kone design collection monospace500€¦ · compliant with en81-20/50 lift standards kone design...

23
CompliantwithEN81-20/50LiftStandards KONE DESIGN COLLECTION MonoSpace ® 500

Upload: vanhanh

Post on 17-Apr-2018

221 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

Compliant with EN81-20/50 Lift Standards

KONE DESIGN COLLECTION

MonoSpace®500

Page 2: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

EN81-20 & EN81-50 Lift StandardsOn 1 September 2017, implementation of the two newly published EN81-20:2014 and EN81-50:2014 standards

for lift design and manufacturing will bring considerable benefits in terms of accessibility and safety for both

passengers and service engineers on all lift handovers. All lift handovers with a Declaration of Conformity signed

and dated on/after the 1 September 2017 must be compliant to the standards.

Safety requirements for passengers

Requirements related to Unintended Car Movement (UCM) and ascending car overspeed

The requirements for the protection mechanism that address the risk of the car moving away from the landing have been enhanced. KONE already has lift solutions available that include standard features to address unintended car movement and KONE lifts also include standard features that address the risk of uncontrolled speed when the car is ascending.

Safety requirements for service engineers

Car roof balustrades

Balustrades located on the lift car roof now have defined strength requirements and updated height requirements. to reduce the risk of engineers falling into the shaft while working on the car roof. The new requirements are as follows:

• Where the distance between the inner edge of the balustrade handrail and the shaft wall is up to 500 mm, the balustrade must have a minimum height of 700 mm.

• Where the distance between the inner edge of the balustrade handrail and the shaft wall exceeds 500 mm the balustrade must have a minimum height of 1100 mm.

Changes affecting building design

The EN 81-20:2014 and EN 81-50:2014 standard introduces some changes to the requirements that the building designer is required to fulfill. These changes all apply to the lift shaft, and are as follows:

• Potential shaft size changes• All glass used in the lift shaft must be laminated.• Shaft walls to withstand 1000N• Calculations for shaft ventilation• Protection of ledges greater than 150mm

More information

For full details of the new standards, customers should refer to the official EN 81-20:2014 and EN 81-50:2014 standards documents. Please contact your local KONE representative for more information.

2

Page 3: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

3To create your own unique lift car using the KONE Car Designer tool, visit www.KONE.co.uk

Selectable car elements

Handrail

Ceiling

Skirting

Side wall

Mirror

Rear wall

Floor

Seat

Tenant directory

Digital info screenCar operating panel (COP)

KONE’s new, award-winning horizontal wall panel design is visually appealing and creates a spacious feeling inside the lift car.

Key

A

B

C

D

E

F

G

H

Blue

Green

Light BlueOrange

Dark Grey

Black

Pink

Light Grey

Price Group F

Price Group E

Price Group C

Price Group B

Price Group A

Price Group D

Price Group G

Price Group H

To create your own unique lift car using the KONE Car Designer tool, visit www.KONE.co.uk

I Yellow Price Group I

Page 4: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

4

Vertical2-panels per wall

Horizontal4-panels per wall

Wall Finishes

Asturias SatinF (441)F (304)F (316)

SS1Shangri-La Gold

SS2Vegas Gold

SS3Paris Black

HMurano Mirror

P50Cloud White

TS1Flemish Linen

SS4Aqua Weave

SS5Golden Linen

SS6Sunlit Twill

P52Sunny Yellow

KScottish Quad

P51Misty Grey

P53Dawn Red

P54Sky Blue

Painted steel

Brushed stainless steel Mirror polished stainless steel

Textured stainless steel

Etched stainless steel

ES1Silver Diamond

ES2Silver Bamboo

ES3Silver High-Rise

ES4Golden Bamboo

Wall panel configuration

• All materials are available with vertical 2-panel per wall and horizontal 4-panel per wall designs for KONE MonoSpace® 500

• Material scaling & variability

• Patterned images not to scale. Consult your sales representative for Car Designer Tool and samples.

