kyl-813 user manual
DESCRIPTION
TRANSCRIPT
![Page 1: KYL-813 user manual](https://reader037.vdocuments.us/reader037/viewer/2022100414/54b5b4b44a7959097e8b45f7/html5/thumbnails/1.jpg)
ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd
Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com
KYL-81KYL-81KYL-81KYL-813333 wirelesswirelesswirelesswireless switchswitchswitchswitch inputinputinputinput andandandand outputoutputoutputoutputmodulemodulemodulemodule useruseruseruser manualmanualmanualmanual
ShenzhenShenzhenShenzhenShenzhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment Co.,Co.,Co.,Co., LtdLtdLtdLtd
Address:Address:Address:Address: Unit 5-7, Building3, Huangdu Square, South of Exhibition Center, YitianRoad, Futian District, Shenzhen Guangdong China
Tel:Tel:Tel:Tel: +0086-755-83410815Fax:Fax:Fax:Fax: +0086-755-83408785SkypeSkypeSkypeSkype:lxmlosiaYahooYahooYahooYahoo messenger:messenger:messenger:messenger: [email protected]:MSN:MSN:MSN: [email protected]_mail:E_mail:E_mail:E_mail: [email protected]/[email protected]:Website:Website:Website: http://www.rf-data.com
![Page 2: KYL-813 user manual](https://reader037.vdocuments.us/reader037/viewer/2022100414/54b5b4b44a7959097e8b45f7/html5/thumbnails/2.jpg)
ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd
Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com
KYL-813 wireless ON-OFF input and output module is a wireless
transmission equipment with four 2-channel DI and 2-channel relay DO.
I.I.I.I. FunctionFunctionFunctionFunction
2 channel ON-OFF DI and DO transmitting timely. The 2 channel
switching condition for the transmitting equipment can be output
timely at the receiver equipment. That is the switching condition for
the transmitting equipment is shut down, while the switching condition
will be shut down at the receiver equipment; and the transmitting
equipment is disconnect, while the receiver equipment will disconnect.
The following is the schematic diagram of the ON-OFF transmission.
Schematic diagram
IIIIIIII、Feature:Feature:Feature:Feature:
1、 2-channel coupler isolated inputs, high reliability and stability.
2、 2-channel relay dry contact output, contact current is 30V 1A.
3、 collocate wireless data transmission module with 2-3km.
Working frequency 433MHz(400-470MHz);
![Page 3: KYL-813 user manual](https://reader037.vdocuments.us/reader037/viewer/2022100414/54b5b4b44a7959097e8b45f7/html5/thumbnails/3.jpg)
ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd
Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com
RF power: 500mW;
Receive sensitivity: -123dBm
4、 Receive current: 30mA; transmitting current: 300mA
5、 Power supply: DC 12V
6、 Feature of the output contact as below follows: (the parameters
of the relay inside):
![Page 4: KYL-813 user manual](https://reader037.vdocuments.us/reader037/viewer/2022100414/54b5b4b44a7959097e8b45f7/html5/thumbnails/4.jpg)
ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd
Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com
IIIIIIIII.I.I.I. Exterior sketch map
VI.VI.VI.VI. ConnectionConnectionConnectionConnection DefinitionDefinitionDefinitionDefinition
Connection name Pin No. Definition RemarksCN11 VCC DC 12V (9-15V)2 GND Power supply3 GND4 INT15 GND6 INT27 OUT1A First channel relay output
A contactWhen the relay shutting,AandBconnected
8 OUT1B First channel relay outputB contact
9 OUT2A Second channel relayoutput A contact
When the relay shutting,AandBconnected
10 OUT2B Second channel relayoutput B contact
CN21 RXD Receiving data Enter the setting mode for the
module, and the function of theinterface will be effective
2 TXD Transmitting data
3 GND Ground of the signal
![Page 5: KYL-813 user manual](https://reader037.vdocuments.us/reader037/viewer/2022100414/54b5b4b44a7959097e8b45f7/html5/thumbnails/5.jpg)
ShenShenShenShenzzzzhenhenhenhen KYLKYLKYLKYL CommunicationCommunicationCommunicationCommunication EquipmentEquipmentEquipmentEquipment CoCoCoCo....,,,, LtdLtdLtdLtd
Fax:Fax:Fax:Fax: +0086+0086+0086+0086----755755755755-83408785-83408785-83408785-83408785 [email protected]@[email protected]@gmail.com www.rf-data.comwww.rf-data.comwww.rf-data.comwww.rf-data.com
4 GND Ground of the signal Programme controlling , lowlevel.Connect the signalground, then will enter theprogramme controlling mode
5 PRO SET Programme controlling
6 NCANT ANT Antenna port