lancair ivp systems...lancair ivp •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel...
TRANSCRIPT
![Page 1: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/1.jpg)
Lancair IVP Systems
![Page 2: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/2.jpg)
Lancair IVP
• General
– 4 place Experimental AB category
– +4.4 / -2.2 G’s utility
– NOT Aerobatic category
– GWT established by builder (3400# rec. by Lancair)
![Page 3: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/3.jpg)
Lancair IVP
• 98 square foot wing/ 108 w. winglets
• 80-110 gallons of fuel for IV/ IVP’s
• 5 PSID cabin pressurization
• Continental TSIO 550 (350 hp) engine
![Page 4: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/4.jpg)
Lancair IV Systems
![Page 5: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/5.jpg)
Lancair IVP Systems
• Engine
• Fuel
• Hydraulic
• Electrical
• Landing Gear
• Flaps
• Flight Controls
• Pressurization
![Page 6: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/6.jpg)
Lancair IVP Systems
• Engine
– TCMTSIO 550B, E or C
– 350 hp
– 6 cylinder
– Twin turbo charged
– 3 Intercoolers
![Page 7: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/7.jpg)
Lancair IVP Systems
• Fuel flow <45 gph at WOT
• >48 gph will flood engine on T/O
![Page 8: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/8.jpg)
Lancair IVP Systems
• Engine
– Cooling air is extremely important
– Max 400 degrees F CHT climb
– 380 degrees F cruise
– Affected by baffling
![Page 9: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/9.jpg)
Lancair IV Systems
![Page 10: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/10.jpg)
Lancair IVP Systems
• V8 applications
![Page 11: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/11.jpg)
Lancair IVP Systems
• Engine
– Bed Mount system
![Page 12: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/12.jpg)
Lancair IVP Systems
• Turbocharger
– Keep FOD free
– Cool down period not nec. (OWT)
– Support bracket check at 100 hr/ annual for cracks
– Oil lines check for leaks & chafing
![Page 13: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/13.jpg)
Lancair IVP Systems
• Engine/ Exhaust
– check oil air sep line at exhaust for coking at annual
![Page 14: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/14.jpg)
Lancair IVP Systems
• Engine Limits from TCM (except where noted)– 2700 RPM
– 38.5 inches MP (E ), 38.0 (B)
– 10 psi oil press (min)
– 30-60 psi oil press (normal)
– 240 deg F max oil temp.
– 100 deg F min oil temp for takeoff
– 160-200 deg F normal oil temp
– 380 max cruise CHT / 400 max climb CHT per GAMI
– 350 max continuous HP
![Page 15: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/15.jpg)
Lancair IVP Systems
• Fuel System– TCM Continuous flow (fuel
returns to tank selected)
– 80-110 gallons wet wings
– Gravity fed
– Duke electric boost
– Primer boost for start
– 2- 4 quick drains
– Fuel filter/ sump on firewall
![Page 16: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/16.jpg)
Lancair IVP Systems
• Fuel System
– Fuel filter/ sump on firewall
![Page 17: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/17.jpg)
Lancair IVP Systems
• Fuel System
– Fuel Selector Valve
– Left/ Right/ OFF
– Can leak internally or suck air
![Page 18: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/18.jpg)
Lancair IVP Systems
• Fuel System
– Dukes fuel pump
– Can fail internally
– Overboard line should be vented out
![Page 19: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/19.jpg)
Lancair IVP Systems
• Hydraulics– 1100 psi
– Oildyne (Parker) Electro-hydraulic res./ pump assy.
– Accumulator
– Operates flaps & gear
– Service system with Mil H 5606 fluid
![Page 20: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/20.jpg)
Lancair IVP Systems
• Hydraulics
– Controlled by hydraulic valve on panel
![Page 21: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/21.jpg)
Lancair IVP Systems
• Hydraulics
– Emergency hand pump
– Pumps down mains only
– Nose gear is pushed down by 110 psi gas strut
– Check operation in-flight annually
![Page 22: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/22.jpg)
Lancair IVP Systems
• Hydraulics
– Accumulator
– Check flap operation with pump off to determine if accumulator is airworthy
![Page 23: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/23.jpg)
Lancair IVP Systems
• Electrical
– Battery on firewall
– Electrical control panel
– Starter solenoid
– Battery solenoid
– CB panel
![Page 24: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/24.jpg)
Lancair IVP Systems
• Electrical
– Battery/ master switch
– #2 batt/ master
![Page 25: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/25.jpg)
Lancair IVP Systems
• Electrical
– 12 or 24 volt battery(s) on firewall or elsewhere
– 14v or 28 v system
– 60 -100 amp alternator
– Standby electrical system?