• Real wood laminates are made of natural materials so variation will occur.

A

BF D F F

C F F

GG GG

A A A A

C C

1 2

CD

Page 5: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

5

Wall Finishes

L217Windwall Orange

R30Nordic Grey

Printed laminate

3D laminate

Laminate

Metallic laminateCoated steelSteel

ZZinc coated, local paint or decoration

L210Graphic Bamboo

L211Chennai Lights

L212Colour Cool

L213Shanghai Lights

L202Hazel Oak

L206Mandarin Orange

L203Almond Oak

L207Lime Green

L204Cherry Oak

L208Lotus Blue

L205Ebony Oak

L209Snowberry White

L200Oriental Gold

L201*Oriental Bronze

L214Aqua Blue

L215Aqua Black

L216Windwall White

Real wood laminate

L219Oak

L220Walnut

L221Wenge

L222Black Oak

L223Wild Wenge

A F F

EEEEE

Printed laminate wall finishes can be applied either on the back wall or side walls.

* Due to the special characteristics of this material, the appearance of brush marks may vary between wall panels. Alignment of these markings cannot be guaranteed.

B

D D D D

DDD D

DD D D

F FFF

Page 6: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

6

Brushed stainless steel

HMurano Mirror

Mirror polished stainless steel

SS1Shangri-La Gold

SS2Vegas Gold

SS3Paris Black

P50Cloud White

P51Misty Grey

R30Nordic Grey

Coated steel

Textured stainless steel

Steel

TS1Flemish Linen

KScottish Quad

ZRaw surface

SS4Aqua Weave

Painted steel

Front Wall Finishes

C

A

FD

BR1Light Wood (WL)

BR1Lava Black (RC26)

BR1Flemish Linen (TS)

FAsturias Satin

SS1Shangri-La Gold

Buffer Rails

Skirting

BR1Dark Wood (WD)

DB

AAA

CC

F

CB C

EAsturias SatinF (441)F (304)F (316)

BCD

C

Page 7: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

7

Vinyl

Stone

Metal plate

RC6Dallas Black

RC20Smoke Grey

VF20Ash Grey

SF30Chalk White *

VF21Sepia Brown

SF31Grainy Sand *

ALAluminium *

VF22Carbon Grey

SF32Diorite Black *

ZRaw surface

VF23Steel Grey

VF24Jute Brown

RC21Denver Grey

RC22Shell Grey

RC23Coral Red

RC24Dusk Blue

RC25Twilight Black

Rubber

Local floor

Floor Finishes

A

B

AAA

AA

A

B B B B

CCC

C

* Vandal resistant EN81-71

Recessed for finish by othersMax 23mm

VF25Flaky Grey

B

SF36Spring Sand

D

Page 8: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

8

Clear Glass

Patterned glass

Coloured glass

TW1 * Glass

GW1Siberian Glaze

GW10Jaipur Glaze

GW4Manhattan Glaze

GW11Soho Glaze

G5Silver Flow

G6White Diamond

G11Classic Bamboo

G7Silver Chain

G12*London Lights

G9Night High-Rise

Glass is only available to the rear wall as a single piece.

* Note These patterned glasses are transparent.

Rear Wall Glass Finishes

I

II I I

II I I

I I

Page 9: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

9

Ceilings

Type: CL98Finish: Asturias Satin (F)

Murano Mirror (H)Lighting: LED spot lights, rectangular

Type: CL95Frame finish: Asturias Satin (F)

Murano Mirror (H)

Centre panels: Cloud White (P50) painted steelLighting: T5 fluorescent tubes

Type: CL97Finishes: Asturias Satin (F)

Murano Mirror (H)

Shangri-La Gold (SS1) Lighting: LED spot lights, square

Type: RL12 Integrated ceiling Finishes: Cloud White (P50)

Misty Grey (P51)

Lighting: LED spot lights, round

Type: CL151Frame finishes: Asturias Satin (F)

Shangri-La Gold (SS1)

Lighting: LED panel with frosted white diffuser, plain or with graphics.

