of the network functionality.2) This product approval does not constitute compliance with the fire detection and alarm

systems requirements of EN54-13.

1124a/01

NJP-401A Analogue addressable and Conventional control and indicating equipment.

Incorporating the following units:

UPMO 400 Control and display module NAMO 401 Power supply module CPMO 400 Central processor module

Optional modules:

LIMO-Ap 400 Line module ApolloLIMO-Ko 400 Line module conventionalVIMO 400 Input output moduleIZMO 400 Output moduleMRMO 400 Network moduleEng_pack English language kit Slo_pack Slovenian language kit

Certified with the following options with requirements from EN 54-2:1997

7.8 Output to fire alarm device(s)7.9.1 Output to fire alarm routing equipment7.10.1 Output to fire protection equipment type A

1124a/02

Page 164: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

154 31 Dec 2012

Certificated Products LPCB Ref. No.

7.10.2 Output to fire protection equipment type B7.11 Delays to the auctioning of outputs 8.3 Fault signals from points 9.5 Disablement of each address point10 Test condition

Notes:1) Scope of approval does not include the operation of the network functionality.2) This product approval does not constitute compliance with the fire detection and alarm

systems requirements of EN54-13.

Zeta Alarm Systems by GLT Exports LimitedDetection House, 72-78 Morfa Road, Swansea SA1 2EN, United KingdomTel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176E-mail: [email protected] • Website: www.gltexports.com

Certificate No: 330d to EN 54: Part 2 and 4: 1997

Certificated Products LPCB Ref. No.

Premier SX 1 zone conventional control and indicating equipment 330d/01Premier SX 2 zone conventional control and indicating equipment 330d/02Premier SX 4 zone conventional control and indicating equipment 330d/03Premier SX 6 zone conventional control and indicating equipment 330d/04Premier SX 8 zone conventional control and indicating equipment 330d/05

Certified with the following options with requirements from EN 54: Part 2:7.8 Output to fire alarm devices7.11 Delays to the actioning of outputs10 Test condition

Premier MX 2 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

330d/06

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Premier MX 4 4 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

330d/07

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Premier MX 8 8 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

330d/08

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Page 165: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 3CONTROL AND INDICATING EQUIPMENT

31 Dec 2012 155

Certificated Products LPCB Ref. No.

Premier MX 16 16 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface (option)

330d/09

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Premier MX 32 32 zone conventional control and indicating equipmentIncorporating as modular units:

C1627 Mother board C1629 Display board C1632 16 Zone expansion board C1652 5A Power Supply board C1631 Repeater interface (option)

330d/10

Certified with the following options from EN 54: Part 27.8 Output to fire alarm devices7.9 Output to fire routing equipment7.10 Output to automatic fire protection equipment7.11 Delays to outputs8.9 Output to fault warning equipment10 Test condition

Premier MX Repeater 8 8 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface

330d/R01

Premier MX Repeater 16 16 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1628 Display board C1631 Repeater interface

330d/R02

Premier MX Repeater 32 32 zone conventional repeater unitIncorporating as modular units:

C1627 Mother board C1629 Display board C1631 Repeater interface

330d/R03

Certificate No: 018c to EN 54-2 and 4:1997

Certificated Products LPCB Ref. No.

Prem1er AL 4 loop analogue addressable control and indicating equipmentIncorporating:

A1579 Motherboard A1580 Display board A1585 Loop cards A1584 230V AC power supply control card A1599 Printer board

018c/01

Certified with the following options from EN 54-2: 19977.8 Output to fire alarm devices7.11 Delays to outputs8.3 Fault signals from points9.5 Disablement of addressable points10 Test condition

Page 166: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

156 31 Dec 2012

There are many types of detectors on the market designed to work on different principles and fire parameters (e.g. smoke, flame radiation, convective heat etc). The selection of a detector for a particular area or application should be based on a number of factors including the following:

The nature of the fire hazard The speed of response required The need to minimize false alarms

There are other factors to be taken into account such as architecture of the building, ease of maintenance and cost, etc.

Guidance on the selection of appropriate types of detectors should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). Where a particular type of detector is not covered by the installation rule or code of practice then guidance should be sought from the manufacturer’s literature. In any case, account should be given to the notes or limitations given with the listed detector in this section.

This section lists fire detectors approved for use in fire detection and fire alarm systems in buildings.

The initial approval and continued approval processes for detectors are outlined in scheme document SD021.

The list includes detectors certified to recognised standards or to special test schedules which are developed by LPCB for detector types where suitable standards are not available or were not available at the time of the evaluation.

Products listed in this section have been approved to: EN 54-5: 2000 Heat detectors - point detectors EN 54-5: 2000 + A1: 2002 Heat detectors - point detectors EN 54-7: 2000 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-7 :2000 +A1: 2002 and A2: 2006 Smoke detectors - point detectors using scattered light, transmitted light or ionisation EN 54-10: 2002 Flame detectors - point detectors EN 54-10: 2002 + A1: 2005 Flame detectors - point detectors EN 54-12: 2002 Smoke detectors - line detectors using an optical light beam EN 54-20: 2006 Aspirating smoke detectors EN 54-25: 2008 Components using radio links ISO7240-5: 2003 Point -type heat detectors ISO7240-6: 2004 Carbon monoxide fire detectors using electro-chemical cells ISO7240-7: 2003 Point-type smoke detectors using scattered light, transmitted light or ionization ISO7240-12: 2005 Line type smoke detectors using transmitting light beam ISO7240-15: 2004 Multisensor fire detectors ISO 7240-6: 2008 Carbon monoxide fire detectors using electro-chemical cells and heat sensors. CEA 4021: 1999 Requirements and test methods for multisensor detectors, which respond to smoke

and heat, and smoke detectors with more than one smoke sensor CEA 4021: 2003 Requirements and test methods for multisensor detectors, which respond to smoke

and heat, and smoke detectors with more than one smoke sensor LPS 1265-1.1: 2005 Requirements and Testing Procedures for the LPCB Approval and Listing of

Carbon Monoxide Fire Detectors Using Electrochemical Cells LPS 1274-1.0: 2005 Testing Procedures for the LPCB Approval and Listing of Carbon Monoxide

/Heat Multisensor Fire Detectors Using Electrochemical Cells LPS 1279-1.0: 2006 Testing Procedures for the LPCB Approval and Listing of Point Multisensor Fire

Detectors using Optical or Ionization Smoke Sensors and Electrochemical Cell CO Sensors and, optionally, Heat Sensors

LPS 1280-1.0: 2007 Testing Procedures for the LPCB Approval and Listing of Duct Smoke Detectors using Point Smoke Detectors

Page 167: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 157

Approval can also be obtained for other detection principles not detailed above. In such circumstances, LPCB can develop test criteria to evaluate products, which in time may be used for the development of standards.

Audit:Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard.

Notes:1. EN 54-5: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is

required for most of the European market since 30 June 2005. It is therefore recommended that heat detectors are certificated to EN 54-5: 2000 + A1: 2002

2. EN 54-7: 2000 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 June 2005. It is therefore recommended that smoke detectors are certificated to EN 54-7: 2000 + A1: 2002 and A2: 2006

3. EN 54-10: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 September 2008. It is therefore recommended that flame detectors are certificated to EN 54- 10: 2002 + A1: 2005

4. EN 54-12: 2002 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 31 December 2005. It is therefore recommended that beam detectors are certificated to EN 54- 12: 2002

5. EN 54-25: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 March 2011. It is therefore recommended that radio link components are certificated to EN 54- 25: 2008

6. CEA 4021: 2003 supersedes CEA 4021: 1999 which was withdrawn in June 2003 (i.e. at the same time as the national versions of EN 54-5: 1976 and EN 54-7: 1982 were officially withdrawn and replaced with EN 54- 5: 2000 and EN 54-7: 2000).

7. EN 54-20: 2006 supersedes CEA 4022: 1999 which should have been withdrawn in 2009.EN 54-20: 2006 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 July 2009. It is therefore recommended that aspirating detectors are certificated to EN 54-20: 2006.

8. The bases with which a detector has been evaluated and shown to meet the relevant standards are listed with each detector. Bases are not approved/certificated in their own right unless they are combined with another device (e.g. short circuit isolator or sounder).

9. Since LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

ADI InternationalADI International Espana, C/Vivero 5, 28040 Madrid, SpainTel: +34 91 102 590 • Fax: +34 91 535 0081E-mail: [email protected] • Website: www.ademco.es

Certificate No: 199u to EN 54-12: 2002

Beam DetectorsCertificated Products LPCB Ref.

No.8200R Conventional optical beam detector 199u/01

Note:

Page 168: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

158 31 Dec 2012

Certificated Products LPCB Ref. No.

1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate levels 1 & 2

8200RS Conventional optical beam detector with self test facility 199u/02Note:1. Meets the requirements for EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 & Acclimate levels 1 & 2

Advanced Electronics Limited34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United KingdomTel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222E-mail: [email protected] • Website: www.Advel.co.uk

Certificate No: 928a-(cl-5) to EN54-5: 2000 + A1: 2002 and EN 54 -17: 2005Certificate No: 928d-(cl-5) to EN 54-5: 2000 + A1: 2002Certificate No: 928j-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Point Heat DetectorsCertificated Products LPCB Ref.

No.20-V350-ADV Analogue addressable Class P heat detector with short circuit isolator (20-AB100-ADV

base)928a/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B.

20-LV350-ADV Analogue addressable Class P, temperature detector (20-VB100-ADV and 20-AB100-ADV bases)

928d/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B.

20-AS3500-ADV Conventional Class P, heat detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100-ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV)

928d/02

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B.

20-SG350-ADV Wireless heat detector (WAB100 base) 928j/01Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases20-AB100-ADV Mounting base20-VB100-ADV Mounting base (with link resistor)20-ABR100-ADV Universal adaptor base with resistor20-ABDR100-ADV Universal adaptor base with resistor and Schottky diode20-ABS100-ADV Deep adaptor base20-ABSR100-ADV Deep adaptor base with resistor20-ABSRD100-ADV Deep adaptor base with resistor and Schottky diodeWAB100 Wireless adaptor base

Certificate No: 928b-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005Certificate No: 928e-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.20-V100-ADV Analogue addressable photoelectric smoke detector with short circuit isolator (20-AB100-

ADV base)928b/01

Note:

Page 169: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 159

Certificated Products LPCB Ref. No.

1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

20-LV100-ADV Analogue addressable optical smoke detector (20-VB100-ADV and 20-AB100-ADV bases)

928e/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

20-AS1000-ADV Conventional photo smoke detector (20-AB100-ADV, 20-ABR100-ADV, 20-ABDR100-ADV, 20-ABS100-ADV, 20-ABSR100-ADV and 20-ABSRD100-ADV)

928e/02

Bases20-AB100-ADV Mounting base20-VB100-ADV Mounting base (with link resistor)20-ABR100-ADV Universal adaptor base with resistor20-ABDR100-ADV Universal adaptor base with resistor and Schottky diode20-ABS100-ADV Deep adaptor base20-ABSR100-ADV Deep adaptor base with resistor20-ABSRD100-ADV Deep adaptor base with resistor and Schottky diode

Certificate No: 928c-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003Certificate No: 928f-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-sensor detectorsCertificated Products LPCB Ref.

No.20-V200-ADV Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with

short circuit isolator (20-AB100-ADV base)928c/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 2 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 3 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3

Optical only level 4 - Low

20-LV200-ADV Analogue addressable photo thermal multisensor (20-VB100-ADV and 20-AB100-ADV bases)

928f/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 2 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 3 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response

Page 170: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

160 31 Dec 2012

Certificated Products LPCB Ref. No.

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3

Optical only level 4 - Low

Bases20-AB100-ADV Mounting base20-VB100-ADV Mounting base (with link resistor)

Certificate No: 928k-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.20-SG100-ADV Wireless optical smoke detector (WAB100 base) 928k/01

Notes:1. Meets the requirements of EN 54-7 in the normal sensitivity setting2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Certificate No: 928m-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.20-SG200-ADV Wireless multi-criteria detector (WAB100 base) 928m/01

Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity setting3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Advantronic Systems S.L.C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, SpainTel: +34 91 806 2343 • Fax: +34 91 803 1171E-mail: [email protected] • Website: www.advantronic.es

Certificate No: 928a-(cl-3) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005Certificate No: 928d-(cl-3) to EN 54-5: 2000 + A1: 2002Certificate No: 928j-(cl-2) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Point Heat DetectorsCertificated Products LPCB Ref.

No.AT120A Analogue addressable Class P heat detector with short circuit isolator (BA100 base) 928a/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B.

AT120AS Analogue addressable Class P, temperature detector (BA100 base) 928d/01

Page 171: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 161

Certificated Products LPCB Ref. No.

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B.

AT120CM Conventional Class P, heat detector (BA100 and BA101 bases) 928d/02Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B.

ATW120A Wireless heat detector (WAB100 base) 928j/01Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

BasesBA100 Mounting baseBA101 Deep adaptor baseWAB100 Wireless Adaptor Base

Certificate No: 928b-(cl-3) to 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005Certificate No: 928e-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.AT110A Analogue addressable photoelectric smoke detector with short circuit isolator (BA100

base)928b/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

AT110AS Analogue addressable optical smoke detector (BA100 base) 928e/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

AT110CM Conventional photo smoke detector (BA100 and BA101 bases) 928e/02

BasesBA100 Mounting baseBA101 Deep adaptor base

Certificate No: 928c-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003Certificate No: 928f-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-sensor DetectorsCertificated Products LPCB Ref.

No.AT130A Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with

short circuit isolator (BA100 base)928c/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 2 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 3 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

Page 172: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

162 31 Dec 2012

Certificated Products LPCB Ref. No.

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3

Optical only level 4 - Low

AT130AS Analogue addressable photo thermal multisensor (BA100 base) 928f/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 2 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 3 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3

Optical only level 4 - Low

BasesBA100 Mounting base

Certificate No: 928k-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.ATW110A Wireless optical smoke detector (WAB100 base) 928k/01

Notes:1. Meets the requirements of EN 54-7 in the normal sensitivity setting2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Certificate No: 928m-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.ATW130A Wireless multi-criteria detector (WAB100 base) 928m/01

Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity setting3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Page 173: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 163

AGNI Devices PVT LtdC-55 DSIDC Ind Complex, Tilak Vihar, Tilak Nagar, New Delhi 110018, IndiaTel: +91 11 28335624E-mail: [email protected]

Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.AD338-2L Conventional photoelectric smoke detector (AD300 base) 550a/05

AD300 Standard Base

Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.AD338-2HL Conventional photo-thermal class A1R detector (AD300 base) 550b/06

Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity

Base:AD300 standard base

Certificate No: 550c to EN54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.AD318-2L Conventional A1R rate of rise heat detector (AD300 base) 550c/08

Base:AD300 standard base

Aguilera Electronica S.LC / Julian Camarillo 26, Madrid 28037, SpainTel: +34 917545511 • Fax: +34 917545098E-mail: [email protected]

Certificate No: 512d-(cl-2) to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.AE/C5-TV Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector

with LED output (P/N854001 base)512d/04

Bases:P/N854001 4-Wire detector base

Certificate No: 512a-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.AE/C5-OP Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001

base)512a/02

Page 174: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

164 31 Dec 2012

Bases:P/N854001 4-Wire detector base

Certificate No: 512b-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2002 & CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.AE/C5-OPT Conventional 2 wire photoelectric smoke and heat detector with remote LED output

(P/N854001 base)512b/02

Bases:P/N854001 4 Wire detector base

Alarm Supply Pte Ltd63 Jalan Pemimpin, 03-07 Pemimpin Industrial Building, Singapore 577219, SingaporeTel: +65 625 83445 • Fax: +65 625 86428

Certificate No: 512a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.EA318-2 Conventional 2 wire photoelectric smoke detector (P/N852001 base) 512a/01EA318-2L Conventional 2 wire photoelectric smoke detector with remote LED output (E300-Base) 512a/02

Bases:E300-Base 4-wire detector baseP/N852001 2-wire detector base

Certificate No: 512d-(cl-1) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.EA323-2 Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector

(P/N852001 base)512d/02

EA323-2L/A2R Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (E300-Base)

512d/04

Bases:E300-Base 4-wire detector baseP/N852001 2-wire detector base

AMPAC Technologies PTY Ltd7 Ledgar Road, Balcatta 6021, AustraliaTel: +618 (9242) 3333 • Fax: +618 (9242) 3334E-mail: [email protected] • Website: www.ampac.net

Certificate No: 010ar to EN 54-5 : 2000 + A1: 2002Certificate No: 010p-(cl-2) to EN54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.55000-465AMP Analogue addressable Class A2S heat detector

(45681-505AMP mounting bases)010ar/01

55000-475AMP Analogue addressable Classheat detector(45681-505AMP mounting bases)

010ar/02

55000-122AMP Series 65 Conventional Class A1R heat detector - Standard (45681-200AMP mounting 010p/06

Page 175: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 165

Certificated Products LPCB Ref. No.

base) 1 Meets the requirements of EN54: Part 5 - Class A1R

55000-127AMP Series 65 Conventional Class BR heat detector - Standard (45681-200AMP mounting base) 1

Meets the requirements of EN54: Part 5 - Class BR

010p/09

55000-132AMP Series 65 Conventional Class CR heat detector - Standard (45681-200AMP mounting base) 1

Meets the requirements of EN54: Part 5 - Class CR

010p/12

55000-137AMP Series 65 Conventional Class CS heat detector - Standard (45681-200AMP mounting base) 1

Meets the requirements of EN54: Part 5 - Class CS

010p/15

Bases:

45681-505AMP Negative switching isolating base45681-200AMP Series 60/65 mounting base45681-201AMP Series 60/65 diode mounting base45681-245AMP Series 65 relay mounting base45681-246AMP Series 65 auxiliary relay mounting base45681-247AMP Series 65 EOL 12 Volt mounting base45681-248AMP Series 65 EOL 24 Volt mounting base

Notes: 1 Also certificated for use with 45681-245AMP, 45681-246AMP, 45681-247AMP, 45681-248AMP and 45681-201AMP mounting bases.

Certificate No: 010as to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 010q-(cl-2) to EN54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.55000-665AMP Analogue addressable optical smoke detector

(45681-505AMP mounting bases)010as/01

55000-217AMP Series 65 Conventional ionisation smoke detector - Standard (45681-200AMP mounting base) 1

010q/06

55000-220AMP Series 65 Conventional integrating ionisation smoke detector - Standard (45681-200AMP mounting base) 1

010q/09

55000-317AMP Series 65 Conventional optical smoke detector - Standard (45681-200AMP mounting base) 1

010q/12

Bases:

45681-505AMP Negative switching isolating base45681-200AMP Series 60/65 mounting base45681-201AMP Series 60/65 diode mounting base45681-245AMP Series 65 relay mounting base45681-246AMP Series 65 auxiliary relay mounting base45681-247AMP Series 65 EOL 12 Volt mounting base45681-248AMP Series 65 EOL 24 Volt mounting base

Notes: 1 Also certificated for use with 45681-245AMP, 45681-246AMP, 45681-247AMP, 45681-248AMP and 45681-201AMP mounting bases.

Certificate No: 010at to EN 54-17: 2005

Negative Switching Isolating BaseCertificated Products LPCB Ref.

No.45681-505AMP Negative switching isolating base 010at/01

Certificate No: 010m-(cl-1) to EN54-7: 2001 + A1: 2002 + A2: 2006 & CEA 4021: 2003Certificate No: 010aq-(cl-1) to EN 54-5: 2000 + A1: 2002 + LPS 1274: 2005 + LPS 1265: 2004

Page 176: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

166 31 Dec 2012

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.58000-305AMP Analogue addressable CO/heat multisensor detector

(45681-210AMP, standard intelligent mounting base)

Notes:1. Approved with the following mode configurations:-Mode 1 30 ppm with high thermal enhancement (most sensitive)Mode 2 33 ppm with CO onlyMode 3 40 ppm with low thermal enhancement (nominal sensitivity)

Mode 4 45 ppm with high thermal enhancement (least sensitive) Mode 5 heat onlyA1R

2. Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 20023. Mode 2 is approved to LPS 1265:20044. Mode 5 is approved to EN 54-5:2000 + A1:2002

Conditions of approval include;

a) The 58000-305AMP should only be installed in accordance with the manufacturers recommendations.b) The 58000-305AMP should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning/flaming fires.c) Refer to technical publication MAN3038-1 for limitations on the use of carbon monoxide fire detection.

010aq/01

55000-885AMP Analogue addressable multisensor detector (45681-209AMP and 45681-210AMP mounting base) 1

010m/01

Bases:45681-209AMP XP95/Discovery standard deep mounting base45681-210AMP XP95 mounting base45681-210AMP Standard intelligent mounting base

Note:1 Approved with Apollo XP95 and S90 digital communication protocols that have been configured for the XP95 multisensor detector in accordance with manufacturer’s instructions.

Page 177: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 167

Apollo Fire Detectors Limited36 Brookside Road, Havant, Hampshire PO9 1JR, United KingdomTel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754E-mail: [email protected]

Sales Enquiries Germany,Apollo Deutschland GmbHTel: +49 5241 330 60 • Fax: +49 5241 330 629E-mail: [email protected]

Sales Enquiries Spain,Apollo EspanaTel: +34 627 988 061 • Fax: +34 949 335 289E-mail: [email protected]

Sales Enquiries China,Apollo Fire Detectors Limited, Shanghai representative officeTel: +86 21 5237 0922 • Fax: +86 21 5237 0920E-mail: [email protected]

Certificate No: 010r to EN 54: Part 5: 2000Certificate No: 010ab to EN 54-5: 2000 + A1: 2002Certificate No: 010p to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.XPA-HT-11170-APO Xpander addressable radio linked Class A1R heat detector (XPA-WB-10022-APO

mounting base)010ab/01

Notes: 1) Meets the requirements of EN 54-5 for Class A1R.2) The complete radio base/detector combination is available as Apollo Part No.: XPA-

CB-11170-APO.3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells.4) The radio link functionality of this device is not included within the scope of approval.

XPA-HT-11171-APO Xpander addressable radio linked Class CS heat detector (XPA-WB-10022-APO mounting base)

010ab/02

Notes: 1) Meets the requirements of EN 54-5 for Class CS.2) The complete radio base/detector combination is available as Apollo Part No.: XPA-

CB-11171-APO.3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells.4) The radio link functionality of this device is not included within the scope of approval.

59000-400 XPlorer Analogue addressable Class A2S heat detector (45681-500 and 45681-501 mounting bases)

010p/01

Certificated with Apollo Series 90 and XP95 digital communication protocols59000-410 XPlorer Analogue addressable Class CS heat detector (45681-500 and 45681-501 mounting

bases)010p/02

Certificated with Apollo Series 90 and XP95 digital communication protocols58000-400 Discovery Analogue addressable heat detector (45681-209 and 45681-210 mounting base)2 010p/03

Note: Meets the requirements of EN 54: Part 5 for the following settingsClass A1R in mode 1 and in conventional mode.Class A2 in mode 2 and in conventional mode.Class A2S in mode 3 and in conventional mode.Class CR in mode 4 and in conventional mode.Class CS in mode 5 and in conventional mode.Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols when the Discovery heat detector has been configured in accordance with manufacturer's

Page 178: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

168 31 Dec 2012

Certificated Products LPCB Ref. No.

instructions.55000-120 Series 65 Conventional Class A1R heat detector - Flashing LED/Reed switch (45681-200 mounting

base)010p/04

Note: Meets the requirements of EN 54: Part 5 - Class A1RAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-121 Series 65 Conventional Class A1R heat detector - Flashing LED (45681-200 mounting base) 010p/05Note: Meets the requirements of EN 54: Part 5 - Class A1RAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-122 Series 65 Conventional Class A1R heat detector - Standard (45681-200 mounting base) 010p/06Note: Meets the requirements of EN 54: Part 5 - Class A1RAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-125 Series 65 Conventional Class BR heat detector - Flashing LED/Reed switch (45681-200 mounting base)

010p/07

Note: Meets the requirements of EN 54: Part 5 - Class BRAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-126 Series 65 Conventional Class BR heat detector - Flashing LED (45681-200 mounting base) 010p/08Note: Meets the requirements of EN 54: Part 5 - Class BRAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-127 Series 65 Conventional Class BR heat detector - Standard (45681-200 mounting base) 010p/09Note: Meets the requirements of EN 54: Part 5 - Class BRAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-130 Series 65 Conventional Class CR heat detector- Flashing LED/Reed switch (45681-200 mounting base)

010p/10

Note: Meets the requirements of EN 54: Part 5 - Class CRAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-131 Series 65 Conventional Class CR heat detector - Flashing LED (45681-200 mounting base) 010p/11Note: Meets the requirements of EN 54: Part 5 - Class CRAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-132 Series 65 Conventional Class CR heat detector - Standard (45681-200 mounting base) 010p/12Note: Meets the requirements of EN 54: Part 5 - Class CRAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-135 Series 65 Conventional Class CS heat detector - Flashing LED/Reed switch (45681-200 mounting base)

010p/13

Note: Meets the requirements of EN 54: Part 5 - Class CSAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-136 Series 65 Conventional Class CS heat detector - Flashing LED (45681-200 mounting base) 010p/14Note: Meets the requirements of EN 54: Part 5 - Class CSAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-137 Series 65 Conventional Class CS heat detector - Standard (45681-200 mounting base) 010p/15Note: Meets the requirements of EN 54: Part 5 - Class CSAlso Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-400 XP95 Analogue addressable Class A2S heat detector 45681-209 and 45681-210 mounting base)

010p/20

Certificated with Apollo Discovery, XP95, and S90 digital communications protocolsconfigured for the Discovery heat detector in accordance with manufacturers instructions.

55000-401 XP95 Analogue addressable Class CS heat detector 45681-209 and 45681-210 mounting base)

010p/21

Certificated with Apollo Discovery, XP95, and S90 digital communications protocolsconfigured for the Discovery heat detector in accordance with manufacturers instructions.

55000-420 XP95 Analogue addressable Class A2S heat detector 45681-209 and 45681-210 mounting base)

010p/22

Certificated with Apollo Discovery, XP95, and S90 digital communications protocolconfigured for the Discovery heat detector in accordance with manufacturers instructions.

55000-440 XP95 IS Analogue addressable intrinsically safe Class A2S heat detector (45681-215 mounting base)

010p/23

Certified with Apollo Series 90 and XP95 digital communications protocolOrbis Class A1R Heat detectors with Apollo Approval Reference* 00001 (Approved for use with base

styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)

ORB-HT-11001-APO Orbis class A1R heat detector with SensAlert and FasTest

010r/01

Page 179: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 169

Certificated Products LPCB Ref. No.

ORB-HT-11013-APO Orbis class A1R heat detector with Flashing LED, SensAlert and FasTestOAX-HT-11019-APO Orbis class A1R heat detector with SensAlertOPX-HT-11025-APO Orbis class A1R heat detector with SensAlertOEX-HT-11037-APO Orbis class A1R heat detector with Flashing LED and SensAlertOIX-HT-11043-APO Orbis class A1R heat detector with Flashing LED and SensAlertOMX-HT-11049-APO Orbis class A1R heat detector with SensAlertOSX-HT-11061-APO Orbis class A1R heat detector with Flashing LED and SensAlertOMX-HT-11071-APO Orbis class A1R heat detector with Flashing LED and SensAlertOAX-HT-11077-APO Orbis class A1R heat detector with Flashing LED and SensAlertOEX-HT-11089-APO Orbis class A1R heat detector with SensAlertOSX-HT-11095-APO Orbis class A1R heat detector with SensAlertOPX-HT-11125-APO Orbis class A1R heat detector with Flashing LED and SensAlertOLX-HT-11137-APO Orbis class A1R heat detector with SensAlert and FasTest

Orbis Class A2S Heat detectors with Apollo Approval Reference* 00002 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)

ORB-HT-11002-APO Orbis class A2S heat detector with SensAlert and FasTestORB-HT-11014-APO Orbis class A2S heat detector with Flashing LED, SensAlert and FasTestOAX-HT-11020-APO Orbis class A2S heat detector with SensAlertOPX-HT-11026-APO Orbis class A2S heat detector with SensAlertOEX-HT-11038-APO Orbis class A2S heat detector with Flashing LED and SensAlertOIX-HT-11044-APO Orbis class A2S heat detector with Flashing LED and SensAlertOMX-HT-11050-APO Orbis class A2S heat detector with SensAlertOSX-HT-11062-APO Orbis class A2S heat detector with Flashing LED and SensAlertOMX-HT-11072-APO Orbis class A2S heat detector with Flashing LED and SensAlertOAX-HT-11078-APO Orbis class A2S heat detector with Flashing LED and SensAlertOEX-HT-11090-APO Orbis class A2S heat detector with SensAlertOSX-HT-11096-APO Orbis class A2S heat detector with SensAlertOPX-HT-11126-APO Orbis class A2S heat detector with Flashing LED and SensAlert OLX-HT-11138-APO Orbis class A2S heat detector with SensAlert and FasTest

010r/02

Orbis Class BR Heat detectors with Apollo Approval Reference* 00003 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)

ORB-HT-11003-APO Orbis class BR heat detector with SensAlert and FasTestORB-HT-11015-APO Orbis class BR heat detector with Flashing LED, SensAlert and FasTestOAX-HT-11021-APO Orbis class BR heat detector with SensAlertOPX-HT-11027-APO Orbis class BR heat detector with SensAlertOEX-HT-11039-APO Orbis class BR heat detector with Flashing LED and SensAlertOIX-HT-11045-APO Orbis class BR heat detector with Flashing LED and SensAlertOMX-HT-11051-APO Orbis class BR heat detector with SensAlertOSX-HT-11063-APO Orbis class BR heat detector with Flashing LED and SensAlertOMX-HT-11073-APO Orbis class BR heat detector with Flashing LED and SensAlertOAX-HT-11079-APO Orbis class BR heat detector with Flashing LED and SensAlertOEX-HT-11091-APO Orbis class BR heat detector with SensAlertOSX-HT-11097-APO Orbis class BR heat detector with SensAlertOPX-HT-11127-APO Orbis class BR heat detector with Flashing LED and SensAlertOLX-HT-11139-APO Orbis class BR heat detector with SensAlert and FasTest

010r/03

Orbis Class BS Heat detectors with Apollo Approval Reference* 00004 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base

ORB-HT-11004-APO Orbis class BS heat detector with SensAlert and FasTestORB-HT-11016-APO Orbis class BS heat detector with Flashing LED, SensAlert and FasTestOAX-HT-11022-APO Orbis class BS heat detector with SensAlertOPX-HT-11028-APO Orbis class BS heat detector with SensAlertOEX-HT-11040-APO Orbis class BS heat detector with Flashing LED and SensAlertOIX-HT-11046-APO Orbis class BS heat detector with Flashing LED and SensAlertOMX-HT-11052-APO Orbis class BS heat detector with SensAlertOSX-HT-11064-APO Orbis class BS heat detector with Flashing LED and SensAlertOMX-HT-11074-APO Orbis class BS heat detector with Flashing LED and SensAlertOAX-HT-11080-APO Orbis class BS heat detector with Flashing LED and SensAlertOEX-HT-11092-APO Orbis class BS heat detector with SensAlertOSX-HT-11098-APO Orbis class BS heat detector with SensAlertOPX-HT-11128-APO Orbis class BS heat detector with Flashing LED and SensAlertOLX-HT-11140-APO Orbis class BS heat detector with SensAlert and FasTest

010r/04

Orbis Class CR Heat detectors with Apollo Approval Reference* 00005 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base

ORB-HT-11005-APO Orbis class CR heat detector with SensAlert and FasTest

010r/05

Page 180: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

170 31 Dec 2012

Certificated Products LPCB Ref. No.

ORB-HT-11017-APO Orbis class CR heat detector with Flashing LED, SensAlert and FasTestOAX-HT-11023-APO Orbis class CR heat detector with SensAlertOPX-HT-11029-APO Orbis class CR heat detector with SensAlertOEX-HT-11041-APO Orbis class CR heat detector with Flashing LED and SensAlertOIX-HT-11047-APO Orbis class CR heat detector with Flashing LED and SensAlertOMX-HT-11053-APO Orbis class CR heat detector with SensAlertOSX-HT-11065-APO Orbis class CR heat detector with Flashing LED and SensAlertOMX-HT-11075-APO Orbis class CR heat detector with Flashing LED and SensAlertOAX-HT-11081-APO Orbis class CR heat detector with Flashing LED and SensAlertOEX-HT-11093-APO Orbis class CR heat detector with SensAlertOSX-HT-11099-APO Orbis class CR heat detector with SensAlertOPX-HT-11129-APO Orbis class CR heat detector with Flashing LED and SensAlertOLX-HT-11141-APO Orbis class CR heat detector with SensAlert and FasTest

Orbis Class CS Heat detectors with Apollo Approval Reference* 00006 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base

ORB-HT-11006-APO Orbis class CS heat detector with SensAlert and FasTestORB-HT-11018-APO Orbis class CS heat detector with Flashing LED, SensAlert and FasTestOAX-HT-11024-APO Orbis class CS heat detector with SensAlertOPX-HT-11030-APO Orbis class CS heat detector with SensAlertOEX-HT-11042-APO Orbis class CS heat detector with Flashing LED and SensAlertOIX-HT-11048-APO Orbis class CS heat detector with Flashing LED and SensAlertOMX-HT-11054-APO Orbis class CS heat detector with SensAlertOSX-HT-11066-APO Orbis class CS heat detector with Flashing LED and SensAlertOMX-HT-11076-APO Orbis class CS heat detector with Flashing LED and SensAlertOAX-HT-11082-APO Orbis class CS heat detector with Flashing LED and SensAlertOEX-HT-11094-APO Orbis class CS heat detector with SensAlertOSX-HT-11100-APO Orbis class CS heat detector with SensAlertOPX-HT-11130-APO Orbis class CS heat detector with Flashing LED and SensAlertOLX-HT-11142-APO Orbis class CS heat detector with SensAlert and FasTest

010r/06

Orbis Class A1S Heat detectors with Apollo Approval Reference* 00009 (Approved for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base

ORB-HT-11166-APO Orbis class A1S heat detector with SensAlert and FasTestORB-HT-11167-APO Orbis class A1S heat detector with Flashing LED, SensAlert and FasTest

010r/07

Orbis IS Class A1R Intrinsically safe heat detectors with Apollo Approval Reference* 50001 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base

ORB-HT-51145-APO Orbis intrinsically safe class A1R heat detector with SensAlert and FasTestORB-HT-51146-APO Orbis intrinsically safe class A1R heat detector with Flashing LED, SensAlert and FasTest

010r/08

Orbis IS Class A2S Intrinsically safe heat detectors with Apollo Approval Reference* 50002 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base

ORB-HT-51147-APO Orbis intrinsically safe class A2S heat detector with SensAlert and FasTestORB-HT-51148-APO Orbis intrinsically safe class A2S heat detector with Flashing LED, SensAlert and FasTest

010r/09

Orbis IS Class BR Intrinsically safe heat detectors with Apollo Approval Reference* 50003 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base

ORB-HT-51149-APO Orbis intrinsically safe class BR heat detector with SensAlert and FasTestORB-HT-51150-APO Orbis intrinsically safe class BR heat detector with Flashing LED, SensAlert and FasTest

010r/10

Orbis IS Class BS Intrinsically safe heat detectors with Apollo Approval Reference* 50004 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base

ORB-HT-51151-APO Orbis intrinsically safe class BS heat detector with SensAlert and FasTestORB-HT-51152-APO Orbis intrinsically safe class BS heat detector with Flashing LED, SensAlert and FasTest

010r/11

Orbis IS Class CR Intrinsically safe heat detectors with Apollo Approval Reference* 50005 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base

ORB-HT-51153-APO Orbis intrinsically safe class CR heat detector with SensAlert and FasTestORB-HT-51154-APO Orbis intrinsically safe class CR heat detector with Flashing LED,

010r/12

Page 181: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 171

Certificated Products LPCB Ref. No.

SensAlert and FasTestOrbis IS Class CS Intrinsically safe heat detectors with Apollo Approval Reference* 50006 (Approved for

use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base)

ORB-HT-51155-APO Orbis intrinsically safe class CS heat detector with SensAlert and FasTestORB-HT-51156-APO Orbis intrinsically safe class CS heat detector with Flashing LED, SensAlert and FasTest

010r/13

Orbis IS Class A1S Intrinsically safe heat detectors with Apollo Approval Reference* 50009 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008 adapter base

ORB-HT-51157-APO Orbis intrinsically safe class A1S heat detector with SensAlert and FasTestORB-HT-51158-APO Orbis intrinsically safe class A1S heat detector with Flashing LED, SensAlert and FasTest

010r/14

Bases:45681-200 Series 60 mounting base45681-200 Series 60/65 Mounting Base45681-201 Series 60 diode mounting base45681-201 Series 60/65 Diode Mounting Base45681-207 Series 60 intrinsically safe mounting base45681-209 XP95/Discovery standard deep mounting base45681-210 XP95 mounting base45681-215 XP95 intrinsically safe mounting base45681-245 Series 65 Relay mounting base45681-246 Series 65 Auxiliary relay mounting base45681-247 Series 65 EOL 12 Volt mounting base45681-248 Series 65 EOL 24 Volt mounting base45681-500 XPlorer standard mounting base45681-501 XPlorer remote LED mounting baseTimeSaver bases with Apollo Approval Reference* OBTimeSaver LX bases with Apollo Approval Reference* OLTimeSaver diode bases with Apollo Approval Reference* ODTimeSaver relay bases with Apollo Approval Reference* ORTimeSaver LX diode bases with Apollo Approval Reference* DXTimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking)TimeSaver deep bases with Apollo Approval Reference*EB: ORB-MB-00019-APO TimeSaver deep baseORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207)ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201)XPA-WB-10022-APO Radio link mounting base**

* The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS

Certificate No: 010q to EN 54: Part 7: 2000Certificate No: 010s to EN 54: Part 7: 2000Certificate No: 010ac to EN 54-7: 2000 + A1: 2002

Smoke DetectorsCertificated Products LPCB Ref.

No.XPA-OP-12034-APO Xpander addressable radio linked photoelectric smoke detector (XPA-WB-10022-APO

mounting base)010ac/01

Notes: 1) The complete radio base/detector combination is available as Apollo Part No.: XPA-

CB-12034-APO.2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells.

3) The radio link functionality is not included within the scope of approval.59000-600 Xplorer Analogue addressable optical smoke detector (45681-500 and 45681-501 mounting

bases)010q/01

Certificated with Apollo Series 90 and XP95 digital communication protocols58000-500 Discovery Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting

base)2010q/02

Note: Meets the requirements of EN 54:Part 7 in modes 1, 2, 3, 4, 5 and in conventional mode. Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols

Page 182: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

172 31 Dec 2012

Certificated Products LPCB Ref. No.

that have been configured for the Discovery ionisation smoke detectors has been configured in accordance with manufacturer's instructions.

58000-600 Discovery Analogue addressable photoelectric smoke detector (45681-209 and 45681-210 mounting base)2

010q/03

Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions.

55000-215 Series 65 Conventional ionisation smoke detector - Flashing LED/Reed switch (45681-200 mounting base)

010q/04

Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-216 Series 65 Conventional ionisation smoke detector - Flashing LED (45681-200 mounting base) 010q/05Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-217 Series 65 Conventional ionisation smoke detector - Standard (45681-200 mounting base) 010q/06Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-218 Series 65 Conventional integrating ionisation smoke detector - Flashing LED/Reed switch (45681-200 mounting base)

010q/07

Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-219 Series 65 Conventional integrating ionisation smoke detector - Flashing LED (45681-200 mounting base)

010q/08

Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-220 Series 65 Conventional integrating ionisation smoke detector - Standard (45681-200 mounting base)

010q/09

Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-315 Series 65 Conventional optical smoke detector - Flashing LED/Reed switch (45681-200 mounting base)

010q/10

Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-316 Series 65 Conventional optical detector - Flashing LED (45681-200 mounting base) 010q/11Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-317 Series 65 Conventional optical smoke detector - Standard (45681-200 mounting base) 010q/12Also Certificated for use with 45681-245, 45681-246, 45681-247, 45681-248 and 45681-201 mounting bases

55000-500 XP95 Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2

010q/16

Certificated with Apollo Discovery, XP95, and S90 digital communication protocolsthat have been configured for the Discovery ionisation smoke detectors in accordancewith manufacturers instructions .

55000-520 XP95 Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2

010q/17

Certificated with Apollo Discovery, XP95, and S90 digital communication protocolsthat have been configured for the Discovery ionisation smoke detectors in accordancewith manufacturers instructions .

55000-600 XP95 Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base) 2

010q/18

Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions.

55000-620 XP95 Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base) 2

010q/19

Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions.

55000-560 XP95 Analogue addressable ionisation smoke detector (45681-209 and 45681-210 mounting base) 2

010q/20

Certificated with Apollo Discovery, XP95, and S90 digital communication protocolsthat have been configured for the Discovery ionisation smoke detectors in accordancewith manufacturers instructions .

55000-660 XP95 Analogue addressable optical smoke detector (45681-209 and 45681-210 mounting base)2

010q/21

Certificated with Apollo Discovery, XP95, and S90 digital communication protocols that have been configured for the Discovery optical smoke detectors in accordance with manufacturers instructions.

55000-640 XP95 IS Analogue addressable intrinsically safe optical smoke detector (45681-215 mounting base)

010q/22

Certified with Apollo Series 90 and XP95 digital communications protocol

Page 183: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 173

Certificated Products LPCB Ref. No.

55000-540 XP95 IS Analogue addressable intrinsically safe ionisation smoke detector (45681-215 mounting base)

010q/23

Certified with Apollo Series 90 and XP95 digital communications protocolOrbis Optical smoke detectors with Apollo Approval Reference* 00007 (Approved for use with

base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)

ORB-OP-12001-APO Orbis optical smoke detector with SensAlert, FasTest and DirtAlertORB-OP-12003-APO Orbis optical smoke detector with Flashing LED, SensAlert, FasTest and DirtAlertOAX-OP-12004-APO Orbis optical smoke detector with SensAlertOPX-OP-12005-APO Orbis optical smoke detector with SensAlert and DirtAlertOEX-OP-12007-APO Orbis optical smoke detector with Flashing LED and SensAlertOIX-OP-12008-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlertOMX-OP-12009-APO Orbis optical smoke detector with SensAlert and DirtAlertOSX-OP-12011-APO Orbis optical smoke detector with Flashing LED and SensAlertOMX-OP-12013-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlertOAX-OP-12014-APO Orbis optical smoke detector with Flashing LED and SensAlertOEX-OP-12016-APO Orbis optical smoke detector with SensAlertOSX-OP-12017-APO Orbis optical smoke detector with SensAlertOPX-OP-12023-APO Orbis optical smoke detector with Flashing LED, SensAlert and DirtAlertOLX-OP-12025-APO Orbis optical smoke detector with SensAlert and FasTest

010s/01

Orbis IS Intrinsically safe optical smoke detectors with Apollo Approval Reference* 50007 (Approved for use with base styles OB (+ATEX marking) and ORB-BA-50008-APO adapter base

ORB-OP-52027-APO Orbis intrinsically safe optical smoke detector with SensAlert, FasTest and DirtAlertORB-OP-52028-APO Orbis intrinsically safe optical smoke detector with Flashing LED, SensAlert, FasTest and DirtAlert

010s/02

Bases:45681-200 Series 60 mounting base45681-200 Series 60/65 Mounting Base45681-201 Series 60 diode mounting base45681-201 Series 60/65 Diode Mounting Base45681-207 Series 60 intrinsically safe mounting base45681-209 XP95/Discovery standard deep mounting base45681-210 XP95 mounting base45681-215 XP95 intrinsically safe mounting base45681-245 Series 65 Relay mounting base45681-246 Series 65 Auxiliary mounting base45681-247 Series 65 EOL 12 Volt mounting base45681-248 Series 65 EOL 24 Volt mounting base45681-500 XPlorer standard mounting base45681-501 XPlorer remote LED mounting baseTimeSaver bases with Apollo Approval Reference* OBTimeSaver LX bases with Apollo Approval Reference* OLTimeSaver diode bases with Apollo Approval Reference* ODTimeSaver relay bases with Apollo Approval Reference* ORTimeSaver LX diode bases with Apollo Approval Reference* DXTimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking)ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207)ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201)XPA-WB-10022-APO Radio link mounting base**

* The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations. **Base manufactured by EMS

Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002 & CEA 4021:2003Certificate No: 010m to CEA 4021: 1999-06(en)Certificate No: 010t to EN 54-7: 2000 & CEA 4021: 1999-06Certificate No: 010ad to EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003

Page 184: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

174 31 Dec 2012

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.XPA-OH-13032-APO Xpander addressable radio linked photoelectric multisensor smoke detector (XPA-WB-

10022-APO mounting base)010ad/01

Notes:1) The complete radio base/detector combination is available as Apollo Part No.: XPA-

CB-13032-APO.2) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells.3) The radio link functionality is not included within the scope of approval.

58000-700 Discovery Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base) 010h/01Note: Certificated at the following settings.Mode 1 - High sensitivity smoke detector with standard heat enhancement.Mode 2 - Smoke detection only.Mode 3 - Medium sensitivity smoke detector with standard heat enhancement.Mode 4 - Low sensitivity smoke detector with high heat enhancement.Mode 5 - Class A1 heat detector.Also Certificated in conventional alarm modes 1, 2, 3, 4 and 5.Certificated with Discovery XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detector in accordance with manufacturer's instructions.

55000-885 XP95 Analogue addressable multisensor detector (45681-209 and 45681-210 mounting base)1 010m/01Certificated with Apollo, Discovery, XP95 and S90 digital communication protocols that have been configured for the Discovery multisensor detectorin accordance with manufacturer's instructions.

Orbis Multisensor smoke detectors with Apollo Approval Reference* 00008 for use with base styles OB, OL, OD, DX, OR, EB and ORB-BA-10008-APO adaptor base)

ORB-OH-13001-APO Orbis multisensor smoke detector with SensAlert, FasTest and DirtAlertORB-OH-13003-APO Orbis multisensor smoke detector with Flashing LED, SensAlert, FasTest and DirtAlertOAX-OH-13004-APO Orbis multisensor smoke detector with SensAlertOPX-OH-13005-APO Orbis multisensor smoke detector with SensAlert and DirtAlertOEX-OH-13007-APO Orbis multisensor smoke detector with Flashing LED and SensAlertOIX - OH-13008-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlertOMX-OH-13009-APO Orbis multisensor smoke detector with SensAlert and DirtAlertOSX-OH-13011-APO Orbis multisensor smoke detector with Flashing LED and SensAlertOMX-OH-13013-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlertOAX-OH-13014-APO Orbis multisensor smoke detector with Flashing LED and SensAlertOEX-OH-13016-APO Orbis multisensor smoke detector with SensAlertOSX-OH-13017-APO Orbis multisensor smoke detector with SensAlertOPX-OH-13023-APO Orbis multisensor smoke detector with Flashing LED, SensAlert and DirtAlertOLX-OH-13025-APO Orbis multisensor smoke detector with SensAlert and FasTest

010t/01

Orbis IS Intrinsically safe multisensor detectors with Apollo Approval Reference* 50008(Approved for use with base styles OB (+ATEX marking) and ORB-MB-50008-APO adapter base)

ORB-OH-53027-APO Orbis intrinsically safe multisensor detector with SensAlert, FasTest and DirtAlertORB-OH-53028-APO Orbis intrinsically safe multisensor detector with Flashing LED, SensAlert, FasTest and DirtAlert

010t/02

Bases:45681-209 XP95/Discovery standard deep mounting base45681-210 XP95 mounting baseTimeSaver bases with Apollo Approval Reference* OBTimeSaver LX bases with Apollo Approval Reference* OLTimeSaver diode bases with Apollo Approval Reference* ODTimeSaver relay bases with Apollo Approval Reference* ORTimeSaver LX diode bases with Apollo Approval Reference* DXTimeSaver IS bases with Apollo Approval Reference* OB (+ATEX marking)ORB-BA-50008 Orbis intrinsically safe adapter base (to be used in conjunction with the following bases only: 45681-207)ORB-BA-10008-APO Orbis adaptor base (to be used in conjunction with the following bases only: 45681-200 & 45681-201)XPA-WB-10022-APO Radio link mounting base**

Page 185: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 175

* The Apollo ‘Approval Reference Number’ identifies a group of detectors that all have the same physical construction, but have features enabled or disabled via their software, and/or regional marking variations.

**Base manufactured by EMS

Certificate No: 010an to EN 54-10: 2002 + A1:2005

Flame DetectorsCertificated Products LPCB Ref.

No.55000-022 XP95 intelligentflame detector (45681-209 and 45681-210) 010an/01

Note: Meets EN 54-10: 2002 at Class 1 and Class 355000-023 XP95 intelligent 2 flame detectorand 45681-210) 010an/02

Note: Meets EN 54-10: 2002 at Class 1 and Class 355000-024 XP95 intelligent 3 flame detectorand 45681-210) 010an/03

Note: Meets EN 54-10: 2002 at Class 1 and Class 355000-025 S65 conventional UV flame detector (45681-200 and 45681-201) 010an/04

Note: Meets EN 54-10: 2002 at Class 1 and Class 355000-019 Conventional IR 3 Flame Detector (29600-203) 010an/05

Note: Meets EN 54-10: 2002 at Class 1 only

55000-060 Conventional IR² Flame Detector (29600-203) 010an/06Note: Meets EN 54-10: 2002 at Class 1 only

55000-061 Conventional IR² (Exd) Flameproof Flame Detector (29600-203) 010an/07

Note: Meets EN 54-10: 2002 at Class 1 only

55000-062 Conventional IR 3 (Exd) Flameproof Flame Detector (29600-203) 010an/08Note: Meets EN 54-10: 2002 at Class 1 only

55000-063 Conventional IR 3 Intrinsically Safe Flame Detector (29600-203) 010an/09Note: Meets EN 54-10: 2002 at Class 1 only

55000-064 Conventional UV/IR 2 Flame Detector (29600-203) 010an/10Note: Meets EN 54-10: 2002 at Class 1 only

55000-065 Conventional UV/IR 2 (Exd) Flameproof Flame Detector (29600-203) 010an/11Note: Meets EN 54-10: 2002 at Class 1 only

55000-282 Analogue Addressable IR 3 Intrinsically Safe Flame Detector (29600-203) 010an/12Note: Meets EN 54-10: 2002 at Class 1 only

Bases

45681-200 Mounting Base45681-201 Mounting Base with Diode45681-209 Deep Base45681-210 Mounting Base

Ancillaries

29600-203 Mounting Bracket

Certificate No: 010aq to LPS 1274: 2005, EN 54-5: 2000 + A1: 2002 and LPS 1265: 2004

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.58000-305 Analogue addressable CO/heat multisensor detector

(45681-210, standard intelligent mounting base)010aq/01

Notes:1. Approved with the following mode configurations:-

Mode 1 30 ppm with high thermal enhancement (most sensitive)Mode 2 33 ppm with CO onlyMode 3 40 ppm with low thermal enhancement (nominal sensitivity)

Page 186: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

176 31 Dec 2012

Certificated Products LPCB Ref. No.

Mode 4 45 ppm with high thermal enhancement (least sensitive) Mode 5 heat onlyA1R

2. Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 20023. Mode 2 is approved to LPS 1265:20044. Mode 5 is approved to EN 54-5:2000 + A1:2002

Conditions of approval include;

a) The 58000-305 should only be installed in accordance with the manufacturer’s recommendations.

b) The 58000-305 should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning/flaming fires.

c) Refer to technical publication PP2382 for limitations on the use of carbon monoxide fire detection.

Base:45681-210 Standard intelligent mounting base

Certificate No: 010at to EN 54-17: 2005

Isolating baseCertificated Products LPCB Ref.

No.45681-505 Negative switching isolating base 010at/01

Certificate No: 010ar to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.55000-465 Analogue addressable Classheat detector

(45681-200 , 45681-213 and 45681-505 mounting bases)010ar/01

55000-475 Analogue addressable Classheat detector (45681-200 , 45681-213 and 45681-505 mounting bases)

010ar/02

Bases:45681-200 Mounting base45681-213 Common mounting base45681-505 Negative switching isolating base

Certificate No: 010as to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.55000-665 Analogue addressable optical smoke

(45681-200 , 45681-213 and 45681-505 mounting bases)010as/01

Bases:45681-200 Mounting base45681-213 Common mounting base45681-505 Negative switching isolating base

Page 187: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 177

Argus Security S.r.l.Via del Canneto 14, Valle delle Noghere, 34015 Muggia, Trieste, ItalyTel: +39 (0) 402821110 • Fax: +39 (0) 402823483E-mail: [email protected] • Website: www.argussecurity.it

Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005Certificate No: 928d to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.V350 Analogue addressable Class P heat detector with short circuit isolator (VB100, UB100,

VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)928a/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

A3500 Addressable Class P heat detector with short-circuit isolator (LAB100 base) 928a/02Note:1. Meets the requirements of EN 54-5 for Class A1R, Class B and Class BS

LV350 Vega-Lite analogue addressable Class P, heat detector (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)

928d/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B.

S3500 Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100)

928d/02

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B

BasesVB100 Vega adaptor mounting base (with link resistor)UB100 Universal adaptor mounting baseVB100S Vega adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVDBS100 Vega deep adaptor baseDBS100 Deep adaptor baseVDBS100S Vega deep adaptor base with shorting clipDBS100S Deep adaptor base with shorting clipUBR100 Universal adaptor base with resistorDBSR100 Deep adaptor base with resistorUBDR100 Universal adaptor base with resistor and Schottky diodeDBSRD100 Deep adaptor base with resistor and Schottky diodeLAB100 Standard mounting base

Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.V100 Analogue addressable photoelectric smoke detector with short circuit

isolator (VB100, UB100, VB100S, UB100S, VDBS100, DBS100,VDBS100S and DBS100S bases)

928b/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - HighOptical only level 2Optical only level 3Optical only level 4 - Low

A1000 Addressable photoelectric smoke detector with short-circuit isolator (LAB100 base) 928b/02Notes:

1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - HighOptical only level 2 Optical only level 3 Optical only level 4 - Low

Page 188: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

178 31 Dec 2012

Certificated Products LPCB Ref. No.

LV100 Vega-Lite analogue addressable optical smoke detector (VB100,UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S andDBS100S bases)

928e/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - HighOptical only level 2 Optical only level 3 Optical only level 4 - Low

S1000 Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100and DBSRD100)

928e/02

BasesVB100 Vega adaptor mounting base (with link resistor)UB100 Universal adaptor mounting baseVB100S Vega adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVDBS100 Vega deep adaptor baseDBS100 Deep adaptor baseVDBS100S Vega deep adaptor base with shorting clipDBS100S Deep adaptor base with shorting clipUBR100 Universal adaptor base with resistorDBSR100 Deep adaptor base with resistorUBDR100 Universal adaptor base with resistor and Schottky diodeDBSRD100 Deep adaptor base with resistor and Schottky diodeLAB100 Standard mounting base

Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multisensor DetectorsCertificated Products LPCB Ref.

No.V200 Analogue addressable Class P heat and photoelectric smoke multi

sensor detector with short circuit isolator (VB100, UB100, VB100S,UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)

928c/01

Notes1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat responseMulti Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat responseMulti Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat responseMulti Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3 Optical only level 4 - Low

A2000 Addressable multi-criteria detector with short-circuit isolator (LAB100 base) 928c/02Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat responseMulti Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat responseMulti Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat responseMulti Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

Page 189: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 179

Certificated Products LPCB Ref. No.

3. Meets the requirements of EN 54-7 at the following sensitivity settings:Optical only level 1 - HighOptical only level 2 Optical only level 3 Optical only level 4 - Low

LV200 Vega-Lite analogue addressable photo thermal multisensor (VB100,UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S andDBS100S bases)

928f/01

Notes1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 2 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 3 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3 Optical only level 4 - Low

BasesVB100 Vega adaptor mounting base (with link resistor)UB100 Vega universal mounting baseVB100S Vega adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVDBS100 Vega deep adaptor baseDBS100 Deep adaptor baseVDBS100S Vega deep adaptor base with shorting clipDBS100S Deep adaptor base with shorting clipLAB100 Standard mounting base

Certificate No: 928j to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Heat DetectorsCertificated Products LPCB Ref.

No.SG350 Wireless heat detector (WAB100 base) 928j/01

Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR2032A (3 Vdc) - secondary battery

BasesWAB100 Wireless Adaptor Base

Certificate No: 928k to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.SG100 Wireless optical smoke detector (WAB100 base) 928k/01

Notes:1. Meets the requirements of EN 54-7 in the normal sensitivity setting2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR2032A (3 Vdc) - secondary battery

Page 190: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

180 31 Dec 2012

Certificated Products LPCB Ref. No.

BasesWAB100 Wireless Adaptor Base

Certificate No: 928m to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.SG200 Wireless multi-criteria detector (WAB100 base) 928m/01

Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity settings3. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR2032A (3 Vdc) - secondary battery

BasesWAB100 Wireless Adaptor Base

Argus-Spectrum65 Serdobolskaya St, St. Petersburg 197342, Russian FederationTel: +7 812 7037500 • Fax: +7 812 7037501E-mail: [email protected] • Website: www.argus-spectr.ru

Certificate No: 928k-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.SG100 Wireless optical smoke detector (WAB100 base) 928k/01

Notes:1. Meets the requirements of EN 54-7 in the normal sensitivity setting2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 - Wireless Adaptor Base

Certificate No: 928a-(cl-2) to 54-5: 2000 + A1: 2002 and EN 54 -17: 2005Certificate No: 928d-(cl-2) to EN 54-5: 2000 + A1: 2002Certificate No: 603d to EN 54-5: 2000 + A1: 2002Certificate No: 928j-(cl-3) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Point Heat DetectorsCertificated Products LPCB Ref.

No.S3500 Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100

and DBSRD100)603d/01

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B

V350 Analogue addressable Class P heat detector with short circuit isolator (VB100 and UB100 bases)

928a/01

Notes1. Meets the requirements of EN 54-5 for Class A1R and Class B.

LV350 Vega-Lite analogue addressable Class P, temperature detector (VB100 and UB100 928d/01

Page 191: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 181

Certificated Products LPCB Ref. No.

bases) Notes1. Meets the requirements of EN 54-5 for Class A1R and Class B.

SG350 Wireless heat detector (WAB100 base) 928j/01Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:BS100 Standard baseBSD100 Schottky Diode baseVB100 Vega adaptor mounting base (with link resistor)UB100 Universal adaptor baseDBS100 Deep adaptor baseUBR100 Universal adaptor base with resistorDBSR100 Deep adaptor base with resistorUBDR100 Universal adaptor base with resistor and Schottky diodeDBSRD100 Deep adaptor base with resistor and Schottky diodeWAB100 Wireless Adaptor Base

Certificate No: 928b-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005Certificate No: 928e-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 603c to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorCertificated Products LPCB Ref.

No.S1000 Conventional photo smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100

and DBSRD100)603c/01

V100 Analogue addressable photoelectric smoke detector with short circuit isolator (VB100 andUB100 bases)

928b/01

Notes1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low

LV100 Vega-Lite analogue addressable optical smoke detector (VB100 and UB100 bases) 928e/01

Notes1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 Low

BasesVB100 Vega adaptor mounting base (with link resistor)UB100 Vega universal mounting baseUB100 Universal adaptor baseDBS100 Deep adaptor baseUBR100 Universal adaptor base with resistorDBSR100 Deep adaptor base with resistorUBDR100 Universal adaptor base with resistor and Schottky diodeDBSRD100 Deep adaptor base with resistor and Schottky diode

Certificate No: 928c-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA4021: 2003Certificate No: 928f-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Page 192: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

182 31 Dec 2012

Multi-sensor DetectorsCertificated Products LPCB Ref.

No.V200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with

short circuit isolator (VB100 and UB100 bases)928c/01

Notes1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 2 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 3 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3

Optical only level 4 - Low

LV200 Vega-Lite analogue addressable photo thermal multisensor (VB100 and UB100 bases) 928f/01

Notes1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following

settings:Multi criteria level 1 (most sensitive) - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 2 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 3 - thermally enhanced smoke detection with Class A1 heat responseMulti criteria level 4 (least sensitive) - thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings:Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings:Optical only level 1 - HighOptical only level 2 Optical only level 3

Optical only level 4 - Low

BasesVB100 Vega adaptor mounting base (with link resistor)UB100 Vega universal mounting base

Certificate No: 928m-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.SG200 Wireless multi-criteria detector (WAB100 base) 928m/01

Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity setting3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Page 193: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 183

ATEIS Middle East FZCOLIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab EmiratesTel: +971 4 3262730 • Fax: +971 4 3262731E-mail: [email protected] • Website: www.ateis.ae

Certificate No: 928a-(cl-7) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005Certificate No: 928d-(cl-9) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.VELOX V350 Analogue addressable Class P heat detector with short circuit isolator (VELOX VB100,

UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases)

928a/01

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B

VELOX LV350 Analogue addressable Class P heat detector (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases)

928d/01

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B

X350 Conventional Class P heat detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100 bases)

928d/02

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B

BasesVELOX VB100 Velox adaptor baseUB100 Universal adaptor baseVELOX VB100S Velox adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVELOX VDBS100 Velox deep adaptor baseDBS100 Deep adaptor baseVELOX VDBS100S Velox deep adaptor base with shorting clipDBS100S Deep adaptor base with shorting clipUBR100 Universal adaptor base with resistorDBSR100 Deep adaptor base with resistorUBDR100 Universal adaptor base with resistor and Schottky diodeDBSRD100 Deep adaptor base with resistor and Schottky diode

Certificate No: 928b-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928e-(cl-9) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 928k-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.VELOX V100 Analogue addressable photoelectric smoke detector with short circuit isolator (VELOX

VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases)

928b/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

VELOX LV100 Analogue addressable photoelectric smoke detector (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases)

928e/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

X100 Conventional photoelectric smoke detector (UB100, DBS100, UBR100, DBSR100, UBDR100 and DBSRD100 bases)

928e/02

Page 194: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

184 31 Dec 2012

Certificated Products LPCB Ref. No.

VELOX WL100 Wireless optical smoke detector (WAB100 base) 928k/01Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

BasesVELOX VB100 Velox adaptor baseUB100 Universal adaptor baseVELOX VB100S Velox adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVELOX VDBS100 Velox deep adaptor baseDBS100 Deep adaptor baseVELOX VDBS100S Velox deep adaptor base with shorting clipDBS100S Deep adaptor base with shorting clipWAB100 Wireless Adaptor Base

Certificate No: 928c-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003Certificate No: 928f-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003Certificate No: 928m-(cl-4) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.VELOX V200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with

short circuit isolator (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases)

928c/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response 2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response 3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

VELOX LV200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector (VELOX VB100, UB100, VELOX VB100S, UB100S, VELOX VDBS100, DBS100, VELOX VDBS100S and DBS100S bases)

928f/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

VELOX WL200 Wireless multi-criteria detector (WAB100 base) 928m/01Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity setting

Page 195: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 185

Certificated Products LPCB Ref. No.

3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

BasesVELOX VB100 Velox adaptor baseUB100 Universal adaptor baseVELOX VB100S Velox adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVELOX VDBS100 Velox deep adaptor baseDBS100 Deep adaptor baseVELOX VDBS100S Velox deep adaptor base with shorting clipDBS100S Deep adaptor base with shorting clipWAB100 Wireless Adaptor Base

Certificate No: 928j-(cl-4) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Point Heat DetectorsCertificated Products LPCB Ref.

No.VELOX WL350 Wireless heat detector (WAB100 base) 928j/01

Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Bardic by Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United KingdomTel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210Website: www.bardic.co.uk

Certificate No: 199n to EN 54-5: 2000

Heat DetectorsCertificated Products LPCB Ref.

No.ZF03 class A2S Conventional fixed temperature heat detector

(2020B, 2020DB, 2020BSD, 2020DBSD bases)199n/10

ZF04 class BS Conventional fixed temperature heat detector(2020B, 2020DB, 2020BSD, 2020DBSD bases)

199n/11

ZF05 class A1R Conventional rate of rise heat detector(2020B, 2020DB, 2020BSD, 2020DBSD bases)

199n/12

Bases:2020B Standard base2020DB Deep base2020BSD Standard base with schottky diode2020DBSD Deep base with schottky diode

Certificate No: 199m to EN 54-7: 2000

Photoelectric DetectorsCertificated Products LPCB Ref.

No.ZF01 Conventional photoelectric detector

(2020B, 2020DB, 2020BSD, 2020DBSD bases)199m/05

Bases:

Page 196: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

186 31 Dec 2012

2020B Standard base2020DB Deep base2020BSD Standard base with schottky diode2020DBSD Deep base with schottky diode

Certificate No: 199p to EN 54-5: 2000, EN 54-7: 2000 & CEA 4021 1999

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.ZF02 Conventional photo thermal detector

(2020B, 2020DB, 2020BSD, 2020DBSD bases)199p/04

Bases:2020B Standard base2020DB Deep base2020BSD Standard base with schottky diode2020DBSD Deep base with schottky diode

Beijing Leader Huaxin Electronics Co. LtdNo. 17 Rongjing Eastern Road, Economy & Technology Developed Area, Beijing 100176, ChinaTel: +86 10 67876681 • Fax: +86 10 67863972E-mail: [email protected] • Website: www.beijingleader.com.cn

Certificate No: 987a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

JTY-GM-LD3000EN/A Analogue addressable photoelectric smoke detector(LD10EN base)

987a/01

Bases:LD10EN mounting base

Bristol Fire LtdThe Colin Saunders Innovation Centre, Mewburn Road, Banbury, Oxfordshire OX16 9PA, United KingdomTel: +44 1295 817623E-mail: [email protected] • Website: www.bristol-fire.com

Certificate No: 506b-(cl-2) to EN 54-7 : 2000 + A1: 2002 + A2: 2006, EN 54-5 : 2000 + A1 : 2002 and CEA 4021: 2003

Point Smoke DetectorsCertificated Products LPCB Ref.

No.BF-SH-0115-2 (2 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/01BF-SH-0115-3 (3 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/02BF-SH-0115-4 (4 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/03

BasesAHMB-031 mounting base

Certificate No: 506c-(cl-2) to EN 54-5: 2000 + A1 : 2002

Heat DetectorsCertificated Products LPCB Ref.

No.BF-H-0116-2 (2 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector

(AHMB-031 Base)506c/01

BF-H-0116-3 (3 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector 506c/02

Page 197: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 187

Certificated Products LPCB Ref. No.

(AHMB-031 Base)BF-H-0116-4 (4 Wire) Conventional Class A2 rate of rise and fixed temperature Heat detector

(AHMB-031 Base)506c/03

BasesAHMB-031 mounting base

Certificate No: 506a-(cl-3) to EN 54-7 : 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.BF-S-0111-2 (2 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base) 506a/02BF-S-0111-3 (3 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base) 506a/03BF-S-0111-4 (4 wire) Conventional Photoelectric smoke detector (AHMB-031-L Base) 506a/04

BasesAHMB-L Mounting baseAHMB-031 Mounting base

Ceasefire Industries Ltd"Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, IndiaTel: +91 -22-22854677, 22854678 • Fax: +91-22-66349069E-mail: [email protected] • Website: www.ceasefire.in

Certificate No: 117g-(cl-1) to EN54-5:2000

Point Heat DetectorsCertificated Products LPCB Ref.

No.DFJ-AE3 Class A1S conventional fixed temperature heat detector

(YBN-R/6 base)117g/02

DCD-CE3 Class CR conventional rate of rise high temperature heat detector(YBN-R/6 base)

117g/06

ACB-E Analogue addressable Class P heat detector(YBN-R/3 and YBO-R/SCI bases)

117g/09

Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.

BasesYBN-R/3 baseYBN-R/6 standard baseYBO-R/SCI isolator base

Certificate No: 358c-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.ALK-E (WHT) Analogue addressable optical smoke detector (White)

(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases) Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

358c/03

SLV-E3 (WHT) Conventional optical smoke detector (White)(YBN-R/6)

358c/05

BasesYBN-R/3 base YBN-R/6 standard baseYBO-R/SCI isolator baseYBO-BS base sounder

Page 198: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

188 31 Dec 2012

YBO-BSB base sounder and beacon

Chubb Fire LtdChubb House, Staines Road West, Sunbury on Thames TW16 7AR, United KingdomTel: +44 (0)1932 785588 • Fax: +44 (0)1932 777222E-mail: [email protected] • Website: www.chubb.co.uk

Certificate No: 118h to EN 54-7: 2000

Point Smoke DetectorsCertificated Products LPCB Ref.

No.Resonance High Sensitivity Laser

Analogue addressable photoelectric laser smoke detector (B501, B501DG and B5241EFT & B524IEFT-1 bases)

118h/01

Note: meets the requirements of EN 54-7: 2000 at sensitivities 7 to 9 inclusive

Bases:B501 Analogue sensor baseB501DG Analogue sensor deep baseB524IEFT Analogue sensor isolator base

Consilium Marine and Safety ABSalsmästaregatan 21 Box 8763, Gothenburg SE402 76, SwedenTel: +46 31 710 77 64 • Fax: +46 31 710 78 00E-mail: [email protected] • Website: www.consilium.se

Certificate No: 041k-(cl-1) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Photoelectric smoke and heat detectorsCertificated Products LPCB Ref.

No.EV-PP Analogue addressable combined photoelectric smoke and class A1 heat sensor 041k/01

Bases

UB-2 Universal baseUB-6 Universal base

Context Plus LtdExport House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United KingdomTel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817E-mail: [email protected] • Website: www.xportsales.com

Certificate No: 010u-(cl-2) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.55000-465IMC Analogue addressable Class A2S heat detector

45681-213IMC and 45681-505IMC bases)010u/04

55000-475IMC Analogue addressable Class CS heat detector45681-213IMC and 45681-505IMC bases)

010u/05

Bases45681-200IMC Mounting base45681-213IMC Common mounting base

Page 199: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 189

45681-505IMC Negative switching isolating base

Certificate No: 010v-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.55000-665IMC Analogue addressable optical smoke

45681-213IMC and 45681-505IMC bases)010v/02

Bases45681-200IMC Mounting base45681-213IMC Common mounting base45681-505IMC Negative switching isolating base

Control Equipment LimitedHillcrest Business Park, Dudley, West Midlands DY2 9AP, United KingdomTel: +44 (0)1384 458651 • Fax: +44 (0)1384 458972E-mail: [email protected] • Website: www.controlequipment.com

Certificate No: 681b-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA4021: 2003

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.FC460PC FIRE CLASS digital addressable photoelectric smoke, Class P heat and Carbon

Monoxide detector (4B, 4B-I, and 5B bases)681b/03

Notes:1. Approved with the following mode configurations:-- UNIV Universal optical smoke and A2S heat multi-criteria detector-RESIL Resilient optical smoke and A2S heat multi-criteria detector- Heat detector at Class A1R- HPO Heat enhanced optical smoke detector at Normal sensitivity

2. The Carbon Monoxide toxic gas/CCO modes are not approvedFC460PH FIRE CLASS digital addressable photoelectric smoke and Class P heat detector (4B, 4B-

I, and 5B bases)681b/05

Note:Approved with the following mode configurations:-- Heat detector at Class A1R

- Heat detector at Class A2S- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic.

Bases

4B, 4” universal mounting base4B-I, 4” isolator base5B, 5” universal mounting base

Certificate No: 681c-(cl-2) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.FC460H FIRE CLASS digital addressable Class P heat detector (4B, 4B-I and 5B bases) 681c/10

Note:Approved with the following mode configurations:-- Heat detector at Class A1R- Heat detector at Class A2S- Heat detector at Class CR

Page 200: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

190 31 Dec 2012

Bases

4B, 4” universal mounting base4B-I, 4” isolator base5B, 5” universal mounting base

Cooper SafetyWheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United KingdomTel: 01302 321541 • Fax: 01302 303220

Certificate No: 685j-(cl-1) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005Certificate No: 685j-(cl-2) to EN 54-7:2000 + A1:2002 + A2:2006 & EN 54-17:2005Certificate No: 685h-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 685h-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.CPD321 Conventional photoelectric smoke detector (MDB800/CDB300 base) 685h/01CPDB321 Conventional photoelectric smoke detector (FXN520/CDBB300 base) 685h/01FXN533 Conventional photoelectric smoke detector (FXN520/CDBB300 base) 685h/01MPD821 Conventional photoelectric smoke detector (MDB800/CDB300 base) 685h/01CAP320 Intelligent analogue addressable photoelectric smoke detector

(CAB300 base)685j/01

CAPB320 Intelligent analogue addressable photoelectric smoke detector(CABB300 base)

685j/01

COPP420 Intelligent analogue addressable photoelectric smoke detector(COPA800 base)

685j/01

FXN723 Intelligent analogue addressable photoelectric smoke detector(FXN720 base)

685j/01

MAP820 Intelligent analogue addressable photoelectric smoke detector (MAB800 base)

685j/01

Bases

MAB800 Standard analogue addressable mounting baseCABB300 Standard analogue addressable mounting baseFXN720 Standard analogue addressable mounting baseCAB300 Standard analogue addressable mounting baseCOPA800 Standard analogue addressable mounting baseMDB800/CDB300 Standard conventional mounting baseFXN520/CDBB300 Schottky conventional mounting base

Certificate No: 685k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July 2003(en)Certificate No: 685k-(cl-2) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: July 2003(en)Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003Certificate No: 685g-(cl-2) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.CPT341 Conventional photo/thermal multisensor and Class A2S heat detector (MDB800/CDB300

base)685g/01

CPTB341 Conventional photo/thermal multisensor and Class A2S heat detector (FXN520/CDBB300 base)

685g/01

FXN632 Conventional photo/thermal multisensor and Class A2S heat detector (FXN520/CDBB300 base)

685g/01

MPT951 Conventional photo/thermal multisensor and Class A2S heat detector (MDB800/CDB300 base)

685g/01

CXN633 Conventional photo/thermal multisensor and Class P heat detector (FXN520 Base) 685g/02Notes: 1. Meets the requirements of EN 54-7:2000

in the following modes:

Page 201: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 191

Certificated Products LPCB Ref. No.

Mode 1 - Thermally enhanced optical smoke detector Smoke sensitivity 0.15dB/m. Mode 2 - Optical smoke detector. Smoke sensitivity 0.1dB/m.

2. Meets the requirements of EN 54-5:2000 in the following modes: Mode 3 - Heat detector Class A1R Mode 4 - Heat detector Class BS Mode 5 - Heat detector Class CS

FXN922 Conventional photo/thermal multisensor and Class P heat detector (FXN520 Base) 685g/02Notes: 1. Meets the requirements of EN 54-7:2000

in the following modes: Mode 1 - Thermally enhanced optical smoke detector Smoke sensitivity 0.15dB/m. Mode 2 - Optical smoke detector. Smoke sensitivity 0.1dB/m.

2. Meets the requirements of EN 54-5:2000 in the following modes: Mode 3 - Heat detector Class A1R Mode 4 - Heat detector Class BS Mode 5 - Heat detector Class CS

MPT922 Conventional photo/thermal multisensor and Class P heat detector (FXN520 Base) 685g/02Notes: 1. Meets the requirements of EN 54-7:2000

in the following modes: Mode 1 - Thermally enhanced optical smoke detector Smoke sensitivity 0.15dB/m. Mode 2 - Optical smoke detector. Smoke sensitivity 0.1dB/m.

2. Meets the requirements of EN 54-5:2000 in the following modes: Mode 3 - Heat detector Class A1R Mode 4 - Heat detector Class BS Mode 5 - Heat detector Class CS

CAPT340 Intelligent analogue addressable Class A2S multisensor opto/heat detector (CAB300 base)

685k/01

Notes:1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S)

CAPTB340 Intelligent analogue addressable Class A2S multisensor opto/heat detector (CABB300 base)

685k/01

Notes:1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S)

COPOH450 Intelligent analogue addressable Class A2S multisensor opto/heat detector (COPA800 base)

685k/01

Notes:1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S)

FXN722 Intelligent analogue addressable Class A2S multisensor opto/heat detector (FXN720 base)

685k/01

Notes:1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only

Page 202: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

192 31 Dec 2012

Certificated Products LPCB Ref. No.

Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S)

MAOH850 Intelligent analogue addressable Class A2S multisensoropto/heat detector (MAB800 base)

685k/01

Notes:1) Meets the requirements of EN 54-5 and EN 54-7 in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S)

Bases

MAB800 Standard analogue addressable mounting baseCABB300 Standard analogue addressable mounting baseFXN720 Standard analogue addressable mounting baseCAB300 Standard analogue addressable mounting baseCOPA800 Standard analogue addressable mounting baseMDB800/CDB300 Standard conventional mounting baseFXN520/CDBB300 Schottky conventional mounting base

Certificate No: 685m-(cl-1) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005Certificate No: 685m-(cl-2) to EN 54-5: 2000+A1:2002 & EN 54-17: 2005

Heat DetectorsCertificated Products LPCB Ref.

No.CAH330 Intelligent analogue addressable Class P heat detector

(CAB300 base)685m/01

Notes:1) Meets the requirements of EN 54-5 at classes A1R, BS and CS

CAHB330 Intelligent analogue addressable Class P heat detector (CABB300 base)

685m/01

Notes:1) Meets the requirements of EN 54-5 at classes A1R, BS and CS

COPH430 Intelligent analogue addressable Class P heat detector (COPA800 base)

685m/01

Notes:1) Meets the requirements of EN 54-5 at classes A1R, BS and CS

FXN725 Intelligent analogue addressable Class P heat detector (FXN720 base)

685m/01

Notes:1) Meets the requirements of EN 54-5 at classes A1R, BS and CS

MAH830 Intelligent analogue addressable Class P heat detector (MAB800 base)

685m/01

Notes:1) Meets the requirements of EN 54-5 at classes A1R, BS and CS

Bases

MAB800 Standard analogue addressable mounting baseCABB300 Standard analogue addressable mounting baseFXN720 Standard analogue addressable mounting baseCAB300 Standard analogue addressable mounting baseCOPA800 Standard analogue addressable mounting base

Certificate No: 685a-(cl-1) to EN 54-5: 2000 + A1: 2002Certificate No: 685a-(cl-2) to EN 54-5: 2000 + A1: 2002

Page 203: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 193

Point Heat DetectorsCertificated Products LPCB Ref.

No.CFR330 Conventional Class A2R heat detector (MDB800/CDB300 base) 685a/01CFRB330 Conventional Class A2R heat detector (FXN520/CDBB300 base) 685a/01FXN525 Conventional Class A2R heat detector (FXN520/CDBB300 base) 685a/01MFR830 Conventional Class A2R heat detector (MDB800/CDB300 base) 685a/01CMT360 Conventional Class BS heat detector (MDB800/CDB300 base) 685a/02CMTB360 Conventional Class BS heat detector (FXN520/CDBB300 base) 685a/02FXN524 Conventional Class BS heat detector (FXN520/CDBB300 base) 685a/02MMT860 Conventional Class BS heat detector (MDB800/CDB300 base) 685a/02CHT390 Conventional Class CS heat detector (MDB800/CDB300 base) 685a/03CHTB390 Conventional Class CS heat detector (FXN520/CDBB300 base) 685a/03FXN526 Conventional Class CS heat detector (FXN520/CDBB300 base) 685a/03MHT890 Conventional Class CS heat detector (MDB800/CDB300 base) 685a/03

BasesMDB800/CDB300 Standard conventional mounting baseFXN520/CDBB300 Schottky conventional mounting base

Cooper Sécurité SASParc Européen d’Entreprises II, Rue Beethoven, BP 10184, 63204 Riom Cedex, FranceTel: +44 (0)1302 3397 • Fax: +44 (0)1302 303220E-mail: [email protected]

Certificate No: 685j-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 685h-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.DOFS3000 Conventional photoelectric smoke detector (NUG30255 base) 685h/01DOFA3000 Intelligent analogue addressable photoelectric smoke detector

(NUG30256 base)685j/01

Bases

NUG30256 Standard analogue addressable mounting baseNUG30255 Standard conventional mounting base

Certificate No: 685m-(cl-3) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005

Heat DetectorsCertificated Products LPCB Ref.

No.DTVA3000 Intelligent analogue addressable Class P heat detector (NUG30256 base) 685m/01

Notes: 1. Meets the requirements of EN 54-5 at classes A1R, BS and CS

Bases

NUG30256 Standard analogue addressable mounting base

Certificate No: 685k-(cl-3) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 , EN 54-17: 2005 and CEA4021: July 2003(en)Certificate No: 685g-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.DMCFS3000 Conventional photo/thermal multisensor and Class A2S heat detector (NUG30255 base) 685g/01DMCFA3000 Intelligent analogue addressable Class A2S multisensor opto/heat detector (NUG30256 685k/01

Page 204: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

194 31 Dec 2012

Certificated Products LPCB Ref. No.

base)Notes: 1. Meets the requirements of EN 54-5 and EN 54-7in the following modes: Mode 1 - Photoelectric/heat combined only Mode 2 - Photoelectric/heat combined together with an alarm output from temperature alone (Class A2S) Mode 3 - Heat detector alone (Class A2S)

Bases

NUG30255 Standard conventional mounting baseNUG30256 Standard analogue addressable mounting base

Certificate No: 685a-(cl-3) to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.DTVS3000 Conventional Class A2R heat detector (NUG30255 base) 685a/01DTS77°S3000 Conventional Class BS heat detector (NUG30255 base) 685a/02DTS90°S3000 Conventional Class CS heat detector (NUG30255 base) 685a/03

BasesNUG30255 Standard conventional mounting base

Daksh Electronics Private LimitedB-220, ESIP, Phase 1, Sitarganj, Udham Singh Nagar, Uttarakhand 262405, India

Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.SensoBIT-900-OSD Conventional photoelectric smoke detector (SensoBIT-900B base) 550a/05

Base:SensoBIT-900B standard base

Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.SensoBIT-900-OTD Conventional photo-thermal class A1R detector (SensoBIT-900B base) 550b/06

Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity

Base:SensoBIT-900B standard base

Certificate No: 550c to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.SensoBIT-900-HD Conventional A1R rate of rise heat detector (SensoBIT-900B base) 550c/08

Base:SensoBIT-900B standard base

Page 205: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 195

Detector Electronics Corporation6901 West 110th Street, Minneapolis, Minesota 55438, USATel: +001 952 946 6488E-mail: [email protected] • Website: www.det-tronics.com

Certificate No: 973a to EN 54-10: 2002 + A1: 2005 and EN 54-17: 2005Certificate No: 973e to EN 54-10: 2002 + A1: 2005

Certificated Products LPCB Ref. No.

X9800 Addressable Class 1 IR flame detector with short circuit isolator 973a/01Note : The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

X5200 Addressable Class 1 UV / IR flame detector with short circuit isolator 973a/02Note : The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

X3301 Addressable Class 1 multispectrum IR flame detector with short circuit isolator 973a/03Note: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

X2200 Addressable Class 1 UV flame detector with short circuit isolator 973a/04The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

X9800 Conventional Class 1 IR flame detector 973e/01X5200 Conventional Class 1 UV / IR flame detector 973e/02X3301 Conventional Class 1 multispectrum IR flame detector 973e/03X2200 Conventional Class 1 UV flame detector 973e/04

EMCO125 El Alamean Street, El Mohandessin, Cairo, EgyptTel: 00202 33 44 3 245 • Fax: 00202 330 36 86 0E-mail: [email protected] • Website: www.4emco.com

Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005Certificate No: 928d to EN 54-5: 2000 + A1: 2002

Certificated Products LPCB Ref. No.

AD203S Analogue addressable Class P heat detector with short circuit isolator (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases)

928a/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

AD203 Analogue addressable Class P heat detector lite (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases)

928d/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

BasesAB100 Universal adaptor baseAB100D Deep adaptor baseAB200 Vega adaptor baseAB200D Vega deep adaptor baseAB100-S Universal adaptor base with shorting clipAB100D-S Deep adaptor base with shorting clipAB200-S Vega adaptor base with shorting clipAB200D-S Vega deep adaptor base with shorting clip

Page 206: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

196 31 Dec 2012

Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

AD201S Analogue addressable photoelectric smoke detector with short circuit isolator (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases)

928b/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

AD201 Analogue addressable photoelectric smoke detector lite (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases)

928e/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

BasesAB100 Universal adaptor baseAB100D Deep adaptor baseAB200 Vega adaptor baseAB200D Vega deep adaptor baseAB100-S Universal adaptor base with shorting clipAB100D-S Deep adaptor base with shorting clipAB200-S Vega adaptor base with shorting clipAB200D-S Vega deep adaptor base with shorting clip

Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Certificated Products LPCB Ref. No.

AD202S Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with short circuit isolator (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases)

928c/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:

Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

AD202 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite (AB100, AB100D, AB200, AB200D, AB100-S, AB100D-S, AB200-S and AB200D-S bases)

928f/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:

Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response

Page 207: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 197

Certificated Products LPCB Ref. No.

Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

BasesAB100 Universal adaptor baseAB100D Deep adaptor baseAB200 Vega adaptor baseAB200D Vega deep adaptor baseAB100-S Universal adaptor base with shorting clipAB100D-S Deep adaptor base with shorting clipAB200-S Vega adaptor base with shorting clipAB200D-S Vega deep adaptor base with shorting clip

Emergi-Lite Safety Systems (Thomas & Betts Ltd)Bruntcliffe Lane, Morley, Leeds LS27 9LL, United KingdomTel: +44 (0)113 2810600 • Fax: +44 (0)113 2810601Website: www.emergi-lite.co.uk

Certificate No: 010p to EN 54-5:2000 + A1:2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.FADY-TEM Analogue addressable heat detector (FA95-ACB mounting base) 010p/03

Notes:1) Meets the requirements of EN54: Part 5 -

Class A1R in mode 1 and in conventional mode Class A2 in mode 2 and in conventional mode Class A2S in mode 3 and in conventional mode Class CR in mode 4 and in conventional mode Class CS in mode 5 and in conventional mode

2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions.

FAP6-RR6 Conventional Class A1R heat detector (FAP6-STB mounting base) 010p/06Notes:1) Meets the requirements of EN54: Part 5 - Class A1R

FAP6-RR75 Conventional Class BR heat detector (FAP6-STB mounting base) 010p/09Notes:1) Meets the requirements of EN54: Part 5 - Class BR

FAP6-RR90 Conventional Class CR heat detector (FAP6-STB mounting base) 010p/12Notes:1) Meets the requirements of EN54: Part 5 - Class CR

FAP6-FT8 Conventional Class CS heat detector (FAP6-STB mounting base) 010p/15Notes:1) Meets the requirements of EN54: Part 5 - Class CS

Bases:FAP6-STB Mounting base

Certificate No: 010h to EN 54-5:2000 + A1:2002, EN 54-7:2000 + A1:2002, CEA 4021:2003

Page 208: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

198 31 Dec 2012

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.FADY-MUS Analogue addressable multisensor detector (FA95-ACB mounting base) 010h/01

Notes:1) Certificated at the following settings:

Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector Also approved in conventional alarm modes 1, 2, 3, 4 and 5

2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions.

Bases:FA95-ACB Mounting baseFAP6-STB Diode mounting base

Certificate No: 010q to EN 54 - 7:2000 + A1:2002

Point Smoke DetectorsCertificated Products LPCB Ref.

No.FADY-OPT Analogue addressable optical smoke detector (FA95-ACB mounting base) 010q/03

Notes:1) Meets the requirements of EN54: Part 7 in modes 1, 2, 3, 4 and 5 and in conventional mode.2) Certificated with Apollo Discovery, XP95, and S90 digital communications protocols configured for the Discovery heat detector in accordance with manufacturers instructions.

FAP6-ION Conventional ionisation smoke detector (FAP6-STB mounting base) 010q/06FAP6-OPT Conventional optical smoke detector (FAP6-STB mounting base) 010q/12

Bases;FAP6-STB Mounting base

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)P.O.Box 22436, Industrial Area 13, Sharjah, United Arab EmiratesTel: +971 6 5340300 • Fax: +971 6 5340090E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 506a to EN 54-7: 2000

Point Smoke DetectorsCertificated Products LPCB Ref.

No.FX-0311-2 (2 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) 506a/02FX-0311-3 (3 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) 506a/03FX-0311-4 (4 - wire) Conventional photoelectric smoke detector (AHMB-031 Base) 506a/04

Bases:AHMB-031 mounting base

Certificate No: 506b to EN 43-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.FX-0315-2 (2 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) 506b/01FX-0315-3 (3 - wire) Optical smoke and Class A2 detector (AHMB-31 Base) 506b/02FX-0315-4 (4 - wire) Optical smoke and Class A2 heat detector (AHMB-31 Base) 506b/03

Bases:AHMB-031 mounting base

Page 209: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 199

Certificate No: 506c to EN54-5: 2000

Point Heat DetectorCertificated Products LPCB Ref.

