lamp start-run-up-time-and-flicker-test
TRANSCRIPT
Lamp Start, Run-up time and Flicker Test
(LSRF-1)
Brochure
Global Office of Lisun Electronics Inc. http://www.Lisungroup.com
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon,
Hong Kong
Tel: 00852-68852050 Fax: 00852-30785638
Email: [email protected]
Lisun Electronics (Shanghai) Co., Ltd
Add: Room 1210, No. 9 Building, Jiangqiao Wanda Plaza, Hexuan Road, Jiading District,
Shanghai, 201803, China
Tel: +86(21)5108 3341 Fax: +86(21)5108 3342
Email: [email protected]
Lisun Electronics Inc. (USA)
Add: 445 S. Figueroa Street, Los Angeless, CA 90071, U.S.A.
Email: [email protected]
Lisun China Factory
Add: NO. 37, Xiangyuan Road, Hangzhou City, Zhejiang Province, China
Tel: +86-189-1799-6096
Email: [email protected]
Lead in CFL & LED Test Instruments
Lisun Electronics Inc. [email protected] www.Lisungroup.com
Dated 14th December, 2012, the EU officially released the (EU) NO 1194/2012 rules《Implementing
rules of the European Parliament and the EU Council Directive 2009/125/EC on the eco-design
requirements of directional lights, LED lights and related equipment requirements》.Compared with
《European Parliament and Council Directive 2005/32/EC implementing rules for non-directional
household lamps eco-design requirements》which posted by the European Commission Regulation
(EC) NO 244/2009 Regulations dated 18th March, 2009, the new rules have complete mandatory and
eco-design requirements. Start and Run-up time as the two indicators functional requirements in the
industry has been more emphasis by manufacturers.
To meet EU ErP requirements, IEC60969 Self-ballasted Lamps for General Lighting Services
Performance requirements and Energy Star about Lamp Start, Run-up Time and Flicker Test. LISUN
developed ErP test system, the system hardware consists of PH3000 and LSP-500VAC; the software
consists of LST-3000 Lamp Start and Run-up Time Test and FLK-3000 Lamp Flick Test.
1. Transit Photometer (PH3000) The Luminous flux, illuminance and Brightness are the most basic physical quantity in photometric
test. PH3000 Transit Photometer is developed base on rapid sampling techniques. It applied with 12
Bytes, the maximum sampling rate of 10M Hz high-speed A / D which can be achieved rapidly high
speed measurement of varying light photometric parameters. Combined with computer can record
the sampled waveform. The PH3000 also can used as normal illuminance meter, it can measuring
luminous flux, brightness, illuminance and photometric parameters.
Specification:
Photocurrent measurement range: 0.005x10-7~19999x10-8A; the measurement range of
luminous flux, brightness and illuminance depend on the sensitivity of acquisition and detector;
Users can achieve calibrate and zero through the instrument panel keyboard;
12 A / D conversion accuracy, five digital display;
Fourth gear range automatically converted tenfold;
USB and RS232 communicate ports;
Instrument level: Class 1.