Page 10: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

10

3Bamboo

1Geometric

2High-Rise

Graphic options for frosted white diffuser panel

Ceilings

Type: CL104Frame finish: Asturias Satin (F)

Murano Mirror (H)

Centre panels: Cloud White (P50) painted steelLighting: T5 fluorescent tubes

Type: CL193Frame finish: Asturias Satin (F)

Centre panels: Cloud White (P50) painted steel

Lighting: T5 fluorescent tubes

Not available with a mirror on car wall

Type: CL181Finishes: Asturias Satin (F)

Murano Mirror (H)

Shangri-La Gold (SS1) Vegas (SS2) Lighting: LED

Type: CL162Finishes: Asturias Satin (F)

Murano Mirror (H)

Top panel: Cloud White (P50) painted steel Lighting: T5 Fluorescent tubes and LED spot lights, square

Page 11: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

11

HR64*Round, bent endsFinishes: Asturias Satin (F) Murano Mirror (H) Shangri-La Gold (SS1) Vandal resistant

HR65*Triangular, bent endsFinishes: Asturias Satin (F) Murano Mirror (H)

HR71RoundLight Wood with Asturias Satin fixings (WLF)Golden brushed stainless steel fixings also available

HR34Round, bent ends Aluminium (LBE) with black end caps

HR81Round, sidewall and floor mounted Finishes: Asturias Satin (F) Murano Mirror (H) Shangri-La Gold (SS1)

Handrails

Mirrors

MR1Full width/Partial height *

MR1Full width/Full height *

SIZES AND POSITIONING

MR1Partial width/Partial height

MR1Partial width/Mid height

Mirrors can be located on the rear and side walls of the lift car. Mirror and handrail dimensions are determined by the wall width. Please consult your KONE sales representative for details.

Page 12: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

12

Stainless steel Textured stainless steel

Etched stainless steel

Coated steel Painted steel

TS1Flemish Linen

KScottish Quad

ES2 Silver Bamboo

ZRaw surface

FAsturias Satin

P55Thunder Grey Landing door only

HMurano Mirror

SS1Shangri-La Gold

SS4Aqua Weave

ES5Brushed Bamboo

ES3 Silver High-rise

R30Nordic Grey

Narrow frame Frame

P50Cloud White

P51Misty Grey

Steel

Landing door types

PPainted steel

Note:Finish availability varies according to door type. Consult your sales representative for more information.

Car/Landing Door Finishes & Maintenance Access Panel

• Maintenance and rescue operations are integrated in a small cabinet

• Integrated at topmost landing door or one floor below

• Wall MAP available also recessed and/or placed on side wall

MAP integrated intodoor frame

Maintenance Access Panel

Wall-mounted MAPWall- mounted MAP

TW1 Transparent

Glass Patterned transparent glass

G14 White Bamboo

G12London Lights

Front Narrow frame door with glass panels

Page 13: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

13

KSS 470

Surface mounted signalisation

KSI 471

KSH 470

Landing devices

KSL 470

Car operating panel (COP)

KSC 471Full height

Faceplate finishes: Asturias Satin (F)

Displays: KSC 471: Dot matrix

Available with vertical paneling only

KSS 280

Surface mounted signalisation

Landing devices

Car operating panel (COP)

KSC 2963/4 height

Faceplate finishes: Black polycarbonate and deep formed Asturias Satin (F) vertical hairline

Displays: Segmented LCD

KSL 284

KSH 280 KSI 286

KSL 280

KONE Signalisation

KSC 286Partial height

Page 14: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

14

KSS 570

Surface mounted signalisation

Landing devices

KSL 570

KSA 573

KSI 573

KSH 570

KSC 573/575Full height

Faceplate finishes: Asturias Satin (F)Murano Mirror (H) Golden Mirror (HTIN) Displays: KSC 573: Scrolling dot matrixKSC 575: Black and white LCD

