lascr
DESCRIPTION
Light –Activated Silicon-Controlled RectifierTRANSCRIPT
![Page 1: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/1.jpg)
Name : Mohsin Rauma Roll no. : 9 Sem. : 4th
![Page 2: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/2.jpg)
![Page 3: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/3.jpg)
it is an SCR whose state is controlled by the light falling upon a silicon semiconductor layer of the device.
![Page 4: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/4.jpg)
![Page 5: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/5.jpg)
Anode
Gate
Cathode
Anode
Cathode
Gate
![Page 6: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/6.jpg)
Some of the areas of application for the LASCR include optical light controls, relays, phase control, motor control and a variety of computer application
The maximum currents (rms) and power (gate) ratings for LASCRs commercially available today are about 3A and 0.1W.
One interesting application of an LASCR is in the AND and OR circuits
![Page 7: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/7.jpg)
Load
LASCR1
LASCR2
Supply
![Page 8: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/8.jpg)
Load
Supply
LASCR1 LASCR2
![Page 9: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/9.jpg)
The LASCR is most sensitive to light when the gate terminal is open. It’s sensitivity can be reduced and controlled somewhat by the insertion of the gate resistor.
It is the semiconductor analog of the electromechanical relay.
It offers complete isolation between input and switching element.
The energizing current can be passed through a light-emitting diode or a lamp.
Dc input
load
S1
dc
![Page 10: LASCR](https://reader030.vdocuments.us/reader030/viewer/2022033017/55cf9c47550346d033a94829/html5/thumbnails/10.jpg)
The incident light will cause the LASCR to turn on and permit a flow of charge through the road as establish by the Dc supply. The LASCR can be turned off using the reset switch.
This system offers the additional advantage over an electromechanical switch of long life microsecond response, small size, and the elimination of contact bounce.