No.FX-0316-2 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-

31 Base)506c/01

FX-0316-3 (3 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031 Base)

506c/02

FX-0316-4 (4 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-31 Base)

506c/03

Bases:AHMB-031 mounting base

Eurotech Fire Systems Ltd19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United KingdomTel: (0)203 141 0999E-mail: [email protected] • Website: www.eurotechfire.com

Certificate No: 041f-(cl-1) to EN54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 842a-(cl-2) to EN54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.EURV-P Analogue addressable optical smoke detector (EURB-4, EURB-4-EV, EURB-4SD and

EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.

041f/01

EURVC-P Conventional optical smoke detector(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)

041f/03

EURVC-P Conventional optical smoke detector(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)

842a/01

EURV-P Analogue addressable optical smoke detector(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.

842a/04

Bases

EURB-4 universal mounting baseEURB-4-EV universal mounting baseEURB-4SD universal mounting base with schottky diodeEURB-4SE-EV Standard deep base

Certificate No: 041g-(cl-1) to EN 54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 1999Certificate No: 041h-(cl-1) to EN54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.EURV-PH Analogue addressable optical smoke / class A1R heat detector (EURB-4, EURB-4-EV,

EURB-4SD and EURB-4SE-EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings.

041g/01

EURV-H-A1R Analogue addressable Class A1R heat detector(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)

041h/01

EURV-H-CS Analogue addressable Class CS heat detector(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)

041h/02

EURVC-H-A2S Conventional Class A2S heat detector(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)

041h/03

EURVC-H-CS Conventional Class CS heat detector(EURB-4, EURB-4-EV, EURB-4SD and EURB-4SE-EV bases)

041h/04

Bases

Page 210: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

200 31 Dec 2012

EURB-4 universal mounting baseEURB-4-EV universal mounting baseEURB-4SD universal mounting base with schottky diodeEURB-4SE-EV Standard deep base

Everday Technology Co. LimitedNo,.95., Sec. 2., Ligong 1 St. Road., Letzer Industrial Park, Yilan County 26841, Taiwan ROCTel: +886 3 990 6099 • Fax: +862 3 990 6029E-mail: [email protected] • Website: www.everday.com

Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.EA318-2 Conventional 2 wire photoelectric smoke detector 512a/01

(P/N852001 base)EA318-2(LED) Conventional 2 wire photoelectric smoke detector with remote LED output 512a/02

(P/N854001 base)EA318-4-12 Conventional 4 wire photoelectric smoke detector 512a/03

(P/N854001 base)EA318-4-24 Conventional 4 wire photoelectric smoke detector 512a/04

(P/N854001 base)EA318-2V Conventional 2 wire photoelectric smoke detector

(P/N852001 base)512a/05

EA318-2-LED-V Conventional 2 wire photoelectric smoke detector with remote LED output (P/N852001 base)

512a/06

EA318-4V-12 Conventional 4 wire photoelectric smoke detector(P/N854001 base)

512a/07

EA318-4V-24 Conventional 4 wire photoelectric smoke detector 512a/08

Bases:P/N854001 4-wire detector baseP/N852001 2-wire detector base

Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.EA318-2H Conventional 2 wire photoelectric smoke and heat detector 512b/01

(P/N852001 base)EA318-2H-LED Conventional 2 wire photoelectric smoke and heat detector with remote LED output 512b/02

(P/N854001 base)EA318-4H-12 Conventional 4 wire photoelectric smoke and heat detector 512b/03

(P/N854001 base)EA318-4H-24 Conventional 4 wire photoelectric smoke and heat detector 512b/04

(P/N854001 base)EA318-2HV Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base) 512b/05EA318-2H-LED-V Conventional 2 wire photoelectric smoke and heat detector with remote LED output

(P/N8524001 base)512b/06

EA318-4HV-12 Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) 512b/07EA318-4HV-24 Conventional 4 wire photoelectric smoke and heat detector (P/N854001 base) 512b/08

Bases:P/N854001 4-wire detector baseP/N852001 2-wire detector base

Certificate No: 512d to EN 54-5: 2000 + A1: 2002

Page 211: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 201

Point Heat DetectorsCertificated Products LPCB Ref.

No.EA323-2 Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector

(P/N852001 base)512d/01

EA323-2 Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N852001 base)

512d/02

EA323-2L Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base)

512d/03

EA323-2L Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base)

512d/04

EA323-4 Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/05

EA323-4 Conventional 4 wire 12VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/06

EA323-4 Conventional 4 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/07

EA323-4 Conventional 4 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/08

EA323-2V(A2S) Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector (P/N852001 base)

512d/09

EA323-2V(A2R) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N852001 base)

512d/10

EA323-2LV(A2S) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/11

EA323-2LV(A2R) Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N852001 base)

512d/12

EA323-4V-12(A2S) Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/13

EA323-4V-12(A2R) Conventional 4 wire 12VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/14

EA323-4V-24(A2S) Conventional 4 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/15

EA323-4V-24(A2R) Conventional 4 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/16

Bases:P/N852001 2-Wire detector baseP/N854001 4-Wire detector base

Fike Safety Technology LtdUnit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United KingdomTel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk

Certificate No: 331f to EN 54-3: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, EN 54-18: 2005 and CEA 4021:July 2003 (en)Certificate No: 331n to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17:2005, EN 54-18: 2005 and CEA 4021:July 2003 (en)Certificate No: 331g to EN 54-3: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: July 2003 (en)Certificate No: 331p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: July 2003 (en)

Multi-Sensor DetectorsCertificated Products LPCB Ref.

No.205-0001 Sita analogue addressable optical smoke and heat multisensor detector with short circuit

isolator and sounder.331f/01

Notes:1. Meets the requirements of EN 54-5:2000 at the following settings:

HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature.

2. Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement.

3. Approved at the following tones - SP1 Continuous 970Hz

Page 212: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

202 31 Dec 2012

Certificated Products LPCB Ref. No.

SP2 Pulsed 970Hz 1s on 1s off SP3 Dual Tone 970Hz 0.25s , 800Hz 0.25s SP4* Sweep Up 800-970Hz over 1s SP5 Slow Whoop 500-1200Hz over 3s, 0.5s off SP6* Sweep Down 1200-500Hz over 1s SP7 Dual French 550Hz 0.1s, 440Hz 400ms* Not available if the I/O facility is used.

205-0012 Sita analogue addressable optical smoke and heat multisensor detector with short circuit isolator and sounder/strobe.

331f/02

Notes:1. Meets the requirements of EN 54-5:2000 at the following settings:

HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature.

2. Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement.

3. Approved at the following tones - SP1 Continuous 970Hz SP2 Pulsed 970Hz 1s on 1s off SP3 Dual Tone 970Hz 0.25s , 800Hz 0.25s SP4* Sweep Up 800-970Hz over 1s SP5 Slow Whoop 500-1200Hz over 3s, 0.5s off SP6* Sweep Down 1200-500Hz over 1s SP7 Dual French 550Hz 0.1s, 440Hz 400ms* Not available if the I/O facility is used.

4. The strobe function is not approved.202-0001 Twinflex conventional optical smoke and heat multisensor detector with sounder 331g/01

Notes:1. Meets the requirements of EN 54-5:2000 at the following settings:HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature.

2. Meets the requirements of EN 54-7:2000 at the following settings:SM1 Standard optical sensitivity with high thermal enhancementSM2 Standard optical sensitivity with normal thermal enhancement.

3. Approved at the following tones - SP1 Continuous 970Hz SP2 Alternating Tone 800 0.25s / 970Hz 0.25s SP3 Sweep Up 800-970Hz over 1s

205-0003 Sita analogue addressable optical smoke and heat multisensor detector with short circuit isolator.

331n/01

Notes:1. Meets the requirements of EN 54-5:2000 at the following settings:

HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature.

2. Meets the requirements of EN 54-7:2000 at the following settings: SM1 Standard optical sensitivity with high thermal enhancement SM2 Standard optical sensitivity with normal thermal enhancement.

202-0003 Twinflex conventional optical smoke and heat multisensor detector 331p/01Notes: 1. Meets the requirements of EN 54-5:2000 at the following settings:HM1 Class A1 standard temperature rate of rise enhanced HM2 Class A1 standard temperature, fixed temperature.

2. Meets the requirements of EN 54-7:2000 at the following settings:SM1 Standard optical sensitivity with high thermal enhancementSM2 Standard optical sensitivity with normal thermal enhancement.

Bases45-0048-202 ASD Base25-0065-202 Base extension45-0306-202 Twinflex Multipoint Base

Page 213: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 203

Finder Elektronik A.S.Liman Mah., 6. Sok., No: 10 07070, Konyaalti, Antalya, TurkeyTel: +9 0242 344 2500 • Fax: +9 0242 344 2120E-mail: [email protected] • Website: www.finder.com.tr

Certificate No: 928a-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54 -17: 2005Certificate No: 928d-(cl-1) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.FF T200 Analogue addressable Class P heat detector with short circuit isolator (FF BS200 base) 928a/01

Notes1. Meets the requirements of EN 54-5 for Class A1R and Class B

FF T200L Analogue addressable Class P, temperature detector (FF BS200 base) 928d/01Notes1. Meets the requirements of EN 54-5 for Class A1R and Class B

FF T1000 Conventional Class P, heat detector (FF UBR200 and FF BRD200 bases) 928d/02Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B.

BasesFF BS200 Mounting base (with link resistor)FF UBR200 Universal adaptor base with resistorFF BRD200 Universal adaptor base with resistor and Schottky diode

Certificate No: 928b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54 -17: 2005Certificate No: 928e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 928k-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.FF O200 Analogue addressable photoelectric smoke detector with short circuit isolator (FF BS200

base)928b/01

Notes1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

FF O200L Analogue addressable optical smoke detector (FF BS200 base) 928e/01Notes1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

FF O1000 Conventional photo smoke detector (FF UBR200 and FF BRD200 bases) 928e/02FF SG100 Wireless optical smoke detector (WAB100 base) 928k/01

Notes:1. Meets the requirements of EN 54-7 in the normal sensitivity setting2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

BasesFF BS200 Mounting base (with link resistor)FF UBR200 Universal adaptor base with resistorFF BRD200 Universal adaptor base with resistor and Schottky diodeWAB100 Wireless Adaptor Base

Page 214: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

204 31 Dec 2012

Certificate No: 928c-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54 -17: 2005 & CEA 4021: 2003Certificate No: 928f-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Multi-sensor DetectorsCertificated Products LPCB Ref.

No.FT OT200 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with

short circuit isolator (FF BS200 base)928c/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:

Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3

Optical only level 4 - LowFF OT200L Analogue addressable optical smoke detector (FF BS200 base) 928f/01

Notes1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

BasesFF BS200 Mounting base (with link resistor)

Certificate No: 928j-(cl-5) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Point Heat DetectorsCertificated Products LPCB Ref.

No.FF SG350 Wireless heat detector (WAB100 base) 928j/01

Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Certificate No: 928m-(cl-5) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.FF SG200 Wireless multi-criteria detector (WAB100 base) 928m/01

Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity setting3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Page 215: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 205

Fireguard Safety Equipment Co Ltd2nd Floor, 145-147 St John Street, London EC1V 4PY, United KingdomTel: +44 (0)8450 751042 • Fax: +44 (0)845 2991039E-mail: [email protected] • Website: www.fireguard-uk.com

Certificate No: 512a-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 928e-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

Fireguard FG318-2L Conventional 2 wire photoelectric smoke detector with remove LED output (Fireguard P/N FG854001 base)

512a/02

FGSD100 Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - HighOptical only level 2 Optical only level 3 Optical only level 4 - Low

928e/01

Bases

VB100 Vega adaptor base (with link resistor)UB100 Universal adaptor baseVB100S Vega adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVDBS100Vega deep adaptor baseDBS100 Deep adaptor baseVDBS100S Vega deep adaptor base with shorting clipDBS100SDeep adaptor base with shorting clipFireguard P/N FG854001 4 wire detector base

Certificate No: 512d-(cl-4) to EN54-5: 2000 + A1: 2002Certificate No: 928d-(cl-7) to EN 54-5: 2000 + A1: 2002

Certificated Products LPCB Ref. No.

Fireguard FG323-2L Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (Fireguard P/N FG854001 base)

512d/04

FGHD350 Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

928d/01

BasesVB100 Vega adaptor base (with link resistor)UB100 Universal adaptor baseVB100S Vega adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVDBS100Vega deep adaptor baseDBS100 Deep adaptor baseVDBS100S Vega deep adaptor base with shorting clipDBS100SDeep adaptor base with shorting clipFireguard P/N FG854001 4 wire detector base

Page 216: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

206 31 Dec 2012

Firelite by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Honeywell Life Safety Systems, Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 1444 230 300 • Fax: +44 1444 230 888E-mail: [email protected]

Certificate No: 550a to EN 54-7: 2000 + A1: 2002Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 1999Certificate No: 550c to EN 54-5: 2000 + A1: 2002

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.FL/1003 Conventional photoelectric smoke detector

(FL/1000B base)550a/02

FL/1002 Conventional optical/thermal detector (FL/1000B base)

550b/02

Notes: 1. Meets the requirements of EN54-5 at class A1R at pre-set sensitivity.

FL/1005 Conventional Class A1R rate of rise heat detector (FL/1000B base)

550c/03

BasesFL/1000B standard base

Fireonica Co. Ltd2 The Dingle, Wolverhampton WV3 9ET, United KingdomTel: 01902 762 163 • Fax: 0845 299 1039E-mail: [email protected]

Certificate No: 928d-(cl-8) to EN 54-5: 2000 + A1: 2002Certificate No: 928e-(cl-8) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

FOHD350 Analogue addressable Class P heat detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

928d/01

FOSD100 Analogue addressable photoelectric smoke detector lite (VB100, UB100, VB100S, UB100S, VDBS100, DBS100, VDBS100S and DBS100S bases)Note:

1.Meets the requirements of EN 54-7 at the following sensitivity settings: Optical only level 1 - HighOptical only level 2 Optical only level 3 Optical only level 4 - Low

928e/01

BasesVB100 Vega adaptor base (with link resistor)UB100 Universal adaptor baseVB100S Vega adaptor base with shorting clipUB100S Universal adaptor base with shorting clipVDBS100Vega deep adaptor baseDBS100 Deep adaptor baseVDBS100S Vega deep adaptor base with shorting clipDBS100SDeep adaptor base with shorting clip

Page 217: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 207

FIREX Protection System Technology Ltd28-38 Desborough Street, High Wycombe, Bucks, United KingdomTel: +44 (0)1494 601077 • Fax: +44 (0)1494 601011E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 548c-(cl-3) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.FX9103 Conventional heat detector

Class A1R (DZ-03 base)548c/01

FX9103I Intelligent Rate of Rise Heat DetectorClass A1R (DZ-03 base)

548c/02

Bases:DZ-03 Standard detector base

Certificate No: 548d-(cl-3) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.FX9102 Conventional Photoelectric Smoke Detector

(DZ-03 base)548d/01

FX9102I Intelligent Photoelectric Smoke Detector(DZ-03 base)

548d/02

Bases:DZ-03 Standard detector base

Certificate No: 548k to EN 54-12:2002

Beam DetectorsCertificated Products LPCB Ref.

No.FX9105RI Intelligent optical beam detector 548k/01

Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings:

Level 1 - 1.61 dB Level 2 - 2.31dB

Gent By Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300E-mail: [email protected] • Website: www.gent.co.uk

Middle East Sales Enquiries:E-mail: [email protected]

Certificate No: 042bd to EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005Certificate No: 042az to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.17840-01 Conventional optical smoke detector (17800-01, 17800-02, 17801-01, 17801-02 042az/01

Page 218: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

208 31 Dec 2012

Certificated Products LPCB Ref. No.

mounting bases)

S4-715 S-Quad analogue addressable optical smoke detector Standard base with or without S4-FLUSH semi-flush fixing kit)

042bd/01

Note: 1) Meets the requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical

Bases:78200-01NM standard base17800-01 standard base17801-01 standard base with diode17800-02 low profile base17801-02 low profile base with diodeS4-700 Standard baseS4-FLUSH Semi-flush fixing kit

Certificate No: 567b to BS 5445: Part 5: 1977 This certificate is to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). This certificate, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU.Certificate No: 042ak to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 + A2: 2006, EN 54-17: 2005 and EN 54-18: 2005Certificate No: 042be to EN54-5: 2000+A1: 2002, EN54-17: 2005, EN54-18: 2005Certificate No: 042ay to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.S4-780 S-Quad analogue addressable Class P heat detector with sounder (S4-700 Standard

base with or withoutS4-FLUSH semi-flush mounting kit)

042ak/01

Notes: 1) Meets the requirements of EN 54: Part 5 at the following settings:

State 0 - Class A1 State 5 - Class B

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

S4-720-ST-VO S-Quad analogue addressable Class P heat detector with strobe and speech (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit

042ak/02

Note: 1. Meets the requirements of EN 54: Part 5 at the following settings:

State 0 - Class A1State 5 - Class B2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings:High - Continuous 933 HzAlternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs3. Strobe not included in scope of approval.4. Speech function is not approved against Annex C requirements of EN 54-3

S4-780-ST S-Quad analogue addressable Class P heat detector with sounder and strobe(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042ak/03

Notes: 1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1State 5 - Class B2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 HzAlternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs3. Strobe not included in scope of approval.

17850-01 Conventional Class A1 fixed temperature heat detector (17800-01, 17800-02, 17801-01, 17801-02 mounting bases)

042ay/01

17860-01 Conventional Class A1 rate of rise heat detector (17800-01, 17800-02, 17801-01, 17801-02 mounting bases)

042ay/02

Page 219: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 209

Certificated Products LPCB Ref. No.

S4-720 S-Quad analogue addressable Class P heat detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042be/01

Note:Meets the requirement of EN 54: Part 5 at the following settings:

State 0 - Class A1 State 5 - Class B

17850-01 Conventional grade 1 fixed temperature heat detector (17800-01, 17801-01, 17800-02 and 17801-02 bases)

567b/01

Note: This product is certificated to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU.

17860 -01 Conventional grade 1 rate-of-rise heat detector (17800-01, 17801-01, 17800-02 and 17801-02 bases)

567b/02

Note: This product is certificated to a withdrawn standard. Detectors conforming to this standard are not suitable for use within the jurisdiction of the European Union (EU). The certification, to the withdrawn standard, is maintained because detectors meeting the withdrawn standard requirements are still requested by some regulators outside the EU.

Bases:17800-01 standard base17801-01 standard base with diode17800-02 low profile base17801-02 low profile base with diodeS4-700 standard baseS4-FLUSH semi-flush fixing kit

Certificate No: 042am to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and EN 54-18: 2005Certificate No: 042an to EN 54-5: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1:2002 + A2: 2006, EN 54-17: 2005 and EN 54-18: 2005Certificate No: 042bf to EN54-5: 2000+A1: 2002, EN54-7: 2000+A1: 2002+A2: 2006, EN54-17: 2005, EN54-18: 2005

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.S4-711-ST S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector

with strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)042am/02

Notes:1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat

2) The strobe function is not included within the scope of this approval

S4-911 S-Quad analogue addressable dual optical smoke, Class P heat and carbon monoxide multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042am/03

Notes:1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat2) Meets the requirements of EN 54: Part 5 at the following settings:

State 9 - Class A1 heat3) Carbon monoxide detection is not included within the scope of this approval

S4-711-ST-VO S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042an/01

Notes:

Page 220: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

210 31 Dec 2012

Certificated Products LPCB Ref. No.

1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

3) Speech function is not approved against Annex C requirements of EN 54-3

S4-771 S-Quad analogue addressable dual optical smoke and Class P heat multisensor detectorwith sounder (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042an/02

Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

S4-911-ST-VO S-Quad analogue addressable optical smoke, heat and carbon monoxide multisensor detectorwith speech and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042an/03

Notes:1) Meets the requirements of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat2) Meets the requirements of EN 54: Part 5 at the following settings:

State 9 - Class A1 heat3) Meets the requirements of EN 54: Part 3 at the following sounder tone settings:

High - Continuous 933 HzAlternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

4) Carbon monoxide detection, speech and strobe not included within the scope of this approval5) Speech function is not approved against Annex C requirements of EN 54-3

S4-711-VO S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector with speech (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042an/05

Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat

2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

3) Speech function is not approved against Annex C requirements of EN 54-3

S4-770-ST S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector with sounder and strobeStandard base with or without S4-FLUSH semi-flush mounting kit)

042an/06

Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical / Class A1 heat 2) Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3) Strobe not included in scope of approval.

S4-710 S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042bf/01

Note: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat

Page 221: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 211

Certificated Products LPCB Ref. No.

S4-711 S-Quad analogue addressable dual optical smoke and Class P heat multisensor detector (S4-700 Standard base with or without S4-FLUSH semi-flush fixing kit)

042bf/02

Notes: 1) Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:

State 0 - Medium optical / Class A1 heat State 5 - Medium optical / Class B heat State 8 - Delayed medium optical / Class A1 heat

Bases:S4-700 standard baseS4-FLUSH semi-flush fixing kit

Certificate No: 042bh to EN 54-12: 2002 and EN 54-17: 2005

Beam DetectorsCertificated Products LPCB Ref.

No.S4-34740 Analogue addressable optical beam smoke detector with short circuit isolator

( S4-34741-01 and S4-34741-03)042bh/01

Notes:1. The S4-34740 beam sensor pair comprises of an S4-34741 beam transmitter, plus an S4-34742 beam receiver.2. Meets the requirements of EN 54-12 at the following sensitivity settings: States 0, 1: 3.01dB States 2, 3: 1.25dB

Ancillaries:S4-34741-01 beam angle bracketS4-34741-03 beam parallel bracket

GEZE GmbHReinhold-Vöster-Str. 21-29, D-71229 Leonberg, GermanyTel: +49 (0)7152-203-0 • Fax: +49 (0)7152-203-310E-mail: [email protected] • Website: www.geze.com

Certificate No: 928d-(cl-10) to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.GC003 D Conventional non-latching Class P heat detector (GC 150B relay base and GC160 B

base)928d/02

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B

BaseGC160 B Universal adaptor base

Certificate No: 928e-(cl-10) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.GC002 D Conventional non-latching photo smoke detector (GC150 B relay base and GC160 B

base)928e/02

BasesGC150 B Non-latching relay baseGC160 B Universal adaptor base

Page 222: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

212 31 Dec 2012

Global System Technology PlcLion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United KingdomTel: +44 (0)1283 225 478 • Fax: +44 (0)1283 222 039E-mail: [email protected] • Website: www.gst.uk.com

Certificate No: 548k-(cl-5) to EN 54-12:2002

Beam DetectorsCertificated Products LPCB Ref.

No.I-9105R Intelligent Reflective Beam Detector 548k/01

Notes:1) Meets the requirements of EN 54-12 at the following sensitivity settings:

Level 1 - 1.61 dB Level 2 - 2.31 dB

Certificate No: 548c-(cl-5) to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.C9103 Conventional Class A1R heat detector (DZ-03 base) 548c/01I-9103 Intelligent Class A1R heat detector (DZ-03 base) 548c/02

Bases:DZ-03 Standard detector base

Certificate No: 548d-(cl-5) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.C-9102 Conventional Photoelectric Smoke Detector (DZ-03 base) 548d/01I-9102 Intelligent Photoelectric Smoke Detector (DZ-03 base) 548d/02

Bases:DZ-03 Standard detector base

Group 4 Securicor PlcManor Royal, The Manor, Crawley, West Sussex RH10 9UN, United KingdomTel: +44 (0)20 87707000 • Fax: +44 (0)20 87722531Website: www.g4s.com

Certificate No: 548c-(cl-2) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.GS104C Conventional heat detector

Class A1R (DZ-03 base)548c/01

GS104I Intelligent rate of rise heat detectorClass A1R (DZ-03 base)

548c/02

BasesDZ-03 Standard detector base

Page 223: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 213

Certificate No: 548d-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.GS102C Conventional photoelectric smoke detector

(DZ-03 base)548d/01

GS102I Intelligent photoelectric smoke detector(DZ-03 base)

548d/02

BasesDZ-03 Standard detector base

Certificate No: 548k to EN 54-12:2002

Beam DetectorsCertificated Products LPCB Ref.

No.GS105RI Intelligent optical beam detector 548k/01

Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings:

Level 1 - 1.61 dB Level 2 - 2.31dB

Gulf Security Technology Co., Ltd.No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, ChinaTel: +86 0335 8502434 • Fax: +86 0335 8502532E-mail: [email protected] • Website: www.gst.com.cn

Sales Enquiries:Tel: +852 28778566 • Fax: +852 25118699

Tel: +86 (10)64392919 • Fax: +86 (10)64391767

Certificate No: 548c to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.C-9103 Conventional Class A1R heat detector (DZ-03 base) 548c/01I-9103 Intelligent Class A1R Rate of Rise Heat Detector (DZ-03 base) 548c/02

Bases:DZ-03 Standard detector base

Certificate No: 548d to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorCertificated Products LPCB Ref.

No.C-9102 Conventional Photoelectric Smoke Detector (DZ-03 base) 548d/01I-9102 Intelligent Photoelectric Smoke Detector (DZ-03 base) 548d/02

Bases:DZ-03 standard detector base

Certificate No: 548k to EN 54-12: 2002

Page 224: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

214 31 Dec 2012

Beam DetectorsCertificated Products LPCB Ref.

No.I-9105R Intelligent optical beam detector 548k/01

Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings:

Level 1 - 1.61 dB Level 2 - 2.31 dB

HDRGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132E-mail: [email protected] • Website: www.hochikieurope.com

Certificate No: 117f to EN54-7: 2000 + A1: 2002, EN54-5: 2000 + A1: 2002 and CEA 4021: 1999

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.1410010 Intelligent analogue addressable multisensor (YBN-R/3 base) 117f/01

Note: Meets EN 54-5 class A1 and B and EN 54-7 at 3.0%/m sensitivity setting in normal and low power mode.

Certificate No: 117g to EN 54 Part 5: 2000

Point Heat Detectors/SensorsCertificated Products LPCB Ref.

No.1215110 Class A1S conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK

and 1226150) 117g/02

1215120 Class CS conventional fixed temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and 1226150 bases)

117g/03

1217180 Class A1R conventional rate of rise temperature heat detector (YCA-RL/3H2M, YBN-R/6SK and 1226150 bases)

117g/04

1217190 Conventional Class CR rate of rise high temperature heat detector (YBN-R/6SK and 1226150 bases)

117g/06

1410020 Intelligent analogue addressable Class P heat detector (1426010 and 1226110 bases) 117g/09Note: Meets requirements of EN54-5: 2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.

Bases:1226150 Standard base1426010 Standard baseYCA-RL/3H2M Addressable baseYBN-R/6SK Schottky diode base

Certificate No: 117j to EN 54-12: 2002

Beam DetectorsCertificated Products LPCB Ref.

No.1213060 Optical Beam Smoke Detector 117j/01

Note: Certified at a sensitivity setting of 30% obscuration1213080 Conventional 2 wire optical beam smoke detector 117j/03

Notes:1) Approved at sensitivity setting 25% and 50%.2) Approved for use with 1213080 2WI interface kit.

Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006

Page 225: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 215

Point Smoke Detectors/SensorsCertificated Products LPCB Ref.

No.1412110 Intelligent analogue addressable optical smoke detector

(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

358c/03

1412120 Intelligent analogue addressable optical smoke detector(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

358c/04

1212270 Conventional optical smoke detector(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)

358c/05

1212280 Conventional optical smoke detector(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)

358c/06

Bases YBN-R/3 Standard baseYBO-R/SCI Positive switching short circuit isolator baseYBO-BS Sounder baseYBO-BSB Sounder base with BeaconYBN-R/6 Standard baseYBN-R/6SK Standard base with schottky diodeYBO-R/6R Relay baseYBO-R/6RS Relay base latching with schottky diodeYBO-R/6RN Relay base non latchingYBO-R/6PA Protector alarms base

Hochiki America Corporation7051 Village Drive, Buena Park, California 90621, USATel: +1 714 522 2246 • Fax: +1 714 522 2268E-mail: [email protected] • Website: www.hochiki.com

Certificate No: 358d to EN 54-10: 2002 + A1: 2005

Flame DetectorsCertificated Products LPCB Ref.

No.IR3 Conventional IR 3 Flame Detector

(IR-AMB)358d/01

Note: Meets EN 54-10: 2002 at Class 1 onlyIR3-IS Conventional IR 3 Intrinsically Safe Flame Detector 358d/02

Note: Meets EN 54-10: 2002 at Class 1 onlyIR3-EX Conventional IR 3 (Exd) Flameproof Flame Detector

(IR-AMB)358d/03

Note: Meets EN 54-10: 2002 at Class 1 onlyIR2-UV Conventional UV/IR² Flame Detector

(IR-AMB)358d/04

Note: Meets EN 54-10: 2002 at Class 1 onlyIR2-UV-EX Conventional UV/IR 2 (Exd) Flameproof Flame Detector

(IR-AMB)358d/05

Note: Meets EN 54-10: 2002 at Class 1 only

AncillariesIR-AMB Mounting Bracket

Page 226: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

216 31 Dec 2012

Hochiki Corporation246 Tsuruma, Machidia, Tokyo 194-8577, JapanTel: +81 3 3444 4111 • Fax: +81 3 3444 4167E-mail: [email protected] • Website: www.hochiki.co.jp

Certificate No: 117k to EN 54-10: 2002 + A1: 2005

Certificated Products LPCB Ref. No.

DRD-E Conventional Class 1 IR Flame Detector(YBN-R/6SK, YBN-R/6, YBO-R/6R, YBO-R/6RN, YBO-R/6PA, YBO-R/6RS)

117k/01

Bases

YBN-R/6SK Conventional Schottky diode baseYBN-R/6 Conventional standard baseYBO-R/6R Conventional latching relay baseYBO-R/6RN Conventional non-latching relay baseYBO-R/6PA Conventional 2 wire baseYBO-R/6RS Conventional latching relay base with integral Schottky diode

Hochiki Europe (UK) LimitedGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132Website: www.hochikieurope.com

All Enquiries to:Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132

Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j)Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, JapanTel: +81 3 3444 4111 • Fax: +81 3 3444 4167E-mail: [email protected] • Website: www.hochiki.co.jp

Manufacturing at (Certificate Nos. 164, 164g, 164m)Hochiki Europe (UK) Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (01634 260131 • Fax: +44 (0)1634 260132E-mail: [email protected] • Website: www.hochikieurope.com

Manufacturing at (Certificate Nos. 358, 358c)Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, USATel: +1 714 522 2246 • Fax: +1 714 522 2268E-mail: [email protected] • Website: www.hochiki.com

Certificate No: 117g to EN 54 Part 5: 2000

Page 227: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 217

Point Heat Detectors/SensorsCertificated Products LPCB Ref.

No.DCD-1E-IS Class A1 conventional intrinsically safe fixed temperature and rate of rise heat detector

(YBN-R/4IS1 base)117g/01

DFJ-AE3 Class A1S conventional fixed temperature heat detector (YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases)

117g/02

DFJ-AE3 (HFP) Class A1S conventional fixed temperature heat detector (YBN-R/6(HFP) base) 117g/02DFJ-CE3 Class CS conventional fixed temperature heat detector

(YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases)

117g/03

DFJ-CE3 (HFP) Class CS conventional fixed temperature heat detector (YBN-R/6(HFP)base) 117g/03DCD-AE3 Class A1R conventional rate of rise temperature heat detector

(YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases)

117g/04

DCD-AE3 (HFP) Class A1R conventional rate of rise temperature heat detector (YBN-R/6 (HFP)base) 117g/04DCD-AE3M Conventional Class A1R rate of rise temperature heat detector

(YBN-R/6M base)117g/04

DFG-60BLKJ Class A2 conventional fixed temperature water resistant heat detector 117g/05DCD-CE3 CDX Class CR conventional rate of rise high temperature heat detector

(YCA-RL/3H2M 1 , YBN-R6 SK 1 , YBN-R/6 1 YBO-R/6R, YBO-R/6RS, YBO-R/6RN and YBO-R/6PA bases)

117g/06

DCD-CE3(HFP) Class CR conventional rate of rise high temperature heat detector (YBN-R/6(HFP)base) 117g/06DCD-CE3M Conventional Class CR rate of rise high temperature heat detector

(YBN-R/6M base)117g/06

ACB-E Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 and YBO-R/SCI 1 bases)

117g/09

Note: Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.

ACB-E (HFP) Intelligent analogue addressable Class P heat detector (YBN-R/3(HFP) and YBO-R/SCI(HFP) bases).

117g/09

Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.

ACB-EW Weather proof Intelligent Analogue addressable Class P heat detector 117g/10Note: Meets requirements of EN 54-5:2000 for classes A1R, A1S, BR, BS, CR and CS when used with ACB-E protocol and classes A1S, BS and CS when used with ATG-E protocol.

ATJ-E Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBN-R/3(SCI) 1 ,YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)

117g/13

Note: Meets requirements of EN 54-5:2000 for classes A1R, BR and CR.

ATJ-E(HFP) Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBN-R/3(SCI) 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)

117g/13

Note: Meets requirements of EN 54-5:2000 for classes A1R, BR, CR, A1S, BS and CS.

ATJ-E(WHT) Intelligent Analogue addressable Class P heat detector (YBN-R/3 1 , YBN-R/3(SCI) 1 ,YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)

117g/13

Note: Meets requirements of EN 54-5:2000 for classes A1R, BR, CR, A1S, BS and CS.

YBN-R/4IS Conventional Intrinsically Safe Mounting baseYCA-RL/3H2M Addressable baseYBN-R/6SK Schottky diode baseYBN-R/6 Standard baseYBN-R/3 Standard baseYBO-R/SCI Positive Switching Short circuit isolating base YBO-RSCI/NS Negative Switching Short circuit isolating baseYBF-RL/4H3H 2 wire common mounting baseYBF-RL/4H5H 2 wire common mounting baseYBN-R/6M Standard BaseYBO-BSB Base sounder beaconYBO-BS Base sounderYBO-R/6PA Protector alarms base YBO-R/6R Relay baseYBO-R/6RS Relay latching base with Schottky diodeYBO-R/6RN Relay base non-latchingYBN-R/3(SCI) Short circuit Isolating base

Page 228: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

218 31 Dec 2012

All Enquiries to:Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132

Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j)Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, JapanTel: +81 3 3444 4111 • Fax: +81 3 3444 4167

Certificate No: 117j to EN 54-12: 2002

Beam DetectorsCertificated Products LPCB Ref.

No.SRA-ET Optical Beam Smoke Detector 117j/01

Note: 1) Certified at sensitivity settings 30% obscuration

SRA-ET (HFP) Optical Beam Smoke Detector 117j/01Note: 1) Certified at sensitivity settings 30% obscuration

SPC-E Conventional 4 wire optical beam smoke detector 117j/02Notes:1) Approved at sensitivity setting 25% and 50%

SPC-ET Conventional 2 wire optical beam smoke detector 117j/03Notes:1) Approved at sensitivity setting 25% and 50%2) Approved for use with SPC-ET2WI interface kit

SPC-ET(HFP) Conventional 2 wire optical bem smoke detector. 117j/03Notes:1) Approved at sensitivity setting 25% and 50%2) Approved for use with SPC-ET2WI interface kit

All Enquiries to:Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260131 • Fax: +44 (0)1634 260132

Manufacturing at (Certificate Nos. 117, 117f, 117g, 117h, 117j)Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, JapanTel: +81 3 3444 4111 • Fax: +81 3 3444 4167

Certificate No: 117f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 1999Certificate No: 928m-(cl-7) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.ACA-E Intelligent Analogue addressable multisensor (YBN-R/3 base) 117f/01

Note: Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal and low power mode.

ACA-E (HFP) Intelligent analogue addressable multisensor (YBN-R/3(HFP) base) 117f/01Note: Meets EN 54-5 class A1 and B and EN 54: Part 7 at 3.0%/m sensitivity setting in normal and low power mode.

ACC-E Intelligent Analogue addressable multi-criteria detector (YBN-R/3 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)

117f/02

Note: Certificated at the following modes:

Page 229: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 219

Certificated Products LPCB Ref. No.

Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivityMode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C

ACC-E(HFP) Intelligent Analogue addressable multi-criteria detector(YBN-R/3(HFP), YBO-R/SCI, YBO-BS and YBO-BSB bases)

117f/02

Note: Certificated at the following modes:Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivityMode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C

ACC-E(WHT) Intelligent Analogue addressable multi-criteria detector (YBN-R/3 1 , YBO-R/SCI 1 , YBO-BS 1 and YBO-BSB 1 bases)

117f/02

Note: Certificated at the following modes:Mode 0 - Thermally enhanced smoke detector at 2% and 4.5% sensitivityMode 1 - Optical smoke detector at 2% and 4.5% sensitivity Mode 2 - Fixed temperature heat detector at class A1 & C

RMD-E Wireless multi-criteria detector (RSM-WDB base) 928m/01Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity setting3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR2032A (3 Vdc) - secondary battery

Bases:YBN-R/3 baseYBN-R/3 Standard baseYBN-R/2NA baseYBO-R/SCI Positive switching short circuit isolator baseYBN-R/4IS intrinsically safe mounting base1

YCA-RL/3H2 addressable base YCA-RL/5H2 master addressable baseAMU-B2 addressable baseAMU-MB master addressable baseYBC-RL/4H5 baseYBF-RL/3J slave baseYBF-RL/4H5 base1

YBK-RL/4H1A base1

YBK-RL/4H2 base1

YCA-RL/3H2M addressable baseYBN-R/6SK Schottky diode baseYBN-R/6 Standard baseYBN-R/4 base1

YBN-R/6M Standard baseYBO-BS Sounder baseYBO-BSB Sounder base with BeaconYBO-R/5 base1

YBN-R/4M base1

YBO-R/5M base1

YBO-R/6R Relay baseYBO-R/6RS Relay base latching with schottky diodeYBO-R/6RN Relay base non latchingYBO-R/6PA Protector alarms baseYBO-RSCI/NS Negative Switching Short circuit isolating baseYBF-RL/4H3H 2 wire mounting baseYBF-RL/4H5H 2 wire mounting baseRSM-WDB - Wireless Adaptor Base

1 Bases manufactured by Hochiki Europe. All other bases manufactured by Hochiki Corporation.LP denotes detector/base combination is approved in low power mode also.

Page 230: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

220 31 Dec 2012

All Enquiries to:Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132

Manufacturing at (Certificate Nos 117, 117f, 117g, 117h, 117j)Hochiki Corporation, 141-1 Maehara Ejiri, Kakuda-shi, Miyagi 971-15, JapanTel: +81 3 3444 4111 • Fax: +81 3 3444 4167E-mail: [email protected] • Website: www.hochiki.co.jp

Manufacturing at (Certificate Nos 164, 164g, 164m)Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132E-mail: sales @hochikieurope.com • Website: www.hochikieurope.com

Manufacturing at (Certificate Nos 358, 358c)Hochiki America Corporation, 7051 Village Drive, Buena Park, California 90621, USATel: +1 714 522 2246 • Fax: +1 714 522 2268E-mail: [email protected] • Website: www.hochiki.com

Certificate No: 117h to EN 54-7: 2000Certificate No: 164g to EN 54-7: 2000 + A1: 2002Certificate No: 358c to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke Detectors/SensorsCertificated Products LPCB Ref.

No.SLV-E(J) Conventional photoelectric smoke detector (YBN-R/4C1 base) 117h/01ALK-E(J) Analogue addressable photoelectric smoke detector

(YBN-R/2NA,YBO-R/SCI,YBO-BS & YBO-BSB bases)117h/02

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

ALN-E(HFP) Intelligent Analogue Addressable Optical Smoke Detector (YBN-R/3(SCI), YBN-R/3, YBO-R/SCI, YBN-R/2NA, YBO-BS & YBO-BSB bases)

117h/03

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

SLR-E-IS Conventional photoelectric smoke detector (YBN-R/4IS base) 164g/02SLK-EN Conventional photoelectric smoke detector (YBF-RL/4H3, YBF-RL/4H5, YBF-RL/4H5H

bases)164g/03

ALK-E Intelligent Analogue addressable optical smoke detector(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)

358c/03

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

ALK-E (WHT) Intelligent Analogue addressable optical smoke detector (White)(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)

358c/03

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

ALK-E(HFP) Intelligent analogue addressable optical smoke detector (White) (YBN-R/3(HFP), YBO/R3SCI(HFP), YBO/BS & YBO-BSB bases)

358c/03

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and lower power modes

ALK-EM Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)

358c/03

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

ALG-EN Intelligent Analogue addressable optical smoke detector(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)

358c/04

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and

Page 231: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 221

Certificated Products LPCB Ref. No.

in normal and low power modes

ALG-EN (BLK) Intelligent Analogue addressable optical smoke detector(Black)(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)

358c/04

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

ALG-EN (WHT) Intelligent Analogue addressable optical smoke detector(White)(YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)

358c/04

Note: Meets the requirements of EN54-7 in low and high sensitivity settings andin normal and low power modes

ALG-ENM Intelligent analogue addressable optical smoke detector (YBN-R/3,YBO-R/SCI,YBO-BS & YBO-BSB bases)

358c/04

Note: Meets the requirements of EN54-7 in low and high sensitivity settings and in normal and low power modes

SLV-E3 Conventional optical smoke detector(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)

358c/05

SLV-E3 (WHT) Conventional optical smoke detector(White)(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)

358c/05

SLV-E3(HFP) Conventional optical smoke detector (White) (YBN-R/6(HFP) bases)

358c/05

SLR-E3N Conventional optical smoke detector(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)

358c/06

SLR-E3N(BLK) Conventional optical smoke detector(Black)(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)

358c/06

SLR-E3N(WHT) Conventional optical smoke detector(White)(YBN-R/6,YBN-R/6SK,YBO-R/6R,YBO-R/6RS,YBO-R/6RN & YBO-R/6PA bases)

358c/06

Bases YBO-R/SCI Positive switching short circuit isolator baseYBO-BS Sounder baseYBO-BSB Sounder base with BeaconYBO-R/6R Relay baseYBO-R/6RS Relay base latching with schottky diodeYBO-R/6RN Relay base non latchingYBO-R/6PA Protector alarms baseYBN-R/3 Standard baseYBN-R/2NA Standard baseYBN-R/6 Standard baseYBN-R/6SK Standard base with schottlky diodeYBO-BS Sounder baseYBO-BSB Sounder base with BeaconYBN-R/3(SCI) Short Circuit Isolator BaseYBN-R/3 Addressable detector base

All Enquiries to:Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132

Manufacturing at (Certificate Nos 164, 164g, 164m)Hochiki Europe UK Limited, Grosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0) 1634 260131 • Fax: +44 (0) 1634 260132E-mail: [email protected] • Website: www.hochikieurope.com

Certificate No: 164m to EN54-10:2002

Page 232: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

222 31 Dec 2012

Flame DetectorsCertificated Products LPCB Ref.

No.IFD-E Conventional IR 3 Flame detector 164m/01

Note: Meets EN 54-10: 2002 at Class 1 onlyIFD-E(IS) Conventional IR 3 Intrinsically Safe Flame Detector 164m/02

Note: Meets EN 54-10: 2002 at Class 1 onlyIFD-E(EXD) Conventional IR 3 (Exd) Flameproof Flame Detector 164m/03

Note: Meets EN 54-10: 2002 at Class 1 only

Certificate No: 928k-(cl-7) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.ROD-E Wireless optical smoke detector (RSM-WDB base) 928k/01

Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR2032A (3 Vdc) - secondary battery

Bases:RSM-WDB - Wireless Adaptor Base

Certificate No: 928j-(cl-7) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Heat DetectorsCertificated Products LPCB Ref.

No.RHD-E Wireless heat detector (RSM-WDB base) 928j/01

Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR2032A (3 Vdc) - secondary battery

Base:RSM-WDB - Wireless Adaptor Base

Honeywell Automation (I) Pvt. Ltd53, 54, 55 Hadapasar Indl. Estate, Hadapsar, Pune-411013, IndiaTel: +91 020 66780200 • Fax: +91 020 66780172E-mail: [email protected] • Website: www.myhoneywell.com

Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.TC840MES-yy Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1,

B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550b/05

TC840MEIS-yy Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes:

550e/02

Page 233: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 223

Certificated Products LPCB Ref. No.

1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

Bases:1450614-007 Standard analogue detector baseB501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Certificate No: 550c to EN54-5: 2000 + A1: 2002Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.TC808ES1028-yy Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1,

B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/06

TC808ES1002-yy Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/07

TC808EIS1028-yy Analogue addressable class A1R rate of rise heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550f/01

TC808EIS1002-yy Analogue addressable class A1S fixed temperature heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550f/02

Bases:14506414-007 Standard analogue detector baseB501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Certificate No: 550a to EN54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.TC806ES1012-yy Analogue addressable optical smoke detector

(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity

550a/04

TC806EIS1012-yy Analogue addressable optical smoke detector with short circuit isolator(B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity

550d/01

Page 234: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

224 31 Dec 2012

Bases:14506414-007 standard analogue detector baseB501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Honeywell Control Systems LimitedHoneywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United KingdomTel: +44 (0)1344 655609 • Fax: +44 (0)1344 655474Website: www.honeywellbuildingsolutions.co.uk

Certificate No: 199p-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003Certificate No: 199aa-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005Certificate No: 199t-(cl-1) to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021:2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.TC840MFEIS Analogue addressable photo-thermal-IR multi-criteria smoke sensor

with short circuit isolator (B501AP, B524HTR & B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000& CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/01

TC840MEIS Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000& CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/02

TC840MFES Analogue addressable photo-thermal-IR multi-criteria sensor(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000& CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199p/06

TC840MES Analogue addressable photo-thermal multi-criteria sensor(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000& CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199p/07

TC850E1009-yy Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases)

199t/01

Notes: 1.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

2.) Certified at the following settings: -

Normal Mode: Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021 Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R

Nuisance Environment Applications: Application 0,Alarm Level 4 LPS1279 & CEA 4021 Application 1,Alarm Level 5 EN54-5 Class A1R, EN54-7

Page 235: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 225

Certificated Products LPCB Ref. No.

& CEA 4021 Application 2,Alarm Level 4 or 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 3,Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021

Application 4,Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 5,Alarm Level 5 EN54-7 & CEA 4021 Application 6,Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 7,Alarm Level 5 EN54-5 Class A1R, LPS1279 & CEA 4021

Bases:

B501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005

Beam DetectorsCertificated Products LPCB Ref.

No.TC847A1004EURIS Analogue optical beam detector with self test facility and short circuit isolator feature 199w/02

Note: 1. Meets the requirements of BS EN54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2

Ancillaries:

RTS151-KEY Remote test Station 6500 - LRK/BEAMLRK Long Range Kit6500 - MMK/BEAMMMK Multi-Mounting Kit6500 - SMK/BEAMSMK Surface Mounting Kit

Certificate No: 199n to EN 54-5: 2000 + A1: 2002Certificate No: 199n-(cl-1) to EN 54-5: 2000 + A1: 2002Certificate No: 199ac-(cl-1) to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.TC808EIS1002 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator

(B501AP, B524HTR & B524RTE bases)199ac/01

TC808EIS1051 Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases)

199ac/02

TC808EIS1028 Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases)

199ac/03

TC808ES1028 Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)

199n/15

TC808ES1051 Analogue addressable class BS fixed temperature heat sensor(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)

199n/16

TC808ES1002 Analogue addressable class A1S fixed temperature heat sensor(B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)

199n/17

Bases:SIGI-IBS Isolator baseSIGA-SB Standard baseSIGA-SB4 Standard base with trim skirtSIGA-RB Relay baseB501 analogue detector baseB501AP intelligent sensor base

Page 236: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

226 31 Dec 2012

B501DG analogue deep baseB524IEFT analogue short circuit isolator baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Certificate No: 199m to EN 54-7: 2000 + A1: 2002Certificate No: 118h to EN 54-7: 2000Certificate No: 199m-(cl-1) to EN 54-7: 2000 + A1: 2002Certificate No: 199ab-(cl-1) to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005

Point Smoke Detectors/SensorsCertificated Products LPCB Ref.

No.TC846A1005 Analogue addressable laser optical detector (B501, B501DG & B524IEFT bases) 118h/01

Note: meets requirements of EN 54 Part 7 at sensitivity settings of 7 to 9 inclusive

TC806EIS1012 Analogue addressable optical smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases)

199ab/01

Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

TC842B1007 AE Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP bases)

199m/07

Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings

TC806ES1012 Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)

199m/10

Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

Bases:B501 Analogue detector baseB501DG Analogue deep baseB501AP Intelligent detector base B524IEFT Analogue short circuit isolator baseB524IEFT-1 Analogue short circuit isolator baseB524HTR Heater BaseB524RTE Latching relay base SIGI-IBS Isolator baseSIGA-SB Standard BaseSIGA-SB4 Standard base with trim skirtSIGA-RB Relay baseSIGA-RB4 Relay base with trim skirt

Honeywell Control Systems LtdHoneywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United KingdomTel: 01344 655609 • Fax: 01344 655474Website: www.honeywellbuildingsolutions.co.uk

Certificate No: 262s-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA 4021: 2003Certificate No: 262t-(cl-2) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.XLS-IPHSI Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke

detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 & SIGA-AB4G bases)

262s/01

Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases.

Page 237: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 227

Certificated Products LPCB Ref. No.

XLS-PHSI Intelligent analogue addressable thermally enhanced photoelectric smoke detector(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262s/02

Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases.

XLS-ISI Intelligent analogue addressable ionisation smoke detector SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262t/01

Notes:1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases

XLS-PSI Intelligent analogue addressable photoelectric smoke detector SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262t/02

Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases

Bases:

SIGI-IBS Isolator baseSIGA-SB Standard baseSIGA-SB4 Standard base with trim skirtSIGA-RB Relay baseSIGA-RB4 Relay base with trim skirtSIGA-IB Isolator BaseSIGA-IB4 Isolator base with 4 inch mounting adaptorsSIGA-AB4G Sounder base

Accessories:

SIGA-LED Indicator

Certificate No: 262u-(cl-2) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.XLS-HRSI Intelligent analogue addressable Class A1 & A2R rate of rise heat detector

(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262u/02

Notes: 1. The SIGA-LED indicator is also approved for use with the SIGA-SB and SIGA-SB4 bases

Bases:

SIGI-IBS Isolator baseSIGA-SB Standard baseSIGA -SB4 Standard base with trim skirtSIGA -RB Relay baseSIGA -RB4 Relay base with trim skirtSIGA-IB Isolator BaseSIGA-IB4 Isolator base with 4 inch mounting adaptorsSIGA-AB4G Sounder base

Accessories:

SIGA-LED Indicator

Page 238: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

228 31 Dec 2012

Honeywell Life Safety Systems (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300E-mail: [email protected] • Website: www.gent.co.uk

Certificate No: 524c-(cl-1) to EN 54-20:2006

Aspirating Smoke DetectorsCertificated Products LPCB Ref.

No.ALL-SPEC ASD 524c/01

Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1 HW.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations (Class A, Class B and Class C): ALL-SPECx (standard version, no bargraph display, 1 alarm, not available for

networking) ALL-SPECx-FR (deep freeze version, no bargraph display, 1 alarm, not

available for networking ) ALL-SPECx-SL (silent version, no bargraph display, 1 alarm, not available for

networking) X=detector 1 or 23. The approved detector must incorporate one or two of the following detector

modules: ASD-TP-001-L (standard version, sensitivity of 0.015%/m) ASD -TP-001-L-F (deep freeze version, sensitivity of 0.015%/m) ASD -TP-01-L (standard version, sensitivity of 0.10%/m) ASD -TP-01-L-F (deep freeze version, sensitivity of 0.10%/m) ASD -TP-05-L (standard version, sensitivity of 0.50%/m) ASD -TP-05-L-F (deep freeze version, sensitivity of 0.50%/m)

X=detector 1 or 2

HI-SPEC ASD 524c/03Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1 HW.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations (Class A, Class B and Class C): HI-SPECx (standard version, bargraph display, 3 alarms, prepared for

networking) HI-SPECx-FR (deep freeze version, bargraph display, 3 alarms, prepared for

networking) HI-SPECx -SL (silent version, bargraph display, 3 alarms, prepared for

networking)

3. The approved detector must incorporate one or two of the following detector modules: ASD-TT-001-L (standard version, sensitivity of 0.015%/m) ASD -TT-001-L-F (deep freeze version, sensitivity of 0.015%/m) ASD -TT-01-L (standard version, sensitivity of 0.10%/m) ASD -TT-01-L-F (deep freeze version, sensitivity of 0.10%/m) ASD -TT-05-L (standard version, sensitivity of 0.50%/m)

Page 239: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 229

Certificated Products LPCB Ref. No.

ASD -TT-05-L-F (deep freeze version, sensitivity of 0.50%/m)

COMPACT ASD 524c/04Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1 HW.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations, sensitivity of 0.50%/m (Class A, Class B and Class C): ASD-CM (version with 2 stages of alarm) ASD-CM2 (version with 2 stages of alarm, ROOM IDENT)

Horing LIH Industrial Co LtdNo. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROCTel: +886 2 22487599 • Fax: +886 2 22407752

Certificate No: 506a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.AHS-871 Conventional photoelectric smoke detector (AHMB-L mounting base) 506a/01AH-0311-2 (2 wire) Conventional photoelectric smoke detector (AHMB-031 Base) 506a/02AH-0311-3 (3 wire) Conventional photoelectric smoke detector (AHMB-031 Base) 506a/03AH-0311-4 (4 wire) Conventional photoelectric smoke detector (AHMB-031 Base) 506a/04Q01-2 Conventional 2-wire optical smoke detector

(AHMB-061-2 and AHMB-071-2 bases )506a/05

Q01-3 Conventional 3-wire optical smoke detector with remote(AHMB-061-3 and AHMB-071-3 bases )

506a/06

Q01-4 Conventional 4-wire optical smoke detector with relay output(AHMB-061-4 and AHMB-071-4 bases)

506a/07

Bases:AHMB-031 mounting baseAHMB-L mounting baseAHMB-061-2 Standard baseAHMB-061-3 Standard baseAHMB-061-4 Standard baseAHMB-071-2 Base UnitAHMB-071-3 Base UnitAHMB-071-4 base Unit

Certificate No: 506b to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-5: 2000 + A1: 2002 and CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.AH-0315-2 (2 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/01AH-0315-3 (3 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/02AH-0315-4 (4 wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/03Q05-2 Conventional 2-wire optical smoke and class A2 heat detector

(AHMB-061-2 and AHMB-071-2 bases)506b/04

Q05-3 Conventional 3-wire optical smoke and class A2 heat detector with remote LED (AHMB-061-3 and AHMB-071-3 bases)

506b/05

Q05-4 Conventional 4-wire optical smoke and class A2 heat detector with relay output (AHMB- 506b/06

Page 240: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

230 31 Dec 2012

Certificated Products LPCB Ref. No.

061-4 and AHMB-071-4 bases)

Bases:AHMB-031 mounting baseAHMB-061-2 Standard baseAHMB-061-3 Standard baseAHMB-061-4 Standard baseAHMB-071-2 Base UnitAHMB-071-3 Base UnitAHMB-071-4 base Unit

Certificate No: 506c to EN 54-5: 2000 + A1: 2002

Point Heat DetectorCertificated Products LPCB Ref.

No.AH-0316-2 (2 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-

031 Base)506c/01

AH-0316-3 (3 wire) Conventional three wire rate of rise and fixed temperature heat detector (AHMB-031 Base)

506c/02

AH-0316-4 (4 wire) Conventional four wire rate of rise and fixed temperature heat detector (AHMB-031 Base)

506c/03

Q06-2 Conventional 2-wire Class A2 heat detector(AHMB-061-2 and AHMB-071-2 bases)

506c/04

Q06-3 Conventional 3-wire Class A2 heat detector with remote LED(AHMB-061-3 and AHMB-071-3 bases)

506c/05

Q06-4 Conventional 4-wire Class A2 heat detector with relay output(AHMB-061-4 and AHMB-071-4 bases)

506c/06

Bases:AHMB-031 mounting baseAHMB-061-2 Standard baseAHMB-061-3 Standard baseAHMB-061-4 Standard baseAHMB-071-2 Base UnitAHMB-071-3 Base UnitAHMB-071-4 base Unit

Certificate No: 506f to EN 14604: 2005

Smoke DetectorsCertificated Products LPCB Ref.

No.NQ9S Single Station Smoke Detector 506f/01

Industrial Scientific OldhamRue Orfila - ZI Est - BP417, 62027 Arras Cedex, FranceTel: +33 321 60 8130 • Fax: +33 321 60 8000E-mail: [email protected] • Website: www.groupoldham.com/site_en/fra

Certificate No: 911a-(cl-3) to EN54-10: 2002 + A1: 2005

Flame DetectorsCertificated Products LPCB Ref.

No.40/40R Conventional Class 1 single IR flame detector

Notes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40R-abcde):

a. Wiring options - 1 to 5

911a/01

Page 241: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 231

Certificated Products LPCB Ref. No.

b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

40/40I Conventional Class 1 triple IR (IR3) flame detectorNotes: 1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters or numbers following the standard model number outlined respectively below e.g.40/40I-abcde)

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/02

40/40M Conventional Class 1 quad IR flame detectorNotes: 1. Meets the requirements of EN 54-10: 2002 Class 1at sensitivity setting 2 (default) only. 2. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40M-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/03

40/40L4B Conventional Class 2 UV/IR flame detectorNotes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L4B-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/04

40/40L4 Conventional Class 2 UV/IR flame detectorNotes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L4-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/05

40/40LB Conventional Class 2 UV/IR flame detectorNotes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40LB-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/06

40/40L Conventional Class 2 UV/IR flame detectorNotes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º C

911a/07

Page 242: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

232 31 Dec 2012

Certificated Products LPCB Ref. No.

c. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

40/40UB Conventional Class 2 UV flame detectorNotes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40UB-abcde):

a. Wiring options – 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/08

40/40U Conventional Class 2 UV flame detectorNotes: 1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40U-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75º C ; 2=85º Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/09

INIM Electronics s.r.l.Via Fosso Antico - Loc, Centobuchi, 63033 Monteprandone (AP), ItalyTel: +39 0735 705007 • Fax: +39 0735 704912E-mail: [email protected] • Website: www.inim.biz

Certificate No: 991d to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 991c to EN 54-7: 2000 + A1:2002 + A2:2006

Smoke DetectorsCertificated Products LPCB Ref.

No.ID100 Conventional optical smoke detector

(EB0010 and EB0020 bases).991c/01

Note:1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.

ED100 Intelligent analogue addressable optical smoke detector with short circuit isolator (EB0010 and EB0020 bases).

991d/01

Note:1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.

Bases:

EB0010 Standard base EB0020 Relay base

Certificate No: 991f to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005Certificate No: 991e to EN 54-5: 2000 + A1:2002

Heat DetectorsCertificated Products LPCB Ref.

No.ID200 Conventional class P heat detector

(EB0010 and EB0020 bases).991e/01

Note:1) Meets the requirements of EN54-5:2000 at class A1R & class B.

Page 243: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 233

Certificated Products LPCB Ref. No.

ED200 Intelligent analogue addressable class P heat detector with short circuit isolator (EB0010 and EB0020 bases).

991f/01

Note:1) Meets the requirements of EN54-5:2000 at class A1R & class B.

Bases:

EB0010 Standard base EB0020 Relay base

Certificate No: 991b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005Certificate No: 991a to EN 54-5: 2000 + A1:2002, EN 54-7: 2000 + A1:2002 + A2:2006 and CEA4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.ID300 Conventional multi-criteria detector (EB0010 and EB0020 bases). 991a/01

Note:1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities.2) Meets the requirements of EN 54-5:2000 at class A1R & class B.

ED300 Intelligent analogue addressable multi-criteria detector with short circuit isolator (EB0010 and EB0020 bases).

991b/01

Note:1) Meets EN 54-7:2000 with low, medium-low, medium-high and high sensitivities. 2) Meets the requirements of EN 54-5:2000 at class A1R & class B.

Bases:

EB0010 Standard base EB0020 Relay base

Intelligent Safety & Security Technology Ltd.6-7 Ludgate Square,, London EC4M 7AS, United KingdomTel: +44 845 116 2945E-mail: [email protected] • Website: www.isst-uk.com

Certificate No: 512a-(cl-6) to EN54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.CS-01 Conventional 2 wire photoelectric smoke detector with remote LED output (CB-D2 base) 512a/02

Base:CB-D2 4-wire detector base

Certificate No: 512b-(cl-3) to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA4021: 2003

Multi-Sensor/Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.CSH-01 Conventional 2 wire photoelectric smoke and heat detector with remote LED output (CB-

D2 base)512b/02

Base:

Page 244: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

234 31 Dec 2012

CB-D2 4-wire detector base

Certificate No: 512d-(cl-6) to EN54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.CH-01 Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector

with LED output (CB-D2 base)512d/04

Base:CB-D2 4-wire detector base

Kidde Products LtdThame Park Road, Thame, Oxfordshire OX9 3RT, United KingdomTel: +44 (0)1844 265003 • Fax: +44 (0)1844 265156E-mail: [email protected] • Website: www.kfp.co.uk

Certificate No: 404c to EN54-20: 2006

Aspirating Smoke DetectorsCertificated Products LPCB Ref.

No.Senator 25 High sensitivity aspirating smoke detector 404c/01

Notes:1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be

supplied with power from a power supply complying with EN54-4.2) The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.- The device is approved for sensitivity Classes A, B and C for sensitivities up

to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Senator 100 High sensitivity aspirating smoke detector 404c/02

Notes:1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be

supplied with power from a power supply complying with EN54-4.2) The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.- The device is approved for sensitivity Classes A, B and C for sensitivities up

to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Senator 200 High sensitivity aspirating smoke standard detector (Senator 200 Stand Alone Command Module Ancillary)

404c/03

Notes:1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be

supplied with power from a power supply complying with EN54-4.2) The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.- The device is approved for sensitivity Classes A, B and C for sensitivities up

to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Senator 200 High sensitivity aspirating smoke command module detector 404c/04Notes:1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be

supplied with power from a power supply complying with EN54-4.2) The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.- The device is approved for sensitivity Classes A, B and C for sensitivities up

to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Page 245: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 235

Certificated Products LPCB Ref. No.

Senator 200 High sensitivity aspirating minimum display version smoke detector (Senator 200 Stand Alone Command Module Ancillary)

404c/05

Notes:1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be

supplied with power from a power supply complying with EN54-4.2) The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.- The device is approved for sensitivity Classes A, B and C for sensitivities up

to 0.62%/m, 1.95%/m and 4.65%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Ancillaries:Senator 200 Stand Alone Command Module

Kidde Products Ltd, trading as AirSense TechnologyUnit 1, Caxton Place, Caxton Way, Stevenage, Hertfordshire SG1 2UG, United KingdomTel: +44 (0)1462 751296 • Fax: +44 (0)1462 729137E-mail: [email protected] • Website: www.airsense.co.uk/airsense

Certificate No: 404c to EN54-20: 2006

Certificated Products LPCB Ref. No.

Stratos Micra 25 High sensitivity aspirating smoke detector 404c/01Notes:1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4.2) The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Stratos Micra 100 High sensitivity aspirating smoke detector 404c/02Notes:1) For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN54-4.2) The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.3) The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Stratos HSSD 2 High sensitivity aspirating smoke standard detector (Stratos HSSD 2 Stand Alone Command Module Ancillary)

404c/03

Notes: The approval of the detectors is conditional upon the following requirements:

1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4.2. The approval of the detector is conditional upon the following requirements:

Design, installation and commissioning are performed in accordance with the system design manual and instructions.

The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Stratos HSSD 2 High sensitivity aspirating command module smoke detector 404c/04Notes: The approval of the detectors is conditional upon the following requirements:

1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4.2. The approval of the detector is conditional upon the following requirements:

Design, installation and commissioning are performed in accordance with the system design manual and instructions.

The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Page 246: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

236 31 Dec 2012

Certificated Products LPCB Ref. No.

Stratos HSSD 2 High sensitivity aspirating minimum display version smoke detector (Stratos HSSD 2 Stand Alone Command Module Ancillary)

404c/05

Notes:The approval of the detectors is conditional upon the following requirements:

1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4.2. The approval of the detector is conditional upon the following requirements:

Design, installation and commissioning are performed in accordance with the system design manual and instructions.

The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.62%/m, 1.95%/m and 4.65%/m respectively.. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Stratos Nano High sensitivity aspirating standard smoke detector 1, 2, 3 404c/06Notes:The approval of the detectors is conditional upon the following requirements:

1. For compliance with Clause 5.10 of EN54-20:2006, the detector shall be supplied with power from a power supply complying with EN 54-4.2. The approval of the detector is conditional upon the following requirements:

Design, installation and commissioning are performed in accordance with the system design manual and instructions.

The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.80%/m, 1.66%/m and 7.54%/m respectively. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

Ancillaries:Stratos HSSD 2 Stand Alone Command Module

Labor Strauss Sicherungsanlagenbau GmbHWiegelestrasse 36, A-1231 Vienna, AustriaTel: +43 1 52114-44 • Fax: +43 1 52114-27E-mail: [email protected] • Website: www.lst.at

Certificate No: 928e-(cl-11) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.FC650/O Conventional Photo Detector

(FC600/B, FC600/BR and FC600/BRD bases)928e/02

BasesFC600/B Universal adaptor baseFC600/BR Universal adaptor base with resistorFC600/BRD Universal adaptor base with resistor and Schottky diode

Certificate No: 928d-(cl-11) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.FC650/TDIFF/57 Conventional Class A1R Thermal Detector

(FC600/B, FC600/BR and FC600/BRD bases)928d/02

FC650/TMAX/78 Conventional Class B Thermal Detector(FC600/B, FC600/BR and FC600/BRD bases)

928d/02

BasesFC600/B Universal adaptor baseFC600/BR Universal adaptor base with resistorFC600/BRD Universal adaptor base with resistor and Schottky diode

Page 247: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 237

Lichfield Fire & Safety Equipment Co. Ltd (LIFECO)Unit 8, Calibre Industrial Park, Laches Close, Four Ashes, Wolverhampton WV10 7DZ, United KingdomTel: +44 (0) 1902 798 706 • Fax: +44 (0) 1902 798 679E-mail: [email protected] • Website: www.lifeco-uk.com

Certificate No: 506c-(cl-1) to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.LFHD60 wire) Conventional Class A2 rate of rise and fixed temperature heat detector (AHMB-031

base)506c/01

Bases:AHMB-031 mounting base

Certificate No: 506a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Photoelectric Smoke DetectorsCertificated Products LPCB Ref.

No.LF-PE-4100 LF-PE-4100 Conventional photoelectric smoke detector (AHMB-L base) 506a/01

Bases:AHMB-L mounting base

Mavili Elektronik Ticaret Ve Sanayi A.S.Bostanci Dudullu Yolu, Kutup Sok, No. 29 Y Dudullu - Umraniye, Istanbul TR 34775, TurkeyTel: +90 216 4664 505 • Fax: +90 216 4664 510E-mail: [email protected] • Website: www.mavigard.com

Certificate No: 926a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.MG-9100 Intelligent analogue addressable system photoelectric smoke detector (MG-3510 base) 926a/01

Bases:MG-3510 standard mounting base

Certificate No: 926b to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.MG-9300 Intelligent analogue addressable system class A1R rate of rise heat detector (MG-3510

base)926b/01

Bases:MG-3510 standard mounting base

Certificate No: 926c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Page 248: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

238 31 Dec 2012

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.MG-9400 Intelligent analogue addressable system class A1R multisensor detector (MG-3510 base) 926c/01

Bases:MG-3510 standard mounting base

Morley-IAS Fire Systems By HoneywellHoneywell Fire Systems, BSEL Tech Park, Floor 6,Sector 30A, Opposite Vshi Station, Vashi, New Mumbai, IndiaTel: +91 022 67122427 • Fax: +91 022 67122422E-mail: [email protected] • Website: www.myhoneywell.com

Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.MI-PTSE Analogue optical/thermal smoke & heat detector (MI-B501 base) 550b/03

Notes:1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 52) Meets the requirements of EN 54-5:2000 at Class A1R

MI-PTIR-S2-yy Analogue addressable photo-thermal-IR multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550b/04

MI-PTSE-S2-yy Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550b/05

MI-PTIR-S2I-yy Analogue addressable photo-thermal-IR multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases)Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550e/01

MI-PTSE-S2I-yy Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550e/02

Bases:MI-B501 Standard analogue detector baseB501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Page 249: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 239

Certificate No: 550c to EN 54-5: 2000 + A1: 2002Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.MI-FHSE Analogue addressable Class A1S fixed temperature heat detector (MI-B501 base) 550c/04MI-RHSE Analogue addressable Class A1R high temperature rate of rise heat detector (MI-B501

base)550c/05

MI-RHSE-S2-yy Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/06

MI-FHSE-S2-yy Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/07

MI-RHSE-S2I-yy Analogue addressable class A1R rate of rise heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550f/01

MI-FHSE-S2I-yy Analogue addressable class A1S fixed temperature heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550f/02

Bases:MI-B501 Standard analogue detector baseB501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.MI-PSE Analogue addressable optical smoke detector (MI-B501 base) 550a/03

Note: Meets EN 54-7 with low, medium and high sensitivity settingsMI-PSE-S2-yy Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR

and B524RTE bases) Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity

550a/04

MI-PSE-S2I-yy Analogue addressable optical smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity

550d/01

Bases:MI-B501 standard analogue detector baseB501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Page 250: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

240 31 Dec 2012

Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.morley-ias.co.uk

Certificate No: 199n to EN 54-5: 2000 + A1: 2002Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.MI-FHSE-S2I Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator

(B501AP, B524HTR and B524RTE bases)199ac/01

MI-HTSE-S2I Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases)

199ac/02

MI-RHSE-S2I Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases)

199ac/03

HRZ-1005T Class A2S conventional fixed temperature heat detector(HRZ-1000BSD base)

199n/10

HRZ-1004T Class BS conventional fixed temperature heat detector(HRZ-1000BSD base)

199n/11

HRZ-1005 Class A1R conventional rate of rise heat detector(HRZ-1000BSD base)

199n/12

MI-RHSE-S2 Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)

199n/15

MI-HTSE-S2 Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)

199n/16

MI-FHSE-S2 Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)

199n/17

Bases:B501 standard analogue detector baseB501DG analogue deep baseB524IEFT analogue short circuit isolator baseB501AP intelligent sensor baseB524IEFT-1 short circuit isolator B524HTR heater baseB524RTE latching relay baseHRZ-1000BSD standard base with Schottky diode

Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.MI-PTIR-S2I Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit

isolator (B501AP, B524HTR and B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/01

MI-PTSE-S2I Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/02

HRZ-1002 Conventional photo thermal detector (HRZ-1000BSD base) 199p/04MI-PTIR-S2 Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT-

1, B524HTR and B524RTE bases)199p/06

Note: Certified at the following settings: -

Page 251: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 241

Certificated Products LPCB Ref. No.

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

MI-PTSE-S2 Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)

199p/07

Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

Bases:B501 standard analogue detector baseB501AP intelligent detector baseB501DG analogue sensor deep baseB524IEFT analogue short circuit isolator baseB524IEFT-1 analogue sensor short circuit isolator baseB524HTR heater baseB524RTE latching relay baseHRZ-1000BSD standard base with Schottky diode

Certificate No: 199m to EN 54-7: 2000 + A1: 2002Certificate No: 118h to EN 54-7: 2000Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.MI-LZR Analogue addressable photoelectric laser smoke detector (B501, B501DG and B524IEFT

bases)118h/01

Meets the requirements of EN 54-7 at sensitivity settings of 7 to 9 inclusive.-MI-PSE-S2I Analogue addressable optical smoke sensor with short circuit isolator (B501AP,

B524HTR and B524RTE bases)Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

199ab/01

HRZ-1003 Conventional photoelectric detector (HRZ-1000BSD base) 199m/05MI-PSE-S2 Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR

and B524RTE bases)Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

199m/10

Bases:B501 analogue detector baseB501DG analogue deep baseB524IEFT analogue short circuit isolator baseB501AP intelligent sensor baseB524IEFT-1 short circuit isolator baseB524HTR heater baseB524RTE latching relay baseHRZ-1000BSD standard base with Schottky diode

Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005

Beam DetectorsCertificated Products LPCB Ref.

No.MI-LPB2-S2I Analogue optical beam detector with short circuit isolator feature 199w/01

Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2

Ancillaries:

RTS151-KEY Remote test Station 6500 - LRK/BEAMLRK Long Range Kit6500 - MMK/BEAMMMK Multi-Mounting Kit6500 - SMK/BEAMSMK Surface Mounting Kit

Page 252: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

242 31 Dec 2012

MSA AUERThiemannstraβe 1, 12059 Berlin, GermanyTel: +49 30 6886 2531 • Fax: +49 30 6886 2582E-mail: [email protected] • Website: www.msa-auer.de

Certificate No: 911a-(cl-2) to EN 54-10: 2002 + A1: 2005

Flame DetectorsCertificated Products LPCB Ref.

No.4R Conventional Class 1 single IR flame detector

Notes: 1. The device is available with the following variant options (variants are

identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4R-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/01

4I Conventional Class 1 triple IR (IR3) flame detectorNotes:

1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only.

2. The device is available with the following variant options (variants are identified by 5 letters or numbers following the standard model number outlined respectively below e.g.4I-abcde)

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/02

4M Conventional Class 1 quad IR flame detectorNotes:

1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only.

2. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4M-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4”-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA

911a/03

4L4B Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4L4B-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/04

4L4 Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4L4-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPT

911a/05

Page 253: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 243

Certificated Products LPCB Ref. No.

d. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

4LB Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4LB-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/06

4L Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4L-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/07

4UB Conventional Class 2 UV flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4UB-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/08

4U Conventional Class 2 UV flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.4U-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/09

Multron Systems Pte Ltd217 Kallang Bahru, Multron Building, Singapore 339 347, SingaporeTel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869E-mail: [email protected] • Website: www.multron.com

Certificate No: 548c-(cl-6) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.DET-C103 Conventional Class A1R heat detector (DZ-03 base) 548c/01DET-A103 Intelligent Class A1R heat detector

(DZ-03 base) 548c/02

Bases:DZ-03 Standard detector base

Page 254: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

244 31 Dec 2012

Certificate No: 548d-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Photoelectric Smoke DetectorsCertificated Products LPCB Ref.

No.DET-C102 Conventional Photoelectric Smoke Detector

(DZ-03 base) 548d/01

DET-A102 Intelligent Photoelectric Smoke Detector(DZ-03 base)

548d/02

Bases:DZ-03 Standard detector base

Certificate No: 548k-(cl-6) to EN 54-12: 2002

Beam DetectorsCertificated Products LPCB Ref.

No.DET-105RB Intelligent Optical Beam Detector 548k/01

Notes:1: Meets the requirements of EN 54-12 at the following sensitivity settings:Level 1 1.61 dBLevel 2 2.31dB

Nitin Ventures FZEP.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab EmiratesTel: +97 148865858/859 • Fax: +97 148865800E-mail: [email protected] • Website: www.nitinventures.com

Certificate No: 010h-(cl-1) to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.NV-I-MS Analogue addressable multisensor detector (NV-IA-SB mounting base) 010h/01

Notes:1) Certificated at the following settings:

Mode 1 - High sensitivity smoke detector with standard heat enhancement Mode 2 - Smoke detection only Mode 3 - Medium sensitivity smoke detector with standard heat enhancement Mode 4 - Low sensitivity smoke detector with high heat enhancement Mode 5 - Class A1 heat detector

Also approved in conventional alarm modes 1, 2, 3, 4 and 5.

Bases:NV-IA-SB Mounting Base

Certificate No: 010p-(cl-1) to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.NV-I-H Analogue addressable heat detector (NV-IA-SB mounting base) 010p/03

Notes:1) Meets the requirements of EN54: Part 5 -

Class A1R in mode 1 and in conventional mode Class A2 in mode 2 and in conventional mode Class A2S in mode 3 and in conventional mode Class CR in mode 4 and in conventional mode Class CS in mode 5 and in conventional mode.

NV-C-H-A1R Conventional class A1R heat detector - flashing LED (NV-C-SB mounting base) 010p/05Notes:1) Meets the requirements of EN54: Part 5 - Class A1R

Page 255: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 245

Certificated Products LPCB Ref. No.

NV-C-H-CS Series 65 Conventional Class CS heat detector -Flashing LED (NV-C-SB mounting base) Meets the requirements of EN54: Part 5 - Class CS

010p/14

Bases:NV-IA-SB mounting baseNV-C-SB mounting base

Certificate No: 010q-(cl-1) to EN 54-7: 2000 + A1: 2002

Point Smoke DetectorsCertificated Products LPCB Ref.

No.NV-I-I Analogue addressable ionisation smoke detector (NV-IA-SB mounting base) 010q/02

Notes:1) Meets the requirements of EN54-7: 2000 in modes 1,2,3,4 and 5 in conventional mode

NV-I-O Analogue addressable optical smoke detector (NV-IA-SB mounting base) 010q/03Notes:1) Meets the requirements of EN54-7:2000 in modes 1,2,3 4 and 5 in conventional mode

NV-C-I Conventional ionisation smoke detector - flashing LED (NV-C-SB mounting base) 010q/05NV-C-O Conventional optical smoke detector- flashing LED (NV-C-SB mounting base) 010q/11

Bases:NV-IA-SB mounting baseNV-C-SB mounting base

Nittan Europe LimitedHipley Street, Old Woking, Surrey GU22 9LQ, United KingdomTel: +44 (0)1483 769555/8 • Fax: +44 (0)1483 756686E-mail: [email protected] • Website: www.nittan.co.uk

Certificate No: 041f to EN54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 842a-(cl-1) to EN-54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 755a-(cl-1) to EN54-7: 2000 + A1: 2002

Point Smoke DetectorsCertificated Products LPCB Ref.

No.EV-P Analogue addressable optical smoke detector (UB-4,UB-4-EV,UB-4-SD and STB-4SE-

EV bases) Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.

041f/01

EVC-P EVC-P Conventional optical smoke detector(STB-4-SE-24VR, STB-4SE, UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)

041f/03

EVC-DP Conventional Dual Optical Smoke Detector (STB-4, STB-4SD, STB-4SE, STB-4SE-24VR, UB-4 and UB-5 bases)

755a/01

EVC-P Conventional optical smoke detector (STB-4-SE24VR, STB-4-SE ,STB-4 , UB-4 and UB-4SD bases)

842a/01

ST-P-OM Conventional optical smoke detector (STB-4-SE24VR, STB-4-SE ,STB-4, UB-4 , UB-4R470 and UB-4SDR470 bases)

842a/02

ST-PY-AS Analogue addressable photoelectric smoke detector (STB-4-SE ,STB-4 and UB-4 bases) 842a/03EV-P Analogue addressable photoelectric smoke detector

,STB-4-SE-EV and UB4-EV bases)Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings only.

842a/04

Bases

STB-4 Standard mounting baseSTB-4SE-EV mounting baseSTB-4SE Standard deep mounting baseSTB-4SD Schottky diode mounting baseSTB-4-SE-24VR Relay mounting baseUB-4 Universal mounting base 4 terminalUB-5 Universal mounting base 5 terminalUB-4-EV Universal base

Page 256: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

246 31 Dec 2012

UB-4SD Universal base with Shottky diode

Certificate No: 041h to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.EV-H-A1R Analogue addressable Class A1R heat detector

(UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)041h/01

EV-H-CS Analogue addressable Class CS heat detectorand STB-4SE-EV bases)

041h/02

EVC-H-A2S Conventional Class A2S heat detector(UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)

041h/03

EVC-H-CS Conventional Class CS heat detectorand STB-4SE-EV bases)

041h/04

Bases

UB-4 Universal baseUB-4-EV Universal baseUB-4SD Universal base with Shottky diodeSTB-4SE-EV mounting base

Certificate No: 041g to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1:2002 + A2: 2006 and CEA4021: 1999

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.EV-PH Analogue addressable optical smoke / class A1R heat detector

(UB-4,UB-4-EV,UB-4SD and STB-4SE-EV bases)Note: Meets the requirements of EN 54-7 at Lowest and Highest sensitivity settings.

041g/01

Bases

UB-4 Universal baseUB-4-EV Universal baseUB-4SD Universal base with Shottky diodeSTB-4SE-EV mounting base

Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.notifierfiresystems.co.uk

Certificate No: 199m to EN 54-7: 2000 + A1: 2002Certificate No: 118h to EN 54-7: 2000 + A1: 2002Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.FSL-751E Analogue addressable photoelectric laser smoke detector

(B501, B501DG & B5241EFT bases)118h/01

Note: meets the requirements of EN 54:Part 7 at sensitivity settings of 7 to 9 inclusive.NFXI-OPT Analogue addressable optical smoke sensor with short circuit isolator (B501AP,

B524HTR & B524RTE bases)Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

199ab/01

SD-851E Conventional photoelectric smoke detector (B401 base) 199m/03IDX-751 AE Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP

bases)199m/07

Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings

NFX-OPT Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & 199m/10

Page 257: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 247

Certificated Products LPCB Ref. No.

B524RTE bases)Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

Bases:B501 baseB401 baseB501DG deep baseB5241EFT short circuit isolator baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay baseB501AP Intelligent detector base

Certificate No: 199n to EN 54-5: 2000 + A1: 2002Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.NFXI-TFIX58 Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator

(B501AP, B524HTR & B524RTE bases)199ac/01

NFXI-TFIX78 Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases)

199ac/02

NFXI-TDIFF Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases)

199ac/03

FD-851RE Conventional Class A1R rate of rise heat detector (B401 base) 199n/07FD-851HTE Conventional Class BS heat detector (B401 base) 199n/08NFX-TDIFF Analogue addressable class A1R rate of rise heat sensor (B501AP, B501, B524IEFT-1,

B524HTR & B524RTE bases)199n/15

NFX-TFIX78 Analogue addressable class BS fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)

199n/16

NFX-TFIX58 Analogue addressable class A1S fixed temperature heat sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)

199n/17

Bases:B501 baseB401 baseB401R standard base with resistorB401RSD standard base with resistor and schottky diodeB401SD standard base with schottky diodeB401DG deep baseB501AP intelligent sensor baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.NFXI-SMT3 Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit

isolator (B501AP, B524HTR & B524RTE bases)Note: Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/01

NFXI-SMT2 Analogue addressable photo-thermal multi-criteria smoke sensor with short circuit isolator (B501AP, B524HTR & B524RTE bases)Note: Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/02

SD-851TE Conventional photoelectric/thermal detector (B401 base) 199p/03Note: Meets the requirements of EN54-7: 2000 at "High", 'Medium' and 'Low' sensitivity settings

Page 258: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

248 31 Dec 2012

Certificated Products LPCB Ref. No.

NFX-SMT3 Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)Note: Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199p/06

NFX-SMT2 Analogue addressable photo-thermal multi-criteria sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)Note: Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199p/07

IRX-751CTEM Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501DG and B524IEFT-1 bases)

199t/01

Note: Certified at the following settings: -Normal Mode:Alarm Levels 1 to 5 (Multi-criteria): EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R

Nuisance Environment Applications: Application 0, Alarm Level 4 EN54-7, LPS1279 & CEA 4021 Application 1, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 2, Alarm Level 4 or 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 3, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 4, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021 Application 5, Alarm Level 5 EN54-7 & CEA 4021 Application 6, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021

Bases:B501 baseB401 baseB501DG deep baseB524IEFT-1 analogue short circuit isolator baseB501AP intelligent sensor baseB524HTR heater baseB524RTE latching relay base

Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005

Beam DetectorsCertificated Products LPCB Ref.

No.NFXI-BEAM Analogue optical beam detector with short circuit isolator feature. 199w/01

Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2

NFXI-BEAM-T Analogue optical beam detector with self test facility and short circuit isolator feature. 199w/02Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2

Ancillaries:

RTS151-KEY Remote test Station 6500 - LRK/BEAMLRK Long Range Kit6500 - MMK/BEAMMMK Multi-Mounting Kit6500 - SMK/BEAMSMK Surface Mounting Kit

Page 259: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 249

Notifier Fire Systems IndiaHoneywell Fire Systems, BSEL Tech Park, Floor 6, 603, Sector 30A, opposite Vashi Station, Vashi, New Mumbia, IndiaTel: +91 022 67122427 • Fax: +91 02267122422E-mail: [email protected] • Website: www.myhoneywell.com

Certificate No: 550b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.SDX-751TEM Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1

bases)550b/03

Notes: 1) Meets the requirements of EN 54-7:2000 at sensitivity settings 1 to 52) Meets the requirements of EN 54-5:2000 at Class A1R

NFX-SMT2-yy Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550b/05

NFXI-SMT2-yy Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes:1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550e/02

Bases:B501 Standard baseB501DG Deep analogue detector baseB5242EFT-1 Short circuit islolator baseB501AP intelligent detector baseB524HTR heater baseB524RTE latching relay base

Certificate No: 550c to EN 54-5: 2000 + A1: 2002Certificate No: 550f to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.FDX-551EM Analogue addressable Class A1S fixed temperature heat detector (B501,

B501DG and B5241EFT-1 bases)550c/04

FDX-551REM Analogue addressable Class A1R high temperature rate of rise heat detector (B501, B501DG and B5241EFT-1 bases)

550c/05

NFX-TDIFF-yy Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/06

NFX-TFIX58-yy Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/07

NFXI-TDIFF-yy Analogue addressable class A1R rate of rise heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Note:

550f/01

Page 260: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

250 31 Dec 2012

Certificated Products LPCB Ref. No.

1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates WhiteNFXI-TFIX58-yy Analogue addressable class A1S fixed temperature heat detector with short circuit

isolator (B501AP, B524HTR and B524RTE bases) Note: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550f/02

B501 Standard baseB501DG Deep analogue detector baseB542IEFT-1 Short circuit islolator baseB501AP intelligent detector baseB524HTR heater baseB524RTE latching relay base

Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 550d to EN54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.SDX-751EM Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases) 550a/03

Notes:1) Meets EN 54-7 with low, medium and high sensitivity settings

NFX-OPT-yy Analogue addressable optical smoke detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity

550a/04

NFXI-OPT-yy Analogue addressable optical smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes: 1) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White2) Meets the requirements of EN 54-7: 2000 at high and low sensitivity

550d/01

Bases:B501 standard analogue detector baseB501DG deep analogue detector baseB5241EFT-1 analogue short circuit isolator baseB501AP intelligent detector baseB524HTR heater baseB524RTE latching relay base

Panasonic Corporation1668, Fujikata, Tsu-shi, Mie-ken, JapanTel: +46 40 697 70 00 • Fax: +46 40 697 70 99E-mail: [email protected] • Website: http://pesn.panasonic.se

Certificate No: 1012a-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.Type 2840 Intrinsically safe analogue addressable photoelectric smoke detector

(Type 2843 base)1012a/01

Base: Type 2843 Intrinsically safe backbox

Page 261: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 251

Certificate No: 1012b-(cl-1) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.Type 2841 Intrinsically safe analogue addressable class P heat detector

(Type 2843 base)1012b/01

Note:Meets EN54 Part 5 for classes A1, A2S & BS

Base: Type 2843 Intrinsically safe backbox

Pelco Finland OyKalkkipellontie 6, 02650, Espoo, FinlandTel: +358 10 446 511 • Fax: +358 10 446 5103E-mail: [email protected] • Website: www.pelco.com/nordic

Certificate No: 199u to EN 54-12: 2002Certificate No: 199w to EN 54-12: 2002 and EN 54-17: 2005

Beam DetectorsCertificated Products LPCB Ref.

No.EB-6500R Conventional optical beam detector

Note:1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2

199u/01

EB-6500RS Conventional optical beam detector with self test facility Note:1. Meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2

199u/02

EB-6500A Analogue optical beam detector with short circuit isolator feature 199w/01Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2

EB-6500SA Analogue optical beam detector with self test facility and short circuit isolator feature 199w/02Note: meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1, 2, 3, 4 and Acclimate levels 1 & 2

Ancillaries:

RTS151-KEY Remote test Station 6500 - LRK/BEAMLRK Long Range Kit6500 - MMK/BEAMMMK Multi-Mounting Kit6500 - SMK/BEAMSMK Surface Mounting Kit

Certificate No: 199m to EN 54-7: 2000 + A1: 2002

Smoke DetectorsCertificated Products LPCB Ref.