Car operating panel (COP)

Available with vertical paneling only

KSS 140

Flush mounted, vandal resistant

signalisation Available with vertical paneling only

Landing devices

KSL 140

KSI 143

KSH 140

Car operating panel (COP)

KSC 140 Full height

Faceplate finishes: Scottish Quad (K) orAsturias Satin (F) Displays: Scrolling dot matrix

KONE Signalisation

Page 15: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

15

KSS 670

Flush mounted signalisation

Landing devices

KSL 670

KSA 673

KSI 673/675

KSC 673/675Full height

Faceplate finishes: Asturias Satin (F)Murano Mirror (H)Golden Mirror (HTIN)M M M Displays: KSC 673: Scrolling dot matrixKSC 675: Black and white LCD

Car operating panel (COP)

KONE SignalisationKSS 800

Surface mounted signalisation

KSP853 Destination operating panel (DOP)

Lift identifier (EID)

Faceplate finishes: Black polycarbonate Displays: KSC 863: Scrolling dot matrix

Car operating panel (COP)

KSC 863Full height

KST 860 Active

KST 850 Passive

KSP 853

Touchscreen destination operating panel (DOP)

Landing devices

KSP 858

Page 16: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

16 Selection of 8 solid colours is available for landing devices.

KSC D40

Full height Car operating panel (COP)

KSC D20

Partial height Car operating panel (COP)

Landing devices (KSC D20, KSC D40, Unique/ Numbers and Blocks)

Unique designs

Blocks Zoo Numbers

Note:Custom designs are also available. Contact your KONE sales representative for more information.

KSL D20KSL D40

KSI D42

KSI D41

KSH D20

Width 233 mm, height depends on car height and selected ceiling option

Width 200 mm, height 1300 mm

Same faceplate designs available as in Partial height KSC D20.

KONE Design signalisation

Page 17: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

17

KONE MonoSpace 500 minimum headroom height (SH) according to ceiling type

Speed(m/s)

Standard ceiling(mm)

RL12 CL88L *CL94L *CL162

CL193

1.0 CH + 1300 or 1700 CH + 1220 or 1620 CH + 1380 or 1780 CH + 1330 or 1730

1.6 CH + 1500 or 1900 CH + 1420 or 1820 CH + 1580 or 1980 CH + 1530 or 1930

1.75 CH + 1500 or 1900 CH + 1420 0r 1820 CH + 1580 or 1980 CH + 1530 or 1930

Frame widths: Frame door: (WW – LL – FW1 – FW) / 2 = 120 mm

Narrow frame: (WW – LL – FW1 – FW) / 2 = 50 mm

BB

DD

WD

Through type carCenter opening

WW

LL

LL

FW1 FW

BB

DD

WD

Through type car

Front Type CarsFrame Type Cars

Center openingWW

LL

LL

LW1 LW

BB

DD

WD

Single entrance carCenter opening

WW

LLFW1 FW

BB

DD

WD

Single entrance carCenter opening

WW

LLLW1 LW

BB

DD

WD

WW

Through type carSide opening

LL

LLFWFW1

BB

DD

WD

WW

Single entrance carSide opening

LLFWFW1

BB

DD

WD

WW

Single entrance carSide opening

LLLWLW1

BB

DD

WD

WW

Through type carSide opening

LL

LLLWLW1

Hea

droo

m h

eigh

t (S

H)

Trav

elPi

t he

ight

(PH

)

Car

Hei

ght

(CH

)