![Page 26: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/26.jpg)
Lancair IVP Systems
• CB Panel
![Page 27: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/27.jpg)
Lancair IVP Systems
• Main battery
![Page 28: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/28.jpg)
Lancair IVP Systems
• Standby battery
![Page 29: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/29.jpg)
Lancair IVP Systems
• Landing Gear– Mains hydraulically
actuated
– Internal downlock
– Held up by hyd pressure (no uplock)
– Rack and pinion operation
– Grease rack at annual/ 100 hour
– SB on nylaflow brake lines
![Page 30: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/30.jpg)
Lancair IVP Systems
• Landing Gear
– SB on nylaflow brake lines
![Page 31: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/31.jpg)
Lancair IVP Systems
• Cleveland wheels and brakes
• Gear door clearance is an issue
![Page 32: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/32.jpg)
Lancair IVP Systems
![Page 33: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/33.jpg)
Lancair IVP Systems
• Flight Controls
![Page 34: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/34.jpg)
Lancair IVP Systems
• Ailerons
– Counterweighted with lead on leading edge
– Travel +14/-20 degrees
![Page 35: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/35.jpg)
Lancair IVP Systems
• Rudder
– Mass balanced with lead counterweight
– Trim pocket
![Page 36: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/36.jpg)
Lancair IVP Systems
• Rudder
– Mass balanced with lead counterweight
– Trim pocket
![Page 37: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/37.jpg)
Lancair IVP Systems
• Flight Controls
– Elevator & aileron pushrods
– Rudder cables
– All pass through pressure vessel
![Page 38: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/38.jpg)
Lancair IVP Systems
• Flight Controls
– Rudder cables
![Page 39: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/39.jpg)
Lancair IVP Systems
• Flight Controls
– Full Slotted Fowler Flaps
– Vented
![Page 40: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/40.jpg)
Lancair IVP Systems
• Flight controls
– Flap actuator
– Hydraulically operated
– Flow control valve controls flap speed
![Page 41: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/41.jpg)
Lancair IVP Systems
• Flight Controls
– Elevator bell crank
![Page 42: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/42.jpg)
Lancair IVP Systems
• Flight Controls
– Compensator
![Page 43: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/43.jpg)
Lancair IVP Systems
• Compensator system with elevator boots
![Page 44: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/44.jpg)
Lancair IVP Systems
• Non compensator system
![Page 45: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/45.jpg)
Lancair IVP Systems
• Speed brake pocket
![Page 46: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/46.jpg)
Lancair IVP Systems
• Antenna
![Page 47: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/47.jpg)
Lancair IVP Systems
• Autopilot
– Servo locations
– brands
– malfunctions
![Page 48: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/48.jpg)
Lancair IVP Systems
• Autopilot servos
– Trutrak pitch and yaw servos
![Page 49: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/49.jpg)
Lancair IVP Systems
• Pressurization
– 5 psid
– Inflow valve• Mechanical via push
pull cables
• Dumps inflow
• Regulates temperature
![Page 50: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/50.jpg)
Lancair IVP Systems
• Pressurization– Dukes Controller
– Set +500’ for takeoff and landings
– Set for cruise altitude in flight
– Monitor cabin altitude in flight
– Can dump cabin quickly via door seal
![Page 51: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/51.jpg)
Lancair IVP Systems
• Pressurization
– Dukes outflow valve• Electrically operated
• Regulates Pressure
• Dumps cabin
• Located under rear seat
• Service annually per SB
![Page 52: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/52.jpg)
Lancair IVP Systems
• Pressurization
– Intercooler
– Conditions pressurized “bleed” air
![Page 53: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/53.jpg)
Lancair IVP Systems
• Panels / Instrumentation
![Page 54: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/54.jpg)
Lancair IVP Systems
• Panels/ Instrumentation
![Page 55: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/55.jpg)
Lancair IVP Systems
• Panels/ Instrumentation
![Page 56: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/56.jpg)
Lancair IVP Systems
• Panels/ Instrumentation
![Page 57: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/57.jpg)
Lancair IV Systems
• Air Conditioning
– Airflow Systems
![Page 58: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/58.jpg)
Lancair IVP Systems
• Air Conditioning
– Condenser
– Belly mounted or aft bay mounted
![Page 59: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/59.jpg)
Lancair IVP Systems
• Air Conditioning
– evaporator
![Page 60: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/60.jpg)
Lancair IVP Systems
• Air Conditioning
– Refrigerant lines
![Page 61: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/61.jpg)
Lancair IVP Systems
• Air Conditioning
– Compressor
– Engine mounted belt driven
– Or, aft bay mounted electrically driven
![Page 62: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/62.jpg)
Lancair IVP Systems
• Air conditioning
– Bracket failure
![Page 63: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/63.jpg)
Lancair IVP Systems
Lancair Systems Quiz• The hydraulic system operates the landing gear and flaps via:
– electric gear and flap switches on the control pedestal– hydraulic control valves on control pedestal for normal gear and flaps– mechanical levers that connect via push pull cables to the landing gear and flaps
• The fuel system on your aircraft has _____ gallons useable fuel.• You must use what type of hydraulic fluid to service the hydaraulic reservoir?
– Skydrol– Mil H 5606– Automatic transmission fluid
• The brake reservoir is located ____________ ?• The turbo charger has a TIT limit is?
– 1725 C– 1750F– 1650F
![Page 64: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/64.jpg)
Lancair IVP Systems
• Manifold pressure limit is – 38.5 inches– 38 inches– 29.5 inches
• How much supplemental O2 is required by 91.211?– 1 hour for each passenger– 10 minutes for each occupant– 30 minutes for the pilot – none
• The outflow valve is located _______________ and must be serviced how frequently?• Explain Lean of Peak operation • The nose gear strut is extended by—
– The hydraulic nose gear cylinder– The emergency gear down hand pump– The gas strut
![Page 65: Lancair IVP Systems...Lancair IVP •98 square foot wing/ 108 w. winglets •80-110 gallons of fuel for IV/ IVP’s •5 PSID cabin pressurization •Continental TSIO 550 (350 hp)](https://reader033.vdocuments.us/reader033/viewer/2022041811/5e57cd0fb8f995186d3cd716/html5/thumbnails/65.jpg)