No.ED2351E Conventional photoelectric detector

(B401, B401DG, B401R, B401SD and B401RSD bases)199m/03

Note:1. Meets EN 54-7: 2000 with Low, Medium and High sensitivites

Bases:B401 standard baseB401DG deep baseB401R standard base with 470 ohm resistorB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB501 Analogue sensor base

Page 262: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

252 31 Dec 2012

B501DG Analogue sensor deep baseB524IEFT Analogue sensor isolator baseB524HTR Heater baseB524RTE Latching relay base

Certificate No: 199n to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.ED5351E Class A1R conventional rate of rise heat detector

(B401, B401DG, B401R and B401RSD bases)199n/07

ED4351E Class BS conventional heat detector(B401, B401DG, B401R, B401SD and B401RSD bases)

199n/08

ED5351TE Class A2S conventional fixed temperature heat detector(B401, B401R, B401RSD, B401SD and B401DG bases)

199n/14

Bases:B401 standard baseB401DG deep baseB401R standard base with 470 ohm resistorB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB501 analogue sensor baseB501AP intelligent detector baseB501DG analogue sensor deep baseB524IEFT analogue sensor isolator baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay base

Certificate No: 199p to EN54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003Certificate No: 010aq-(cl-2) to LPS 1274: 2005 EN 54-5: 2000 + A1: 2002 LPS 1265: 2004

Multi Criteria DetectorsCertificated Products LPCB Ref.

No.EDI-55 Analogue addressable CO/heat multisensor detector

(EBI-10, base)010aq/01

Notes:1. Approved with the following mode configurations:-

Mode 1 30 ppm with high thermal enhancement (most sensitive) Mode 2 33 ppm with CO only Mode 3 40 ppm with low thermal enhancement (nominal sensitivity) Mode 4 45 ppm with high thermal enhancement (least sensitive) Mode 5 heat onlyA1R

2. Mode 1 , 3, and 4 are approved to LPS1274:2005 and EN 54-5:2000 + A1: 20023. Mode 2 is approved to LPS 1265:20044. Mode 5 is approved to EN 54-5:2000 + A1:2002

Conditions of approval include;

The EDI-55 should only be installed in accordance with the manufacturers recommendations.The EDI-55 should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning/flaming fires.Refer to technical publication D01692 for limitations on the use of carbon monoxide fire detection.

ED2351TEM Conventional optical/thermal smoke & heat detector(B401, B401DG, B401R, B401SD and B401RSD bases)

199p/03

Note: 1. Meets the requirements of EN 54-5: 2000 at class A1R and EN 54-7: 2000 at High, Medium and Low.

ESMI2251CTLE Analogue addressable multi-criteria fire detector and incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG and B524IEFT-1 bases)

199t/01

Note: Certified at the following settings: -

Page 263: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 253

Certificated Products LPCB Ref. No.

Normal Mode:Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R

Nuisance Environment Applications:Application 0, Alarm Level 4 EN54-7, LPS1279 & CEA 4021Application 1, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 2, Alarm Level 4 or 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 3, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 4, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 5, Alarm Level 5 EN54-7 & CEA 4021Application 6, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021

Bases:B401 standard baseB401DG deep baseB401R standard base with 470 ohm resistorB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB501 standard analogue detector baseB501AP intelligent detector baseB501DG Deep detector baseB524IEFT Short circuit isolator baseB524HTR Heater baseB524RTE Latching relay baseEBI-10 Standard Intelligent Mounting Base

Philton Fire & Security Limited61 Lower Road, Harrow, Middlesex HA2 0DE, United KingdomTel: +44(0) 20-8864-7534 • Fax: +44(0) 20 8864 8631E-mail: [email protected] • Website: www.philton.com

Certificate No: 404c to EN54-20:2006

Aspirating Smoke DetecorsCertificated Products LPCB Ref.

No.Guardian LaserSTAMP high sensitivity aspirating smoke detector

Notes:1. For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be

supplied with power from a power supply complying with EN 54-4.2. The approval of the detector is conditional upon the following requirements:

- Design, installation and commissioning are performed in accordance with the system design manual and instructions.

3. The device is approved for sensitivity Classes A, B and C for sensitivities up to 0.31%/m. The Class of any pipe/hole configuration and detector sensitivity must be determined using PipeCAD.

404c/01

Page 264: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

254 31 Dec 2012

Pittway Tecnologica Srl.Via Caboto 19/3, 34147 Trieste, ItalyTel: +39 040 94 90111 • Fax: +39 040 38 2137E-mail: [email protected] • Website: www.systemsensoreurope.com

European Sales:System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, SwitzerlandTel: +41 44 943 4424 • Fax: +41 44 943 4399E-mail: [email protected] • Website: www.systemsensoreurope.com

Certificate No: 199m to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 199ab to EN 54-7: 2000 + A1: 2002 & EN 54-17: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.22051EI Analogue addressable optical smoke sensor with short circuit isolator (B501AP,

B524HTR and B524RTE bases)Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

199ab/01

ECO1003 Conventional photoelectric smoke detector (ECO1000DB, ECO1000DBR and ECO1000DBRSD)

199m/01

2351E Conventional photoelectric smoke detector (B401, B40DG, B401R, B401SD and B401RSD bases)

199m/03

Note: Meets the requirements of EN54-7:2000 at low, medium and high sensitivity settings

Vision 2020P Conventional photoelectric detector (2020B, 2020DB, 2020BSD, 2020DBSD bases) 199m/0522051EISE Intrinsically safe analogue addressable photoelectric smoke detector (B501, B501AP,

B524HTR and B524RTE bases)199m/07

Note: Meets EN54-7: 2000 at High, Normal & Low sensitivity settings

22051E Analogue addressable optical smoke sensor (B501AP, B501, B524IEFT-1, B524HTR & B524RTE bases)Note: Meets the requirements of EN 54-7: 2000 at high and low sensitivity

199m/10

Bases:2020B standard base2020DB deep base2020BSD standard base with schottky diode2020DBSD deep base with schottky diodeB401 standard baseB401DG deep baseB401R standard base with 470 ohm resistorB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB501 standard analogue detector baseB501AP intelligent detector baseB501DG analogue sensor deep baseB524IEFT analogue sensor isolator baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay baseECO1000B standard base.ECO1000BSD standard base with schottky diode.ECO1000BR standard base, 470 ohm resistor.ECO1000BRSD standard base, 470 ohm resistor and schottky diode.ECO1000BR680 standard base, 680 ohm resistor.ECO1000BR680SD standard base, 680 ohm resistor and schottky diode.ECO1000BR1000 standard base, 1000 ohm resistor.ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode.ECO1000DB deep baseECO1000DBR deep base with 470 ohm resistorECO1000DBRSD deep base with 470 ohm resistor and schottky diodeECO2000B mounting base.

Page 265: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 255

Certificate No: 199n to EN 54-5: 2000 + A1: 2002Certificate No: 199ac to EN 54-5: 2000 + A1: 2002 & EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.52051EI Analogue addressable class A1S fixed temperature heat sensor with short circuit isolator

(B501AP, B524HTR and B524RTE bases)199ac/01

52051HTEI Analogue addressable class BS fixed temperature heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases)

199ac/02

52051REI Analogue addressable class A1R rate of rise heat sensor with short circuit isolator (B501AP, B524HTR and B524RTE bases)

199ac/03

ECO1005 Class A1R conventional thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases)

199n/01

ECO1005T Class A2S conventional fixed temperature heat detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases)

199n/06

5351E Class A1R conventional rate of rise heat detector (B401, B401DG, B401R, B401SD, & B401RSD bases)

199n/07

4351E Class BS conventional heat detector (B401, B401 DG, B401R, B401SD, & B401RSD bases)

199n/08

ECO1004T Class BS conventional high temperature heat detector (ECO1000DB, ECO1000DBR, ECO1000DBRSD, ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases)

199n/09

Vision 2020F Class A2S conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases)

199n/10

Vision 2020HF Class BS conventional fixed temperature heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases)

199n/11

Vision 2020R Class A1R conventional rate of rise heat detector (2020B, 2020DB, 2020BSD, 2020DBSD bases)

199n/12

5451EIS Intrinsically safe conventional A1R heat detector (B401 base) 199n/135351TE Conventional class A2S fixed temperature heat detector

(B401, B401R, B401RSD, B401SD, B401DG bases)199n/14

52051RE Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)

199n/15

52051HTE Analogue addressable class BS fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)

199n/16

52051E Analogue addressable class A1S fixed temperature heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)

199n/17

Bases:2020B standard base2020DB deep base2020BSD standard base with schottky diode2020DBSD deep base with schottky diodeB401 standard baseB401DG deep baseB401R standard base with 470 ohm resistorB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB401R1000 standard base with 1000 ohm resistorB401DGR deep base with 470 ohm resistorB401DGR1000 deep base with 1000 ohm resistorB401DGSD deep base with schottky diodeB501 standard analogue detector baseB501AP intelligent detector baseB501DG analogue sensor deep baseB524IEFT analogue sensor isolator baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay baseECO1000B standard base.ECO1000BSD standard base with schottky diode.ECO1000BR standard base, 470 ohm resistor.ECO1000BRSD standard base, 470 ohm resistor and schottky diode.ECO1000BR680 standard base, 680 ohm resistor.ECO1000BR680SD standard base, 680 ohm resistor and schottky diode.ECO1000BR1000 standard base, 1000 ohm resistor.ECO1000BR1000SD standard base, 1000 ohm resistor and schottky diode.

Page 266: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

256 31 Dec 2012

ECO2000B mounting base.ECO1000DB deep base.ECO1000DBR deep base with 470 ohm resistorECO1000DBRSD deep base with 470 ohm resistor and schottky diode.

Certificate No: 199p to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 & CEA 4021: 2003Certificate No: 199t to LPS 1279 - 1.0: 2006, EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A1: 2006 & CEA 4021: 2003Certificate No: 199aa to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002, CEA 4021: 2003 & EN 54-17: 2005

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.22051TLEI Analogue addressable photo-thermal-IR multi-criteria smoke sensor with short circuit

isolator (B501AP, B524HTR & B524RTE bases)Note: Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/01

22051TEI Analogue addressable photo-thermal multi-criteria smoke sensorwith short circuit isolator (B501AP, B524HTR & B524RTE bases)Note: Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199aa/02

ECO1002 Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR and ECO1000DBRSD bases)

199p/01

Note :Meets the requirements of EN54:5-2000 at class A1R and EN54:7:2000 at pre-set sensitivity

2351TEM Conventional optical/thermal detector (B401, B401DG, B401R, B401SD, & B401RSD bases)

199p/03

Note: Meets the requirements of EN54-5:2000 at class A1R and EN54-7:2000 at 'High' 'Medium' and 'Low' sensitivity settings.

Vision 2020PT Conventional photo thermal detector (2020B, 2020DB, 2020BSD and 2020DBSD bases) 199p/0422051TLE Analogue addressable photo-thermal-IR multi-criteria sensor (B501AP, B501, B524IEFT-

1, B524HTR and B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003 Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199p/06

22051TE Analogue addressable photo-thermal multi-criteria sensor(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases)Note: Certified at the following settings: -

Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

199p/07

2251CTLE-xx-yy Analogue addressable multi-criteria fire detector incorporating CO, photoelectric, thermal and IR sensors (B501, B501AP, B501DG, B524IEFT-1, B524HTR and B524RTE bases)

199t/01

Notes:1.) xx = (Range 0-99) ~ indicates the communication software protocol

2.) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

3.) Certified at the following settings: -

Normal Mode:Alarm Levels 1 to 5 (Multi-criteria) EN54-5 Class A1R, EN54-7, LPS1279 and CEA 4021Alarm Level 6 (Heat Only Mode): EN54-5 Class A1R

Nuisance Environment Applications:Application 0, Alarm Level 4 EN54-7, LPS1279 & CEA 4021Application 1, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 2, Alarm Level 4 or 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 3, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 4, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 5, Alarm Level 5 EN54-7 & CEA 4021Application 6, Alarm Level 5 EN54-5 Class A1R, EN54-7 & CEA 4021Application 7, Alarm Level 5 EN54-5 Class A1R, LPS1279 and CEA 4021

Page 267: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 257

Bases:2020B standard base2020DB deep base2020BSD standard base with schottky diode2020DBSD deep base with schottky diodeB401 standard baseB401DG deep baseB401R standard base with 470 ohm resistorB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB401R1000 standard base with 1000 ohm resistorB401DGR deep base with 470 ohm resistorB401DGR1000 deep base with 1000 ohm resistorB401DGSD deep base with schottky diodeB501 standard analogue detector baseB501AP intelligent detector baseB501DG analogue sensor deep baseB524IEFT analogue sensor isolator baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay baseECO1000B standard baseECO1000BSD standard base with schottky diodeECO1000BR standard base, 470 ohm resistorECO1000BRSD standard base, 470 ohm resistor and schottky diodeECO1000BR680 standard base, 680 ohm resistorECO1000BR680SD standard base, 680 ohm resistor and schottky diodeECO1000BR1000 standard base, 1000 ohm resistorECO1000BR1000SD standard base, 1000 ohm resistor and schottky diodeECO1000DB deep baseECO1000DBR deep base with 470 ohm resistorECO1000DBRSD deep base with 470 ohm resistor and schottky diodeECO2000B mounting base

Certificate No: 199u to EN 54-12: 2002Certificate No: 199w to EN 54-12: 2002 & EN 54-17: 2005

Beam DetectorsCertificated Products LPCB Ref.

No.6500R Conventional optical beam detector 199u/01

Note: meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2

6500RS Conventional optical beam detector with self test facility 199u/02Note: meets the requirements of EN 54-12: 2002 at sensitivity levels 1,2,3,4 & Acclimate levels 1 & 2

6500-yy Analogue optical beam detector with short circuit isolator feature 199w/01Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and Acclimate levels 1 & 22. yy = (Range 00-99) and indicates the software protocol

6500S-yy Analogue optical beam detector with self test facility and short circuit isolator feature 199w/02Note: 1. Meets the requirements of BS EN 54-12: 2002 at sensitivity levels 1,2,3,4 and Acclimate levels 1 & 22. yy = (Range 00-99) and indicates the software protocol

Ancillaries:

RTS151-KEY Remote test Station 6500 - LRK/BEAMLRK Long Range Kit6500 - MMK/BEAMMMK Multi-Mounting Kit6500 - SMK/BEAMSMK Surface Mounting Kit

Page 268: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

258 31 Dec 2012

Plana FabregaC/Caracas, 08030, Barcelona, SpainTel: 0034 93 243 1111 • Fax: 0034 93 243 0350E-mail: [email protected]; [email protected]

Certificate No: 199m to EN 54-7: 2000 + A1: 2002

Smoke DetectorsCertificated Products LPCB Ref.

No.OPT1 Conventional photoelectric smoke detector

(ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR, ECO1000DBRSD bases)

199m/01

ECO1000B standard baseECO1000BSD standard base with schottky diodeECO1000BR standard base, 470 ohm resistorECO1000BRSD standard base, 470 ohm resistor and schottky diodeECO1000BR680 standard base, 680 ohm resistorECO1000BR680SD standard base, 680 ohm resistor and schottky diodeECO1000BR1000 standard base, 1000 ohm resistorECO1000BR1000SD standard base, 1000 ohm resistor and schottky diodeECO1000DB deep baseECO1000DBR deep base with 470 ohm resistorECO1000DBRSD deep base with 470 ohm resistor and schottky diode

Certificate No: 199n to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.TEVOL Conventional photoelectric smoke detector

(ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000, ECO1000BR1000SD, ECO1000DB, ECO1000DBR, ECO1000DBRSD bases)

199n/01

ECO1000B standard baseECO1000BSD standard base with schottky diodeECO1000BR standard base, 470 ohm resistorECO1000BRSD standard base, 470 ohm resistor and schottky diodeECO1000BR680 standard base, 680 ohm resistorECO1000BR680SD standard base, 680 ohm resistor and schottky diodeECO1000BR1000 standard base, 1000 ohm resistorECO1000BR1000SD standard base, 1000 ohm resistor and schottky diodeECO1000DB deep baseECO1000DBR deep base with 470 ohm resistorECO1000DBRSD deep base with 470 ohm resistor and schottky diode

Protec Fire Detection plcProtec House, Churchill Way, Nelson, Lancashire BB9 6RT, United KingdomTel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273E-mail: [email protected] • Website: www.protec.co.uk

Certificate No: 201f to EN 54-7: 2000Certificate No: 201p to EN 54-7: 2000Certificate No: 201ab to EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 201v to EN 54-7: 2000 + A1: 2002 + A2: 2006

Page 269: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 259

Point Smoke DetectorsCertificated Products LPCB Ref.

No.6000PLUS/OP/S Analogue addressable smoke detector with indoor sounder and short circuit isolator

(6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)201ab/01

Notes:1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting2) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250ms

6000PLUS/OP/SX Analogue addressable smoke detector with indoor sounder and short circuit isolator (export) (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201ab/02

Notes:1) Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting2) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250msiii) Dutch Whoop, 500-1500Hz over 3s

3000/ION Conventional ionisation smoke detector (3000/BASE) 201f/013000/OP Mk II Conventional optical smoke detector (3000/BASE) 201f/046000/OP MK II Analogue addressable optical smoke detector (6000/BASE and 6000/DIB bases) 201p/01

Note: Meets requirements of EN 54-7: 2000 at the following mode settings: i. Normal sensitivity mode

6000PLUS/OP Analogue addressable smoke detector(6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201v/01

Notes: Meets the requirements of EN 54-7: 2000 at the medium sensitivity setting

Bases:6000/BASE standard low profile base6000/DIB isolator base3000/BASE Standard Base6000PLUS/BASE, standard mounting base6000PLUS/FFBASE, recessed mounting baseN28-075-01, Plug and Play Fast Fix baseN28-075-02, Plug and Play Surface base

Certificate No: 201g to EN 54-5: 2000 + A1: 2002Certificate No: 201r to EN 54-5: 2000Certificate No: 201w to EN 54-5: 2000 + A1: 2002Certificate No: 201aa to EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.6000PLUS/HT/S Analogue addressable heat detector with indoor sounder and short circuit isolator

(6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)201aa/01

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A22) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250ms

6000PLUS/HT/SL Analogue addressable heat detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201aa/02

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A22) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250ms

3) The beacon functionality is not included within the scope of this approval

6000PLUS/HT/TSL Analogue addressable heat detector with talking indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201aa/03

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A1 and Class A22) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250msiii) Bell, 800Hz

Page 270: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

260 31 Dec 2012

Certificated Products LPCB Ref. No.

iv) Voice message, F_EVAC2: Female voice “evacuation message” V2, “Attention, attention. This is an emergency. Please leave the building by the nearest available exit”.3) The beacon functionality is not included within the scope of this approval

3000/TEMP56 Conventional class A1 rate of rise and fixed temperature heat detector (3000/BASE) 201g/013000/TEMP64 Conventional class A2 rate of rise fixed temperature (3000/BASE) 201g/026000/TEMP Analogue addressable heat detector (6000/BASE & 6000/DIB bases) 201r/01

Note: Meets requirements of EN 54-5: 2000 at Class A1 (High sensitivity) and A2 (Normal sensitivity).

6000PLUS/HT Analogue addressable heat detector (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201w/01

Note: Meets the requirements of EN 54-5: 2000 at Class A1 and Class A2

Bases:3000/BASE standard base6000/BASE standard low profile base6000/DIB isolator base6000PLUS/BASE, standard mounting base6000PLUS/FFBASE, recessed mounting baseN28-075-01, Plug and Play Fast Fix baseN28-075-02, Plug and Play Surface base

Certificate No: 201j to EN 54: Part 5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 and CEA 4021: 2003Certificate No: 201q to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021Certificate No: 201s to EN 54-5: 2000, EN 54-7: 2000 and CEA 4021Certificate No: 201u to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003Certificate No: 201x to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 201y to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003Certificate No: 201z to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003, EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 201ac to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005, CEA4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.6000PLUS/OPHT/I Analogue addressable multisensor detector with short circuit isolator (6000PLUS/BASE,

6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)201ac/01

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings

3000/OPHT Mk II Conventional optical smoke and Class A2 heat detector (3000/BASE) 201j/016000/OPHT Mk II Analogue addressable optical smoke and Class A2 heat multisensor detector

(6000/BASE & 6000/DIB bases).201q/01

Note:1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode settings only:

i) Normal sensitivity mode ii) Low sensitivity mode

6000/OPHTCO Analogue addressable optical smoke, CO and Class A2 heat multisensor detector (6000/BASE & 6000/DIB bases)

201s/01

Notes:1) Meets requirements of EN 54-7: 2000 and CEA 4021 at the following mode settings only:

i) Normal sensitivity mode II) Low sensitivity mode

2) The CO element is not LPCB approved6000PLUS/OPHT Analogue addressable multisensor detector (6000PLUS/BASE, 6000PLUS/FFBASE,

N28-075-01 and N28-075-02 bases)201u/01

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings

6000PLUS/OPHT/S Analogue addressable multisensor detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201x/01

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:

Page 271: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 261

Certificated Products LPCB Ref. No.

i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms

6000PLUS/OPHT/SX Analogue addressable multisensor detector with indoor sounder and short circuit isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201x/02

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s

6000PLUS/OPHT/SL Analogue addressable multisensor detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201x/03

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:i) Continuous 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250ms 4) The beacon functionality is not included within the scope of this approval

6000PLUS/OPHT/TS Analogue addressable multisensor detector with talking indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201x/04

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice Message, F_EVAC2: Female voice evacuation message V2,

Attention, attention. This is an emergency. Please leave the building by the nearest available exit.

6000PLUS/OPHT/TSX Analogue addressable multisensor detector with talking indoor sounder and short circuitisolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201x/05

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:i) Continuous, 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250msiii) Dutch Whoop, 500-1500Hz over 3siv) Bell, 800Hz

6000PLUS/OPHT/TSL Analogue addressable multisensor detector with talking indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201x/06

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:i) Continuous, 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250msiii) Bell, 800Hziv) Voice message, F_EVAC2: Female voice evacuation message V2, Attention, attention. This is an emergency. Please leave the building by the nearest available exit.4) The beacon functionality is not included within the scope of this approval

6000PLUS/OPHTCO Analogue addressable multisensor and CO detector with short circuit isolator (6000PLUS/BASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201y/01

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) The CO functionality is not included within the scope of this approval

6000PLUS/OPHTCO/S Analogue addressable multisensor and CO detector with indoor sounder and short circuit isolator (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201z/01

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms

4) The CO functionality is not included within the scope of this approval6000PLUS/OPHTCO/SX Analogue addressable multisensor and CO detector with indoor sounder and short circuit 201z/02

Page 272: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

262 31 Dec 2012

Certificated Products LPCB Ref. No.

isolator (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets rhe requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:i) Continuous, 990Hzii) Warble, 990Hz for 250ms and 730Hz for 250msiii) Dutch Whoop, 500-1500Hz over 3s 4) The CO functionality is not included within the scope of this approval

6000PLUS/OPHTCO/SL Analogue addressable multisensor and CO detector with indoor sounder, short circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201z/03

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms

4) The CO and beacon functionality are not included within the scope of this approval6000PLUS/OPHTCO/TSL Analogue addressable multisensor and CO detector with talking indoor sounder short

circuit isolator and beacon (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201z/04

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Bell, 800Hz iv) Voice message, F_EVAC2: Female voice evacuation message V2,

Attention, attention. This is an emergency. Please leave the building by the nearest available exit.4) The CO and beacon functionality are not included within the scope of this approval

6000PLUS/OPHTCO/TSLX Analogue addressable multisensor and CO detector with talking indoor sounder, short circuit isolator and beacon (export) (6000PLUSBASE, 6000PLUS/FFBASE, N28-075-01 and N28-075-02 bases)

201z/05

Notes:1) Meets the requirements of EN 54-5: 2000 at Class A22) Meets the requirements of EN 54-7: 2000 at the medium and low sensitivity settings3) Meets the requirements of EN 54-3: 2001 with the following tones:

i) Continuous, 990Hz ii) Warble, 990Hz for 250ms and 730Hz for 250ms iii) Dutch Whoop, 500-1500Hz over 3s iv) Bell, 800Hz

4) The CO and beacon functionality are not included within the scope of this approval

Bases:3000/BASE standard base6000/BASE standard low profile base6000/DIB isolator base6000PLUS/BASE, standard mounting base6000PLUS/FFBASE, recessed mounting baseN28-075-01, Plug and Play Fast Fix baseN28-075-02, Plug and Play Surface base

Safex Fire Services Limited202 Dhanraj Industrial Estate, Sun Mill Road, Lower Parel West, Mumbai-400 013, IndiaTel: +91-22-24938108 • Fax: +91-22-24950224E-mail: [email protected] • Website: www.safexfire.com

Certificate No: 506a-(cl-2) to EN 54-7 : 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.SF-871 Conventional photoelectric smoke detector (AHMB-L Base) 506a/01

Page 273: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 263

Bases

AHMB-L mounting base

Certificate No: 506b-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 ,EN 54-5: 2000 + A1: 2002 , CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.SF-0315-2 (2 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/01SF-0315-3 (3 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/02SF-0315-4 (4 Wire) Optical smoke and class A2 heat detector (AHMB-031 Base) 506b/03

Bases

AHMB-031 mounting base

Sareme UABNaugarduko str. 32/2, Vilnius LT2006, LithuaniaTel: +3705 2135047 • Fax: +3705 2333567E-mail: [email protected]

Certificate No: 512d to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.EA323-2 Conventional 2 wire 24 VDC class A2S fixed temperature and rate-of-rise heat detector

(P/N854001 base)512d/01

EA323-4 Conventional 4 wire 12VDC class A2S fixed temperature and rate-of-rise heat detector (P/N854001 base)

512d/05

Bases:P/N854001 4-Wire detector base

Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.EA-318-2 Conventional 2 wire photoelectric smoke detector (P/N852001 base) 512a/01EA-318-4-12 Conventional 4 wire photoelectric smoke detector (P/N854001 base) 512a/03

Bases:P/N852001 2-wire detector baseP/N854001 4-wire detector base

Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 +A1: 2002 + A2: 2006 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.EA-318-2H Conventional 2 wire photoelectric smoke and heat detector (P/N852001 base) 512b/01EA-318-2H-LED Conventional 2 wire photoelectric smoke and heat detector with remote LED output

(P/N854001 base)512b/02

Bases:P/N854001 4-wire detector baseP/N852001 2-wire detector base

Page 274: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

264 31 Dec 2012

Schlumberger Oilfield UK PLC, Sensor Highway Limited (Schlumberger, Southampton)Unit 7, The Quadrangle, Abbey Park Industrial Estate, Romsey, Southampton, Hampshire SO51 9DL, United KingdomTel: +44 (0)1794 529600 • Fax: +44 (0)1794 514931E-mail: [email protected] • Website: www.slb.com

Certificate No: 648c to LPCB Test Schedule E120656/1.0

Linear Heat Detection SystemCertificated Products LPCB Ref.

No.Sensa DTS240SC Distributed Temperature Sensor

SC: Single Channel648c/01

Notes: 1. Approval is conditional on the following:

- The use of SensorLine II or SensorTube II optical fibres (Stainless Steel).

- The optical fibre lengths should not exceed 4km.

- The system should be installed and configured in accordance with the manufacturers instructions.

- The zone/alarm configuration parameters should be set in accordance with the manufacturers instructions for an alarm response equivalent to Class A1R as specified in EN 54-5: 2000 + A1: 2002.

2. The product is known as the LTS240SC when supplied in a wall-mount or rack-mount housing.

Sensa DTS240TC Distributed Temperature SensorTC: Twin Channel

648c/01

Notes: 1. Approval is conditional on the following:

- The use of SensorLine II or SensorTube II optical fibres (Stainless Steel).- The optical fibre lengths should not exceed 4km.- The system should be installed and configured in accordance with the manufacturers instructions.- The zone/alarm configuration parameters should be set in accordance with the manufacturers instructions for an alarm response equivalent to Class A1R as specified in EN 54-5: 2000 + A1: 2002.

2. The product is known as the LTS240TC when supplied in a wall-mount or rack-mount housing.

AnnexSensor Highway Ltd. is part of Schlumberger Oilfield UK PLC and known as Schlumberger, Southampton

SHIELD FIRE, SAFETY AND SECURITY LTD29th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United KingdomTel: +44 207 712 1610 • Fax: +44 207 712 1578E-mail: [email protected] • Website: www.shieldglobal.com

Certificate No: 548k to EN 54-12: 2002

Beam DetectorsCertificated Products LPCB Ref.

No.D-A430/R Intelligent optical beam detector 548k/01

Page 275: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 265

Certificated Products LPCB Ref. No.

Notes: 1) Meets the requirements of EN 54-12 at the following sensitivity settings:

Level 1 - 1.61 dB Level 2 - 2.31dB

Certificate No: 548d-(cl-4) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Smoke DetectorsCertificated Products LPCB Ref.

No.D-C401 Conventional photoelectric smoke detector (DZ-03 base) 548d/01D-A411 Intelligent photoelectric smoke detector (DZ-03 base) 548d/02

Bases:DZ-03 Standard detector base

Certificate No: 548c-(cl-4) to EN 54-5: 2000 + A1: 2002

Heat DetectorsCertificated Products LPCB Ref.

No.D-C402 Conventional Class A1R heat detector (DZ-03 base) 548c/01D-A412 Intelligent Class A1R heat detector (DZ-03 base) 548c/02

Bases:DZ-03 Standard detector base

Siemens Switzerland Limited, Building Technologies DivisionInternational Headquarters, Gubelstrasse 22, CH-6301 Zug, SwitzerlandTel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22

Manufacturing at:Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, SwitzerlandTel: +41 1 922 6111 • Fax: +41 1 922 6450

UK Sales:Siemens Building Technologies Limited, FSP DivisionTel: +44 (0)1784 461616 • Fax: +44 (0)1784 464646

Certificate No: 126x-(cl-1) to EN 54:7: 2000 + A1:2002 + A2:2006Certificate No: 126ab-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 126am-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005Certificate No: 531c-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 531d-(cl-1) to EN 54-7:2000 + A1:2002 + A2: 2006, EN 54-17: 2005 and CEA4021: 2003-07Certificate No: 531e-(cl-1) to EN 54-7: 2000 + A1: 2002 + A1: 2006 and EN 54-17: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.FDO241 Analogue addressable photoelectric smoke detector with short circuit isolator

(FDB221, FDB201, FDB291 and FDB292 bases)126ab/01

FDO221 Analogue addressable photoelectric smoke detector with short circuit isolator(FDB221, FDB201, FDB291 and FDB292 bases)

126ab/02

DO1131A Addressable photoelectric smoke detector with short circuit isolator (DB1131A base) 126am/03Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings

DO1152A Addressable photoelectric smoke detector with short circuit isolator(DB1151A base)

126am/05

Page 276: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

266 31 Dec 2012

Certificated Products LPCB Ref. No.

Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings

DOT1131A Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1131A base)

126am/06

Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings

DOT1152A Addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (DB1151A base)

126am/09

Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings

R970 Scattered light smoke detector (Z94 base) 126x/01Note: 1. Meets requirements of EN54-7 at standard (2.5%/m) and increased (1.7%/m) sensitivity setting

DO1101A Conventional photoelectric smoke detector(DB1101A base)

126x/02

DO1101A-Ex Intrinsically safe conventional photoelectric smoke detector(DB1101A base)

126x/03

DO1151A Addressable photoelectric smoke detector(DB1151A base)

126x/04

Note: 1. Meets EN54-7 at Personen/life sensitivity settings

DOT1151A Addressable photoelectric smoke detector with thermal enhancement(DB1151A base)

126x/05

Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings

DOT1151A-Ex Intrinsically safe addressable photoelectric smoke detector with thermal enhancement (DB1151A base)

126x/06

Note: 1. Meets EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings

OH320C Conventional photoelectric smoke detector with thermal enhancement (SO320 base) 531c/02OP320C Conventional photoelectric smoke detector (SO320 base) 531c/04OH620 Analogue addressable photoelectric smoke detector with thermal enhancement

(SO620 base)531c/05

Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settingsOP620 Analogue addressable photoelectric smoke detector (SO620 base) 531c/06

Note: Meets the requirements of EN54-7: 2000 at Standard and High sensitivity settingsOP820 Analogue addressable photoelectric smoke detector (SO820 base) 531c/07

Note: Meets the requirements of EN54-7: 2000 at Personen/life and Immobilien/property sensitivity settings

OH720 Analogue addressable multi sensor smoke detector(DB720, DB721 bases)

531d/01

Note: 1. Meets the requirements of EN 54-7 in the following sensitivities: 1 - Robust 3.5%/m 2 - Sensitive 2.5%/m

OP720 Analogue addressable smoke detector with short circuit isolator (DB720, DB721 bases) 531e/01Note:1. Meets the requirements of EN 54-7 in the following sensitivities: 1 - Standard 2.5%/m 2 - Sensitive 1.8%/m

OH320A Analogue addressable photoelectric smoke detector with thermal enhancement and short circuit isolator (SO320 base)

531e/02

Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings

OP320A Analogue addressable photoelectric smoke detector with short circuit isolator (SO320 base)

531e/03

Note: 1. Meets EN54-7: 2000 at Standard and High sensitivity settings

Bases:Z94 baseFDB221 baseFDB201 base "Collective"FDB291 base attachment surfaceFDB292 base attachment surface wetDB720 Detector baseDB721 Detector base with loop contactDB1101A baseDB1131A baseDB1151A base

Page 277: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 267

DBZ1191 base attachmentSO620 Analogue addressable (AnalogPLUS) detector baseSO820 Analogue addressable (Interactive) detector baseSO320 base for SynovaTM 300 series detectors

Certificate No: 126aa-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005Certificate No: 126an-(cl-1) to EN 54-5: 2000 + A1: 2002Certificate No: 531b-(cl-1) to EN 54-5: 2000 + A1: 2002Certificate No: 531f-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005Certificate No: 126av-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005

Point Heat DetectorsCertificated Products LPCB Ref.

No.FDT241 Analogue addressable rate of rise heat detector with short circuit isolator.

(FDB221, FDB201, FDB291 and FDB292 bases)126aa/01

Note: Meets EN 54-5: 2000 at Class A1R, A1S, BR and BS.FDT221 Analogue addressable rate of rise heat detector with short circuit isolator (FDB221,

FDB201, FDB291 and FDB292 bases)126aa/02

Note: Meets EN 54-5: 2000 at Class A1R and BRDT1101A Conventional class A1R heat detector (DB1101A base) 126an/01DT1101A-Ex Conventional intrinsically safe class A1R heat detector (DB1101A base) 126an/02DT1102A Conventional class B heat detector (DB1101A base) 126an/03DT1102A-Ex Conventional intrinsically safe class B heat detector (DB1101A base) 126an/04DT1151A-Ex Analogue addressable intrinsically safe heat detector (DB1151A base) 126an/06

Note: Meets EN54-5: 2000 at class A1R and class BDT1131A Analogue addressable class A1R heat detector with short circuit isolator

(DB1131A base)126av/01

DT1152A Analogue addressable heat detector with short circuit isolator (DB1151A base)

126av/02

Note:

1. Meets EN 54-5:2000 at class A1R and class BS HI320C Conventional class A1R heat detector (SO320 base) 531b/03HI322C Conventional class A2 heat detector (SO320 base) 531b/04HI620 Analogue addressable (AnalogPLUS) Class A1R heat detector (SO620 base) 531b/05HI820 Analogue addressable (Interactive) heat detector (SO820 base) 531b/06

Note: Meets the requirements of EN54-5: 2000 at class A1R and class BRHI720 Analogue addressable class A2S and A2R heat detector with short circuit isolator

(DB720, DB721 bases)

531f/01

Notes:1. Meets the requirements of EN 54-5 at classes A2S and A2R

HI722 Analogue addressable class A2S heat detector with short circuit isolator (DB720, DB721 bases)

531f/02

Notes:1. Meets the requirements of EN 54-5 at class A2S

HI320A Analogue addressable class A1R heat detector with short circuit isolator (SO320 base) 531f/03HI322A Analogue addressable class A2 heat detector with short circuit isolator (SO320 base) 531f/04

Bases:Z94 baseDFB1190 baseFDB221 baseFDB201 base “Collective”FDB291 base attachment surfaceFDB292 base attachment surface wetDB720 Detector baseDB721 Detector base with loop contactDB1101A base for conventional addressing DB1131A base for analogue addressingDB1151A base for interactive fire detectorsSO320 base for SynovaTM 300 series detectorsSO620 Analogue addressable (AnalogPLUS) detector baseSO820 Analogue addressable (Interactive) detector base

Page 278: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

268 31 Dec 2012

Certificate No: 126ag-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005Certificate No: 126ak-(cl-1) to EN 54-12: 2002 and EN 54-17: 2005

Beam DetectorsCertificated Products LPCB Ref.

No.FDL241-9 Analogue addressable beam detector with short circuit isolator (FDLB291 base) 126ag/01

Note: Certified at sensitivity settings 30%, 50% and 65%DLO1191 Optical beam smoke detector with short circuit isolator (DLB1191A base) 126ak/01

Note: 1. Certified at sensitivity setting 30%, 50% and 65%

Bases:FDLB291 baseDLB1191A base

Certificate No: 126s-(cl-1) to EN 54-10: 2002Certificate No: 126af-(cl-1) to EN 54-10: 2001 + A1: 2005 and EN 54-17: 2005Certificate No: 126ay-(cl-1) to EN 54-10: 2002 and EN 54-17: 2005

Flame DetectorsCertificated Products LPCB Ref.

No.FDF241-9 Analogue addressable infra red flame detector with short circuit isolator (FDFB291 base) 126af/01

Note:1. Meets EN 54-10: 2002 at Class 1 and 2 only

FDF221-9 Analogue addressable infra red flame detector with short circuit isolator (FDFB291 base) 126af/02Note: 1. Meets EN 54-10: 2002 at Class 1 and 2 only

DF1192 Analogue addressable infra red flame detector with short circuit isolator (DFB1190 Base)

126ay/01

Note: 1. Certificated in increased & standard sensitivity settings - Class 1 and 2 respectively.

DF1191 Analogue addressable infra red flame detector with short circuit isolator (DFB1190 Base)

126ay/02

Note: 1. Certificated in increased & standard sensitivity settings - Class 1 and 2 respectively.

DF1151-Ex Analogue addressable IS infra red flame detector with short circuit isolator (DFB1190 Base)

126ay/03

Note: 1. Certificated in increased & standard sensitivity settings - Class 1 and 2 respectively.

DF1101-Ex Conventional I.S. infra red flame detector (DFB 1190 base) 126s/03Note: 1. Certificated in "increased" & "standard" sensitivity settings - Class 1 and 2 respectively.

Bases:Z94 baseDFB 1190 baseFDFB291 base

Certificate No: 126ah-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, CEA4021: 2003 and EN 54-17: 2005

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.FDOOT241-9 Analogue addressable multisensor detector with short circuit isolator (FDB201, FDB202,

FDB221, FDB222, FDB291 and FDB293 bases)126ah/01

Note: Meets the requirements of EN 54-5: 2000 at Class A2R & A2S and EN 54-7: 2000 at sensitivity settings:Parameter No. 1 UniversalParameter No. 2 Robust with thermal enhancement Parameter No. 3 Sensitive Parameter No. 4 Balanced with thermal enhancementParameter No. 5 Suppression with thermal enhancementParameter No. 6 Response with thermal enhancementParameter No. 7 Robust / BGD with thermal enhancement

Page 279: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 269

Certificated Products LPCB Ref. No.

FDOOTC241 Analogue addressable multisensor detector with short circuit isolator (FDB221, FDB222, FDSB291 & FDSB293 bases)

Note - the following modes are approved Mode 0 - Neural Fire Detector: 0.0) High Compensation 0.2) Robust 0.4) Balanced 0.5) Suppression 0.6) Fast Response 0.7) High Compensation 0.9) High Sensitive Fast 0.10) Balanced CO 0.12) Suppression CO

Mode 1 - Heat Detector1.1) A1R 1.2) BR 1.3) A1S 1.4) BS

Mode 2 - Smoke Detector 2.0) Universal 2.1) Universal 2.2) Robust 2.3) Sensitive

126ah/03

Bases: FDB221 base with stand offsFDB201 base “Collective” with stand offsFDB202 base “Collective” without stand offsFDB222 base without stand offsFDB291 base attachment surfaceFDB292 base attachment surface wetFDB293 base attachment surface wet

Certificate No: 126az-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & EN 54-17: 2005 and CEA 4021: 2003

Multi-Sensor DetectorsCertificated Products LPCB Ref.

No.FDOOT221 Analogue addressable multisensor detector with short circuit isolator

(FDB221, FDB222, FDB291 and FDB293 bases)126az/01

Note: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings:

Parameter No. 2 Robust with thermal enhancement Parameter No. 4 balanced with thermal enhancement

Bases

FDB221 base with stand offsFDB222 base without stand offsFDB291 base attachment surfaceFDB293 base attachment surface wet

Page 280: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

270 31 Dec 2012

SMS (Novar Systems Ltd)Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016Website: www.smsfire.co.uk

Certificate No: 042ak to EN 54-5: 2000 + A1: 20002, EN 54-3: 2001 + A1: 2002, CEA GEI 1-084: Draft 08.08.00, CEA GEI 1-052: 11.06.97 Draft 2.0,

Point Heat DetectorsCertificated Products LPCB Ref.

No.SEN-780 S-Quad analogue addressable Class P heat detector with sounder

(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)042ak/01

Notes:1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Contiuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs

SEN-780-ST S-Quad analogue addressable Class P heat detector with sounder and strobe(S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042ak/03

Notes:1. Meets the requirement of EN 54: Part 5 at the following settings: State 0 - Class A1 State 5 - Class B2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Contiuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs3. Strobe note included in scope of approval

Bases:S4-700 standard baseS4-FLUSH semi-flush fixing kit

Certificate No: 042an to EN 54-7: 2000 + A1: 2002, EN 54-5: 2000 + A1: 2002, EN 54-3: 2001 + A1: 2002, CEA 4021: 2003-07, CEA 1-084: Draft 08.08.00, CEA GEI 1-052: 11.06.97 Draft 2.0Certificate No: 042bf to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005

Multi Criteria DetectorsCertificated Products LPCB Ref.

No.SEN-770-ST S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector

with sounder and strobe (S4-700 Standard base with or without S4-FLUSH semi-flush mounting kit)

042an/06

Notes: 1. Meets the requirement of EN 54- 5 and EN 54-7 at the following settings: State 0 - Medium optical / Class A1 heat 2. Meets the requirements of EN 54: Part 3 at the following sounder tone settings: High - Continuous 933 Hz Alternate - High 933 Hz for 0.25 secs / Low 700 Hz for 0.25 secs 3. Strobe not included in scope of approval.

SEN-710 S-Quad analogue addressable optical smoke and Class A1 heat multisensor detector(S4-700 base with or without S4-FLUSH mounting kit)Note: 1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:State 0 - Medium optical / Class A1 heat

042bf/01

Bases:S4-700 standard baseS4-FLUSH Semi-flush fixing kit

Page 281: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 271

Certificate No: 042be to EN54-5: 2000 + A1: 2002, EN54-17: 2005, EN54-18: 2005Certificate No: 042bd to EN54-7: 2000 + A1: 2002 + A2: 2006, EN54-17: 2005, EN54-18: 2005

Point Smoke DetectorsCertificated Products LPCB Ref.

No.SEN-715 S-Quad analogue addressable optical smoke detector

(S4-700 base with or without S4-FLUSH mounting kit) Note: 1. Meets the requirements of EN 54: Part 7 at the following settings: State 0 - Medium optical

042bd/01

SEN-720 S-Quad analogue addressableClass P heat detector(S4-700 base with or without S4-FLUSH mounting kit)Note: 1. Meets the requirement of EN 54: Part 5 and requirements of EN 54: Part 7 at the following settings:State 0 - Class A1 heat

042be/01

Bases:S4-700 standard baseS4-FLUSH semi-flush fixing kit

Spectrex IncPeckman Industrial Park, 218 Little Falls Road, Cedar Grove, NJ 07009, USATel: +973 239 8389 • Fax: +973 239 7614E-mail: [email protected] • Website: www.spectrex-inc.com

Certificate No: 911a-(cl-1) to EN 54-10: 2002 + A1: 2005

Flame DetectorsCertificated Products LPCB Ref.

No.Sharpeye 40/40R Conventional Class 1 single IR flame detector

Notes: 1. The device is available with the following variant options (variants are

identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40R-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/01

Sharpeye 40/40I Conventional Class 1 triple IR (IR3) flame detectorNotes:

1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only.

2. The device is available with the following variant options (variants are identified by 5 letters or numbers following the standard model number outlined respectively below e.g.40/40I-abcde)

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/02

Sharpeye 40/40M Conventional Class 1 quad IR flame detectorNotes:

1. Meets the requirements of EN 54-10: 2002 Class 1 at sensitivity setting 2 (default) only.

2. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40M-abcde):

911a/03

Page 282: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

272 31 Dec 2012

Certificated Products LPCB Ref. No.

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 C c. Cable entry - 1=M25 ; 2=3/4”-14NPT d. Housing - S=Stainless steel ; A=Aluminium e. Approval - C= ATEX, IECEx; F= FM, CSA

Sharpeye 40/40L4B Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L4B-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/04

Sharpeye 40/40L4 Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L4-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/05

Sharpeye 40/40LB Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40LB-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/06

Sharpeye 40/40L Conventional Class 2 UV/IR flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40L-abcde):

a. Wiring options - 1 to 5b. Maximum operating temperature - 1=75C ; 2=85Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/07

Sharpeye 40/40UB Conventional Class 2 UV flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40UB-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/08

40/40U Conventional Class 2 UV flame detectorNotes:

1. The device is available with the following variant options (variants are identified by 5 letters/numbers following the standard model number outlined respectively below e.g.40/40U-abcde):

a. Wiring options - 1 to 5 b. Maximum operating temperature - 1=75 C ; 2=85 Cc. Cable entry - 1=M25 ; 2=3/4”-14NPTd. Housing - S=Stainless steel ; A=Aluminiume. Approval - C= ATEX, IECEx; F= FM, CSA

911a/09

Page 283: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 273

Certificated Products LPCB Ref. No.

Sterling Safety SystemsUnit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United KingdomTel: +44(0)1926485282 • Fax: +44(0)1926485090E-mail: [email protected] • Website: www.sterlingsafety.co.uk

Certificate No: 928a to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005Certificate No: 928d to EN 54-5: 2000 + A1: 2002Certificate No: 928j-(cl-6) to EN 54-5: 2000 + A1: 2002 and EN 54-25: 2008

Point Heat DetectorsCertificated Products LPCB Ref.

No.HFI-TA-01 Analogue addressable Class P heat detector with short circuit isolator

(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases)

928a/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

HFI-TAE-01 Analogue addressable Class P heat detector lite (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases)

928d/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

HFW-TA-01 Wireless heat detector (WAB100 base) 928j/01Notes:1. Meets the requirements of EN 54-5 for Class A1R2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

BasesHFI-UB-01 Universal adaptor baseHFI-DUB-01 Deep adaptor baseHFI-DMB-01 Vega adaptor baseHFI-DDB-01 Vega deep adaptor baseHFI-UBS-01 Universal adaptor base with shorting clipHFI-DUBS-01 Deep adaptor base with shorting clipHFI-DMBS-01 Vega adaptor base with shorting clipHFI-DDBS-01 Vega deep adaptor base with shorting clipWAB100 Wireless Adaptor Base

Certificate No: 928b to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.HFI-PA-01 Analogue addressable photoelectric smoke detector with short circuit isolator

(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases)

928b/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

HFI-PAE-01 Analogue addressable photoelectric smoke detector lite (HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases)

928e/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High

Page 284: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

274 31 Dec 2012

Certificated Products LPCB Ref. No.

Optical only level 2 Optical only level 3 Optical only level 4 - Low

BasesHFI-UB-01 Universal adaptor baseHFI-DUB-01 Deep adaptor baseHFI-DMB-01 Vega adaptor baseHFI-DDB-01 Vega deep adaptor baseHFI-UBS-01 Universal adaptor base with shorting clipHFI-DUBS-01 Deep adaptor base with shorting clipHFI-DMBS-01 Vega adaptor base with shorting clipHFI-DDBS-01 Vega deep adaptor base with shorting clip

Certificate No: 928c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003Certificate No: 928f to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Multi-Sensor DetectorsCertificated Products LPCB Ref.

No.HFI-MA-01 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with

short circuit isolator(HFI-UB-01, HFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases)

928c/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:

Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

HFI-MAE-01 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector liteHFI-DUB-01, HFI-DMB-01, HFI-DDB-01, HFI-UBS-01, HFI-DUBS-01, HFI-DMBS-01 and HFI-DDBS-01 bases)

928f/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the following settings:

Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

BasesHFI-UB-01 Universal adaptor baseHFI-DUB-01 Deep adaptor baseHFI-DMB-01 Vega adaptor baseHFI-DDB-01 Vega deep adaptor baseHFI-UBS-01 Universal adaptor base with shorting clipHFI-DUBS-01 Deep adaptor base with shorting clip

Page 285: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 275

HFI-DMBS-01 Vega adaptor base with shorting clipHFI-DDBS-01 Vega deep adaptor base with shorting clip

Certificate No: 928k-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Smoke DetectorsCertificated Products LPCB Ref.

No.HFW-PA-01 Wireless optical smoke detector (WAB100 base) 928k/01

Notes:1. Meets the requirements of EN 54-7 in the normal sensitivity setting2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

Certificate No: 928m-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-25: 2008 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.HFW-MA-01 Wireless multi-criteria detector (WAB100 base) 928m/01

Notes:1. Meets the requirements of EN 54-5 for Class A12. Meets the requirements of EN 54-7 in the normal sensitivity setting3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main battery CR2032A (3 Vdc) - secondary battery

Bases:WAB100 Wireless Adaptor Base

System Sensor3825 Ohio Avenue, Saint Charles, Illinois 60174, USATel: +1 630 377 6580 • Fax: +1 630 377 7245Website: www.systemsensor.com

European Sales Enquiries:System Sensor EuropeTel: +44 (0)1403 891920 • Fax: +44 (0)1403 891921

Certificate No: 118h to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.7251 Analogue addressable photoelectric laser smoke detector (B501, B501AP, B501DG,

B524IEFT, B524IEFT-1 bases)118h/01

Note: meets requirements of EN 54: Part 7 at sensitivities 7 to 9 inclusive

Bases:B501 analogue sensor baseB501AP intelligent detector baseB501DG deep baseB524IEFT short circuit isolator baseB524IEFT-1 short circuit isolator base

Page 286: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

276 31 Dec 2012

System Sensor EuropeKAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United KingdomTel: +44 (0)1527 406700 • Fax: +44 (0)1527 406699Website: www.systemsensoreurope.com

Certificate No: 118h to EN54-7: 2000

Certificated Products LPCB Ref. No.

LZR-1M Analogue addressable photoelectric laser smoke detector (B501, B501DG, B524IEFT, B524IEFT-1 bases)

118h/01

Note: meets requirements of EN 54: 7 at sensitivities 7 to 9 inclusive

BasesB501DG deep baseB524IEFT short circuit isolator baseB524IEFT-1 short circuit isolator base

System Sensor, Honeywell International (I) PVT. LimitedSector 36, Pace City - II, Gurgaon - 122 004, Haryana, IndiaTel: +91 124 4752700 • Fax: +91 124 4752750E-mail: [email protected]

Certificate No: 550a to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 550d to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Smoke DetectorsCertificated Products LPCB Ref.

No.2351E Conventional photoelectric smoke detector

(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases)

550a/01

Note: Meets the requirements of EN54-7:2000 at low, medium & high sensitivity settings.EC01003 Conventional photoelectric smoke detector (ECO1000B, ECO1000BSD, ECO1000BR,

ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases)

550a/02

FL/1003 Conventional photoelectric smoke detector (FL/1000B base)

550a/02

2251EM Analogue addressable optical smoke detector (B501, B501DG and B5241EFT-1 bases) 550a/03Notes : Meets EN 54-7 with low, medium and high sensitivity settings

22051E-xx-yy Analogue addressable optical smoke detector(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes:1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White3) meets the requirements of EN 54-7: 2000 at high and low sensitivity

550a/04

2FA51 Conventional photoelectric smoke detector (BFA1 base) 550a/0522051EI-xx-yy Analogue addressable optical smoke detector with short circuit isolator (B501AP,

B524HTR and B524RTE bases)Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White3) Meets the requirements of EN 54-7: 2000 at high and low sensitivity

550d/01

Page 287: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 277

Bases:B401 standard baseB401DG deep baseB401R standard base with schottky diodeB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB401R1000 standard base with 1000 ohm resistorB401DGR deep base with 470 ohm resistorB401DGR1000 deep base with 1000 ohm resistorB401DGSD deep base with schottky diodeECO1000B standard baseECO1000BSD standard base with schottky diodeECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diodeECO1000BR680 standard base, 680 ohm resistorECO1000BR680SD standard base, 680 ohm resistor and schottky diodeECO1000BR1000 standard base, 1000 ohm resistorECO1000BR1000SD standard base, 1000 ohm resistor and schottky diodeB501 standard analogue detector baseB501DG deep analogue detector baseFL/B401 standard baseFL/1000B standard baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay baseBFA1 standard base

Certificate No: 550b to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003Certificate No: 550e to EN54-5: 2000 + A1: 2002, EN54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 & CEA 4021: 2003

Multi Criteria DetectorsCertificated Products LPCB Ref.

No.2351TEM Conventional optical/thermal detector

(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases)

550b/01

Note: Meets the requirements of EN54-5:2000 at Class A1R and EN54-7:2000 at low, medium & high sensitivity settings.

ECO1002 Conventional photo-thermal detector (ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases)

550b/02

Note: Meets the requirements of EN 54-5:2000 at class A1R at pre-set sensitivity.FL/1002 Conventional optical/thermal detector

base)550b/02

Notes: Meets the requirements of EN54-5 at class A1R at pre-set sensitivity

2251TEM Analogue optical/thermal smoke & heat detector (B501, B501DG and B5241EFT-1 bases)

550b/03

Notes : 1) Meets the requirements of EN 54-7: 2000 at sensitivity settings 1 to 52) Meets the requirements of EN 54-5: 2000 at Class A1R

22051TLE-xx-yy Analogue addressable photo-thermal-IR multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes:1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White3) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550b/04

22051TE-xx-yy Analogue addressable photo-thermal multi-criteria detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White3)Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550b/05

Page 288: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

278 31 Dec 2012

Certificated Products LPCB Ref. No.

2FA51T Conventional photo-thermal class A1R detector (BFA1 base) 550b/06Note: Meets the requirements of EN54-5: 2000 class A1R at pre-set sensitivity

22051TLEI-xx-yy Analogue addressable photo-thermal-IR multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes:1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White3) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550e/01

22051TEI-xx-yy Analogue addressable photo-thermal multi-criteria smoke detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes:1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White3) Certified at the following settings: -Alarm levels 1 to 5 (Multi-criteria): EN 54-5: 2000 class A1R, EN 54-7: 2000 & CEA 4021: 2003Alarm level 6 (Heat only mode): EN 54-5: 2000 class A1R

550e/02

Bases:B401 standard baseB401DG deep baseB401R standard base with schottky diodeB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB401R1000 standard base with 1000 ohm resistorB401DGR deep base with 470 ohm resistorB401DGR1000 deep base with 1000 ohm resistorB401DGSD deep base with schottky diodeECO1000B standard baseECO1000BSD standard base with schottky diodeECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diodeECO1000BR680 standard base, 680 ohm resistorECO1000BR680SD standard base, 680 ohm resistor and schottky diodeECO1000BR1000 standard base, 1000 ohm resistorECO1000BR1000SD standard base, 1000 ohm resistor and schottky diodeB501 standard analogue detector baseB501DG deep analogue detector baseB5241EFT-1 analogue short circuit isolator baseFL/B401 standard baseFL/1000B standard baseB501AP intelligent detector baseB524HTR heater baseB524RTE latching relay baseBFA1 standard base

Certificate No: 550c to EN 54-5: 2000 + A1: 2002Certificate No: 550f to EN54-5: 2000 + A1: 2002 and EN 54-17: 2005

Heat DetectorsCertificated Products LPCB Ref.

No.5351E Class A1R conventional rate of rise heat detector

(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases)

550c/01

Note: Meets the requirements of EN54-5:2000 at class A1R.4351E Class BS conventional heat detector

(B401, B401DG, B401R, B401SD, B401RSD, B401R1000, B401DGR, B401DGR1000 & B401DGSD bases)

550c/02

Note: Meets the requirements of EN54-5:2000 at class BS.ECO1005 Conventional A1R rate-of-rise heat detector

(ECO1000B, ECO1000BSD, ECO1000BR, ECO1000BRSD, ECO1000BR680, ECO1000BR680SD, ECO1000BR1000 & ECO1000BR1000SD bases)

550c/03

FL/1005 Conventional Class A1R rate of rise heat detector (FL/1000B base)

550c/03

Page 289: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 279

Certificated Products LPCB Ref. No.

5251EM Analogue addressable Class A1S fixed temperature heat detector (B501, B501DG and B5241EFT-1 bases)

550c/04

5251REM Analogue addressable Class A1R high temperature rate of rise heat detector (B501, B501DG and B5241EFT-1 bases)

550c/05

52051RE-xx-yy Analogue addressable class A1R rate of rise heat detector (B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/06

52051E-xx-yy Analogue addressable class A1S fixed temperature heat detector(B501AP, B501, B524IEFT-1, B524HTR and B524RTE bases) Notes: 1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550c/07

5FA51R Conventional A1R rate of rise heat detector (BFA1 base) 550c/0852051REI-xx-yy Analogue addressable class A1R rate of rise heat detector with short circuit isolator

(B501AP, B524HTR and B524RTE bases) Notes:1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550f/01

52051EI-xx-yy Analogue addressable class A1S fixed temperature heat detector with short circuit isolator (B501AP, B524HTR and B524RTE bases) Notes:1) xx = (Range 0-99) ~ indicates the communication software protocol2) yy = Colour option ~ IV = Ivory, BK = Black, no reference indicates White

550f/02

Bases:B401 standard baseB401DG deep baseB401R standard base with schottky diodeB401SD standard base with schottky diodeB401RSD standard base with 470 ohm resistor and schottky diodeB401R1000 standard base with 1000 ohm resistorB401DGR deep base with 470 ohm resistorB401DGR1000 deep base with 1000 ohm resistorB401DGSD deep base with schottky diodeECO1000B standard baseECO1000BSD standard base with schottky diodeECO1000BR standard base, 470 ohm resistor ECO1000BRSD standard base, 470 ohm resistor and schottky diodeECO1000BR680 standard base, 680 ohm resistorECO1000BR680SD standard base, 680 ohm resistor and schottky diodeECO1000BR1000 standard base, 1000 ohm resistorECO1000BR1000SD standard base, 1000 ohm resistor and schottky diodeFL/B401 standard baseFL/1000B standard baseB501 standard analogue detector baseB501AP intelligent detector baseB524IEFT-1 analogue short circuit isolator baseB524HTR heater baseB524RTE latching relay baseBFA1 Standard Base

Talentum Developments LimitedBeal Lane, Shaw, Oldham, Lancashire OL2 8PF, United KingdomTel: +44 (0)1706 844714 • Fax: +44 (0)1706 882612E-mail: [email protected] • Website: www.talentum.co.uk

Certificate No: 729a to EN 54-10: 2002

Flame DetectorsCertificated Products LPCB Ref.

No.016589 Conventional IR 3 Flame Detector (007127) 729a/01

Note: Meets EN 54-10:2002 at Class 1 only

Page 290: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

280 31 Dec 2012

Certificated Products LPCB Ref. No.

016689 Analogue Addressable IR 3 Flame Detector (007127) 729a/02Note: Meets EN 54-10:2002 at Class 1 only

016579 Conventional IR 3 Intrinsically Safe Flame Detector (007127) 729a/03Note: Meets EN 54-10:2002 at Class 1 only

016679 Analogue Addressable IR 3 Intrinsically Safe Flame Detector (007127) 729a/04Note: Meets EN 54-10:2002 at Class 1 only

016519 Conventional IR 3 (Exd) Flameproof Flame Detector (007127) 729a/05Note: Meets EN 54-10:2002 at Class 1 only

016619 Analogue Addressable IR 3 (Exd) Flameproof Flame Detector (007127) 729a/06Note: Meets EN 54-10:2002 at Class 1 only

016581 Conventional IR2 Flame Detector (007127) 729a/07Note: Meets EN 54-10: 2002 at Class 1 only

016681 Analogue Addressable IR2 Flame Detector (007127) 729a/08Note: Meets EN 54-10: 2002 at Class 1 only

016571 Conventional IR2 Intrinsically Safe Flame Detector (007127) 729a/09Note: Meets EN 54-10: 2002 at Class 1 only

016511 Conventional IR2 (Exd) Flameproof Flame Detector (007127) 729a/10Note: Meets EN 54-10: 2002 at Class 1 only

016611 Analogue Addressable IR2 (Exd) Flameproof Flame Detector (007127) 729a/11Note: Meets EN 54-10: 2002 at Class 1 only

016591 Conventional UV/IR 2 Flame Detector (007127) 729a/12Note: Meets EN 54-10: 2002 at Class 1 only

016521 Conventional UV/IR 2 (Exd) Flameproof Flame Detector (007127) 729a/13Note: Meets EN 54-10: 2002 at Class 1 only

Ancillaries 007127 Mounting Bracket

Tamlite Emergency & FirePipers Road, Park Farm Industrial Estate, Redditch, Worcestershire B98 0HU, United KingdomTel: +44 (0)1527 510598 • Fax: +44 (0)1527 510592E-mail: [email protected] • Website: www.tamlite.co.uk

Certificate No: 928d to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.FSV-RR/FH Conventional Class P, heat detector (FSV-CDB base) 928d/02

Note: 1. Meets the requirements of EN 54-5 for Class A1R and Class B.

BaseFSV-CDB Universal adaptor base with resistor and Schottky diode

Certificate No: 928e to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.FSV-OPT/P Conventional photo smoke detector (FSV-CDB base) 928e/02

BaseFSV-CDB Universal adaptor base with resistor and Schottky diode

Page 291: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 281

Teledata S.r.l.Via Giulietti 8, Milan 20132, ItalyTel: +39 02-27201352 • Fax: +39 02-2593704E-mail: [email protected] • Website: www.teledate-i.com

Certificate No: 928a-(cl-6) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005Certificate No: 928d-(cl-6) to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.SF3500 Analogue addressable Class P heat detector with short circuit isolator

(BS100, BS100E, BS100/S and BS100E/S bases)928a/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

SF3500E Analogue addressable Class P heat detector lite(BS100, BS100E, BS100/S and BS100E/S bases)

928d/01

Note:1. Meets the requirements of EN 54-5 for Class A1R and Class B

BasesBS100 Universal adaptor baseBS100E Vega adaptor baseBS100/S Universal adaptor base with shorting clipBS100E/S Vega adaptor base with shorting clip

Certificate No: 928b-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928e-(cl-6) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 928f-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA 4021: 2003

Point Smoke DetectorsCertificated Products LPCB Ref.

No.SF1000 Analogue addressable photoelectric smoke detector with short circuit isolator

(BS100, BS100E, BS100/S and BS100E/S bases)928b/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

SF1000E Analogue addressable photoelectric smoke detector lite(BS100, BS100E, BS100/S and BS100E/S bases)

928e/01

Note:1. Meets the requirements of EN 54-7 at the following sensitivity settings:

Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

SF2000E Analogue addressable Class P heat and photoelectric smoke multi-sensor detector lite(BS100, BS100E, BS100/S and BS100E/S bases)

928f/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the

following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

Page 292: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

282 31 Dec 2012

Certificated Products LPCB Ref. No.

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

BasesBS100 Universal adaptor baseBS100E Vega adaptor baseBS100/S Universal adaptor base with shorting clipBS100E/S Vega adaptor base with shorting clip

Certificate No: 928c-(cl-6) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.SF2000 Analogue addressable Class P heat and photoelectric smoke multi-sensor detector with

short circuit isolator(BS100, BS100E, BS100/S and BS100E/S bases)

928c/01

Notes:1. Meets the requirements of EN 54-5 (Class A1) & EN 54-7 at the

following settings: Multi Criteria Level 1 (most sensitive) - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 2 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 3 - Thermally enhanced smoke detection with Class A1 heat response Multi Criteria Level 4 (least sensitive) - Thermally enhanced smoke detection with Class A1 heat response

2. Meets the requirements of EN 54-5 (Class A1R) at the following settings: Class A1R heat only response

3. Meets the requirements of EN 54-7 at the following settings: Optical only level 1 - High Optical only level 2 Optical only level 3 Optical only level 4 - Low

BasesBS100 Universal adaptor baseBS100E Vega adaptor baseBS100/S Universal adaptor base with shorting clipBS100E/S Vega adaptor base with shorting clip

Thorn Security Limited, trading as Tyco Safety ProductsDunhams Lane, Letchworth SG6 1BE, United KingdomTel: +44 (0)1462 667700 • Fax: +44 (0)1462 667777E-mail: [email protected] • Website: www.tycosafetyproducts-europe.com

Certificate No: 681c-(cl-1) to EN 54-5: 2000 + A1: 2002Certificate No: 681p-(cl-1) to EN 54-5: 2000 + A1: 2002 and EN 54-17: 2005

Heat DetectorsCertificated Products LPCB Ref.

No.801H MX Digital addressable Class P heat detector (4B, 4B-I and 5B bases) 681c/01

Page 293: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 283

Certificated Products LPCB Ref. No.

Note: 1. Meets EN54 Part 5 for classes A1R, A2S and CR.

601H-R Conventional Class A1R heat detector (4B, 4B-D and 5B bases) 681c/02601H-F Conventional Class A1S heat detector (4B, 4B-D and 5B bases) 681c/03MD601Ex Conventional intrinsically safe Class A1R rate of rise heat detector

(MUBEx base, 5BEx bases)681c/04

MD611Ex Conventional intrinsically safe Class A1S fixed temperature heat detector (MUBEx base, 5BEx base)

681c/05

816H MX Digital addressable Class P heat detector (4B, 4B-I and 5B bases) 681c/06Note: 1. Meets EN54 Part 5 for classes A1R, A2S and CR.

611H-F Conventional Class A1S fixed temperature heat detector(4B, 4B-D and 5B base)

681c/07

631H-F Conventional Class CS fixed temperature heat detector(4B, 4B-D and 5B base)

681c/08

840H MX digital addressable Class P heat detector (4B, 4B-I, and 5B bases) 681c/09Note:1. Approved with the following mode configurations:-- Heat detector at Class A1R- Heat detector at Class A2S- Heat detector at Class CR

830H MX digital addressable Class P heat detector (4B, 4B-I, and 5B bases) 681c/10Note:1. Approved with the following mode configurations:-- Heat detector at Class A1R- Heat detector at Class A2S- Heat detector at Class CR

850H MX digital addressable Class P heat detector (4B, 4B-C, and 5B bases)

681p/01

Note:1. Approved with the following mode configurations:-- Heat detector at Class A1R- Heat detector at Class A2S- Heat detector at Class CR

Bases:

4B 4" universal mounting base4B-C, 4” continuity base4B-D 4" diode mounting base4B-I, 4” isolator base5B 5” Universal mounting base5BEX Intrinsically safe detector baseMUBEx Intrinsically safe detector base

Certificate No: 681j-(cl-1) to EN 54-7: 2000 + AI: 2002 + A2: 2006 and CEA4021: 1999Certificate No: 681q-(cl-1) to EN 54-5: 2000 + A1:2002, EN 54-7: 2000 + A1:2002 + A2: 2006, LPS1274 Issue 1 and CEA 4021: 2003Certificate No: 681b-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 and CEA4021: 2003Certificate No: 681a-(cl-1) to EN 54-5: 2000 + A1: 2002 and Test Schedule 68297/29.0 Test schedule for Carbon Monoxide Fire DetectorsCertificate No: 681e-(cl-1) to EN 54-5: 2000 + A1: 2002 and LPS1265 Iss.1.0Certificate No: 681w-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006, EN 54-17: 2005 and CEA4021: 2003

Multi-criteria DetectorsCertificated Products LPCB Ref.

No.801CH MX Digital addressable Carbon Monoxide and Class P heat detector

(4B and 5B bases)681a/01

Notes:Approved with the following mode configurations:-1. Carbon monoxide detector at High and Normal sensitivity2. Rate of rise heat detector at Class A1R3. Fixed temperature heat detector at Class A2S4. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity5. Heat enhanced carbon monoxide fire detector at High and Normal sensitivity and rate of rise heat detector at Class A1R

Conditions of approval:

Page 294: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

284 31 Dec 2012

Certificated Products LPCB Ref. No.

1. The 801CH should only be installed in accordance with the manufacturers recommendations.2. The 801CH should not be set only as a carbon monoxide fire detector where there is a specific risk of rapid burning / flaming fires.3. Refer to technical publication 17A-02-DET for limitations on the use of carbon monoxide fire detection.

801PH MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I and 5B Bases)

681b/01

Note: Approved with the following mode configurations:-1. Optical smoke detector at High and Normal sensitivity2. Rate of rise heat detector at Class A1R3. Fixed temperature heat detector at Class A2S4. Heat enhanced optical smoke detector at High and Normal sensitivity5. Optical smoke detector using FastLogic at High and Normal sensitivity6. Heat enhanced optical smoke detector using FastLogic at High and Normal sensitivity

840PC MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector (4B, 4B-I, and 5B bases)

681b/02

Notes:1. Approved with the following mode configurations:-- UNIV Universal optical smoke and A2S heat multi-criteria detector- RESIL Resilient optical smoke and A2S heat multi-criteria detector- Heat detector at Class A1R- HPO Heat enhanced optical smoke detector at Normal sensitivity

2. The Carbon Monoxide toxic gas/CCO modes are not approved830PC MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide

detector (4B, 4B-I, and 5B bases)681b/03

Notes:1. Approved with the following mode configurations:-- UNIV Universal optical smoke and A2S heat multi-criteria detector- RESIL Resilient optical smoke and A2S heat multi-criteria detector- Heat detector at Class A1R- HPO Heat enhanced optical smoke detector at Normal sensitivity

2. The Carbon Monoxide toxic gas/CCO modes are not approved840PH MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I, and

5B bases)681b/04

Note:Approved with the following mode configurations:-- Heat detector at Class A1R

- Heat detector at Class A2S- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic.

830PH MX digital addressable photoelectric smoke and Class P heat detector (4B, 4B-I, and 5B bases)

681b/05

Note:Approved with the following mode configurations:-- Heat detector at Class A1R

- Heat detector at Class A2S- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using FastLogic.

601CH Conventional Class A1R thermally enhanced Carbon Monoxide detector (4B, 4B-D and 5B Bases)

681e/01

601PH Conventional high performance photoelectric smoke detector (4B, 4B-D and 5B bases) 681j/01MR601Tex Conventional intrinsically safe high performance photoelectric smoke detector with heat

enhancement (MUBEx base, 5BEx bases)681j/02

816PH MX Digital addressable photoelectric detector with heat enhancement (4B and 5B bases) 681j/03Note: 1. Meets EN54 Part 7 at Normal sensitivity

801PC Analogue addressable combined optical, heat and CO fire detector(4B, 5B and DHM-5B bases)

681q/01

Page 295: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 285

Certificated Products LPCB Ref. No.

Notes: 1. Certificated at the following modes: Mode 0 - Universal multi-criteria (smoke /heat/CO) wide spectrum fire detection with Class A2S heat detection Mode 1 - Multi-criteria (smoke /heat/CO) fire detection with high false alarm immunity with Class A2S heat detection Mode 2 - Class A1R heat detection Mode 3 - Thermally enhanced smoke detection Mode 4 - Thermally enhanced CO detection2. Meets the requirements of LPS 1274 at modes 0 and 4, CEA 4021 and EN 54-7 at modes 0, 1 and 3, and EN 54-5 at modes 0, 1, and 2.

811PC Analogue addressable combined optical, heat and CO fire detector ( marine version)(4B, 5B and DHM-5B bases)

681q/02

Notes: 1. Certificated at the following modes: Mode 0 - Universal multi-criteria (smoke /heat/CO) wide spectrum fire detection with Class A2S heat detection Mode 1 - Multi-criteria (smoke /heat/CO) fire detection with high false alarm immunity with Class A2S heat detection Mode 2 - Class A1R heat detection Mode 3 - Thermally enhanced smoke detection Mode 4 - Thermally enhanced CO detection2. Meets the requirements of LPS 1274 at modes 0 and 4, CEA 4021 and EN 54-7 at modes 0, 1 and 3, and EN 54-5 at modes 0, 1, and 2.

850PC MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide detector with short circuit isolator (4B, 4B-C and 5B bases)

681w/01

Notes:1. Approved with the following mode configurations:-- UNIV Universal optical smoke and A2S heat multi-criteria detector- RESIL Resilient optical smoke and A2S heat multi-criteria detector- Heat detector at Class A1R- HPO Heat enhanced optical smoke detector at Normal sensitivity

2. The Carbon Monoxide toxic gas/CCO modes are not approved851PCN MX digital addressable photoelectric smoke, Class P heat and Carbon Monoxide

detector with short circuit isolator [Ex(N) version] (4B-EN base) 681w/02

Notes:1. Approved with the following mode configurations:-- UNIV Universal optical smoke and A2S heat multi-criteria detector- RESIL Resilient optical smoke and A2S heat multi-criteria detector- Heat detector at Class A1R- HPO Heat enhanced optical smoke detector at Normal sensitivity

2. The Carbon Monoxide toxic gas/CCO modes are not approved850PH MX digital addressable photoelectric smoke and Class P heat detector with short circuit

isolator (4B, 4B-C, and 5B bases) 681w/03

Note: Approved with the following mode configurations:- - Heat detector at Class A1R- Heat detector at Class A2S- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using

FastLogic.851PH MX digital addressable photoelectric smoke and Class P heat detector with short circuit

isolator [Marine version] (4B, 4B-C, and 5B bases)681w/04

Note:1. Approved with the following mode configurations:- - Heat detector at Class A1R- Heat detector at Class A2S- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using

FastLogic.851PHN MX digital addressable photoelectric smoke and Class P heat detector with short circuit

isolator [Ex(N) version] (4B-EN base)681w/05

Note:1. Approved with the following mode configurations:- - Heat detector at Class A1R

Page 296: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

286 31 Dec 2012

Certificated Products LPCB Ref. No.

- Heat detector at Class A2S- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic- HPO Heat enhanced optical smoke at High, Normal and Low sensitivity- FL HPO Heat enhanced optical smoke at High, Normal and Low sensitivity using

FastLogic.

Bases:4B 4” universal mounting base4B-C 4” continuity base4B-D Diode mounting base4B-D 4" Diode mounting base4B-EN 4” Ex{N} compliant mounting base4B-I, 4” isolator base5B 5” Universal mounting base5BEx Intrinsically safe mounting baseMUB Universal mounting baseMUBEx intrinsically safe detector baseDHM-5B - Deck head mounting adaptor for 5" base

Certificate No: 763a to EN 54-10: 2002Certificate No: 681r-(cl-1) to EN 54-10: 2002Certificate No: 018e-(cl-1) to EN 54-10: 2001+ A1:2005

Flame DetectorsCertificated Products LPCB Ref.

No.S231i+ Class 1, conventional 2-wire intrinsically safe IR flame detector 018e/01S231f+ Class 1, conventional 2-wire flame proof IR flame detector 018e/02S241i+ Class 1, 4-20mA intrinsically safe IR flame detector 018e/03S241f+ Class 1, 4-20mA flame proof IR flame detector 018e/04S251i+ Class 1, analogue addressable intrinsically safe IR flame detector 018e/05S251f+ Class 1, analogue addressable flame proof IR flame detector 018e/06S261f+ Class 1, relay flame proof IR flame detector 018e/07S271f+ Class 1, analogue addressable intrinsically safe triple IR flame detector with MX interface 018e/08S271i+ Class 1, analogue addressable flame proof triple IR flame detector with MX interface 018e/09601F Conventional Class 2 flame detector (4B, 4B-D and 5B bases) 681r/01601FEx Conventional Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases) 681r/02801F MX addressable Class 2 flame detector (4B and 5B bases) 681r/03801FEx MX addressable Class 2 intrinsically safe flame detector (MUBEx and 5BEx bases) 681r/04S231i+ Conventional class 1 2-wire intrinsically safe IR flame detector 763a/01S231f+ Conventional class 1 2-wire flame proof IR flame detector 763a/02S241i+ 4-20mA current class 1 intrinsically safe IR flame detector 763a/03S241f+ 4-20mA current class 1 flame proof IR flame detector 763a/04S251i+ Analogue addressable class 1 intrinsically safe IR flame detector 763a/05S251f+ Analogue addressable class 1 flame proof IR flame detector 763a/06S261f+ Relay class 1 flame proof IR flame detector 763a/07S271i+ Analogue class 1 triple IR flame detector with MX interface 763a/08S271f+ Analogue class 1 flame proof triple IR flame detector with MX interface 763a/09

Bases:4B 4” standard mounting base4B-D 4” diode mounting base5B standard mounting baseMUBEx Intrinsically safe mounting base5BEx Intrinsically safe mounting baseMUB standard mounting base5B standard mounting base5BI addressable isolator base

Certificate No: 681d-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006Certificate No: 681z-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Smoke DetectorsCertificated Products LPCB Ref.

No.801I MX Digital addressable ionisation smoke detector (4B, 4B-I and 5B bases) 681d/01

Page 297: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 287

Certificated Products LPCB Ref. No.

Note: 1. Meets EN54 Part 7 at High and Normal Sensitivity

601I Conventional ionisation smoke detector (4B, 4B-D and 5B bases) 681d/02601P Conventional optical smoke detector (4B, 4B-D and 5B bases) 681d/03816P MX Digital addressable photoelectric smoke detector

(4B, 4B-I and 5B bases)681d/05

Note: 1. Meets EN54 Part 7 at High and Normal Sensitivity

840P MX digital addressable photoelectric smoke detector (4B, 4B-I, and 5B bases)

681d/06

Note:1. Approved with the following mode configurations:-- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic

830P MX digital addressable photoelectric smoke detector (4B, 4B-I, and 5B bases)

681d/07

Note:1. Approved with the following mode configurations:-- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic

850P MX digital addressable photoelectric smoke detector with short circuit isolator (4B, 4B-C and 5B bases)

681z/01

Note:1. Approved with the following mode configurations:-- OPT Optical smoke detector at High, Normal and Low sensitivity- FL OPT Optical smoke detector at High, Normal and Low sensitivity using FastLogic

Bases:

4B 4" universal mounting base4B-C, 4” continuity base4B-D Diode mounting base4B-I, 4” isolator base5B 5” Universal mounting base

Certificate No: 681aa-(cl-1) to EN 54-17: 2005

Isolating baseCertificated Products LPCB Ref.

No.4B-I Short circuit isolator base 681aa/01

UniPOS Ltd47 San Stefano Street, Pleven, BulgariaTel: +359 64 891124E-mail: [email protected] • Website: www.unipos-bg.com

Certificate No: 1107a to EN 54-5: 2000 A1: 2002

Certificated Products LPCB Ref. No.

FD7120 Analogue addressable rate of rise heat detector (7100 base) 1107a/01Note:Meets the requirements of EN 54-5 at Class A2R

FD8020 Conventional rate-of-rise heat detector (8000 base) 1107a/02Note:Meets the requirements of EN 54-5 at Class A2R

Bases7100 standard analogue detector base8000 standard conventional detector base

Page 298: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

288 31 Dec 2012

Certificate No: 1107b to EN 54-7: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

FD7130 Analogue addressable optical smoke detector (7100 base) 1107b/01Note: Meets the requirements of EN 54-7 in the normal sensitivity setting.

FD8030 Conventional optical smoke detector (8000 base) 1107b/02Note: Meets the requirements of EN 54-7 in the normal sensitivity setting.

Bases7100 standard analogue detector base8000 standard conventional detector base

Certificate No: 1107c to EN 54-5: 2000 + A1: 2002, EN 54-7: 2001 + A1: 2002 + A2: 2006 & CEA 4021: July 2003

Certificated Products LPCB Ref. No.

FD7160 Analogue addressable combined heat & optical smoke detector (7100 base) 1107c/01Note: Meets the requirements of EN 54-5: 2000 (Class A2R) & EN54-7: 2000 at default normal sensitivity setting.

FD8060 Conventional combined heat & optical smoke detector (8000 base) 1107c/02Note:Meets the requirements of EN 54-5: 2000 (Class A2R) & EN54-7: 2000 at default normal sensitivity setting.

Bases 7100 standard analogue detector base8000 standard conventional detector base

UTC Fire & Security BVKelvinstraat 7, NL-6003DH, Weert, The NetherlandsTel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com

Certificate No: 092p-(cl-1) to EN 54-5: 2000 + A1: 2002

Certificated Products LPCB Ref. No.

EA20E-3 Analogue addressable Class P heat detector(ZP7-SB1 base) (Labelled EST)

092p/01

Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.

PRRPHDI2004 Analogue addressable Class P heat detector(ZP7-SB1 base) (Labelled Photain Controls)

092p/01

Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.

T-17003 Analogue addressable Class P heat detector(ZP7-SB1 base) (Labelled Plana Fabrega)

092p/01

Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.

ZP720-3 Analogue addressable Class P heat detector(ZP7-SB1 base) (Labelled Ziton)

092p/01

Note: 1. Approved for use at Heat Class sensitivity settings 1 (Class A2) and 2 (Class A1) only.

E620-581-3 Conventional Class A1 heat detector(E6-BS1 base) (Labelled EST)

092p/02

Z620-581-3 Conventional Class A1 heat detector(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)

092p/02

E620-582-3 Conventional Class A1R heat detector(E6-BS1 base) (Labelled EST)

092p/03

PRRP2004 Conventional Class A1R heat detector 092p/03

Page 299: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 289

Certificated Products LPCB Ref. No.

(FSBP2000 base) (Labelled Photain Controls)TV-7003 Conventional Class A1R heat detector

(BD-21 & BD-22 bases) (Labelled Plana Fabrega)092p/03

Z620-582-3 Conventional Class A1R heat detector(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)

092p/03

E620-771-3 Conventional Class B heat detector(E6-BS1 base) (Labelled EST)

092p/04

PHDP2004HT Conventional Class B heat detector(FSBP2000 base) (Labelled Photain Controls)

092p/04

Z620-771-3 Conventional Class B heat detector(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)

092p/04

Bases

ZP7-SB1 Standard base Z6-BS1 Conventional surface baseE6-BS1 Conventional surface baseBD-21 Conventional surface baseFSBP2000 Conventional surface baseZ6-BS5 Conventional diode baseBD-22 Conventional diode base

Certificate No: 092n-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

EA10E-2 Analogue addressable ionisation smoke detector(ZP7-SB1 base) (Labelled EST)

092n/01

Note: 1. Approved for use at Standard sensitivity setting only.

I-17001 Analogue addressable ionisation smoke detector(ZP7-SB1 base) (Labelled Plana Fabrega)

092n/01

Note: 1. Approved for use at Standard sensitivity setting only.

ISDI2000 Analogue addressable ionisation smoke detector(ZP7-SB1 base) (Labelled Photain Controls)

092n/01

Note: 1. Approved for use at Standard sensitivity setting only.

ZP710-2 Analogue addressable ionisation smoke detector(ZP7-SB1 base) (Labelled Ziton)

092n/01

Note: 1. Approved for use at Standard sensitivity setting only.

EA30E-2 Analogue addressable photoelectric smoke detector(ZP7-SB1 base) (Labelled EST)

092n/02

Note: 1. Approved for use at Standard sensitivity setting only.

O-17002 Analogue addressable photoelectric smoke detector(ZP7-SB1 base) (Labelled Plana Fabrega)

092n/02

Note: 1. Approved for use at Standard sensitivity setting only.

PPDI2000 Analogue addressable photoelectric smoke detector(ZP7-SB1 base) (Labelled Photain Controls)

092n/02

Note: 1. Approved for use at Standard sensitivity setting only.

ZP730-2 Analogue addressable photoelectric smoke detector(ZP7-SB1 base) (Labelled Ziton)

092n/02

Note: 1. Approved for use at Standard sensitivity setting only.

E610-3 Conventional ionisation smoke detector(E6-BS1 base) (Labelled EST)

092n/03

Z610-3 Conventional ionisation smoke detector(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)

092n/03

E630-3 Conventional photoelectric smoke detector(E6-BS1 base) (Labelled EST)

092n/04

O-7002 Conventional photoelectric smoke detector(BD-21 & BD-22 bases) (Labelled Plana Fabrega)

092n/04

PPDP2004 Conventional photoelectric smoke detector(FSBP2000 base) (Labelled Photain Controls)

092n/04

Z630-3 Conventional photoelectric smoke detector(Z6-BS1 & Z6-BS5 bases) (Labelled Ziton)

092n/04

Page 300: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

290 31 Dec 2012

Bases

ZP7-SB1 Standard base Z6-BS1 Conventional surface baseE6-BS1 Conventional surface baseBD-21 Conventional surface baseFSBP2000 Conventional surface baseZ6-BS5 Conventional diode baseBD-22 Conventional diode base

Certificate No: 092k-(cl-1) to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Certificated Products LPCB Ref. No.

EA32E-2 Analogue addressable combined photoelectric smoke and heat detector. (Labelled EST) (ASBE-2 base)

092k/01

Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5.

EAS707 Analogue addressable combined photoelectric smoke and heat detector. (Labelled EEC) (ZP7-SB1 base)

092k/01

Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5.

OT-17004 Analogue addressable combined photoelectric smoke and heat detector. (Labelled Plana Fabrega) (ZP7-SB1 base)

092k/01

Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7 and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5.

PPDPHDI2000 Analogue addressable combined photoelectric smoke and heat detector. (Labelled Photain Controls) (ZP7-SB1 base)

092k/01

Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5.

ZP732-2 Analogue addressable combined photoelectric smoke and heat detector. (Labelled Ziton) (ZP7-SB1 base)

092k/01

Note: 1. Certificated at sensitivity profiles 1-4 for EN 54:7and sensitivity profiles 5 (A1) and 6(A2) for EN 54:5.

Bases

ZP7-SB1 Standard base ASBE-2 Standard base

UTC Fire & Security Inc. Trading as Edwards Systems Technology8985 Town Center Parkway, Bradenton, Florida FL34202, USATel: 941 739-42228Website: www.fs.utc.com

Certificate No: 262s-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.SIGA-IPHSI Intelligent analogue addressable thermally enhanced photoelectric and ionisation smoke

detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 & SIGA-AB4G bases)

262s/01

Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases

Page 301: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 291

Certificated Products LPCB Ref. No.

SIGA-PHSI Intelligent analogue addressable thermally enhanced photoelectric smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262s/02

Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft. 2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases

Bases:

SIGI-IBS Isolator baseSIGA-SB Standard baseSIGA-SB4 Standard base with trim skirtSIGA-RB Relay baseSIGA-RB4 Relay base with trim skirtSIGA-IB Isolator BaseSIGA-IB4 Isolator base with 4 inch mounting adaptorsSIGA-AB4G Sounder base

Accessories:

SIGA-LED Indicator

Certificate No: 262t-(cl-1) to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.SIGA-ISI Intelligent analogue addressable ionisation smoke detector

(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262t/01

Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases

SIGA-PSI Intelligent analogue addressable photoelectric smoke detector (SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262t/02

Notes: 1. Meets the requirements of EN 54-7:2000 at sensitivity settings 1.0%/ft, 2%/ft, 2.5%/ft, 3%/ft, and 3.5%/ft.2. The SIGA-LED indicator is approved for use with the SIGA-SB and SIGA-SB4 bases

Bases:

SIGI-IBS Isolator baseSIGA-SB Standard baseSIGA-SB4 Standard base with trim skirtSIGA-RB Relay baseSIGA-RB4 Relay base with trim skirtSIGA-IB Isolator BaseSIGA-IB4 Isolator base with 4 inch mounting adaptorsSIGA-AB4G Sounder base

Accessories:

SIGA-LED Indicator

Certificate No: 262u-(cl-1) to EN 54-5: 2000 + A1: 2002.

Page 302: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

292 31 Dec 2012

Point Heat DetectorsCertificated Products LPCB Ref.