BB

DD

WD

Through type carCenter opening

WW

LL

LL

FW1 FW

BB

DD

WD

Through type car

Front Type CarsFrame Type Cars

Center openingWW

LL

LL

LW1 LW

BB

DD

WD

Single entrance carCenter opening

WW

LLFW1 FW

BB

DD

WD

Single entrance carCenter opening

WW

LLLW1 LW

BB

DD

WD

WW

Through type carSide opening

LL

LLFWFW1

BB

DD

WD

WW

Single entrance carSide opening

LLFWFW1

BB

DD

WDWW

Single entrance carSide opening

LLLWLW1

BB

DD

WD

WW

Through type carSide opening

LL

LLLWLW1

Hea

droo

m h

eigh

t (S

H)

Trav

elPi

t he

ight

(PH

)

Car

Hei

ght

(CH

)

BB

DD

WD

Through type carCenter opening

WW

LL

LL

FW1 FW

BB

DD

WD

Through type car

Front Type CarsFrame Type Cars

Center openingWW

LL

LL

LW1 LW

BB

DD

WD

Single entrance carCenter opening

WW

LLFW1 FW

BB

DD

WD

Single entrance carCenter opening

WW

LLLW1 LW

BB

DD

WD

WW

Through type carSide opening

LL

LLFWFW1

BB

DD

WD

WW

Single entrance carSide opening

LLFWFW1

BB

DD

WD

WW

Single entrance carSide opening

LLLWLW1

BB

DD

WD

WW

Through type carSide opening

LL

LLLWLW1

Hea

droo

m h

eigh

t (S

H)

Trav

elPi

t he

ight

(PH

)

Car

Hei

ght

(CH

)

BB

DD

WD

Through type carCenter opening

WW

LL

LL

FW1 FW

BB

DD

WD

Through type car

Front Type CarsFrame Type Cars

Center openingWW

LL

LL

LW1 LW

BB

DD

WD

Single entrance carCenter opening

WW

LLFW1 FW

BBD

D

WD

Single entrance carCenter opening

WW

LLLW1 LW

BB

DD

WD

WW

Through type carSide opening

LL

LLFWFW1

BB

DD

WD

WW

Single entrance carSide opening

LLFWFW1

BB

DD

WD

WW

Single entrance carSide opening

LLLWLW1

BB

DD

WD

WW

Through type carSide opening

LL

LLLWLW1

Hea

droo

m h

eigh

t (S

H)

Trav

elPi

t he

ight

(PH

)

Car

Hei

ght

(CH

)

Single entrance car (SEC)

Through type car (TTC)

Side opening

Side opening

Centre opening

Centre opening

Frame and narrow frame door types

Hea

droo

m h

eigh

t (S

H)

Trav

elPi

t hei

ght (

PH)

Car

Hei

ght

(CH

)

Pit

heig

ht (

PH)

(H

R)

(H

H)

Hea

droo

m h

eigh

t (S

H)

Trav

elPi

t hei

ght (

PH)

Car

Hei

ght

(CH

)

Pit

heig

ht (

PH)

(H

R)

(H

H)

Q = Rated load of liftBB = Car widthDD = Car depthCH = Car clear heightFW1 = Side wall left - frame door application onlyHH = Door clear opening height HR = Door raw opening heightLL = Door clear opening widthWW = Shaft widthWD = Shaft depth

* These ceilings are applicable to fire fighting lifts BS EN81-72 To ensure that your ceiling height complies with EN81-20/50, please consult your KONE representative

KONE MonoSpace 500 duty range

Speed(m/s)

Load (kg)

Travel(m)

Stops

1 320 -1150 55 21

1.6 400 - 1150 75 24

1.7 5 400 - 1150 75 24

KONE MonoSpace 500 pit depth (PH)

Speed (m/s)

Standard With counter-weight safety gear

1.0 1050 1400

1.6 1200 1400

1.75 1200 N/A

Max 1550

KONE MonoSpace® 500 Planning Guide

Page 18: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

800/9001900/1950

1400

1400

1750/1950

9001750/1950

2100

2400

(251

0)

