lap siding installation guide - cedarshinglesdirect.com › ... › 2015 › 04 ›...

6
MaxiSOFFIT TM to ASTM E-136, with zero me spread in accordance to ASTM E-184. MaxiSOFFIT TM MaxiSOFFIT TM STORAGE AND HANDLING: Protect from the weather. Use the plastic cover that is provided with the pallet to keep product dry. MaxiSOFFIT TM is produced with a factory-applied primer; this primer does not provide adequate resistance to moisture in the event the product is allowed to become saturated during storage. If MaxiSOFFIT TM becomes wet or saturated, allow product to dry before installation. Store product dry and flat prior to installation. Installing MaxiSOFFIT TM wet or saturated may cause shrinkage at butt joint, which could produce breakage at corners. Protect edges and corners from chipping. Carry panels on edge. MAXITILE is not responsible for damage caused by improper storage and / or handling of the product . LAP SIDING INSTALLATION GUIDE MaxiSOFFIT TM It will not rot or deteriorate. It is non-combustible in accordance is available in ¼” (6 mm) nominal thickness in two types: Vented (V) and Non-Vented (NV), in two textures, Smooth and Classic Cedar. Vented is designed for generating natural ventilation, with more than 5 square inches of vented area per lineal foot. We suggest that you read these instructions at least twice. and MAXITILE

Upload: others

Post on 30-Jun-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: LAP SIDING INSTALLATION GUIDE - cedarshinglesdirect.com › ... › 2015 › 04 › maxisoffit-installatio… · During installation or handling: (1) work in outdoor areas with ample

MaxiSOFFIT TM

to ASTM E-136, with zero me spread in accordance to ASTM E-184.

MaxiSOFFITTM

MaxiSOFFITTM

STORAGE AND HANDLING:

Protect from the weather. Use the plastic cover that is provided with the pallet to keep product dry. MaxiSOFFITTM is produced with a factory-applied primer; this primer does not provide adequate resistance to moisture in the event the product is allowed to become saturated during storage. If MaxiSOFFITTM becomes wet or saturated, allow product to dry before installation. Store product dry and �at prior to installation. Installing MaxiSOFFITTM wet or saturated may cause shrinkage at butt joint, which could produce breakage at corners. Protect edges and corners from chipping. Carry panels on edge.

MAXITILE is not responsible for damage caused by improper storage and / or handling of the product .

LAP SIDING INSTALLATION GUIDE

MaxiSOFFITTM

It will not rot or deteriorate. It is non-combustible in accordance

is available in ¼” (6 mm) nominal thickness intwo types: Vented (V) and Non-Vented (NV), in two textures,Smooth and Classic Cedar. Vented is designedfor generating natural ventilation, with more than 5 squareinches of vented area per lineal foot.

We suggest that you read these instructions at least twice.

and MAXITILE

Page 2: LAP SIDING INSTALLATION GUIDE - cedarshinglesdirect.com › ... › 2015 › 04 › maxisoffit-installatio… · During installation or handling: (1) work in outdoor areas with ample

ThicknessType

Non-Vented

Non-Vented

Vented or Non-Vented

Vented or Non-Vented

Vented or Non-Vented

¼”

(6 mm)

4’ (1.22 m)

Width Length Weight Packing

PACKAGING:

MaxiSOFFITTM is delivered in full pallets.

12” (0.30 m)

16” (0.41 m)

24” (0.61 m)

8’ (2.44 m)

10’ (3.05 m)

12’ (3.66 m)

8’ (2.44 m)

62.5 lb (28.4 kg)

78.1 lb (35.5 kg)

23.4 lb (10.6 kg)

31.3 lb (14.2 kg)

31.3 lb (14.2 kg)

60 pieces/pallet

50 pieces/pallet

240 pieces/pallet

180 pieces/pallet

120 pieces/pallet

CUTTING:

If power-sawing, use carbide- or diamond- tipped blade. Position cutting station so that wind will blow dust away from user and others in working area. Only use power cutting tools in well ventilated areas. Use NIOSH approved respirators and goggles for protection when power- sawing. For score-and-snap cutting, use a carbide-tipped scoring tool.

Snapper tools and shears can also be used. Round openings can be made by drilling several holes around circumference of the desired opening and tapping out the center. NEVER use a power saw indoors. NEVER dry sweep. Use wet suppression or HEPA vacuum.