No.SIGA-HRSI Intelligent analogue addressable Class A1 & A2R rate of rise heat detector

(SIGI-IBS, SIGA-SB, SIGA-SB4, SIGA-RB, SIGA-RB4,SIGA-IB, SIGA-IB4 and SIGA-AB4G bases)

262u/02

Note: 1. The SIGA-LED indicator is also approved for use with the SIGA-SB and SIGA-SB4 bases

Bases:

SIGI-IBS Isolator baseSIGA-SB Standard baseSIGA -SB4 Standard base with trim skirtSIGA -RB Relay baseSIGA -RB4 Relay base with trim skirtSIGA-IB Isolator BaseSIGA-IB4 Isolator base with 4 inch mounting adaptorsSIGA-AB4G Sounder base

Accessories:

SIGA-LED Indicator

VRC Terofire ProductsLion House, Lion Street, Congleton, Cheshire CW12 4BH, United KingdomTel: +44 (0)1260 297578 • Fax: +44 (0)1260 290078E-mail: [email protected]

Certificate No: 512d to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.10-0003 Conventional 2 wire 24VDC class A2S fixed temperature and rate-of-rise heat detector

with LED output (P/N854001 base)512d/03

10-0003 Conventional 2 wire 24VDC class A2R fixed temperature and rate-of-rise heat detector with LED output (P/N854001 base)

512d/04

Bases:P/N854001 4-Wire detector base

Certificate No: 512a to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.10-0001 Conventional 2 wire photoelectric smoke detector with remote LED output (P/N854001

base)512a/02

BaseP/N854001 4-Wire detector base

Certificate No: 512b to EN 54-5: 2000 + A1: 2002, EN 54-7: 2000 + A1: 2002 + A2: 2006 & CEA 4021: 2003

Multi-Criteria DetectorsCertificated Products LPCB Ref.

No.10-0002 Conventional 2 wire photoelectric smoke and heat detector with remote LED output

(P/N854001 base)512b/02

Base

Page 303: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 293

P/N854001 4-Wire detector base

Wagner Group GmbHSchleswigstraße 5, D-30853 Langenhagen, GermanyTel: +49 511 97383 0 • Fax: +49 511 73338 6E-mail: [email protected] • Website: www.wagner.de

Certificate No: 524c to EN 54-20: 2006

Aspirating Smoke DetectorsCertificated Products LPCB Ref.

No.TITANUS PRO-SENS 524c/01

Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations (Class A, Class B and Class C): TP-1/a (standard version, no bargraph display, 1 alarm, not available for

networking) TP-1-F/a (deep freeze version, no bargraph display, 1 alarm, not available for

networking ) TP-1-SL (silent version, no bargraph display, 1 alarm, not available for

networking)

3. The approved detector must incorporate one or two of the following detector modules: DM-TP-01-L (standard version, sensitivity of 0.015%/m) DM-TP-01-L-F (deep freeze version, sensitivity of 0.015%/m) DM-TP-10-L (standard version, sensitivity of 0.10%/m) DM-TP-10-L-F (deep freeze version, sensitivity of 0.10%/m) DM-TP-50-L (standard version, sensitivity of 0.50%/m) DM-TP-50-L-F (deep freeze version, sensitivity of 0.50%/m)

TITANUS PRO-SENS/net 524c/02Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations (Class A, Class B and Class C): TP-3 (standard version, no bargraph display, 1 alarm, prepared for networking) TP-3-F (deep freeze version, no bargraph display, 1 alarm, prepared for

networking) TP-3-SL (silent version, no bargraph display, 1 alarm, prepared for networking) TP-4 (standard version, no bargraph display, 2 alarms, prepared for

networking) TP-4-F (deep freeze version, no bargraph display, 2 alarms, prepared for

networking) TP-4-SL (silent version, no bargraph display, 2 alarms, prepared for

networking) TP-5 (standard version, no bargraph display, 3 alarms, prepared for

networking) TP-5-F (deep freeze version, no bargraph display, 3 alarms, prepared for

networking)

Page 304: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

294 31 Dec 2012

Certificated Products LPCB Ref. No.

TP-5-SL (silent version, no bargraph display, 3 alarms, prepared for networking)

3 The approved detector must incorporate one or two of the following detector modules: DM-TT-01-L (standard version, sensitivity of 0.015%/m) DM-TT-01-L-F (deep freeze version, sensitivity of 0.015%/m) DM-TT-10-L (standard version, sensitivity of 0.10%/m) DM-TT-10-L-F (deep freeze version, sensitivity of 0.10%/m) DM-TT-50-L (standard version, sensitivity of 0.50%/m) DM-TT-50-L-F (deep freeze version, sensitivity of 0.50%/m)

TITANUS TOP-SENS 524c/03Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations (Class A, Class B and Class C): TT-1/a (standard version, bargraph display, 3 alarms, prepared for networking) TT-1-F/a (deep freeze version, bargraph display, 3 alarms, prepared for

networking) TT-1-SL (silent version, bargraph display, 3 alarms, prepared for networking)

3. The approved detector must incorporate one or two of the following detector modules: DM-TT-01-L (standard version, sensitivity of 0.015%/m) DM-TT-01-L-F (deep freeze version, sensitivity of 0.015%/m) DM-TT-10-L (standard version, sensitivity of 0.10%/m) DM-TT-10-L-F (deep freeze version, sensitivity of 0.10%/m) DM-TT-50-L (standard version, sensitivity of 0.50%/m) DM-TT-50-L-F (deep freeze version, sensitivity of 0.50%/m)

TITANUS MICRO-SENS 524c/04Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations, sensitivity of 0.10%/m (Class A, Class B and Class C): DM-TM-10 (standard version) DM-TM-R-10 (version with ROOM IDENT) DM-TM-B-10 (version with bargraph display) DM-TM-RB-10 (version with ROOM IDENT, bargraph display) DM-TM-Z-10 (version with redundancy fan) DM-TM-ZB-10 (version with redundancy fan, bargraph display) DM-TM-10-F (deep freeze version) DM-TM-B-10-F (version with bargraph display, deep freeze) DM-TMV-10 (version with 2 stages of alarm) DM-TMV-R-10 (version with 2 stages of alarm, ROOM IDENT) DM-TMV-B-10 (version with 2 stages of alarm, bargraph display) DM-TMV-RB-10 (version with 2 stages of alarm, ROOM IDENT, bargraph

display) DM-TMV-10-F (version with 2 stages of alarm, deep freeze) DM-TMV-B-10-F (version with 2 stages of alarm, bargraph display, deep

freeze) DM-MB-TM-10 (version without fan to be used as detector box) DM-MB-TM-B-10 (version without fan to be used as detector box, bargraph

display)

Page 305: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 295

Certificated Products LPCB Ref. No.

3. Approved detector configurations, sensitivity of 0.50%/m (Class A, Class B and Class C): DM-TM-50 (standard version) DM-TM-R-50 (version with ROOM IDENT) DM-TM-B-50 (version with bargraph display) DM-TM-RB-50 (version with ROOM IDENT, bargraph display) DM-TM-Z-50 (version with redundancy fan) DM-TM-ZB-50 (version with redundancy fan, bargraph display) DM-TM-50-F (deep freeze version) DM-TM-B-50-F (version with bargraph display, deep freeze) DM-TMV-50 (version with 2 stages of alarm) DM-TMV-R-50 (version with 2 stages of alarm, ROOM IDENT) DM-TMV-B-50 (version with 2 stages of alarm, bargraph display) DM-TMV-RB-50 (version with 2 stages of alarm, ROOM IDENT, bargraph

display) DM-TMV-50-F (version with 2 stages of alarm, deep freeze) DM-TMV-B-50-F (version with 2 stages of alarm, bargraph display, deep

freeze) DM-MB-TM-50 (version without fan to be used as detector box) DM-MB-TM-B-50 (version without fan to be used as detector box, bargraph

display)

TITANUS RACK-SENS 524c/05Notes:1. Approval of the detector is conditional upon the following requirements:

For compliance with Clause 5.10 of EN 54-20: 2006, the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4.

System design, installation and commissioning shall be performed in accordance with the manufacturer’s installation guide, associated manuals and design software TF-SC-1.

The detector shall be installed with sampling pipe conforming to EN 61386-1, to at least Class 1131.

2. Approved detector configurations (Class A, Class B and Class C): TR1-10 (placed in a ‘1U’ housing, sensitivity of 0.10%/m) TR1-50 (placed in a ‘1U’ housing, sensitivity of 0.50%/m) TR2-10 (placed in a ‘2U’ housing, sensitivity of 0.10%/m) TR2-50 (placed in a ‘2U’ housing, sensitivity of 0.50%/m)

Xtralis Pty Limited4 North Drive, Virginia Park, 236-262 East Boundary Road, East Bentleigh, Victoria 3165, AustraliaTel: +61 3 9936 7001, +44 (0)1442 242330 • Fax: +61 3 9936 7201E-mail: [email protected] • Website: www.xtralis.com

European Operations at:Xtralis (UK) Limited, Vision House, Focus 31, Mark Road, Hemel Hempstead, Hertfordshire HP2 7BW, United KingdomTel: +44 (0)1442 242330 • Fax: +44 (0)1442 249327

Certificate No: 305e to EN 54-20: 2006Certificate No: 305d to EN 54-20: 2006Certificate No: 305g to EN 54-20: 2006

Aspirating Smoke DetectorsCertificated Products LPCB Ref.

No.VESDA VLF-250-xx (VLF-250-01NF*) high sensitivity

Incorporating the following ancillary equipment: - VIC-010 VESDAnet network card

305d/01

Page 306: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

296 31 Dec 2012

Certificated Products LPCB Ref. No.

aspirating smoke detector - VIC-020 Multifunction control card- VIC-030 Multifunction control card- VRT-V00 Remote VLF display (with 7 relays) - VRT-W00 Remote VLF display (no relays)- VRT-500 Remote relay unit (with 7 relays)Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07208).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels.

7. Alternative model number with suffix* as indicated, intended for French market.

8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLF-500-xx (VLF-500-01NF*) high sensitivity aspirating smoke detector

Incorporating the following ancillary equipment: - VIC-010 VESDAnet network card - VIC-020 Multifunction control card- VIC-030 Multifunction control card- VRT-V00 Remote VLF display (with 7 relays)- VRT-W00 Remote VLF display (no relays)- VRT-500 Remote relay unit (with 7 relays)

305d/02

Notes:1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07209).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels.

7. Alternative model number with suffix* as indicated, intended for French market.

8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLC High sensitivity aspirating smoke detector

Approved configurations: - VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version- VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version- VLC-400 (VLF-400-NF*) VLC Apollo (AP) version- VLC-700 (801519.F0*) VLC Esser (EB) version- VLC-800 (VLF-800-NF*) VLC Tyco (MX) versionApproved remote units with the VLC-505 VESDAnet (VN) version: - VRT-J00 Remote VLC display (with 7 relays)- VRT-K00 Remote VLC display (no relays)- VRT-500 Remote relay unit (with 7 relays)

305d/03

Notes:1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLC product guides (10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700], 09515 [VLC-800]).

Page 307: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 297

Certificated Products LPCB Ref. No.

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. Alternative model numbers with suffix* as indicated, intended for French market.

7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLP High sensitivity aspirating smoke detector

Approved Configurations:VLP-012 (VLP-01200-NF*) VLP detector with Display & ProgrammerVLP-002 (VLP-00200-NF*) VLP detector with DisplayVLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs onlyVLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDsVLP-100 VLP detector with OEM coverApproved remote units:VRT-100 Remote ProgrammerVRT-200 Remote VLP Display unit (with 7 relays)VRT-300 VESDAnet socketVRT-500 Remote Relay unit (with 7 relays)VRT-600 Remote VLP Display unit (without relays)

305d/04

Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLP product guide (10278).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. Alternative model numbers with suffix* as indicated, intended for French market.

7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLS High sensitivity aspirating smoke detector

Approved Configurations:VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDsVLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display ModuleVLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program ModuleVLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDsVLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display ModuleVLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program ModuleVLS-100 VLS with 7 Relays and OEM coverVLS-500 VLS with 12 Relays and OEM coverApproved Remote Units:VRT-400 Remote Scanner Display with 7 relaysVRT-700 Remote Scanner Display with no relaysVRT-800 Remote Scanner Display with 12 relaysVRT-900 Remote Scanner Relays -12 relaysVRT-E00 Remote Scanner Relays - 7 relays

305d/05

Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLS product guide (10279).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. Alternative model numbers with suffix* as indicated, intended for French market.

7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be

Page 308: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

298 31 Dec 2012

Certificated Products LPCB Ref. No.

sought and the recommendations followedVESDA VLF-250-xx (VLF-250-01NF*) high sensitivity aspirating smoke detector

Incorporating the following ancillary equipment: - VIC-010 VESDAnet network card- VIC-020 Multifunction control card- VIC-030 Multifunction control card- VRT-V00 Remote VLF display (with 7 relays) - VRT-W00 Remote VLF display (no relays)- VRT-500 Remote relay unit (with 7 relays)

305d/06

Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07208).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels.

7. Alternative model number with suffix* as indicated, intended for French market.

8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLF-500-xx (VLF-500-01NF*) high sensitivity aspirating smoke detector

Incorporating the following ancillary equipment: - VIC-010 VESDAnet network card - VIC-020 Multifunction control card- VIC-030 Multifunction control card- VRT-V00 Remote VLF display (with 7 relays)- VRT-W00 Remote VLF display (no relays)- VRT-500 Remote relay unit (with 7 relays)

305d/07

Notes:1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLF product guide (07209).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. xx denotes alternative language version where xx (range 00 to 99) designates the language of the product labels.

7. Alternative model number with suffix* as indicated, intended for French market.

8. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLC High sensitivity aspirating smoke detector

Approved configurations: - VLC-500 (VLF-50000-NF*) VLC Relays only (RO) version- VLC-505 (VLF-50500-NF*) VLC VESDAnet (VN) version- VLC-400 (VLF-400-NF*) VLC Apollo (AP) version- VLC-700 (801519.F0*) VLC Esser (EB) version- VLC-800 (VLF-800-NF*) VLC Tyco (MX) versionApproved remote units with the VLC-505 VESDAnet (VN) version: - VRT-J00 Remote VLC display (with 7 relays)- VRT-K00 Remote VLC display (no relays)- VRT-500 Remote relay unit (with 7 relays)

305d/08

Notes:1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in

Page 309: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 299

Certificated Products LPCB Ref. No.

accordance with the VESDA VLC product guides (10280 [VLC-500 & VLC-505], 03494 [VLC-400], 09411 [VLC-700], 09515 [VLC-800]).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. Alternative model numbers with suffix* as indicated, intended for French market.

7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLP High sensitivity aspirating smoke detector

Approved Configurations:VLP-012 (VLP-01200-NF*) VLP detector with Display & ProgrammerVLP-002 (VLP-00200-NF*) VLP detector with DisplayVLP-400 (VLP-00000-NF*) VLP detector with Fire/OK LEDs onlyVLP-401 (VLP-00100-NF*) VLP detector with Programmer & Fire/OK LEDsVLP-100 VLP detector with OEM coverApproved remote units:VRT-100 Remote ProgrammerVRT-200 Remote VLP Display unit (with 7 relays)VRT-300 VESDAnet socketVRT-500 Remote Relay unit (with 7 relays)VRT-600 Remote VLP Display unit (without relays)

305d/09

Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLP product guide (10278).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. Alternative model numbers with suffix* as indicated, intended for French market.

7. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VESDA VLS High sensitivity aspirating smoke detector

Approved Configurations:VLS-600 (VLS-20000-NF*) VLS with 7 relays and Fire/OK LEDsVLS-204 (VLS-20400-NF*) VLS with 7 Relays and Display ModuleVLS-214 (VLS-21400-NF*) VLS with 7 Relays, Display and Program ModuleVLS-700 (VLS-30000-NF*) VLS with 12 relays and Fire/OK LEDsVLS-304 (VLS-30400-NF*) VLS with 12 Relays and Display ModuleVLS-314 (VLS-31400-NF*) VLS with 12 Relays, Display and Program ModuleVLS-100 VLS with 7 Relays and OEM coverVLS-500 VLS with 12 Relays and OEM coverApproved Remote Units:VRT-400 Remote Scanner Display with 7 relaysVRT-700 Remote Scanner Display with no relaysVRT-800 Remote Scanner Display with 12 relaysVRT-900 Remote Scanner Relays -12 relaysVRT-E00 Remote Scanner Relays - 7 relays

305d/10

Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector shall be supplied

with power from a power supply conforming to the requirements of EN 54-4.2. The device is approved for sensitivity Classes A, B and C. The Class of any

pipe/hole configuration and detector sensitivity must be determined using ASPIRE2.

3. System design, installation and commissioning shall be performed in accordance with the VESDA VLS product guide (10279).

4. Remote display, programmer and relay modules are also approved in a 19 sub rack.

5. The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

6. Alternative model numbers with suffix* as indicated, intended for French

Page 310: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

300 31 Dec 2012

Certificated Products LPCB Ref. No.

market.7. When installing pipework systems containing in-line components, guidance

from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed

XCC-010 Xtralis Class C aspirating smoke detector 305e/01Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector

shall be supplied with power from a power supply conforming with the requirements of EN 54-4.

2. System design, installation and commissioning shall be performed In accordance with the Xtralis Class C product guide (Document 14159).

3. The device is approved for sensitivity Class C.4. The detector is also approved when used with in-line filter models,

E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

5. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

XCC-010 Xtralis Class C aspirating smoke detector 305e/02Notes: 1. For compliance with clause 5.10 of EN 54-20 the detector

shall be supplied with power from a power supply conforming with the requirements of EN 54-4.

2. System design, installation and commissioning shall be performed In accordance with the Xtralis Class C product guide (Document 14159).

3. The device is approved for sensitivity Class C.4. The detector is also approved when used with in-line filter models,

E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785).

5. When installing pipework systems containing in-line components, guidance from the 18336 "Xtralis Open-flow In-Line Components" document shall be sought and the recommendations followed.

VLI-880 (VLI-88000-NF) VESDA Laser Industrial aspirating smoke detector

Incorporating the following ancillary equipment: - VRT-Q00 Remote VLI display (with 7 relays) - VRT-T00 Remote VLI display (no relays) - VRT-500 Remote relay unit (with 7 relays)

305g/01

Notes: 1.For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2.The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3.System design, installation and commissioning shall be performed in accordance with the VESDA VLI product guide (18500). 4.Remote display, programmer and relay modules are also approved in a 19 sub rack. 5.The detector is also approved when used with in-line filter models, E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. VLI-88000-NF is the alternative model number intended for French market. 7.When installing pipework systems containing in-line components, guidance from the 18336 Open-flow In-Line Components" document shall be sought and the recommendations followed.

VLI-885 (VLI-88500-NF) VESDA Laser Industrial aspirating smoke detector with VESDAnet card

Incorporating the following ancillary equipment: - VRT-Q00 Remote VLI display (with 7 relays) - VRT-T00 Remote VLI display (no relays) - VRT-500 Remote relay unit (with 7 relays)

305g/02

Notes: 1.For compliance with clause 5.10 of EN 54-20 the detector shall be supplied with power from a power supply conforming to the requirements of EN 54-4. 2.The device is approved for sensitivity Classes A, B and C. The Class of any pipe/hole configuration and detector sensitivity must be determined using ASPIRE2. 3.System design, installation and commissioning shall be performed in accordance with the VESDA VLI product guide (18500). 4.Remote display, programmer and relay modules are also approved in a 19 sub rack. 5.The detector is also approved when used with in-line filter models,

Page 311: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.1COMMERCIAL DETECTORS

31 Dec 2012 301

Certificated Products LPCB Ref. No.

E700-FILASSY and VSP-850 in accordance with the appropriate VESDA application guide (10856 or 17785). 6. VLI-88500-NF alternative model number intended for French market. 7 .When installing pipework systems containing in-line components, guidance from the 18336 Open-flow In-Line Components" document shall be sought and the recommendations followed.

Accessories:

E700-FILASSY In line filterVSP-850 In line filter

Zeta Alarm Systems by GLT Exports LimitedDetection House, 72-78 Morfa Road, Swansea SA1 2EN, United KingdomTel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176E-mail: [email protected] • Website: www.gltexports.com

Certificate No: 010v to EN 54-7: 2000 + A1: 2002 + A2: 2006

Point Smoke DetectorsCertificated Products LPCB Ref.

No.80-020 Fyreye FEO2000 Conventional optical smoke detector (80-50, 80-052, 80-054 mounting bases) 010v/0180-120 Fyreye FEAO2000 Analogue addressable optical smoke detector (80-50, 80-080, 80-090 mounting bases) 010v/02

Bases:80-050 FE CB Common mounting base80-052 FE DB Diode mounting base80-054 FE RB Relay mounting base80-080 FEA RB Addressable relay mounting base80-090 FE IB Negative switching isolating base

Certificate No: 010u to EN 54-5: 2000 + A1: 2002

Point Heat DetectorsCertificated Products LPCB Ref.

No.80-030 Fyreye FEHR2000 Conventional Class A1R heat detector (80-50, 80-052, 80-054 mounting bases) 010u/0180-032 Fyreye FEHBR2000

Conventional Class BR heat detector (80-050,80-052,80-054 mounting bases) 010u/02

80-040 Fyreye FEFH2000 Conventional Class C heat detector (80-50, 80-052, 80-054 mounting bases) 010u/0380-130 Fryeye FEAH2000 Analogue addressable Class A2S heat detector (80-50, 80-080, 80-090 mounting bases) 010u/0480-131 Fyreye FEAHH2000

Analogue addressable Class CS heat detector (80-50, 80-080, 80-090 mounting bases) 010u/05

Bases:80-050 FE CB Common mounting base80-052 FE DB Diode mounting base80-054 FE RB Relay mounting base80-080 FEA RB Addressable relay mounting base80-090 FE IB Negative switching isolating base

Page 312: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.2DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

302 31 Dec 2012

Statistics show that Government initiatives, which have increased the amount of self-contained smoke alarms fitted in domestic dwellings, have had a significant impact in reducing the amount of deaths and injuries caused by fire in the UK.

In Section 1: Fire detection and fire alarm systems of the Building Regulations 2010, Document B1 Fire Safety in Dwellings it states that “All new dwelling houses shall be provided with a fire detection and fire alarm system in accordance with the relevant recommendations of BS 5839-6: 2004 to at least a Grade D, Category LD3 standard”

BS 5839-6: 2004 Grade D requires a system of one or more mains-powered smoke alarms each with an integral standby supply (i.e. battery back-up). The system may in addition incorporate one or more mains powered heat alarms, each with an integral standby supply.

LPCB’s list of approved products in this section is intended to help you select equipment that complies with these regulatory requirements. The initial approval and continued approval processes of these types of detectors are outlined in scheme document SD078.

Products listed in this section have been approved to: BS 5446-1: 2000 Fire detection and fire alarm devices for dwellings Part 1 Specification for smoke

alarms BS 5446-2: 2003 Fire detection and fire alarm devices for dwellings Part 2 Specification for heat

alarms BS 5446-3: 2005 Specification for smoke alarm kits for deaf and hard of hearing people EN 14604: 2005 Smoke alarm devices EN 50291: 2001 Electrical apparatus for the detection of Carbon monoxide in domestic premises -

Test method and performance requirements EN 50291-1: 2010 Electrical apparatus for the detection of Carbon monoxide in domestic premises -

Test method and performance requirements EN 50291-2: 2010 Electrical apparatus for the detection of Carbon monoxide in domestic premises -

Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft-Additional test method and performance requirements.

LPS1282: Issue 1 Requirements and testing procedures for combined domestic smoke and carbon monoxide detectors.

For domestic applications, care needs to be taken over the correct choice of the type of detector, its siting and the condition of batteries in order to maintain the alarm in accordance with the manufacturer’s requirements.

Further guidance is available from LPCB if required.

Audit:Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard.

Note:1. EN 14604: 2005 supersedes BS 5446-1: 2000 which was withdrawn in July 2008. Information concerning

the date of withdrawal of conflicting standards in the foreword to EN 14604: 2005 is incorrect. The correct data is given in the Foreword to the UK version of BS EN 14604: 2005 and gives the date of withdrawal of BS 5446:1: 2000 as July 2008. However, EN 14604: 2005 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 August 2008. It is therefore recommended that detectors are certificated to EN 14604: 2005 as soon as possible.

2. EN 50291-1: 2010 supersedes EN 50291: 2001. Information concerning the date of withdrawal of conflicting national standard is 15th April 2013 as stated in the forward of EN 50291-1: 2010.

Page 313: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.2DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

31 Dec 2012 303

Digital Security Controls, a Division of Tyco Safety Products Canada Ltd3301 Langstaff Road, Concord, ON L4K 4L2, CanadaTel: (001) 905 760 3000 • Fax: (001) 905 760 3020E-mail: [email protected] • Website: www.dsc.com

Certificate No: 1018a to EN 50291: 2001

Certificated Products LPCB Ref. No.

WS4913 Type B battery operated carbon monoxide alarm with integral 433.92MHz RF transmitter. 1018a/01

Notes: 1) The functionality of the RF link is excluded from the scope of the certification.

WS8913 Type B battery operated carbon monoxide alarm with Integral 868.35MHz RF transmitter. 1018a/02Notes: 1) The functionality of the RF link is excluded from the scope of the certification.

Eyston Company Ltd27 Zhen Tian South Road, Wei Xing Industrial Zone, Yan Tian, Feng Gang, Dongguan, Guangdong, ChinaTel: +852 25573135 • Fax: +852 28970249E-mail: [email protected] • Website: www.eyston.com

Certificate No: 679b to EN 14604: 2005

Smoke AlarmCertificated Products LPCB Ref.

No.SD-176H Battery operated ionisation smoke alarm with alarm silence feature 679b/01SD-170H Battery operated ionisation smoke alarm 679b/02SD-1982 9V Battery operated photoelectric smoke alarm with alarm silence feature 679b/03SD-1782 9V Battery operated ionisation smoke alarm with alarm silence feature 679b/04SD-196H Battery operated photoelectric smoke alarm with alarm silence feature 679b/05

Fireblitz Extinguisher LtdUnits 15/17 Manford Industrial Estate, Manor Road, Erith, Kent DA8 2AJ, United KingdomTel: +44 (0)1322 342238 • Fax: +44 (0)1322 331532E-mail: [email protected] • Website: www.fireblitz.co.uk

Certificate No: 971a-(cl-2) to EN 14604: 2005

Smoke AlarmsCertificated Products LPCB Ref.

No.FireHawk FHB10 10 year batteryphotoelectric smoke alarm 971a/01FireHawk FHB10i 10 year batteryphotoelectric smoke alarm with interlink 971a/02FireHawk FH250BB Mains powered operated photoelectric smoke alarm with primary back-up battery 971a/03FireHawk FH250RB Mains powered operated photoelectric smoke alarm with rechargeable lithium back-up

battery971a/04

FireHawk FH250LB Mains powered operated photoelectric smoke alarm with longlife lithium back-up battery 971a/05

Page 314: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.2DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

304 31 Dec 2012

Firesafe10 Sanderson's Way, Marton, Blackpool FY4 4NB, United KingdomTel: 01253 699500 • Fax: 01253 699550E-mail: [email protected] • Website: www.firesafe.co.uk

Certificate No: 971a-(cl-5) to EN14604: 2005

Smoke AlarmsCertificated Products LPCB Ref.

No.FRAOMB Mains powered operated photoelectric smoke alarm with primary back-up battery 971a/09FRAOMBL Mains powered operated photoelectric smoke alarm with rechargeable lithium back-up

battery971a/10

Gira Giersiepen Gmbh & Co. KGDahlienstrasse, D-42461 Radevormwald, GermanyTel: +49 (2195) 602-0 • Fax: +49 (2195) 602-339E-mail: [email protected] • Website: www.gira.de

Certificate No: 1025a-(cl-1) to EN 14604: 2005

Smoke AlarmsCertificated Products LPCB Ref.

No.2330 02 Battery operated photoelectric smoke alarm (replaceable battery) 1025a/01

Note: 1. The radio link functionality is not included within the scope of approval

2334 02 Mains operated photoelectric smoke alarm 1025a/02Note: 1. The radio link functionality is not included within the scope of approval

Jalo Helsinki Oy / Jalo LtdBetonimiehenkuja 3, Otaniemi, Espoo, FinlandTel: +358 40 5639280E-mail: [email protected] • Website: www.jalohelsinki.fi

Certificate No: 1050a-(cl-1) to EN 14604: 2005

Certificated Products LPCB Ref. No.

Kupu J1-A 9v battery operated photoelectric smoke alarm with alarm silence feature 1050a/01Notes:

1. Cover is mesh / fabric outer shell2. Colour Variants of the Cover:

004 - Fabric Green006 - Fabric Pink008 - Fabric Brown009 - Fabric Grey010 - Fabric Graphite White

Lento J2-A 9v battery operated photoelectric smoke alarm with alarm silence feature 1050a/03Notes:

1. Cover is hawk moth shaped outer shell2. Colour Variants of the Cover:

002 - Original Black003 - Original White004 - Original Grey

Page 315: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.2DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

31 Dec 2012 305

Certificated Products LPCB Ref. No.

006 - Original Pink012 - Stripe Green013 - Stripe Red

John Lewis PartnershipC/o Sprue Safety Products Ltd, Vanguard Centre, Sir Williams Lyons Road, Coventry CV4 7EZ, United KingdomTel: +44 (0) 2476 323232 • Fax: +44 (0) 2476 693610

Certificate No: 651e to EN 14604: 2005 and LPS 1282 Issue 1.0

Combined Smoke and Carbon Monoxide alarmsCertificated Products LPCB Ref.

No.SCO5-JL Combination carbon monoxide and photoelectric smoke alarm 651e/01

Kidde Finland OyTiilenpolttajankuja 6, 01720 Vantaa, FinlandTel: +358 9 615 87 235 • Fax: +358 9 615 87 285E-mail: [email protected] • Website: www.kidde.fi

Certificate No: 904a-(cl-2) to EN 14604:2005

Smoke AlarmCertificated Products LPCB Ref.

No.0914N Replaceable 9V Battery operated ionization smoke alarm 904a/020915N Replaceable 9V Battery operated ionization smoke alarm 904a/030916N Replaceable 9V Battery operated ionization smoke alarm

with alarm silence feature904a/04

0918N Replaceable 9V Battery operated ionization smoke alarmwith alarm silence feature

904a/05

Kidde Safety Europe LtdMathison Way, Poyle Road, Colnbrook, Berkshire SL3 0HB, United KingdomTel: 01753 685148 • Fax: 01753 685096E-mail: [email protected] • Website: www.kiddesafetyeurope.co.uk

Certificate No: 904a-(cl-1) to EN 14604: 2005

Domestic AlarmsCertificated Products LPCB Ref.

No.0910UK 9V Battery operated ionization smoke alarm 904a/010914UK Replaceable 9V Battery operated ionization smoke alarm 904a/020914UK (Fire Sentry) Replaceable 9V Battery operated ionization smoke alarm 904a/020915UK Replaceable 9V Battery operated ionization smoke alarm 904a/030916UK Replaceable 9V Battery operation ionization smoke alarm with alarm silence feature 904a/040918UK Replaceable 9V Battery operated ionization smoke alarm with emergency light and alarm

silence feature904a/05

i9040EU Replaceable 9V Battery operated ionization smoke alarm with alarm silence feature 904a/06i9060EU Replaceable 9V Battery operated ionization smoke alarm with alarm silence feature 904a/07i9080EU Replaceable 9V Battery operated ionization smoke alarm with emergency light and alarm 904a/08

Page 316: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.2DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

306 31 Dec 2012

Certificated Products LPCB Ref. No.

silence feature

Ningbo Siterwell Electronics Co., Ltd.76 Haichuan Road, Chuangye Zone B, Jiangbei, Ningbo, Zhejiang Province 315032, ChinaTel: 0086-574-8307 6161 • Fax: 0086-574-8307 6652E-mail: [email protected] • Website: www.china-siter.com

Certificate No: 1044a to EN 14604: 2005

Certificated Products LPCB Ref. No.

GS505 Battery operated photoelectric smoke alarm (replaceable battery) 1044a/01GS506 Battery operated photoelectric smoke alarm (replaceable battery) 1044a/02GS503 Battery operated photoelectric smoke alarm (replaceable battery) 1044a/03

Sabre Fire & Security Ltd6 South Mundells, Welwyn Garden City, Herts AL7 1EP, United KingdomTel: 01707 393888E-mail: [email protected]

Certificate No: 971a-(cl-4) to EN14604: 2005

Certificated Products LPCB Ref. No.

4WOB Mains powered operated photoelectric smoke alarm with primary back-up battery 971a/064WOR Mains powered operated photoelectric smoke alarm with rechargeable lithium back-up

battery971a/07

Shanghai Mosafe Equipment Co.LtdUnit 203, Block B2, 889 Shangcheng Road, Pudong New Area, Shanghai 200120, ChinaTel: +86 21 60753200

Certificate No: 1044a-(cl-1) to EN 14604: 2005

Smoke AlarmsCertificated Products LPCB Ref.

No.MS505 Battery operated photoelectric smoke alarm (replaceable battery) 1044a/01MS506 Battery operated photoelectric smoke alarm (replaceable battery) 1044a/02MS503 Battery operated photoelectric smoke alarm (replaceable battery) 1044a/03

Sprue Safety Products LtdVanguard Centre, Sir William Lyons Road, Coventry CV4 7EZ, United KingdomTel: +44 (0)2476 323232 • Fax: +44 (0)2476 693610E-mail: [email protected] • Website: www.fireangel.co.uk

Certificate No: 651c to EN 50291: 2001

Page 317: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.2DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

31 Dec 2012 307

Carbon Monoxide AlarmsCertificated Products LPCB Ref.

No.CO-828 Carbon Monoxide Alarm - LCD 651c/01CO-808 Carbon Monoxide Alarm - LED 651c/02CO-808S Sealed Carbon Monoxide Alarm - Dual LED 651c/03

Certificate No: 651d to EN 14604: 2005

Smoke AlarmsCertificated Products LPCB Ref.

No.SI-601-XX FireAngel Battery operated ionisation smoke alarm 651d/01SI-610-XX FireAngel Sealed Battery operated ionisation smoke alarm 651d/02WSI-601XX FireAngel Battery operated ionisation smoke alarm with RF transmitter module 651d/03

Note: The RF transmitter module is not covered within the scope of this approvalSO-601-XX FireAngel Battery operated optical smoke alarm 651d/04SO-610-XX FireAngel Sealed Battery operated optical smoke alarm 651d/05WSO-601-XX FireAngel Battery operated optical smoke alarm with RF transmitter module 651d/06

Note: The RF transmitter module is not covered within the scope of this approval.WSO-610-XX FireAngel Sealed Battery operated optical smoke alarm with RF transmitter module 651d/09

Note: The RF transmitter module is not covered within the scope of this approval

Note:

-XX, denotes Country and Language variants

Suffix DescriptionBlank UK variant-DE Germany variant-FR France variant-NO Norway variant-NL Netherlands variant-FI Finland variant-ES Spain variant-BE Belgium variant-SE Sweden variant-AT Austria variant-IT Italy variant-DK Denmark variant-EU Generic European variant-BNL Dual-language variant for Belgium and the Netherlands (Dutch and French language)

Certificate No: 651e to EN 14604: 2005 and LPS 1282 Issue 1.0

Combined Smoke and Carbon Monoxide AlarmsCertificated Products LPCB Ref.

No.SCO5-XX Fire Angel Combination carbon monoxide and photoelectric smoke alarm. 651e/01SCO5-XX First Alert Combination carbon monoxide and photoelectric smoke alarm. 651e/01

Notes:1) -XX, denotes Country and Language variants.

Suffix Description-UK UK variant-DE Germany variant-FR France variant-NO Norway variant-NL Netherlands variant-FI Finland variant-ES Spain variant-BE Belgium variant-SE Sweden variant-AT Austria variant-IT Italy variant-DK Denmark variant-EU Generic European variant

Page 318: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 4.2DOMESTIC ALARMS - SMOKE, HEAT AND CARBON MONOXIDE

308 31 Dec 2012

-CE Dual-language variant for Belgium and the Netherlands (Dutch and French language)-Q UK Retail-JL John Lewis

2) Tested to latest EMC standard EN 50270:2006

Visonic24 Habarzel Street, Tel Aviv 69710, IsraelTel: +44 (0)870 7300810 • Fax: +44 (0)870 7300801E-mail: [email protected] • Website: www.visonic.com

Certificate No: 512e to EN 50291: 2001

Carbon Monoxide AlarmsCertificated Products LPCB Ref.

No.MCT-442 Type A battery operated carbon monoxide alarm 512e/01

Weckx HandelsondernemingStalbergweg 55, 5913 BJ Venlo, The NetherlandsTel: +31 (0)77 3512776 • Fax: +31 (0)77 3547959E-mail: [email protected] • Website: http://www.weckx.nl

Certificate No: 971a-(cl-3) to EN 14604: 2005

Certificated Products LPCB Ref. No.

W-Save WS10 10 year battery operated photoelectric smoke alarm 971a/01W-Save WS10i 10 year battery operated photoelectric smoke alarm with interlink 971a/02

Zeta Alarm Systems by GLT Exports LimitedDetection House, 72-78 Morfa Road, Swansea SA1 2EN, United KingdomTel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176E-mail: [email protected] • Website: www.gltexports.com

Certificate No: 330j to EN 14604: 2005

Certificated Products LPCB Ref. No.

ZD-SI-601 Battery operated ionisation smoke alarm 330j/01ZD-SI-610 Battery operated ionisation smoke alarm 330j/02ZD-SO-601 Battery operated optical smoke alarm 330j/03ZD-SO-610 Battery operated optical smoke alarm 330j/04

Page 319: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 309

The purpose of a manual call point is to enable a person discovering a fire to initiate the operation of a fire alarm system so that appropriate measures can be taken. Therefore it is important for the manual call point to be recognizable and simple to use. For this reason, the European standard has attempted to standardise their appearance and function.

There are basically two types of manual call points which are related to the method of operation.- Type A: direct operation (single action).- Type B: indirect operation (double action).

Both types require the breaking or the visible displacement by change of position of a frangible element forming part of the front face.

Guidance on the selection, siting and speed of response should be sought from the applicable installation rule or code of practice (e.g. BS 5839-1). For example BS 5839-1 recommends only type A with a speed of evacuation signal within 3 seconds. Other codes of practice, may require a type B installation.

This section lists manual call points approved for use in fire detection and fire alarm systems in buildings. The initial approval and continued approval processes for manual call points are outlined in scheme document SD041.

Products listed in this section have been approved to:

EN 54-11: 2001 Manual call points EN 54-11: 2001 + A1: 2005 Manual call points EN 54-25: 2008 Components using radio links ISO 7240-11: 2005 Manual call points

Audit:Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard.

Notes:1. EN 54-11: 2001 supersedes BS 5839-2: 1983 which was withdrawn in November 2003. EN 54-11: 2001 is

now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market from 1 September 2008.

2. EN 54-25: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 March 2011. It is therefore recommended that radio link components are certificated to EN 54- 25: 2008

3. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

Advanced Electronics Limited34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United KingdomTel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222E-mail: [email protected] • Website: www.Advel.co.uk

Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005Certificate No: 928h-(cl-5) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928p-(cl-1) to EN 54-11: 2001 + A1: 2005 and EN 54-25: 2008

Page 320: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

310 31 Dec 2012

Certificated Products LPCB Ref. No.

58100-908 ADV Analogue addressable manual call point with short circuit isolator and surface mounting box.

010w/03

20-VCP100-ADV Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

20-SGCP100-ADV Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note:1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

AncillariesSR01 Surface mounting boxFlush mounting plate

Advantronic Systems S.L.C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, SpainTel: +34 91 806 2343 • Fax: +34 91 803 1171E-mail: [email protected] • Website: www.advantronic.es

Certificate No: 928h-(cl-3) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928p-(cl-2) to EN 54-11: 2001 + A1: 2005 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

AV111AL Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

AVW111AL Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note: 1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

AncillariesSR01 Surface mounting boxFlush mounting plate

AMPAC Technologies PTY Ltd7 Ledgar Road, Balcatta 6021, AustraliaTel: +618 (9242) 3333 • Fax: +618 (9242) 3334E-mail: [email protected] • Website: www.ampac.net

Certificate No: 010n to EN 54-11:2001Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005Certificate No: 010n-(cl-2) to EN54-11: 2001 + A1: 2005Certificate No: 010w-(cl-2) to EN54-11: 2001 + A1: 2005 & EN54-17: 2005

Manual Call pointsCertificated Products LPCB Ref.

No.213-0050 Analogue addressable manual call point with surface mounting box 010n/02213-0052 Analogue addressable manual call point with surface mounting box 010n/06213-0051 Analogue addressable manual call point with short circuit isolator and surface mounting

box010w/01

213-0053 Analogue addressable manual call point with short circuit isolator and surface mounting box

010w/03

58100-950AMP Discovery analogue addressable waterproof manual call point 010n/0858100-951AMP Discovery analogue addressable waterproof manual call point with short circuit isolator 010w/06

Page 321: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 311

Apollo Fire Detectors Limited36 Brookside Road, Havant, Hampshire PO9 1JR, United KingdomTel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754E-mail: [email protected]

Sales Enquiries Germany,Apollo Deutschland GmbHTel: +49 5241 330 60 • Fax: +49 5241 330 629E-mail: [email protected]

Sales Enquiries Spain,Apollo EspanaTel: +34 627 988 061 • Fax: +34 949 335 289E-mail: [email protected]

Sales Enquiries, ChinaApollo Fire Detectors Limited, Shanghai representative officeTel: +86 21 5237 0922 • Fax: +86 21 5237 0920E-mail: [email protected]

Certificate No: 010d to BS 5839: Part 2:1983Certificate No: 010n to EN 54-11: 2001Certificate No: 010w to EN 54-11: 2001 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

55000-900 XP95 Analogue addressable flush and surface mounted manual call point 010d/06Certificated with Apollo, Series 90 and XP95 communication protocols

55000-940 XP95 IS Analogue addressable intrinsically safe manual call point 010d/03Certificated with Apollo, Series 90 and XP95 communication protocols

55000-950 XP95 Analogue addressable waterproof manual call point 010d/04Certificated with Apollo, Series 90 and XP95 communication protocols

58000-900 Discovery Analogue addressable flush and surface mounted manual call point 010d/05Certificated with Series 90, XP95 and Discovery digital communication protocols

58000-910 Discovery Analogue addressable flush mounted manual call point 010d/05Certificated with Series 90, XP95 and Discovery digital communication protocols

58000-920 Discovery Analogue addressable surface mounted manual call point 010d/05Certificated with Series 90, XP95 and Discovery digital communication protocols

59000-910 XPlorer Analogue addressable surface mounted manual call point 010n/01Certificated with Series 90 and XP95 digital communication protocolsCertificated with the Burgess V3NCSET7 Mk 1 microswitch

55100-905 XP95 Analogue addressable manual call point with surface mounting box 010n/0258100-910 Discovery Analogue addressable manual call point with surface mounting box 010n/0655100-908 XP95 Analogue addressable manual call point with short circuit isolator and surface mounting

box010w/01

58100-908 Discovery Analogue addressable manual call point with short circuit isolator and surface mounting box

010w/03

58100-905 Discovery Analogue addressable manual call point with short circuit isolator, glass frangible element and surface mounting box

010w/05

58100-950 Discovery Analogue addressable waterproof manual call point 010n/0855100-940 XP95IS Analogue addressable intrinsically safe manual call point. 010n/0958100-951 Discovery Analogue addressable waterproof manual call point with short circuit isolator 010w/06

Page 322: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

312 31 Dec 2012

Argus Security S.r.l.Via del Canneto 14, Valle delle Noghere, 34015 Muggia, Trieste, ItalyTel: +39 (0) 402821110 • Fax: +39 (0) 402823483E-mail: [email protected] • Website: www.argussecurity.it

Certificate No: 928h to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005Certificate No: 928p to EN 54-11: 2001 + A1: 2005 and EN 54-25: 2008

Manual Call PointsCertificated Products LPCB Ref.

No.VCP100 Analogue addressable Type A re-settable manual call point with short circuit isolator

(SR01 and Flush mounting plate)928h/01

SGCP100 Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note:1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

SGCP100-FR Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note:1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

AncillariesSR01 Surface mounting boxFlush mounting plate

Argus-Spectrum65 Serdobolskaya St, St. Petersburg 197342, Russian FederationTel: +7 812 7037500 • Fax: +7 812 7037501E-mail: [email protected] • Website: www.argus-spectr.ru

Certificate No: 928h-(cl-2) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928p-(cl-3) to EN 54-11: 2001 + A1: 2005 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

VCP100 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

SGCP100 Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note:1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

AncillariesSR01 Surface mounting boxFlush mounting plate

Page 323: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 313

ATEIS Middle East FZCOLIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab EmiratesTel: +971 4 3262730 • Fax: +971 4 3262731E-mail: [email protected] • Website: www.ateis.ae

Certificate No: 928h-(cl-10) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005Certificate No: 928p-(cl-4) to EN 54-11: 2001 + A1: 2005 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

VELOX VCP100 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

VELOX WLCP100 Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note:1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

AncillariesSR01 Surface mounting boxFlush mounting plate

Bentel Security s.r.l.Via Gabbiano, n.22, Z.Ind. Le S.Scolastica, Corropoli, Teramo 64013, ItalyTel: +39 0861 839060 • Fax: +39 0861 839065E-mail: [email protected] • Website: www.bentelsecurity.com

Certificate No: 681n to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

FC420CP Addressable Type A indoor manual call point 681n/01FC421CP Addressable Type A outdoor manual call point 681n/02

Bristol Fire LtdThe Colin Saunders Innovation Centre, Mewburn Road, Banbury, Oxfordshire OX16 9PA, United KingdomTel: +44 1295 817623E-mail: [email protected] • Website: www.bristol-fire.com

Certificate No: 506d-(cl-1) to EN 54-11 :2001 + A1: 2005

Certificated Products LPCB Ref. No.

BF-M-0317 Conventional indoor surface flush mounting manual call point 506d/01

Accessories:AHMB-0217 back box for surface mounting

Page 324: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

314 31 Dec 2012

Ceasefire Industries Ltd"Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, IndiaTel: +91 -22-22854677, 22854678 • Fax: +91-22-66349069E-mail: [email protected] • Website: www.ceasefire.in

Certificate No: 166b-(cl-1) to EN54-11: 2001 + A1: 2005Certificate No: 164j-(cl-1) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

MCP1A-R470SF-H029-02 Indoor surface/flush mounting conventional call point 166b/39HCP-E Addressable Manual Call Point

(SR and SR1T mounting boxes)164j/01

Accessories: SR Surface mounting plastic boxSR1T Surface mounting plastic box c/w 1 terminalSR2T Surface mounting plastic box c/w 2 terminals SR3T Surface mounting plastic box c/w 3 terminals SR4T Surface mounting plastic box c/w 4 terminals MR Surface mounting metal boxETT European Terminal Tray ETT1, 2 & 3L Earth Continuity LinkBZR/1 Bezel Type 1BZR/2 Bezel Type 2BZR/3 Bezel Type 3M141 Spacer PiecePTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TEC Hinged Cover(1)

Note:The hinged cover is optionally indicated by the presence of ‘C’ at the end of the model number.

Context Plus LtdExport House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United KingdomTel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817E-mail: [email protected] • Website: www.xportsales.com

Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005

Certificated Products LPCB Ref. No.

55100-908 IMC Analogue addressable manual call point with short circuit isolator and surface mounting box.

010w/01

Cooper Fulleon LimitedLlantarnam Park, Cwmbran, South Wales NP44 3AW, United KingdomTel: +44 (0)1633 628500 • Fax: +44 (0)1633 866346E-mail: [email protected] • Website: www.cooperfulleon.com

Certificate No: 378c to EN 54: Part 11: 2001

Certificated Products LPCB Ref. No.

CX/G/R/BB Conventional re-settable indoor manual call point, with surface mount back box* 378c/01CX/P/R/NB Conventional indoor manual call point, flush mounted* 378c/02CX/P/R/BB Conventional indoor manual call point, with surface mount back box* 378c/02CXL/GP/R/BB Conventional type A glass or plastic re-settable indoor manual call point, with surface 378c/03

Page 325: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 315

Certificated Products LPCB Ref. No.

mount back boxCXL/GP/R/NB Conventional type A glass or plastic re-settable indoor manual call point, flush mounted 378c/03CXL/GP/R/WP Conventional type A glass or plastic re-settable indoor/outdoor manual call point 378c/04CXL/GP/R/BB Conventional type A glass or plastic re-settable indoor manual call point, with surface

mount back box378c/05

CXL/GP/R/NB Conventional type A glass or plastic re-settable indoor manual call point, flush mounted 378c/05CXL/GP/R/WP Conventional type A glass or plastic re-settable indoor/outdoor manual call point 378c/06CXL/GP/R/BB/HE Conventional Type A glass or plastic re-settable indoor manual call point with Chinese

text378c/07

CXL/GP/R/WP/HE Conventional Type A glass or plastic re-settable indoor / outdoor manual call point with Chinese text

378c/08

* Approved with V4NCSET7 Mk1 or V4NSET7-UL micro switches only.

Accessories:/BB surface mounted (plastic back box)

Cooper Industries IncWheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United KingdomTel: +44 (0)1302 303303 • Fax: +44 (0)1302 367155E-mail: [email protected] • Website: www.cooper-ls.com

Certificate No: 378d-(cl-1) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005Certificate No: 378d-(cl-2) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

CBG 370S Addressable type A glass indoor manual call point, with surface mount back box 378d/05CBG 370 Addressable type A glass indoor manual call point, flush mounted 378d/06PAJ3034900 Addressable type A plastic re-settable indoor manual call point with surface mount back

box378d/07

CBG 370WP Addressable weatherproof type A glass indoor/outdoor manual call point 378d/08PAJ3035100 Addressable weatherproof type A plastic re-settable indoor/outdoor manual call point 378d/09CBG 370S-O Addressable type A glass indoor manual call point, with surface mount back box 378d/12CBG 370-O Addressable type A glass indoor manual call point, flush mounted 378d/13CBG 370WP-O Addressable weatherproof type A glass indoor/outdoor manual call point 378d/14FXN501 Addressable type A glass indoor manual call point, with surface mount back box 378d/05FXN503 Addressable weatherproof type A glass indoor/outdoor manual call point 378d/08MBG813 Addressable type A glass indoor manual call point, with surface mount back box 378d/05MBG814 Addressable type A glass indoor manual call point, flush mounted 378d/06MBG817 Addressable weatherproof type A glass indoor/outdoor manual call point 378d/08FXN502 Addressable type A glass indoor manual call point, flush mounted 378d/06

Cooper Lighting and Safety LtdWheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United KingdomTel: 01302 303397 • Fax: 01302 303251Website: www.cooper-Is.com

Certificate No: 714k to EN54-11: 2001 + A1: 2005

Manual Call PointsCertificated Products LPCB Ref.

No.MBG914 Conventional type A indoor manual call point with 470R resistor and 4V7 zener diode 714k/01CX201 Conventional type A indoor manual call point with 680R resistor 714k/01FX201 Conventional type A indoor manual call point with 680R resistor 714k/01MBG917 Conventional type A weatherproof manual call point with 470R resistor and 4V7 zener

diode714k/02

CX203 Conventional type A weatherproof manual call point with 680R 2W resistor 714k/02FX203 Conventional type A weatherproof manual call point with 680R 2W resistor 714k/02MBG914 Conventional type A indoor manual call point with 470R resistor and 4V7 zener diode 714k/03

Page 326: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

316 31 Dec 2012

Certificated Products LPCB Ref. No.

CX201 Conventional type A indoor manual call point with 680R resistor 714k/03FX201 Conventional type A indoor manual call point with 680R resistor 714k/03MBG917 Conventional type A weatherproof manual call point with 470R resistor and 4V7 zener

diode714k/04

CX203 Conventional type A weatherproof manual call point with 680R 2W resistor 714k/04FX203 Conventional type A weatherproof manual call point with 680R 2W resistor 714k/04

EMCO125 El Alamean Street, El Mohandessin, Cairo, EgyptTel: 00202 33 44 3 245 • Fax: 00202 330 36 86 0E-mail: [email protected] • Website: www.4emco.com

Certificate No: 928h to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

ACP200 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

AncillariesSR01 Surface mounting boxFlush mounting plate

Emergi-Lite Safety Systems (Thomas & Betts Ltd)Bruntcliffe Lane, Morley, Leeds LS27 9LL, United KingdomTel: +44 (0)113 2810600 • Fax: +44 (0)113 2810601Website: www.emergi-lite.co.uk

Certificate No: 010n to EN 54-11:2001Certificate No: 010w to EN 54-11:2001 and EN 54-17:2005

Certificated Products LPCB Ref. No.

FA95-400 Analogue addressable manual call point with surface mounting box 010n/02FADY-400-ISO Analogue addressable manual call point with short circuit isolator and surface mounting

box010w/03

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)P.O.Box 22436, Industrial Area 13, Sharjah, United Arab EmiratesTel: +971 6 5340300 • Fax: +971 6 5340090E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 506d to EN 54-11: 2001

Certificated Products LPCB Ref. No.

FX-0217 Conventional indoor surface/flush mounting manual call point 506d/01Note: Approved for surface mount use when used with the AHMB-0217 back box

Accessories:AHMB-0217 back box for surface mounting

Page 327: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 317

Eurotech Fire Systems Ltd19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United KingdomTel: (0)203 141 0999E-mail: [email protected] • Website: www.eurotechfire.com

Certificate No: 653a-(cl-2) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

EURVC-MCP Conventional Type A re-settable indoor flush/surface manual call point. 653a/01Notes:1. Flush mount approved model EURVC-MCP-IP24F (M200)2. Surface mount approved model EURVC-MCP-IP24 (M200 + M125)3. Surface mount approved model EURVC-MCP-IP24S (M223)4. Approved colour, red only

Accessories

M200 wall plateM125 back boxM223 back box

Everday Technology Co. LimitedNo,.95., Sec. 2., Ligong 1 St. Road., Letzer Industrial Park, Yilan County 26841, Taiwan ROCTel: +886 3 990 6099 • Fax: +862 3 990 6029E-mail: [email protected] • Website: www.everday.com

Certificate No: 512f to EN 54-11: 2001 + A1: 2005

Manual Call PointsCertificated Products LPCB Ref.

No.EM921 Conventional manual call point with LED 512f/01EM921-F Conventional manual call point with flashy LED 512f/02EM921-TC Convetnional manual call point with LED and transparent cover 512f/03EM921-FTC Conventional manual call point with flashy LED and transparent cover 512f/04

Accessories:EM921B1 Regular mounting base, 28mmEM921B2 High mounting base, 40mmEM921B3 High mounting base, 55m

Fike Safety Technology LtdUnit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United KingdomTel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk

Certificate No: 331e to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005Certificate No: 331d to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

403-0006 Sita analogue addressable Type A indoor manual call point with short circuit isolator 331e/01403-0007 Sita analogue addressable Type A outdoor manual call point with short circuit isolator 331e/02400-0006 Zeon conventional Type A indoor manual call point 331d/01400-0007 Zeon conventional Type A outdoor manual call point 331d/02402-0006 Twinflex conventional Type A indoor manual call point 331d/03402-0007 Twinflex conventional Type A outdoor manual call point 331d/04

Page 328: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

318 31 Dec 2012

Accessoriesfor indoor devices45-0079-205 Standard backbox25-0078-205 Bezel

Finder Elektronik A.S.Liman Mah., 6. Sok., No: 10 07070, Konyaalti, Antalya, TurkeyTel: +9 0242 344 2500 • Fax: +9 0242 344 2120E-mail: [email protected] • Website: www.finder.com.tr

Certificate No: 928h-(cl-1) to EN 54-11: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

FF VB200 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

AncillariesSR01 Surface mounting boxFlush mounting plate

Fireguard Safety Equipment Co Ltd2nd Floor, 145-147 St John Street, London EC1V 4PY, United KingdomTel: +44 (0)8450 751042 • Fax: +44 (0)845 2991039E-mail: [email protected] • Website: www.fireguard-uk.com

Certificate No: 512f-(cl-1) to EN 54-11: 2001 + A1: 2005Certificate No: 928h-(cl-8) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

Fireguard FG921-FTC Conventional manual call point with flashy LED and transparent cover 512f/04FGCP100 Analogue addressable Type A resettable indoor manual call point with short circuit

isolator (SR01 and Flush mounting plate)928h/01

Accessories:Fireguard FG921B1 Regular mounting base, 28mmFireguard FG921B2 High mounting base, 40mmFireguard FG921B3 High mounting base, 55m

Ancillaries:SR01 Surface mounting boxFlush mounting plate

Fireonica Co. Ltd2 The Dingle, Wolverhampton WV3 9ET, United KingdomTel: 01902 762 163 • Fax: 0845 299 1039E-mail: [email protected]

Certificate No: 928h-(cl-9) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

FOCP100 Analogue addressable Type A resettable indoor manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

Page 329: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 319

AncillariesSR01 Surface mounting boxFlush mounting plate

FIREX Protection System Technology Ltd28-38 Desborough Street, High Wycombe, Bucks, United KingdomTel: +44 (0)1494 601077 • Fax: +44 (0)1494 601011E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 548g-(cl-3) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

FX9201 Conventional manual call point 548g/01FX9201I Intelligent manual call point 548g/02

Gent By Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300E-mail: [email protected] • Website: www.gent.co.uk

Middle East Sales Enquiries:E-mail: [email protected]

Certificate No: 042aq to EN 54-11: 2001 + A1: 2005Certificate No: 166b-(cl-2) to EN 54-11: 2001 + A1: 2005

Manual Call PointsCertificated Products LPCB Ref.

No.S4-34800 Analogue addressable Type A indoor manual call point (S4-34895 surface mount back

box)042aq/01

Notes:1) Approved for use with glass non re-settable element

S4-34842 Analogue addressable Type A indoor manual call point with protective cover (S4-34895 surface mount back box)

042aq/02

Notes:1) Approved for use with glass non re-settable element

S4-34805 Analogue addressable Type A indoor manual call point(S4-34895 surface mount back box)

042aq/05

Notes: 1) Approved for use with plastic re-settable element

S4-34845 Analogue addressable Type A indoor manual call pointwith protective cover (S4-34895 surface mount back box)

042aq/06

Notes: Approved for use with plastic re-settable element

XENS-850 Indoor flush mounting conventional call point 166b/39XENS-805 Indoor surface mounting conventional call point 166b/39XENS-801 Indoor surface mounting conventional call point 166b/43XENS-829 Outdoor surface mounting conventional call point 166b/51

Accessories:S4-34895 surface mount back box

Page 330: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

320 31 Dec 2012

Global System Technology PlcLion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United KingdomTel: +44 (0)1283 225 478 • Fax: +44 (0)1283 222 039E-mail: [email protected] • Website: www.gst.uk.com

Certificate No: 548g-(cl-5) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

C-9202 Conventional manual call point 548g/01I-9202 Intelligent manual call point 548g/02DC-9204 Conventional re-settable indoor manual call point, surface and flush mounting (C-92FC) 548g/03DI-9204 Digital addressable re-settable indoor manual call point, surface and flush mounting (C-

92FC)548g/04

Accessories:C-92FC Transparent Cover

Group 4 Securicor PlcManor Royal, The Manor, Crawley, West Sussex RH10 9UN, United KingdomTel: +44 (0)20 87707000 • Fax: +44 (0)20 87722531Website: www.g4s.com

Certificate No: 548g-(cl-2) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

GS202C Conventional manual call point 548g/01GS202I Intelligent manual call point 548g/02

Gulf Security Technology Co., Ltd.No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, ChinaTel: +86 0335 8502434 • Fax: +86 0335 8502532E-mail: [email protected] • Website: www.gst.com.cn

Certificate No: 548g to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

C-9202 Conventional manual call point 548g/01I-9202 Intelligent manual call point 548g/02DC-9204 Conventional re-settable indoor manual call point, surface and flush mounting (D-92FC) 548g/03DI-9204 Digital addressable re-settable indoor manual call point, surface and flush mounting (D-

92FC)548g/04

Accessories:D-92FC Transparent cover

Page 331: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 321

HDRGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132E-mail: [email protected] • Website: www.hochikieurope.com

Certificate No: 164j to EN 54-11:2001 + A1: 2005Certificate No: 164r to EN 54-17: 2005, EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

1440270 Intelligent Analogue Addressable Manual Call Point (SR and SR1T mounting boxes) 164j/011440300 Weather Proof Intelligent Analogue Addressable Manual Call Point (SR and SR1T

mounting boxes)164j/04

1440380 Intelligent analogue addressable manual call point with short circuit isolator(SR mounting box)

164r/01

1440360 Weather Proof Intelligent analogue addressable manual call point with short circuit isolator

164r/02

Ancillaries:SR Surface mounting plastic box - indoor models onlySR1T Surface mounting plastic box c/w 1 terminal

Hochiki Europe (UK) LimitedGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132Website: www.hochikieurope.com

Certificate No: 164j to EN 54-11: 2001 + A1: 2005Certificate No: 164r to EN 54-17: 2005, EN 54-11: 2001 + A1: 2005Certificate No: 928p-(cl-6) to EN 54-11: 2001 + A1: 2005 and EN 54-25: 2008

Manual Call pointsCertificated Products LPCB Ref.

No.HCP-E (HFP) Intelligent Addressable Manual Call Point (SR and SR1T mounting boxes) 164j/01HCP-EF Intelligent Analogue Addressable Manual Call Point - French - (SR and SR1T mounting

boxes)164j/02

HCP-E(DPS) Intelligent Analogue Addressable Manual Call Point - with Dual Pole Switching - (SR and SR1T mounting boxes)

164j/03

HCP-W(HFP) Weather Proof Intelligent Analogue Addressable Manual Call Point(SR and SR1T mounting boxes)

164j/04

HCP-W(DPS) Weather Proof Intelligent Analogue Addressable Manual Call Point with Dual PoleSwitching (SR and SR1T mounting boxes)

164j/05

SCP-DPS Intelligent Analogue Addressable Type A Indoor Manual Call Point 164j/06HCP-E Intelligent Analogue Addressable Manual Call Point (SR and SRIT mounting boxes) 164j/01HCP-W Weather Proof Intelligent Analogue Addressable Manual Call Point

(SR and SRIT mounting boxes)164j/04

HCP-E(SCI) Intelligent Analogue Addressable Manual Call Point with short circuit isolator(SR mounting box)

164r/01

HCP-E(HFP)-SCI Intelligent Analogue Addressable Manual Call Point with short circuit isolator(SR mounting box)

164r/01

HCP-W(SCI) Weather proof Intelligent Analogue Addressable Manual Call point with shortcircuit isolator

164r/02

HCP-W(HFP)-SCI Weather Proof Intelligent analogue addressable manual call point with short circuit isolator

164r/02

HCP-EM Intelligent Analogue Addressable Manual Call Point (SR and SR1T mounting boxes) 164j/01HCP-WM Weather Proof Intelligent Analogue Addressable Manual Call Point (SR and SR1T

mounting boxes)164j/04

RSM-CP Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note: 1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

Page 332: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

322 31 Dec 2012

Accessories:SR Surface mounting plastic box - indoor models onlySR1T Surface mounting plastic box c/w 1 terminalSR01 Surface mount back box

Honeywell Control Systems LtdHoneywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United KingdomTel: 01344 655609 • Fax: 01344 655474Website: www.honeywellbuildingsolutions.co.uk

Certificate No: 262p-(cl-1) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

XLS-271 Digital addressable indoor manual call point, surface or flush mounted. 262p/01

AccessoriesKAC SR3T-P Surface mounted boxKAC ETTI-P Flush mounted box

Horing LIH Industrial Co LtdNo. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROCTel: +886 2 22487599 • Fax: +886 2 22407752

Certificate No: 506d to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

AH-0217 Conventional indoor surface/flush mounting manual call point 506d/01Note: Approved for surface mount use when used with the AHMB-0217 back box

AH-0817 Conventional Type A outdoor Manual Call Point 506d/02Note: Approved for surface mount use when used with the AHMB-0817 back box

Accessories:AHMB-0217 back box for surface mountingAHMB-0817 back box for surface mounting

Intelligent Safety & Security Technology Ltd.6-7 Ludgate Square,, London EC4M 7AS, United KingdomTel: +44 845 116 2945E-mail: [email protected] • Website: www.isst-uk.com

Certificate No: 512f-(cl-3) to EN54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

CC-01 Conventional manual call point with flashy LED 512f/02CC-02 Conventional manual call point with flashy LED and transparent cover 512f/04

Accessories:EM921B1 Regular mounting base, 28mmEM921B2 High mounting base, 40mmEM921B3 High mounting base, 55mm

Page 333: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 323

KAC Alarm Company LimitedKAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United KingdomTel: +44 (0)1527 406655 • Fax: +44 (0)1527 406677E-mail: [email protected] OR [email protected] • Website: www.kac.co.uk

Certificate No: 166b to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

WR2001 Indoor manual call point, flush mounted (single pole changeover). 166b/01WR2012 Indoor manual call point, flush mounted. 166b/02WR2004 Indoor manual call point, flush mounted. 166b/03WR2061 Indoor manual call point, flush mounted. 166b/04WR2072 Indoor manual call point, flush mounted. 166b/05WR2101 Indoor manual call point, flush mounted. 166b/06WR3001 Indoor manual call point, flush mounted (single pole changeover). 166b/07WR3101 Indoor manual call point, flush mounted. 166b/08WR3061 Indoor manual call point, flush mounted. 166b/09WR3072 Indoor manual call point, flush mounted. 166b/10WR3631 Indoor manual call point, flush mounted. 166b/11MCP545-1 Indoor surface mounting addressable manual call point 166b/35MCP545-2 Indoor flush mounting addressable manual call point 166b/36MCP545-3 Outdoor surface mounting addressable manual call point 166b/37MCP545-4 Outdoor surface mounting addressable manual call point 166b/38MCP1A-Rxxxxx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/39MCP1B-Rxxxxx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/40MCP2A-Rxxxxx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/41MCP2B-Rxxxxx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/42MCP3A-Rxxxxx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/43MCP4A-R000xx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/44MCP5A-RP01wwxx-yyyy-zz

Indoor surface/flush mounting addressable call point Advanced Protocol (and System Sensor 500 series protocol)

166b/45

MCP5A-RP03wwxx-yyyy-zz

Indoor surface/flush mounting addressable call point Advanced Protocol (and Honeywell 500 series protocol)

166b/47

Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol 2. ww X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals)3. x G (Glass element) x F (Flexible element)4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26396. IS indicates the intrinsically safe version.

MCP7A-RC01xx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/49MCP7B-RC01xx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/50WCP1A-RxxxSx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/51WCP1B-RxxxSx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/52WCP2A-RxxxSx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/53WCP2B-RxxxSx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/54WCP3A-RxxxSx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/55WCP4A-R000Sx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/56WCP5A-RPwwSx-yyyy-zz Outdoor surface mounting addressable waterproof call point Advanced Protocol (and

System Sensor 500 series protocol)166b/57

WCP5A-RPwwSx-yyyy-zz Outdoor surface mounting addressable waterproof call point Advanced Protocol (and Honeywell 500 series protocol)

166b/59

Notes:1. ww (Range 0-99 odd numbers only) indicates the communication software protocol2. S G (Glass element) S F (Flexible element)3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled

Page 334: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

324 31 Dec 2012

Certificated Products LPCB Ref. No.

drawing 08/2639 5. IS indicates the intrinsically safe version.

WCP7A-RC01Sx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/61WCP7B-RC01Sx-yyyy-zz Outdoor surface mounting conventional waterproof call point 166b/62MCP1A-Rxxxxx-yyyy-zz IIndoor surface/flush mounting conventional call point 166b/39MCP1B-Rxxxxx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/40MCP2A-Rxxxxx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/41MCP2B-Rxxxxx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/42

Notes:1. XXX xx indicates the series resistor value 039 xx (lowest 39 4K7 xx (highest 4.7 k2. xxx X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals3. xxxx G (Glass element) xxxx F (Flexible element)4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26396. IS indicates the intrinsically safe version.

MCP3A-Rxxxxx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/43Notes:1. XXX xx indicates the electrical configuration ( 000 xx = no resistor, C01 xx = single pole changeover connections)2. xxx X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals3. xxxx G (Glass element) xxxx F (Flexible element)4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26396. IS indicates the intrinsically safe version.

MCP4A-R000xx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/44Notes:1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals) 2. x G (Glass element) x F (Flexible element)3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26395. IS indicates the intrinsically safe version.

MCP7A-RC01xx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/49MCP7B-RC01xx-yyyy-zzIS Indoor surface/flush mounting conventional call point 166b/50

Notes: 1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals)2. x G (Glass element) x F (Flexible element)3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26395. IS indicates the intrinsically safe version.

MCP5A-RP07xx-zz Indoor surface/flush mounting addressable call point (Labor Strauss protocol)Advanced Protocol (and Labor Strauss protocol)

166b/67

Notes: 1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals)2. x G (Glass element) x F (Flexible element)3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

Page 335: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 325

Certificated Products LPCB Ref. No.

WCP5A-RP07Sx-zz Outdoor surface mounting addressable call point Advanced Protocol (and Labor Strauss protocol)

166b/68

Notes: 1. S G (Glass element) S F (Flexible element) 2. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

WCP1A-RxxxSx-yyyy-zzIS Outdoor surface mounting conventional waterproof call point 166b/51WCP1B-RxxxSx-yyyy-zzIS Outdoor surface mounting conventional waterproof call point 166b/52WCP2A-RxxxSx-yyyy-zzIS Outdoor surface mounting conventional waterproof call poin 166b/53WCP2B-RxxxSx-yyyy-zzIS Outdoor surface mounting conventional waterproof call point 166b/54

Notes:1. XXX xx indicates the series resistor value 039 xx (lowest 39 4K7 xx (highest 4.7 k2. xxxS G (Glass element) xxxS F (Flexible element)3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26395. IS indicates the intrinsically safe version.

WCP3A-RxxxSx-yyyy-zzIS Outdoor surface mounting conventional waterproof call point 166b/55Notes: 1. XXX Sx indicates the electrical configuration ( 000 Sx = no resistor, C01 Sx = single pole changeover connections)2. xxxS G (Glass element) xxxS F (Flexible element)3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26395. IS indicates the intrinsically safe version.

WCP4A-R000Sx-yyyy-zzIS Outdoor surface mounting conventional waterproof call point 166b/56Notes:1. S G (Glass element) S F (Flexible element)2. yyyy (Range A000 to Z999 or STCK for standard stocked product),indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26394. IS indicates the intrinsically safe version.

WCP7A-RC01Sx-yyyy-zzIS Outdoor surface mounting conventional waterproof call point 166b/61WCP7B-RC01Sx-yyyy-zzIS Outdoor surface mounting conventional waterproof call point 166b/62

Notes:1. S G (Glass element) S F (Flexible element)2. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label 3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/26394. IS indicates the intrinsically safe version.

MCP5A-RP01yz-K013-01IS

Indoor surface/flush mounting addressable call pointSensor 500 series protocol) for use in intrinsically safe systems

166b/65

MCP5A-RP03yz-K013-01IS

Indoor surface/flush mounting addressable call point500 series protocol)for use in intrinsically safe systems

166b/66

Notes: 1. S z (Surface mounted) F z (Flush mounted) 2. y G (Glass element) y F (Flexible element)

MCP6H-RC01xx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/69Notes:

1. RC01 X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals)

2. RC01x G (Glass element) RC01x F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product),

indicates a customer account code. Only specific

Page 336: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

326 31 Dec 2012

Certificated Products LPCB Ref. No.

account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label

4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

MCP6V-RC01xx-yyyy-zz Indoor surface/flush mounting conventional call point 166b/70Notes:

1. RC01 X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals)

2. RC01x G (Glass element) RC01x F (Flexible element) 3. yyyy (Range A000 to Z999 or STCK for standard stocked product),

indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label

4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

Accessories:SR Surface mounting plastic box(1)SR1T Surface mounting plastic box c/w 1 terminal(1)SR2T Surface mounting plastic box c/w 2 terminals(1) SR3T Surface mounting plastic box c/w 3 terminals(1) SR4T Surface mounting plastic box c/w 4 terminals(1) ETT European Terminal Tray ETT1, 2 & 3(1)L Earth Continuity Link(1)M141W Spacer Piece(1)PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1)C Hinged Cover(2)

Notes: 1. The above accessories are only supplied with MCP 1-7 Series

manual call points 2. The hinged cover is only supplied with the MCP & WCP Series

manual call points optionally indicated by the presence of ‘C’ at theend of the model number.

Certificate No: 166e to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

MCP5A-RPwwxx-yyyy-zz Indoor/Outdoor surface/flush mounting addressable call point with short circuit isolator Advanced Protocol (and System Sensor 500 series protocol)

166e/01

MCP5A-RPwwxx-yyyy-zz Indoor/Outdoor surface/flush mounting addressable call point with short circuit isolator Advanced Protocol (and Honeywell 500 series protocol)

166e/02

Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol 2. ww X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals)3. x G (Glass element) x F (Flexible element)4. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label5. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

WCP5A-RPwwSx-yyyy-zz Outdoor surface mounting addressable waterproof call point with short circuit isolator Advanced Protocol (and System Sensor 500 series protocol)

166e/03

WCP5A-RPwwSx-yyyy-zz Outdoor surface mounting addressable waterproof call point with short circuit isolator Advanced Protocol (and Honeywell 500 series protocol)

166e/04

Notes:1. ww (Range 0-99 even numbers only) indicates the communication software protocol2. S G (Glass element) S F (Flexible element)3. yyyy (Range A000 to Z999 or STCK for standard stocked product), indicates a customer account code. Only specific account codes are LPCB approved and indicated by the presence of the LPCB logo placed on the product label4. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

MCP5A-RP08xx-zz Indoor surface/flush mounting addressable call point with short circuit isolatorAdvanced Protocol (and Labor Strauss protocol)

166e/07

Page 337: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 327

Certificated Products LPCB Ref. No.

Notes:1. X x indicates mounting ( S =Surface mounted, F =Flush mounted, P =Pattress mounted, 1-4 = Surface mounted with 1-4 terminals)2. x G (Glass element) x F (Flexible element)3. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

WCP5A-RP08Sx-zz Outdoor surface mounting addressable call point with short circuit isolatorAdvanced Protocol (and Labor Strauss protocol)

166e/08

Notes: 1. S G (Glass element) S F (Flexible element)2. zz (Range 0-99) indicates customer marking options detailed on KAC controlled drawing 08/2639.

Accessories:SR Surface mounting plastic box(1)

SR1T Surface mounting plastic box c/w 1 terminal(1)

SR2T Surface mounting plastic box c/w 2 terminal(1)

SR3T Surface mounting plastic box c/w 3 terminal(1)

SR4T Surface mounting plastic box c/w 4 terminal(1)

ETT European Terminal Tray ETT 1, 2 & 3(1)

L Earth Continuity Link(1)

M141W Spacer Piece(1)

PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1)

C Hinged Cover(2)

Notes:1. The above accessories are only supplied with MCP Series manual call points2. The hinged cover is supplied with the MCP & WCP Series manual call points optionally indicated by the present of ‘C’ at the

end of the model number.

Labor Strauss Sicherungsanlagenbau GmbHWiegelestrasse 36, A-1231 Vienna, AustriaTel: +43 1 52114-44 • Fax: +43 1 52114-27E-mail: [email protected] • Website: www.lst.at

Certificate No: 928h-(cl-6) to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

FI700/MCP Analogue addressable Type A re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

AncillariesSR01 Surface mounting boxFlush mounting plate

MGC Systems Corp.25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3, CanadaTel: + 905 660 4655 • Fax: + 905 660 4113E-mail: [email protected] • Website: www.mircom.com

Certificate No: 512f to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

MCP-100 Conventional manual call point with LED and transparent cover 512f/04

Page 338: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

328 31 Dec 2012

Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.morley-ias.co.uk

Certificate No: 166e to EN 54-11: 2001 and EN 54-17: 2005Certificate No: 166b to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

MI-MCP-xxxxx-I Indoor surface/flush mounting addressable call point with short circuit isolator.Advanced Protocol Honeywell 500 series protocol)

166e/02

Note: 1. xxxxx = GLASS (Glass element) or FLEX_ (Flexible element)

MI-MCP-xxxxx Indoor surface/flush mounting addressable call point Advanced Protocol (and Honeywell 500 series protocol)

166b/47

Notes: 1. xxxxx = GLASS (Glass element) FLEX _ (Flexible element)

MI-WCP-R/Sx Outdoor surface mounting addressable waterproof call point Advanced Protocol (and Honeywell 500 series protocol)

166b/59

Notes: 1. Sx = S G (Glass element) S F (Flexible element)

MI-WCP-R/I/Sx Outdoor surface mounting addressable waterproof call point with short circuit isolator Advanced Protocol (and Honeywell 500 series protocol)

166e/04

Note: 1. Sx = S G (Glass element) S F (Flexible element)

Accessories:SR Surface mounting plastic box(1)

SR1T Surface mounting plastic box c/w 1 terminal(1)

SR2T Surface mounting plastic box c/w 2 terminal(1)

SR3T Surface mounting plastic box c/w 3 terminal(1)

SR4T Surface mounting plastic box c/w 4 terminal(1)

ETT European Terminal Tray ETT 1, 2 & 3(1)

L Earth Continuity Link(1)

BZR/1 Bazel Type 1(1)

BZR/2 Bazel Type 2(1)

BZR/3 Bazel Type 3(1)

M141W Spacer Piece(1)

PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1)

C Hinged Cover(2)

Notes: 1. The above accessories are only supplied with MI-MCP-xxxxx & MI-MCP-xxxxx-I manual call point 2. The hinged cover may be supplied with all models and is optionally indicated by the presence of ‘C’ at the end of the model number.

Multron Systems Pte Ltd217 Kallang Bahru, Multron Building, Singapore 339 347, SingaporeTel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869E-mail: [email protected] • Website: www.multron.com

Certificate No: 548g-(cl-6) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

MCP-C204 Conventional re-settable indoor manualcall point, surface and flush mounting (C-92FC)

548g/03

Page 339: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 329

Certificated Products LPCB Ref. No.

MCP-A204 Digital addressable re-settable indoor manualcall point, surface and flush mounting (C-92FC)

548g/04

Accessories

C-92FC Transparent cover

Nitin Ventures FZEP.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab EmiratesTel: +97 148865858/859 • Fax: +97 148865800E-mail: [email protected] • Website: www.nitinventures.com

Certificate No: 010w-(cl-1) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005

Manual Call PointsCertificated Products LPCB Ref.

No.NV-II-MCP NVI Series Manual Call Point 010w/03NV-II-WMCP Discovery analogue addressable waterproof manual call point with short circuit isolator 010w/06

Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.notifierfiresystems.co.uk

Certificate No: 166e to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005Certificate No: 166b to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

M700KACI-xx Indoor surface/flush mounting addressable call point with short circuit isolator Advanced Protocol (and System Sensor 500 series protocol)

166e/01

Notes:1. xx = S x (Surface mounted) F x (Flush mounted)2. xx = x G (Glass element) x F (Flexible element)3. The above manual call point is approved with three micro-switches (Honeywell ZM10E50A01, Otehall 294/20/150/G and Burgess X4G31051BBAQ)

M700KAC-xx Indoor surface/flush mounting addressable call point Advanced Protocol System Sensor 500 series protocol)

166b/45

Notes:1. xx = S x (Surface mounted) F x (Flush mounted)2. xx = x G (Glass element) x F (Flexible element)

M700WCP-R/I/Sx Outdoor surface mounting addressable waterproof call pointwith short circuit isolator Advanced Protocol System Sensor 500 series protocol)

166e/03

Note: 1. S x = S G (Glass Element) S F (Flexible Element)

Accessories:SR Surface mounting plastic box(1)

SR1T Surface mounting plastic box c/w 1 terminal(1)

SR2T Surface mounting plastic box c/w 2 terminal(1)

SR3T Surface mounting plastic box c/w 3 terminal(1)

SR4T Surface mounting plastic box c/w 4 terminal(1)

ETT European Terminal Tray ETT 1, 2 & 3(1)

L Earth Continuity Link(1)

BZR/1 Bazel Type 1(1)

BZR/2 Bazel Type 2(1)

BZR/3 Bazel Type 3(1)

M141W Spacer Piece(1)

Page 340: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

330 31 Dec 2012

PTR Pattress PTR, PTRE, PTR2T, PTR2TE, PTR3T & PTR3TE(1)

C Hinged Cover(2)

Notes:1. The above accessories are only supplied with M700KAC-xx & M700KACI-xx manual call points2. The hinged cover may be supplied with all models and is optionally indicated by the precence of 'C' at the end of the model number.

Pelco Finland OyKalkkipellontie 6, 02650, Espoo, FinlandTel: +358 10 446 511 • Fax: +358 10 446 5103E-mail: [email protected] • Website: www.pelco.com/nordic

Certificate No: 010n-(cl-1) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

EPP-23E ESMI Intellia analogue addressable waterproof manual call point 010n/08EPP-23P PELCO Intellia analogue addressable waterproof manual call point 010n/08

Protec Fire Detection plcProtec House, Churchill Way, Nelson, Lancashire BB9 6RT, United KingdomTel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273E-mail: [email protected] • Website: www.protec.co.uk

Certificate No: 201ae to EN5-11: 2001 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

6000/MCP Analogue addressable indoor break glass unit(N 63-111-48 mounting box)

201ae/01

6000/MCP/NL Analogue addressable indoor break glass unit Dutch version(N 63-111-48 mounting box)

201ae/02

6000/MCP/EXP Analogue addressable indoor break glass unit Export version(N 63-111-48 mounting box)

201ae/03

Accessories:N 63-111-48 Surface mounting back box

Safety Technology International (Europe) LimitedUnit 49G Pipers Road, Park Farm Industrial Estate, Redditch, Worcestershire B98 0HU, United KingdomTel: +44 (0)1527 520999 • Fax: +44 (0)1527 501999E-mail: [email protected] • Website: www.sti-europe.com

Certificate No: 653a to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

Series 01 Conventional Type A re-settable indoor flush/surface mounted manual call point 653a/01Notes:1) Flush mount approved model RP-RF-01 (M200)2) Surface mount approved model RP-RS-01 (M200 + M125)3) Surface mount approved model RP-RS1-01 (M223)4) Approved colour, red only

AccessoriesM200 wall plate

Page 341: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 331

M125 back boxM223 back box

Sareme UABNaugarduko str. 32/2, Vilnius LT2006, LithuaniaTel: +3705 2135047 • Fax: +3705 2333567E-mail: [email protected]

Certificate No: 512f to EN 54-11:2001 + A1:2005

Certificated Products LPCB Ref. No.

SF MCP127 Conventional manual call point with LED 512f/01SF MCP127-F Conventional manual call point with flashy LED 512f/02SF MCP127-TC Conventional manual call point with LED and transparent cover 512f/03SF MCP127-FTC Conventional manual call point with flashy LED and transparent cover 512f/04

AccessoriesSF MCP127-B1 Regular mounting base, 28mmSF MCP127-B2 High mounting base, 40mmSF MCP127-B3 High mounting base, 55m

Schrack Seconet AGEibesbrunnergasse 18, A112 Wien, AustriaTel: +43-1-81157-0E-mail: [email protected]

Certificate No: 166b to EN 54-11: 2001 + A1: 2005

Manual Call pointsCertificated Products LPCB Ref.

No.MCP545-1 Indoor surface mounting addressable manual call point 166b/35MCP545-2 Indoor flush mounting addressable manual call point 166b/36

Securiton AGAlpenstrasse 20, CH-3052 Zollikofen, Berne, SwitzerlandTel: +41 31 9101122 • Fax: +41 31 9101616E-mail: [email protected]

Certificate No: 166b to EN 54-11: 2001 + A1: 2006

Manual Call pointsCertificated Products LPCB Ref.

No.MCP545-1 Indoor surface mounting addressable manual call point 166b/35MCP545 Indoor flush mounting addressable manual call point 166b/36

Page 342: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

332 31 Dec 2012

SHIELD FIRE, SAFETY AND SECURITY LTD29th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United KingdomTel: +44 207 712 1610 • Fax: +44 207 712 1578E-mail: [email protected] • Website: www.shieldglobal.com

Certificate No: 548g-(cl-4) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

BG-A450 Intelligent manual call point 548g/02BG-C440 Conventional manual call point 548g/01

Siemens Switzerland Limited, Building Technologies DivisionInternational Headquarters, Gubelstrasse 22, CH-6301 Zug, SwitzerlandTel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22

Certificate No: 126w-(cl-1) to EN 54-11: 2001 + A1: 2005Certificate No: 166b to EN 54-11: 2001Certificate No: 126ap-(cl-1) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005Certificate No: 126as to EN 54-11: 2001 + A1: 2005Certificate No: 126ax-(cl-1) to EN 54-11: 2002 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

DM1154 Ex Addressable interactive manual call point 126w/01DM1101 Conventional indoor and outdoor manual call point 126w/02MT320C Conventional indoor and outdoor manual call point 126w/03DM1104 Conventional indoor and outdoor manual call point 126w/06DM1104H Conventional indoor and outdoor manual call point (DMZ1197-AC) 126w/09DM1154H-Ex Addressable interactive manual call point (DMZ1197-AC) 126w/12MT320C Indoor manual call point, flush mounted (single pole changeover) 166b/07DM1101 Indoor manual call point, flush mounted (DMZ1191 mounting box) 166b/11FDM225-RP Digital addressable Type A indoor/outdoor manual call point with resettable plastic

element and incorporating a short circuit isolator (FDMH295-R and FDMH295-S)126ap/01

FDM225-RG Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating a short circuit isolator (FDMH295-R and FDMH295-S)

126ap/02

FDM226-RP Digital addressable Type A indoor/outdoor manual call point with resettable plastic element and incorporating a short circuit isolator (including housing base)

126ap/03

FDM226-RG Digital addressable Type A indoor/outdoor manual call point with resettable plastic element and incorporating a short circuit isolator (including housing base)

126ap/04

FDM224 Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC and DMZ1195)

126ap/05

FDM224H Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC and DMZ1197-AD)

126ap/06

FDM221 Digital addressable Type A indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (FDMC291 and FDMK291)

126ap/07

FDM223 Digital addressable Type B indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC and DMZ1195)

126ap/08

FDM223H Digital addressable Type B indoor/outdoor manual call point with resettable glass element and incorporating short circuit isolator (DMZ1197-AC)

126ap/09

FDM225 RP (F) Digital addressable Type A indoor/outdoor manual call point with re-settable plastic element and incorporating short circuit isolator; French labelling on re-settable plastic element (FDMH295-R and FDMH295-S)

126ap/10

FDM225-RG (F) Digital addressable Type A indoor/outdoor manual call point with non-resettable glass element and incorporating a short circuit isolator; French labelling on non-resettable glass element (FDMH295-R and FDMH295-S)

126ap/11

FDM1101-RG Collective Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element 126as/01FDM1101-RP Collective Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element. 126as/02FDM1101A-RG Conventional Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass

Element.126as/03

FDM1101A-RP Conventional Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element. 126as/04

Page 343: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 333

Certificated Products LPCB Ref. No.

FDM1101-RG(F) Collective Type A Indoor / Outdoor Manual Call Point with Non-Resettable Glass Element.

126as/05

FDM1101-RP(F) Collective Type A Indoor / Outdoor Manual Call Point with Resettable Plastic Element; French labelling on Resettable Plastic Element.

126as/06

DM1131 Analogue addressable indoor and outdoor manual call point with short circuit isolator 126ax/01DM1151 Interactive indoor and outdoor manual call point with short circuit isolator 126ax/02DM1134 Addressable indoor and outdoor manual call point with short circuit isolator 126ax/03DM1154 Interactive indoor and outdoor manual call point with short circuit isolator 126ax/04DM1134H Analogue addressable indoor and outdoor manual call point with short circuit isolator

(DMZ1197-AC)126ax/05

DM1154H Interactive indoor and outdoor manual call point with short circuit isolator(DMZ1197-AC)

126ax/06

Accessories:FDMC291 protective coverFDMK291 key with coverDMZ1197-AC protective coverDMZ1195 keyDMZ1197-AD seal for wet areasBases:FDMH295-R Housing baseFDMH295-S Housing base with holes and sockets

SMS (Novar Systems Ltd)Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016Website: www.smsfire.co.uk

Certificate No: 042aq to EN54-11: 2001+ A1:2005

Certificated Products LPCB Ref. No.