Sampling rate: setting the fastest 20kS/s
Record: working with computer software, the record width can be set;
-Page 1 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
2. Programmable AC Power Source Meter (LSP-500VAC) LSP-500VAC Programmable AC Power Source combined with high power, low harmonic, high
stability pure sine wave and power meter functions. It’s suitable to power on electronic ballast, CFL
and low power household appliances. The LSP-500VAC has following characteristics:
Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform
feedback technology, low distortion power;
Applied with entire cycle high-precision measurement technology and high-speed sampling
technologies , panel of instrument will directly and accurately displays the power output of the
voltage, frequency, current, active power and power factor to achieve the integration of the
source table;
Applied with SCM control and measurement technology, high intelligence;
Applied with zero output impedance technology, the output equivalent impedance is almost zero
and further improve the stability of power supply;
Applied with isolated floating output technology, the power output and input have good isolation,
floating output, conducive to make sure power itself safety and operator's safety;
Perfect voltage, current anomalies and overheating protection, improve the reliability of power
supply;
Applied with power limiting technology to avoid strong interference on the power grid and other
electrical equipment, while facilitating reliable operation of the power supply itself;
The input voltage can be option via a toggle switch of panel mains 110V/220V;
The initial phase and end phase of the output voltage waveform can be set(0°-359°(±1°));
Measurement process can be programmed to control(1 to 50 memory groups, 1 to 9 steps for
each memory group);
Specification:
Input voltage: 110VAC or 220VAC±10% 50/60Hz;
Output frequency setting: 45.00-500.00Hz;
Output phase setting: 0°-359°(±1°);
Output voltage setting: AC 0.0-300.0V;
Maximum allowable output current: 0-150V(4.2A),0-300V(2.1A);
-Page 2 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
The total voltage distortion: ≤0.3%(No load or full load resistive load);
Voltage stability(≤0.1%/30 minute);
Equivalent resistance(≤0.1(Zero-resistance design);
Load Regulation: ≤0.1%;
Frequency stability: ≤0.05%/30 minute;
Meter display
Item Frequenc
y Voltage Current
Peak
Current Power Power Factor
Range 45-500Hz 0.1-300V 0.001-4.200A 0.0-5.9A 0.1-1200W 0.000-1.000
Resolution 0.1Hz 0.1V 0.001A 0.1A 0.1W 0.001
Accuracy ±0.05%re
ading
±(0.4%
reading)
±(0.4%
reading)
±(1%
reading)
±(0.4%
reading)
±(0.001%
reading)
3. New Design Integrating Sphere Due to the LED luminaries such as LED street luminaries developed, to do 4π geometry
testing, it is hard to be hold in the traditional integrating sphere design. To solve this
problem, Lisun design a new kind of sphere.
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40,
all tubes such as T5/T8/T12 and all kinds of luminaries
2. The hold base can be installed in the ceiling or down, it can be adjusted the height
3. Hold base has four power cables connect to the outside Power Supply and max is 5KW
Specification:
Diameter: 0.3m, 0.5m, 1.0m, 1.5m, 1.75m, 2.0m, 2.5m and 3.0m
The painting of integrating spheres is according to CIE Pub.No.84(1989)
-Page 3 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
BaSO4 coating: ρ(λ)≥0.96(450nm~800nm) and ρ(λ)≥0.92(380nm~450nm)
Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ(λ)<1.5%
Order Number:
Lisun Model 1.0m 1.5m 1.75m 2m
IS-1.0MA IS-1.5MA IS-1.75MA IS-2.0MA
Square side opening IS-1.0MA33P IS-1.5MA55P IS-1.75MA66P IS-2.0MA77P
Cycle side opening IS-1.0MA33C IS-1.5MA55C IS-1.75MA66C IS-2.0MA77C
Remark:
The 55P in IS-1.5MA55P means the side opening is 50x50cm square size
The 55C in IS-1.5MA55C means the side opening is diameter=50cm cycle size
4. Standard Lamp Source
OSRAM Standard Lamp to calibrate the
spectrum and luminous flux with Lisun Lab
certification. The data can be traced NIM. The
Standard Lamp Source is used to calibrate the
integrating sphere system. The different size of
Integrating Sphere should choose the right
power of standard lamp source
Integrating Sphere
Size
Standard Lamp
Source
0.3m/0.5m SLS-10W
1m/1.5m/1.75m SLS-50W
2m/2.5m/3m SLS-100W
5. Standard Instrument Cabinet 19Inch (Optional) Combine all of the test instruments in a 19 inch standard Cabinet, makes the whole
systems looks nice and is simple to use
-Page 4 -
Lisun Electronics Inc. [email protected] www.Lisungroup.com
6. Optical Fiber
1.5m length Connect the Spectroradiometer and integrating sphere
The next pages are the test report:
-Page 5 -