Scoring Tool To scratch Score-and-Snap Round Openings

Circular SawCarbide or Diamond

Tip Blade

Always Use Protection

Wipper Snapper TM Snapper Shear TM

MAXITILE siding products contain respirable crystalline silica, which is known to the State of California to cause cancer and is considered by IARC and NIOSH to be a cause from some occupational sources. Breathing excessive amounts of respirable silica dust can also cause a disabling and potentially fatal lung disease called silicosis, and has been linked with other diseases. Some studies suggest smoking may in-crease these risks. During installation or handling: (1) work in outdoor areas with ample ventilation; (2) use ber-cement shears for cutting or, where not feasible, use a dust-reducing circular saw attached to a HEPA vacuum; (3) warn others in the immediate area; (4) wear a properly-

ted, NIOSH-approved dust mask or respirator (e.g. N-95) in accordance with applicable government regulations and manufacturer instruc -tions to further limit respirable silica exposures. During clean-up, use HEPA vacuums or wet methods, never dry sweep. For further informa-tion, refer to our installation guides and Material Safety Data Sheet available at www.maxitile.com or by calling (800) 451-2003 . FAILURE TO ADHERE TO OUR WARNINGS, MSDS, AND INSTALLATION GUIDES MAY CAUSE SERIOUS PERSONAL INJURY OR DEATH.

2 MaxiSOFFITTM | www.maxitile.com

Using a straight edge as a guide, carefully draw the scoring tool up and down several times. Bend upwards and break.

WARNING: AVOID BREATHING SILICA DUST.

Page 3: LAP SIDING INSTALLATION GUIDE - cedarshinglesdirect.com › ... › 2015 › 04 › maxisoffit-installatio… · During installation or handling: (1) work in outdoor areas with ample

FASTENERS:

Fasteners must be corrosion-resistant; preferably quality hot dipped galvanized nails. MAXITILE is not responsible for corrosion resistance of fasteners. Stainless steel fasteners are recommended when installing MAXITILE products near the ocean, or in very humid climates. Always check local building codes for additional requirements.

Screws shall be self-drilling all weather or stainless steel.

Staples are not allowed.

Installation into wood stud:

Nails must always hit studs, penetrating a min. of 1-inch into stud.

Nails can be applied using a smooth head hammer or a pneumatic

nail gun with �ush attachment so that nails are not over-driven.

If you are hand-nailing near corners, pre-drill the holes to avoid accidental breakage.

For wood frame construction, a minimum of 4d common nails x 1 ½” long spaced 8” O.C. (on center) at panel edges, and intermediate framing studs spaced up to 24” on center are suitable in most locations.

For conventional 20ga steel frame construction a minimum No. 8-18 x 0.323” HD x 1” long ribbed bugle screws spaced 6” o.c. at panel edges and intermediate framing members spaced up to 24” on center are suitable in most locations.

Drive fasteners perpendicular to siding and framing.

Do not over-drive nail heads or drive nails at an angle.

If nail is countersunk, caulk nail hole and add a nail.

Do not use aluminum fasteners, staples, or clipped head nails.

NOTE: Published wind loads may not be applicable to all areas where Local Building Codes have sp risdiction. Consult MAXITILE Technical Assistance if you are unsure of applicable compliance documentation.

Pneumatic Finishers Gun with Flush Attachment

Incorrect Correct

FRAMING:

MaxiSOFFITTM panels may be installed over either wood or steel framing complying with the Local Building Codes.

www.maxitile.com | MaxiSOFFITTM 3

Remember: Fastener always must be attached to structural framing members.

O.C.

Page 4: LAP SIDING INSTALLATION GUIDE - cedarshinglesdirect.com › ... › 2015 › 04 › maxisoffit-installatio… · During installation or handling: (1) work in outdoor areas with ample

INSTALLATION:

MaxiSOFFITTM panels must be fastened to a solid, nailable substrate such as wood 2x subfascia.

Additional framing may be needed to ensure proper fastening.

An insect screen can be installed using building adhesive, but the net ventilation will be reduced.

JOINTING METHODS:

Install MaxiSOFFITTM panels in moderate contact at ends or leave 1/8” gap and caulk.

Maintain a minimum 1” gap between gutter end caps and siding & trim.

KICKOUT FLASHING:

Because of the volume of water that can pour down a sloped roof, one of the most critical ashing details occurs where a roof intersects a sidewall.

The roo ashed with st ashing. Where the roof terminates, install a kickout of su cient length and in a direct angle that allows the water to run down the roof, away from the siding.

It is best to install a self-adhering membrane on the wall before the subfascia and trim boards are nailed in place, and then come back to install the kickout.