SEN-800 Analogue addressable Type A indoor manual call point(SEN-895 surface mount back box)

042aq/01

Note: Approved for use with glass non re-settable element

SEN-805 Analogue addressable Type A indoor manual call point(SEN-895 surface mount back box)

042aq/05

Note: Approved for use with plastic re-settable element

Accessories:

SEN-895 Surface mount back box

Sterling Safety SystemsUnit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United KingdomTel: +44(0)1926485282 • Fax: +44(0)1926485090E-mail: [email protected] • Website: www.sterlingsafety.co.uk

Certificate No: 928h to EN 54-11: 2001 + A1: 2002 and EN 54-17: 2005Certificate No: 928p-(cl-5) to EN 54-11: 2001 + A1: 2005 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

HFI-CP-01 Analogue addressable Type A indoor re-settable manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

HFW-CP-01 Wireless type A resettable indoor manual call point(SRO1 surface mount back box)

928p/01

Note:1.The device must be used with the following batteries only:CR123A (3Vdc) - main batteryCR2032A (3Vdc) - secondary

Page 344: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

334 31 Dec 2012

AncillariesSR01 Surface mounting boxFlush mounting plate

Synaps Technology SrlPadriciano 99 c/o Area Science Park, Trieste 34149, ItalyTel: 0039 040 3755360 • Fax: 0039 040 3755361E-mail: [email protected] • Website: www.synaps-technology.com

Certificate No: 959a to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

SyCALL R6847L Conventional type A indoor manual call point 959a/01

AncillariesDeep back boxSafety coverWall flush mount plate (white only) and external trim frame (white only)

Teledata S.r.l.Via Giulietti 8, Milan 20132, ItalyTel: +39 02-27201352 • Fax: +39 02-2593704E-mail: [email protected] • Website: www.teledate-i.com

Certificate No: 928h-(cl-7) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

FDVCP100 Analogue addressable Type A resettable indoor manual call point with short circuit isolator (SR01 and Flush mounting plate)

928h/01

AncillariesSR01 Surface mounting boxFlush mounting plate

Thorn Security Limited, trading as Tyco Safety ProductsDunhams Lane, Letchworth SG6 1BE, United KingdomTel: +44 (0)1462 667700 • Fax: +44 (0)1462 667777E-mail: [email protected] • Website: www.tycosafetyproducts-europe.com

Certificate No: 681n-(cl-1) to EN 54-11: 2001 + A1: 2005Certificate No: 166b to EN 54-11: 2001 + A1: 2005Certificate No: 166k-(cl-1) to EN 54-11: 2001 + A1: 2005 and EN 54-17: 2005Certificate No: 681ab-(cl-1) to EN 54-11: 2001 + A1:2005 and EN 54-17: 2005

Manual Call pointsCertificated Products LPCB Ref.

No.CP820 Addressable Type A indoor manual call point 681n/01CP830 Addressable Type A indoor manual call point 681n/02MCP200 Indoor surface/flush mounting conventional call point 166b/41MCP210 Indoor surface/flush mounting conventional call point 166b/41MCP250M Indoor/outdoor surface/flush mounting conventional call point Marine model 166b/41MCP230 Outdoor surface mounting conventional waterproof call point 166b/53MCP260M Outdoor surface mounting conventional waterproof call point Marine model 166b/53MCP820 Indoor surface/flush mounting analogue addressable

Type A call point with short circuit isolator166k/01

Page 345: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 335

Certificated Products LPCB Ref. No.

MCP820M Indoor surface/flush mounting analogue addressableType A call point with short circuit isolator (Marine Version)

166k/02

MCP830 Outdoor surface mounting analogue addressableType A call point with short circuit isolator

681ab/01

MCP830M Outdoor surface mounting analogue addressableType A call point with short circuit isolator (Marine Version)

681ab/02

UTC Fire & Security BVKelvinstraat 7, NL-6003DH, Weert, The NetherlandsTel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com

Certificate No: 092r-(cl-3) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

ZP787-3 Outdoor analogue addressable manual call point, Labelled Ziton 092r/02Accessories:

DMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

ZP787-3-SW Outdoor analogue addressable manual call point, Labelled Ziton 092r/02Accessories:

DMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test key DMN800 Resettable element

EA787-3 Outdoor analogue addressable manual call point, Labelled EST 092r/02Accessories:

DMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

EA787-3-18 Outdoor analogue addressable manual call point, Labelled EST 092r/02Accessories:

DMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

ZP785-3 Analogue addressable indoor manual call point, Labelled Ziton 092r/01Accessories:

DMN787 Surface mounting box with earth terminal, redDM790 Flush mount cradle with connectorsDM795 Flush mount cradle with connectors and forkgripsDMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

BGUI2000LED Analogue addressable indoor manual call point, Labelled Photain Controls 092r/01Accessories:

DMN787 Surface mounting box with earth terminal, redDM790 Flush mount cradle with connectorsDM795 Flush mount cradle with connectors and forkgripsDMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

EA785-3 Analogue addressable indoor manual call point, Labelled EST 092r/01Accessories:

Page 346: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

336 31 Dec 2012

Certificated Products LPCB Ref. No.

DMN787 Surface mounting box with earth terminal, redDM790 Flush mount cradle with connectorsDM795 Flush mount cradle with connectors and forkgripsDMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

EA785-3-18 Analogue addressable indoor manual call point, Labelled EST 092r/01Accessories:

DMN787 Surface mounting box with earth terminal, redDM790 Flush mount cradle with connectorsDM795 Flush mount cradle with connectors and forkgripsDMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

ZP785-3S-SW Analogue addressable indoor manual call point, Labelled Ziton 092r/01Accessories:

DMN787 Surface mounting box with earth terminal, redDM790 Flush mount cradle with connectorsDM795 Flush mount cradle with connectors and forkgripsDMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

CL785-3 Analogue addressable indoor manual call point, Labelled Clymac 092r/01Accessories:

DMN787 Surface mounting box with earth terminal, redDM790 Flush mount cradle with connectorsDM795 Flush mount cradle with connectors and forkgripsDMN782 Hinged transparent MCP protection coverDMN715 EN 54 universal MCP glassDMN784 Call point test keyDMN800 Resettable element

UTC Fire & Security Inc. Trading as Edwards Systems Technology8985 Town Center Parkway, Bradenton, Florida FL34202, USATel: 941 739-42228Website: www.fs.utc.com

Certificate No: 262p-(cl-2) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

SIGI-271-xx Digital addressable indoor manual call point, surface or flush mounted. 262p/01Note:Key: xx denotes special language markings.Blank = No additional markings18 = Polish markings

Accessories:KAC SR3T-P Surface mounted boxKAC ETTI-P Flush mounted box

Page 347: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 5MANUAL CALL POINTS

31 Dec 2012 337

Zeta Alarm Systems by GLT Exports LimitedDetection House, 72-78 Morfa Road, Swansea SA1 2EN, United KingdomTel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176E-mail: [email protected] • Website: www.gltexports.com

Certificate No: 653a-(cl-1) to EN 54-11: 2001 + A1: 2005

Certificated Products LPCB Ref. No.

ZT-CP3 Conventional Type A re-settable indoor flush/surface manual call point. 653a/01Notes:1. Flush mount approved model ZT-CP3/F (M200)2. Surface mount approved model ZT-CP3 (M223)3. Approved colour, red only

Accessories

M200 wall plateM223 back box

Page 348: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

338 31 Dec 2012

A Line Unit is the term given to define devices used for functions other than fire detection, which areconnected to a fire detection and alarm system transmission path or within other components of the fire detection and alarm system e.g. inside Control and Indicating Equipment. For example, the following devices may be regarded as Line Units:

short circuit isolators input/output interfaces

Short-circuit isolators are used to limit the consequences of low parallel resistance faults between the lines of a transmission path of a fire detection and fire alarm system. The transmission path is normally in a loop configuration which is separated into sections by the short circuit isolators, such that a detected fault in a particular section will isolate that particular section allowing other components in other sections on the loop to function correctly.

Input/output devices are intended for different applications, and may therefore have different functions. Their functions are specified by the manufacturer and they are tested and approved against this specification.

This section lists approved Line Units which are connected to a fire detection and alarm system. The initial approval and continued approval processes for Line Units are outlined in scheme document SD038.

Products listed in this section have been approved to: EN 54-17: 2005 Short-circuit isolators EN 54-18: 2005 Input/output devices EN 54-25: 2008 Components using radio links

Audit:Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard.

Notes:1. It is recommended that short circuit isolators and input/output devices are certificated to EN 54-17: 2005

and EN 54-18: 2005 respectively. EN 54-17: 2005 and EN 54-18: 2005 are now harmonised standards for the Construction Products Directive and CE marking is required for most of the European market by 1 December 2008. It is therefore recommended that devices are certificated to EN 54-17: 2005 or EN 54-18: 2005 where applicable as soon as possible.

2. EN 54-25: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 March 2011. It is therefore recommended that radio link components are certificated to EN 54- 25: 2008

3. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

Advanced Electronics Limited34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United KingdomTel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222E-mail: [email protected] • Website: www.Advel.co.uk

Certificate No: 010aa to EN 54-17: 2005Certificate No: 010ag to EN 54-18: 2005Certificate No: 928n-(cl-1) to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008Certificate No: 928r-(cl-1) to EN 54-18: 2005 and EN 54-25: 2008

Page 349: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 339

Line UnitsCertificated Products LPCB Ref.

No.55000-802ADV DIN-Rail Mounted Dual Isolator 010aa/0655000-182ADV DIN-Rail Sounder Controller (5 Amperes) 010ag/0855000-803ADV DIN-Rail Mounted Input/Output Unit

Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg

010ag/10

55000-822ADV DIN-Rail Mounted Switch Monitor 010ag/1320-VW2W100-ADV Wire to wireless translator module 928n/0120-SGCWE100-ADV Wireless conventional system Expander module 928r/0120-SGWE100-ADV Wireless Expander module 928r/02

Advantronic Systems S.L.C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, SpainTel: +34 91 806 2343 • Fax: +34 91 803 1171E-mail: [email protected] • Website: www.advantronic.es

Certificate No: 928n-(cl-2) to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008Certificate No: 928r-(cl-2) to EN 54-18: 2005 and EN 54-25: 2008

Line UnitsCertificated Products LPCB Ref.

No.AVW190AL Wire to wireless translator module 928n/01AVW191AL Wireless convetional system Expander module 928r/01AVW192AL Wireless Expander module 928r/02

Apollo Fire Detectors Limited36 Brookside Road, Havant, Hampshire PO9 1JR, United KingdomTel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754E-mail: [email protected]

Sales Enquiries GermanyApollo Deutschland GmbHTel: +49 5241 330 60 • Fax: +49 5241 330 629E-mail: [email protected]

Sales Enquiries Spain,Apollo EspanaTel: +34 627 988 061 • Fax: +34 949 335 289E-mail: [email protected]

Sales Enquiries China,Apollo Fire Detectors Limited,, Shanghai representative officeTel: +86 21 5237 0922 • Fax: +86 21 5237 0920E-mail: [email protected]

Certificate No: 010aa to EN 54-17:2005Certificate No: 010ag to EN54-18: 2005Certificate No: 010ah to EN54-17: 2005 & EN54-18: 2005

Page 350: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

340 31 Dec 2012

Certificated Products LPCB Ref. No.

45681-284 XP95/Discovery short circuit isolating base 010aa/0155000-875 XP95 analogue addressable mains switch input/output unit 010ag/1655000-588 XP95 analogue addressable 3 channel input/output unit with isolator 010ah/0155000-841 XP95 analogue addressable switch monitor plus with isolator 010ah/0355000-843 XP95 analogue addressable switch monitor with isolator 010ah/0455000-845 XP95 analogue addressable zone monitor unit with isolator 010ah/0555000-847 XP95 analogue addressable input/output unit with isolator 010ah/0655000-849 XP95 analogue addressable output unit with isolator 010ah/0755000-852 XP95 analogue addressable sounder controller with isolator 010ah/0845681-321 XP95 20D negative short circuit isolating base 010aa/0245681-323 XP95 20D positive short circuit isolating base 010aa/0355000-710 XP95 20D positive short circuit isolator 010aa/0455000-720 XP95 20D negative short circuit isolator (45681-211 Base) 010aa/0555000-802 XP95 analogue addressable DIN-rail dual isolator 010aa/0655000-812 XP95 analogue addressable DIN-rail zone monitor 010ah/0255000-181 XP95 analogue addressable DIN-rail 8A sounder controller unit 010ag/0755000-182 XP95 analogue addressable DIN-rail sounder control unit 010ag/0855000-821 XP95 analogue addressable DIN-rail switch monitor plus 010ag/1255000-822 XP95 analogue addressable DIN-rail switch monitor 010ag/1355000-855 XP95 analogue addressable DIN-rail protocol translator - single 010ag/14

Note: to ensure compliance is maintained, all connecting cables to the protocol translator shall be less than 3m.

55000-856 XP95 analogue addressable DIN-rail protocol translator - dual 010ag/15Note: to ensure compliance is maintained, all connecting cables to the protocol translator shall be less than 3m.

55000-760 XP95/Discovery Analogue addressable mini switch monitor with isolator 010ah/0945681-517 Enhanced deep isolating base (White) 010aa/0745681-518 Enhanced deep isolating base (Red) 010aa/0845681-242 XP95 analogue addressable low power relay base 010ag/0145681-245 S65 conventional standard relay base 010ag/0245681-246 S65 conventional auxiliary relay base 010ag/0345681-247 S65 conventional end of line 12V relay base 010ag/0445681-248 S65 conventional end of line 24V relay base 010ag/0545681-508 S65 conventional 12V relay base 010ag/06ORB-RB-10004 Orbis TimeSaver relay base 010ag/17ORB-SW-10005 Orbis Sav-wire base 010ag/1855000-797 XP95 analogue addressable DIN-rail mains input/output unit 010ag/09

Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg.

55000-803 XP95 analogue addressable DIN-rail input/output unit 010ag/10Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg.

55000-804 XP95 analogue addressable DIN-rail output unit 010ag/11Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg.

55000-864 XP95 analogue addressable locally powered zone montior unit with isolator 010ah/10

Argus Security S.r.l.Via del Canneto 14, Valle delle Noghere, 34015 Muggia, Trieste, ItalyTel: +39 (0) 402821110 • Fax: +39 (0) 402823483E-mail: [email protected] • Website: www.argussecurity.it

Certificate No: 928n to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008Certificate No: 928r to EN 54-18: 2005 and EN 54-25: 2008

Line UnitsCertificated Products LPCB Ref.

No.VW2W100 Wire to wireless translator module 928n/01SGCWE100 Wireless conventional system Expander module 928r/01SGWE100 Wireless Expander module 928r/02

Page 351: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 341

Argus-Spectrum65 Serdobolskaya St, St. Petersburg 197342, Russian FederationTel: +7 812 7037500 • Fax: +7 812 7037501E-mail: [email protected] • Website: www.argus-spectr.ru

Certificate No: 928n-(cl-3) to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008Certificate No: 928r-(cl-3) to EN 54-18: 2005 and EN 54-25: 2008

Line UnitsCertificated Products LPCB Ref.

No.VW2W100 Wire to wireless translator module 928n/01SGCWE100 Wireless conventional system Expander module 928r/01SGWE100 Wireless Expander module 928r/01

ATEIS Middle East FZCOLIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab EmiratesTel: +971 4 3262730 • Fax: +971 4 3262731E-mail: [email protected] • Website: www.ateis.ae

Certificate No: 928n-(cl-4) to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008Certificate No: 928r-(cl-4) to EN 54-18: 2005 and EN 54-25: 2008

Line UnitsCertificated Products LPCB Ref.

No.VELOX WLTM100 Wire to wireless translator module 928n/01VELOX WLCEM100 Wireless conventional system Expander module 928r/01VELOX WLEM100 Wireless Expander module 928r/02

Autronica Fire & Security ASPostboks 5620 NO-7483, Trondheim, NorwayTel: +47 73582500 • Fax: +47 73582501E-mail: [email protected] • Website: www.autronicafire.no

Certificate No: 378g-(cl-1) to EN 54-17: 2005

Certificated Products LPCB Ref. No.

116-BBL-100 Addressable indoor beacon with isolator 378g/01Notes: 1) the beacon functionality is not included within the scope of this approval

116-BBL-100/IP Addressable outdoor beacon with isolator 378g/02Notes: 1) the beacon functionality is not included within the scope of this approval

Page 352: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

342 31 Dec 2012

Chubb Fire & SecurityChubb House, Staines Road West, Sunbury-On-Thames, Middlesex TW6 7AR, United KingdomTel: 01932785588E-mail: [email protected] • Website: www.chubb.co.uk

Certificate No: 010ah-(cl-3) to EN 54-18: 2005 and EN54 -17: 2005

Certificated Products LPCB Ref. No.

F850429N XP95 analogue addressable switch monitor plus with isolator 010ah/03F850376N XP95 analogue addressable switch monitor with isolator 010ah/04F3170135N XP95 analogue addressable zone monitor unit with isolator 010ah/05F850352N XP95 analogue addressable input/output unit with isolator 010ah/06F850377N XP95 analogue addressable output unit with isolator 010ah/07F3170138N XP95 analogue addressable sounder controller with isolator 010ah/08

Context Plus LtdExport House, 175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United KingdomTel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817E-mail: [email protected] • Website: www.xportsales.com

Certificate No: 010ap-(cl-2) to EN 54-17: 2005Certificate No: 010ah to EN 54-18: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

45681-505IMC Negative switching isolating base 010ap/0155000-843IMC Analogue addressable switch monitor with isolator 010ah/0455000-845IMC Analogue addressable zone monitor with isolator 010ah/0555000-847IMC Analogue addressable input/output unit with isolator 010ah/0655000-852IMC Analogue addressable sounder control unit with isolator 010ah/08

Detector Electronics Corporation6901 West 110th Street, Minneapolis, Minesota 55438, USATel: +001 952 946 6488E-mail: [email protected] • Website: www.det-tronics.com

Certificate No: 973b to EN 54-17: 2005 and EN 54-18: 2005

Certificated Products LPCB Ref. No.

EQ3730ab(EDIO) Enhanced Discrete Input/Output Module with short circuit isolator 973b/01Note 1: a refers to either D-DIN rail or P-panel mounting

b refers to either W- non-SIL version or T- SIL versionNote 2: The 750XCH-24D Magnecraft relay is an ancillary module used in conjunction

with the EDIO moduleNote 3: The isolation is applied on the LON communication transmission path and not

the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

Note 4: The EQ3730ab(EDIO) is approved for use in an EQ5410 cabinet.EQ3720ab(RM) Eight channel Relay Module with short circuit isolator 973b/02

Note 1: a refers to either D-DIN rail or P-panel mounting b refers to W- non-SIL version only

Note 2: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or

Page 353: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 343

Certificated Products LPCB Ref. No.

zone.Note 3: The EQ3720ab(RM) is approved for use in an EQ5410 cabinet.

EQ3710ab(AIM) Analogue Input Module with short circuit isolator 973b/03Note 1: a refers to either D-DIN rail or P-panel mounting

b refers to W- non-SIL version onlyNote 2: The isolation is applied on the LON communication transmission path and not

the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

Note 3: The EQ3710ab(AIM) is approved for use in an EQ5410 cabinet.EQ25EM(SAM) Signal Audible Module with short circuit isolator 973b/04

Note 1: The 750XCH-24D Magnecraft relay is an ancillary module used in conjunction with the SAM module.

Note 2: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

Note 3: The EQ25EM(SAM) is approved for use in an EQ5410 cabinet.EQ22EM(IDCSC) Initiating Device circuit with short circuit isolator 973b/05

Note 1: The isolation is applied on the LON communication transmission path and not the power transmission path. Refer to the manufacturers installation document 95-8642 with respect to the number of devices to be connected in a group or zone.

Note 2: The EQ22EM(IDCSC) is approved for use in an EQ5410 cabinet.

Finder Elektronik A.S.Liman Mah., 6. Sok., No: 10 07070, Konyaalti, Antalya, TurkeyTel: +9 0242 344 2500 • Fax: +9 0242 344 2120E-mail: [email protected] • Website: www.finder.com.tr

Certificate No: 928n-(cl-5) to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008

Line UnitsCertificated Products LPCB Ref.

No.FF VW2W100 Wire to wireless translator module 928n/01

FIREX Protection System Technology Ltd28-38 Desborough Street, High Wycombe, Bucks, United KingdomTel: +44 (0)1494 601077 • Fax: +44 (0)1494 601011E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 548m-(cl-3) to EN54-18: 2005Certificate No: 548n-(cl-3) to EN54-17: 2005

Certificated Products LPCB Ref. No.

FX9300I Analogue addressable input module 548m/01FX9301I Analogue addressable single input/output module 548m/01FX9503 Loop isolator 548n/01

Page 354: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

344 31 Dec 2012

Gent By Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300E-mail: [email protected] • Website: www.gent.co.uk

Certificate No: 042ba to EN 54-17: 2005 & EN 54-18: 2005Certificate No: 042bp to EN 54-18: 2005, EN 54-17: 2005 and EN 54-4: 1997 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

S4-34410 Analogue addressable 1 input interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes)

042ba/01

S4-34411 Analogue addressable 1 output DIN rail mounting interface module with short circuit isolator, medium voltage.

042ba/02

S4-34415 Analogue addressable 1 output surface mounting interface module with short circuit isolator, medium voltage.

042ba/03

S4-34420 Analogue addressable 1 input and 1 output interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes)

042ba/04

S4-34450 Analogue addressable 4 input / output interface module with short circuit isolator, low voltage. (S4-34490 and S4-34492 boxes)

042ba/05

S4-34440-02 Mains powered Interface Unit (2Ah) 042bp/01S4-34440-12 Mains powered Interface Unit (12Ah) 042bp/02

Accessories:S4-34490 Plastic Box S4-34492 Metal Box

GEZE GmbHReinhold-Vöster-Str. 21-29, D-71229 Leonberg, GermanyTel: +49 (0)7152-203-0 • Fax: +49 (0)7152-203-310E-mail: [email protected] • Website: www.geze.com

Certificate No: 928s-(cl-1) to EN 54-18: 2005

Certificated Products LPCB Ref. No.

GC150B Non-latching relay base 928s/01

Global System Technology PlcLion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United KingdomTel: +44 (0)1283 225 478 • Fax: +44 (0)1283 222 039E-mail: [email protected] • Website: www.gst.uk.com

Certificate No: 548m-(cl-1) to EN54-18: 2005Certificate No: 548n-(cl-1) to EN54-17: 2005

Certificated Products LPCB Ref. No.

I-9300 Analogue addressable input module 548m/01I-9301 Analogue addressable single input/output module 548m/02C-9503 Loop isolator 548n/01

Page 355: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 345

Group 4 Securicor PlcManor Royal, The Manor, Crawley, West Sussex RH10 9UN, United KingdomTel: +44 (0)20 87707000 • Fax: +44 (0)20 87722531Website: www.g4s.com

Certificate No: 548m-(cl-2) to EN54-18: 2005Certificate No: 548n-(cl-2) to EN54-17: 2005

Certificated Products LPCB Ref. No.

GS300I Analogue addressable input module 548m/01GS301I Analogue addressable single input/output module 548m/02GS503C Loop isolator 548n/01

Gulf Security Technology Co., Ltd.No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, ChinaTel: +86 0335 8502434 • Fax: +86 0335 8502532E-mail: [email protected] • Website: www.gst.com.cn

Certificate No: 548n to EN 54-17: 2005Certificate No: 548m to EN 54-18: 2005

Line UnitsCertificated Products LPCB Ref.

No.C-9503 Loop isolator 548n/01 I-9300 Analogue addressable input module 548m/01I-9301 Analogue addressable single input/output module 548m/02I-9319 Addressable Zone Monitor Unit 548m/03

HDRGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132E-mail: [email protected] • Website: www.hochikieurope.com

Certificate No: 164b to EFSG/F/95/007Certificate No: 164q to EN 54-17: 2005 & EN 54-18: 2005Certificate No: 164n to EN 54-17: 2005Certificate No: 164p to EN 54-18: 2005

Line UnitsCertificated Products LPCB Ref.

No.1433100 Dual Zone Monitor 164b/051433620 Intelligent analogue addressable single zone monitor with short circuit isolator 164q/011433560 Intelligent analogue addressable dual input module with short circuit isolator 164q/031433540 Intelligent analogue addressable dual sounder controller with short circuit isolator 164q/051433600 Intelligent analogue addressable dual relay controller with short circuit isolator 164q/071226110 Short Circuit Isolating Base 164n/031433380 Intelligent Analogue addressable powered output module 164p/101433640 Intelligent Analogue addressable single input module 164p/111433690 Analogue Addressable 4 Input, 4 output Plant Control Module with

short circuit isolator164q/13

Note: The device must be in an enclosure as defined in the manufacture installation manual.

Page 356: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

346 31 Dec 2012

Hochiki Europe (UK) LimitedGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132Website: www.hochikieurope.com

Certificate No: 164b to EFSG/F/95/007Certificate No: 164p to EN-54-18: 2005Certificate No: 164q to EN 54-17: 2005 & EN 54-18: 2005Certificate No: 164n to EN 54-17: 2005Certificate No: 928r-(cl-6) to EN 54-18: 2005 and EN 54-25: 2008Certificate No: 928t-(cl-1) to EN 54-18: 2005, EN 54-25: 2008

Line UnitsCertificated Products LPCB Ref.

No.CHQ-Z Dual zone monitor 164b/05CHQ-SZM/OEM(SCI) Intelligent Analogue Addressable Single Zone monitor with Short Circuit Isolator 164q/01CHQ-SZM/DIN(SCI) Intelligent Analogue Addressable Single Zone monitor with Short Circuit Isolator (DIN rail

version)164q/02

CHQ-DIM/OEM(SCI) Intelligent Analogue Addressable Dual Input Module with Short Circuit Isolator 164q/03CHQ-DIM/DIN(SCI) Intelligent Analogue Addressable Dual Input Module with Short Circuit Isolator (DIN rail

version)164q/04

CHQ-DSC/OEM(SCI) Intelligent Analogue Addressable Dual Sounder Controller with Short Circuit Isolator 164q/05CHQ-DSC/DIN(SCI) Intelligent Analogue Addressable Dual Sounder Controller with Short Circuit Isolator (DIN

rail version)164q/06

CHQ-DRC/OEM(SCI) Intelligent Analogue Addressable Dual Relay Controller with Short Circuit Isolator 164q/07CHQ-DRC/DIN(SCI) Intelligent Analogue Addressable Dual Relay Controller with Short Circuit Isolator (DIN

rail version)164q/08

CHQ-SZM/OEM(HFP)-SCI Intelligent analogue addressable single zone monitor with short circuit isolator 164q/01CHQ-DIM/OEM(HFP)-SCI Intelligent analogue addressable dual input module with short circuit isolator 164q/03CHQ-DSC/OEM(HFP)-SCI Intelligent analogue addressable dual sounder controller with short circuit isolator 164q/05CHQ-DRC/OEM(HFP)-SCI Intelligent analogue addressable dual relay controller with short circuit isolator 164q/07YBO-R/SCI(HFP) Short Circuit Isolating Base 164n/03YBO-R/SCI(RED) Short Circuit Isolating Base (RED) 164n/02YBO-R/SCI(WHT) Short Circuit Isolating Base (WHITE) 164n/03YBO-R/SCI Short Circuit Isolating Base 164n/01YBO-R/6R Conventional latching relay base 164p/07YBO-R/6R(WHT) Conventional latching relay base - White 164p/07YBO-R/6RS Conventional latching relay base with integral Schottky diode 164p/08YBO-R/6RS(WHT) Conventional latching relay base with integral Schottky diode - White 164p/08YBO-R/6RN Conventional non-latching relay base 164p/09YBO-R/6RN(WHT) Conventional non-latching relay base - White 164p/09CHQ-POM Intelligent Analogue addressable powered output module 164p/10CHQ-SIM Intelligent Analogue addressable single input module 164p/11CHQ-POM(HFP) Intelligent Analogue addressable powered output module 164p/10CHQ-SIM(HFP) Intelligent Analogue addressable single input module 164p/11CHQ-SZM/M(SCI) Intelligent analogue addressable single zone monitor with short circuit isolator 164q/01CHQ-DIM/M(SCI) Intelligent analogue addressable dual input module with short circuit isolator 164q/03CHQ-DSC/M(SCI) Intelligent analogue addressable dual sounder controller with short circuit isolator 164q/05CHQ-DRC/M(SCI) Intelligent analogue addressable dual relay controller with short circuit isolator 164q/07YBO-R/SCIM Short Circuit Isolating Base 164n/01CHQ-DZM(SCI) Intelligent Analogue Addressable Dual Zone Monitor with short circuit Isolator 164q/09CHQ-DZM/DIN(SCI) Intelligent Analogue Addressable Dual Zone Monitor with short circuit Isolator (DIN rail

version)164q/10

CHQ-DZM(SCI)-IS Intelligent Analogue Addressable Intrinsically Safe Dual Zone Monitor with short circuit Isolator

164q/11

CHQ-DZM/DIN(SCI)-IS Intelligent Analogue Addressable Intrinsically Safe Dual Zone Monitor with short circuit Isolator (DIN rail version)

164q/12

CHQ-PCM/DIN(SCI) Analogue Addressable 4 Input, 4 output Plant Control Module with short circuit isolator

164q/14

Note: The device must be in an enclosure as defined in the manufacture installation manual.

CHQ-PCM(SCI) Analogue Addressable 4 Input, 4 output Plant Control Module with short circuit isolator

164q/13

Note: The device must be in an enclosure as defined in the manufacture installation manual.

CHQ-PCM(HFP)-SCI Analogue Addressable 4 Input, 4 output Device with short circuit isolator 164q/13Note: The device must be in an enclosure as defined in the manufacture installation

Page 357: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 347

Certificated Products LPCB Ref. No.

manual.

RSM-EXP Wireless Expander module 928r/02YBN-R/3(HFP)-SCI Short Circuit Isolating Base 164n/05YBN-R/3(SCI) Short Circuit Isolating Base 164n/04YBN-R/3(WHT)-SCI Short Circuit Isolating Base (white) 164n/05RSM-WTM ESP Wire to Wireless translator module 928t/01

Honeywell Control Systems LimitedHoneywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United KingdomTel: +44 (0)1344 655609 • Fax: +44 (0)1344 655474Website: www.honeywellbuildingsolutions.co.uk

Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005

Certificated Products LPCB Ref. No.

TC841E1019EIS Conventional zone monitor module with resistive end of line 199v/08TC809E1043 Analogue addressable single channel input module with short

short circuit isolator199v/01

TC809E1050 Analogue addressable dual channel input module with short circuit isolator 199v/02TC809E1068 Analogue addressable dual channel input and single channel output module with short

circuit isolator 199v/03

TC810E1032 Single channel output module with short circuit isolator 199v/04TC810E1040 Single channel 240V output module with short circuit isolator 199v/05TC810E1057 Single channel 240V output module, DIN rail mount with short circuit isolator 199v/06TC841E1019 Single channel 240V output module, DIN rail mount with short circuit isolator 199v/07

Honeywell Control Systems LtdHoneywell House, Arlington Business Park, Bracknell, Berkshire RG12 1EB, United KingdomTel: 01344 655609 • Fax: 01344 655474Website: www.honeywellbuildingsolutions.co.uk

Certificate No: 262x-(cl-2) to EN 54-17: 2005

Certificated Products LPCB Ref. No.

XLS-IM Isolator Module (SIGA-MP1, SIGA-MP2 and SIGA-MP2L) 262x/01

Ancillaries:

SIGI-MP1 Mounting PlateSIGA-MP2 Mounting PlateSIGA-MP2L Mounting Plate

INIM Electronics s.r.l.Via Fosso Antico - Loc, Centobuchi, 63033 Monteprandone (AP), ItalyTel: +39 0735 705007 • Fax: +39 0735 704912E-mail: [email protected] • Website: www.inim.biz

Certificate No: 991g to EN 54-17: 2005 and EN 54-18: 2005

Certificated Products LPCB Ref. No.

EM312SR Intelligent analogue addressable Mini input/output module with short circuit isolator 991g/01

Page 358: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

348 31 Dec 2012

Certificated Products LPCB Ref. No.

EU311 Intelligent analogue addressable Micro input/output module with short circuit isolator 991g/02

Kidde Products LtdThame Park Road, Thame, Oxfordshire OX9 3RT, United KingdomTel: +44 (0)1844 265003 • Fax: +44 (0)1844 265156E-mail: [email protected] • Website: www.kfp.co.uk

Certificate No: 010ah-(cl-4) to EN 54-18: 2005 and EN 54 -17: 2005

Certificated Products LPCB Ref. No.

23900-K135 XP95 analogue addressable switch monitor plus with isolator 010ah/0323900-K134 XP95 analogue addressable switch monitor with isolator 010ah/0423900-K136 XP95 analogue addressable zone monitor unit with isolator 010ah/0523900-K132 XP95 analogue addressable input/output unit with isolator 010ah/0623900-K133 XP95 analogue addressable output unit with isolator 010ah/0723900-K137 XP95 analogue addressable sounder controller with isolator 010ah/08

Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.morley-ias.co.uk

Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005Certificate No: 199r to CEA GEI 1-052 Draft 2.0: 11.06.97 & prEN 54-17 Draft: July 2002

Certificated Products LPCB Ref. No.

MI-DMMI Analogue addressable single channel input module with short circuit isolator 199v/01MI-DMM2I Analogue addressable dual channel input module with short circuit isolator 199v/02MI-D2ICMO Analogue addressable dual channel input and single channel output module with short

circuit isolator199v/03

MI-DCMO Single channel output module with short circuit isolator 199v/04MI-D240CMO Single channel 240V output module with short circuit isolator 199v/05MI-240CMO-DIN Single channel 240V output module, DIN rail mount with short circuit isolator 199v/06MI-DCZM Conventional zone interface module 199v/07MI-DISO Short circuit isolator module 199r/01MI-DCZRM Conventional zone monitor module with resistive end of line 199v/08

Multron Systems Pte Ltd217 Kallang Bahru, Multron Building, Singapore 339 347, SingaporeTel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869E-mail: [email protected] • Website: www.multron.com

Certificate No: 548m-(cl-5) to EN54-18: 2005Certificate No: 548n-(cl-5) to EN54-17: 2005

Certificated Products LPCB Ref. No.

MOD-A300 Analogue addressable input module 548m/01MOD-A301 Analogue addressable single input/output module 548m/02MOD-A503 Loop isolator 548n/01

Page 359: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 349

Nitin Ventures FZEP.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab EmiratesTel: +97 148865858/859 • Fax: +97 148865800E-mail: [email protected] • Website: www.nitinventures.com

Certificate No: 010aa-(cl-1) to EN 54-17: 2005Certificate No: 010ah-(cl-2) to EN 54-18: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

NV-IA-IB Short circuit isolating base 010aa/01NV-IAI-DIB Enhanced deep isolating base (Red) 010aa/08NV-IAI-MSM XP95/Discovery analogue addressable mini switch monitor with isolator 010ah/09NV-IA-ISO XP95 20D Negative Short Circuit Isolator (NV-IA-ISOB) 010aa/05NV-IAII-SM XP95 analogue addressable switch monitor with isolator 010ah/04NV-IAII-ZM XP95 analogue addressable zone monitor unit with isolator 010ah/05NV-IAII-IO XP95 analogue addressable input/output unit with isolator 010ah/06NV-IAII-O XP95 analogue addressable output unit with isolator 010ah/07NV-IAII-SC XP95 analogue addressable sounder controller with isolator 010ah/08

NV-IA-ISOB XP95 Isolator Base

Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230300 • Fax: +44 (0)1444 230888E-mail: [email protected] • Website: www.notifierfiresystems.co.uk

Certificate No: 199r to CEA GEI 1-052 Draft 2.0: 11.06.97 & prEN 54-17 Draft: July 2002Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005

Certificated Products LPCB Ref. No.

M700X Short circuit isolator module 199r/01M710 Analogue addressable single channel input module with short circuit isolator 199v/01M720 Analogue addressable dual channel input module with short circuit isolator 199v/02M721 Analogue addressable dual channel input and single channel output module with short

circuit isolator199v/03

M701 Single channel output module with short circuit isolator 199v/04M701-240 Single channel 240V output module with short circuit isolator 199v/05M701-240-DIN Single channel 240V output module, DIN rail mount with short circuit isolator 199v/06M710-CZR Conventional zone monitor module with resistive end of line 199v/08

Panasonic Corporation1668, Fujikata, Tsu-shi, Mie-ken, JapanTel: +46 40 697 70 00 • Fax: +46 40 697 70 99E-mail: [email protected] • Website: http://pesn.panasonic.se

Certificate No: 1012c-(cl-1) to EN 54-18: 2005

Certificated Products LPCB Ref. No.

Type 2842 Intrinsically safe analogue addressable interface barrier unit 1012c/01

Page 360: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

350 31 Dec 2012

Pelco Finland OyKalkkipellontie 6, 02650, Espoo, FinlandTel: +358 10 446 511 • Fax: +358 10 446 5103E-mail: [email protected] • Website: www.pelco.com/nordic

Certificate No: 199x to EN 54-17: 2005Certificate No: 199v to EN 54-17: 2005 and EN 54-18: 2005Certificate No: 010ag-(cl-1) to EN 54-18: 2005Certificate No: 10aa-(cl-2) to EN 54-17: 2005Certificate No: 010ah-(cl-1) to EN 54-18: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

EMISO524 Short circuit isolator 199x/02EM210ECZ Conventional zone interface module 199v/07EM210E-CZR Conventional zone monitor module with resistive end of line 199v/08EMI-401/S Intellia DIN-rail sounder control module 010ag/08EMI-411 Intellia DIN-rail single input - single output module 010ag/10

Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg.

EMI-401 Intellia DIN-rail single output module 010ag/11Note: to ensure compliance is maintained, this device shall be installed within an enclosure weighing greater than 4.75kg.

EMI-410+ Intellia DIN-rail single input+ module 010ag/12EMI-410 Intellia DIN-rail single input module 010ag/13EMI-311/240 Intellia single input - mains switching module 010ag/16EBI-11 Intellia isolating base 010aa/01EMI-400 Intellia DIN-rail dual isolator 010aa/0606728115 Enhanced deep isolating base (white) 010aa/0706728116 Enhanced deep isolating base (red) 010aa/08EMI-333 Intellia three channel input / output unit with isolator 010ah/01EMI-410/CZ Intellia DIN-rail conventional zone module with isolator 010ah/02EMI-310+ Intellia single input+ module with isolator 010ah/03EMI-310 Intellia single input module with isolator 010ah/04EMI-310/CZ Intellia conventional zone monitor module with isolator 010ah/05EMI-311 Intellia single input - single output module with isolator 010ah/06EMI-301 Intellia single output module with isolator 010ah/07EMI-301/S Intellia sounder control module with isolator 010ah/08

Pittway Tecnologica Srl.Via Caboto 19/3, 34147 Trieste, ItalyTel: +39 040 94 90111 • Fax: +39 040 38 2137E-mail: [email protected] • Website: www.systemsensoreurope.com

European Sales:System Sensor Europe, Life Safety Distribution AG, Wilstrasse 11 (Building U31), CH-8610 Uster, SwitzerlandTel: +41 44 943 4424 • Fax: +41 44 943 4399E-mail: [email protected] • Website: www.systemsensor.com

Certificate No: 199r to CEA GEI 1-052 Draft 2.0 (11-06-97) and prEN 54-17 Draft (July 2002)Certificate No: 199x to EN 54-17: 2005Certificate No: 199v to EN 54-17: 2005 & EN 54-18: 2005

Certificated Products LPCB Ref. No.

M200XE Short circuit isolator module 199r/01B524IEFT-1 Short circuit isolator base 199x/01ISO524-1 Short circuit isolator module 199x/02M210E Analogue Addressable single channel input module with short circuit isolator 199v/01

Page 361: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 351

Certificated Products LPCB Ref. No.

M220E Analogue addressable dual channel input module with short circuit isolator 199v/02M221E Analogue addressable dual channel input and single channel output module with short

circuit isolator199v/03

M201E Single channel output module with short circuit isolator 199v/04M201E-240 Single channel 240V output module with short circuit isolator 199v/05M201E-240-DIN Single channel 240V output module, DIN rail mount with short circuit isolator 199v/06M210E-CZ Conventional zone interface module 199v/07M210E-CZR Conventional zone monitor module with resistive end of line 199v/08

Will be labelled as M210E-CZR-yy, where yy indicates the protocol identifier option value between 00 and 99.

Protec Fire Detection plcProtec House, Churchill Way, Nelson, Lancashire BB9 6RT, United KingdomTel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273E-mail: [email protected] • Website: www.protec.co.uk

Certificate No: 201t to EN 54-17: 2005 and EN 54-18: 2005

Certificated Products LPCB Ref. No.

6000/CCO Clean Contact Output Interface Module 201t/016000/MIP Monitored Input Interface Module 201t/036000/MICCO Monitored Input Clean Contact Output Unit 201t/026000/DIU/24V Damper Interface Unit - 24V 201t/046000/DIU/240V Damper Interface Unit - 240V 201t/05

SHIELD FIRE, SAFETY AND SECURITY LTD29th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United KingdomTel: +44 207 712 1610 • Fax: +44 207 712 1578E-mail: [email protected] • Website: www.shieldglobal.com

Certificate No: 548m-(cl-4) to EN54-18: 2005Certificate No: 548n-(cl-4) to EN54-17: 2005

Certificated Products LPCB Ref. No.

AI-500 Analogue addressable input module 548m/01AI-510 Analogue addressable single input/output module 548m/02AI-520 Loop isolator 548n/01

Page 362: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

352 31 Dec 2012

Siemens Switzerland Limited, Building Technologies DivisionInternational Headquarters, Gubelstrasse 22, CH-6301 Zug, SwitzerlandTel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22

Manufacturing at:Siemens Building Technologies AG, Volketswil Factory, Industriestrasse 22, CH-8604 Volketswil, SwitzerlandTel: +41 1 922 6111 • Fax: +41 1 922 6450

UK Sales:Tel: +44 (0)1189 783703 • Fax: +44 (0)1189 775750Website: www.sibt.com/www.uk.cerberus.com

Certificate No: 126m-(cl-1) to EN 54-17: 2005 and EN 54-18: 2005

Approved Products LPCB Ref. No.

DC1192 Input/output module with short circuit isolator 126m/04

Certificate No: 126ae-(cl-1) to EN 54-17: 2005

Certificated Products LPCB Ref. No.

FDCL221 Analogue addressable line separator with short circuit isolator 126ae/01

Accessories:TS35 standard top hat rail

Certificate No: 126ad-(cl-1) to EN 54-17: 2005 and EN 54-18: 2005

Certificated Products LPCB Ref. No.

FDCI222 Analogue addressable input module with short circuit isolator 126ad/01Note:1. Approved when used with FDCH291 or FDCH292 enclosure or in a CIE enclosure compliant with EN 54-2

FDCIO222 Analogue addressable input/output module with short circuit isolator 126ad/02Note:1. Approved when used with FDCH291 or FDCH292 enclosure or in a CIE enclosure compliant with EN 54-2

Accessories:FDCM291 mounting footTS35 standard top hat railFDCH291 enclosureFDCH292 sealed enclosure

Certificate No: 126aq-(cl-1) to EN 54-17:2005 and EN 54-18:2005

Certificated Products LPCB Ref. No.

FDCIO223 Addressable transponder incorporating short circuit isolators(FDCH292, FDCM291)

126aq/01

Note:1. Approved when used in conjunction with housing box FDCH292

FT2001-A1 Digital addressable mimic display driver(F50F410, 520379)

126aq/02

Note:1. Approved when used with a metal enclosure at least complying with protection class IP30 and weighing at least 4.5kg

Page 363: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 353

Certificated Products LPCB Ref. No.

FT2010-A1 Floor repeater terminal 126aq/03FT2011-A1 Floor repeater display 126aq/04

FDCH292 Housing boxFDCM291 Mounting footF50F410 LED flat cable520379 AC/AC Transformer

Certificate No: 531h-(cl-1) to EN 54-17: 2005 and EN 54-18: 2005

Certificated Products LPCB Ref. No.

FDCI221 Analogue addressable input module 531h/01Notes:1. Approved when used with the FDCH221

FDCIO221 Analogue addressable input module 531h/02Notes:1. Approved when used with the FDCH221

Accessories

FDCH221 Enclosure

Certificate No: 126au-(cl-1) to EN 54-17: 2005

Certificated Products LPCB Ref. No.

FDCL221-M Multi line short circuit isolator module 126au/01

SMS (Novar Systems Ltd)Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016Website: www.smsfire.co.uk

Certificate No: 042ba to EN54-18: 2005, EN54-17: 2005

Certificated Products LPCB Ref. No.

SEN-INT-INPUT Analogue addressable 1 input interface module with short circuit isolator low voltage (SEN-490 and SEN-492 boxes).

042ba/01

SEN-INT-ACDIN Analogue addressable 1 output DIN rail mounting interface module with short circuit isolator, medium voltage.

042ba/02

SEN-INT-AC Analogue addressable 1 output surface mounting interface module withshort circuit isolator, medium voltage.

042ba/03

SEN-INT-OUTPUT Analogue addressable 1 input and 1 output interface module with short circuit isolator, low voltage (SEN-490 and SEN-492 boxes)

042ba/04

SEN-INT-4I0 Analogue addressable 4 input / output interface module with short circuit isolator, low voltage (SEN-490 and SEN-492 boxes)

042ba/05

Accessories:

SEN-490 Plastic BoxSEN-492 Metal Box

Page 364: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

354 31 Dec 2012

Sterling Safety SystemsUnit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United KingdomTel: +44(0)1926485282 • Fax: +44(0)1926485090E-mail: [email protected] • Website: www.sterlingsafety.co.uk

Certificate No: 928n-(cl-6) to EN 54-18: 2005, EN 54-17: 2005 and EN 54-25: 2008Certificate No: 928r-(cl-5) to EN 54-18: 2005 and EN 54-25: 2008

Line UnitsCertificated Products LPCB Ref.

No.HFW-W2W-01 Wire to wireless translator module 928n/01HFW-CEM-02 Wireless conventional system Expander module 928r/01HFW-EM-01 Wireless Expander module 928r/01

Thorn Security Limited, trading as Tyco Safety ProductsDunhams Lane, Letchworth SG6 1BE, United KingdomTel: +44 (0)1462 667700 • Fax: +44 (0)1462 667777E-mail: [email protected] • Website: www.tycosafetyproducts-europe.com

Certificate No: 681k-(cl-1) to GEI 1-052: 11-06-97Certificate No: 681t-(cl-1) to EN 54-18: 2005Certificate No: 681u-(cl-1) to EN 54-18: 2005Certificate No: 681v-(cl-1) to EN 54-17: 2005 & EN 54-18: 2005

Certificated Products LPCB Ref. No.

5BI 5" Isolator base 681k/01801IB Digital addressable isolator base 681k/02801RB Digital addressable relay base 681k/03HVR800 High voltage relay module 681t/01

Notes: 1. For use only with RIM800 relay interface module

CIM800 Contact input module 681t/02DIM800 Detector input module 681t/03RIM800 Relay interface module 681t/04MIM800 Mini input module 681t/05SNM800 Sounder notification module 681t/06LAV800 Extinguishing input module 681t/07MIO800 Small addressable multi input/output module 681t/08BDM800 Loop powered beam detector interface module

681u/01

Notes:1. Approved when used in conjunction with the FIRERAY

2000/50R/100R beam detector and BTM800 thermal module

DDM800 Detector driver module with short circuit isolator 681v/01Notes:1. Approved for use with enclosure models

M520 and D8002. The unit is approved when powered from an

EN 54-4 approved power source

Accessories

M520 Standard indoor enclosureD800 Outdoor weatherproof enclosure

Page 365: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 355

UTC Fire & Security BVKelvinstraat 7, NL-6003DH, Weert, The NetherlandsTel: + 31 495 58 30 00 • Fax: + 31 495 55 00 42E-mail: Daragh.O'[email protected] • Website: www.utcfireandsecurity.com

Certificate No: 092w-(cl-1) to EN 54-18:2005Certificate No: 092t-(cl-1) to EN 54-17:2005Certificate No: 092u-(cl-1) to EN 54-18:2005

Certificated Products LPCB Ref. No.

A51E-1 Analogue addressable high voltage relay module 092w/01EA51E-1 Analogue addressable high voltage relay module 092w/01A70E-2 Analogue addressable conventional line interface module 092w/02

Notes:1) The switched alarm output is not approved.

A60E-2 Analogue addressable line isolator module 092t/01EA60E-2 Analogue addressable line isolator module 092t/01ZP7-IB Analogue addressable isolator base 092t/02

Note:1) Approved for use with the following detectors: ZP710-2, ZP720-3, ZP730-2 & ZP732-2.

EA-IB1 Analogue addressable isolator base 092t/02Note:1) Approved for use with the following detectors: EA10E-2, EA20E-3, EA30E-2 & EA32E-2.

ZP752-2 Analogue addressable dual monitored sounder unit 092w/03Note:1) The external power supply must be compliant with EN 54-4

EA752-2 Analogue addressable dual monitored sounder unit 092w/03Note:1) The external power supply must be compliant with EN 54-4

SOUNDI2000 Analogue addressable dual monitored sounder unit 092w/03Note:1) The external power supply must be compliant with EN 54-4

A45E-2 Analogue addressable single input interface module(Labelled Ziton)

092u/01

EA45E-2 Analogue addressable single input interface module(Labelled EST)

092u/01

A50E-2 Analogue addressable line relay module(Labelled Ziton)

092u/02

EA50E-2 Analogue addressable line relay module(Labelled EST)

092u/02

UTC Fire & Security Inc. Trading as Edwards Systems Technology8985 Town Center Parkway, Bradenton, Florida FL34202, USATel: 941 739-42228Website: www.fs.utc.com

Certificate No: 262y-(cl-1) to EN 54-18: 2005Certificate No: 262x-(cl-1) to EN 54-17: 2005Certificate No: 902b-(cl-1) to EN 54-17: 2005

Certificated Products LPCB Ref. No.

SIGA-CC1 Single Input Signal Module 262y/01Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L

Page 366: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

356 31 Dec 2012

Certificated Products LPCB Ref. No.

Note 2: approved with personality code 5SIGA-CC1S Auto-Sync Output Module 262y/02

Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 5

SIGA-CC2 Dual Input Signal Module 262y/03Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 7

SIGA-UM Universal Class A/B Module 262y/04Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2LNote 2: approved with personality codes 3, 4, 8, 11, 12, 15, 16 and 18

SIGA-CR Control Relay Module 262y/05Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 8

SIGA-CR2 Control Relay Module 262y/06Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 8

SIGA-CRR Polarity Reversal Relay Module 262y/07Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 8

SIGA-CT1 Single Input Module 262y/08Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality codes 3, 4 and 18

SIGA-CT2 Dual Input Module 262y/09Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality codes 3, 4 and 18

SIGA-MM1 Monitor Module 262y/10Note 1: approved with the following ancillaries - SIGA-MP1, SIGA-MP2 and SIGA-MP2L Note 2: approved with personality code 3

SIGA-IM Isolator Module (SIGA-MP1, SIGA-MP2 and SIGA-MP2L) 262x/01SIGA-IB Analogue addressable short circuit isolator base 902b/01

Note:1. Certified for used with fire detector models - SIGA-IPHSI, SIGA-PHSI, SIGA-PSI, SIGA-ISI and SIGA-HRSI.

SIGA-IB4 Analogue addressable short circuit isolator base(with 4 inch mounting adaptors)

902b/02

Note:1. Certified for used with fire detector models - SIGA-IPHSI, SIGA-PHSI, SIGA-PSI, SIGA-ISI and SIGA-HRSI.

Ancillaries

SIGA-MP1 Mounting PlateSIGA-MP2 Mounting PlateSIGA-MP2L Mounting Plate

Vimpex LimitedStar Lane, Great Wakering, Essex SS3 0PJ, United KingdomTel: +44 (0) 1702 216999 • Fax: +44 (0) 1702 216699E-mail: [email protected] • Website: www.vimpex.co.uk

Certificate No: 456b to EN 54-17: 2005Certificate No: 456c to EN 54-17: 2005 and EN 54-18: 2005

Certificated Products LPCB Ref. No.

BA873x0/MT/SCI Isolating sounder base (shallow) 456b/01Notes:

1 Key for certification; x indicates body colour: 3 = White, 4 = Red. 2 The device is approved when used with the DINT1 Interface

(refer to LPCB Cert. Ref. 456c). 3 The device is approved when used with the Hosiden Besson

Sounder Banshee MT and Sounder/Strobe LED Flashtone Banshee MT. (refer to LPCB Cert. Ref. 715a).

Page 367: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 6LINE UNITS

31 Dec 2012 357

Certificated Products LPCB Ref. No.

BA873x1/MT/SCI Isolating sounder base (deep) 456b/02Notes:

1 Key for certification; x indicates body colour: 3 = White, 4 = Red. 2 The device is approved when used with the DINT1 Interface

(refer to LPCB Cert. Ref. 456c). 3 The device is approved when used with the Hosiden Besson

Sounder Banshee MT and Sounder/Strobe LED Flashtone Banshee MT. (refer to LPCB Cert. Ref. 715a).

DINT1 Isolating Sounder Interface Card 456c/01Notes:

1. The device is approved for use with the BA873xx/MT/SCI series Isolating Sounder Bases(refer to LPCB Cert. Ref. 456b)

Zeta Alarm Systems by GLT Exports LimitedDetection House, 72-78 Morfa Road, Swansea SA1 2EN, United KingdomTel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176E-mail: [email protected] • Website: www.gltexports.com

Certificate No: 010ap-(cl-1) to EN 54-17: 2005Certificate No: 330k to EN 54-18: 2005 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

80-090 Fyreye FE IB Negative switching isolating base 010ap/01ZIOU-DG Fyreye analogue addressable input/output unit with isolator 330k/01ZIU-MSM Fyreye analogue addressable mini switch monitor with isolator 330k/02

Page 368: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

358 31 Dec 2012

The purpose of a fire alarm warning device is to warn person(s) within, or in the vicinity of, a building of the occurrence of a fire emergency situation in order to enable such person(s) to take appropriate measures. Fire alarm warning devices could be sounders, visual alarm e.g. beacons, or even loudspeakers. These devices can be of different construction and may have different parameters for example sounders are defined in terms of frequency ranges, temporal patterns and output levels, beacons are defined in terms of light temporal pattern and frequency of flashing.

Guidance on the type, frequency, temporal pattern, and output levels should be sought from the applicable installation rule or code of practice - for example BS 5839-1 recommends sounders with continuous output and frequency range between 500 Hz to 1000 Hz.

Fire alarm devices may be used for other type of risk or non-fire emergency alarm. In this case it is always recommended that a different message, colour, temporal pattern, or frequency signal from the fire signal is selected to avoid confusion.

This section lists alarm device approved for use indoors and outdoors in fire detection and fire alarm systems.

Products listed in this section have been approved to: EN 54-3: 2001 Sounders EN 54-3: 2001 + A1: 2002 + A2: 2006 Sounders EN 54-23: 2010 Visual alarms EN 54-24: 2008 Loudspeakers EN 54-25: 2008 Components using radio links

The initial approval and continued approval processes for audible, visual and loudspeaker warning devices are outlined in scheme documents SD115, SD113, and SD039.

Audit:Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard.

Notes:1. EN 54-3: 2001 is now a harmonised standard for the Construction Products Directive and CE marking is

required for most of the European market since 30 June 2005. It is therefore recommended that sounders are certificated to EN 54-3: 2001.

2. EN 54-23: 2010 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 March 2013. It is therefore recommended that sounders are certificated to EN 54-23: 2010.

3. EN 54-24: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 30 April 2011. It is therefore recommended that sounders are certificated to EN 54-24: 2008.

4. EN 54-25: 2008 is now a harmonised standard for the Construction Products Directive and CE marking is required for most of the European market since 1 March 2011. It is therefore recommended that radio link components are certificated to EN 54- 25: 2008

5. Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

Page 369: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 359

Advanced Electronics Limited34 Moorland Way, Nelson Park, Cramlington, Northumberland NE23 1WE, United KingdomTel: +44 (0)1670 707 111 • Fax: +44 (0)1670 707 222E-mail: [email protected] • Website: www.Advel.co.uk

Certificate No: 928g-(cl-5) to EN 54-3: 2001 + A1: 2002 and EN 54 -17: 2005Certificate No: 928q-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

20-VLS100-ADV Analogue addressable Type A sounder with short circuit isolator Notes1. Meets the requirements of EN 54-3 at the following tone settings:

Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady

928g/01

20-SGRBS100-ADV Wireless type A sounder base 928q/01Notes: 1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz 2. Warble 800/1000/1Hz 3. Slow whoop 500-1200Hz 4. Sweep (DIN) 1200-500Hz

2. Approved for use with 20-SG100-ADV, 20-SG200-ADV and SG350-ADV wireless detectors

3. The device must be used with the following batteries only: CR123A (3 Vdc) - main battery CR123A (3 Vdc) - secondary battery

20-SGRBS100-AV-ADV Wireless type A audiovisual sounder base 928q/02Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with 20-SG100-ADV, 20-SG200-ADV and SG350-ADVwireless detectors

3. The Visual Warning part is not approved to EN 54-234. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

20-SGRS100-ADV Wireless type A wall sounder 928q/03Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

20-SGRS100-AV-ADV Wireless type A audiovisual wall sounder 928q/04Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

20-SGRS100-H-ADV Wireless type A Dutch tone wall sounder 928q/05Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz

Page 370: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

360 31 Dec 2012

Certificated Products LPCB Ref. No.

3. Sweep (DIN) 1200-500Hz2. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

20-SGRS100/W-ADV Wireless type A wall sounder white colour 928q/06Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

20-SGRS100-AV/W-ADV Wireless type A audiovisual wall sounder white colour 928q/07Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

20-SGRS100-H/W-ADV Wireless type A Dutch tone wall sounder white colour 928q/08Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

Detectors:

20-SG100-ADV Wireless optical smoke detector20-SG200-ADV Wireless multi-criteria detector20-SG350-ADV Wireless heat detector

Advantronic Systems S.L.C/Yunque 9 Nave B1, Tres Cantos, Madrid 28760, SpainTel: +34 91 806 2343 • Fax: +34 91 803 1171E-mail: [email protected] • Website: www.advantronic.es

Certificate No: 928g-(cl-3) to EN 54-3: 2001 + A1: 2002 and EN 54 -17: 2005Certificate No: 928q-(cl-2) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

AV112AL Analogue addressable Type A sounder with short circuit isolator Notes1. Meets the requirements of EN 54-3 at the following tone settings:

Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady

928g/01

AVW110AL Wireless type A sounder base 928q/01Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

Page 371: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 361

Certificated Products LPCB Ref. No.

2. Approved for use with ATW110A, ATW120A and ATW130A wireless detectors3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

AVW110VAL Wireless type A audiovisual sounder base 928q/02Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with ATW110A, ATW120A and ATW130A wireless detectors3. The Visual Warning part is not approved to EN 54-234. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

AVW112AL Wireless type A wall sounder 928q/03Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

AVW113AL Wireless type A audiovisual wall sounder 928q/04Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

Detectors:

ATW110A Wireless optical smoke detectorATW120A Wireless multi-criteria detectorATW130A Wireless heat detector

Apollo Fire Detectors Limited36 Brookside Road, Havant, Hampshire PO9 1JR, United KingdomTel: +44 (0)2392 492412 • Fax: +44 (0)2392 492754E-mail: [email protected]

Certificate No: 010af to EN 54-3: 2001

Wireless SoundersCertificated Products LPCB Ref.

No.XPA-SO-14001-APO Xpander addressable sounder (Red ) (XPA-SB-10023-APO mounting base) 010af/01

Notes:1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 132) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14001-APO3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells4) The radio link functionality is not included within the scope of approval.

XPA-SO-14002-APO Xpander addressable sounder (White) (XPA-SB-10024-APO mounting base) 010af/02

Page 372: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

362 31 Dec 2012

Certificated Products LPCB Ref. No.

Notes:1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 132) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14002-APO3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells4) The radio link functionality is not included within the scope of approval.

XPA-SN-14003-APO Xpander addressable sounder strobe (Red head / red lens) (XPA-SB-10023-APO mounting base)

010af/03

Notes:1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 132) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14003-APO3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells4) The radio link functionality is not included within the scope of approval.

XPA-SN-14004-APO Xpander addressable sounder beacon (Red head / amber lens) (XPA-SB-10024-APO mounting base)

010af/04

Notes:1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 132) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14004-APO3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells4) The radio link functionality is not included within the scope of approval.

XPA-SN-14005-APO Xpander addressable sounder beacon (White head / clear lens) (XPA-SB-10024-APO mounting base)

010af/05

Notes:1) Meets the requirements of EN 54-3: 2001 at tones 1, 2, 3, 4, 5, 6, 7 & 132) The complete radio base/sounder combination is available as Apollo Part No.: XPA-CB-14005-APO3) The device must be used with the following batteries only: MN1500 LR6 - 1.5 volt alkaline AA cells MN1400 LR14 - 1.5 volt alkaline C cells4) The radio link functionality is not included within the scope of approval.

Bases:XPA-SB-10023-APO Radio link mounting base - redXPA-SB-10024-APO Radio link mounting base - white

Certificate No: 010ak to EN54-3: 2001 +A1:2002 +A2:2006

SoundersCertificated Products LPCB Ref.

No.55000-001 XP95 Type B intelligent open area sounder (Red) 010ak/01

Note:1. Meets the requirements of EN 54-3:2001 at the following tones:Apollo standard-840Hz,0.5s/558Hz,0.5sDutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off German DIN-1200-500Hz over 1s

55000-002 XP95 Type B intelligent open area sounder (White) 010ak/02Note:1. Meets the requirements of EN 54-3:2001 at the following tones:Apollo standard-840Hz,0.5s/558Hz,0.5sDutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off German DIN-1200-500Hz over 1s

55000-005 XP95 Type B intelligent open area sounder beacon (Red) 010ak/03Note:1. Meets the requirements of EN 54-3:2001 at the following tones:Apollo standard-840Hz,0.5s/558Hz,0.5sDutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off German DIN-1200-500Hz over 1s

Page 373: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 363

Certificated Products LPCB Ref. No.

55000-006 XP95 Type B intelligent open area sounder beacon (White) 010ak/04Note:1. Meets the requirements of EN 54-3:2001 at the following tones:Apollo standard-840Hz,0.5s/558Hz,0.5sDutch (slow whoop)- 500-1200Hz in 3.5s, 0.5s off German DIN-1200-500Hz over 1s

58000-005 Discovery Type B intelligent open area sounder beacon (Red)enhanced deep isolating bases)

010ak/05

Note:1. Meets the requirements of EN 54-3:2001 at the following tones:T1- Apollo Evacuation 558Hz,0.5s/840Hz,0.5sT3- Dutch Slow Whoop 500-1200Hz in 3.5s, 0.5s off T4- German DIN1200-500Hz over 1s

58000-007 Discovery Type B intelligent open area sounder beacon (White)enhanced deep isolating bases)

010ak/06

Note:1. Meets the requirements of EN 54-3:2001 at the following tones:T1- Apollo Evacuation 558Hz,0.5s/840Hz,0.5sT3- Dutch Slow Whoop 500-1200Hz in 3.5s, 0.5s off T4- German DIN1200-500Hz over 1s

Bases:

45681-517 Enhanced deep isolating base (White)45681-518 Enhanced deep isolating base (Red)

Argus Security S.r.l.Via del Canneto 14, Valle delle Noghere, 34015 Muggia, Trieste, ItalyTel: +39 (0) 402821110 • Fax: +39 (0) 402823483E-mail: [email protected] • Website: www.argussecurity.it

Certificate No: 928g to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54 -17: 2005Certificate No: 928q to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-25: 2008

SoundersCertificated Products LPCB Ref.

No.VLS100-H Analogue addressable Type A sounder with short circuit isolator

Notes1. Meets the requirements of EN 54-3 at the following tone settings:

Slow whoop tone 500 to 1200Hz, 3s sweep, 0.5s silenceSweep (DIN) tone 1200 to 500Hz, 1Hz

Continuous tone 990Hz, steady

928g/02

VLS100 Analogue addressable Type A sounder with short circuit isolatorNotes

1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone 990 to 650Hz, 2Hz (250ms-250ms)Pulsed tone 990Hz, 1Hz (500ms ON – 500ms OFF)Continuous tone 990Hz, steady

928g/01

SGRBS100 Wireless type A sounder base 928q/01Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz

4. Sweep (DIN) 1200-500Hz2. Approved for use with SG100, SG200 and SG350 wireless detectors3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRBS100-AV Wireless type A audiovisual sounder base 928q/02Notes:

Page 374: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

364 31 Dec 2012

Certificated Products LPCB Ref. No.

1. Meets the requirements of EN54-3 at the following tones:-1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with SG100, SG200 and SG350 wireless detectors3. The Visual Warning part is not approved to EN 54-234. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100 Wireless type A wall sounder 928q/03Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-AV Wireless type A audiovisual wall sounder 928q/04Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-H Wireless type A Dutch tone wall sounder 928q/05Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100/W Wireless type A wall sounder white colour 928q/06Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-AV/W Wireless type A audiovisual wall sounder white colour 928q/07Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-H/W Wireless type A Dutch tone wall sounder white colour 928q/08Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

Page 375: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 365

Certificated Products LPCB Ref. No.

Detectors:

SG100 Wireless optical smoke detectorSG200 Wireless multi-criteria detectorSG350 Wireless heat detector

Argus-Spectrum65 Serdobolskaya St, St. Petersburg 197342, Russian FederationTel: +7 812 7037500 • Fax: +7 812 7037501E-mail: [email protected] • Website: www.argus-spectr.ru

Certificate No: 928g-(cl-2) to EN54-3: 2001 + A1: 2002 and EN 54 -17: 2005Certificate No: 928q-(cl-3) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

VLS100-H Analogue addressable Type A sounder with short circuit isolator Notes1. Meets the requirements of EN 54-3 at the following tone settings:

Slow whoop tone 300 to 1200Hz, 3s sweep, 0.5s silence Sweep (DIN) tone 1200 to 500Hz, 1Hz Continuous tone 990Hz, steady

928g/02

VLS100 Analogue addressable Type A sounder with short circuit isolator Notes1. Meets the requirements of EN 54-3 at the following tone settings:

Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady

928g/01

SGRBS100 Wireless type A sounder base 928q/01Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with SG100, SG200 and SG350 wireless detectors3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRBS100-AV Wireless type A audiovisual sounder base 928q/02Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with SG100, SG200 and SG350 wireless detectors3. The Visual Warning part is not approved to EN 54-234. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100 Wireless type A wall sounder 928q/03Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-AV Wireless type A audiovisual wall sounder 928q/04Notes:

Page 376: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

366 31 Dec 2012

Certificated Products LPCB Ref. No.

1. Meets the requirements of EN54-3 at the following tones:-1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-H Wireless type A Dutch tone wall sounder 928q/05Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100/W Wireless type A wall sounder - white colour 928q/06Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-AV/W Wireless type A audiovisual wall sounder white colour 928q/07Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Alarm part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

SGRS100-H/W Wireless type A Dutch tone wall sounder white colour 928q/08Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

Detectors:

SG100 Wireless optical smoke detectorSG200 Wireless multi-criteria detectorSG350 Wireless heat detector

ATEIS Middle East FZCOLIU 11 Dubai Silicon Oasis, Post Box 293640, Dubai, United Arab EmiratesTel: +971 4 3262730 • Fax: +971 4 3262731E-mail: [email protected] • Website: www.ateis.ae

Certificate No: 928g-(cl-7) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928q-(cl-4) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Page 377: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 367

Certificated Products LPCB Ref. No.

VELOX VLS100 Analogue addressable Type A sounder with short circuit isolator 928g/01Notes:1. Meets the requirements of EN 54-3 at the following tone settings: Dual tone: 990 and 650Hz, 2Hz (250ms-250ms) Pulsed tone: 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone: 990Hz, steady

VELOX VLS100-H Analogue addressable Type A sounder with short circuit isolator 928g/02Notes:1. Meets the requirements of EN 54-3 at the following tone settings: Slow whoop tone 500 to 1200Hz, 3s sweep, 0.5s silence Sweep (DIN) tone 1200 to 500Hz, 1Hz Continuous tone 990Hz, steady

VELOX WLSB100 Wireless type A sounder base 928q/01Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with VELOX WL100, VELOXWL200 AND VELOXWL 350 wireless detectors

3. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

VELOX WLSB100-AV Wireless type A audiovisual sounder base 928q/02Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with VELOX WL100, VELOXWL200 AND VELOXWL 350 wireless detectors

3. The Alarm Warning part is not approved to EN 54-234. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

VELOX WLS100 Wireless type A wall sounder 928q/03Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

VELOX WLS100-AV Wireless type A audiovisual wall sounder 928q/04Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Alarm Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

VELOX WLS100-H Wireless type A Dutch tone wall sounder 928q/05Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

Detectors:

Page 378: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

368 31 Dec 2012

VELOX WL100 Wireless optical smoke detectorVELOX WL200 Wireless multi-criteria detectorVELOX WL350 Wireless heat detector

Autronica Fire & Security ASPostboks 5620 NO-7483, Trondheim, NorwayTel: +47 73582500 • Fax: +47 73582501E-mail: [email protected] • Website: www.autronicafire.no

Certificate No: 378h-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

116-BBQ-230 Addressable indoor sounder and beacon with isolator 378h/01Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)2) the beacon functionality is not included within the scope of this approval

116-BBQ-230/IP Addressable outdoor sounder and beacon with isolator 378h/02Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)2) the beacon functionality is not included within the scope of this approval

116-BBR-230 Addressable indoor sounder with isolator 378h/03Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)

116-BBR-230/IP Addressable outdoor sounder with isolator 378h/04Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)

116-BBR-130 Addressable indoor base sounder with isolator 378h/05Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)

116-BBQ-130 Addressable indoor base sounder and beacon with isolator 378h/06Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)2) the beacon functionality is not included within the scope of this approval

116-BBR-131 Addressable indoor base sounder with isolator 378h/07Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5)

Page 379: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 369

Certificated Products LPCB Ref. No.

- Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)

116-BBQ-131 Addressable indoor base sounder and beacon with isolator 378h/08Notes:1) meets the requirements of EN 54-3: 2001 for the following tones:- General Alarm (880Hz, 7*0.5 sec pulse & 1*5.5) - Evacuate (880Hz, 1 sec on / 1 sec off, forever) - Alert (880Hz On, forever) - Bell Test (0.5 sec on every 8 sec) - Slow Whoop (3.5 sec on / 0.5 sec off, 500-1200 Hz)2) the beacon functionality is not included within the scope of this approval

Bardic by Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Estate, Leicester LE5 1TN, United KingdomTel: +44 (0) 116 246 2212 • Fax: +44 (0) 116 246 2210Website: www.bardic.co.uk

Certificate No: 042bk to EN 54-3: 2001 + A1: 2002 +A2: 2006

Certificated Products LPCB Ref. No.

ZF-IP-SN-ST-RR Conventional Red LP Outdoor Sounder/Strobe Red Lens 042bk/07Notes:1. Meets the requirements of EN 54-3:2001 at Tones:

1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

2. Certification excludes Strobe function.

Bristol Fire LtdThe Colin Saunders Innovation Centre, Mewburn Road, Banbury, Oxfordshire OX16 9PA, United KingdomTel: +44 1295 817623E-mail: [email protected] • Website: www.bristol-fire.com

Certificate No: 506e-(cl-2) to EN 54-3 : 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

BF-AB-0418 Conventional fire alarm bell 506e/01

Ceasefire Industries Ltd"Doli Chambers", Flat 602 6th Floor behind strand cinema, Colaba, Mumbai-400 005, IndiaTel: +91 -22-22854677, 22854678 • Fax: +91-22-66349069E-mail: [email protected] • Website: www.ceasefire.in

Certificate No: 164h-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

YBO-BSB (WHT) Loop powered base sounder and beacon (YBN-R/3 and YBO-R/SCI bases). 164h/031) The beacon function of this device is not included in the scope of this approval.

Page 380: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

370 31 Dec 2012

Certificated Products LPCB Ref. No.

2) Meets the requirements of EN54-3 at the following tones: 1) - 925 Hz : 250 ms / 628 Hz : 250 ms 2) - 925 Hz Continuous 3) - 628 Hz Continuous 4) - (French) 554 Hz : 100 ms/ 440 Hz : 400 ms 5) - (Swedish) 660 Hz : 150 ms/ Off : 150 ms 6) - 925Hz : 15oms / Off : 600 ms 7) - 670 hZ : 250MS / 845 hZ : 370 MS 8) - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9) - 1200 Hz : 500 ms/ 500 Hz : 500 ms

10) - 970 Hz : 500 ms / Off : 500 ms 11) - Sweet 800 Hz - 970 Hz over 140 ms (7 Hz) 12) - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13) - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14) - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15) - Sweet 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16) - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17) - ISO8201 : 970 Hz : 500 ms 18) - ISO8201 : 2850 Hz : 500 ms 19) - 800 Hz : 250 ms / 970 Hz : 250 ms 20) - 2850 Hz Continuous 21) - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22) - 800 Hz : 500 ms / 970 Hz : 500 ms 23) - 2850 Hz : 500 ms / Off : 500 ms 24) - 925 Hz : 250 ms / Off : 1000 ms 25) - 970 Hz Continuous 26) - 660 Hz : 1800 ms / Off: 1800 ms 27) - 660 Hz : 6500 ms / Off : 13000 ms 28) - 660 Hz Continuous 29) - 554 Hz : 500 ms / 440 Hz : 500 ms 30) - 660 Hz : 500 ms / Off : 500 ms 31) - 2850 Hz : 150 ms / Off : 100 ms 32) - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33) - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34) - 988 Hz : 250 ms / 645 Hz : 250 ms 35) - 510 Hz : 250 ms / 610 Hz : 250 ms 36) - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37) - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38) - 845 Hz Continuous 39) - 970 Hz : 1000 ms / Off : 1000 ms 40) - 800 Hz : 150 ms / 970 Hz : 150 ms 41) - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42) - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43) - 2850 Hz : 1000 ms / Off : 1000 ms 44) - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45) - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46) - 440 Hz : 600 ms / Off : 600 ms 47) - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48) - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49) - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50) - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51) - Whoop 500-1200 3.5s/0.5s

BasesYBN -R/3 baseYBO-R/SCI isolator base

Cooper Fulleon LimitedLlantarnam Park, Cwmbran, South Wales NP44 3AW, United KingdomTel: +44 (0)1633 628500 • Fax: +44 (0)1633 866346E-mail: [email protected] • Website: www.cooperfulleon.com

Certificate No: 378b to EN54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

ROLP Roshni Conventional Type A/B LP Sounder 378b/01

Page 381: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 371

Certificated Products LPCB Ref. No.

Notes:1. The sounder is approved in red and white colours2. Using Deep, U-shaped and shallow sounder bases in red and white colours3. Meets the requirements of EN54-3: 2001 at the following tones:

3 - Sweep 800Hz - 970Hz in 1s 7 - Slow whoop 500Hz - 1200Hz in 3.5s - 0.5s silence 8 - Sweep 1200Hz - 500Hz in 1s 14 - Continuous 970Hz steady 29 - Alternating 990Hz 250ms / 650Hz 250ms 30 - Alternating 510Hz 250ms / 610Hz 250ms

ROLP/SV Roshni Conventional Type A/B LP Sounder 378b/02Notes:1. The sounder is approved in red and white colours2. Using Deep, U-shaped and shallow sounder bases in red and white colours3. Meets the requirements of EN54-3: 2001 at the following tones:

3 - Sweep 800Hz - 970Hz in 1s 7 - Slow whoop 500Hz - 1200Hz in 3.5s - 0.5s silence 8 - Sweep 1200Hz - 500Hz in 1s 14 - Continuous 970Hz steady 29 - Alternating 990Hz 250ms / 650Hz 250ms 30 - Alternating 510Hz 250ms / 610Hz 250ms

Cooper Lighting and Safety LtdWheatley Hall Road, Doncaster, South Yorkshire DN2 4NB, United KingdomTel: 01302 303397 • Fax: 01302 303251Website: www.cooper-Is.com

Certificate No: 714j to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

CASB383 Addressable Type A Wall Sounder/Beacon with short circuit isolator 714j/01Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalMASB860 Addressable Type A Wall Sounder/Beacon with short circuit isolator 714j/01

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalFXN539LPS Addressable Type A Wall Sounder/Beacon with short circuit isolator 714j/01

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalCASB383WP Addressable Type B Wall Sounder/Beacon with short circuit isolator 714j/02

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalMASB860WP Addressable Type B Wall Sounder/Beacon with short circuit isolator 714j/02

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

Page 382: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

372 31 Dec 2012

Certificated Products LPCB Ref. No.

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalFXN539LPSWP Addressable Type B Wall Sounder/Beacon with short circuit isolator 714j/02

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalCASBB384 Addressable Type A Sounder/Beacon Base with short circuit isolator 714j/03

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 910Hz- Pulsed 910 / 0Hz pulse 1Hz- Two Tone 610 / 910Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalMASB870 Addressable Type A Sounder/Beacon Base with short circuit isolator 714j/03

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 910Hz- Pulsed 910 / 0Hz pulse 1Hz- Two Tone 610 / 910Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalFXN537 Addressable Type A Sounder/Beacon Base with short circuit isolator 714j/03

Notes:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 910Hz- Pulsed 910 / 0Hz pulse 1Hz- Two Tone 610 / 910Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

2. The beacon functionality is not included within the scope of this approvalCAS380 Addressable Type A Sounder Base with short circuit isolator 714j/04

Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 910Hz- Pulsed 910 / 0Hz pulse 1Hz- Two Tone 610 / 910Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

MAS850 Addressable Type A Sounder Base with short circuit isolator 714j/04Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 910Hz- Pulsed 910 / 0Hz pulse 1Hz- Two Tone 610 / 910Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

FXN538 Addressable Type A Sounder Base with short circuit isolator 714j/04Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 910Hz- Pulsed 910 / 0Hz pulse 1Hz- Two Tone 610 / 910Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

CAS381 Addressable Type A Wall Sounder with short circuit isolator 714j/05Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

MAS850LPS Addressable Type A Wall Sounder with short circuit isolator 714j/05Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

Page 383: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 373

Certificated Products LPCB Ref. No.

FXN538LPS Addressable Type A Wall Sounder with short circuit isolator 714j/05Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

CAS381WP Addressable Type B Wall Sounder with short circuit isolator 714j/06Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

MAS850LPSWP Addressable Type B Wall Sounder with short circuit isolator 714j/06Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

FXN538LPSWP Addressable Type B Wall Sounder with short circuit isolator 714j/06Note:1. Meets the requirements of EN54-3: 2001 for the following tones:

- Continuous 984Hz- Pulsed 984 / 0Hz pulse 1Hz- Two Tone 644 / 984Hz @ 1 Hz cycle- Slow whoop 500-1200Hz in 3.5 seconds / 0.5secs gap

Cranford Controls LimitedUnit 2, Waterbrook Estate, Waterbrook Road, Alton, Hampshire GU34 2UD, United KingdomTel: +44 (0)1420 592444 • Fax: +44 (0)1420 592445E-mail: [email protected] • Website: www.cranfordcontrols.com

Certificate No: 546a to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

VTG-32E-SB Conventional indoor Type A sounder 546a/01Notes:1) The sounder is approved in red and white colours (-R and -W suffixes)2) Certified to EN54-3: 2001 with the following selectable tones:

1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms) 2 nd Stage tone for all above (800Hz continuous tone)11 - 2 nd Stage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off)

VTG-32E-DB Conventional outdoor Type B sounder 546a/01Notes:1) The sounder is approved in red and white colours (-R and -W suffixes)2) Certified to EN54-3: 2001 with the following selectable tones:

1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms) 2 nd Stage tone for all above (800Hz continuous tone) 11 - 2 nd Stage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off)

VPR-DT Conventional outdoor Type B sounder(116-100 mounting base)

546a/02

Notes:1) Certified to EN54-3: 2001 with the following selectable tones:

1 - Evacuate Tone (500-1200Hz Rising Sweep over 3.5 Sec 0.5 Sec off) 2 - Alert Tone (970Hz Continuous Tone)

2) Certified at Maximum Volume only.VSO-32E Conventional indoor Type A sounder base 546a/04

Notes:1) Also approved in Off-white, Ivory and Alternative white (-O, -I, and -A suffixes)

Page 384: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

374 31 Dec 2012

Certificated Products LPCB Ref. No.

2) Meets the requirements of EN 54-3 at the following tone settings on low, medium and high volume settings:

1 - LF Sweep (Cranford sweep) (800-1000Hz @ 0.5 Sec) 3 - Alternative Warble (800-1000Hz @ 0.5 Sec) 11 - Dutch Sweep Tone (970Hz Cont) 25 - German DIN Tone (Sweep 1200-500Hz @ 1Hz) 27- French Tone AFNOR (554Hz 100ms and 440Hz for 400 ms)

3) Cover plate (Part No. 116-099) must be used .

Base:116-100 Viper Mounting Base

EMCO125 El Alamean Street, El Mohandessin, Cairo, EgyptTel: 00202 33 44 3 245 • Fax: 00202 330 36 86 0E-mail: [email protected] • Website: www.4emco.com

Certificate No: 928g to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

AS200 Analogue addressable Type A sounder with short circuit isolator 928g/01Notes:1. Meets the requirements of EN 54-3 at the following tone settings:

Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone 990Hz, steady

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)P.O.Box 22436, Industrial Area 13, Sharjah, United Arab EmiratesTel: +971 6 5340300 • Fax: +971 6 5340090E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 506e to EN 54-3: 2001

Certificated Products LPCB Ref. No.

FX-0218 Conventional fire alarm bell 506e/01

Eurotech Fire Systems Ltd19/20 Stratfield Park, Elettra Avenue, Waterlooville, Hampshire PO7 7XN, United KingdomTel: (0)203 141 0999E-mail: [email protected] • Website: www.eurotechfire.com

Certificate No: 546a-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

EVTG-32E-SB Conventional indoor Type A sounder 546a/01Notes:

1) Approved in red and white colours (-R and -W suffixes) 2) Meets the requirements of EN 54-3 at the following tone settings: 1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms)

Page 385: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 375

Certificated Products LPCB Ref. No.

2 nd Stage tone for all above (800Hz continuous tone) 11 - 2 nd Stage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off)

EVTG-32E-DB Conventional outdoor Type B sounder 546a/01Notes:

1) Approved in red and white colours (-R and -W suffixes) 2) Meets the requirements of EN 54-3 at the following tone settings: 1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms)

2nd Stage tone for all above (800Hz continuous tone) 11 - 2ndStage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off)

EVSO-32E Conventional indoor Type A sounder base 546a/04Notes:

1) Approved in standard white and Eurotech white colours (-W and -EW suffixes).

2) Meets the requirements of EN 54-3 at the following tone settings on low, medium and high volume settings: 1 - LF Sweep (Eurotech sweep) (800-1000Hz @ 0.5 Sec) 3 - Alternative Warble (800-1000Hz @ 0.5 Sec) 11 - Dutch Sweep Tone (970Hz Cont) 25 - German DIN Tone (Sweep 1200-500Hz @ 1Hz) 27- French Tone AFNOR (554Hz 100ms and 440Hz for 400 ms) 3) Cover plate (Part No. 116-099) must be used.

Fike Safety Technology LtdUnit 31, Springvale Industrial Estate, Cwmbran, Gwent NP44 5BD, United KingdomTel: +44 (0)1633 865558 • Fax: +44 (0)1633 866656E-mail: [email protected] • Website: www.fikesafetytechnology.co.uk

Certificate No: 331h to EN 54-3: 2000 + A1: 2002 + A2: 2006Certificate No: 331j to EN 54-3: 2000 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

302-000x Twinflex Hatari Conventional Type A sounder 331h/01Notes:1. Key:

x = 1 Colour Red x = 2 Colour White.

2. Meets the requirements of EN 54-3 at the following tones: - Dual Tone 970Hz 0.25s, 800Hz 0.25s.

302-0012 Twinflex Flashpoint Conventional Type A sounder/strobe 331h/02Note: 1 . Meets the requirements of EN 54-3 at the following tones: -

Dual Tone 970Hz 0.25s, 800Hz 0.25s Slow Whoop 500-1200Hz over 3s, 0.5s off Dual French 550Hz 0.1s, 440Hz 400ms.

302-0022 Twinflex Flashpoint Conventional Type A sounder/strobe (domed) 331h/03Note: 1 . Meets the requirements of EN 54-3 at the following tones: -

Dual Tone 970Hz 0.25s, 800Hz 0.25s Slow Whoop 500-1200Hz over 3s, 0.5s off Dual French 550Hz 0.1s, 440Hz 400ms.

302-0004 Twinflex Hipoint Conventional Type B sounder 331h/04Note: 1 . Meets the requirements of EN 54-3 at the following tones: -

Dual Tone 970Hz 0.25s, 800Hz 0.25s Slow Whoop 500-1200Hz over 3s, 0.5s off Dual French 550Hz 0.1s, 440Hz 400ms.

313-002x Twinflex Soundpoint Conventional Type A sounder 331h/05Notes:1. Key:

x = 1 Colour Red x = 2 Colour White.

2. Meets the requirements of EN 54-3 at the following tones: -

Page 386: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

376 31 Dec 2012

Certificated Products LPCB Ref. No.

Dual Tone 970Hz 0.25s, 800Hz 0.25s Slow Whoop 500-1200Hz over 3s, 0.5s off Dual French 550Hz 0.1s, 440Hz 400ms

326-0001 Sita Analogue Addressable Type A sounder with low profile base and short circuit isolator.

331j/01

Note: 1. Meets the requirements of EN 54-3 at the following tones: -

Continuous 970Hz Pulsed 970Hz 1s on, 1s off Dual Tone 970Hz 0.25s, 800Hz 0.25s Sweep Up 800-970Hz over 1s Slow Whoop 500-1200Hz over 3s, 0.5s off Sweep Down 1200-500Hz over 1s Dual French 550Hz 0.1s, 440Hz 400ms.

326-0003 Sita Analogue Addressable Type A sounder with deep base and short circuit isolator. 331j/02Note: 1. Meets the requirements of EN 54-3 at the following tones: -

Continuous 970Hz Pulsed 970Hz 1s on, 1s off Dual Tone 970Hz 0.25s, 800Hz 0.25s Sweep Up 800-970Hz over 1s Slow Whoop 500-1200Hz over 3s, 0.5s off Sweep Down 1200-500Hz over 1s Dual French 550Hz 0.1s, 440Hz 400ms.

326-0021-R Sita Analogue Addressable Type A sounder/strobe with low profile base and short circuit isolator.

331j/03

Note: 1. Meets the requirements of EN 54-3 at the following tones: -

Continuous 970Hz Pulsed 970Hz 1s on, 1s off Dual Tone 970Hz 0.25s, 800Hz 0.25s Sweep Up 800-970Hz over 1s Slow Whoop 500-1200Hz over 3s, 0.5s off Sweep Down 1200-500Hz over 1s Dual French 550Hz 0.1s, 440Hz 400ms.

326-0023-R Sita Analogue Addressable Type A sounder/strobe with deep base and short circuit isolator.

331j/04

Note: 1. Meets the requirements of EN 54-3 at the following tones: -

Continuous 970Hz Pulsed 970Hz 1s on, 1s off Dual Tone 970Hz 0.25s, 800Hz 0.25s Sweep Up 800-970Hz over 1s Slow Whoop 500-1200Hz over 3s, 0.5s off Sweep Down 1200-500Hz over 1s Dual French 550Hz 0.1s, 440Hz 400ms.

323-0001 Sita Hipoint Analogue Addressable Type B sounder with short circuit isolator. 331j/05Note: 1. Meets the requirements of EN 54-3 at the following tones: -

Continuous 970Hz Pulsed 970Hz 1s on, 1s off Dual Tone 970Hz 0.25s, 800Hz 0.25s Sweep Up 800-970Hz over 1s Slow Whoop 500-1200Hz over 3s, 0.5s off Sweep Down 1200-500Hz over 1s Dual French 550Hz 0.1s, 440Hz 400ms.

313-000x Sita Soundpoint Analogue Addressable Type A sounder with short circuit isolator. 331j/06Notes:1. Key:

x = 1 Colour Red x = 2 Colour White.

2. Meets the requirements of EN 54-3 at the following tones: - Continuous 970Hz Pulsed 970Hz 1s on, 1s off Dual Tone 970Hz 0.25s, 800Hz 0.25s Sweep Up 800-970Hz over 1s Slow Whoop 500-1200Hz over 3s, 0.5s off Sweep Down 1200-500Hz over 1s Dual French 550Hz 0.1s, 440Hz 400ms.

