laser imaging sf6 6 inspection inspection for chicago ...€¦ · #29 machine – – copper...
TRANSCRIPT
Laser Imaging SFLaser Imaging SF66 InspectionInspection forfor
Chicago White Metal Casting, Inc.Chicago White Metal Casting, Inc.
Mixing stationMixing station
Mixing station inspectionMixing station inspection
Mixing stationMixing station
Confirmed regulator leak Confirmed regulator leak using soap testusing soap test
Regulator flange leakRegulator flange leak Tightened screws and leak stoppedTightened screws and leak stopped
Confirmed solenoid valve leakConfirmed solenoid valve leak using soap testusing soap test
Solenoid valve leakSolenoid valve leak Replaced valve Replaced valve –– leak stoppedleak stopped
Central distribution line inspectionCentral distribution line inspection
Service corridorService corridor
Service corridor branch line inspectionService corridor branch line inspection
Flow meter inspectionFlow meter inspection
#21 Machine #21 Machine -- feed tube flared fittingfeed tube flared fitting
#21 Machine #21 Machine -- feed tube flared fittingfeed tube flared fitting
#26 Machine #26 Machine –– feed tube flared fittingfeed tube flared fitting
#26 Machine #26 Machine –– feed tube flared fittingfeed tube flared fitting Tightened fitting Tightened fitting –– leak stoppedleak stopped
#29 Machine #29 Machine –– copper fitting leakcopper fitting leak
#29 Machine #29 Machine –– copper fitting leakcopper fitting leak Tightened Tightened –– leak stoppedleak stopped
Shaft seal leaking on all machines Shaft seal leaking on all machines
Shaft seal leakingShaft seal leaking
New design feed lineNew design feed line
Hard at workHard at work