kyl-813 user manual

5

Click here to load reader

Upload: kyl03losia

Post on 14-Jan-2015

358 views

Category:

Education


2 download

DESCRIPTION

 

TRANSCRIPT

Page 1: KYL-813 user manual

ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd

Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com

KYL-81KYL-81KYL-81KYL-813333 wirelesswirelesswirelesswireless switchswitchswitchswitch inputinputinputinput andandandand outputoutputoutputoutputmodulemodulemodulemodule useruseruseruser manualmanualmanualmanual

ShenzhenShenzhenShenzhenShenzhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment Co.,Co.,Co.,Co., LtdLtdLtdLtd

Address:Address:Address:Address: Unit 5-7, Building3, Huangdu Square, South of Exhibition Center, YitianRoad, Futian District, Shenzhen Guangdong China

Tel:Tel:Tel:Tel: +0086-755-83410815Fax:Fax:Fax:Fax: +0086-755-83408785SkypeSkypeSkypeSkype:lxmlosiaYahooYahooYahooYahoo messenger:messenger:messenger:messenger: [email protected]:MSN:MSN:MSN: [email protected]_mail:E_mail:E_mail:E_mail: [email protected]/[email protected]:Website:Website:Website: http://www.rf-data.com

Page 2: KYL-813 user manual

ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd

Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com

KYL-813 wireless ON-OFF input and output module is a wireless

transmission equipment with four 2-channel DI and 2-channel relay DO.

I.I.I.I. FunctionFunctionFunctionFunction

2 channel ON-OFF DI and DO transmitting timely. The 2 channel

switching condition for the transmitting equipment can be output

timely at the receiver equipment. That is the switching condition for

the transmitting equipment is shut down, while the switching condition

will be shut down at the receiver equipment; and the transmitting

equipment is disconnect, while the receiver equipment will disconnect.

The following is the schematic diagram of the ON-OFF transmission.

Schematic diagram

IIIIIIII、Feature:Feature:Feature:Feature:

1、 2-channel coupler isolated inputs, high reliability and stability.

2、 2-channel relay dry contact output, contact current is 30V 1A.

3、 collocate wireless data transmission module with 2-3km.

Working frequency 433MHz(400-470MHz);

Page 3: KYL-813 user manual

ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd

Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com

RF power: 500mW;

Receive sensitivity: -123dBm

4、 Receive current: 30mA; transmitting current: 300mA

5、 Power supply: DC 12V

6、 Feature of the output contact as below follows: (the parameters

of the relay inside):

Page 4: KYL-813 user manual

ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd

Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com

IIIIIIIII.I.I.I. Exterior sketch map

VI.VI.VI.VI. ConnectionConnectionConnectionConnection DefinitionDefinitionDefinitionDefinition

Connection name Pin No. Definition RemarksCN11 VCC DC 12V (9-15V)2 GND Power supply3 GND4 INT15 GND6 INT27 OUT1A First channel relay output

A contactWhen the relay shutting,AandBconnected

8 OUT1B First channel relay outputB contact

9 OUT2A Second channel relayoutput A contact

When the relay shutting,AandBconnected

10 OUT2B Second channel relayoutput B contact

CN21 RXD Receiving data Enter the setting mode for the

module, and the function of theinterface will be effective

2 TXD Transmitting data

3 GND Ground of the signal

Page 5: KYL-813 user manual

ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd

Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com

4 GND Ground of the signal Programme controlling , lowlevel.Connect the signalground, then will enter theprogramme controlling mode

5 PRO SET Programme controlling

6 NCANT ANT Antenna port