Page 387: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 377

Finder Elektronik A.S.Liman Mah., 6. Sok., No: 10 07070, Konyaalti, Antalya, TurkeyTel: +9 0242 344 2500 • Fax: +9 0242 344 2120E-mail: [email protected] • Website: www.finder.com.tr

Certificate No: 928g-(cl-1) to 54-3: 2001 + A1: 2002 and EN 54 -17: 2005Certificate No: 546a-(cl-2) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.FF LS200 Analogue addressable Type A sounder with short circuit isolator

Notes1. Meets the requirements of EN 54-3 at the following tone settings:

Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON 500ms OFF Continuous tone 990Hz, steady

928g/01

FF ES150-VTG-SB Conventional indoor Type A sounder (SB base) 546a/01Notes:1. The sounder is approved in red and white colours (-R and -W suffixes)2. Certified to EN54-3: 2001 with the following selectable tones:

1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms) 2 nd Stage tone for all above (800Hz continuous tone) 11 - 2 nd Stage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off)

FF ES150-VTG-DB Conventional outdoor Type B sounder (DB base) 546a/01Notes:1. The sounder is approved in red and white colours (-R and -W suffixes)2. Certified to EN54-3: 2001 with the following selectable tones:

1 - LF Sweep frequency (800-1000Hz in 0.5sec) 25 - German DIN tone Sweep (1200-500Hz @ 1Hz) 27 - French tone AFNOR (554Hz for 100ms and 440Hz for 400ms) 2 nd Stage tone for all above (800Hz continuous tone) 11 - 2 nd Stage, Dutch sweep tone (500-1200Hz for 3.5s on, 0.5s off)

Bases:SB : Shallow base (type A)DB : Deep base (type B)

Fireguard Safety Equipment Co Ltd2nd Floor, 145-147 St John Street, London EC1V 4PY, United KingdomTel: +44 (0)8450 751042 • Fax: +44 (0)845 2991039E-mail: [email protected] • Website: www.fireguard-uk.com

Certificate No: 506e-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

FG-0218 Conventional fire alarm bell 506e/01

Page 388: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

378 31 Dec 2012

FIREX Protection System Technology Ltd28-38 Desborough Street, High Wycombe, Bucks, United KingdomTel: +44 (0)1494 601077 • Fax: +44 (0)1494 601011E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 548e-(cl-3) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.FX9403 Conventional sounder strobe (Shallow and Deep Bases) 548e/01

Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval.

FX9403I Intelligent sounder strobe (Shallow and Deep Bases) 548e/02Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off Pre Alarm 800Hz, 1s on / 1s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval 4. Approved with single address and dual address (pre-alarm and main alarm).

BasesShallow BaseDeep base

Gent By Honeywell (Novar Systems Ltd)140 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2000 • Fax: +44 (0)116 246 2300E-mail: [email protected] • Website: www.gent.co.uk

Certificate No: 042bj to EN 54-3: 2001 + A1: 2002 + A2: 2006, EN 54-17: 2005Certificate No: 042bk to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

S3-SN-R-V2 Addressable Red LP Indoor Sounder with short circuit isolator 042bj/01Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

S3-SN-W-V2 Analogue Addressable White LP Indoor Sounder with short circuit isolator 042bj/02Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

S3IP-SN-R-V2 Analogue Addressable Red Outdoor Sounder with short circuit isolator 042bj/03Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

S3IP-SN-W-V2 Analogue Addressable White Outdoor Sounder with short circuit isolator 042bj/04Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz.

Page 389: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 379

Certificated Products LPCB Ref. No.

3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

S2IP-SN-R-V2 Analogue Addressable Red Outdoor Sounder with short circuit isolator 042bj/05Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

S2IP-SN-R-V2 Analogue Addressable Red Outdoor Sounder with short circuit isolator 042bj/05Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

S2IP-SN-W-V2 Analogue Addressable White Outdoor Sounder with short circuit isolator 042bj/06Note: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

S3-SN-ST-RR-V2 Analogue Addressable Red LP Indoor Sounder/Strobe Red Lens with short circuit isolator

042bj/07

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3-SN-ST-WR-V2 Analogue Addressable White LP Indoor Sounder/Strobe Red Lens with short circuit isolator

042bj/08

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3IP-SN-ST-RR-V2 Analogue Addressable Red Outdoor Sounder/Strobe Red Lens with short circuit isolator 042bj/09Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3IP-SN-ST-WR-V2 Analogue Addressable White Outdoor LP Sounder/Strobe Red Lens with short circuit isolator

042bj/10

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3IP-SN-ST-RW-V2 Analogue Addressable Red Outdoor Sounder/Strobe White Lens with short circuit isolator

042bj/11

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S2IP-VP-R Analogue Addressable Red Outdoor System Voice Enhanced Sounder with short circuit isolator

042bj/12

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3-VP-R Analogue Addressable Red LP Indoor Sounder Voice Enhanced with short circuit isolator 042bj/13Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz.

Page 390: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

380 31 Dec 2012

Certificated Products LPCB Ref. No.

6. Continuous 970 Hz.2. Certification excludes strobe function.

S3-VP-W Analogue Addressable White LP Indoor Sounder Voice Enhanced with short circuit isolator

042bj/14

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3-VP-ST-WR Analogue Addressable White LP Indoor Sounder Voice Enhanced /Strobe Red Lens with short circuit isolator

042bj/15

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3-VP-ST-RR Analogue Addressable Red LP Indoor Sounder Voice Enhanced /Strobe Red Lens with short circuit isolator

042bj/16

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3IP-VP-R Analogue Addressable Red Outdoor LP Sounder Voice Enhanced with short circuit isolator

042bj/17

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3IP-VP-W Analogue Addressable White Outdoor LP Sounder Voice Enhanced with short circuit isolator

042bj/18

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3IP-VP-ST-WR Analogue Addressable White Outdoor LP Sounder Voice Enhanced / Strobe Red Lens with short circuit isolator

042bj/19

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

S3IP-VP-ST-RR Analogue Addressable Red Outdoor LP Sounder Voice Enhanced / Strobe Red Lens with short circuit isolator

042bj/20

Notes: 1. Meets the requirements of EN 54-3:2001 at tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes strobe function.

C3-SN-R Conventional Red LP Indoor Sounder 042bk/01Note: Meets the requirements of EN 54-3:2001 at Tones:1. Alternating tone 800/970 Hz @ 2Hz.3. Intermittent tone 970 Hz @ 1Hz.6. Continuous 970 Hz.

C3-SN-W Conventional White LP Indoor Sounder 042bk/02Note: Meets the requirements of EN 54-3:2001 at Tones:1. Alternating tone 800/970 Hz @ 2Hz.3. Intermittent tone 970 Hz @ 1Hz.6. Continuous 970 Hz.

C3IP-SN-R Conventional Red LP Outdoor Sounder 042bk/03

Page 391: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 381

Certificated Products LPCB Ref. No.

Note: Meets the requirements of EN 54-3:2001 at Tones:1. Alternating tone 800/970 Hz @ 2Hz.3. Intermittent tone 970 Hz @ 1Hz.6. Continuous 970 Hz.

C3IP-SN-W Conventional White LP Outdoor Sounder 042bk/04Note: Meets the requirements of EN 54-3:2001 at Tones:1. Alternating tone 800/970 Hz @ 2Hz.3. Intermittent tone 970 Hz @ 1Hz.6. Continuous 970 Hz.

C3-SN-ST-RR Conventional Red LP Indoor Sounder/Strobe Red Lens 042bk/05Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes Strobe function.

C3-SN-ST-WR Conventional White LP Indoor Sounder/Strobe Red Lens 042bk/06Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes Strobe function.

C3IP-SN-ST-RR Conventional Red LP Outdoor Sounder/Strobe Red Lens 042bk/07Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes Strobe function.

C3IP-SN-ST-WR Conventional White LP Outdoor Sounder/Strobe Red Lens 042bk/08Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes Strobe function.

C3-VP-ST-RR Conventional Red LP Indoor Sounder Voice Enhanced /Strobe Red Lens 042bk/09Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes Strobe function.

C3-VP-ST-WR Conventional White LP Indoor Sounder Voice Enhanced /Strobe Red Lens 042bk/10Notes: 1. Meets the requirements of EN 54-3:2001 at Tones: 1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.2. Certification excludes Strobe function.

Bases:Shallow Base – IP31CDeep Base – IP55CNote – All products may be used with either base

Page 392: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

382 31 Dec 2012

Global System Technology PlcLion Court, Staunton Harold Hall, Melbourne Road, Ashby de la Zouch, Leicestershire LE65 1RT, United KingdomTel: +44 (0)1283 225 478 • Fax: +44 (0)1283 222 039E-mail: [email protected] • Website: www.gst.uk.com

Certificate No: 548e-(cl-5) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.C-9403 Conventional sounder strobe (Shallow and Deep Bases) 548e/01

Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval.

I-9403 Intelligent sounder strobe (Shallow and Deep Bases) 548e/02Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off Pre Alarm 800Hz, 1s on / 1s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval 4. Approved with single address and dual address (pre-alarm and main alarm).

Group 4 Securicor PlcManor Royal, The Manor, Crawley, West Sussex RH10 9UN, United KingdomTel: +44 (0)20 87707000 • Fax: +44 (0)20 87722531Website: www.g4s.com

Certificate No: 548e-(cl-2) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.GS403C Conventional sounder strobe (Shallow and Deep Bases) 548e/01

Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval.

GS403I Intelligent sounder strobe (Shallow and Deep Bases) 548e/02Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off Pre Alarm 800Hz, 1s on / 1s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval 4. Approved with single address and dual address (pre-alarm and main alarm).

BasesShallow BaseDeep base

Page 393: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 383

Gulf Security Technology Co., Ltd.No 80 Changjiang East Road, QETDZ, Qinhuangdao, Hebei Province 066004, ChinaTel: +86 0335 8502434 • Fax: +86 0335 8502532E-mail: [email protected] • Website: www.gst.com.cn

Certificate No: 548e to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.C-9403 Conventional sounder strobe (Shallow and Deep Bases) 548e/01

Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval.

I-9403 Intelligent sounder strobe (Shallow and Deep Bases) 548e/02Notes: 1. Meets the requirements of EN 54-3: 2001at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off Pre Alarm 800Hz, 1s on / 1s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval 4. Approved with single address and dual address (pre-alarm and main alarm).

BasesShallow BaseDeep base

HDRGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132E-mail: [email protected] • Website: www.hochikieurope.com

Certificate No: 164h to EN 54 3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

1460040 Intelligent analogue addressable Type A base sounder (1426010 and 1226110 bases)

164h/01

Notes:1) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz)

Page 394: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

384 31 Dec 2012

Certificated Products LPCB Ref. No.

17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

1460070 Intelligent analogue addressable Type A base sounder and beacon (1426010 and 1226110 bases)

164h/03

Notes1) The beacon function of this device is not included in the scope of this approval2) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz)

Page 395: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 385

Certificated Products LPCB Ref. No.

33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

1460050 Intelligent analogue addressable Type A wall sounder (1426010 and 1226110 bases)

164h/02

Notes:1) Meets the requirements of EN 54-3 at the following tones:

H1 - 925/628 at 2Hz H4 - French 554: 100ms / 440: 400ms H5 - Swedish 660: 150ms / Off: 150ms 8 - Whoop 500-1200 3s/0.5s 12 - Sweep 800/970 at 1Hz 15 - Sweep 2400-2850 at 1Hz 17 - 970:ISO8201 0.5s 18 - 2850:ISO820 0.5s

1460090 Intelligent analogue addressable Type A wall sounder beacon (1426010 and 1226110 bases)

164h/04

Note:1 The beacon function of this device is not included in the scope of this

approval2 Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms10 - 970 Hz : 500 ms / Off : 500 ms11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz)12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz)13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz)14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz)15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz)16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz)17 - ISO8201 : 970 Hz : 500 ms18 - ISO8201 : 2850 Hz : 500 ms19 - 800 Hz : 250 ms / 970 Hz : 250 ms20 - 2850 Hz Continuous21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms22 - 800 Hz : 500 ms / 970 Hz : 500 ms23 - 2850 Hz : 500 ms / Off : 500 ms24 - 925 Hz : 250 ms / Off : 1000 ms25 - 970 Hz Continuous26 - 660 Hz : 1800 ms / Off: 1800 ms27 - 660 Hz : 6500 ms / Off : 13000 ms28 - 660 Hz Continuous

29 - 554 Hz : 500 ms / 440 Hz : 500 ms30 - 660 Hz : 500 ms / Off : 500 ms31 - 2850 Hz : 150 ms / Off : 100 ms32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz)33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz)34 - 988 Hz : 250 ms / 645 Hz : 250 ms

Page 396: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

386 31 Dec 2012

Certificated Products LPCB Ref. No.

35 - 510 Hz : 250 ms / 610 Hz : 250 ms36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz)37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz)38 - 845 Hz Continuous39 - 970 Hz : 1000 ms / Off : 1000 ms40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz)42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz)43 - 2850 Hz : 1000 ms / Off : 1000 ms44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms46 - 440 Hz : 600 ms / Off : 600 ms47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms51 - Whoop 500-1200 3.5s/0.5s

Bases:1226110 Isolator base 1426010 Standard Base

Hochiki Europe (UK) LimitedGrosvenor Road, Gillingham Business Park, Gillingham, Kent ME8 0SA, United KingdomTel: +44 (0)1634 260133 • Fax: +44 (0)1634 260132Website: www.hochikieurope.com

Certificate No: 164h to EN 54 3: 2001 + A1: 2002 + A2: 2006Certificate No: 928q-(cl-6) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

YBO-BS(HFP) Intelligent analogue addressable Type A base sounder white version (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/01

Note:1) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz)14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz)

15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms

Page 397: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 387

Certificated Products LPCB Ref. No.

30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

YBO-BS(WHT) Intelligent analogue addressable Type A base sounder white version (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/01

Note:1) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms

Page 398: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

388 31 Dec 2012

Certificated Products LPCB Ref. No.

46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

CHQ-WS2(HFP) Intelligent analogue addressable Type A wall sounder (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/02

Note:1) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

CHQ-WS2(WHT) Intelligent analogue addressable Type A wall sounder - white version (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/02

Note:1) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms

Page 399: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 389

Certificated Products LPCB Ref. No.

6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

CHQ-WS2/W Intelligent analogue addressable Type B wall sounder- weatherproof version(YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/02

Note:1) Meets the requirements of EN 54-3 at the following tones:2) Includes a WS2-WPK weatherproofing kit

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms

Page 400: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

390 31 Dec 2012

Certificated Products LPCB Ref. No.

20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

YBO-BSB(HFP) Intelligent analogue addressable Type A base sounder and beacon white version(YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/03

Notes:1) The beacon function of this device is not included in the scope of this approval2) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms

7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms

Page 401: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 391

Certificated Products LPCB Ref. No.

35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

YBO-BSB(WHT) Intelligent analogue addressable Type A base sounder and beacon white version(YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/03

Notes:1) The beacon function of this device is not included in the scope of this approval2) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms

Page 402: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

392 31 Dec 2012

Certificated Products LPCB Ref. No.

50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

YBO-BS Intelligent analogue addressable Type A base sounder (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/01

Notes:1) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

YBO-BSB Intelligent analogue addressable Type A base sounder and beacon(YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/03

Notes:1) The beacon function of this device is not included in the scope of this approval2) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms

Page 403: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 393

Certificated Products LPCB Ref. No.

9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms 25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

CHQ-WS2 Intelligent analogue addressable Type A wall sounder (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/02

Note:1) Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms 10 - 970 Hz : 500 ms / Off : 500 ms 11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz) 12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz) 13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz) 14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz) 15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz) 16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz) 17 - ISO8201 : 970 Hz : 500 ms 18 - ISO8201 : 2850 Hz : 500 ms 19 - 800 Hz : 250 ms / 970 Hz : 250 ms 20 - 2850 Hz Continuous 21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms 22 - 800 Hz : 500 ms / 970 Hz : 500 ms 23 - 2850 Hz : 500 ms / Off : 500 ms 24 - 925 Hz : 250 ms / Off : 1000 ms

Page 404: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

394 31 Dec 2012

Certificated Products LPCB Ref. No.

25 - 970 Hz Continuous 26 - 660 Hz : 1800 ms / Off: 1800 ms 27 - 660 Hz : 6500 ms / Off : 13000 ms 28 - 660 Hz Continuous 29 - 554 Hz : 500 ms / 440 Hz : 500 ms 30 - 660 Hz : 500 ms / Off : 500 ms 31 - 2850 Hz : 150 ms / Off : 100 ms 32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz) 33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz) 34 - 988 Hz : 250 ms / 645 Hz : 250 ms 35 - 510 Hz : 250 ms / 610 Hz : 250 ms 36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz) 37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz) 38 - 845 Hz Continuous 39 - 970 Hz : 1000 ms / Off : 1000 ms 40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz) 42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz) 43 - 2850 Hz : 1000 ms / Off : 1000 ms 44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms 46 - 440 Hz : 600 ms / Off : 600 ms 47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms 48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms 49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms 50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms 51 - Whoop 500-1200 3.5s/0.5s

CHQ-WSB Intelligent analogue addressable Type A wall sounder beacon (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/04

Note:1. The beacon function of this device is not included in the scope of this approval2. Type B weatherproof when used with a WS2-WPK weatherproofing kit3. Meets the requirements of EN 54-3 at the following tones:

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms10 - 970 Hz : 500 ms / Off : 500 ms11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz)12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz)13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz)14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz)15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz)16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz)17 - ISO8201 : 970 Hz : 500 ms18 - ISO8201 : 2850 Hz : 500 ms19 - 800 Hz : 250 ms / 970 Hz : 250 ms20 - 2850 Hz Continuous21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms22 - 800 Hz : 500 ms / 970 Hz : 500 ms23 - 2850 Hz : 500 ms / Off : 500 ms24 - 925 Hz : 250 ms / Off : 1000 ms25 - 970 Hz Continuous26 - 660 Hz : 1800 ms / Off: 1800 ms27 - 660 Hz : 6500 ms / Off : 13000 ms28 - 660 Hz Continuous

29 - 554 Hz : 500 ms / 440 Hz : 500 ms30 - 660 Hz : 500 ms / Off : 500 ms31 - 2850 Hz : 150 ms / Off : 100 ms32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz)33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz)34 - 988 Hz : 250 ms / 645 Hz : 250 ms35 - 510 Hz : 250 ms / 610 Hz : 250 ms36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz)

Page 405: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 395

Certificated Products LPCB Ref. No.

37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz)38 - 845 Hz Continuous39 - 970 Hz : 1000 ms / Off : 1000 ms40 - 800 Hz : 150 ms / 970 Hz : 150 ms 41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz)42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz)43 - 2850 Hz : 1000 ms / Off : 1000 ms44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms46 - 440 Hz : 600 ms / Off : 600 ms47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms51 - Whoop 500-1200 3.5s/0.5s

CHQ-WSB (WHT) Intelligent analogue addressable Type A wall sounder beacon (YBN-R/3, YBO-R/SCI, YBN-R/3-SF-R/XXX(YY), YBO-R/3-SF-R/XXX(YY), YBO-R/SCI-SF-R/XXX(YY) and YBO-R/SCI-SF-S/XXX(FL) bases)

164h/04

Note:1 The beacon function of this device is not included in the scope of this approval2 Meets the requirements of EN 54-3 at the following tones:3. Type B weatherproof when used with a WS2-WPK(WHT) weatherproofing kit

1 - 925 Hz : 250 ms / 628 Hz : 250 ms 2 - 925 Hz Continuous 3 - 628 Hz Continuous 4 - (French) 554 Hz : 100 ms / 440 Hz : 400 ms 5 - (Swedish) 660 Hz : 150 ms / Off : 150 ms 6 - 925 Hz : 150 ms / Off : 600 ms 7 - 670 Hz : 250 ms / 845 Hz : 370 ms 8 - Whoop 500 Hz - 1200 Hz : 3000 ms / Off : 500 ms 9 - 1200 Hz : 500 ms / 500 Hz : 500 ms10 - 970 Hz : 500 ms / Off : 500 ms11 - Sweep 800 Hz - 970 Hz over 140 ms (7 Hz)12 - Sweep 800 Hz - 970 Hz over 1000 ms (1 Hz)13 - Sweep 800 Hz - 970 Hz over 20 ms (50 Hz)14 - Sweep 2400 Hz - 2850 Hz over 140 ms (7 Hz)15 - Sweep 2400 Hz - 2850 Hz over 1000 ms (1 Hz)16 - Sweep 300 Hz - 1200 Hz over 1000 ms (1 Hz)17 - ISO8201 : 970 Hz : 500 ms18 - ISO8201 : 2850 Hz : 500 ms19 - 800 Hz : 250 ms / 970 Hz : 250 ms20 - 2850 Hz Continuous21 - 2400 Hz : 250 ms / 2850 Hz : 250 ms22 - 800 Hz : 500 ms / 970 Hz : 500 ms23 - 2850 Hz : 500 ms / Off : 500 ms24 - 925 Hz : 250 ms / Off : 1000 ms25 - 970 Hz Continuous26 - 660 Hz : 1800 ms / Off: 1800 ms27 - 660 Hz : 6500 ms / Off : 13000 ms28 - 660 Hz Continuous29 - 554 Hz : 500 ms / 440 Hz : 500 ms30 - 660 Hz : 500 ms / Off : 500 ms31 - 2850 Hz : 150 ms / Off : 100 ms32 - Sweep 2400 Hz - 2850 Hz over 20 ms (50 Hz)33 - Sweep 800 Hz - 970 Hz over 500 ms (2 Hz)34 - 988 Hz : 250 ms / 645 Hz : 250 ms35 - 510 Hz : 250 ms / 610 Hz : 250 ms36 - Sweep 800 Hz - 970 Hz over 110 ms (9 Hz)37 - Sweep 800 Hz - 970 Hz over 330 ms (3 Hz)38 - 845 Hz Continuous39 - 970 Hz : 1000 ms / Off : 1000 ms40 - 800 Hz : 150 ms / 970 Hz : 150 ms41 - Sweep 2400 Hz - 2850 Hz over 110 ms (9 Hz)42 - Sweep 2400 Hz - 2850 Hz over 330 ms (3 Hz)43 - 2850 Hz : 1000 ms / Off : 1000 ms44 - 2400 Hz : 150 ms / 2850 Hz : 150 ms 45 - (German) Whoop 1200 Hz - 500 Hz : 1000ms / Off : 10 ms46 - 440 Hz : 600 ms / Off : 600 ms47 - Whoop 500 Hz - 1200 Hz : 3750 ms / Off : 250 ms48 - ISO8201 : 925 Hz, 628 Hz : 250 ms / Off 500 ms49 - ISO8201 : Sweep 300 Hz - 1200 Hz : 500 ms / Off : 500 ms

Page 406: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

396 31 Dec 2012

Certificated Products LPCB Ref. No.

50 - ISO8201 : Sweep 1200 Hz - 300 Hz : 500 ms / Off : 500 ms51 - Whoop 500-1200 3.5s/0.5s

RSM-BS Wireless type A sounder base 928q/01Note:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with ROD-E, RMD-E and RHD-E wireless detectors3. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

RSM-BSB Wireless type A audiovisual sounder base 928q/02Note:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with ROD-E, RMD-E and RHD-E wireless detectors3. Does not incorporate approval to EN 54-234. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

RSM-WS (RED) Wireless type A wall sounder 928q/03Note:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

RSM-WSB (RED) Wireless type A audiovisual wall sounder 928q/04Note:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Does not incorporate approval to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

RSM-WS (WHT) Wireless type A wall sounder white colour 928q/06Note:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

RSM-WSB (WHT) Wireless type A audiovisual wall sounder white colour 928q/07Note:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Does not incorporate approval to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

Bases:

Page 407: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 397

YBN-R/3 Analogue mounting base (ivory and white)YBO-R/SCI Isolator base

Detectors:

ROD-E Wireless optical smoke detectorRMD-E Wireless multi-criteria detectorRHD-E Wireless heat detector

Horing LIH Industrial Co LtdNo. 17-6, Ai-Chien Road, Hu-Hsi Village, Yuan-Shan Hsiang (264), Ilan Hsien, Taiwan ROCTel: +886 2 22487599 • Fax: +886 2 22407752

Certificate No: 506e to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

AH-0218 Conventional fire alarm bell 506e/01AH-03127S Conventional Type B electronic sounder (AH-03127MB Base) 506e/02

Note: Meets the requirements of EN54-3: 2001 at the following tones:1-Alternating Tones 800/970Hz at 2Hz2-Sweeping 800/970Hz at 7Hz

AH-03127-BS Conventional Type B electronic sounder beacon (AH-03127MB Base) 506e/03Notes: 1. Meets the requirements of EN54-3: 2001 at the following tones:1-Alternating Tones 800/970Hz at 2Hz2-Sweeping 800/970Hz at 7Hz

2. The beacon functionality is not included within the scope of approval.

Base:

AH-03127MB

Hosiden Besson LimitedSt Joseph's Close Trading Estate, St Joseph's Close, Hove, East Sussex BN3 7EZ, United KingdomTel: +44 (0)1273 860000 • Fax: +44 (0)1273 777501E-mail: [email protected] • Website: www.hbl.co.uk

Certificate No: 715a-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

Wafer MT Conventional 32 Tone Sounder 715a/04Notes:1) Suitable for Type A indoor application only2) Approved at 12 & 24 VDC3) Approved with body moulding colour variations4) To be used in conjunction with a suitable detector when supplied without cover5) Meets requirements of EN 54-3: 2001 with the following tones:Sound 2 Banshee LF Fast Sweep - 800Hz - 950Hz Swept @ 9HzSound 13 Banshee / Bedlam HF Fast Sweep - 2400Hz - 2900Hz @ 9HzSound 15 Banshee / Bedlam HF Continuous - Continuous 2900Hz @ 3HzSound 19 Slow Whoop (Dutch) - 500Hz - 1200Hz over 3.5s then silence for 0.5s repeatSound 20 DIN Tone (DK) - 1200Hz - 500Hz over 1s, silence 10ms repeatSound 21 French Fire Sound - 554Hz for 100ms & 440Hz for 400ms

FM Bedroom Conventional 2 tone sounder 715a/06Notes:1) Suitable for Type A indoor application only2) Approved with body moulding colour variations

Page 408: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

398 31 Dec 2012

Certificated Products LPCB Ref. No.

3) Meets requirements of EN 54-3: 2001 with the following tones:Sound 1 Continuous 850 HzSound 2 Fast Sweep 800 - 950 Hz @ 9 Hz

Bases:Shallow base (various colour options)Deep base (various colour options)

KAC Alarm Company LimitedKAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United KingdomTel: +44 (0)1527 406655 • Fax: +44 (0)1527 406677E-mail: [email protected] OR [email protected] • Website: www.kac.co.uk

Certificate No: 166c to EN 54-3: 2001 + A1: 2002 + A2: 2006Certificate No: 166d to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

EMA1224B4R 4 Tone wall mounting conventional sounder, red. 166c/01Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

EMA1224B4W 4 Tone wall mounting conventional sounder, white 166c/02Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

SOU-SSR-4 4 Tone surface mounting conventional sounder with sealing kit, red 166c/03Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

SOU-SSW-4 4 Tone surface mounting conventional sounder with sealing kit, white 166c/04Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

SOU-LPR-4 4 Tone low profile mounting conventional sounder, red 166c/05Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

SOU-LPW-4 4 Tone low profile mounting conventional sounder, white. 166c/06Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

SOU-SR-4 4 Tone surface mounting conventional sounder, red. 166c/07Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

SOU-SW-4 4 Tone surface mounting conventional sounder, white. 166c/08Note: Meets the requirements of EN 54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

WMSST-xx-Pww Intelligent wall mounted sounder strobe 166c/09Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol2. X x indicates body colour. R =Red, W =Bright White, P =Pure White3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear4. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32 VDC

WMSOU-xx-Pww Intelligent wall mounted sounder 166c/10Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol2. xx indicates body colour. RR =Red, WW =Bright White, PW =Pure White3. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32 VDC

IBSST-xx-Pww Intelligent integrated detector base sounder strobe 166c/11Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol2. X x indicates body colour. R =Red, W =Bright White, D =Detector White, K =Black, P =Pure White3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear4. Meets the requirements of EN54-3 for all tones at voltage range 15-32 VDC with the

Page 409: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 399

Certificated Products LPCB Ref. No.

exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only

IBSOU-xx-Pww Intelligent integrated detector base sounder 166c/12Notes: 1. ww (Range 0-99 odd numbers only) indicates the communication software protocol2. xx indicates body colour. RR =Red, WW =Bright White, DD =Detector White, KK =Black, PW =Pure White3. Meets the requirements of EN54-3 for all tones at voltage range15-32 VDC with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only

EMA1224FR Conventional Type A wall mounted sounder (red) 166c/15Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

EMA1224FW Conventional Type A wall mounted sounder (white) 166c/16Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

DBS-4 Conventional Type A sounder base (white) 166c/27Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

DBS-R-4 Conventional Type A sounder base (white), supplied with red lid 166c/28Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

DBS-W-4 Conventional Type A sounder base (white), supplied with white lid 166c/29Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

DBS1224B4W Conventional Type A wall mounted sounder 166c/30Note: Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC and 21-27 VDC

WMSST-xx-Pww Intelligent wall mounted sounder strobe with short circuit isolator 166d/01Notes: 1. ww (Range 0-99 even numbers only indicates the ommunication software protocol2. X x indicates body colour. R =Red, W =Bright White, P =Pure White3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear4. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-28v

WMSOU-xx-Pww Intelligent wall mounted sounder with short circuit isolator 166d/02Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol2. xx indicates body colour. RR =Red, WW =Bright White, PW =Pure White 3. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-28v

IBSST-xx-Pww Intelligent integrated detector base sounder strobe with short circuit isolator 166d/03Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol2. X x indicates body colour. R =Red, W =Bright White, D =Detector White, K=Black, P =Pure White3. x X indicates lens colour. R =Red, A =Amber, G =Green, B =Blue, C =Clear4. Meets the requirements of EN54-3 for all tones at voltage range 15-28v with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only

IBSOU-xx-Pww Intelligent integrated detector base sounder with short circuit isolator 166d/04Notes: 1. ww (Range 0-99 even numbers only) indicates the communication software protocol2. xx indicates body colour. RR =Red, WW =Bright White, DD =Detector White, KK=Black, PW =Pure White 3. Meets the requirements of EN54-3 for all tones at voltage range 15-28v with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only

EMA12Fxxxx Conventional Type A wall mounted sounder strobe (ELPBR/W, ESBR/W and ESBRS/WS bases)

166c/31

Notes:1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC2) XX xx indicates body colour. RS =Red, WS =White 3) xx XX indicates lens colour. SR =Red, SA =Amber, SC =Clear

EMA24Fxxxx Conventional Type A wall mounted sounder strobe (ELPBR/W, ESBR/W and ESBRS/WS bases)

166c/32

Notes:1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 21-27 VDC

Page 410: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

400 31 Dec 2012

Certificated Products LPCB Ref. No.

2) XX xx indicates body colour. RS =Red, WS =White3) xx XX indicates lens colour. S -=Red and Amber supplied, SR =Red, SA =Amber, SB =Blue

SST-xxWx-14 Conventional Type A wall mounted sounder strobe (white) (ELPBR/W, ESBR/W and ESBRS/WS bases)

166c/33

Notes:1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14 VDC 2) XX Wx indicates base type. LP =ELPBR/W, - S =ESBR/W, SS =ESBRS/WS.3) xxW X indicates lens colour. R =Red, A =Amber, B =Blue, G =Green

SST-xxRx-14 Conventional Type A wall mounted sounder strobe (red) (ELPBR/W, ESBR/W and ESBRS/WS bases)

166c/34

Notes:1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 21-27 VDC 2) XX Rx indicates base type. LP =ELPBR/W, - S =ESBR/W, SS =ESBRS/WS.3) xxR X indicates lens colour. R =Red, A =Amber, B =Blue

WMSST-RR-P30 Intelligent wall mounted sounder strobe with short circuit isolator. 166d/07Note: 1. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-28v

WMSST-RR-P29 Intelligent wall mounted sounder strobe. 166c/35Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32 VDC

IBSST-DR-P29 Intelligent integrated detector base sounder strobe 166c/36Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32 VDC with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only.

IBSST-DR-P30 Intelligent integrated detector base sounder strobe with short circuit isolator 166d/08

Note:1. Meets the requirements of EN54-3 for all tones at voltage range 15-28v with the exception of Tones 4,10,11,17 and 20, which are approved at maximum volume only

EMA1224B4R-D 4 Tone Type A conventional wall mounting sounder, red 166c/37Note:

Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop

4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence

EMA1224B4W-D 4 Tone Type A conventional wall mounting sounder, white 166c/38Note:

Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop

4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence

DBS1224B4W-D 4 Tone Type A conventional ceiling mounting sounder, white 166c/40Note:

Meets the requirements of EN 54-3 at all output levels, and voltage ranges of 10-14 VDC and 19.5-28 VDC for the following tones: 1 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence 2 - 800Hz continuous 3 - 500Hz-1200Hz slow whoop 4 - Falling 1200Hz-500Hz over 3.5s followed by 0.5s silence

EMA12BxSSy 4 Tone Conventional 12 VDC Type A wall mounted sounder/strobe(ELPBR/W, ESBR/W and ESBRS/WS bases)

Notes:Meets the requirements of EN54-3 for output levels at voltage range 10-14VDC the following tones: 1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz - 1200Hz slow whoop

166c/41

Page 411: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 401

Certificated Products LPCB Ref. No.

4. 800Hz DIN tone

x indicates body colour. R =Red, W =White y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red

EMA24BxSSy 4 Tone Conventional 24 VDC Type A wall mounted sounder/strobe(ELPBR/W, ESBR/W and ESBRS/WS bases)

Notes:Meets the requirements of EN54-3 for output levels at voltage range 21-27VDC for the following tones: 1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz - 1200Hz slow whoop4. 800Hz DIN tone

x indicates body colour. R =Red, W =White y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red, T =Red and Amber supplied

166c/42

EMA12BxSSy-D 4 Tone Conventional 24 VDC Type A wall mounted sounder/strobe(ELPBR/W, ESBR/W and ESBRS/WS bases)

Notes:Meets the requirements of EN54-3 for output levels at voltage range 21-27VDC for the following tones:1. 1200Hz - 500Hz DIN tone2. 800 Hz Continuous3. 500Hz - 1200Hz slow whoop4. 1200Hz - 500Hz DIN tone

x indicates body colour. R =Red, W =White y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red

166c/44

SST-LPRy-4 4 Tone Conventional 24 VDC Type A wall mounted Red sounder/strobe (ELPBR, ESBR and ESBRS bases)

Notes: Meets the requirements of EN54-3 for output levels at voltage range 21-27VDC for the following tones:1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz - 1200Hz slow whoop4. 800Hz DIN tone

y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red

166c/45

SST-LPWy-4 4 Tone Conventional 12 VDC Type A wall mounted White sounder/strobe (ELPBW, ESBW and ESBWS bases)

Notes: Meets the requirements of EN54-3 for output levels at voltage range 10-14VDC for the following tones:1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz 1200Hz slow whoop4. 800Hz DIN tone

y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red

166c/46

SST-SRy-4 4 Tone Conventional 24 VDC Type A wall mounted Red sounder/strobe (ELPBR, ESBR and ESBRS bases)

Notes: Meets the requirements of EN54-3 for output levels at voltage range 21-27VDC for the following tones:1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz - 1200Hz slow whoop4. 800Hz DIN tone

y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red

166c/47

SST-SWy-4 4 Tone Conventional 12 VDC Type A wall mounted White sounder/strobe (ELPBW, ESBW and ESBWS bases)

Notes: Meets the requirements of EN54-3 for output levels at voltage range 10-14VDC

166c/48

Page 412: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

402 31 Dec 2012

Certificated Products LPCB Ref. No.

for the following tones:1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz - 1200Hz slow whoop4. 800Hz DIN tone

y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =RedSST-SSRy-4 4 Tone Conventional 24 VDC Type A wall mounted Red sounder/strobe

(ELPBR, ESBR and ESBRS bases)

Notes: Meets the requirements of EN54-3 for output levels at voltage range 21-27VDCfor the following tones:1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz - 1200Hz slow whoop4. 800Hz DIN tone

y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red

166c/49

SST-SSWy-4 4 Tone Conventional 12 VDC Type A wall mounted White sounder/strobe (ELPBW, ESBW and ESBWS bases)

Notes: Meets the requirements of EN54-3 for output levels at voltage range 10-14VDC for the following tones:1. 800 Hz Continuous2. 800Hz /1000Hz Alternating3. 500Hz - 1200Hz slow whoop4. 800Hz DIN tone

y indicates lens colour. A =Amber, B =Blue, C =Clear , G =Green, R =Red

166c/50

Bases:ELPBR/W Low profile base IP21C, red or whiteESBR/W Standard base IP54, red or whiteESBRS/WS Standard base and IP66 sealing kit, red or white

Labor Strauss Sicherungsanlagenbau GmbHWiegelestrasse 36, A-1231 Vienna, AustriaTel: +43 1 52114-44 • Fax: +43 1 52114-27E-mail: [email protected] • Website: www.lst.at

Certificate No: 546a-(cl-3) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.200/FBRI/SOUW Conventional indoor Type A sounder base 546a/04

Notes:1. Also approved in Off-white, Ivory and Alternative white (-O, -I, and -A suffixes)2. Meets the requirements of EN 54-3 at the following tone settings on low, medium and high volume settings:

1 - LF Sweep (Cranford sweep) (800-1000Hz @ 0.5 Sec) 3 - Alternative Warble (800-1000Hz @ 0.5 Sec) 11 - Dutch Sweep Tone (970Hz Cont) 25 - German DIN Tone (Sweep 1200-500Hz @ 1Hz) 27- French Tone AFNOR (554Hz 100ms and 440Hz for 400 ms)

3. Cover plate (Part No. 116-099) must be used.

Page 413: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 403

Morley-IAS Fire Systems by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UFTel: +44 (0)1444 235556 • Fax: +44 (0)1444 254410E-mail: [email protected] • Website: www.morley-ias.co.uk

Certificate No: 166c to EN 54-3: 2001Certificate No: 166d to EN 54-3: 2001 and CEA GEI 1-052 Draft 2.0: 11.06.97Certificate No: 166h-(cl-3) to EN 54-3: 2001 + A1: 2002 + A2: 2006Certificate No: 166j-(cl-3) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

MI-WSDB-X-XX Intelligent wall mounted sounder strobe 166c/09Notes:1) x-xx indicates body colour. R=Red, W=Detector White2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear

MI-WSD-X Intelligent wall mounted sounder 166c/10Note:1) x indicates body colour. R=Red, W=Detector White

MI-IBSDB-X-XX Intelligent integrated detector base sounder strobe 166c/11Notes:1) x-xx indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear

MI-IBSD-X Intelligent integrated detector base sounder 166c/12Note:1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black

MI-WSDB-X-XX-I Intelligent wall mounted sounder strobe with short circuit isolator 166d/01Notes:1) x-xx indicates body colour. R=Red, W=Detector White2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear

MI-WSD-X-1 Intelligent wall mounted sounder with short circuit isolator 166d/02Note:1) x indicates body colour. R=Red, W=Detector White

MI-IBSDB-X-XX-I Intelligent integrated detector base sounder strobe with short circuit isolator 166d/03Notes:1) x-xx indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black 2) x-xx indicate lens colour. RD=Red, AM=Amber, GR=Green, BL=Blue, CL=Clear

MI-IBSD-X-I Intelligent integrated detector base sounder with short circuit 166d/04Note:1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black

MI-WSO-xx-N Analogue addressableType A/B wall mounted sounder(B501AP-cc, Bcc bases, and Wcc bases)

166h/01

Notes: 1. xx indicates body colour. PR =Red, PP =Pure White2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz;

Page 414: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

404 31 Dec 2012

Certificated Products LPCB Ref. No.

30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Approved as Type B only when used with Wcc base.MI-WSS-xx-N Analogue addressable Type A/B wall mounted sounder/strobe

(B501AP-cc, Bcc, and Wcc bases)166h/02

Notes: 1. xx indicates body/lens colour. PR =Red/Red, PA =Amber/Amber, PC =Clear/Clear2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function. 5. Approved as Type B only when used with Wcc base.

MI-BSO-xx-N Analogue addressable Type A integrated detector base sounder(B501AP-cc, Bcc and Wcc bases)

166h/03

Notes: 1. xx indicates body colour. PP =Pure White, DD =Detector White2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

MI-BSS-xx-N Analogue addressable Type A integrated detector base sounder/strobe(B501AP-cc, Bcc and Wcc bases)

166h/04

Notes: 1. xx indicates body/lens colour. PR =Pure White/Red,

PA =Pure White/Amber, PC =Pure White/Clear, DR =Detector White/Red, DA =Detector White/Amber, DC =Detector White/Clear

2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC

Page 415: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 405

Certificated Products LPCB Ref. No.

and tones:1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function.MI-WSO-xx-I Analogue addressableType A/B wall mounted sounder with short circuit isolator

(B501AP-cc, Bcc bases, and Wcc bases)166j/01

Notes: 1. xx indicates body colour. PR =Red, PP =Pure White2. yy indicates customer and associated communication protocol.01 indicates Advanced Protocol (and Honeywell 500 series protocol)00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Approved as Type B only when used with Wcc base.MI-WSS-xx-I Analogue addressable Type A/B wall mounted sounder/strobe with short circuit isolator

(B501AP-cc, Bcc bases, and Wcc bases)166j/02

Notes: 1. xx indicates body/lens colour. PR =Red/Red, PA =Amber/Amber, PC =Clear/Clear2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz;

Page 416: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

406 31 Dec 2012

Certificated Products LPCB Ref. No.

27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function. 5. Approved as Type B only when used with Wcc base.

MI-BSO-xx-I Analogue addressable Type A integrated detector base sounder with short circuit isolator (B501AP-cc, Bcc and Wcc bases)

166j/03

Notes: 1. xx indicates body colour. PP =Pure White, DD =Detector White2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

MI-BSS-xx-I Analogue addressable Type A integrated detector base sounder/strobe with short circuit isolator (B501AP-cc, Bcc and Wcc bases)

166j/04

Notes: 1. xx indicates body/lens colour. PR =Pure White/Red,

PA =Pure White/Amber, PC =Pure White/Clear, DR =Detector White/Red, DA =Detector White/Amber, DC =Detector White/Clear

2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function.

Bases

B501AP-cc Low profile base IP21C, cc indicates colour, Blank=Pure White, IV=Detector WhiteBcc Deep base IP44, cc indicates colour, RR=Red, DD=Detector White, PW=Pure WhiteWcc Waterproof base IP65, cc indicates colour, RR=Red, DD=Detector White, PW=Pure White

Page 417: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 407

Multron Systems Pte Ltd217 Kallang Bahru, Multron Building, Singapore 339 347, SingaporeTel: +65 6743 2555 / 6395 6868 • Fax: +65 6743 2777 / 6395 6869E-mail: [email protected] • Website: www.multron.com

Certificate No: 548e-(cl-6) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.AVD-C403 Conventional sounder strobe (Shallow and Deep Bases) 548e/01

Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval.

AVD-A403 Intelligent sounder strobe (Shallow and Deep Bases) 548e/02Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off Pre Alarm 800Hz, 1s on / 1s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval 4. Approved with single address and dual address (pre-alarm and main alarm).

BasesShallow BaseDeep base

Nitin Ventures FZEP.O. Box 262294, Jebel Ali Free Zone, Dubai, United Arab EmiratesTel: +97 148865858/859 • Fax: +97 148865800E-mail: [email protected] • Website: www.nitinventures.com

Certificate No: 010ak-(cl-2) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

NV-IA-SND XP95 Type B intelligent open area sounder (Red) (NV-IAI-DIB base) 010ak/01Note:1. Meets the requirements of EN 54-3:2001 at the following tones:

Apollo standard - 840Hz, 0.5s / 558Hz, 0.5s Dutch (slow whoop) - 500-1200Hz in 3.5s, 0.5s off German DIN - 1200-500Hz over 1s

NV-IA-SBR XP95 Type B intelligent open area sounder beacon (Red) (NV-IAI-BID) 010ak/03Note:1. Meets the requirements of EN 54-3:2001 at the following tones:

Apollo standard - 840Hz, 0.5s / 558Hz, 0.5s Dutch (slow whoop) - 500-1200Hz in 3.5s, 0.5s off German DIN - 1200-500Hz over 1s

Bases:

NV-IAI-DIB Enhanced deep isolating base (Red)

Page 418: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

408 31 Dec 2012

Notifier by Honeywell (Pittway Systems Technology Group (Europe) Ltd)Charles Avenue, Burgess Hill, West Sussex RH15 9UF, United KingdomTel: +44 (0)1444 230230 • Fax: +44 (0)1444 230689E-mail: [email protected] • Website: www.notifierfiresystems.co.uk

Certificate No: 166c to EN 54-3: 2001 + A1: 2002 + A2: 2006Certificate No: 166d to EN 54-3: 2001 and CEA GEI 1-052 Draft 2.0: 11.06.97Certificate No: 166j-(cl-2) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

AWSB32/X/X Intelligent wall mounted sounder strobe 166c/09Notes:1) x/x indicates body colour. R=Red, W=Detector White2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear

AWS32/X Intelligent wall mounted sounder 166c/10Note:1) x indicates body colour. R=Red, W=Detector White

ABSB32/X/X Intelligent integrated detector base sounder strobe 166c/11Notes:1) x/x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear

ABS32/X Intelligent integrated detector base sounder 166c/12Note:1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black

AWSB32/X/X-I Intelligent wall mounted sounder strobe with short circuit isolator 166d/01Notes:1) x/x indicates body colour. R=Red, W=Detector White2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear

AWS32/X-I Intelligent wall mounted sounder with short circuit isolator 166d/02Note:1) x indicates body colour. R=Red, W=Detector White

ABSB32/X/X-I Intelligent integrated detector base sounder strobe with short circuit isolator 166d/03Notes:1) x/x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black2) x/x indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=Clear

ABS32/X-I Intelligent integrated detector base sounder with short circuit isolator 166d/04Note:1) x indicates body colour. R=Red, W=Detector White, PW=Pure White, B=Black

NS4/R 4 Tone wall mounting conventional sounder (red) 166c/01Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v

NS4/R/W 4 Tone wall mounting conventional sounder (white) 166c/02Note: 1) Meets the requirements of EN54-3 for all tones and output levels at voltage ranges 10-14v and 21-27v

NFXI-WS-z Analogue addressableType A/B wall mounted sounder with short circuit isolator(B501AP-cc, Bcc bases, and Wcc bases)

166j/01

Notes: 1. z indicates body colour. R =Red, W =Pure White2 Advanced Protocol (and System Sensor 500 series protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on);

Page 419: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 409

Certificated Products LPCB Ref. No.

25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Approved as Type B only when used with Wcc base.NFXI-WSF-zz Analogue addressable Type A/B wall mounted sounder/strobe with short circuit isolator

(B501AP-cc, Bcc bases, and Wcc bases)166j/02

Notes: 1. zz indicates body/lens colour. RR =Red/Red, WC =Clear/Clear2. Advanced Protocol (and System Sensor 500 series protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function. 5. Approved as Type B only when used with Wcc base.

NFXI-BS-zz Analogue addressable Type A integrated detector base sounder with short circuit isolator(B501AP-cc, Bcc and Wcc bases)

166j/03

Notes: 1. zz indicates body colour. W =Pure White, IV =Detector White2 Advanced Protocol (and System Sensor 500 series protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

NFXI-BSF-zzz Analogue addressable Type A integrated detector base sounder/strobe with short circuit isolator(B501AP-cc, Bcc and Wcc bases)

166j/04

Notes: 1. zzz indicates body/lens colour. WC =Pure White/Clear, IVC =Detector White/Clear2. Advanced Protocol (and System Sensor 500 series protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on;

Page 420: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

410 31 Dec 2012

Certificated Products LPCB Ref. No.

14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function.

Pelco Finland OyKalkkipellontie 6, 02650, Espoo, FinlandTel: +358 10 446 511 • Fax: +358 10 446 5103E-mail: [email protected] • Website: www.pelco.com/nordic

Certificate No: 010ak-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

ESI-52 Type B intelligent open-area sounder (red) (06728115 and 06728116 bases)

010ak/01

Note:1. Meets the requirements of EN 54-3:2001 at the following tones:

Apollo standard - 840Hz, 0.5s / 558Hz, 0.5s Dutch (slow whoop) - 500-1200Hz in 3.5s, 0.5s off German DIN - 1200-500Hz over 1s

ESI-53 Type B intelligent open-area sounder beacon (red)(06728115 and 06728116 bases)

010ak/03

Note:1. Meets the requirements of EN 54-3:2001 at the following tones:

Apollo standard - 840Hz, 0.5s / 558Hz, 0.5s Dutch (slow whoop) - 500-1200Hz in 3.5s, 0.5s off German DIN - 1200-500Hz over 1s

ESI-51 Analogue addressable Type B intelligent open area sounder beacon (Red) (06728116, 06728115 bases)

010ak/05

Note:Meets the requirements of EN 54-3:2001 at the following tones:T1- Apollo Evacuation 558Hz, 0.5 s / 840Hz, 0.5sT3- Dutch Slow Whoop 500-1200Hz in 3.5s, 0.5s off T4- German DIN1200 - 500Hz over 1s

Bases:06728115 Enhanced deep isolating base (white)06728116 Enhanced deep isolating base (red)

Protec Fire Detection plcProtec House, Churchill Way, Nelson, Lancashire BB9 6RT, United KingdomTel: +44 (0)1282 717171 • Fax: +44 (0)1282 717273E-mail: [email protected] • Website: www.protec.co.uk

Certificate No: 201n to EN 54-3: 2001

Certificated Products LPCB Ref. No.

6000/SSR2 Analogue addressable Type A/B sounder - red (Shallow and N29-982-75 base) 201n/01

Page 421: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 411

Certificated Products LPCB Ref. No.

Notes:1) The device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones:

1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz

6000/SSW2 Analogue addressable Type A/B sounder - white (Shallow and N29-982-75 base) 201n/02Notes:1) This device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones:

1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz

6000/SSR2/NL Analogue addressable Type A/B sounder - red (Shallow and N29-982-75 base) 201n/03Notes:1) This device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones:

1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz 3 - Dutch whoop - 500 / 1500 Hz

6000/SSW2/NL Analogue addressable Type A/B sounder - white (Shallow and N29-982-75 base) 201n/04Notes:1) This device is supplied with a shallow base. 2) Meets the requirements of EN 54-3: 2001 with the following tones:

1 - Continuous tone - 990 Hz 2 - Warble tone - 990 / 695 Hz 3 - Dutch whoop - 500 / 1500 Hz

Bases:N29-982-75 Deep baseShallow base

SHIELD FIRE, SAFETY AND SECURITY LTD29th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United KingdomTel: +44 207 712 1610 • Fax: +44 207 712 1578E-mail: [email protected] • Website: www.shieldglobal.com

Certificate No: 548e-(cl-4) to EN 54-3: 2001 + A1: 2002 + A2: 2006

Audible Warning DevicesCertificated Products LPCB Ref.

No.S-A491 Intelligent sounder strobe (Shallow and Deep Bases) 548e/02

Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off Pre Alarm 800Hz, 1s on / 1s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval 4. Approved with single address and dual address (pre-alarm and main alarm).

S-C481 Conventional sounder strobe (Shallow and Deep Bases) 548e/01Notes: 1. Meets the requirements of EN 54-3: 2001 at the following tones: Tone 14 2400Hz - 2900Hz @ 3Hz Tone 16 500HZ - 1200Hz, 3.75s on / 0.25s off 2. Approved in both normal and power saving mode3. The visual alarm function is not in the scope of this approval.

BasesShallow BaseDeep base

Page 422: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

412 31 Dec 2012

Siemens Switzerland Limited, Building Technologies DivisionInternational Headquarters, Gubelstrasse 22, CH-6301 Zug, SwitzerlandTel: +41 (0) 41 724 24 24 • Fax: +41 (0) 41 724 35 22

Certificate No: 126ar-(cl-1) to EN54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

SoundersCertificated Products LPCB Ref.

No.FDS229-R Analogue addressable sounder beacon (Red) with short circuit isolator 126ar/01

(FDB221, FDB221-AA, FDB291 and FDB293) 1) Meets the requirements of EN 54-3 at the following tones:

Continuous 970Hz 1s Intermittent 950Hz 1s Sweep-down 1200Hz-500Hz 3.5s Slow-whoop sweep-up, 0.5s linear 500Hz-1200Hz Pulse-tone 150ms on 100ms off 500Hz Intermittent 150ms on 600ms off 500Hz Continuous 500Hz Alternating 0.1s on 0.4s off 560Hz/440Hz Intermittent 600ms on 650ms off 420Hz 3.75s Slow-whoop sweep-up, 0.25s linear 500Hz-1200Hz Intermittent 0.5s on 0.5s off 1s pause 970Hz

FDS229-A Analogue addressable sounder beacon (Amber) with short circuit isolator 126ar/02 (FDB221, FDB221-AA, FDB291 and FDB293)

1) Meets the requirements of EN 54-3 at the following tones: Continuous 970Hz

1s Intermittent 950Hz 1s Sweep-down 1200Hz-500Hz 3.5s Slow-whoop sweep-up, 0.5s linear 500Hz-1200Hz Pulse-tone 150ms on 100ms off 500Hz Intermittent 150ms on 600ms off 500Hz Continuous 500Hz Alternating 0.1s on 0.4s off 560Hz/440Hz Intermittent 600ms on 650ms off 420Hz 3.75s Slow-whoop sweep-up, 0.25s linear 500Hz-1200Hz Intermittent 0.5s on 0.5s off 1s pause 970Hz

FDS221-x Analogue addressable loop sounder with short circuit isolator(FDB221, FDB221-AA, FDB222, FDB291 and FDB293 bases)

126ar/03

Notes:1. Key, x = R Body colour Red x = W Body colour White 2. Meets the requirements of EN 54-3 at the following tones:

970Hz Continuous 950Hz 1s Intermittent 1200-500Hz Sweep Down 1s 520-1200Hz Sweep Up 3.5s, 0.5s off 500Hz Pulse 0.15s on, 0.1s off 500Hz Pulse 0.15s on, 0.6s off 500Hz Continuous 560Hz/440Hz 100ms on, 400ms off 420Hz 0.6s on, 0.65s off 500Hz-1200Hz Sweep Up 3.75s, 0.25s off 970Hz 3 pulses 0.5s on 0.5s off, then 1.5s pause

Accessories:

FDB221 Detector baseFDB221-AA Detector base, addressed with 2 micro-terminalsFDB291 Base attachment FDB293 Base attachment wetFDB221/FDB221-AA Analogue addressable base FDB222 Flat, Analogue addressable baseFDB291 Base attachmentFDB293 Base attachment humid

Page 423: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 413

SMS (Novar Systems Ltd)Hamilton Industrial Park, 140 Waterside Road, Leicester LE5 1TN, United KingdomTel: +44 (0)116 246 2100 • Fax: +44 (0)116 246 2016Website: www.smsfire.co.uk

Certificate No: 042bk to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

CONV-SN-R Conventional Red LP Indoor Sounder 042bk/01Note:1. Meets the requirements of EN 54-3:2001 at Tones:

1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

CONV-IP-SN-R Conventional Red LP Outdoor Sounder 042bk/03Note:1. Meets the requirements of EN 54-3:2001 at Tones:

1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

CONV-SN-ST-RR Conventional Red LP Indoor Sounder/Strobe Red Lens 042bk/05Notes: 1. Meets the requirements of EN 54-3:2001 at Tones:

1. Alternating tone 800/970 Hz @ 2Hz. 3. Intermittent tone 970 Hz @ 1Hz. 6. Continuous 970 Hz.

2. Certification excludes Strobe function

Sterling Safety SystemsUnit B12a, Holly Farm Business Park, Honiley, Warwickshire CV8 1NP, United KingdomTel: +44(0)1926485282 • Fax: +44(0)1926485090E-mail: [email protected] • Website: www.sterlingsafety.co.uk

Certificate No: 928g to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005Certificate No: 928q-(cl-5) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-25: 2008

Certificated Products LPCB Ref. No.

HFI-WSR-01 Analogue addressable Type A sounder with short circuit isolator 928g/01Notes:1. Meets the requirements of EN 54-3 at the following tone settings:

Dual tone 990 to 650Hz, 2Hz (250ms-250ms) Pulsed tone 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone 990Hz, steady

HFW-BS-01 Wireless type A sounder base 928q/01Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with HFW-PA-01, HFW-MA-01 and HFW-TA-01 wireless detectors

3. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

HFW-BSB-01 Wireless type A audiovisual sounder base 928q/02Notes:1. Meets the requirements of EN54-3 at the following tones:-

Page 424: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

414 31 Dec 2012

Certificated Products LPCB Ref. No.

1. Continuous 970Hz2. Warble 800/1000/1Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. Approved for use with HFW-PA-01, HFW-MA-01 and HFW-TA-01 wireless detectors

3. The Visual Warning part is not approved to EN 54-234. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

HFW-WSR-01 Wireless type A wall sounder 928q/03Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

HFW-SBR-01 Wireless type A audiovisual wall sounder 928q/04Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

HFW-WSR-02 Wireless type A Dutch tone wall sounder 928q/05Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

HFW-WSW-01 Wireless type A wall sounder white colour 928q/06Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

HFW-SBW-01 Wireless type A audiovisual wall sounder white colour 928q/07Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Dual tone 990/650/2Hz3. Slow whoop 500-1200Hz4. Sweep (DIN) 1200-500Hz

2. The Visual Warning part is not approved to EN 54-233. The device must be used with the following batteries only:

CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

HFW-WSW-02 Wireless type A Dutch tone wall sounder white colour 928q/08Notes:1. Meets the requirements of EN54-3 at the following tones:-

1. Continuous 990Hz2. Slow whoop 500-1200Hz3. Sweep (DIN) 1200-500Hz

2. The device must be used with the following batteries only:CR123A (3 Vdc) - main batteryCR123A (3 Vdc) - secondary battery

Page 425: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 415

Certificated Products LPCB Ref. No.

Detectors:

HFW-PA-01 Wireless optical smoke detectorHFW-MA-01 Wireless multi-criteria detectorHFW-TA-01 Wireless heat detector

System Sensor EuropeKAC House, Thornhill Road, North Moons Moat, Redditch, Worcestershire B98 9ND, United KingdomTel: +44 (0)1527 406700 • Fax: +44 (0)1527 406699Website: www.systemsensoreurope.com

Certificate No: 166c to EN 54-3: 2001 + A1: 2002 + A2: 2006Certificate No: 166d to EN 54-3 + A1: 2002 + A2: 2006 and EN 54-17:2005

Certificated Products LPCB Ref. No.

WMSST-XX-P01 Intelligent wall mounted sounder strobe 166c/09Notes:1) xx indicates body colour. R=Red, W=Bright White2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=ClearMeets the requirements of EN54-3 for all tones and output levels at voltage range 15-32v.

WMSOU-XX-P01 Intelligent wall mounted sounder 166c/10Note:1) xx indicates body colour. RR=Red, WW=Bright WhiteMeets the requirements of EN54-3 for all tones and output levels at voltage range 15-32v.

IBSST-XX-P01 Intelligent integrated detector base sounder strobe 166c/11Notes:1) xx indicates body colour. R=Red, W=Bright White, D=Detector White, K=Black2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=ClearMeets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only.

IBSOU-XX-P01 Intelligent integrated detector base sounder 166c/12Note:1) xx indicates body colour. RR=Red, WW=Bright White, DD=Detector White, KK=Black

WMSST-XX-P02 Intelligent wall mounted sounder strobe with short circuit isolator 166d/01Notes:1) xx indicates body colour. R=Red, W=Bright White2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=ClearMeets the requirements of EN54-3 for all tones and output levels at voltage range 15-32v.

WMSOU-XX-P02 Intelligent wall mounted sounder with short circuit isolator 166d/02Note:1) xx indicates body colour. RR=Red, WW=Bright White. Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32v.

IBSST-XX-P02 Intelligent integrated detector base sounder strobe with short circuit isolator 166d/03Notes:1) xx indicates body colour. R=Red, W=Bright White, D=Detector White, K=Black2) xx indicates lens colour. R=Red, A=Amber, G=Green, B=Blue, C=ClearMeets the requirements of EN-54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only.

IBSOU-XX-P02 Intelligent integrated detector base sounder with short circuit isolator 166d/04Note:1) xx indicates body colour. RR=Red, WW=Bright White, DD=Detector White, KK=BlackMeets the requirements of EN-54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only.

WMSST-RR-P30 Intelligent wall mounted sounder strobe 166d/07Note:1) Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-28v.

IBSST-DR-P30 Intelligent integrated detector base sounder strobe. 166d/08Notes:

Page 426: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

416 31 Dec 2012

Certificated Products LPCB Ref. No.

1) Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20, which are approved at maximum volume only.

WMSST-RR-P29 Intelligent wall mounted sounder strobe 166c/35Meets the requirements of EN54-3 for all tones and output levels at voltage range 15-32v.

IBSST-DR-P29 Intelligent integrated detector base sounder strobe. 166c/36Meets the requirements of EN54-3 for all tones at voltage range 15-32v with the exception of Tones 4, 10, 11, 17 and 20 which are approved at maximum volume only.

System Sensor Europe, Life Safety Distribution AGWeiherallee 11a, 8610, Uster, SwitzerlandTel: +41 44 943 4424 • Fax: +41 44 943 4399E-mail: [email protected] • Website: www.systemsensoreurope.com

Certificate No: 166h-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006Certificate No: 166j-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Audible Warning DevicesCertificated Products LPCB Ref.

No.WSO-xx-Nyy Analogue addressable Type A/B wall mounted sounder

(B501AP-cc, Bcc, Wcc bases)166h/01

Notes: 1. xx indicates body colour. PR =Red, PP =Pure White2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Approved as Type B only when used with Wcc base.WSS-xx-Nyy Analogue addressable Type A/B wall mounted sounder/strobe

(B501AP-cc, Bcc, Wcc bases)166h/02

Notes: 1. xx indicates body/lens colour. PR =Red/Red, PA =Amber/Amber, PC =Clear/Clear2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on;

Page 427: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 417

Certificated Products LPCB Ref. No.

14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function. 5. Approved as Type B only when used with Wcc base.

BSO-xx-Nyy Analogue addressable Type A integrated detector base sounder(B501AP-cc, Bcc and Wcc bases)

166h/03

Notes: 1. xx indicates body colour. PP =Pure White, DD =Detector White2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

BSS-xx-Nyy Analogue addressable Type A integrated detector base sounder/strobe(B501AP-cc, Bcc and Wcc bases)

166h/04

Notes: 1. xx indicates body/lens colour. PR =Pure White/Red,

PA =Pure White/Amber, PC =Pure White/Clear, DR =Detector White/Red, DA =Detector White/Amber, DC =Detector White/Clear

2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-32VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

Page 428: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

418 31 Dec 2012

Certificated Products LPCB Ref. No.

4. Certification excludes the strobe function.WSO-xx-Iyy Analogue addressableType A/B wall mounted sounder with short circuit isolator

(B501AP-cc, Bcc bases, and Wcc bases)166j/01

Notes: 1. xx indicates body colour. PR =Red, PP =Pure White2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Approved as Type B only when used with Wcc base.WSS-xx-Iyy Analogue addressable Type A/B wall mounted sounder/strobe with short circuit isolator

(B501AP-cc, Bcc bases, and Wcc bases)166j/02

Notes: 1. xx indicates body/lens colour. PR =Red/Red, PA =Amber/Amber, PC =Clear/Clear2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function. 5. Approved as Type B only when used with Wcc base.

BSO-xx-Iyy Analogue addressable Type A integrated detector base sounder with short circuit isolator (B501AP-cc, Bcc and Wcc bases)

166j/03

Notes: 1. xx indicates body colour. PP =Pure White, DD =Detector White2. yy indicates customer and associated communication protocol.

01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz;

Page 429: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 419

Certificated Products LPCB Ref. No.

7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

BSS-xx-Iyy Analogue addressable Type A integrated detector base sounder/strobe with short circuit isolator (B501AP-cc, Bcc and Wcc bases)

166j/04

Notes: 1. xx indicates body/lens colour. PR =Pure White/Red,

PA =Pure White/Amber, PC =Pure White/Clear, DR =Detector White/Red, DA =Detector White/Amber, DC =Detector White/Clear

2. yy indicates customer and associated communication protocol. 01 indicates Advanced Protocol (and Honeywell 500 series protocol) 00 and 02-99 indicates Advanced Protocol (and System Sensor 500 series

protocol)3. Meets the requirements of EN54-3 for all output levels at voltage range 15-29VDC and tones:

1) 554/440, 2Hz (100ms/400ms); 2) 800/970, 1Hz; 3) 800/970, 2Hz; 4) 2400/2900, 3Hz; 5) 2500/3100, 2Hz; 6) 988/645, 2Hz; 7) 660Hz; 8) 970Hz; 9) 1200Hz; 10) 2850Hz; 11) 150-1000, rise 10s, stable 40s, fall 10s, stable 20s, then repeating; 12) 420Hz, 0.625s on, 0.625 sec off; 13) 500-1200Hz, 0.25 sec off, 3.75 sec

on; 14) 660, 3.33Hz, 150ms on, 150ms off; 15) 970, 0.8Hz 0.25s on, 1s off; 16) 970, 0.5Hz 1s on, 1s off; 17) 2850, 1Hz; 18) 970, 1Hz 500ms on, 500ms off; 19) 950, 0.22Hz (0.5s on, 0.5s off) x 3, 1.5s off; 20) 800Hz; 21) 400-1200Hz, (0.5s on, 0.5s off) x 3, 1.5s off; 22) 1200 - 500Hz, 0.99Hz 1s on, 0.01s off; 23) 2400 - 2850, 7Hz; 24) 500 - 1200Hz, (0.5s off, 3.5s on); 25) 800 - 970, 50Hz; 26) 800 - 970, 7Hz; 27) 800 - 970, 1Hz; 28) 2400 - 2850, 50Hz; 29) 500 - 1000, 7Hz; 30) 500 - 1200 - 500, 0.166Hz rise 1s, stable 4s, fall 1s; 31) 800 - 1000, 2Hz; 32) 2400 - 2850, 1Hz.

4. Certification excludes the strobe function.

Bases

B501AP-cc Low profile base IP21C, cc indicates colour, Blank=Pure White, IV=Detector WhiteBcc Deep base IP44, cc indicates colour, RR=Red, DD=Detector White, PW=Pure WhiteWcc Waterproof base IP65, cc indicates colour, RR=Red, DD=Detector White, PW=Pure White

Teledata S.r.l.Via Giulietti 8, Milan 20132, ItalyTel: +39 02-27201352 • Fax: +39 02-2593704E-mail: [email protected] • Website: www.teledate-i.com

Certificate No: 928g-(cl-6) to EN 54-3: 2001 + A1: 2002 + A2: 2006 and EN 54-17: 2005

Certificated Products LPCB Ref. No.

FDS100 Analogue addressable Type A sounder with short circuit isolatorNotes:

928g/01

Page 430: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

420 31 Dec 2012

Certificated Products LPCB Ref. No.

1) Meets the requirements of EN 54-3 at the following tone settings: Dual tone: 990 and 650Hz, 2Hz (250ms-250ms) Pulsed tone: 990Hz, 1Hz (500ms ON - 500ms OFF) Continuous tone: 990Hz, steady

Texecom LtdBradwood Court, St Crispin Way, Haslingden, Lancashire BB4 4PW, United KingdomTel: +44 (0)1706 220460 • Fax: +44 (0)1706 230692E-mail: [email protected] • Website: http://www.texe.com

Certificate No: 717a to EN 54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

PSS-0068 Conventional Sounder with LED Strobe (Red Head / Red Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/01

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSS-0079 Conventional Sounder with LED Strobe (Red Head / White Base)PSO-0003 & PSO-0007 bases)

717a/02

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSS-0073 Conventional Sounder with LED Strobe (Amber Head / Red Base)PSO-0003 & PSO-0007 bases)

717a/03

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSS-0080 Conventional Sounder with LED Strobe (Amber Head / White Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/04

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSS-0084 Conventional Sounder (Red)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/05

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSS-0089 Conventional Sounder (White)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/06

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PBS-0003 Universal base sounder (White) 717a/07

Notes:1. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PBS-0009 Universal base sounder (Cream) 717a/08Notes:1. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

Page 431: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 421

Certificated Products LPCB Ref. No.

PSC-0045 Conventional Sounder with LED Strobe Common Operation(Red Head / Red Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/10

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSC-0051 Conventional Sounder with Red LED Strobe Common Operation(Clear Lens / White Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/11

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSC-0054 Conventional Sounder with LED Strobe Common Operation(Amber Head / Red Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/12

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSC-0055 Conventional Sounder with Red LED Strobe (Clear Lens / White Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/13

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PBS-0015 Universal base sounder (Red) 717a/14Notes:1. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSC-0062 Conventional Sounder with LED Strobe Common Operation(Red Head / White Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/16

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

PSC-0063 Conventional Sounder with LED Strobe Common Operation(Amber Head / White Base)(PSO-0001, PSO-0006, PSO-0003 & PSO-0007 bases)

717a/17

Notes: 1. The above sounder is Type A when used the with the shallow base & Type B

when used with the deep base only2. Meets the requirements of EN 54-3:2001 at tones 1,2,3,6,7 & 13

Bases:

PSO-0001 Shallow base (red)PSO-0006 Shallow base (white)PSO-0003 Deep base (red)PSO-0007 Deep base (white)

Page 432: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

422 31 Dec 2012

Thorn Security Limited, trading as Tyco Safety ProductsDunhams Lane, Letchworth SG6 1BE, United KingdomTel: +44 (0)1462 667700 • Fax: +44 (0)1462 667777E-mail: [email protected] • Website: www.tycosafetyproducts-europe.com

Certificate No: 681g-(cl-1) to EN 54-3: 2001 + A1: 2002 + A2: 2006Certificate No: 378e to EN 54-3: 2001 & EN 54-17: 2005

Certificated Products LPCB Ref. No.

802SB Analogue addressable type A sounder base 681g/01Notes:1. Meets the requirements of EN 54-3 at the following tones: Fast Sweep Dutch Slow Whoop 500Hz to 1200Hz Temporal 3 880Hz

601SB Conventional type A sounder base 681g/02Notes:1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz

601SBD Conventional type A diode sounder base 681g/03Notes:1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz

602SB Conventional type A sounder base 681g/04Notes:1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz

602SBD Conventional type A sounder base 681g/05Notes:1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz

901SB Analogue addressable type A sounder base 681g/06Notes:1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz

912SB Analogue addressable type A sounder base 681g/07Notes:1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz

812SB Analogue addressable type A sounder base 681g/08Notes:1. Meets the requirements of EN 54-3 at the following tones: Temporal 3 880Hz Dutch Slow Whoop 500Hz to 1200Hz Continuous 880Hz

LPSY800-R Symphoni MX addressable loop powered Type A sounder (red) with short circuit isolator 378e/01Notes:1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9.

LPSY800-W Symphoni MX addressable loop powered Type A sounder (white) with short circuit isolator

378e/02

Notes:1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9.

LPSY865 Symphoni MX addressable loop powered Type B sounder (red) with short circuit isolator 378e/03Notes:1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9.

LPAV800-R Symphoni MX addressable loop powered Type A sounder beacon (red) with short circuit 378e/04

Page 433: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

31 Dec 2012 423

Certificated Products LPCB Ref. No.

isolatorNotes:1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9.

LPAV800-W Symphoni MX addressable loop powered Type A sounder beacon (white) with short circuit isolator

378e/05

Notes:1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9.

LPAV865 Symphoni MX addressable loop powered Type B sounder beacon (red) with short circuit isolator

378e/06

Notes:1. Meets the requirements of EN 54-3 at tones 1, 2, 6, 9.

UTC Fire & Security Inc. Trading as Edwards Systems Technology8985 Town Center Parkway, Bradenton, Florida FL34202, USATel: 941 739-42228Website: www.fs.utc.com

Certificate No: 262w to EN 54-3: 2001 + A1: 2002 + A2: 2006Certificate No: 902a-(cl-1) to EN-54-3: 2001 + A1: 2002 + A2: 2006

Certificated Products LPCB Ref. No.

G1x-HD-E Genesis Temporal Horn 262w/02Notes:1. Approved with back boxes G1B-MP and 27193-162. Meets the requirements of EN 54-3 at all volumes and the following tones:- Continuous 3200HZ (interrupted at 40Hz) Temporal 3200Hz (interrupted at 40Hz); 2 pulses 0.5s on / 0.5s off, 1 pulse 0.5s on / 1.5s off, repeat.3. x denotes housing colours Blank = White housing R = Red housing F = White housing with Fire Marking RF = Red housing with Fire Marking.

G1x-HDVM-E Genesis Temporal Horn / Strobe 262w/03Notes:1. Approved with back boxes G1B-MP and 27193-162. Meets the requirements of EN 54-3 at all volumes and the following tones:- Continuous 3200HZ (interrupted at 40Hz) Temporal 3200Hz (interrupted at 40Hz); 2 pulses 0.5s on / 0.5s off, 1 pulse 0.5s on / 1.5s off, repeat.3. x denotes housing colours Blank = White housing R = Red housing F = White housing with Fire Marking RF = Red housing with Fire Marking.

SIGA-AB4G Analogue addressable Type A sounder base 902a/01Notes:1. Certified for used with fire detector models SIGA-IPHSI, SIGA-PHSI, SIGA-PSI, SIGA-IS and SIGA-HRSI.2. Meets the requirements of EN 54-3 with Steady and Temporal tones, and operating voltages from 16-33 VDC. 3. Certified for use with AB4G-SB surface mounting box.

Ancillaries

G1B-MP Back box G1 series, white27193-16 Back box, surface whiteAB4G-SB Surface mounting box

Page 434: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 7ALARM WARNING DEVICES

424 31 Dec 2012

Vimpex LimitedStar Lane, Great Wakering, Essex SS3 0PJ, United KingdomTel: +44 (0) 1702 216999 • Fax: +44 (0) 1702 216699E-mail: [email protected] • Website: www.vimpex.co.uk

Certificate No: 692a to EN 54-3: 2001

Certificated Products LPCB Ref. No.

MBF-6EV-24 6" (150mm) 24Vdc fire alarm bell with aluminium gong 692a/01MBF-8EV 8" (200mm) 24Vdc fire alarm bell with aluminium gong 692a/02MBA-6 + BBX.4 6" (150mm) fire alarm bell with aluminium gong complete with back box 692a/04MBA-8 + BBX.4 8" (200mm) fire alarm bell with aluminium gong complete with back box 692a/05

Zeta Alarm Systems by GLT Exports LimitedDetection House, 72-78 Morfa Road, Swansea SA1 2EN, United KingdomTel: +44 (0)1792 455175 • Fax: +44 (0)1792 455176E-mail: [email protected] • Website: www.gltexports.com

Certificate No: 692a-(cl-1) to EN 54-3: 2001 + A1: 2002

Certificated Products LPCB Ref. No.

ZTB8B - 41-005 8" (200mm) 24Vdc fire alarm bell with aluminimum gong 692a/02ZTB6B/WP - 41-003A 6" (150mm) fire alarm bell with aluminium gong complete with back box. 692a/04ZTB8B/WP - 41-006 8" (200mm) fire alarm bell with aluminium gong complete with back box. 692a/05

Page 435: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 425

This section lists fire resistant cables for use in fire safety, fire detection and fire alarm systems and other applications where specifications require cables with specific performance in the event of a fire.

BS 5839-1:2002+A2:2008 Fire detection and fire alarm systems for buildings. Code of practice for system design, installation, commissioning and maintenance

BS 5839-1:2002+A2:2008 includes requirements for fire resistant cables for fire detection and alarm systems. It calls for ‘Standard’ and ‘Enhanced’ fire resistant cables and defines the requirements for these in Clause 26.2. These cables have to comply with BS EN 60702-1 (with a polymeric sheath), BS 7629 or BS 7846.

‘Standard’ fire resisting cables also have to:a) achieve Class PH30 when tested in accordance with EN 50200:2006.

andb) maintain circuit integrity when exposed to a special flame / mechanical shock / water spray sequence

equivalent to achieving a duration of 30 minutes when tested in accordance with BS EN 50200:2006 Annex E.

‘Enhanced’ fire resisting cables also have to:a) achieve a 120 minute survival when tested in accordance with EN 50200:2006.

andb) maintain circuit integrity when exposed to a special flame / mechanical shock / water spray sequence

equivalent to achieving a duration of 120 minutes when tested in accordance with BS 8434-2:2003+A2:2009.

Cables complying with these requirements are listed as ‘Standard’ or ‘Enhanced’ under BS 5839-1, Clause 26.2.

BS 8519:2010 Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications - Code of practice

BS 8519:2010 gives guidance and recommendations on the selection and installation of power and control cable systems which are required to maintain their circuit integrity for life safety and fire-fighting applications. It also gives specific recommendations for electrical system design for such applications, and recommended limits for survival times.

Category 1: means of escape (30 min fire survival time).• power cables of 20 mm overall diameter and above meeting the 30 min survival time when tested in

accordance with BS 8491, or• control cables meeting the PH30 classification when tested in accordance with BS EN 50200:2006,

and the 30 min survival time when tested in accordance with Annex E of that standard

Category 2: means of escape (60 min fire survival time).• power cables of 20 mm overall diameter and above meeting the 60 min survival time when tested in

accordance with BS 8491 or• control cables meeting the PH60 classification when tested in accordance with BS EN 50200:2006,

and the 120 min survival time when tested in accordance with BS 8434-2:2003+A2:2009

Category 3: fire-fighting (120 min fire survival time). • power cables of 20 mm overall diameter and above meeting the 120 min survival time when tested in

accordance with BS 8491, or• control cables meeting the PH120 classification when tested in accordance with BS EN 50200:2006,

and the 120 min survival time when tested in accordance with Annex B

Page 436: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

426 31 Dec 2012

Building Regulations 2010 - Fire Safety - Approved Document BThe Building Regulations 2010 - Fire Safety - Approved Document B - Volume 2 - Buildings other than dwellinghouses defines a protected power circuit to be able to continue to function during a fire. A protected circuit for operation of equipment in the event of fire should consist of a cable meeting at least the requirements of PH30 when tested in accordance with EN 50200. Larger or complex buildings may require fire protection systems to operate for extended periods during fire and guidance on such systems is given in BS 5839-1, BS 5266-1 and BS 8519.

Other Standards UsedThe other standards and test methods currently used for certification are listed below. This list includes some "withdrawn" standards. Where possible, these will be replaced by the superseding standards when certificates are renewed. However, where withdrawn standards are called up by current standards, certification to the withdrawn standard may need to be maintained until the calling standard is amended to remove the reference:

- BS 6387:1994 Performance requirements for cables required to maintain circuit integrity under fire conditions

- BS 7622-2:1993 Measurement of smoke density of electric cables burning under defined conditions- BS 7629-1:1997 Thermosetting insulated cables with limited circuit integrity when affected by fire. Part 1:

Multicore cables- BS 7629-1:1997 (Incorporating Amendment Nos.1 and 2) Thermosetting insulated cables with limited

circuit integrity when affected by fire. Part 1: Multicore cables (The provisions introduced by amendment No.1: 2004 are effective from 1st April 2004)

- BS 7629-1:2008 Electric cables - Specification for 300/500 V fire resistant screened cables having low emission of smoke and corrosive gases when affected by fire - Part 1: Multicore and multipair cables

- BS 7846:2000 Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire

- BS 7846:2000 (Incorporating Amendment No.1) Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire. (The provisions introduced by amendment No.1: 2004 are affective from 1st April 2004)

- BS 7846:2000 (Incorporating Amendment Nos.1 and 2) Electric cables 600/1000V armoured fire-resistant cables having thermosetting insulation and low emission of smoke and corrosive gases when affected by fire

- BS 7846:2009 Electric cables - Thermosetting insulated, armoured, fire - resistant cables of rated voltage 600/1 000 V, having low emission of smoke and corrosive gases when affected by fire - Specification

- BS 8434-1:2003 Method of test for assessment of the fire integrity of electric cables - Part 1: test for unprotected small cables for use in emergency circuits - BS EN 50200 with addition of water spray

- BS 8434-2:2003+A2:2009 Method of test for assessment of the fire integrity of electric cables - Part 2: test for unprotected small cables for use in emergency circuits- BS EN 50200 with a 930°C flame and with water spray

- BS 8491:2008 Method for assessment of fire integrity of large diameter power cables for use as components for smoke and heat control systems and other certain active fire safety systems

- BS 8519:2010 Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications - Code of practice

- EN 50200:2000 Method of test for resistance to fire of unprotected small cables for use in emergency circuits

- EN 50200:2006 Method of test for resistance to fire of unprotected small cables for use in emergency circuits

- EN 50266:2001 Common test methods for cables under fire conditions - Test for vertical flame spread of vertically mounted bunched wires or cables

- EN 50267-2-1:1999 Common test method for cables under fire conditions- tests on gases evolved during combustion of materials from cables - procedures - Determination of the amount of halogen acid gas

- EN 50267-2-3:1999 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Procedure 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity

- EN 50268-2:2000 Common test methods for cables under fire conditions. Measurement of smoke density of cables burning under defined conditions

- EN 60332-3:2009 Tests on electric and optical fibre cables under fire conditions - Part 3: Test for vertical flame spread of vertically mounted bunched wires or cables

- EN 60702-1:2002 Mineral insulated cables and their terminations with rated voltage not exceeding 750V

Page 437: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 427

- EN 61034-2: 2005 Measurement of smoke density of cables burning under defined conditions- IEC 331:1970 Fire resisting characteristics of electric cables- IEC 60331-1:2009 - Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method

for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0kV and with an overall diameter exceeding 20mm.

- IEC 60331-2:2009 - Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830°C for cables of rated voltage up to and including 0,6/1,0kV and with an overall diameter not exceeding 20mm.

- IEC 60331-21:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 21 Procedure and requirements - Cables of rated voltage up to and including 0,6/1,0kV

- IEC 60331-23:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 23 Procedure and requirements - Electric data cables

- IEC 60331-25:1999 Tests for electric cables under fire conditions - Circuit integrity - Part 25 Procedure and requirements - Optical fibre cables

- IEC 60332-3:2009 Tests on electric cables under fire conditions - Part 3: Tests on bunched wires or cables

- IEC 60754-1:2011 Tests on gases evolved during combustion of materials from cables - Part 1: Determination of the amount of halogen acid gas

- IEC 60754-2:2011 Tests on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity

- IEC 61034-2:2005 Measurement of smoke density of cables burning under defined conditions

Notes:1) The rated voltages Uo/U recognised for BS 6387:1994 are, 300/500V and 450/750V, and for BS 7629 are

300/500V, where Uo is the power-frequency voltage to earth and U is the power-frequency voltage between conductors.

2) Testing of single core cable to BS 6387:1994 is not recognised by the standard. This is because it requires the cable to have at least two metallic elements. Therefore LPCB approval of single core cable is based on the cable being tested in a stainless steel conduit.

3) All BS 6387 approvals must include BS EN 50267-2-1 (acid gas) and BS EN 61034-2 (smoke density) testing

4) MICC Cables approved to BS 5839-1:2002+A2:2008 Clause 26.2 must be sheathed with an overall polymeric covering.

5) BS EN 50200:2006 Annex E and BS 8434-2:2003+A2:2009 provide methods of test that meet the requirements for a special flame / mechanical shock / water spray sequences described in BS 5839-1:2002+A2:2008, Clause 26.2 d) and e), respectively.

6) BS 8491 does not cover cables with a voltage rating that exceeds 600/1000V or where the external cable diameter is less than 20mm.

7) BS 8519 standard covers both Power and Control cables; different test methods apply to each cable type. Control cables up to & including 4.0mm2 can be approved to BS 8519.

2M KABLO SAN. ve TIC. A.S.Canta Fatih Mahallesi Sokak No: 8, 34570 Silivri, Istanbul, TurkeyTel: +90 212 672 7314 • Fax: +90 212 672 7312E-mail: [email protected] • Website: www.2mkab.com

Certificate No: 711a to BS 6387: 1994 and BS EN 50200: 2006 Class PH120

FireKab BMK-SH FE 180Nominal csa of

conductors (mm2)Core Construction

(excluding drain wire & earth)BS 6387 BS EN 50200 LPCB Ref. No.

1.0 (1) 2, 3 & 4 C, W, Z Class PH120 711a/011.5 (1) 2, 3, 4, 5 & 7 C, W, Z Class PH1202.5 (1) 2, 3 & 4 C, W, Z Class PH120

Uo/U 300/500 V

Note:1) Solid conductor only.

Page 438: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

428 31 Dec 2012

Certificate No: 711b to BS EN 50200: 2006 Class PH120

FireKab JE-H(ST)H...BD FE 180 E30-E90Nominal csa of

conductors (mm²)Core Construction

(excluding earth wire)BS EN 50200 LPCB Ref. No.

0.50(1, 2) 1, 2, 4, 8, & 12 pairs Class PH120 711b/011.50(1) 1 & 2 pairs Class PH120

Uo/U 175/300V

Notes:1) Solid conductor only.2) External diameter of this conductor is 0.80mm.

Certificate No: 711c to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

FireKab NGF FE 180 PH30Nominal csa of

conductors (mm²)Core Construction

(excluding drain wire & earth)BS 6387 BS EN 50200 LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z Class PH30 711c/011.5(1) 2, 3 & 4 C, W, Z Class PH302.5(1) 2, 3 & 4 C, W, Z Class PH30

Uo/U 300/500V

Notes:1) Solid conductor only.

AC Electrical Wholesalers LtdCobham Road, Ferndowne Industrial Estate, Wimborne, Dorset BH21 7SJ, United KingdomTel: +44 (0)1202 851800 • Fax: +44 (0)1202 851818Website: www.ac-electrical.com

Certificate No: 682a to BS 7629-1:2008, BS EN 50200:2006 Class PH120, BS EN 50200: 2006 Annex E and BS 5839-1:2002+A2:2008 Clause 26.2d

NoBurn PlatinumNominal csa of

conductor (mm2)

Core Construction

(excluding drainwire & earth)

BS 7629-1(Incorporating Amendments

No.1 & 2)

BS EN 50200

BS 8434-1

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5) 682a/01

1.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the NoBurn Platinum cables listed met the requirements of smoke density of

BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase.

Page 439: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 429

5) The NoBurn Platinum cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2: 2008.

AEI Cables LimitedBirtley, Chester-le-Street, Co. Durham DH3 2RA, United KingdomTel: +44 (0)191 410 3111 • Fax: +44 (0)191 410 8312E-mail: [email protected] • Website: www.aeicables.co.uk

Certificate No: 221b to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

Firetec Unarmoured LSZHNominal csa

of conductor (mm 2)Core Construction

(excluding drain wire & earth)BS 6387

(See note 1)BS EN 50267-2-1(outer covering)

BS EN 61034-2 LPCB Ref. No.

1.0 2, 3 & 4 C, W, Z <0.5% HCl >60% 221b/021.5 2, 3 & 4 C, W, Z <0.5% HCl >60%2.5 2, 3 & 4 C, W, Z <0.5% HCl >60%4.0 2, 3 & 4 C, W, Z <0.5% HCl >60%6.0 2, 3 & 4 C, W, Z <0.5% HCl >60%10 2, 3 & 4 C, W, Z <0.5% HCl >60%16 2, 3 & 4 C, W, Z <0.5% HCl >60%

Uo/U 600/1000V

Note:1. These cables also met Category C, W, Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.

Certificate No: 221c to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

Firetec Single Core LSZHNominal csa

of conductor (mm2)Core

Construction(See note 1)

BS 6387(see notes 2-4)

BS EN 50267-1-1(outer covering)

IEC 60331-21(see notes 8 & 9)

LPCB Ref. No.

1.0 One C, W, Z(5) <0.5% HCl Complies 221c/011.5 One C, W, Z(5) <0.5% HCl Complies2.5 One C, W, Z(5) <0.5% HCl Complies4.0 One C, W, Z(5) <0.5% HCl Complies6.0 One C, W, Z(5) <0.5% HCl Complies10 One C, W, Z(5) <0.5% HCl Complies16 One C, W, Z(6,7) <0.5% HCl Complies25 One C, W, Z(6,7) <0.5% HCl Complies35 One C, W, Z(6,7) <0.5% HCl Complies50 One C(7) <0.5% HCl Complies70 One C(7) <0.5% HCl Complies95 One C(7) <0.5% HCl Complies120 One C(7) <0.5% HCl Complies150 One C(7) <0.5% HCl Complies185 One C(7) <0.5% HCl Complies240 One C(7) <0.5% HCl Complies300 One C(7) <0.5% HCl Complies400 One Complies(10) <0.5% HCl Complies630 One Complies(10) <0.5% HCl Complies800 One Complies(10) <0.5% HCl Complies

1000 One Complies(10) <0.5% HCl Complies

Uo/U 600/1000V

Notes:1. Stranded conductor only.2. Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3. These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4. Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5. To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.

Page 440: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

430 31 Dec 2012

6. To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other metallic element.

7. To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element.

8. These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950ºC and at a voltage rating of 600V.9. The Firetec Single Core LSZH cable also met IEC 60331-21: 1999 when installed in steel conduit.10. Only Clause 10 of BS 6387 was conducted.

Certificate No: 221e to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN 50200: 2006 Annex E & BS 5839-1: 2002+A2:2008 Clause 26.2d

Firetec Standard Multicore LSZHNominal csa

of conductor

(mm2

Core Construction (excluding drain wire and

earth)

BS 7629-1 BS EN 50200

BS EN 50200 Annex E

BS 5839-1Clause

26.2

LPCB Ref. No.