4 MaxiSOFFITTM | www.maxitile.com

Page 5: LAP SIDING INSTALLATION GUIDE - cedarshinglesdirect.com › ... › 2015 › 04 › maxisoffit-installatio… · During installation or handling: (1) work in outdoor areas with ample

FINISHING:

Patching: Repair chips and dents with acrylic patching mortar. Prime patched areas before coating.

Caulking: Use high quality, exterior grade, paintable elastomeric joint sealant, complying with ASTM-C 834 or ASTM-C 920 (grade NS, class 25) regulations. Caulking must be applied

according to manufacturer’s written instructions and ASTM-C 1193.

Painting:

MAXITILE will not warrant and does not assume any responsibility for the performance or appeara ld-applied primer and/or paint.

www.maxitile.com | MaxiSOFFITTM 5

Apply primer to repaired areas and then paint.

Before applying the �nish coat, clean all the �be r-cement products thoroughly. Use a high-quality 100% acrylic paint or primer. Always follow the paint manufacturer ’s instructions when painting.

If you desire stained �ber-cement product, use a high-quality 100% acrylic latex stain. Before staining,test a small amount of material in order to evaluate and ensure satisfaction. Always follow the manufacturer ’s instructions when staining.

All �ber-cement products must be painted once installed. You have up to 90 days (3 months) to apply a �nish coat on unprimed products and 180 days (6 months) on primed products. For best results with unprimed products, prime � rst and then �nish with exterior-grade topcoats. Two coats of paint must be applied on primed products.

Remember all exposed �eld cut edges should be covered with primer, sealant or paint. The caulk/sealant should be paintable or color matched, it should be compatible with MAXITILE siding and the material used for the trim.

Never apply primer or paint to wet or saturated �ber -cement products. Do not allow paint to freeze. Apply primer or paint when the air temperature is above 50°F (10°C).

MAXITILE does not recommend semi-transparent stain or paint because they can vary in uniformity ofappearance and they have not proven durable in exterior exposure and may require application of a refurbishing sealer at regular intervals.

MAXITILE siding, so� t and trim must be allowed to breathe. Some factory-applied primer or paint on the back is normal. Never completely prime or paint the back side, the product does not require this.

A small amount of material should be painted and evaluated to ensure satisfaction with the appearance before painting all material needed for job.

Never apply oil-based paints or stain to siding, so�t or trim. The use on unprimed or primed product could result in increase surface roughness, loss of adhesion, cracking or excessive chalk. Stains containing linseed oil are speci�cally designed for wood and not be suitable for �ber-cement products, primed or unprimed.

Page 6: LAP SIDING INSTALLATION GUIDE - cedarshinglesdirect.com › ... › 2015 › 04 › maxisoffit-installatio… · During installation or handling: (1) work in outdoor areas with ample

Thickness(inch)

FastenerSpacing

Stud Spacing(inches)

Height of Building

(feet)

Maximum basic wind speed(mph) for exposure category 1

B C

1/4”

4d box 1½ inch long

nails4

6 inches on center

2 by 4 wood5

15 204060

FastenerType

DIBC, IRC2 UBC 3

125120110105

1001008585

8585----

1051009085

80807070

7070----

16”

MAXIMUM WIND LOADS FOR MaxiSOFFITTM

1 N/A – not applicable2 Basic wind speed is the 3-second gust, miles per hour (km/hr), in accordance with IBC Section 1609.3 and IRC Section R301.2. 3 Basic wind speed is the fastest mile speed in accordance with UBC Section 1616.4 Nail has 0.09-inch -diameter shank and 0.218-inch-diameter head.

Frame Type

APPROVALS: In accordance with ICC-ES Legacy Report ESR-1381, MaxiSOFFITTM is compliant with the following codes: 2006 International Building Code (IBC) and 2006 International Residential Code (IRC) . MaxiSOFFITTM is also recognized for application in the following: City of Los Angeles Research Report No. 25252, State of Florida listing FL # 11009, U.S. Dept. of HUD Materials Release 1338, Texas Department of Insurance Product Evaluation EC-56,

and listing in Wildland Urban Interface Handbook (WUI). These documents should also be consulted for additional

Additional Installation Information, Warranties, and Warnings are available at www.maxitile.com.

MAXITILE, INC. 12950 Country Parkway, Suite 180. San Antonio, TX 78216. Ph: (800) 451-2003. Fax: (210) 545-7315 e-mail: [email protected]

www.maxitile.com Vers

ion:

S-M

SF-E

1-07

1910

6 MaxiSOFFITTM | www.maxitile.com

B C D

5 Wood speci�c gravity is 0.42 or higher.