1.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5) 221e/01

2.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

Uo/U 300/500V

Notes: 1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Firetec Standard Multicore LSZH cables listed met the requirements of smoke

density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The Firetec Standard Multicore LSZH cables listed conform to BS 7629-1: 2008, met class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 221f to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min

Firetec Enhanced Multicore LSZHNominal csaof conductor

(mm2)

Core Construction(excluding drain wire &

earth)

BS 7629-1 BS EN 50200

BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH120 120min(4) Enhanced(5) 221f/011.5(1) 2, 3 & 4 Complies(3) Class PH120 120min(4) Enhanced(5)

2.5(1) 2, 3 & 4 Complies(3) Class PH120 120min(4) Enhanced(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH120 120min(4) Enhanced(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Firetec Enhanced Multicore LSZH cables listed met the requirements of smoke

density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2: 2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

5) The Firetec Enhanced Multicore LSZH cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 221h to BS 6387: 1994 and BS EN 60702-1: 2002

Page 441: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 431

Mineral Insulated Cable (light duty)Nominal csa of

conductor (mm2)Core

ConstructionBS 6387 BS EN 60702-1 LPCB Ref. No.

1.0 2, 3, 4 & 7 C, W, Z Complies 221h/011.5 2, 3, 4 & 7 C, W, Z Complies2.5 2, 3, 4 & 7 C, W, Z Complies4.0 2 C, W, Z Complies

Uo/U 300/500 V

Note:1) The above range is certified in both Bare and Served constructions.

Certificate No: 221h to BS 6387: 1994 and BS EN 60702-1: 2002

Mineral Insulated Cable (single core)Nominal csa of

conductor (mm2)Core

ConstructionBS 6387 BS EN 60702-1 LPCB Ref. No.

1.5 One C, W, Z Complies 221h/022.5 One C, W, Z Complies4.0 One C, W, Z Complies6.0 One C, W, Z Complies10 One C, W, Z Complies16 One C, W, Z Complies25 One C, W, Z Complies35 One C, W, Z Complies50 One C, W, Z Complies70 One C, W, Z Complies95 One C, W, Z Complies

120 One C, W, Z Complies150 One C, W, Z Complies185 One C, W, Z Complies240 One C, W, Z Complies300 One C, W, Z Complies400 One C, W, Z Complies

Uo 750V

Notes:1) The above range is certified in both Bare and Served constructions.2) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the

manufacturer.

Certificate No: 221h to BS 6387: 1994 and BS EN 60702-1: 2002

Mineral Insulated Cable (heavy duty)Nominal csa of

conductor (mm2)Core

ConstructionBS 6387 BS EN 60702-1 LPCB Ref. No.

1.5 2, 3, 4, 7, 12 & 19 C, W, Z Complies 221h/032.5 2, 3, 4, 7 & 12 C, W, Z Complies4.0 2, 3 & 4 C, W, Z Complies6.0 2, 3 & 4 C, W, Z Complies10 2, 3 & 4 C, W, Z Complies16 2, 3 & 4 C, W, Z Complies25 2, 3 & 4 C, W, Z Complies

Uo/U 450/750V

Notes:1) The above range is certified in both Bare and Served constructions.2) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the

manufacturer.

Certificate No: 221k to BS 7846: 2009 Category F2

Page 442: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

432 31 Dec 2012

Firetec PowerNominal csa of

conductor (mm2)Core Construction

(see note 1)BS 7846 LPCB Ref. No.

1.5 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 F2(2) 221k/012.5 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 F2(2)

4.0 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 F2(2)

6.0 2, 3, 4 & 5 F2(2)

10 2, 3, 4 & 5 F2(2)

16 2, 3, 4 & 5 F2(2)

Uo/U 600/1000V

Notes:1. Stranded conductors only.2. In meeting the requirements of BS 7846: 2009 Category F2, the Firetec Power cables listed met the requirements for fire resistance

characteristics Category CWZ specified in Clause 11 of BS 6387: 1994.

Certificate No: 221n to BS EN 60702-1: 2002 and BS 6387: 1994

AEI MI CABLE (LIGHT DUTY)Nominal csa of conductor (mm²) Core Construction BS EN 60702-1 BS 6387 LPCB Ref. No.

1.0(1,2) 2, 3, 4 & 7 Complies C,W,Z 221n/011.5(1,2) 2, 3, 4 & 7 Complies C,W,Z2.5(1,2) 2, 3, 4 & 7 Complies C,W,Z4.0(1,2) 2 Complies C,W,Z

Uo/U 300/500V

Notes:1) Solid conductor only2) The above cables are certified in Bare construction only.

Certificate No: 221p to BS 60702-1: 2002, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2: 2009 120min, BS EN 50267-2-1: 1999

AEI MI CABLE (LIGHT DUTY)Nominal csa of

conductor (mm²)

Core construction

BS EN 60702-1 (see

note 3)

BS 6387

BS EN 50200

BS 8434-2

BS 5839-1 Clause 26.2

BS EN 50267-2-1 (outer covering)

LPCB Ref. No.

1.0(1,2) 2, 3, 4 & 7 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl 221p/01

1.5(1,2) 2, 3, 4 & 7 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl

2.5(1,2) 2, 3, 4 & 7 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl

4.0(1,2) 2 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl

Uo/U 300/500V

Notes:1) Solid conductor only.2) The above cables are certified in Served construction only.3) In meeting the requirements of BS EN 60702-1: 2002, the AEI MI CABLE (LIGHT DUTY) listed met the requirements of smoke

density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997.

4) The AEI MI CABLE (LIGHT DUTY) listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200:2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Page 443: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 433

Alpha Fire Services W.L.L.P O Box 11741, Manama, Kingdom of BahrainTel: +973 1773 8100 / +973 3960 7378 • Fax: +973 1773 6161E-mail: [email protected]; [email protected]; [email protected] • Website: www.alphafireservices.com

Certificate No: 568a-(cl-1) to BS 6387: 1994 and BS EN 50267-2-1: 1999

ALPHAFIRE FPC4Nominal csa of

conductors (mm2)Core

ConstructionBS 6387 BS EN 50267-2-1

(outer covering)LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z <0.5%HCl 568a/011.5(1) 2, 3 & 4 C, W, Z <0.5%HCl2.5(1) 2, 3 & 4 C, W, Z <0.5%HCl4.0(2) 2, 3 & 4 C, W, Z <0.5%HCl

Uo/U 300/500 V

Notes:1) Solid and stranded conductors.2) Stranded conductor only.

ATOM KABLO SANAYI VE TICARET A.S.Ankara Karayolu 6. Km, Akkale Bedesi, Denizli 20155, TurkeyTel: +90 258 274 63 52 • Fax: +90 258 274 64 31E-mail: [email protected] • Website: www.atom.com.tr

Certificate No: 905a to BS 7846: 2009 Category F2

ATOM Fire Barrier LNominal csa of

conductor (mm 2)Core construction

(See note 1)BS 7846 LPCB Ref. No.

1.5 2, 3, 4, 5, 7, 12 & 19 F2(2) 905a/012.5 2, 3, 4, 5, 7, 12 & 19 F2(2)

4.0 2, 3, 4, 5, 7, 12 & 19 F2(2)

6.0 2, 3, 4 & 5 F2(2)

10 2, 3, 4 & 5 F2(2)

16 2, 3, 4 & 5 F2(2)

25 2, 3, 4 & 5 F2(2)

35 2, 3, 4 & 5 F2(2)

Uo/U 600/1000V

Notes:1) Stranded conductors only.2) In meeting the requirements of BS 7846: 2009 Category F2, the ATOM Fire Barrier L cables listed met the requirements of smoke

density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, tapes, filler, bedding and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

Certificate No: 905b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and IEC 60331-21: 1999

ATOM Fire Barrier SNominal csa of

conductor (mm²)

Core construction(See note 1)

BS 6387(See notes 2 -

4)

BS EN 50267-2-1

BS61034-2 IEC 60331-21

(See Note 8)

LPCB Ref. No.

1.5 One C, W, Z(5) <0.5% HCl >60% Complies 905b/012.5 One C, W, Z(5) <0.5% HCl >60% Complies4.0 One C, W, Z(5) <0.5% HCl >60% Complies6.0 One C, W, Z(5) <0.5% HCl >60% Complies

Page 444: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

434 31 Dec 2012

Nominal csa ofconductor

(mm²)

Core construction(See note 1)

BS 6387(See notes 2 -

4)

BS EN 50267-2-1

BS61034-2 IEC 60331-21

(See Note 8)

LPCB Ref. No.

10 One C, W, Z(5) <0.5% HCl >60% Complies16 One C, W, Z(6,7) <0.5% HCl >60% Complies25 One C, W, Z(6,7) <0.5% HCl >60% Complies35 One C, W, Z(6,7) <0.5% HCl >60% Complies50 One C, W, Z(6,7) <0.5% HCl >60% Complies70 One C, W, Z(6,7) <0.5% HCl >60% Complies95 One C(7) <0.5% HCl >60% Complies

120 One C(7) <0.5% HCl >60% Complies150 One C(7) <0.5% HCl >60% Complies185 One - <0.5% HCl >60% Complies 240 One - <0.5% HCl >60% Complies300 One - <0.5% HCl >60% Complies400 One - <0.5% HCl >60% Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950oC and at a voltage rating of 600V.

Bahra Cables CompanyCPC Industrial Park, Bahra, Jeddah 21432, Kingdom of Saudi ArabiaTel: +966 25911115, (Toll Free) 8001248111 • Fax: +966 25915683E-mail: [email protected] • Website: www.bahra-cables.com

Certificate No: 1069a to BS 6387: 1994, IEC 60331-21: 1999, BS EN 50267-2-1: 1999, BS EN 50267-2-3: 1999 & BS EN 61034-2: 2005

FSB WiresNominal csa of

conductor (mm²)Core construction

(See note 1)BS 6387

(See notes 2-3)

BS EN 50267-2-1

BS EN 50267-2-3

BS EN 61034-2

IEC 60331-21 note 7)

LPCB Ref. No.

2.5 One C, W, Z(4) <0.5% HCl Complies >60% Complies 1069a/014.0 One C, W, Z(4) <0.5% HCl Complies >60% Complies6.0 One C, W, Z(4) <0.5% HCl Complies >60% Complies10 One C, W, Z(4) <0.5% HCl Complies >60% Complies16 One C, W, Z(5,6) <0.5% HCl Complies >60% Complies25 One C, W, Z(5,6) <0.5% HCl Complies >60% Complies

Uo/U 450/750V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.4) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.5) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.6) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.7) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950ºC and at a voltage rating of 450V.

Page 445: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 435

Bangkok Cable Co Limited93 Moo. 11 Suksawad Road, Naiklongbangplakod, Prasamutchedee, Samutprakarn, 10290, ThailandTel: +662 2544550 • Fax: +662 2543859

Certificate No: 576a to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 50268-2: 2000

450/750V Low smoke halogen free fire resistant cableNominal csa of

conductor (mm2)Core

Construction(see note 1)

BS 6387(see note 2-4)

BS EN 50267-2-1(outer covering)

BS EN 61034-2 LPCB Ref. No.

1.5 One C, W, Z <0.5% HCl >60% 576a/012.5 One C, W, Z <0.5% HCl >60%4.0 One C, W, Z <0.5% HCl >60%6.0 One C, W, Z <0.5% HCl >60%10 One C, W, Z <0.5% HCl >60%16 One C, W, Z <0.5% HCl >60%25 One C, W, Z <0.5% HCl >60%35 One C, W, Z <0.5% HCl >60%50 One C, W, Z <0.5% HCl >60%70 One C, W, Z <0.5% HCl >60%95 One C, W, Z <0.5% HCl >60%

120 One C, W, Z <0.5% HCl >60%150 One - <0.5% HCl >60%185 One - <0.5% HCl >60%240 One - <0.5% HCl >60%300 One - <0.5% HCl >60%400 One - <0.5% HCl >60%500 One - <0.5% HCl >60%630 One - <0.5% HCl >60%

Uo/U 450/750V

Notes:1) Stranded conductor only2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.4) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.

Certificate No: 576a to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 50268-2: 2000

600/1000V XLPE/Armoured/Low smoke halogen free fire resistant cableNominal csa of

conductor (mm2)Core

Construction(see note 1)

BS 6387(see note 2)

BS EN 50267-2-1(outer covering)

BS EN 61034-1 LPCB Ref. No.

1.5 One, 2, 3 & 4 C, W, Z <0.5% HCl >60% 576a/022.5 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%4.0 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%6.0 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%10 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%16 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%25 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%35 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%50 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%70 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%95 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%120 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%150 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%185 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%240 One, 2, 3 & 4 C, W, Z <0.5% HCl >60%300 One & 2 C, W, Z <0.5% HCl >60%400 One C, W, Z <0.5% HCl >60%

Uo/U 600/1000V

Page 446: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

436 31 Dec 2012

Notes:1) Stranded conductors only2) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387

Cavicel SpAVia Caduti del Lavoro, 18/A, 20096 Pioltello, Milan, ItalyTel: +39 02 9216 0521 • Fax: +39 02 9216 0753E-mail: [email protected] • Website: www.cavicel.com

Certificate No: 217d to BS 6387:1994, BS EN 50267-2-1:1999

FIRECEL SR 112Nominal csa of conductor (mm2) Core Construction

(see note 1)BS 6387

(see notes 2, 3, 4 & 5)BS EN 50267-2-1(outer covering)

LPCB Ref. No.

1.5 One C, W, Z <0.5% HCI 217d/012.5 One C, W, Z <0.5% HCI4.0 One C, W, Z <0.5% HCI6.0 One C, W, Z <0.5% HCI10 One C, W, Z <0.5% HCI16 One C, W, Z <0.5% HCI25 One C, W, Z <0.5% HCI

Uo/U 450/750 V

Notes:1) Stranded conductor only.2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) To satisfy the requirement of BS 6387, testing for C, W and Z categories was conducted using a 20mm steel conduit as the other

metallic element.4) For large size cables, the category C testing was conducted using a 38mm steel conduit as the other metallic element.5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.

Certificate No: 217f to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006, BS EN 50200: 2006 Annex E, BS 5839-1: 2002+A2: 2008

FIRECEL SR 114H Fire Resistant CableNominal csa of

conductor (mm 2)Core

Construction(excluding

drainwire and

earth)

BS 7629-1 BS6387 BS EN 50200

BS EN 50200 Annex E

BS 5839-1 Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(4) C, W, Z Class PH30 30min(5) Standard(6) 217f/011.5(2) 2, 3 & 4 Complies(4) C, W, Z Class PH30

& PH6030min(5) Standard(6)

2.5(2) 2, 3 & 4 Complies(4) C, W, Z Class PH30 & PH60

30min(5) Standard(6)

4.0(3) 2, 3 & 4 Complies(4) C, W, Z Class PH30 & PH60

30min(5) Standard(6)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Solid & Stranded conductors.3) Stranded conductor only.4) In meeting the requirements of BS 7629-1: 2008, the FIRECEL SR 114H cables listed met the requirements of smoke density of BS

EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

5) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

6) The FIRECEL SR 114H cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Page 447: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 437

Certificate No: 217g to BS 7629-1:2008, BS 6387:1994, BS EN 50200:2006, BS 8434-2:2003+A3:2009, BS 5839-1:2002+A2:2008

FIRECEL SR 114E Fire Resistant CableNominal csa of

conductor (mm2)Core

Construction(excluding drain

wire & earth)

BS 7629-1 BS 6387 BS EN 50200 BS 8434-2 BS 5839-1 Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(4) C, W ,Z Class PH120 120min(5) Enhanced(6) 217g/011.5(2) 2, 3 & 4 Complies(4) C, W, Z Class PH120 120min(5) Enhanced(6)

2.5(2) 2, 3 & 4 Complies(4) C, W, Z Class PH120 120min(5) Enhanced(6)

4.0(3) 2, 3 & 4 Complies(4) C, W, Z Class PH120 120min(5) Enhanced(6)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Solid & Stranded conductors.3) Stranded conductor only.4) In meeting the requirements of BS 7629-1: 2008, the FIRECEL SR 114E cables listed met the requirements of smoke density of BS

EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

5) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

6) The FIRECEL SR 114E cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 217h to BS 6387: 1994 and BS EN 60702-1: 2002

FIRECEL MI 900 LNominal csa of

conductor (mm 2)Core Construction

(see note 1)BS 6387 BS EN 60702-1 LPCB Ref. No.

1.0 2, 3, 4 & 7 C,W,Z Complies 217h/011.5 2, 3, 4 & 7 C,W,Z Complies2.5 2, 3, 4 & 7 C,W,Z Complies4.0 2 C,W,Z Complies

Uo/U 300/500 V

Notes:1) The above range is certified in both Bare and Served constructions.

Certificate No: 217h to BS 6387: 1994 and BS EN 60702-1: 2002

FIRECEL MI 901 HNominal csa of

conductor (mm 2)Core construction

(see note 1)BS 6387

(see note 2)BS EN 60702-1 LPCB Ref. No.

1.5 One C,W,Z Complies 217h/022.5 One C,W,Z Complies4.0 One C,W,Z Complies6.0 One C,W,Z Complies10 One C,W,Z Complies16 One C,W,Z Complies25 One C,W,Z Complies35 One C,W,Z Complies50 One C,W,Z Complies70 One C,W,Z Complies95 One C,W,Z Complies120 One C,W,Z Complies150 One C,W,Z Complies185 One C,W,Z Complies240 One C,W,Z Complies300 One C,W,Z Complies400 One C,W,Z Complies

Page 448: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

438 31 Dec 2012

Uo 750V

Notes:1) The above range is certified in both Bare and Served constructions.2) For cable with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the

manufacturer.

Certificate No: 217h to BS 6387: 1994 and BS EN 60702-1: 2002

FIRECEL MI 900 HNominal csa of

conductor (mm 2)Core Construction

(see note 1)BS 6387

(see note 2)BS EN 60702-1 LPCB Ref. No.

1.5 2, 3, 4, 7, 12 & 19 C,W,Z Complies 217h/032.5 2, 3, 4, 7 &12 C,W,Z Complies4.0 2, 3 & 4 C,W,Z Complies6.0 2, 3 & 4 C,W,Z Complies10 2, 3 & 4 C,W,Z Complies16 2, 3 & 4 C,W,Z Complies25 2, 3 & 4 C,W,Z Complies

Uo/U 450/750V

Notes:1) The above range is certified in both Bare and Served constructions.2) For cable with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the

manufacturer.

Context Plus Ltd175 Mauldeth Road, Fallowfield, Manchester M14 6SG, United KingdomTel: +44 (0)161 257 2541 • Fax: +44 (0)161 225 8817E-mail: [email protected] • Website: www.xportsales.com

Certificate No: 682a-(cl-3) to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2: 2008 Clause 26.2d

Context PlusNominal csaof conductor

(mm 2)

CoreConstruction

(excluding drainwire & earth)

BS 7629-1 BS EN 50200 BS EN 50200Annex E

BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5) 682a/011.5(1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Context Plus cables listed met the requirements of smoke density of BS EN

61034-2: 2005 fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The Context Plus cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1 :2002+A2:2008.

Page 449: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 439

Dätwyler CablesUnit of Dätwyler Switzerland Inc, Gotthardstrasse 31, CH-6460 Altdorf, SwitzerlandTel: +41 41 875 1122 • Fax: +41 41 875 1860E-mail: [email protected] • Website: www.daetwyler-cables.com

Certificate No: 172b to BS 7629-1: 2008, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E 30min and BS 5839-1: 2002+A2:2008 Clause 26.2d

Pyrofil Standard Fire Safety CableNominal csa of

conductor (mm2)Core Construction

(excludingdrainwire & earth)

BS 7629-1 BS 6387 BS EN 50200 BS EN 50200Annex E

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) C, W, Z Class PH30 30min(4) Standard(5) 172b/011.5(2) 2, 3 & 4 Complies(3) C, W, Z Class PH30 30min(4) Standard(5)

2.5(2) 2, 3 & 4 Complies(3) C, W, Z Class PH30 30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Solid and stranded conductors.3) In meeting the requirements of BS 7629-1: 2008, the Pyrofil Standard Fire Safety Cables listed met the requirements of smoke density

of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the outer covering, binder tape and insulation when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The Pyrofil Standard Fire Safety Cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 172c to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 120min and BS 5839-1: 2002+A2:2008 Clause 26.2e

Pyrofil Enhanced Fire Safety CableNominal csa of

conductor (mm²)

Core construction (excluding drain wire and

earth)

BS 7629-1 BS 6387

BS EN 50200

BS 8434-2

BS 5839-1Clause

26.2

LPCB Ref. No.

1.5(1) 2 Complies(2) C,W,Z Class PH120

120min(3) Enhanced(4) 172c/01

2.5(1) 2 Complies(2) C,W,Z Class PH120

120min(3) Enhanced(4)

Uo/U 300/500V

Notes:1) Solid and stranded conductors.2) In meeting the requirements of BS 7629-1: 2008, the Pyrofil Enhanced Fire Safety Cables listed met the requirements of smoke

density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999.

3) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

4) The Pyrofil Enhanced Fire Safety Cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 200+A2:2008.

Certificate No: 172d to BS 6387: 1994, BS EN 61034-2: 2005, BS EN 50267-2-1: 1999, IEC 60754-1: 1994,BS EN 50267-2-3: 1999 and IEC 60754-2-am1: 1997

Page 450: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

440 31 Dec 2012

Pyrofil Fire Safety BS 6387 CWZNominal csa of

conductor (mm²)Core

Construction (see note 1)

BS 6387

BS EN 50267-2-1 (see note 2)

BS EN 50267-2-3 (see note 3)

BS EN 61034-2

LPCB Ref. No.

1.5 2 C, W, Z

<0.5% HCl Complies >60% 172d/01

2.5 2 C, W, Z

<0.5% HCl Complies >60%

Uo/U 300/500V

Notes:1) Solid conductors only.2) In achieving less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1:

1999, the Pyrofil Fire Safety BS 6387 CWZ cables listed also met the requirements of IEC 60754-1: 1994.3) In achieving a weighted average of pH greater than 4.3 and a weighted average of Conductivity less than 10µS/mm on the constituent

materials when tested in accordance with BS EN 50267-2-3: 1999, the Pyrofil Fire Safety BS 6387 CWZ cables listed also met the requirements of IEC 60754-2-am1: 1997.

Doncaster CablesMillfields Industrial Estate, Arksey Lane, Bentley, Doncaster, South Yorkshire DN5 0SJ, United KingdomTel: +44 (0)1302 821700 • Fax: +44 (0)1302 821701E-mail: [email protected] • Website: www.doncastercables.com

Certificate No: 338a to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E & BS 5839-1: 2002+A2:2008 Clause 26.2d

Firesure CablesNominal csa of

conductor (mm2)Core construction (drain

wire & earth)BS 7629-1 BS EN

50200BS EN 50200

Annex EBS 5839-1

Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH30

30min(4) Standard(5) 338a/01

1.5(1) 2, 3 & 4 Complies(3) Class PH30

30min(4) Standard(5)

2.5(2) 2, 3 & 4 Complies(3) Class PH30

30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH30

30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Firesure Cables listed met the requirements of smoke density of BS EN 61034-

2: 2005, fire resistance requirements of CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binding tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d of BS 5839-1: 2002+A2:2008.

5) The Firesure Cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 338b to BS 7629-1: 2008, BS 6387: 1994, IEC 60331-21: 1999, IEC 60332-3-24: 2000+A1:2008, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 120min and BS 5839-1: 2002+A2:2008 Clause 26.2e

Page 451: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 441

FIRESURE PLUSNominal csa of

conductor (mm 2)

Core construction (excluding

drain wire & earth)

BS 7629-1 BS 6387

IEC 60331-21

IEC 60332-3-

24

BS EN 50200

BS8434-2

BS 5839-1 LPCB Ref. No.

1.0 (1) 2, 3 & 4 Complies(3) C,W,Z Complies(4) Complies Class PH120

120min(5) Enhanced(6) 338b/01

1.5(1) 2, 3 & 4 Complies(3) C,W,Z Complies(4) Complies Class PH120

120min(5) Enhanced(6)

2.5(1) 2, 3 & 4 Complies(3) C,W,Z Complies(4) Complies Class PH120

120min(5) Enhanced(6)

4.0(2) 2, 3 & 4 Complies(3) C,W,Z Complies(4) Complies Class PH120

120min(5) Enhanced(6)

Uo/U 300/500V

Notes:1) Solid conductor only2) Stranded conductor only3) In meeting the requirements of BS 7629-1: 2008, the FIRESURE PLUS listed met the requirements of smoke density of BS EN

61034-2: 2005, fire resistance requirements of CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binding tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999.

4) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950ºC.5) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase

and an additional 60min for the fire, impact and water phase as described in Clause 26.2e of BS 5839-1: 2002+A2:2008.6) The FIRESURE PLUS cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200:

2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for a enhanced fire resistant cable as described in Clause 26.2e of BS 5839-1: 2002+A2:2008.

Certificate No: 338c to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH120, BS EN 50200: 2006 Annex E, BS 5839-1: 2002 + A2: 2008 Clause 26.2d

FIRESURE 500Nominal csa of

conductor (mm²)

Core construction

(excluding drainwire & earth)

BS 7629-1 BS 6387

BS EN 50200

BS EN 50200

Annex E

BS 5839-1 Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(2) C,W,Z Class PH120 30min(3) Standard(4) 338c/01

1.5(1) 2, 3 & 4 Complies(2) C,W,Z Class PH120 30min(3) Standard(4)

2.5(1) 2, 3 & 4 Complies(2) C,W,Z Class PH120 30min(3) Standard(4)

Uo/U 300/500V

Notes:1) Solid conductor only.2) In meeting the requirements of BS 7629-1: 2008, the FIRESURE 500 cables listed met the requirements of smoke density of BS EN

61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

3) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

4) The FIRESURE 500 cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Draka (Malaysia) Sdn. Bhd.Lot 48, Jalan Industri 13, Alor Gajah Industrial Estate, 78000 Alor Gajah, Malacca, MalaysiaTel: +606 556 3833 • Fax: +606 556 3282E-mail: [email protected] • Website: www.draka.com.my

Certificate No: 994a to BS 6387: 1994, IEC 60331-21: 1999, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

Page 452: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

442 31 Dec 2012

FIRETUF Classic MI SIFER (s)Nominal csa of conductor

(mm 2)Core

construction(See note 1)

BS 6387(See notes 2 -

4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21

(See note 9)

LPCB Ref. No.

1.5 One C, W, Z(5) <0.5% HCI >60% Complies 994a/012.5 One C, W, Z(5) <0.5% HCI >60% Complies4.0 One C, W, Z(6, 7) <0.5% HCI >60% Complies6.0 One C, W, Z(6, 7) <0.5% HCI >60% Complies10 One C, W, Z(6, 7) <0.5% HCI >60% Complies16 One C, W, Z(6, 7) <0.5% HCI >60% Complies25 One C, W, Z(6, 7) <0.5% HCI >60% Complies35 One C, W, Z(6, 7) <0.5% HCI >60% Complies50 One C, W, Z(6, 7) <0.5% HCI >60% Complies70 One C( 7) <0.5% HCI >60% Complies95 One C( 7) <0.5% HCI >60% Complies120 One C( 7) <0.5% HCI >60% Complies150 One C( 7) <0.5% HCI >60% Complies185 One C( 7) <0.5% HCI >60% Complies240 One C( 7) <0.5% HCI >60% Complies300 One C( 7) <0.5% HCI >60% Complies400 One Complies(8) <0.5% HCI >60% Complies500 One Complies(8) <0.5% HCI >60% Complies630 One Complies(8) <0.5% HCI >60% Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the calbe having only one core.3) These cables also met category C, W, Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z.categories were conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) Only Clause 10 of BS 6387 was conducted.9) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 750oC and at a voltage rating of 600V.

Draka UK LimitedAlfreton Road, Derby DE21 4AE, United KingdomTel: +44 (0)1332 345431 • Fax: +44 (0)1332 331237 E-mail: [email protected] • Website: www.drakauk.com

Certificate No: 361b to BS 6387: 1994 and BS EN 50267-2-1: 1999

FTPNominal csa of

conductor (mm2)Core

Construction (excluding drain

wire & earth)

BS 6387(see notes 2 & 3)

BS EN 50267-2-1 (outer covering)

LPCB Ref. No.

1.5(1) 2, 3 & 4 C,W,Z <0.5% HCI 361b/012.5(1) 2, 3 & 4 C,W,Z <0.5% HCI4.0(1) 2, 3 & 4 C,W,Z <0.5% HCI6.0(1) 2, 3 & 4 C,W,Z <0.5% HCI10(1) 2, 3 & 4 C,W,Z <0.5% HCI16(1) 2, 3 & 4 C,W,Z <0.5% HCI25(1) 2, 3 & 4 C,W,Z <0.5% HCI35(1) 2, 3 & 4 C,W,Z <0.5% HCI50(1) 2, 3 & 4 C,W,Z <0.5% HCI70(1) 2, 3 & 4 C,W,Z <0.5% HCI95(1) 2, 3 & 4 C,W,Z <0.5% HCI

120(1) 2, 3 & 4 C,W,Z <0.5% HCI150(1) 2, 3 & 4 C,W,Z <0.5% HCI185(1) 2, 3 & 4 C,W,Z <0.5% HCI240(1) 2, 3 & 4 C,W,Z <0.5% HCI

Page 453: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 443

Nominal csa of conductor (mm2)

CoreConstruction

(excluding drain wire & earth)

BS 6387(see notes 2 & 3)

BS EN 50267-2-1 (outer covering)

LPCB Ref. No.

300(1) 2, 3 & 4 C,W,Z <0.5% HCI400(1) 2, 3 & 4 C,W,Z <0.5% HCI

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) The FTP cable also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.3) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the

manufacturer.

Certificate No: 361c to BS 6387: 1994 and BS EN 50267-2-1: 1999

Firetuf® FTPU 950 Fire Resistant Mifer OHLS® cableNominal csa of

conductor (mm2)Core

Construction(excluding drain

wire & earth)

BS 6387(see notes 1 & 2)

BS EN 50267-2-1(outer covering)

LPCB Ref. No.

1.5 2, 3, 4 & 5 C, W, Z <0.5% HCl 361c/011.5 7,10,12,16,20,21 & 30 C, W, Z <0.5% HCl2.5 2, 3, 4 & 5 C, W, Z <0.5% HCl2.5 7,10,12,16,20,21 & 30 C, W, Z <0.5% HCl4.0 2, 3, 4 & 5 C, W, Z <0.5% HCl6.0 2, 3, 4 & 5 C, W, Z <0.5% HCl10 2, 3, 4 & 5 C, W, Z <0.5% HCl16 2, 3, 4 & 5 C, W, Z <0.5% HCl25 2, 3, 4 & 5 C, W, Z <0.5% HCl35 2, 3, 4 & 5 C, W, Z <0.5% HCl50 2, 3, 4 & 5 C, W, Z <0.5% HCl70 2, 3, 4 & 5 C, W, Z <0.5% HCl95 2, 3, 4 & 5 C, W, Z <0.5% HCl

120 2, 3 & 4 C, W, Z <0.5% HCl150 2, 3 & 4 C, W, Z <0.5% HCl185 2, 3 & 4 C, W, Z <0.5% HCl240 2, 3 & 4 C, W, Z <0.5% HCl300 2, 3 & 4 C, W, Z <0.5% HCl400 2, 3 & 4 C, W, Z <0.5% HCl

120/70 4+ Concentric Earth C, W, Z <0.5% HCl150/70 4+ Concentric Earth C, W, Z <0.5% HCl185/95 4+ Concentric Earth C, W, Z <0.5% HCl

240/120 4+ Concentric Earth C, W, Z <0.5% HCl50/25 4+ Concentric Earth C, W, Z <0.5% HCl70/35 4+ Concentric Earth C, W, Z <0.5% HCl95/50 4+ Concentric Earth C, W, Z <0.5% HCl

Uo/U 450/750V

Notes:1) The Firetuf® FTPU 950 Fire Resistant Mifer OHLS® cable also met category C,W,Z when tested for voltage rating 600/1000V which

is not recognised by BS 6387.2) For cable with an outside diameter of in excess of 20mm, the category Z tests were conducted in accordance with guidance

from the manufacturer.

Certificate No: 361d to BS7629-1: 2008, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2d, BS EN 50200: 2006 Class PH30 and BS EN 50200: 2006 Annex E

FT30Nominal csa of conductor

(mm2)

CoreConstruction

(excluding drainwire & earth)

BS 7629-1 BS 6387 BS EN 50200 BS EN 50200Annex E

BS 5839-1Clause 26.2

LPCB Ref. No.

1.5 2, 3 & 4 Complies (1) C, W, Z Class PH30 30min (2) Standard (3) 361d/012.5 2, 3 & 4 Complies (1) C, W, Z Class PH30 30min (2) Standard (3)

4.0 2, 3 & 4 Complies (1) C, W, Z Class PH30 30min (2) Standard (3)

Page 454: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

444 31 Dec 2012

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 2008, the FT30 cables listed met the requirements of smoke density of BS EN 61034-2:

2005 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

2) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

3) The FT30 cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 361e to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2d, BS EN 50200: 2006 Class PH30 and BS EN 50200: 2006 Annex E

FT EMCNominal csa of

conductor (mm2)Core

Construction(excluding drain

wire & earth)

BS 7629-1 BS EN 50200 BS EN 50200Annex E

BS 5839-1Clause 26.2

LPCB Ref. No.

1.5 2 Complies(1) Class PH30 30min(2) Standard(3) 361e/012.5 2 Complies(1) Class PH30 30min(2) Standard(3)

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 2008, the FT EMC cables listed met the requirements of smoke density of BS EN 61034-

2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999 .

2) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

3) The FT EMC cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 361f to BS 7629-1: 2008, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min

FT120Nominal csa of

conductor (mm2)

Core Construction(excluding drain

wire and earth)

BS 7629-1 BS 6387

BS EN 50200

BS 8434-2

BS 5839-1Clause 26.2

LPCB Ref. No.

1.5 2, 3 & 4 Complies(1)

C,W,Z Class PH120 120min (2) Enhanced(3) 361f/01

2.5 2, 3 & 4 Complies(1)

C,W,Z Class PH120 120min (2) Enhanced(3)

4.0 2, 3 & 4 Complies(1)

C,W,Z Class PH120 120min (2) Enhanced(3)

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 2008, the FT120 cables listed met the requirements of smoke density of BS EN 61034-2:

2005 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

2) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

3) The FT120 cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 361g to BS 8491: 2008, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and BS EN 60332-3-24: 2009

Page 455: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 445

FTP120Nominal csa

of conductor

(mm 2)

Core Construction(excluding earth

wire)

BS 8491(fire survival

time)

BS EN 50267-2-1

BS EN 61034-2

BS EN 60332-3-24

LPCB Ref. No.

2.5(1,2) 7 120min <0.5% HCl >60% Complies 361g/014.0(1,2) 2, 3, 4 & 7 120min <0.5% HCl >60% Complies6.0(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies10(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies16(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies25(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies35(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies50(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies70(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies95(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies120(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies150(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies185(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies240(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies300(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies400(1,2) 2, 3 & 4 120min <0.5% HCl >60% Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) All cables have the blue core designated as a Neutral conductor; only phase to earth voltage was applied to the 2 core cables.

Certificate No: 361h to BS6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

FT SIFER 950iNominal csa of

conductor (mm 2)Core Construction

(see note 1)BS 6387

(see notes 2-4)IEC 60331-21 (see note 8)

BS EN 50267-2-1 (outer covering)

LPCB Ref. No.

1.5 One C,W,Z(5) Complies <0.5% HCI 361h/012.5 One C,W,Z(5) Complies <0.5% HCI4.0 One C,W,Z(5) Complies <0.5% HCI6.0 One C,W,Z(5) Complies <0.5% HCI10 One C,W,Z(5) Complies <0.5% HCI16 One C,W,Z(5) Complies <0.5% HCI25 One C,W,Z(6,7) Complies <0.5% HCI35 One C,W,Z(6,7) Complies <0.5% HCI50 One C,W,Z(6,7) Complies <0.5% HCI70 One C,W,Z(6,7) Complies <0.5% HCI95 One - Complies <0.5% HCI120 One - Complies <0.5% HCI150 One - Complies <0.5% HCI185 One - Complies <0.5% HCI240 One - Complies <0.5% HCI300 One - Complies <0.5% HCI400 One - Complies <0.5% HCI500 One - Complies <0.5% HCI630 One - Complies <0.5% HCI

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) FT SIFER 950i cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950ºC and at a voltage rating of

600V.

Page 456: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

446 31 Dec 2012

Certificate No: 361h to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

FT SIFER 950sNominal csa of

conductor (mm 2)Core Construction

(see note 1)BS 6387

(see notes 2-4)IEC 60331-21 (see note 8)

BS EN 50267-2-1 (outer covering)

LPCB Ref. No.

1.5 One C,W,Z(5) Complies <0.5% HCI 361h/022.5 One C,W,Z(5) Complies <0.5% HCI4.0 One C,W,Z(5) Complies <0.5% HCI6.0 One C,W,Z(6,7) Complies <0.5% HCI10 One C,W,Z(6,7) Complies <0.5% HCI16 One C,W,Z(6,7) Complies <0.5% HCI25 One C,W,Z(6,7) Complies <0.5% HCI35 One C(7) Complies <0.5% HCI50 One C(7) Complies <0.5% HCI70 One C(7) Complies <0.5% HCI95 One - Complies <0.5% HCI120 One - Complies <0.5% HCI150 One - Complies <0.5% HCI185 One - Complies <0.5% HCI240 One - Complies <0.5% HCI300 One - Complies <0.5% HCI400 One - Complies <0.5% HCI500 One - Complies <0.5% HCI630 One - Complies <0.5% HCI800 One - Complies <0.5% HCI

1000 One - Complies <0.5% HCI

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) The FT SIFER 950s cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950ºC and at a voltage

rating of 600V.

Dubai Cable Company (Private) LimitedDucab-M2, Plot No. - J6 14-15-16,, Sector - M41, Industrial City of Abu Dhabi-1, Mussafah, Abu Dhabi, United Arab EmiratesTel: +9714 815 8888 • Fax: +9714 815 8433E-mail: [email protected] • Website: www.ducab.com, Sales office: PO Box 11529, Dubai, UAE

Certificate No: 949a to BS 7846: 2009

Ducab Flam BICC 4Nominal csa of

conductor (mm 2)Core construction

(see note 1)BS 7846 LPCB Ref. No.

1.5 2, 3 & 4 F2(2) 949a/012.5 2, 3 & 4 F2(2)

4.0 2, 3 & 4 F2(2)

6.0 2, 3 & 4 F2(2)

10 2, 3 & 4 F2(2)

Uo/U 600/1000V

Notes:

1. Stranded conductors only.

Page 457: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 447

2. In meeting the requirements of BS 7846: 2009 Category F2, the Ducab Flam BICC 4 cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, tapes, filler, bedding and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

Dubai Cable Company (Private) Limited, Trading as DucabOld Abu Dhabi Road, Jebel Ali, Dubai, United Arab EmiratesTel: +9714 815 8888 • Fax: +9714 815 8433E-mail: [email protected] • Website: www.ducab.com, Sales office: PO Box 11529, Dubai, UAE

Certificate No: 781a to BS 7846: 2009

Ducab Flam BICC 4Nominal csa of

conductor (mm 2)Core Construction

(see note 1)BS 7846 LPCB Ref. No.

1.5 2, 3 & 4 F2(2) 781a/012.5 2, 3 & 4 F2(2)

4.0 2, 3 & 4 F2(2)

6.0 2, 3 & 4 F2(2)

10 2, 3 & 4 F2(2)

16 2, 3 & 4 F2(2)

25 2, 3 & 4 F2(2)

35 2, 3 & 4 F2(2)

Uo/U 600/1000V

Notes1) Stranded conductor only.2) In meeting the requirements of BS 7846: 2009 Category F2, the Ducab Flam BICC 4 cables met the requirements for fire resistance

characteristics category CWZ specified in Clause 11 of BS 6387: 1994.

Certificate No: 781b to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU)

Ducab Flam BICC 4Nominal csa of

conductor (mm2)Core Construction

(see Note 1)BS 7846

(see Notes 2 & 3)LPCB Ref. No.

1.5 2, 3 & 4 F2 781b/012.5 2, 3 & 4 F24.0 2, 3 & 4 F26.0 2, 3 & 4 F210 2, 3 & 4 F216 2, 3 & 4 F225 2, 3 & 4 F235 2, 3 & 4 F2

Uo/U 600/1000 V

Notes

1) Stranded conductors only.2) In meeting the requirements of BS 7846: 2000 Category F2, the Ducab Flam BICC 4 cables met the requirements for fire resistance

characteristics category CWZ specified in Clause 11 of BS 6387: 1994.3) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the

CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 781a covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2)

Page 458: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

448 31 Dec 2012

Certificate No: 781c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and IEC 60331-21: 1999

Ducab Flam BICC 1Nominal csa of conductor

(mm 2)Core

Construction(see note 1)

BS 6387(see notes 2

- 5)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21

(see note 6)

LPCB Ref. No.

1.5 One C, W, Z <0.5%HCl >60% Complies 781c/012.5 One C, W, Z <0.5%HCl >60% Complies4.0 One C, W, Z <0.5%HCl >60% Complies6.0 One C, W, Z <0.5%HCl >60% Complies10 One C, W, Z <0.5%HCl >60% Complies

Uo/U 600/1000V

Notes:

1) Stranded conductor only.2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.4) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.6) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950oC and at a voltage rating of 600V.

Dubai Cable Company (Private) Limited, Trading as DucabDucab-M1, Plot No. - 2D12,3D2,4D2,5D2, Sector - M41, Industrial City of Abu Dhabi-1, Mussafah, Abu Dhabi, United Arab EmiratesTel: +9714 815 8888 • Fax: +9714 815 8433E-mail: [email protected] • Website: www.ducab.com

Sales office:PO Box 11529, Dubai, United Arab Emirates

Certificate No: 782a to BS 7846: 2009

Ducab Flam BICC 4Nominal csa of

conductor (mm2)Core Construction

(see note 1)BS 7846 LPCB Ref. No.

16 2, 3 & 4 F2(2) 782a/0125 2, 3 & 4 F2(2)

35 2, 3 & 4 F2(2)

50 2, 3 & 4 F2(2)

70 2, 3 & 4 F2(2)

95 2, 3 & 4 F2(2)

120 2, 3 & 4 F2(2)

150 2, 3 & 4 F2(2)

185 2, 3 & 4 F2(2)

240 2, 3 & 4 F2(2)

300 2, 3 & 4 F2(2)

400 2, 3 & 4 F2(2)

Uo/U 600/1000V

Notes:1) Stranded conductors only.2) In meeting the requirements of BS 7846: 2009 Category F2, the Ducab Flam BICC 4 cables met the requirements for fire resistance

characteristics category CWZ specified in Clause 11 of BS 6387:1994.

Page 459: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 449

Certificate No: 782b to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU)

Ducab Flam BICC 4Nominal csa of

conductor (mm2)Core Construction

(see note 1)BS 7846

(see notes 2 & 3)LPCB Ref. No.

16 2, 3 & 4 F2(2) 782b/0125 2, 3 & 4 F2(2)

35 2, 3 & 4 F2(2)

50 2, 3 & 4 F2(2)

70 2, 3 & 4 F2(2)

95 2, 3 & 4 F2(2)

120 2, 3 & 4 F2(2)

150 2, 3 & 4 F2(2)

185 2, 3 & 4 F2(2)

240 2, 3 & 4 F2(2)

300 2, 3 & 4 F2(2)

400 2, 3 & 4 F2(2)

Uo/U 600/1000 V

Notes:1) Stranded conductors only.2) In meeting the requirements of BS 7846: 2000 Category F2, the Ducab Flam BICC 4 cables listed met the requirements for fire

resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994.3) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the

CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 782a covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2)

Certificate No: 782c to BS 6387: 1994, IEC 60331-21: 1999, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

Ducab Flam BICC 1Nominal csa

ofconductor

mm 2

Core construction (See note 1)

BS 6387(See notes 2 - 4)

BS EN 50267-2-1

BS EN 61034-2 IEC 60331-21 (See note 8)

LPCB Ref. No.

1.5 One C,W,Z(5) <0.5% HCl >60% Complies 782c/012.5 One C,W,Z(5) <0.5% HCl >60% Complies4.0 One C,W,Z(5) <0.5% HCl >60% Complies6.0 One C,W,Z(5) <0.5% HCl >60% Complies10 One C,W,Z(5) <0.5% HCl >60% Complies16 One C,W,Z(6,7) <0.5% HCl >60% Complies25 One C,W,Z(6,7) <0.5% HCl >60% Complies35 One C,W,Z(6,7) <0.5% HCl >60% Complies50 One C,W,Z(6,7) <0.5% HCl >60% Complies70 One C,W,Z(6,7) <0.5% HCl >60% Complies95 One C,W,Z(6,7) <0.5% HCl >60% Complies120 One - <0.5% HCl >60% Complies150 One - <0.5% HCl >60% Complies185 One - <0.5% HCl >60% Complies240 One - <0.5% HCl >60% Complies300 One - <0.5% HCl >60% Complies400 One - <0.5% HCl >60% Complies500 One - <0.5% HCl >60% Complies630 One - <0.5% HCl >60% Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.

Page 460: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

450 31 Dec 2012

4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950oC and at a voltage rating of 600V.

Certificate No: 782f to BS 6387: 1994, IEC 60331-21: 1999, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

Ducab Flam BICC 3Nominal csa of

conductor (mm²)Core construction

(See note 1)BS 6387

(See notes 2 - 4)BS50267-2-1 BS61034-2 IEC 60331-21

(See note 8)LPCB Ref. No.

1.5 One C, W, Z(5) <0.5% HCl >60% Complies 782f/012.5 One C, W, Z(5) <0.5% HCl >60% Complies4.0 One C, W, Z(6,7) <0.5% HCl >60% Complies6.0 One C, W, Z(6,7) <0.5% HCl >60% Complies10 One C, W, Z(6,7) <0.5% HCl >60% Complies16 One C, W, Z(6,7) <0.5% HCl >60% Complies25 One C, W, Z(6,7) <0.5% HCl >60% Complies35 One C, W, Z(6,7) <0.5% HCl >60% Complies50 One C, W, Z(6,7) <0.5% HCl >60% Complies70 One C, W, Z(6,7) <0.5% HCl >60% Complies95 One C(7) <0.5% HCl >60% Complies120 One C(7) <0.5% HCl >60% Complies150 One C(7) <0.5% HCl >60% Complies185 One C(7) <0.5% HCl >60% Complies240 One C(7) <0.5% HCl >60% Complies300 One C(7) <0.5% HCl >60% Complies400 One C(7) <0.5% HCl >60% Complies500 One - <0.5% HCl >60% Complies630 One - <0.5% HCl >60% Complies

Uo/U 600/1000V

Notes:!) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950oC and at a voltage rating of 600V.

Certificate No: 408f-(cl-1) to BS 7629-1: 2008, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

Ducab Flam BICC 2Nominal csa of

conductor (mm²)Core construction

(excluding earth wire)BS 7629-1 BS EN 50200 BS EN 50200

Annex EBS 5839-1

Clause 26.2LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5) 408f/011.5(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

2.5(2) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

4.0(2) 2 Complies(3) Class PH30 30min(4) Standard(5)

Uo/U 300/500V

Notes:

1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Ducab Flam BICC 2 cables listed met the requirements of smoke density of BS

EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

Page 461: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 451

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002+A2:2008.

5) The Ducab Flam BICC 2 cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 408g-(cl-1) to BS 7629-1: 1997. This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU). BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

Ducab Flam BICC 2Nominal csa of

conductor (mm²)Core construction

(excluding earth wire)BS 7629-1

(see note 6)BS EN 50200 BS EN 50200

Annex EBS 5839-1

Clause 26.2LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5) 408g/011.5(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

2.5(2) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

4.0(2) 2 Complies(3) Class PH30 30min(4) Standard(5)

Uo/U 300/500V

Notes:

1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997, the Ducab Flam BICC 2 cables listed met the requirements of smoke density of BS

EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002+A2:2008.

5) The Ducab Flam BICC 2 cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

6) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 408f-(cl-1) covers cables certified in accordance with BS 7629-1: 2008

Eland Cables120 Highgate Studios, 53-79 Highgate Road, London NW5 1TL, United KingdomTel: +44 (0)20 7241 8787 • Fax: +44 (0)20 7241 8700E-mail: [email protected] • Website: www.eland.co.uk

Certificate No: 568c-(cl-1) to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

FireForceNominal csa of

conductor (mm²)

Core Construction

(excluding drainwire & earth)

BS 7629-1(Incorporating Amendments

Nos. 1 & 2)

BS EN 50200

BS 8434-1

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5) 568c/011.5(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

Notes:1) Solid and Stranded conductors.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FireForce cables listed met the

requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002.

Page 462: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

452 31 Dec 2012

5) The FireForce cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Emirates Fire Fighting Equipment Factory L.L.C. (FIREX)P.O.Box 22436, Industrial Area 13, Sharjah, United Arab EmiratesTel: +971 6 5340300 • Fax: +971 6 5340090E-mail: [email protected] • Website: www.firexuae.com

Certificate No: 568a-(cl-3) to BS 6387: 1994 and BS EN 50267-2-1: 1999

FIREXNominal csa of

conductors (mm²)Core Construction BS 6387 BS EN 50267-2-1

(outer covering)LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z <0.5%HCI 568a/011.5(1) 2, 3 & 4 C, W, Z <0.5%HCI2.5(1) 2, 3 & 4 C, W, Z <0.5%HCI4.0(2) 2, 3 & 4 C, W, Z <0.5%HCI

Uo/U 300/500 V

Notes:1) Solid and stranded conductors.2) Stranded conductor only.

Certificate No: 568a-(cl-3) to BS 6387: 1994 and BS EN 50267-2-1: 1999

FIREX-UKNominal csa of

conductors (mm²)Core Construction BS 6387 BS EN 50267-2-1

(outer covering)LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z <0.5%HCI 568a/011.5(1) 2, 3 & 4 C, W, Z <0.5%HCI2.5(1) 2, 3 & 4 C, W, Z <0.5%HCI4.0(2) 2, 3 & 4 C, W, Z <0.5%HCI

Uo/U 300/500 V

Notes:1) Solid and stranded conductors.2) Stranded conductor only.

Certificate No: 711c-(cl-3) to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

Tornado FE180 PH30Nominal csa of

conductors (mm²)Core construction drain wire & earth)

BS 6387 BS EN 50200 LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z Class PH30 711c/011.5(1) 2, 3 & 4 C, W, Z Class PH302.5(1) 2, 3 & 4 C, W, Z Class PH30

Uo/U 300/500V

Note: 1) Solid conductor only.

Certificate No: 711c-(cl-4) to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

2S Cables FE180 PH30Nominal csa of

conductors (mm²)Core construction

(excluding drain wire & earth)BS 6387 BS EN 50200 LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z Class PH30 711c/011.5(1) 2, 3 & 4 C, W, Z Class PH302.5(1) 2, 3 & 4 C, W, Z Class PH30

Page 463: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 453

Uo/U 300/500V

Note:1) Solid conductor only.

Fireguard Safety Equipment Co Ltd2nd Floor, 145-147 St John Street, London EC1V 4PY, United KingdomTel: +44 (0)8450 751042 • Fax: +44 (0)845 2991039E-mail: [email protected] • Website: www.fireguard-uk.com

Certificate No: 711c-(cl-2) to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

Fireguard-UK FG FRC 180 PH30Nominal csa of

conductors (mm²)Core construction

(excluding drain wire & earth)BS 6387 BS EN 50200 LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z Class PH30 711c/011.5(1) 2, 3 & 4 C, W, Z Class PH302.5(1) 2, 3 & 4 C, W, Z Class PH30

Uo/U 300/500V

Note:1) Solid conductor only.

Grupo General Cable Sistemas, S.A.CTRA. Rusinol, 63., 08560, Manlleu, SpainTel: +34 93 852 02 00 • Fax: +34 93 852 02 22E-mail: [email protected] • Website: www.generalcable.es

Certificate No: 722a to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50268-2: 2000 and IEC 60331-21: 1999

SEGURFOC FR 950 07Z-R-MNominal csa of

conductor (mm2)Core

Construction(see note 1)

BS 6387 BS EN 50267-2-1(insulation & Binder tape)

BS EN 50268-2 IEC 60331-21(see note 7)

LPCB Ref. No.

1.5 one (3,4) C, W, Z <0.5%HCI >60% Complies 722a/012.5 one (4,5,6) C, W, Z <0.5%HCI >60% Complies4.0 one (4,5,6) C, W, Z <0.5%HCI >60% Complies6.0 one (4,5,6) C, W, Z <0.5%HCI >60% Complies10 one (4,5,6) C, W, Z <0.5%HCI >60% Complies16 one (4,5,6) C, W, Z <0.5%HCI >60% Complies25 one (2,5,6) C, W <0.5%HCI >60% Complies35 one (2,5,6) C, W <0.5%HCI >60% Complies50 one (2,5,6) C, W <0.5%HCI >60% Complies70 one (2,5,6) C, W <0.5%HCI >60% Complies95 one (2,5,6) C, W <0.5%HCI >60% Complies120 one (2,5,6) C, W <0.5%HCI >60% Complies150 one (2,5,6) C, W <0.5%HCI >60% Complies185 one (2,6) C <0.5%HCI >60% Complies240 one (2,6) C <0.5%HCI >60% Complies300 one (2,6) C <0.5%HCI >60% Complies400 one (2,6) C <0.5%HCI >60% Complies500 one (2,6) C <0.5%HCI >60% Complies

Uo/U 450/750V

Notes:1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core.2) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.

Page 464: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

454 31 Dec 2012

3) To satisfy the requirement of BS 6387, testing for C & W categories was conducted using a 20mm stainless steel conduit as the other metallic element.

4) To satisfy the requirement of BS 6387, testing for Z category was conducted using a 20mm stainless steel conduit as the other metallic element.

5) To satisfy the requirement of BS 6387, testing for W category was conducted using a 38mm stainless steel conduit as the other metallic element.

6) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other metallic element.

7) Testing to IEC 60331-21: 1999 was conducted at 450V.

Certificate No: 722b to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

GENFIRE ALARMNominal csa of

conductor (mm²)

Core construction(excluding drain wire &

earth)

BS 7629-1 BS 6387

BS EN 50200

BS EN 50200

Annex E

BS 5839-1 Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) C,W,Z Class PH30 30min(4) Standard(5) 722b/011.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH30 30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH30 30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) C,W,Z Class PH30 30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the GENFIRE ALARM cables listed met the requirements of smoke density of BS

EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The GENFIRE ALARM cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Grupo General Cable Sistemas, S.A.CTRA. DE RIBAS KM 13.250, Montcada I Reixac, 08110, Barcelona, SpainTel: +34 93 227 95 00 • Fax: +34 93 227 95 22E-mail: [email protected] • Website: www.generalcable.es

Certificate No: 730a to BS 7846: 2000 (Incorporating Amendment Nos 1 and 2)

SEGURFOC FRA 950Nominal csa of

conductor (mm2)Core

ConstructionBS 7846

(see note 2)LPCB Ref. No.

1.5(1) 2, 3 & 4 F2 730a/012.5(1) 2, 3 & 4 F24.0(1) 2, 3 & 4 F26.0(1) 2, 3 & 4 F210(1) 2, 3 & 4 F216(1) 2, 3 & 4 F225(1) 2, 3 & 4 F235(1) 2, 3 & 4 F250(1) 2, 3 & 4 F270(1) 2, 3 & 4 F295(1) 2, 3 & 4 F2

120(1) 2, 3 & 4 F2150(1) 2, 3 & 4 F2185(1) 2, 3 & 4 F2

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) In meeting the requirements of BS 7846 Category F2, the SEGURFOC FRA 950 cable met the requirements for fire

Page 465: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 455

resistance characteristics category CWZ specified in Clause 11 of BS 6387.

Certificate No: 730a to BS 7846: 2000 (Incorporating Amendment Nos 1 and 2)

SEGURFOC FRA-1 950Nominal csa of

conductor (mm2)Core

ConstructionBS 7846

(see note 2)LPCB Ref. No.

240(1) 2, 3 & 4 F2 730a/02300(1) 2, 3 & 4 F2400(1) 2, 3 & 4 F2

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) In meeting the requirements of BS 7846 Category F2, the SEGURFOC FRA-1 950 cable met the requirements for fire resistance

characteristics category CWZ specified in Clause 11 of BS 6387.

Huzhou Jiusheng Electric Co Ltd1000 Xifeng Road, Huzhou Economy & Technology Area, Huzhou, Zhejiang, ChinaTel: +86 572 222 8188 • Fax: +86 572 222 8177E-mail: zjh@hz-tec • Website: www.teccable.com

Certificate No: 948a to BS EN 60702-1: 2002 and BS 6387: 1994

TEC MI BARE CABLE (LIGHT DUTY)Nominal csa of conductor (mm²) Core Construction BS EN 60702-1 BS 6387 LPCB Ref. No.

1.0(1,2) 2, 3, 4 & 7 Complies C,W,Z 948a/011.5(1,2) 2, 3, 4 & 7 Complies C,W,Z2.5(1,2) 2, 3, 4 & 7 Complies C,W,Z4.0(1,2) 2 Complies C,W,Z

Uo/U 300/500V

Notes:1) Solid conductor only.2) The above cables are certified in Bare construction only.

Certificate No: 948b to BS 60702-1: 2002, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120, BS 8343-2: 2003+A2:2009 120min and BS EN 50267-2-1: 1999

TEC MI SERVED CABLE (LIGHT DUTY)Nominal csa of

conductor (mm²)

Core Construction

BS EN 60702-1 (see

note 3)

BS 6387

BS EN 50200

BS 8434-2

BS 5839-1 Clause 26.2

BS EN 50267-2-1 (outer covering)

LPCB Ref. No.

1.0(1,2) 2, 3, 4 & 7 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl 948b/01

1.5(1,2) 2, 3, 4 & 7 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl

2.5(1,2) 2, 3, 4 & 7 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl

4.0(1,2) 2 Complies C,W,Z Class PH120

120min Enhanced(4) <0.5% HCl

Uo/U 300/500V

Notes:1) Solid conductor only.2) The above cables are certified in Served construction only.3) In meeting the requirements of BS EN 60702-1: 2002, the TEC MI SERVED CABLE (LIGHT DUTY) listed met the requirements of

smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997.

Page 466: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

456 31 Dec 2012

4) The TEC MI SERVED CABLE (LIGHT DUTY) listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Irish Driver-Harris Company LimitedMillbanks, New Ross, Co. Wexford, IrelandTel: +353 51 421 405 • Fax: +353 51 422 983E-mail: [email protected] • Website: www.idh.ie

Certificate No: 408a to BS 7629-1:1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30, BS8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

Kilflam 2000Nominal csa of

conductor (mm2)Core

Construction(excluding drain

wire & earth)

BS 7629-1(IncorporatingAmendments

Nos.1 & 2)

BS EN 50200 BS 8434-1 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7) 408a/011.5(2,3) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7)

2.5(4) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7)

4.0(4) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Solid conductor at 3 & 4 cores only.3) Stranded conductor at 2 core only.4) Stranded conductor only.5) In meeting the requirements of BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), the Kilflam 2000 cables met the

requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCI on the (outer covering, insulation and binder tape) when tested in accordance with BS EN 50267-2-1: 1999.

6) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1:2002.

7) The Kilflam 2000 cables listed conform to BS 7629-1:1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200:2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1:2002.

Certificate No: 408b to BS 6387: 1994

Kilflam 1000Nominal csa of

conductor (mm2)Core

ConstructionBS 6387 LPCB Ref. No.

1.5 One C, W, Z 408b/012.5 One C, W, Z4.0 One C, W, Z6.0 One C, W, Z10.0 One C, W, Z16.0 One C, W, Z

Uo/U 450/750V

Notes:1) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable only having one core.2) To satisfy the requirements of BS 6387, testing for C, W and Z categories was conducted using 20mm steel conduit as the other

metallic element.

Certificate No: 408d to BS 6387: 1994 and BS EN 50267-2-1: 1999

Kilflam 1200Nominal csa of

conductor (mm2)Core

Construction(see note 1)

BS 6387(see notes 2, 3 & 7)

BS EN 50267-2-1(outer covering)

LPCB Ref. No.

1.5 One(4,6) C, W, Z <0.5%HCl 408d/01

Page 467: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 457

Nominal csa ofconductor (mm2)

CoreConstruction(see note 1)

BS 6387(see notes 2, 3 & 7)

BS EN 50267-2-1(outer covering)

LPCB Ref. No.

2.5 One(4,6) C, W, Z <0.5%HCl4.0 One(4,6) C, W, Z <0.5%HCl6.0 One(5,6) C, W, Z <0.5%HCl

10.0 One(5,6) C, W, Z <0.5%HCl

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core.3) The Kilflam 1200 cable also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 20mm steel conduit as the other metallic

element.5) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic

element.6) To satisfy the requirement of BS 6387, testing for W and Z categories was conducted using a 20mm steel conduit as the other

metallic element.7) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.

Certificate No: 408e to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

Kilflam 2000Nominal csa of

conductor (mm²)Core

Construction(excluding drain

wire & earth)

BS 7629-1(see note 8)

BS EN 50200 BS 8434-1 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7) 408e/011.5(2,3) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7)

2.5(4) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7)

4.0(4) 2, 3 & 4 Complies(5) Class PH30 30min(6) Standard(7)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Solid conductor at 3 & 4 cores only.3) Stranded conductor at 2 core only.4) Stranded conductor only5) In meeting the requirements of BS 7629-1: 1997, the Kilflam 2000 cables listed met the requirements of smoke density of BS EN

50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999.

6) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002.

7) The Kilflam 2000 cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

8) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 408a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2)

Certificate No: 408b-(cl-1) to BS 6387: 1994

Fumeguard FRNominal csa of

conductor (mm²)Core construction BS 6387

(see notes 1 & 2)LPCB Ref. No.

1.5 One C, W, Z 408b/012.5 One C, W, Z4.0 One C, W, Z6.0 One C, W, Z

Page 468: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

458 31 Dec 2012

Nominal csa ofconductor (mm²)

Core construction BS 6387(see notes 1 & 2)

LPCB Ref. No.

10.0 One C, W, Z16.0 One C, W, Z

Uo/U 450/750V

Notes:1) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) can not be conducted due to the cable having only one core.2) To satisfy the requirement of BS 6387, testing for C, W, and Z categories was conducted using 20mm steel conduit as the other

metallic element.

Certificate No: 408f to BS 7629-1: 2008, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E 30min and BS 5839-1: 2002+A2:2008 Clause 26.2d

Kilflam Standard 2000Nominal csa of

conductor (mm²) Core construction

(excluding earth wire)BS 7629-1 BS EN 50200 BS EN 50200

Annex EBS 5839-1

Clause 26.2LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5) 408f/011.5(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

2.5(2) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

4.0(2) 2 Complies(3) Class PH30 30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Kilflam Standard 2000 cables listed met the requirements of smoke density of

BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (outer covering, binder tape & insulation) when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002+A2:2008.

5) The Kilflam Standard 2000 cables listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 408g to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

Kilflam Standard 2000Nominal csa of

conductor (mm²) Core construction

(excluding earth wire)BS 7629-1

(see note 6)BS EN 50200 BS EN 50200

Annex EBS 5839-1

Clause 26.2LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5) 408g/011.5(1) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

2.5(2) 2, 3 & 4 Complies(3) Class PH30 30min(4) Standard(5)

4.0(2) 2 Complies(3) Class PH30 30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997, the Kilflam Standard 2000 cables listed met the requirements of smoke density of

BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002+A2:2008.

5) The Kilflam Standard 2000 cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 408h to BS 7846: 2009 Category F2

Page 469: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 459

Kilflam 4000 SWANominal csa of

conductor (mm²)Core construction

(see note 1)BS 7846 LPCB Ref. No.

1.5 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 F2(2) 408h/012.5 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 F2(2)

4.0 2, 3, 4, 5, 7, 12, 19, 27, 37 & 48 F2(2)

6.0 2, 3, 4 & 5 F2(2)

10 2, 3, 4 & 5 F2(2)

16 2, 3, 4 & 5 F2(2)

Uo/U 600/1000V

Notes:1) Stranded conductors only.2) In meeting the requirements of BS 7846: 2009 Category F2, the Kilflam 4000 SWA cables listed met the requirements for fire

resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994.

Certificate No: 408j to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009

Kilflam 3000Nominal csa of

conductor (mm²)Core construction (excluding drain

wire & earth)

BS 7629-1 BS EN 50200 BS 8434-2 BS 5839-1 Clause 26.2 LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(4) Class PH120 120min(5) Enhanced(6) 408j/011.5(1) 2, 3 & 4 Complies(4) Class PH120 120min(5) Enhanced(6)

2.5(2) 2, 3 & 4 Complies(4) Class PH120 120min(5) Enhanced(6)

4.0(3) 2, 3 & 4 Complies(4) Class PH120 120min(5) Enhanced(6)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Solid & Stranded conductors.3) Stranded conductor only.4) In meeting the requirements of BS 7629-1: 2008, the Kilflam 3000 cables listed met the requirements of smoke density of BS EN

61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

5) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

6) The Kilflam 3000 cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 408k to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

Kilflam 1000 aNominal csa of

conductor (mm²)Core construction

(See note 1)BS 6387

(See notes 2-4)BS EN 50267-2-1(Outer covering)

IEC 60331-21(See notes 8 & 9)

LPCB Ref. No.

1.0 One C,W,Z(5) <0.5%HCl Complies 408k/011.5 One C,W,Z(5) <0.5%HCl Complies2.5 One C,W,Z(5) <0.5%HCl Complies4.0 One C,W,Z(5) <0.5%HCl Complies6.0 One C,W,Z(5) <0.5%HCl Complies10 One C,W,Z(5) <0.5%HCl Complies16 One C,W,Z(6,7) <0.5%HCl Complies25 One C,W,Z(6,7) <0.5%HCl Complies35 One C,W,Z(6,7) <0.5%HCl Complies50 One C(7) <0.5%HCl Complies70 One C(7) <0.5%HCl Complies95 One C(7) <0.5%HCl Complies120 One C(7) <0.5%HCl Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.

Page 470: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

460 31 Dec 2012

4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950ºC and at a voltage rating of 600V.9) The Kilflam 1000 a cable also met IEC 60331-21: 1999 when installed in steel conduit.

Certificate No: 408m to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

Fumeguard FR aNominal csa of

conductor (mm²)Core construction

(See note 1)BS 6387

(See notes 2-4)BS EN 50267-2-1(Outer covering)

IEC 60331-21(See notes 8 & 9)

LPCB Ref. No.

1.0 One C,W,Z(5) <0.5%HCl Complies 408m/011.5 One C,W,Z(5) <0.5%HCl Complies2.5 One C,W,Z(5) <0.5%HCl Complies4.0 One C,W,Z(5) <0.5%HCl Complies6.0 One C,W,Z(5) <0.5%HCl Complies10 One C,W,Z(5) <0.5%HCl Complies16 One C,W,Z(6,7) <0.5%HCl Complies25 One C,W,Z(6,7) <0.5%HCl Complies35 One C,W,Z(6,7) <0.5%HCl Complies50 One C(7) <0.5%HCl Complies70 One C(7) <0.5%HCl Complies95 One C(7) <0.5%HCl Complies120 One C(7) <0.5%HCl Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950ºC and at a voltage rating of 600V.9) The Fumeguard FR a cable also met IEC 60331-21: 1999 when installed in steel conduit.

Jaylow Supplies LtdJaylow House, Leyton Link Estate, Argall Avenue, Leyton, London E10 7FD, United KingdomTel: +44 (0)870 444 6890 • Fax: +44 (0)870 444 6891Website: www.jaylowcables.com

Certificate No: 682a-(cl-1) to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN50200: 2006 Annex E and BS 5839-1:2002+A2: 2008 Clause 26.2d

JayflameNominal csa of

conductor (mm2)Core

Construction(excluding drain

wire & earth)

BS 7629-1 BS EN 50200 BS EN 50200Annex E

BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5) 682a/011.5(1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.

Page 471: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 461

2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Jayflame cables listed met the requirements of smoke density of BS EN 61034-

2: 2005 fire resistance requirements CWZ in Clause 11 of BS 6387:1994 and achieved less than 0.5%HCl on the insulation, bindertape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The Jayflame cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2: 2008.

Keystone Electric Wire & Cable Company Ltd#110 DD 83, Kwan Ti North Village, Fanling, New Territories, Hong KongTel: +852 2691 7183 • Fax: +852 2695 9738E-mail: [email protected] • Website: www.keystonecable.com

Manufacturing at:Dongguan Keystone Electric Wire & Cable Co Ltd, Ye Sha Management District,, Shatin, Dongguan City, Guangdong, ChinaTel: +86 769 8886 1814 • Fax: +86 769 8886 1696E-mail: [email protected]

Sales Office:Tel: +852 2691 7183 • Fax: +852 2695 9738E-mail: [email protected] • Website: www.keystonecable.com

Certificate No: 663b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and IEC 60331-21: 1999

KEYSTONE FR 7211 CableNominal csa of

conductor (mm2)Core

Construction(see note 1)

BS 6387 (see note 2-3)

BS EN 50267-2-1 BS EN 61034-2 IEC 60331-21 LPCB Ref. No.

1.5 One C,W,Z(4) <0.5% HCI >60% Complies 663b/012.5 One C,W,Z(4) <0.5% HCI >60% Complies4.0 One C,W,Z(4) <0.5% HCI >60% Complies6.0 One C,W,Z(4) <0.5% HCI >60% Complies10 One C,W,Z(4) <0.5% HCI >60% Complies16 One C,W,Z(5,6) <0.5% HCI >60% Complies25 One C,W,Z(5,6) <0.5% HCI >60% Complies35 One C,W,Z(5,6) <0.5% HCI >60% Complies50 One C(7) <0.5% HCI - Complies70 One C(7) <0.5% HCI - Complies95 One C(7) <0.5% HCI - Complies120 One C(7) <0.5% HCI - Complies150 One C(7) <0.5% HCI - Complies185 One C(7) <0.5% HCI - Complies240 One C(7) <0.5% HCI - Complies300 One C(7) <0.5% HCI - Complies

Uo/U 450/750V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core. 3) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.4) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm steel conduit as the other

metallic element.5) To satisfy the requirement of BS 6387, testing for Z category was conducted using a 20mm steel conduit as the other metallic

element.6) To satisfy the requirement of BS 6387, testing for C & W category was conducted using a 38mm steel conduit as the other metallic

element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic

element.

Page 472: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

462 31 Dec 2012

Manufacturing at:Dongguan Keystone Electric Wire & Cable Co Ltd, Ye Sha Management District,, Shatin, Dongguan City, Guangdong, ChinaTel: +86 769 8886 1814 • Fax: +86 769 8886 1696E-mail: [email protected]

Sales Office:Tel: +852 2691 7183 • Fax: +852 2695 9738E-mail: [email protected] • Website: www.keystonecable.com

Certificate No: 663c to BS 7846: 2009

KEYSTONE Fire Resistance Armoured CableNominal csa of

conductor (mm2)Core Construction (see note 1) BS 7846 LPCB Ref. No.

1.5 2, 3 & 4 F2(2) 663c/012.5 2, 3 & 4 F2(2)

4.0 2, 3 & 4 F2(2)

6.0 2, 3 & 4 F2(2)

10 2, 3 & 4 F2(2)

16 2, 3 & 4 F2(2)

25 2, 3 & 4 F2(2)

35 2, 3 & 4 F2(2)

50 2, 3 & 4 F2(2)

70 2, 3 & 4 F2(2)

95 2, 3 & 4 F2(2)

120 2, 3 & 4 F2(2)

150 2, 3 & 4 F2(2)

185 2, 3 & 4 F2(2)

240 2, 3 & 4 F2(2)

300 2, 3 & 4 F2(2)

400 2, 3 & 4 F2(2)

Uo/U 600/1000V

Note:1) Stranded conductors only.2) In meeting the requirements of BS 7846: 2009, the KEYSTONE Fire Resistance Armoured Cables listed met the requirements for fire

resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994.

KME Italy SpAVia Della Repubblica 257, 55051 Fornaci Di Barga, Lucca, ItalyTel: +39 0583 701.1 • Fax: +39 0583 701623E-mail: [email protected] • Website: www.kme-italy.com

Certificate No: 427a to BS 6387: 1994 and BS EN 60702-1: 2002

MICO - KME Light duty Mineral Insulated CableNominal csa

of conductor (mm2)Core Construction

(see note 1)BS 6387 BS EN 60702-1 LPCB Ref. No.

1.0 2, 3, 4 & 7 C, W, Z Complies 427a/011.5 2, 3, 4 & 7 C, W, Z Complies2.5 2, 3, 4 & 7 C, W, Z Complies4.0 2 C, W, Z Complies

Uo/U 300/500V

Note:1) The above range is certified in both Bare and Served constructions.

Page 473: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 463

Certificate No: 427a to BS 6387: 1994 and BS EN 60702-1: 2002

MICO - KME Single core heavy duty mineral insulated cablesNominal csa

of conductor (mm2)Core Construction

(see note 1)BS 6387

(see note 2)BS EN 60702-1 LPCB Ref. No.

1.5 One C, W, Z Complies 427a/022.5 One C, W, Z Complies4.0 One C, W, Z Complies6.0 One C, W, Z Complies10 One C, W, Z Complies16 One C, W, Z Complies25 One C, W, Z Complies35 One C, W, Z Complies50 One C, W, Z Complies70 One C, W, Z Complies95 One C, W, Z Complies

120 One C, W, Z Complies150 One C, W, Z Complies185 One C, W, Z Complies240 One C, W, Z Complies300 One C, W, Z Complies400 One C, W, Z Complies

Uo 750V

Notes:1) The above range is certified in both Bare and Served constructions.2) For cable with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the

manufacturer.

Certificate No: 427a to BS 6387: 1994 and BS EN 60702-1: 2002

MICO - KME Multi-core heavy duty mineral insulated cablesNominal csa

of conductor (mm2)Core Construction

(see note 1)BS 6387

(see note 2)BS EN 60702-1 LPCB Ref. No.

1.5 2, 3, 4, 7, 12 & 19 C, W, Z Complies 427a/032.5 2, 3, 4, 7 & 12 C, W, Z Complies4.0 2, 3 & 4 C, W, Z Complies6.0 2, 3 & 4 C, W, Z Complies10 2, 3 & 4 C, W, Z Complies16 2, 3 & 4 C, W, Z Complies25 2, 3 & 4 C, W, Z Complies

Uo/U 450/750V

Notes: 1) The above range is certified in both Bare and Served constructions.2) For cables with an outside diameter in excess of 20mm, the category Z tests were conducted in accordance with guidance from the

manufacturer.

LEONI Studer AGHerrenmattstr. 20, CH 4658 Däniken, SwitzerlandTel: +41 62 288 82 82 • Fax: +41 62 288 83 83E-mail: [email protected] • Website: www.leoni-infrastructure.com

Certificate No: 896a to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 90 Cable Single Core SlNominal csa

of conductor

(mm 2)

Core Construction (see note 1)

BS 6387 (see notes 2-4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 9)

IEC 60332-3-24

LPCB Ref. No.

1.5 one C,W,Z (5) <0.5%HCI >60% Complies Complies 896a/01

Page 474: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

464 31 Dec 2012

Nominal csa of

conductor (mm 2)

Core Construction (see note 1)

BS 6387 (see notes 2-4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 9)

IEC 60332-3-24

LPCB Ref. No.

2.5 one C,W,Z (5) <0.5%HCI >60% Complies Complies4.0 one C,W,Z (5) <0.5%HCI >60% Complies Complies6.0 one C,W,Z (5) <0.5%HCI >60% Complies Complies10 one C,W,Z (5) <0.5%HCI >60% Complies Complies16 one C,W,Z (5) <0.5%HCI >60% Complies Complies25 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies35 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies50 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies70 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies95 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies120 one C(7) <0.5%HCI >60% Complies Complies150 one C(7) <0.5%HCI >60% Complies Complies185 one C(7) <0.5%HCI >60% Complies Complies240 one C(7) <0.5%HCI >60% Complies Complies300 one C(7) <0.5%HCI >60% Complies Complies400 one C(7) <0.5%HCI >60% Complies Complies500 one Complies(8) <0.5%HCI >60% Complies Complies630 one Complies(8) <0.5%HCI >60% Complies Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) Only Clause 10 of BS 6387 was conducted.9) The BETAflam FR-MI 90 Cable Single Core SI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of

950°C and at a voltage rating of 600V.

Certificate No: 896a to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 90 Cable Single Core DINominal csa

of conductor

(mm 2)

Core Construction (see note 1)

BS 6387 (see notes 2-4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 9)

IEC 60332-3-24

LPCB Ref. No.

1.5 one C,W,Z (5) <0.5%HCI >60% Complies Complies 896a/02

2.5 one C,W,Z (5) <0.5%HCI >60% Complies Complies4.0 one C,W,Z (5) <0.5%HCI >60% Complies Complies6.0 one C,W,Z (5) <0.5%HCI >60% Complies Complies10 one C,W,Z (5) <0.5%HCI >60% Complies Complies16 one C,W,Z (5) <0.5%HCI >60% Complies Complies25 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies35 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies50 one C,W,Z (6,7) <0.5%HCI >60% Complies Complies70 one C(7) <0.5%HCI >60% Complies Complies95 one C(7) <0.5%HCI >60% Complies Complies120 one C(7) <0.5%HCI >60% Complies Complies150 one C(7) <0.5%HCI >60% Complies Complies185 one C(7) <0.5%HCI >60% Complies Complies240 one C(7) <0.5%HCI >60% Complies Complies300 one C(7) <0.5%HCI >60% Complies Complies400 one Complies(8) <0.5%HCI >60% Complies Complies500 one Complies(8) <0.5%HCI >60% Complies Complies630 one Complies(8) <0.5%HCI >60% Complies Complies

Uo/U 600/1000V

Page 475: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 465

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) Only Clause 10 of BS 6387 was conducted.9) The BETAflam FR-MI 90 Cable Single Core DI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of

950°C and at a voltage rating of 600V.

Certificate No: 896b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Single Core SINominal csa

of conductor

(mm 2)

Core Construction (see note 1)

BS 6387 (see notes 2-4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 9)

IEC 60332-3-24

LPCB Ref. No.

1.5 one C,W,Z(5) <0.5%HCI >60% Complies Complies 896b/012.5 one C,W,Z(5) <0.5%HCI >60% Complies Complies4.0 one C,W,Z(5) <0.5%HCI >60% Complies Complies6.0 one C,W,Z(5) <0.5%HCI >60% Complies Complies10 one C,W,Z(5) <0.5%HCI >60% Complies Complies16 one C,W,Z(5) <0.5%HCI >60% Complies Complies25 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies35 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies50 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies70 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies95 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies120 one C(7) <0.5%HCI >60% Complies Complies150 one C(7) <0.5%HCI >60% Complies Complies185 one C(7) <0.5%HCI >60% Complies Complies240 one C(7) <0.5%HCI >60% Complies Complies300 one C(7) <0.5%HCI >60% Complies Complies400 one C(7) <0.5%HCI >60% Complies Complies500 one Complies(8) <0.5%HCI - Complies Complies630 one Complies(8) <0.5%HCI - Complies Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) Only Clause 10 of BS 6387 was conducted.9) The BETAflam FR-MI 110 Cable Single Core SI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of

950°C and at a voltage rating of 600V.

Certificate No: 896b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Single Core DINominal csa

of conductor

(mm 2)

Core Construction (see note 1)

BS 6387 (see notes 2-4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 9)

IEC 60332-3-24

LPCB Ref. No.

1.5 one C,W,Z(5) <0.5%HCI >60% Complies Complies 896b/022.5 one C,W,Z(5) <0.5%HCI >60% Complies Complies

Page 476: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

466 31 Dec 2012

Nominal csa of

conductor (mm 2)

Core Construction (see note 1)

BS 6387 (see notes 2-4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 9)

IEC 60332-3-24

LPCB Ref. No.

4.0 one C,W,Z(5) <0.5%HCI >60% Complies Complies6.0 one C,W,Z(5) <0.5%HCI >60% Complies Complies10 one C,W,Z(5) <0.5%HCI >60% Complies Complies16 one C,W,Z(5) <0.5%HCI >60% Complies Complies25 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies35 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies50 one C,W,Z(6,7) <0.5%HCI >60% Complies Complies 70 one C(7) <0.5%HCI >60% Complies Complies95 one C(7) <0.5%HCI >60% Complies Complies120 one C(7) <0.5%HCI >60% Complies Complies150 one C(7) <0.5%HCI >60% Complies Complies185 one C(7) <0.5%HCI >60% Complies Complies240 one C(7) <0.5%HCI >60% Complies Complies300 one C(7) <0.5%HCI >60% Complies Complies400 one Complies(8) <0.5%HCI - Complies Complies500 one Complies(8) <0.5%HCI - Complies Complies630 one Complies(8) <0.5%HCI - Complies Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) Only Clause 10 of BS 6387 was conducted.9) The BETAflam FR-MI 110 Cable Single Core DI cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of

950°C and at a voltage rating of 600V.

Certificate No: 896c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable MulticoreNominal csa

of conductor

(mm 2)

Core Construction (see note 1)

BS 6387 (see note

2)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 3)

IEC 60332-3-24

LPCB Ref. No.

1.5 2, 3, 4, 5, 6, 7, 8, 10, 14, 19, 21, 24, 27, 33, 37 & 41

C,W,Z <0.5%HCI >60% Complies Complies 896c/01

2.5 2, 3, 4, 5, 7, 10, 12, 14, 16, 19, 21 & 24

C,W,Z <0.5%HCI >60% Complies Complies

4.0 2, 3, 4, 5, 6 & 7 C,W,Z <0.5%HCI >60% Complies Complies6.0 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies10 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies16 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies25 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies35 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies50 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies70 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies95 2, 3, 4 & 5 C,W,Z <0.5%HCI - Complies Complies

120 3 & 4 C,W,Z <0.5%HCI - Complies Complies150 3 & 4 C,W,Z <0.5%HCI - Complies Complies185 3 & 4 C,W,Z <0.5%HCI - Complies Complies240 3 & 4 C,W,Z <0.5%HCI - Complies Complies300 3 & 4 C,W,Z <0.5%HCI - Complies Complies400 3 & 4 C,W,Z <0.5%HCI - Complies Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.

Page 477: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 467

2) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.3) The BETAflam FR-MI 110 Cable Multicore cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of

950°C and at a voltage rating of 600/1000V.

Certificate No: 896c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Multicore STANominal csa

of conductor

(mm 2)

Core Construction (see note 1)

BS 6387 (see note 2)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 4)

IEC 60332-3-24

LPCB Ref. No.

1.5 2, 3, 4, 5, 7, 10, 19, 21 & 41

C,W,Z <0.5%HCI >60% Complies Complies 896c/02

2.5 2, 3, 4, 5, 7, 10 & 21 C,W,Z <0.5%HCI >60% Complies Complies4.0 2, 3, 4, 5 & 7 C,W,Z <0.5%HCI >60% Complies Complies6.0 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Comlies Complies10 2, 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies16 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies25 3, 4 & 5 C,W,Z <0.5HCI >60% Complies Complies

35(3) 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies50 3 & 4 C,W,Z <0.5%HCI - Complies Complies70 3 & 4 C,W,Z <0.5%HCI - Complies Complies95 3 & 4 C,W,Z <0.5%HCI - Complies Complies120 3 & 4 C,W,Z <0.5%HCI - Complies Complies150 3 & 4 C,W,Z <0.5%HCI - Complies Complies185 3 & 4 C,W,Z <0.5%HCI - Complies Complies240 3 & 4 C,W,Z <0.5%HCI - Complies Complies300 3 & 4 C,W,Z <0.5%HCI - Complies Complies400 3 & 4 C,W,Z <0.5%HCI - Complies Complies

Uo/U 600/1000V

Notes: 1) Stranded conductor only.2) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 63873) BS EN 61034-2: 2005 approval applies to the 35mm2 cable at 3 & 4 cores only.4) The BETAflam FR-MI 110 Cable Multicore STA cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of

950oC and at a voltage rating of 600/1000V.

Certificate No: 896c to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Multicore SWANominal csa

of conductor

(mm 2)

Core Construction (see note 1)

BS 6387 (see note 2)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 3)

IEC 60332-3-24

LPCB Ref. No.

2.5 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies 896c/034.0 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies6.0 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies10 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies16 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies25 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies35 3, 4 & 5 C,W,Z <0.5%HCI >60% Complies Complies50 3 & 4 C,W,Z <0.5%HCI >60% Complies Complies70 3 & 4 C,W,Z <0.5%HCI - Complies Complies95 3 & 4 C,W,Z <0.5%HCI - Complies Complies120 3 & 4 C,W,Z <0.5%HCI - Complies Complies150 3 & 4 C,W,Z <0.5%HCI - Complies Complies185 3 & 4 C,W,Z <0.5%HCI - Complies Complies240 3 & 4 C,W,Z <0.5%HCI - Complies Complies300 3 & 4 C,W,Z <0.5%HCI - Complies Complies400 3 & 4 C,W,Z <0.5%HCI - Complies Complies

Uo/U 600/1000V

Notes1) Stranded conductor only.2) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.

Page 478: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

468 31 Dec 2012

3) The BETAflam FR-MI 110 Cable Multicore SWA cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950°C and at a voltage rating of 600/1000V.

Certificate No: 896d to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60331-21: 1999 and IEC 60332-3-24: 2000

BETAflam FR-MI 110 Cable Comms S/UTPNominal csa

of conductor

(mm 2)

Core Construction (excluding drain wire)

BS 6387

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21 (see note 3)

IEC 60332-3-24

LPCB Ref. No.

0.75(1) 1, 2, 3, 5, 7 & 10 pairs C,W,Z <0.5%HCI >60% Complies Complies 896d/011.0(1) 1, 2, 3, 5, 7 & 10 pairs C,W,Z <0.5%HCI >60% Complies Complies

1.5(1, 2) 1, 2, 3, 5, 7 & 10 pairs C,W,Z <0.5%HCI >60% Complies Complies2.5(1) 1, 2, 3, 5, 7 & 10 pairs C,W,Z <0.5%HCI - Complies Complies

Uo/U 300/500V

Notes:1) Stranded conductor only.2) BS EN 61034-2: 2005 approval applies to the 1.5mm2 cable at 1, 2 & 3 pairs only.3) The BETAflam FR-MI 110 Cable Comms S/UTP cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of

950°C and at a voltage rating of 300/500V.

Certificate No: 896e to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60332-3-22: 2008 and IEC 60332-3-24: 2008

BETAflam FR-SIR-F 90Nominal csa of

conductor (mm 2)

Coreconstruction

(excluding drain wire)

BS 6387

BS EN 50267-2-1

BS EN 61034-2

IEC 60332-3-22

IEC 60332-3-24

LPCB Ref. No.

1.5(1) 1 pair C,W,Z <0.5% HCl >60% Complies Complies 896e/012.5(1) 1 pair C,W,Z <0.5% HCl >60% Complies Complies

Uo/U 300/500V

Note 1: Solid conductor only.

Certificate No: 896f to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005, IEC 60332-3-22: 2008 and IEC 60332-3-24: 2008

BETAflam FR-SIR-U 90Nominal csa of

conductor (mm 2)

Coreconstruction

(excluding drain wire)

BS 6387

BS EN 50267-2-1

BS EN 61034-2

IEC 60332-3-22

IEC 60332-3-24

LPCB Ref. No.

2.5(1) 1 pair C,W,Z <0.5% HCl >60% Complies Complies 896f/01

Uo/U 300/500V

Note 1: Solid conductor only.

MICC (Shanghai) Electric Co Ltd801-810, NO.2 Building, Shanghai Technology Innovation Center, 100 Qinzhou Road, Shanghai 200235, ChinaTel: 0086 21 5169 1990 • Fax: 0086 21 5228 8095E-mail: [email protected] • Website: www.miccgroup.com

Certificate No: 1035a to BS EN 60702-1: 2002, BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50200: 2006, BS 8434-2: 2003+A2:2009 and BS 5839-1: 2002+A2:2008

Page 479: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 469

MICC Wiring CableNominal csa of

conductor (mm²)Core

constructionBS EN

60702-1(see note 7)

BS 6387

BS EN 50267-2-1

(outer covering)

BS EN 50200

BS 8434-2

BS 5839-1 Clause 26.2

LPCB Ref. No.

MICC Wiring Cable (Heavy

Duty)

1035a/01

1.5(1,3) one, 2, 3, 4 & 7

Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

2.5(1,3) one, 2, 3, 4 & 7

Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

4.0(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

6.0(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

10(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

16(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

25(1,3,4) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

35(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

50(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

70(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

95(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

120(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

150(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

185(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

240(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

300(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

400(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

MICC Wiring Cable (Light

Duty)1.5(1,2) 2, 3, 4 & 7 Complies(5) C,W,Z(5) <0.5%

HCl(6)Class

PH120(6)120min(6) Enhanced(6,8)

2.5(1,2) 2, 3, 4 & 7 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

4.0(1,2) 2 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

Notes:1) Solid conductor only.2) The MICC Wiring Cable (Light Duty) cables were tested at a voltage rating of 300/500V.3) The MICC Wiring Cable (Heavy Duty) cables were tested at a voltage rating of 450/750V.4) BS EN 50200: 2006, BS 8434-2: 2003+A2:2009 and BS 5839-1: 2002+A2:2008 approval applies to the 25mm2 cable at 1 & 2 cores

only.5) Approval applies to the Bare and Served cables.6) Approval applies to the Served cable only.7) In meeting the requirements of BS EN 60702-1: 2002, the MICC Wiring Cable Served cables listed met the requirements of smoke

density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997.

8) The MICC Wiring Cable Served cables listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Page 480: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

470 31 Dec 2012

Mineral Insulated Cable Co LtdTemperature House, 21 Sedling Road, Wear Industrial Estate, Washington, Tyne & Wear NE38 9BZ, United KingdomTel: +44 191 416 7777 • Fax: +44 191 419 2345E-mail: [email protected] • Website: www.temperature-house.com

Certificate No: 1039a to BS EN 60702-1: 2002, BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50200: 2006, BS 8434-2: 2003+A2:2009 and BS 5839-1: 2002+A2:2008

MICC Wiring CableNominal csa of

conductor (mm²)Core

constructionBS EN

60702-1(see note 7)

BS 6387

BS EN 50267-2-1

(outer covering)

BS EN 50200

BS 8434-2

BS 5839-1 Clause 26.2

LPCB Ref. No.

MICC Wiring Cable (Heavy

Duty)

1039a/01

1.5(1,3) one, 2, 3, 4 & 7

Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

2.5(1,3) one, 2, 3, 4 & 7

Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

4.0(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

6.0(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

10(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

16(1,3) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

25(1,3,4) one, 2, 3 & 4 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

35(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

50(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

70(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

95(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

120(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

150(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

185(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

240(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

300(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

400(1,3) one Complies(5) C,W,Z(5) <0.5% HCl(6)

- - -

MICC Wiring Cable (Light

Duty)1.5(1,2) 2, 3, 4 & 7 Complies(5) C,W,Z(5) <0.5%

HCl(6)Class

PH120(6)120min(6) Enhanced(6,8)

2.5(1,2) 2, 3, 4 & 7 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

4.0(1,2) 2 Complies(5) C,W,Z(5) <0.5% HCl(6)

Class PH120(6)

120min(6) Enhanced(6,8)

Note 1: Solid conductor only.Note 2: The MICC Wiring Cable (Light Duty) cables were tested at a voltage rating of 300/500V.Note 3: The MICC Wiring Cable (Heavy Duty) cables were tested at a voltage rating of 450/750V.Note 4: BS EN 50200: 2006, BS 8434-2: 2003+A2:2009 and BS 5839-1: 2002+A2:2008 approval applies to the 25mm2 cable at 1 & 2

cores only.Note 5: Approval applies to the Bare and Served cables.Note 6: Approval applies to the Served cable only.

Page 481: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 471

Note 7: In meeting the requirements of BS EN 60702-1: 2002, the MICC Wiring Cable Served cables listed met the requirements of smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997.

Note 8: The MICC Wiring Cable Served cables listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

NAJD ELECTRICALS & SAFETY EQUIPMENT TRADINGBaghdad Street, Al Qusais 2, PO Box 85961, Dubai, United Arab EmiratesTel: +971 4 267 5414 • Fax: +971 4 267 5443E-mail: [email protected] • Website: www.najdelec-safety.com

Certificate No: 568d-(cl-1) to IEC 60331-21: 1999, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

JST Fire Cable IEC 60331Nominal csa of

conductor (mm²)Core construction

drain wire & earth)

IEC 60331-21 BS EN 50267-2-1 BS EN 61034-2 LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies <0.5% HCl >60% 568d/011.5(1) 2, 3 & 4 Complies <0.5% HCl >60%2.5(1) 2, 3 & 4 Complies <0.5% HCl >60%

Uo/U 300/500V

Note: 1) Solid and Stranded conductors.

Certificate No: 568a-(cl-4) to BS 6387: 1994 and BS EN 50267-2-1: 1999

JST Fire CableNominal csa of

conductors (mm²)Core construction BS 6387 BS EN 50267-2-1

(outer covering)LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z <0.5% HCl 568a/011.5(1) 2, 3 & 4 C, W, Z <0.5% HCl2.5(1) 2, 3 & 4 C, W, Z <0.5% HCl4.0(2) 2, 3 & 4 C, W, Z <0.5% HCl

Uo/U 300/500V

Notes:1) Solid and Stranded conductors.2) Stranded conductor only.

Nexans Schweiz AGPasswangstrasse 20, CH-4226 Breitenbach, SwitzerlandTel: +41 61 785 4210 • Fax: +41 61 785 2240E-mail: [email protected] • Website: www.nexans.com

Certificate No: 1029a to BS 7629-1: 2008, BS 6387: 1994, BS EN 60332-3-24: 2009, BS EN 50200: 2006 PH120, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

ALSECURE NX200-BBNominal

csa of

conductor(mm²)

Core construction(excluding

drain wire and earth)

BS 7629-1 BS 6387

BS EN 60332-3-24

BS EN 50200

BS EN 50200

Annex E

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3, 4 & 7 Complies(3) C,W,Z Complies Class PH120

30min(4) Standard(5) 1029a/01

Page 482: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

472 31 Dec 2012

Nominal csa of

conductor(mm²)

Core construction(excluding

drain wire and earth)

BS 7629-1 BS 6387

BS EN 60332-3-24

BS EN 50200

BS EN 50200

Annex E

BS 5839-1Clause

26.2

LPCB Ref. No.

1.5(1) 2, 3, 4, 7, 12 & 19

Complies(3) C,W,Z Complies Class PH120

30min(4) Standard(5)

2.5(1) 2, 3, 4, 7 & 12 Complies(3) C,W,Z Complies Class PH120

30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) C,W,Z Complies Class PH120

30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the ALSECURE NX200-BB cables listed met the requirements of smoke density of

BS EN 61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tapes and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The ALSECURE NX200-BB cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Nexans Turkiye Endustri ve Ticaret A.S.Izmir Karayolu Uzeri 6.km, Denizli, TurkeyTel: 0090 212 266 0160 • Fax: 0090 212 266 0170E-mail: [email protected] • Website: www.nexans.com.tr

Certificate No: 946a to BS 7846: 2009 Category F2

NX400 ALSECURE PLUSNominal csa of

conductor (mm 2)Core Construction

(see note 1)BS 7846 LPCB Ref. No.

1.5 2, 3 & 4 F2(2) 946a/012.5 2, 3 & 4 F2(2)

4.0 2, 3 & 4 F2(2)

6.0 2, 3 & 4 F2(2)

10 2, 3 & 4 F2(2)

16 2, 3 & 4 F2(2)

25 2, 3 & 4 F2(2)

35 2, 3 & 4 F2(2)

50 2, 3 & 4 F2(2)

70 2, 3 & 4 F2(2)

95 2, 3 & 4 F2(2)

120 2, 3 & 4 F2(2)

150 2, 3 & 4 F2(2)

185 2, 3 & 4 F2(2)

240 2, 3 & 4 F2(2)

300 2, 3 & 4 F2(2)

400 2, 3 & 4 F2(2)

Uo/U 600/1000V

Notes:1) Stranded conductors only.2) In meeting the requirements of BS 7846: 2009 Category F2, the NX400 ALSECURE PLUS cables listed met the requirements for fire

resistance characteristics category CWZ specified in Clause 11 of BS 6387: 1994.

Certificate No: 946b to BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005 and IEC 60331-21: 1999

Page 483: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 473

NX100 ALSECURE PLUSNominal csa of conductor (mm

2)

Core construction(See note1)

BS 6387(See notes 2-

3)

BS EN 50267-2-1

BS EN 61034-2

IEC 60331-21

LPCB Ref. No.

1.5 One C,W,Z(4) <0.5% HCI >60% Complies 946b/012.5 One C,W,Z(4) <0.5% HCI >60% Complies4.0 One C,W,Z(4) <0.5% HCI >60% Complies6.0 One C,W,Z(4) <0.5% HCI >60% Complies10 One C,W,Z(4) <0.5% HCI >60% Complies16 One C,W,Z(5,6) <0.5% HCI >60% Complies25 One C,W,Z(5,6) <0.5% HCI >60% Complies35 One C,W,Z(5,6) <0.5% HCI >60% Complies50 One C,W,Z(5,6) <0.5% HCI >60% Complies70 One C,W,Z(5,6) <0.5% HCI >60% Complies95 One C,W,Z(5,6) <0.5% HCI >60% Complies120 One C(6) <0.5% HCI >60% Complies150 One C(6) <0.5% HCI >60% Complies185 One C(6) <0.5% HCI >60% Complies240 One C(6) <0.5% HCI >60% Complies300 One C(6) <0.5% HCI >60% Complies

Uo/U 450/750V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.4) To satisfy the requirement of BS 6387, testing for C, W & Z categories was conducted using a 20mm stainless steel conduit as the

other metallic element.5) To satisfy the requirement of BS 6387, testing for W & Z categories was conducted using a 20mm stainless steel conduit as the other

metallic element.6) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.

Norden Communication UK Ltd2nd Floor, 145-157 St John Street, London EC1V 4PY, United KingdomTel: +44 (0) 207 788 7663 • Fax: +44 (0) 203 292 1987E-mail: [email protected] • Website: www.nordencommunication.com

Certificate No: 711c-(cl-1) to BS 6387: 1994 and BS EN 50200: 2006 Class PH30

FireNor PH30Nominal csa of

conductors (mm²)Core constructiondrain wire & earth)

BS 6387 BS EN 50200 LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z Class PH30 711c/011.5(1) 2, 3 & 4 C, W, Z Class PH302.5(1) 2, 3 & 4 C, W, Z Class PH30

Uo/U 300/500V

Note:1. Solid conductor only.

OLYMPIC CABLE COMPANY SDN. BHD.Lot PT 2126-2131, Jalan PK1, Taman Perindustrian Krubong, 75250 Melaka, MalaysiaTel: +606 337 3088 • Fax: +606 335 1911E-mail: [email protected] • Website: www.olympic-cable.com.my

Certificate No: 1122a to BS 6387: 1994, BS EN 61034-2: 2005, BS EN 50267-2-1: 1999, IEC 60331-21: 1999, IEC 60332-3-22: 2009 and IEC 60332-3-24: 2009

Page 484: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

474 31 Dec 2012

OCC-F6C01Nominal csa

ofconductor

(mm 2)

Coreconstruction

BS 6387(See notes

2-4)

BS EN 50267-2-1

BS EN 61034-2

IEC 60332-3-22

IEC 60332-3-24

IEC 60331-21(See note

9)

LPCB Ref. No.

1.5(1) One C,W,Z(5) <0.5% HCl >60% Complies - Complies 1122a/012.5(1) One C,W,Z(6,7) <0.5% HCl >60% Complies - Complies4.0(1) One C,W,Z(6,7) <0.5% HCl >60% Complies - Complies6.0(1) One C,W,Z(6,7) <0.5% HCl >60% Complies - Complies10(1) One C,W,Z(6,7) <0.5% HCl >60% Complies Complies16(1) One C,W,Z(6,7) <0.5% HCl >60% Complies - Complies25(1) One C,W,Z(6,7) <0.5% HCl >60% Complies - Complies35(1) One C,W,Z(6,7) <0.5% HCl >60% Complies Complies Complies50(1) One C,W,Z(6,7) <0.5% HCl >60% - Complies Complies70(1) One C(7) <0.5% HCl >60% - Complies Complies95(1) One C(7) <0.5% HCl >60% - Complies Complies120(1) One C(7) <0.5% HCl >60% - Complies Complies150(1) One C(7) <0.5% HCl >60% - Complies Complies185(1) One C(7) <0.5% HCl >60% - Complies Complies240(1) One C(7) <0.5% HCl >60% - Complies Complies300(1) One C(7) <0.5% HCl >60% - Complies Complies400(1) One Complies(8) <0.5% HCl >60% - Complies Complies500(1) One Complies(8) <0.5% HCl >60% - Complies Complies630(1) One Complies(8) <0.5% HCl >60% - Complies Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.4) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.5) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.6) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.7) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.8) Only Clause 10 of BS 6387 was conducted.9) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 750oC and at a voltage rating of 600V.

Oman Cables Industry (SAOG)Road No.2, Factory No. 206, Rusayl Industrial Estate, Rusayl, Muscat, Sultanate of OmanTel: +968 24446464 • Fax: +968 24446096E-mail: [email protected] • Website: www.omancables.com

Certificate No: 995a to BS 7846: 2009 Category F2

OCIFLAM-FSANominal csa of conductor (mm 2) Core construction (see note 1) BS 7846 LPCB Ref. No.

16 2, 3 & 4 F2(2) 995a/0125 2, 3 & 4 F2(2)

35 2, 3 & 4 F2(2)

50 2, 3 & 4 F2(2)

70 2, 3 & 4 F2(2)

95 2, 3 & 4 F2(2)

120 2, 3 & 4 F2(2)

150 2, 3 & 4 F2(2)

185 2, 3 & 4 F2(2)

240 2, 3 & 4 F2(2)

300 2, 3 & 4 F2(2)

400 2, 3 & 4 F2(2)

Uo/U 600/1000V

Notes:1) Stranded conductors only.

Page 485: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 475

2) In meeting the requirements of BS 7846: 2009 Category F2, the OCIFLAM-FSA cables listed met the requirements of smoke density of BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, tapes, filler, bedding and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

Prysmian Cables & Systems LimitedEnergy Cables, Chickenhall Lane, Bishopstoke, Eastleigh, Hants SO50 6YU, United KingdomTel: +44 (0)8457 678345 • Fax: +44 (0)2380 295465E-mail: [email protected] • Website: www.prysmian.co.uk

Certificate No: 077a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

FP200 Gold LSOHNominal csa of

conductor (mm2)Core

Construction (excluding drain wire & earth)

BS 7629-1(Incorporating

Amendments Nos. 1 and 2)

LPCB Ref. No.

1.0 7 Complies(1) 077a/021.5 7, 12 & 19 Complies(1)

2.5 7 & 12 Complies(1)

Uo/U 300/500V

Note:1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Gold LSOH cables listed met

the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999.

Certificate No: 077a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

FP200 FlexNominal csa of

conductor (mm2)Core

Construction (excluding drain wire & earth)

BS 7629-1(Incorporating

Amendments Nos. 1 and 2)

LPCB Ref. No.

1.0 2, 3 & 4 Complies(1) 077a/031.5 2, 3 & 4 Complies(1)

2.5 2, 3 & 4 Complies(1)

Uo/U 300/500V

Note:1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Flex cables listed met the

requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999.

Certificate No: 077b to BS 6387: 1994 and BS EN 50267-2-1: 1999

FP300 fire resistant cable LSOH outer coveringNominal csa of

conductor (mm2)Core

ConstructionBS 6387

(see note 1)BS EN 50267-2-1(outer covering)

LPCB Ref. No.

1.0 2, 3 & 4 C, W, Z <0.5% HCl 077b/011.5 2, 3 & 4 C, W, Z <0.5% HCl2.5 2, 3 & 4 C, W, Z <0.5% HCl4.0 2, 3 & 4 C, W, Z <0.5% HCl6.0 2, 3 & 4 C, W, Z <0.5% HCl10 2, 3 & 4 C, W, Z <0.5% HCl16 2, 3 & 4 C, W, Z <0.5% HCl

Uo/U 450/750V

Note:1) The FP300 LSOH cable also met Category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.

Page 486: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

476 31 Dec 2012

Certificate No: 077b to BS 6387: 1994 and BS EN 50267-2-1: 1999

FP400 fire resistant cable LSOH outer coveringNominal csa of

conductor (mm2)Core

ConstructionBS 6387

(see note 1)BS EN 50267-2-1(outer covering)

LPCB Ref. No.

1.0 2, 3, & 4 C, W, Z <0.5% HCl 077b/021.5 2, 3, & 4 C, W, Z <0.5% HCl2.5 2, 3, & 4 C, W, Z <0.5% HCl4.0 2, 3, & 4 C, W, Z <0.5% HCl6.0 2, 3, & 4 C, W, Z <0.5% HCl10 2, 3, & 4 C, W, Z <0.5% HCl16 2, 3, & 4 C, W, Z <0.5% HCl25 2, 3, & 4 C, W, Z <0.5% HCl35 2, 3, & 4 C, W, Z <0.5% HCl50 2, 3, & 4 C, W, Z <0.5% HCl70 2, 3, & 4 C, W, Z <0.5% HCl95 2, 3, & 4 C, W, Z <0.5% HCl

120 2, 3, & 4 C, W, Z <0.5% HCl150 2, 3, & 4 C, W, Z <0.5% HCl185 2, 3, & 4 C, W, Z <0.5% HCl240 2, 3, & 4 C, W, Z <0.5% HCl300 2, 3, & 4 C, W, Z <0.5% HCl400 2, 3, & 4 C, W, Z <0.5% HCl

Uo/U 450/750V

Notes:1) The FP400 cable also met category C, W, Z when tested for voltage rating 600/1000 V which is not recognised by BS 6387.2) The FP400 cable approved with insulation type XLPE (GP8).3) The FP400 cable approved with insulation type EPR (GP6).

Certificate No: 077b to BS 6387: 1994 and BS EN 50267-2-1: 1999

FP200 Gold LSOHNominal csa of

conductor (mm2)Core

Construction (excluding drain wire & earth)

BS 6387 BS EN 50267-2-1(binder tape & outer covering)

LPCB Ref. No.

2.5 19 C & W <0.5% HCl 077b/03

Uo/U 300/500V

Certificate No: 077c to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

FP100 Fire resistant single core cable for installation in conduitNominal csa of

conductor (mm2)Core

ConstructionBS 6387

(see notes 1 - 4)BS EN 50267-2-1(outer covering)

IEC 60331-21(see Note 5)

LPCB Ref. No.

1.0 One C, W, Z <0.5% HCl - 077c/011.5 One C, W, Z <0.5% HCl -2.5 One C, W, Z <0.5% HCl -4.0 One C, W, Z <0.5% HCl -6.0 One C, W, Z <0.5% HCl -10 One C, W, Z <0.5% HCl -16 One C, W, Z - Complies25 One C, W, Z - Complies35 One C, W, Z - Complies50 One C, W, Z - Complies70 One C, W, Z - Complies95 One C, W, Z - Complies

120 One C - Complies150 One C - Complies185 One - - Complies240 One - - Complies300 One - - Complies400 One - - Complies500 One - - Complies630 One - - Complies

Page 487: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 477

Uo/U 450/750V

Notes:1) Testing was conducted using 20mm steel conduit.2) To satisfy the requirement of BS 6387 the conduit was considered as the other metallic element. 3) Clauses 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.4) Only a single cable is fitted in conduit, hence only phase to earth voltage was applied.5) Testing to IEC 60331 was conducted at voltage rating of 600/1000V and at 950ºC.

Certificate No: 077d to BS 6387: 1994, BS EN 50267-2-1: 1999 and BS EN 50268-2:2000

FP150 LS0HNominal csa of

conductor (mm2)Core

Construction (excluding drain wire & earth)

BS 6387 BS EN 50267-2-1(outer covering)

BS EN 50268-2 LPCB Ref. No.

1.0 2, 3 & 4 C, W, Z <0.5% HCl >60% 077d/011.5 2, 3 & 4 C, W, Z <0.5% HCl >60%2.5 2, 3 & 4 C, W, Z <0.5% HCl >60%

Uo/U 300/500V

Certificate No: 077e to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21:1999

FP 300 single core cableNominal csa of

conductor (mm2)Core

ConstructionBS 6387

(see notes 1,2, & 5)BS EN 50267-2-1(outer covering)

IEC 60331-21(see Note 7)

LPCB Ref. No.

1.0 One C, W, Z(3) <0.5% HCl Complies 077e/011.5 One C, W, Z(3) <0.5% HCl Complies2.5 One C, W, Z(3) <0.5% HCl Complies4.0 One C, W, Z(3) <0.5% HCl Complies6.0 One C, W, Z(3) <0.5% HCl Complies10 One C, W, Z(3) <0.5% HCl Complies16 One C, W, Z(3) <0.5% HCl Complies25 One C, W, Z(3) <0.5% HCl Complies35 One C, W, Z(3) <0.5% HCl Complies50 One C(4) <0.5% HCl Complies70 One C(4) <0.5% HCl Complies95 One C(4) <0.5% HCl Complies

120 One C(4) <0.5% HCl Complies150 One C(4) <0.5% HCl Complies185 One C(4) <0.5% HCl Complies240 One C(4) <0.5% HCl Complies300 One Complies(6) <0.5% HCl Complies400 One Complies(6) <0.5% HCl Complies500 One Complies(6) <0.5% HCl Complies630 One Complies(6) <0.5% HCl Complies

Uo/U 450/750V

Notes:1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) of the BS 6387 standard cannot be conducted due to the cable having only one core.2) The single core cable also met category C, W, Z when tested for voltage rating 600/1000 V which is not recognised by BS 6387.3) To satisfy the requirement of BS 6387, testing for C, W and Z categories was conducted using a 20mm steel conduit as the other

metallic element.4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic

element.5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.6) Only clause 10 of BS 6387 was conducted. 7) Testing to IEC 60331 was conducted at voltage rating of 600/1000V and at 950oC.

Certificate No: 077e to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

FP 300MI single core cableNominal csa of

conductor (mm2)Core

ConstructionBS 6387

(see notes 1, 2 & 5)BS EN 50267-2-1(outer covering)

IEC 60331-21(see note 7)

LPCB Ref. No.

1.0 One C, W, Z(3) <0.5% HCl Complies 077e/021.5 One C, W, Z(3) <0.5% HCl Complies2.5 One C, W, Z(3) <0.5% HCl Complies

Page 488: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

478 31 Dec 2012

Nominal csa of conductor (mm2)

CoreConstruction

BS 6387(see notes 1, 2 & 5)

BS EN 50267-2-1(outer covering)

IEC 60331-21(see note 7)

LPCB Ref. No.

4.0 One C, W, Z(3) <0.5% HCl Complies6.0 One C, W, Z(3) <0.5% HCl Complies10 One C, W, Z(3) <0.5% HCl Complies16 One C, W, Z(3) <0.5% HCl Complies25 One C, W, Z(3) <0.5% HCl Complies35 One C, W, Z(3) <0.5% HCl Complies50 One C(4) <0.5% HCl Complies70 One C(4) <0.5% HCl Complies95 One C(4) <0.5% HCl Complies

120 One C(4) <0.5% HCl Complies150 One C(4) <0.5% HCl Complies185 One C(4) <0.5% HCl Complies240 One C(4) <0.5% HCl Complies300 One Complies(6) <0.5% HCl Complies400 One Complies(6) <0.5% HCl Complies500 One Complies(6) <0.5% HCl Complies630 One Complies(6) <0.5% HCl Complies

Uo/U 450/750V

Notes:1) Clause 8 (Bending) and 9.1 & 9.2 (Impact) of the BS 6387 standard cannot be conducted due to the cable having only one core.2) The single core cable also met category C, W, Z when tested for voltage rating 600/1000 V which is not recognised by BS 6387.3) To satisfy the requirement of BS 6387, testing for C,W, and Z categories was conducted using a 20mm steel conduit as the other

metallic element.4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm steel conduit as the other metallic

element.5) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.6) Only clause 10 of BS 6387 was conducted.7) Testing to IEC 331 was conducted at voltage rating of 600/1000V and at 950°C which is not recognised by the standard.

Certificate No: 077f to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30 & PH60 and BS 5839-1: 2002 Clause 26.2d

FP200 Gold LSOHNominal csa of

conductor (mm2)

CoreConstruction

(excluding drain wire & earth)

BS 7629-1(Incorporating AmendmentNos. 1 & 2)

BS EN 50200 BS 5839-1Clause

26.2

LPCB Ref. No.

1.0 2, 3 & 4 Complies(1) Class PH30 Standard(2) 077f/011.5 2, 3 & 4 Complies(1) Class PH30 &

PH60Standard(2)

2.5 2, 3 & 4 Complies(1) Class PH30 & PH60

Standard(2)

4.0 2, 3 & 4 Complies(1) Class PH30 & PH60

Standard(2)

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the FP200 Gold LSOH cables listed met

the requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

2) The FP200 Gold LSOH cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the requirements of the additional fire, mechanical shock and water tests described in Clause 26.2 d) of BS 5839-1: 2002 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Certificate No: 077g to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 120 min and BS 5839-1: 2002+A2:2008 Clause 26.2e

FP PlusNominal csa of

conductor (mm2)Core

Construction(exluding drain wire & earth)

BS 7629-1 BS EN 50200 BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies Class PH120 120min(3) Enhanced 077g/011.5 2, 3 & 4 Complies Class PH120 120min(3) Enhanced

Page 489: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 479

Nominal csa of conductor (mm2)

CoreConstruction

(exluding drain wire & earth)

BS 7629-1 BS EN 50200 BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

2.5 2, 3 & 4 Complies(2) Class PH120 120min(3) Enhanced

Uo/U 300/500V

Notes:

1) Solid conductor only.2) In meeting the requirements of BS 7629-1: 2008, the FP Plus cables listed met the requirements of smoke density of BS EN 61034-2:

2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on insulation, binder tapeand outer covering when tested in accordance with BS EN 50267-2-1: 1999.

3) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

4) The FP Plus cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence meet the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 077h to BS 7629-1: 1997 (Incorporating Amendment No.1), BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: Clause 26.2e

FP Plus FlexNominal csa of

conductor (mm2)Core

Construction(excluding drain

wire & earth)

BS 7629-1(Incorporating

Amendment No.1)

BS EN 50200 BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0 2,3 & 4 Complies (1) Class PH120 120min(2) Enhanced(3) 077h/011.5 2,3 & 4 Complies(1) Class PH120 120min(2) Enhanced(3)

2.5 2,3 & 4 Complies(1) Class PH120 120min(2) Enhanced(3)

4.0 2,3 & 4 Complies(1) Class PH120 120min(2) Enhanced(3)

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendment No.1), the FP Plus Flex cables listed met the

requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS EN 50267-2-1: 1999.

2) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002.

3) The FP Plus Flex cables listed conform to BS 7629-1: 1997 (Incorporating Amendment No.1), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Certificate No: 077j to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).

FP200 Gold LSOHNominal csa of

conductor (mm2)Core

Construction(excluding drain wire & earth)

BS 7629-1(see Note 2)

LPCB Ref. No.

1.0 7 Complies (1) 077j/011.5 7, 12 & 19 Complies (1)

2.5 7 & 12 Complies (1)

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 1997, the FP200 Gold LSOH cables listed met the requirements of smoke density of BS

7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS 6425-1: 1990.

2) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 077a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

Page 490: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

480 31 Dec 2012

Certificate No: 077j to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).

FP200 FlexNominal csa of

conductor (mm2)Core

Construction(excluding drain wire & earth)

BS 7629-1(see Note 2)

LPCB Ref. No.

1.0 2, 3 & 4 Complies (1) 077j/021.5 2, 3 & 4 Complies (1)

2.5 2, 3 & 4 Complies (1)

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 1997, the FP200 Flex cables listed met the requirements of smoke density of BS 7622-2:

1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS 6425-1: 1990.

2) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 077a covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

Certificate No: 077k to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 Class PH30 & PH60 and BS 5839-1: 2002 Clause 26.2d

FP200 Gold LSOHNominal csa of

conductor (mm2)Core

Construction(excluding drain

wire & earth)

BS 7629-1(see Note 3)

BS EN 50200 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0 2, 3 & 4 Complies (1) Class PH30 Standard (2) 077k/011.5 2, 3 & 4 Complies (1) Class PH30 & PH60 Standard (2)

2.5 2, 3 & 4 Complies (1) Class PH30 & PH60 Standard (2)

4.0 2, 3 & 4 Complies (1) Class PH30 & PH60 Standard (2)

Uo/U 300/500V

Notes:1) In meeting the requirements of BS 7629-1: 1997, the FP200 Gold LSOH cables listed met the requirements of smoke density of BS

7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the (insulation, binder tape & outer covering) when tested in accordance with BS 6425-1: 1990.

2) The FP200 Gold LSOH cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the requirements of the additional fire, mechanical shock and water tests described in Clause 26.2 d) of BS 5839-1: 2002 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

3) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 077f covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

Certificate No: 077g to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 120min and BS 5839-1: 2002+A2:2008 Clause 26.2e

FP PlusNominal csa of

conductor (mm 2)Core Construction

(excluding drain wire & earth)BS 7629-1 BS EN 50200 BS 8434-2 BS 5839-1

Clause 26.2LPCB Ref. No.

1.5(1) 2 Complies(2) Class PH120 120min(3) Enhanced(4) 077g/022.5(1) 2 Complies(2) Class PH120 120min(3) Enhanced(4)

Uo/U 300/500V

Page 491: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 481

Notes:1) Solid conductor only.2) In meeting the requirements of bs 7629-1: 2008, the FP Plus cables listed met the requirements of smoke density of BS EN 61034-2:

2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

3) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

4) The FP Plus cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2 :2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 077m to BS 7346-6: 2005, BS 8491: 2008, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

FP600Nominal csa

ofconductor

(mm 2)

Core construction

BS 7346-6 (fire survival time)

BS 8491 (fire survival time see note 2)

BS EN 50267-2-1

BS EN 61034-2

LPCB Ref. No.

4.0(1) 2, 3 & 4 120min 120min <0.5% HCl >60% 077m/016.0(1) 2, 3 & 4 120min 120min <0.5% HCl >60%10(1) 2, 3 & 4 120min 120min <0.5% HCl >60%16(1) 2, 3 & 4 120min 120min <0.5% HCl >60%25(1) 2, 3 & 4 120min 120min <0.5% HCl >60%35(1) 2, 3 & 4 120min 120min <0.5% HCl >60%50(1) 2, 3 & 4 120min 120min <0.5% HCl >60%70(1) 2, 3 & 4 120min 120min <0.5% HCl >60%

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) In achieving 120min fire survival time in accordance with BS 7346-6: 2005, the FP600 cables listed also achieved a 120min fire

survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346: 2005 Annex B.

Certificate No: 077n to BS 7346-6: 2005, BS 8491: 2008, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

FP600SNominal csa

ofconductor

(mm 2)

Core construction (see note 2)

BS 7346-6 (fire survival time)

BS 8491 (fire survival time see note 3)

BS EN 50267-2-1

BS EN 61034-2

LPCB Ref. No.

2.5(1) 7 120min 120min <0.5%HCl >60% 077n/014.0(1) 2, 3 & 4 120min 120min <0.5%HCl >60%6.0(1) 2, 3 & 4 120min 120min <0.5%HCI >60%10(1) 2, 3 & 4 120min 120min <0.5%HCI >60%16(1) 2, 3 & 4 120min 120min <0.5%HCI >60%25(1) 2, 3 & 4 120min 120min <0.5%HCI >60%35(1) 2, 3 & 4 120min 120min <0.5%HCI >60%50(1) 2, 3 & 4 120min 120min <0.5%HCI >60%70(1) 2 & 3 120min 120min <0.5%HCI >60%

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) All 2 core cables have the blue core designated as a Neutral conductor; only phase to earth voltage was applied.3) In achieving a 120min fire survival time in accordance with BS 7346-6: 2005, the FP600S cables listed also achieved a 120min fire

survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346-6: 2005, Annex B.

Certificate No: 077g to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 120min and BS 5839-1: 2002+A2 2008 Clause 26.2e

FP PlusNominal csa ofconductor (mm2

Core construction(excluding drain wire & earth)

BS 7629-1 BS EN 50200 BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

1.5 2, 3 & 4 Complies Class PH120 120min Enhanced 077g/03

Page 492: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

482 31 Dec 2012

Nominal csa ofconductor (mm2

Core construction(excluding drain wire & earth)

BS 7629-1 BS EN 50200 BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

2.5 2, 3 & 4 Complies Class PH120 120mm Enhanced

Uo/U 300/500V

Notes:1 Solid conductor only.2. In meeting the requirements of BS 7629-1: 2008, the FP Plus cables listed met the requirements of smoke density of BS EN 61034-2:

2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

3. The duration of 120 min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

4. The FP Plus cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Prysmian Cables & Systems LimitedEnergy Cables Unit, Wrexham Industrial Estate, Wrexham LL13 9PH, United KingdomTel: +44 (0)1978 662345 • Fax: +44 (0)1978 662292E-mail: [email protected] • Website: www.prysmian.co.uk

Certificate No: 517a to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

FP300 Single Core LSZH CableNominal csa of

conductor (mm2)Core

ConstructionBS 6387

(see notes 1 to 4)BS EN 50267-2-1(outer covering)

IEC 60331-21(see note 6)

LPCB Ref. No.

50 One C <0.5%HCI Complies 517a/0170 One C <0.5%HCI Complies95 One C <0.5%HCI Complies120 One C <0.5%HCI Complies185 One C <0.5%HCI Complies240 One C <0.5%HCI Complies300 One Complies(5) <0.5%HCI Complies400 One Complies(5) <0.5%HCI Complies630 One Complies(5) <0.5%HCI Complies800 One Complies(5) <0.5%HCI Complies

1000 One Complies(5) <0.5%HCI Complies

Uo/U 450/750V

Notes:1) These cables also met category C when tested for voltage rating 600/1000V which is not recognised by BS 6387.2) Clause 8 (bending) and 9.1 & 9.2 (impact) can not be conducted due to the cable having only one core.3) To satisfy the requirement of BS 6387, testing for category C was conducted using 38mm steel conduit as the other metallic element.4) Where single cable is fitted in conduit, only phase to earth voltage was applied. 5) Only clause 10 of BS 6387 was conducted.6) These cables met the requirements of IEC 60331 when tested at a temperature of 950°C (which is not recognised by IEC 60331) and

at a voltage rating of 600V.

Certificate No: 517b to BS 6387:1994

FP400 Fire resistant cableNominal csa of

conductor (mm2)Core

ConstructionBS 6387 (see note 1) LPCB Ref. No.

50 2, 3 & 4 C, W, Z 517b/0170 2, 3 & 4 C, W, Z95 2, 3 & 4 C, W, Z120 2, 3 & 4 C, W, Z185 2, 3 & 4 C, W, Z240 2, 3 & 4 C, W, Z300 2, 3 & 4 C, W, Z400 2, 3 & 4 C, W, Z

Uo/U 450/750V

Page 493: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 483

Note:1) The FP400 cable also met categories C, W, and Z when tested for voltage rating of 600/1000V which is not recognised by BS 6387.

Certificate No: 517c to BS 7346-6: 2005, BS 8491: 2008, BS EN 50267-2-1: 1999 and BS EN 61034-2: 2005

FP600SNominal csa of

conductor (mm 2)Core

constructionBS 7346-6

(fire survival time)

BS 8491(fire survival

timesee note 2)

BS EN 50267-2-1

BS EN 61034-2

LPCB Ref. No.

70(1) 2, 3 & 4 120min 120min <0.5% HCl >60% 517c/0195(1) 2, 3 & 4 120min 120min <0.5% HCl >60%120(1) 2, 3 & 4 120min 120min <0.5% HCl >60%150(1) 2, 3 & 4 120min 120min <0.5% HCl >60%185(1) 2, 3 & 4 120min 120min <0.5% HCl >60%240(1) 2, 3 & 4 120min 120min <0.5% HCl >60%300(1) 2, 3 & 4 120min 120min <0.5% HCl >60%400(1) 2, 3 & 4 120min 120min <0.5% HCl >60%

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) In achieving a 120min fire survival time in accordance with BS 7346-6: 2005, the FP600S cables listed also achieved a 120min fire

survival time in accordance with BS 8491: 2008. The test method given in BS 8491: 2008 is technically identical to the test method given in BS 7346-6: 2005, Annex B.

RAMCRO S.p.AVia Marzorati, 15 - 20014 Nerviano, Milan, ItalyTel: +39 0331 406560 • Fax: +39 0331 406559E-mail: [email protected]

Certificate No: 568a to BS 6387: 1994 and BS EN 50267-2-1: 1999

Ramfirecro-F3Nominal csa of

conductor (mm2)Core

ConstructionBS 6387 BS EN 50267-2-1

(outer covering)LPCB Ref. No.

1.0(1) 2, 3 & 4 C, W, Z <0.5%HCI 568a/011.5(1) 2, 3 & 4 C, W, Z <0.5%HCI2.5(1) 2, 3 & 4 C, W, Z <0.5%HCI4.0(2) 2, 3 & 4 C, W, Z <0.5%HCI

Uo/U 300/500V

Notes:1) Solid and stranded conductors.2) Stranded conductor only.

Certificate No: 568b to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min & BS 5839-1:2002 Clause 26.2d

Ramfirecro-F3 StandardNominal csa of

conductor (mm²)Core

Construction(excluding drain

wire & earth)

BS 7629-1(see note 6)

BS EN 50200 BS 8434-1 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0 (1) 2 ,3 & 4 Complies (3) Class PH30 30min (4) Standard (5) 568b/011.5 (1) 2, 3 & 4 Complies (3) Class PH30 30min (4) Standard (5)

2.5 (1) 2, 3 & 4 Complies (3) Class PH30 30min (4) Standard (5)

4.0 (2) 2, 3 & 4 Complies (3) Class PH30 30min (4) Standard (5)

Uo/U 300/500V

Page 494: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

484 31 Dec 2012

Notes:1) Solid and Stranded conductors.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997, the Ramfirecro-F3 Standard cables listed met the requirements of smoke density of

BS 7622-2: 1993 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS 6425-1: 1990.

4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2 d) of BS 5839-1: 2002.

5) The Ramfirecro-F3 Standard cables listed conform to BS 7629-1: 1997, met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

6) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 568c covers cables certified in accordance with BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2)

Certificate No: 568c to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

Ramfirecro-F3 StandardNominal csa of

conductor (mm²)Core

Construction(excluding drain

wire & earth)

BS 7629-1(Incorporating Amendments Nos. 1 and 2)

BS EN 50200 BS 8434-1 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0 (1) 2, 3 & 4 Complies(3) Class PH30 30min (4) Standard (5) 568c/011.5 (1) 2, 3 & 4 Complies(3) Class PH30 30min (4) Standard (5)

2.5 (1) 2, 3 & 4 Complies(3) Class PH30 30min (4) Standard (5)

4.0 (2) 2, 3 & 4 Complies(3) Class PH30 30min (4) Standard (5)

Uo/U 300/500V

Notes:1) Solid and Stranded conductors.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), the Ramfirecro-F3 Standard cables listed

met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the insulation, binder tape &outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002.

5) The Ramfirecro-F3 Standard cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Certificate No: 568d to IEC 60331-21: 1999, BS EN 50267-2-1: 1999, BS EN 61034-2: 2005

Ramfirecro-F3 IEC 60331Nominal csa of

conductor (mm²)Core construction(excluding drain

wire & earth)

IEC 60331-21 BS EN 50267-2-1 BS EN 61034-2 LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies <0.5% HCl >60% 568d/011.5(1) 2, 3 & 4 Complies <0.5% HCl >60%2.5(1) 2, 3 & 4 Complies <0.5% HCl >60%

Uo/U 300/500V

Notes: 1) Solid and Stranded conductors.

Page 495: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 485

Shakun Polymers Limited(Cable Division), Plot No. 4, Silver Industrial Estate, Bhimpore, Patalia Road, Daman 396 210, IndiaTel: +91 260 222 1538 • Fax: +91 260 222 1199E-mail: [email protected] • Website: www.shakuncables.com

Certificate No: 978a to BS 7629-1: 2008, BS 6387: 1994, BS EN 50200: 2006 Class PH30, BS EN 50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

Fr TekNominal csa ofconductor (mm2

Core construction(excluding drainwire and earth)

BS 7629-1 BS6387 BS EN 50200 BS EN 50500 Annex E

BS 5839-1Clause 26:2

LPCB Ref. No.

1.5(1) 2 Complies(2) C,W,Z Class PH30 30min(3) Standard(4) 978a/01

Uo/U 300/500V

Notes:1) Solid conductor only.2) In meeting the requirements of BS 7629-1: 2008, the FrTek cable listed met the requirements of smoke density of BS EN 61034-2:

2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

3) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

4) The FrTek cable listed conform to BS 7629-1: 2008, met Class PH30 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

SHIELD FIRE, SAFETY AND SECURITY LTD29th Floor Regus Suite, One Canada Square, Canary Wharf, London E14 5DY, United KingdomTel: +44 207 712 1610 • Fax: +44 207 712 1578E-mail: [email protected] • Website: www.shieldglobal.com

Certificate No: 682a-(cl-5) to BS 7629-1: 2008, BS 5839-1: 2002+A2:2008 Clause 26.2d, BS EN 50200: 2006 Annex E and BS EN 50200: 2006 Class PH120

Shield-UKNominal csa of

conductor (mm²)Core construction

(excluding drain wire & earth)

BS 7629-1 BS EN 50200

BS EN 50200 Annex E

BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5) 682a/01

1.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Shield-UK cables listed met the requirements of smoke density of BS EN 61034-

2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outercovering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The Shield-UK cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Page 496: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

486 31 Dec 2012

Tai Sin Electric Limited24 Gul Crescent, Jurong Town, Singapore 629531, SingaporeTel: +65 6861 3401 • Fax: +65 6861 4084E-mail: [email protected] • Website: www.taisin.com.sg

Certificate No: 982a to BS 7629-1: 2008, BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min

FRA-XOL (E)Nominal csa of

conductor (mm 2)Core construction(excluding drain wire and earth)

BS 7629-1 BS 6387 BS EN 50200 BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5) 982a/011.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5)

2.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5)

4.0(2) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the FRA-XOL (E) cables listed met the requirements of smoke density of BS EN

61034-2: 2005 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

5) The FRA-XOL (E) cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Certificate No: 982b to BS 7629-1: 1997 This certificate is to a withdrawn version of the BS 7629-1: 1997. Cables conforming to this version of the standard may not be suitable for use within the jurisdication of the European Union (EU), BS 6387: 1994, BS 5839-1: 2002+A2:2008 Clause 26.2e, BS EN 50200: 2006 Class PH120 and BS 8434-2: 2003+A2:2009 120min

FRA-XOL (E)Nominal csa of

conductor (mm 2)Core construction(excluding drainwire and earth)

BS 7629-1(see note 6)

BS6387 BS EN 50200 BS 8434-2 BS 5839-1Clause 26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5) 982b/011.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5)

2.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5)

4.0(2) 2, 3 & 4 Complies(3) C,W,Z Class PH120 120min(4) Enhanced(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997, the FRA-XOL (E) cables listed met the requirements of smoke density of BS EN

50268-2: 2000 and achieved less than 0.5%HCI on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase.

5) The FRA-XOL (E) cables listed conform to BS 7629-1: 1997, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 120min duration when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

6) BS 7629-1: 1997 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 982a covers cables certified in accordance with BS 7629-1: 2008

Page 497: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 487

TELE-FONIKA Kable Sp. z o.o., S.K.A.ul.Wielicka 114, 30-663 Krakow, PolandTel: +48 12 652 50 00 • Fax: +48 12 652 51 56E-mail: [email protected] • Website: www.tfkable.pl

Certificate No: 814b to BS 7629-1: 1997 (Incorporating Amendments. Nos. 1 and 2), BS 6387: 1994, BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min and BS 5839-1: 2002 Clause 26.2e

FLAME-X 950 EnhancedNominal csa of

conductor (mm²)Core

Constructiondrain

wire & earth)

BS 7629-1(Incorporating

Amendments Nos. 1 and 2)

BS6387 BS EN 50200

BS 8434-2

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120

120min(4) Enhanced(5) 814b/01

1.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120

120min(4) Enhanced(5)

2.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH120

120min(4) Enhanced(5)

4.0(2) 2, 3 & 4 Complies(3) C,W,Z Class PH120

120min(4) Enhanced(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FLAME-X 950 Enhanced cables

listed met the requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2e) of BS 5839-1: 2002.

5) The FLAME-X 950 Enhanced cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH120 when tested in accordance with BS EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Certificate No: 814a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), BS 6387: 1994, BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min and BS 5839-1: 2002 Clause 26.2d

FLAME-X 950Nominal csa of

conductor (mm²)Core

Construction(excluding

drainwire & earth)

BS 7629-1(Incorporating

Amendments Nos. 1 & 2)

BS 6387

BS EN 50200

BS 8434-1

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) C,W,Z Class PH30

30min(4) Standard(5) 814a/01

1.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH30

30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) C,W,Z Class PH30

30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) C,W,Z Class PH30

30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only2) Stranded conductor only3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FLAME-X 950 cables listed met the

requirements of smoke density of BS EN 50268-2: 2000 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002.

Page 498: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

488 31 Dec 2012

5) The FLAME-X 950 cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met a duration of 30min when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Certificate No: 814d to BS 7846: 2000 (Incorporating Amendments Nos. 1 and 2)

FLAME-X 950 PowerNominal csa of conductor (mm²) Core Construction BS 7846: 2000

(Incorporating Amendments Nos. 1 and 2)LPCB Ref. No.

1.5 (1) 2, 3 & 4 F2(2) 814d/012.5 (1) 2, 3 & 4 F2(2)

4.0 (1) 2, 3 & 4 F2(2)

6.0 (1) 2, 3 & 4 F2(2)

10(1) 2, 3 & 4 F2(2)

16(1) 2, 3 & 4 F2(2)

25(1) 2, 3 & 4 F2(2)

35 (1) 2, 3 & 4 F2(2)

50 (1) 2, 3 & 4 F2(2)

70(1) 2, 3 & 4 F2(2)

95 (1) 2, 3 & 4 F2(2)

120 (1) 2, 3 & 4 F2(2)

150(1) 2, 3 & 4 F2(2)

185(1) 2, 3 & 4 F2(2)

240(1) 2, 3 & 4 F2(2)

300(1) 2, 3 & 4 F2(2)

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) In meeting the requirements of BS 7846: 2000 (Incorporating Amendments Nos. 1 and 2) Category F2, the FLAME-X Power cables

listed met the requirements for fire resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 1994.

Certificate No: 814c to BS 6387: 1994, BS EN 50267-2-1: 1999 and IEC 60331-21: 1999

Flame-X 950 SingleNominal csa of conductor (mm²) Core

ConstructionBS 6387

(See Notes 2, 6 & 7)BS EN 50267-2-1 IEC 60331-21

(See Note 8)LPCB Ref. No.

1.5(1) One C, W, Z(3) <0.5%HCl Complies 814c/012.5(1) One C, W, Z(3) <0.5%HCl Complies4.0 (1) One C, W, Z(3) <0.5%HCl Complies6.0 (1) One C, W, Z(3) <0.5%HCl Complies10 (1) One C, W, Z(3) <0.5%HCl Complies16 (1) One C, W, Z(4,5) <0.5%HCl Complies25 (1) One C, W, Z(4,5) <0.5%HCl Complies35 (1) One C, W, Z(4,5) <0.5%HCl Complies50 (1) One C, W, Z(4,5) <0.5%HCl Complies70 (1) One C, W, Z(4,5) <0.5%HCl Complies95 (1) One C, W, Z(4,5) <0.5%HCl Complies

120 (1) One C(4) <0.5%HCl Complies150 (1) One C(4) <0.5%HCl Complies185 (1) One C(4) <0.5%HCl Complies240 (1) One C(4) <0.5%HCl Complies300 (1) One C(4) <0.5%HCl Complies400 (1) One C(4) <0.5%HCl Complies500 (1) One - <0.5%HCl Complies

Uo/U 600/1000V

Notes:1) Stranded conductor only.2) Clause 8 (Bending) and 9.1 & 9.2 (Impact) cannot be conducted due to the cable having only one core.3) To satisfy the requirement of BS 6387, testing for C, W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.4) To satisfy the requirement of BS 6387, testing for C category was conducted using a 38mm stainless steel conduit as the other

metallic element.5) To satisfy the requirement of BS 6387, testing for W & Z categories were conducted using a 20mm stainless steel conduit as the

other metallic element.6) These cables also met category C,W,Z when tested for voltage rating 600/1000V which is not recognised by BS 6387.7) Where a single cable is fitted in a conduit, only phase to earth voltage was applied.

Page 499: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 489

8) These cables met the requirements of IEC 60331-21: 1999 when tested at a temperature of 950oC and at a voltage rating of 600V.

Certificate No: 814e to BS 7846: 2000 This certificate is to a withdrawn version of the BS 7846: 2000. Cables conforming to this version of the standard may not be suitable for use within the jurisdiction of the European Union (EU).

FLAME-X-950 PowerNominal csa of

conductor (mm²)Core construction BS 7846 LPCB Ref. No.

1.5(1) 2, 3 & 4 F2(2,3) 814e/012.5(1) 2, 3 & 4 F2(2,3)

4.0(1) 2, 3 & 4 F2(2,3)

6.0(1) 2, 3 & 4 F2(2,3)

10(1) 2, 3 & 4 F2(2,3)

16(1) 2, 3 & 4 F2(2,3)

25(1) 2, 3 & 4 F2(2,3)

35(1) 2, 3 & 4 F2(2,3)

50(1) 2, 3 & 4 F2(2,3)

70(1) 2, 3 & 4 F2(2,3)

95(1) 2, 3 & 4 F2(2,3)

120(1) 2, 3 & 4 F2(2,3)

150(1) 2, 3 & 4 F2(2,3)

185(1) 2, 3 & 4 F2(2,3)

240(1) 2, 3 & 4 F2(2,3)

300(1) 2, 3 & 4 F2(2,3)

Uo/U 600/1000V

Notes:1) Stranded conductor only2) In meeting the requirements of BS 7846: 2000 Category F2, the FLAME-X Power cables listed met the requirements for fire

resistance characteristics Category CWZ specified in Clause 11 of BS 6387: 19943) BS 7846: 2000 was amended in 2004 to implement the changes to the identification of cores by colours, in accordance with the

CENELEC Harmonisation Document HD 308 S2. The un-amended version of the standard was withdrawn on 31st March 2006. However, cables with the old identification colours, meeting the withdrawn version of the standard, are still requested by some regulators outside of the EU. Certification to the un-amended version of the standard has therefore been maintained, for the time being, to satisfy the requirements of these regulators.

Certificate 814d covers cables certified in accordance with BS 7846: 2000 (Incorporating Amendments Nos. 1 & 2)

Tratos Cavi SpAVia Stadio 2, Pieve S. Stefano 52036, Arezzo, ItalyTel: +39 0575 7941 • Fax: +39 0575 798026E-mail: [email protected] • Website: www.tratos.it

Certificate No: 222a to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH30, BS 8434-1: 2003 30min & BS 5839-1: 2002 Clause 26.2d

FIRE-safe TW950 Fire Resistant CableNominal csaof conductor

(mm2)

CoreConstruction

(excluding drain

wire & earth)

BS 7629-1(Incorporating Amendments

Nos. 1 and 2)

BS EN 50200

BS 8434-1

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0 (1) 2, 3 & 4 Complies (3) Class PH30

30min(4) Standard(5) 222a/01

1.5 (1) 2, 3 & 4 Complies (3) Class PH30

30min(4) Standard(5)

2.5 (2) 2, 3 & 4 Complies (3) Class PH30

30min(4) Standard(5)

4.0 (2) 2, 3 & 4 Complies (3) Class PH30

30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.

Page 500: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

490 31 Dec 2012

2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), the FIRE-safe TW950 Fire Resistant

Cables listed met the requirements of smoke density of BS 7622-2: 1993, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the outer covering, binder tape & insulation when tested in accordance with BS 6425-1: 1990.

4) The duration of 30min when tested in accordance with BS 8434-1: 2003 is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase as described in Clause 26.2d) of BS 5839-1: 2002.

5) The FIRE-safe TW950 Fire Resistant Cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 and 2), met Class PH30 when tested in accordance with BS EN 50200: 2000 and met the 30min duration when tested in accordance with BS 8434-1: 2003 and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Certificate No: 222b to BS 7629-1: 1997 (Incorporating Amendments Nos. 1 & 2), BS EN 50200: 2000 Class PH120, BS 8434-2: 2003 120min & BS 5839-1: 2002 Clause 26.2e

Firesafe EnhancedNominal csaof conductor

(mm2)

CoreConstruction

(excluding drain

wire & earth)

BS 7629-1(Incorporating Amendments

Nos. 1 and 2)

BS EN 50200

BS 8434-2

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0 (1) 2, 3 & 4 Complies (3) Class PH120

120min (4) Enhanced(5)

222b/01

1.5 (1) 2, 3 & 4 Complies (3) Class PH120

120min (4) Enhanced(5)

2.5 (2) 2, 3 & 4 Complies (3) Class PH120

120min (4) Enhanced(5)

4.0 (2) 2, 3 & 4 Complies (3) Class PH120

120min (4) Enhanced(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 1997 (Incorporating Amendments Nos.1 & 2), the Firesafe Enhanced cables listed met the

requirements of smoke density of BS EN 50268-2: 2000, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape & outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 120min when tested in accordance with BS 8434-2: 2003 is achieved by 60min for the fire and impact phase and an additional 60min for the fire, impact and water phase as described in Clause 26.2 e) of BS 5839-1: 2002.

5) The Firesafe Enhanced cables listed conform to BS 7629-1: 1997 (Incorporating Amendments Nos.1 & 2), met Class PH120 when tested in accordance with EN 50200: 2000 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002.

Tyco Thermal Controls Canada Limited250 West Street, Trenton, Ontario K8V 5S2, CanadaTel: +613 392 6571 • Fax: +613 394 3711Website: www.tycothermal.com

Certificate No: 676a to BS EN 60702-1: 2002, BS 6387: 1994 and BS EN 50267-2-1: 1999

Pyrotenax Bare Mineral Insulated Cable (light duty)Nominal csa of

conductor (mm2)Core Construction

(see note 1)BS EN 60702-1

(see note 2)BS 6387

(see note 2)BS EN 50267-2-1 LPCB Ref. No.

1.0T 2 Complies C, W, Z <0.5%HCI 676a/011.0 2, 3, 4 & 7 Complies C, W, Z <0.5%HCI

1.5T 2, 3, 4 Complies C, W, Z <0.5%HCI1.5 2, 3, 4 & 7 Complies C, W, Z <0.5%HCI

2.5T 2, 3, 4 Complies C, W, Z <0.5%HCI2.5 2, 3, 4 & 7 Complies C, W, Z <0.5%HCI4.0 2 Complies C, W, Z <0.5%HCI

Uo/U300/500V

T = Twisted light duty

Page 501: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 491

Note:1) The above range is certified in bare construction only.

Certificate No: 676a to BS EN 60702-1: 2002, BS 6387: 1994 and BS EN 50267-2-1: 1999

Pyrotenax Bare Mineral Insulated Cable (single core heavy duty)Nominal csa of

conductor (mm2)Core Construction

(see note 1)BS EN 60702-1 BS 6387 BS EN 50267-2-1 LPCB Ref. No.

2.5 One Complies C, W, Z <0.5%HCI 676a/024.0 One Complies C, W, Z <0.5%HCI6.0 One Complies C, W, Z <0.5%HCI10 One Complies C, W, Z <0.5%HCI16 One Complies C, W, Z <0.5%HCI25 One Complies C, W, Z <0.5%HCI35 One Complies C, W, Z <0.5%HCI50 One Complies C, W, Z <0.5%HCI70 One Complies C, W, Z <0.5%HCI95 One Complies C, W, Z <0.5%HCI

120 One Complies C, W, Z <0.5%HCI150 One Complies C, W, Z <0.5%HCI185 One Complies C, W, Z <0.5%HCI240 One Complies C, W, Z <0.5%HCI300 One Complies C, W, Z <0.5%HCI

Uo 450V

Note:1) The above range is certified in bare construction only.2) For single core cables, only phase to earth voltage was applied.

Certificate No: 676a to BS EN 60702-1: 2002, BS 6387: 1994 and BS EN 50267-2-1: 1999

Pyrotenax Bare Mineral Insulated Cable (heavy duty)Nominal csa of

conductor (mm2)Core Construction

(see note 1)BS EN 60702-1 BS 6387 BS EN 50267-2-1 LPCB Ref. No.

1.5 2, 3, 4, 7, 12 & 19 Complies C, W, Z <0.5%HCI 676a/032.5 2, 3, 4, 7 & 12 Complies C, W, Z <0.5%HCI4.0 2, 3, & 4 Complies C, W, Z <0.5%HCI6.0 2, 3, & 4 Complies C, W, Z <0.5%HCI10 2, 3, & 4 Complies C, W, Z <0.5%HCI16 2, 3, & 4 Complies C, W, Z <0.5%HCI25 2, 3, & 4 Complies C, W, Z <0.5%HCI

Uo/U 450/750V

Note:1) The above range is certified in bare construction only.

Tyco Thermal Controls UK Ltd3 Rutherford Road, Stephenson Industrial Estate, Washington, Tyne & Wear NE37 3HX, United KingdomTel: +44 (0)191 419 8200 • Fax: +44 (0)191 419 8201E-mail: [email protected] • Website: www.tycothermal.com

Certificate No: 063d to BS EN 60702-1: 2002, BS 6387: 1994, BS EN 50267-2-1: 1999, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003+A2:2009 and BS 5839-1: 2002+A2:2008 Clause 26.2e

PYRO MI Mineral Insulated CablesNominal csa of

conductor (mm2)

Core Construction

BS EN 60702-1 (see note 6)

BS 6387

BS EN 50267-2-1 (outer covering)

BS EN 50200

BS 8434-2

BS 5839-1 Clause 26.2

LPCB Ref. No.

PYRO MI Light Duty

063d/01

Page 502: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

492 31 Dec 2012

Nominal csa of

conductor (mm2)

Core Construction

BS EN 60702-1 (see note 6)

BS 6387

BS EN 50267-2-1 (outer covering)

BS EN 50200

BS 8434-2

BS 5839-1 Clause 26.2

LPCB Ref. No.

1.0(1,2) 2, 3, 4 & 7 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

1.5(1,2) 2, 3, 4 & 7 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

2.5(1,2) 2, 3, 4 & 7 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

4.0(1,2) 2 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

PYRO MI Heavy Duty

1.5(1,3) one, 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

1.5(1,3) 7, 12 & 19 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

2.5(1,3) one, 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

2.5(1,3) 7 & 12 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

4.0(1,3) one, 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

6.0(1,3) one, 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

10(1,3) one, 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

16(1,3) one, 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

25(1,3) one, 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

35(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

50(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

70(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

95(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

120(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

150(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

185(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

240(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

300(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

400(1,3) one Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

PYRO MI Twisted Light

Duty1.0T(1,2) 2 Complies(4) C, W,

Z(4)<0.5% HCl(5) Class

PH120(5)120min(5) Enhanced(5,7)

1.5T(1,2) 2, 3 & 4 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

2.5T(1,2) 2 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

4.0T(1,2) 2 Complies(4) C, W, Z(4)

<0.5% HCl(5) Class PH120(5)

120min(5) Enhanced(5,7)

Notes:1) Solid conductor only.2) The PYRO MI Mineral Insulated Light Duty Cables were tested at a voltage rating of 300/500V.3) The PYRO MI Mineral Insulated Heavy Duty Cables were tested at a voltage rating of 450/750V.4) Approval applies to the Bare and Served cables.5) Approval applies to the Served cable only.6) In meeting the requirements of BS EN 60702-1: 2002, the PYRO MI Mineral Insulated Served Cables listed met the requirements of

smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997.

Page 503: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 493

7) The PYRO MI Mineral Insulated Served Cables listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003+A2:2009 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Union Cable Company LtdUnit 15, Faraday Road, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1QF, United KingdomTel: +44 (0)1928 577 418 • Fax: +44 (0)1928 581 [email protected]: [email protected] • Website: www.unioncable.co.uk

Certificate No: 682a-(cl-2) to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120,BS EN50200: 2006 Annex E and BS 5839-1: 2002+A2:2008 Clause 26.2d

Firetrax GoldNominal csaof conductor

(mm 2)

CoreConstruction

(excluding drainwire & earth)

BS 7629-1 BS EN 50200 BS EN 50200Annex E

BS 5839-1Clause 26.2

LPCB Ref. No.

1.0 (1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5) 682a/011.5 (1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

2.5 (1) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

4.0 (2) 2, 3 & 4 Complies(3) Class PH120 30min(4) Standard(5)

Uo/U 300/500V

Notes:1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the Firetrax Gold cables listed met the requirements of smoke density of BS EN

61034-2: 2005 fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1:1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase and an additional 15min for the fire, impact and water phase.

5) The Firetrax Gold cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2: 2008.

Ventcroft LimitedFaraday Road, Astmoor Industrial Estate, Runcorn, Cheshire WA7 1PE, United KingdomTel: +44 (0)1928 581098 • Fax: +44 (0)1928 581099E-mail: [email protected] • Website: www.ventcroft.co.uk

Certificate No: 682a to BS 7629-1: 2008, BS EN 50200: 2006 Class PH120, BS EN 50200:2006 Annex E and BS 5839-1:2002+A2:2008 Clause 26.2d

NoBurn PlatinumNominal

csaof

conductor(mm2)

CoreConstruction

(excluding drain wire & earth)

BS 7629-1 BS EN 50200

BS EN 50200 Annex E

BS 5839-1Clause

26.2

LPCB Ref. No.

1.0(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5) 682a/01

1.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

2.5(1) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

4.0(2) 2, 3 & 4 Complies(3) Class PH120

30min(4) Standard(5)

Uo/U 300/500V

Notes:

Page 504: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

494 31 Dec 2012

1) Solid conductor only.2) Stranded conductor only.3) In meeting the requirements of BS 7629-1: 2008, the NoBurn Platinum cables listed met the requirements of smoke density of

BS EN 61034-2: 2005, fire resistance requirements CWZ in Clause 11 of BS 6387: 1994 and achieved less than 0.5%HCl on the insulation, binder tape and outer covering when tested in accordance with BS EN 50267-2-1: 1999.

4) The duration of 30min when tested in accordance with BS EN 50200: 2006 Annex E is achieved by 15min for the fire and impact phase.

5) The NoBurn Platinum cables listed conform to BS 7629-1: 2008, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met the 30min duration when tested in accordance with BS EN 50200: 2006 Annex E and hence met the requirements for a standard fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2: 2008.

Wrexham Mineral CablesWynnstay Technology Park, Ruabon, Wrexham, Clwyd LL14 6EN, United KingdomTel: +44 (0)1978 810789 • Fax: +44 (0)1978 821502E-mail: [email protected] • Website: www.wrexhammineralcables.com

Certificate No: 333a to BS EN 60702-1: 2002, BS 6387: 1994, BS 50267-2-1: 1999, BS EN 50200: 2006 Class PH120, BS 8434-2: 2003 120 min and BS 5839-1: 2002+A2:2008 Clause 26.2e

Wrexham Mineral Insulated CablesNominal csa of conductor

(mm2)

Core Construction

BS EN 60702-1 (See

note 6)

BS 6387

BS EN 50267-2-1

(outer covering)

BS EN 50200 BS 8434-2

BS 5839-1 Clause 26.2

LPCB Ref. No.

WMIC Light Duty

333a/01

1.0(1,2) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

1.5 (1,2) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

2.5(1,2) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

4.0(1,2) 2 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

WMIC Heavy Duty

1.5(1,3) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

2.5(1,3) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

4.0(1,3) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

6.0(1,3) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

10(1,3) 2 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

WMIC Twisted Light

Duty 1.0T(1,2) 2 Complies(4) C,W,Z(4) <0.5%

HCl(5)Class/PH120(5) 120min(5) Enhanced(5,7)

1.5T(1,2) 2, 3 & 4 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

2.5T(1,2) 2 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

4.0T(1,2) 2 Complies(4) C,W,Z(4) <0.5% HCl(5)

Class/PH120(5) 120min(5) Enhanced(5,7)

Notes:1) Solid conductor only.2) The Wrexham Mineral Insulated Light Duty Cables were tested at a voltage rating of 300/500V.3) The Wrexham Mineral Insulated Heavy Duty Cables were tested at a voltage rating of 450/750V.4) Approval applies to the Bare and Served cables.5) Approval applies to the Served cable only.6) In meeting the requirements of BS EN 60702-1: 2002, the Wrexham Mineral Insulated Served Cables listed met the requirements of

smoke density of IEC 61034-2: 2005 and also met the requirements of pH & conductivity when tested in accordance with IEC 60754-2-am1: 1997.

Page 505: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 8FIRE RESISTANT CABLES

31 Dec 2012 495

7) The Wrexham Mineral Insulated Served Cables listed conform to BS EN 60702-1: 2002, met Class PH120 when tested in accordance with BS EN 50200: 2006 and met a duration of 120min when tested in accordance with BS 8434-2: 2003 and hence met the requirements for an Enhanced fire resistant cable as described in Clause 26.2 of BS 5839-1: 2002+A2:2008.

Page 506: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 9ALARM RECEIVING CENTRES

496 31 Dec 2012

This section lists Alarm Receiving Centres approved to LPS 1020 Requirements for Alarm Receiving Centres and those certified to the requirements of BS 5979 Code of Practice for Remote Centres Receiving Signals from Security Systems.

The Fire Service’s 'Model Agreement' between the Fire and Rescue authorities and users of remotely monitored fire alarm systems calls for third party certification of both the installer and the Alarm Receiving Centre (ARC).

The LPCB approval scheme based on the criteria of LPS 1020 when used in conjunction with BS 5979 provides the means to achieve the alarm receiving centre requirement of the model agreement. Third party certification of the installer can be achieved via the LPCB’s scheme for installers based, on the requirements of LPS 1014 Requirements for certificated fire detection and alarm systems firms.

For further details of the ‘Model Agreement’ contact:-

The Chief Fire Officers’ Association9-11 Pebble CloseAmingtonTamworthStaffordshireB77 4RDTel: +44 (0) 1827 302 300

Since the Alarm Receiving Centres must have links to the appropriate fire brigade mobilisation centres, the list includes details of the fire authority areas for which they are approved.

LPS 1020 is in the process of being revised. Please check www.RedBookLive.com for updates.

Banham Alarms (Prop: Banham Patent Locks Limited)10 Pascal Street, London SW8 4SH, United KingdomTel: +44 (0)207 622 5151 • Fax: +44 (0)207 498 2461Website: www.banham.com

Certificate No. CFSA006 to LPS 1020

Alarm receiving equipment: Telecom Red CARE System.

Approved Fire Authority areas of operation:Bedfordshire, Berkshire, Buckinghamshire, East Sussex, Essex, Hampshire, Hertfordshire, Kent, Greater London, Surrey West Sussex.

EMCS - East Midlands Central Station LimitedWaterside House, Tissington Close, Chilwell, Nottingham NG9 6QG, United KingdomTel: +44 (0)844 80 999 80 • Fax: +44 (0)844 80 999 70E-mail: [email protected] • Website: www.emcs.co.uk

Certificate No. CFSA 017 to LPS 1020 Issue 2.1

Alarm receiving equipment: BT Redcare (Incorporating Classic,GSM,AGILE and ASSURE), CSL Dualcom, Emizon21, Webway One Digital Communicators, (Point Id and SIA communication Protocols) CCTV - Adpro, DM and VDT.

Approved fire authority areas of operation: Avon, Bedfordshire, Berkshire, Buckinghamshire, Cambridgeshire, Central Scotland, Cheshire, Cleveland, Cornwall, Cumbria, Derbyshire, Devon, Dorset, Dumfries & Galloway, Durham, Dyfed, East Sussex, Essex, Fife, Gloucestershire, Grampian, Guernsey, Hampshire, Hereford & Worcester, Hertfordshire, Highlands & Islands, Humberside, Isle Of Man, Isle Of Wight, Kent, Lancashire, Leicester, Lincolnshire, London, Lothian & Borders, Manchester, Merseyside, Mid/West Wales, Norfolk, North Wales, North Yorkshire, Northants, Northern Ireland, Northumberland, Oxfordshire, Powys, Shropshire, Somerset, South Wales, South Yorkshire, Staffordshire, Strathclyde, Suffolk, Surrey, West Sussex, Tayside, Tyne & Wear, Warwickshire, West Midlands, West Yorkshire, Wiltshire.

Page 507: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 9ALARM RECEIVING CENTRES

31 Dec 2012 497

National Monitoring (Prop. AVR Group Limited)Units 16/24, Attenburys Park Estate, Attenburys Lane, Timperley, Cheshire WA14 5QN, United KingdomTel: +44 (0)870 4009998 • Fax: +44 (0)870 4009988

Certificate No. CFSA008 to LPS 1020

Alarm receiving equipment: Telecom Red CARE System.

Approved fire authority areas of operation:Avon, Bedfordshire, Berkshire, Cambridgeshire, Cheshire, Clwyd, Cumbria, Derbyshire, Devon, Dorset, Essex, Gloucestershire, Hampshire, Hereford & Worcester, Humberside, Lancashire, Leicestershire, Lincolnshire, London, Greater Manchester, Merseyside, Norfolk, Northamptonshire, Northern Ireland, Nottinghamshire, North Yorkshire, Shropshire, South Yorkshire, Staffordshire, Suffolk, Surrey, Tyne and Wear Warwickshire, West Glamorgan, West Midlands, West Yorkshire, Strathclyde.

Southern Monitoring Services LimitedSecurity House, 212-218, London Road, Waterlooville, Hampshire PO7 7AJ, United KingdomTel: +44 (0)844 871 2223 • Fax: +44 (0)870 243 330

Certificate No. CFSA003 to LPS 1020

Alarm receiving equipment: Telecom Red CARE System.

Approved fire authority areas of operation:Avon, Bedfordshire, Berkshire, Buckinghamshire, Cambridgeshire, Cheshire, Cleveland, Clwyd, Cornwall, Cumbria, Derbyshire, Devon, Dorset, East Sussex, Essex, Gloucestershire, Grampian, Greater London, Gwent, Hampshire, Hereford & Worcester, Hertfordshire, Humberside, Isle of Wight, Kent, Lancashire, Leicestershire, Lincolnshire, Lothian, Greater Manchester, Merseyside, Mid Glamorgan, Norfolk, Northamptonshire, North Yorkshire, Nottinghamshire, Oxfordshire, Powys, Shropshire, Somerset, South Glamorgan, South Yorkshire, Staffordshire, Strathclyde, Suffolk, Surrey, Tyne & Wear, Warwickshire, West Glamorgan, West Midlands, West Sussex, West Yorkshire, Wiltshire.

Page 508: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10ALARM TRANSMISSION AND FAULT MONITORING EQUIPMENT AND SIGNALLING SYSTEMS

498 31 Dec 2012

Alarm transmission and fault monitoring equipment and signalling systems

This section of the Red Book lists alarm transmission and fault warning routing equipment suitable for use with fire alarm systems as defined by Figure 1 of EN 54-1: 1996 Fire detection and fire alarm systems Part 1.

Alarm transmission equipment suitable for use with intruder alarm and hold-up systems are listed in Volume 2, Part 4, Section 1.2 of the Red Book.

Where alarm transmission equipment may be suitable for use with both fire alarm systems and intruder alarm and hold-up systems the entry for the approved equipment will appear in Volume 1, Part 1, Section 10 and Volume 2, Part 4, Section 1.2 of the Red Book.

Where appropriate, reference is made to published standards and the following standards are currently used for the approval schemes:

EN 54-21: 2006 Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment

LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems andEquipment

EN 54-21: 2006 is a harmonised standard for the Construction Products Directive. Compliance with the EN standard entitles the equipment manufacturer to apply the CE mark and is mandatory in many countries within the EU.

ANNEX ZA of EN 54-21 states that for CE marking purposes it is not necessary to test the alarm transmission and fault routing equipment performance characteristics in conjunction with the transmission networks to confirm the claimed transmission parameters D, M, T, A ,S and I. These parameters are however described in the EN 54-21 normative ANNEX A and may be tested as an option. Unless otherwise stated LPCB approval to EN 54-21 confirms that the routing equipment meets only those requirements of ANNEX ZA relating to the operational and environmental reliability of the item(s) located within the protected premises.

Whereas LPS 1277 includes criteria for both fire and security systems that specifically requires the alarm transmission and fault routing equipment to be tested in conjunction with the appropriate transmission networks. Particular emphasis is placed on the verification of manufacturers’ claims by measuring alarm transmission times over the transmission path(s) between the equipment under test and the corresponding alarm receiving centre. The response to the reporting of fault conditions is measured in a similar way. The results of these measurements are expressed in terms of alarm transmission system (ATS) performance criteria classification, using the parameters D, M, T and where applicable S and I.

Where,D = Transmission time classificationM = Transmission time maximum valuesT = Reporting time classificationS = Substitution SecurityI = Information Security

Availability is considered a key parameter under LPCB approval and is therefore included within the requirements of LPS 1277 and the resultant performance is expressed using the parameter ‘A’ for Availability.

To assist specifiers in their selection of the products most appropriate for protecting their risks, the actual performance parameters measured during the LPCB test programme are included with the product listing entry in the Redbook as an indicator of the level of performance that can be expected from the alarmtransmission system.

Products approved to LPS 1277 Issue 3.0 encompass all of the requirements of EN 54-21 and products tested and approved by the LPCB will have met the compliance criteria of EN 54-21 in full. It is therefore recommended that alarm transmission and fault routing equipment be approved to LPS 1277 where possible.

Page 509: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10ALARM TRANSMISSION AND FAULT MONITORING EQUIPMENT AND SIGNALLING SYSTEMS

31 Dec 2012 499

Compliance with relevant safety standards and applicable mandatory directives is a pre-requisite of LPCB approval and listing. Regular product auditing and regular factory inspections are carried out by LPCB ensuring high manufacturing standards and continued compliance with the applicable product standard.

Notes:Since the LPCB uses national and international standards for the listing of products, in some instances the requirements of these standards may conflict with the recommendations of local codes of practice. We recommend that specifiers seek advice from the relevant local authorities and amend their specifications accordingly.

Page 510: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10.1ALARM TRANSMISSION AND FAULT WARNING ROUTING EQUIPMENT

500 31 Dec 2012

Alarm transmission and fault warning routing equipment

Alarm transmission and fault warning routing equipment approved to the requirements of EN 54-21: 2006 Fire detection and fire alarm systems - Part 21: Alarm transmission and fault warning routing equipment.

Unless stated otherwise the performance of those components of the alarm transmission and fault monitoring system normally located in the protected premises have been tested and assessed for compliance without connection to the associated alarm transmission networks as prescribed by ANNEX ZA of EN 54-21.

Please check www.RedBookLive.com for updates.

Page 511: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10.2SUPERVISED PREMISES TRANSCEIVERS (FIRE) - LPS 1277 ISSUE 2.2

31 Dec 2012 501

Supervised premises transceivers (fire) - LPS 1277 Issue 2.2

Supervised premises transceivers are part of the alarm transmission and fault warning equipment. They are located at the protected premises and are connected between the transmission network and the fire alarm control panel.

The equipment listed in this section has been assessed against the requirements and test methods of LPS 1277 Requirements for LPCB Approval and listing of Alarm Transmission Systems and Equipment Issue 2.2.

CAUTION - LPS 1277 ISSUE 2.2 WAS SUPERSEDED IN APRIL 2011 BY LPS 1277 ISSUE 3.0. See Part 1 Section 10.3.

Please check www.RedBookLive.com for the current publication and for the latest product listings.

BT RedcareMonument TE, 11-13 Great Tower Street, London EC3R 5EA, United KingdomTel: +44 (0) 800 800 828 • Fax: +44 (0)20 7929 6490Website: www.redcare.bt.com

Certificate No: 775a to LPS 1277 Issue 2.2

Supervised Premises Transceivers (Fire) - LPS 1277 Issue 2.2Certificated Products LPCB Ref.

No.UC-372G-UK ASSURE STAR

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver. 775a/01

For full details of the approval, you can view a pdf of the certificate by clicking on the product name in the entry on www.RedBookLive.com.

CSL DualCom LimitedSalamander Quay West, Park Lane, Harefield, Middlesex UB8 6NZ, United KingdomTel: +44 (0)1895 474474 • Fax: +44 (0)1895 474440E-mail: [email protected] • Website: www.csldual.com

Certificate No: 723a to LPS 1277: Issue 2.2

Supervised Premises Transceivers (Fire) - LPS 1277 Issue 2.2Certificated Products LPCB Ref.

No.CS 1400 DualCom Fire A dual path, GPRS (Primary) and PSTN (Secondary) supervised premises transceiver. 723a/01

For full details of the approval, you can view a pdf of the certificate by clicking on the product name in the entry on www.RedBookLive.com.

Page 512: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10.3SUPERVISED PREMISES TRANSCEIVERS (FIRE) - LPS 1277 ISSUE 3

502 31 Dec 2012

Supervised premises transceivers are part of the alarm transmission and fault warning equipment. They are located at the protected premises and are connected between the transmission network and the fire alarm control panel.

Specifiers are advised to check the issue of LPS 1277 against which the supervised premises transceiver is approved. The current publication of LPS 1277 is Issue 3.

Chiron Security Communications LimitedWyvols Court, Swallowfield, Reading, Berkshire RG7 1WY, United KingdomTel: +44 (0)118 988 0228 • Fax: +44 (0)118 988 1055E-mail: [email protected] • Website: www.chironsc.com

Certificate No: 1080a to LPS 1277 Issue 3.0

Supervised premises transceivers (fire) - LPS 1277 Issue 3.0Certificated Products LPCB Ref.

No.Iris Touch 220 Alarm transmission dialler

A single path, Ethernet supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Fire Type 1 1 fire alarm transmission and fault warning routing equipment.

1080a/02

Iris Touch 240 Alarm transmission dialler

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1080a/03

Iris Touch 420 Alarm transmission dialler

A single path, Ethernet supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1080a/05

Iris Touch 440 Alarm transmission dialler

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1080a/06

Iris Touch 440R Alarm transmission dialler

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1080a/07

Iris Touch 440R Alarm transmission dialler

A dual path, Ethernet (GPRS) and PSTN (secondary) supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 21 fire alarm transmission and fault warning routing equipment.

1080a/07

Iris Touch 620 Alarm transmission dialler

A single path, Ethernet supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1080a/08

Iris Touch 640 Alarm transmission dialler

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1080a/09

Notes:1. To achieve fire category 'BS EN 54-21 Type 1' or 'BS EN 54-21 Type 2' for use with fire detection and alarm systems, the following

requirements must be observed:

The IRIS Touch configuration settings must be set as stated in Section 3.1, ‘Requirements for the monitoring centre’, of the ‘Touch Dialler Installation Manual for EN 54-21 Compliant Fire Applications’ V1.0, to provide the performance parameters shown in the Confirmed Performance Parameters tables.

The dialler must be fitted within the fire alarm control and indicating equipment (CIE) or other metal housing providing protection against ingress to IP30 at access level 2 and be connected to an integral power supply compliant with BS EN 54-4 (Chiron recommends the use of the Elmdene ‘ST’ range of power supplies if required).

The dialler must be used in conjunction with fire alarm CIE which is capable of meeting 'options with requirements' associated with clauses 7.9, 8.2.4(g), 8.2.5(b), 8.9, 9.4.1(c), 9.4.2(b), 10.1(e), 11(a) and 11(b) of BS EN 54-2.

Connection to the fire alarm CIE shall be by PIN inputs only with end-of-line resistors fitted.

For full details of the approval, you can view a pdf of the certificate by clicking on the product name in the entry on www.RedBookLive.com.

Page 513: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10.3SUPERVISED PREMISES TRANSCEIVERS (FIRE) - LPS 1277 ISSUE 3

31 Dec 2012 503

Chubb Fire and Security LimitedUnit B, 3A Edison Road, Hams Hall Distribution Park, Coleshill, Birmingham B46 1DA, United KingdomTel: +44 (0)800 321666 • Fax: +44 (0)1932 765630E-mail: [email protected] • Website: www.chubb.co.uk

Sales Enquiries:Chubb Fire & Security ltd, Chubb House, Staines Road West, Sunbury on Thames, Middlesex TW16 7AR, United KingdomTel: +44 (0)800 321666 • Fax: +44 (0)1932 765630E-mail: [email protected] • Website: www.chubb.co.uk

Certificate No: 1078a to LPS 1277: Issue 3.0

Supervised premises transceivers (fire) - LPS 1277 Issue 3.0Certificated Products LPCB Ref.

No.20118530 Chubb eConnect IP/GPRS G4eF

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1078a

Notes:1. To achieve fire category 'BS EN 54-21 Type 1' for use with fire detection and alarm systems, the following requirements must be

observed:

The 20118530 - Chubb eConnect IP/GPRS G4eF is to be used in accordance with the installation instructions and in conjunction with fire alarm CIE which is capable of meeting 'options with requirements' associated with clauses 7.9, 8.2.4(g), 8.2.5(b), 8.9, 9.4.1(c), 9.4.2(b), 10.1(e), 11(a) and 11(b) of BS EN 54-2.

Fire alarm and fire fault or trouble signals from the alarm panel must be connected via PIN inputs. The PIN inputs shall be programmed as ‘End of Line’ (EOL).

The 20118530 - Chubb eConnect IP/GPRS G4eF must be fitted within the fire alarm control and indicating equipment (CIE) or other metal housing providing protection against ingress to IP30 at access level 2 and be connected to an integral power supply compliant with BS EN 54-4.

The fault outputs must be connected to suitable inputs on an BS EN 54-2 compliant fire alarm CIE. The CIE inputs must be electrically compatible with the eConnect IP/GPRS G4eF outputs as defined by the electrical specifications section of the Chubb eConnect IP/GPRS G4eF installation manual. If compatibility cannot be achieved a BS EN 54 compliant supplementary interface should be used.

Where the use of additional interface equipment is required to connect with a particular fire alarm CIE, this must be compliant with the applicable part(s) of BS EN 54.

Fault conditions signalled by general purpose fault output 1, must be latched by the CIE fault input circuit.

For full details of the approval, you can view a pdf of the certificate by clicking on the product name in the entry on www.RedBookLive.com.

UTC Fire & Security BV.Kelvinstraat 7, 6003 DH Weert, The NetherlandsTel: +31 495 583000 • Fax: +31 495 550042E-mail: [email protected] • Website: www.utcfssecurityproducts.nl

Certificate No: 1062c to LPS 1277: Issue 3.0

Supervised premises transceivers (fire) - LPS 1277 Issue 3.0Certificated Products LPCB Ref.

No.TDA1420 Alarm transmission dialler

A single path1, Ethernet supervised premises transceiver, capable of fulfilling:-The requirements of BS EN 54-21 for Type 12 fire alarm transmission and fault warning routing equipment.

1062c/02

Page 514: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10.3SUPERVISED PREMISES TRANSCEIVERS (FIRE) - LPS 1277 ISSUE 3

504 31 Dec 2012

Certificated Products LPCB Ref. No.

TDA1440 Alarm transmission dialler

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver capable of fulfilling:-The requirements of BS EN 54-21 for Type 12 fire alarm transmission and fault warning routing equipment.

1062c/03

Notes:1. If a single transmission path is to be used for fire applications, careful consideration should be given to the selection of a network for

which an appropriate level of robustness and stability can be assured.2. To achieve fire category 'BS EN 54-21 Type 1’ for use with fire detection and alarm systems, the following requirements must be

observed:- The TDA dialler configuration settings must be set as stated in the ‘Dialler installation for BS EN 54-21 compliant fire applications’

section of the TDA14xx Series Dialler Installation Manual, issue 1, in order to provide the performance parameters shown in the Confirmed Performance Parameters tables.

- The dialler must be fitted within the fire alarm control and indicating equipment (CIE) or other metal housing providing protection against ingress to IP30 at access level 2 and be connected to an integral power supply compliant with BS EN 54-4 (UTC recommends the use of the UTC PM702C and PM705C power supplies if required).

- The dialler must be used in conjunction with fire alarm CIE which is capable of meeting 'options with requirements' associated with clauses 7.9, 8.2.4(g), 8.2.5(b), 8.9, 9.4.1(c), 9.4.2(b), 10.1(e), 11(a) and 11(b) of BS EN 54-2.

- Connection to the fire alarm CIE shall be by PIN inputs only with end-of-line resistors fitted.

For full details of the approval, you can view a pdf of the certificate by clicking on the product name in the entry on www.RedBookLive.com

WebWayOne Ltd11 Kingfisher Court, Hambridge Road, Newbury, Berkshire RG14 5SJ, United KingdomTel: +44 (0)1635 231500 • Fax: +44 (0)1635 231539E-mail: [email protected] • Website: www.webwayone.co.uk

Certificate No: 1022a/01 to LPS 1277 Issue 3.0

Supervised premises transceivers (fire) - LPS 1277 Issue 3.0Certificated Products LPCB Ref.

No.22-5005 WebWay IP/GPRS LPS Fire Type 1 plus configuration part number 1411AD155001

A dual path, Ethernet (primary) and GPRS (secondary) supervised premises transceiver capable of fulfilling:-The requirements of BS EN 54-21 for Type 11 fire alarm transmission and fault warning routing equipment.

1022a/01

Notes:1. To achieve fire category 'BS EN 54-21 Type 1' for use with fire detection and alarm systems, the following requirements must be

observed:

The 22-5005 WebWay IP/GPRS LPS Fire Type 1 supervised premises transceiver is to be used in accordance with the installation instructions and in conjunction with fire alarm CIE which is capable of meeting 'options with requirements' associated with clauses 7.9, 8.2.4(g), 8.2.5(b), 8.9, 9.4.1(c), 9.4.2(b), 10.1(e), 11(a) and 11(b) of BS EN 54-2.

Fire alarm and fire fault or trouble signals from the alarm panel must be connected via PIN inputs. The PIN inputs shall be programmed as ‘End of Line’ (EOL).

The 22-5005 WebWay IP/GPRS LPS Fire Type 1 supervised premises transceiver must be fitted within the fire alarm control and indicating equipment (CIE) or other metal housing providing protection against ingress to IP30 at access level 2 and be connected to an integral power supply compliant with BS EN 54-4.For full details of the approval, you can view a pdf of the certificate by clicking on the product name in the entry on www.RedBookLive.com.

Certificate No: 1022a/02 to LPS 1277: Issue 3.0

Supervised premises transceivers (fire) - LPS 1277 Issue 3.0Certificated Products LPCB Ref.

No.22-5015 WebWay GPRS/PSTN LPS Fire Type 2 plus configuration part number 1411AD155003

A dual path, GPRS (primary) and PSTN (secondary) supervised premises transceiver capable of fulfilling:-The requirements of BS EN 54-21 for Type 21 fire alarm transmission and fault warning routing equipment.

1022a/02

Page 515: Last updated: 31 Dec 2012·راحي سيستم هاي اعلام حريق/CD1/REDBOOK... · can still rely on the products carrying the old mark where their certificate was issued

PART 1: SECTION 10.3SUPERVISED PREMISES TRANSCEIVERS (FIRE) - LPS 1277 ISSUE 3

31 Dec 2012 505

Notes:1) To achieve fire category 'BS EN 54-21 Type 2' for use with fire detection and alarm systems, the following requirements must be

observed:

The 22-5015 WebWay GPRS/PSTN LPS Fire Type 2 supervised premises transceiver is to be used in accordance with the installation instructions and in conjunction with fire alarm CIE which is capable of meeting 'options with requirements' associated with clauses 7.9, 8.2.4(g), 8.2.5(b), 8.9, 9.4.1(c), 9.4.2(b), 10.1(e), 11(a) and 11(b) of BS EN 54-2.

Fire alarm and fire fault or trouble signals from the alarm panel must be connected via PIN inputs. The PIN inputs shall be programmed as ‘End of Line’ (EOL).

The 22-5015 WebWay GPRS/PSTN LPS Fire Type 2 supervised premises transceiver must be fitted within the fire alarm control and indicating equipment (CIE) or other metal housing providing protection against ingress to IP30 at access level 2 and be connected to an integral power supply compliant with BS EN 54-4.

For full details of the approval, you can view a pdf of the certificate by clicking on the product name in the entry on www.RedBookLive.com.