1100

1700 1350

1800

800/900

1100

800/9001950

15001400

1850

1850

1950/2350

1400

2150

900/1100

1400

2150/2350

1600

1900

900/1100

(226

0)

800/9001470/1600

12501000

1625

(191

0)

800/9001570/1600

2100

2475

(271

0)1100

800/900/1000

15001400

1875

(211

0)

1900

18501400

2225

800/900/1000

1900

800/9001570/1600

14001100

1775

(201

0)

6/480kg 8/630kg

15/1150kg

12/900kg 13/1000kg

8/630kg 10/800kg 12/900kg

15/1150kg13/1000kg

13/1000kg

For options not shown, including loads, car sizes, entrance sizes and speeds, please contact your local KONE representative. BS EN 81-21 (existing building)BS EN81-70 (accessibility)BS EN81-72 (fire fighting)BS EN81-71 Category 1 (vandal resistant)BS EN81-73 (fire behaviour)BS 9999 Annex G (evacuation control)

Side opening doors

Centre opening doors

18

KONE MonoSpace® 500 Planning Guide

Page 19: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

19

Options

IS08 Standard version, 8.4” display Surface mounted

IS15 Premium version, 15” display Surface mounted

Digital info screens

Card readers

Card reader Card reader with PIN

Our user-friendly, integrated access and destination solutions are designed to make it easy for people to move throughout your building.

Wireless 3G GSM

KONE’s wireless 3G GSM unit is a cost effective solution for single units and goes hand-in-hand with KONE Remote Monitoring (KRM) system.

Easy installation and configuration by KONE with no extra lead time or phone line operator required.

Access cards for end users

Recommended options to enhance lift performance and passenger experience

Residential Retail Office Hotel Leisure & Education

Advanced door opening (ADO) a a a

Quick close on call (QCC) a a a

Parking at main/pre-defined floor

(PAM/PAD)a a a a

Out of service switch in car (OSS

COI)a a a

BMS elevator link (LIL) a a a a a

Bypass load function (BLF) a a a

Extended door opening (DOE B) a a

Automatic switch-off (SBM) a a a a a

More suggestions

Page 20: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

20

Easy selection of car interiors. From a collection of functional and visually appealing designs created by KONE’s award-winning design professionals.

The most flexible and versatile offering. The KONE Design Collection includes 52 stylish car interiors. We also offer 100 different materials and accessories that can be combined freely and used in all lift products, for both new buildings and modernisation projects.

The most innovative materials. The combination of unique textured, patterned and 3D-effect wall materials with novel lighting solutions creates a stunning visual effect.

Award-winning design. KONE’s lift and signalisation design concepts have received both Red Dot and Good Design awards.

What sets KONE design apart

3

4

21 Think about your building design:

• What kind of overall look are you aiming to achieve? Modern or more traditional? Bold and bright, or subtle and minimalist?

• What kind of ambiance are you looking for? Cool and light or warm and cosy?

• Is your detailing simple or more rich?

• What materials and colours does the building include?

Get inspiration from our six design themes, browse through our car designs and find the one that best matches your building interior.

For a truly unique look, try our Car Designer tool, where you can mix and match materials and accessories to create a virtual experience of your very own lift car design.

Talk to a KONE expert, who will be able to give you professional advice on what design might best fit your building.

32

1

Choosing the right design

4

GOOD DESIGN ADDS REAL VALUE

A well-designed lift can have a huge impact on the way people feel about your building and connect with it. From residential buildings and hotels to retail and office environments, the ability to give people a comfortable ride in a pleasant, accessible environment speaks volume about your building and your values.

• A well-designed lift has a positive impact on everyday living in residential buildings. It should combine sophisticated design details with practical, functional features.

• In hotels and retail environments, combining inspiring design with reliable operation and excellent usability creates a positive lasting impression for guests and visitors alike.

• In commercial spaces such as offices, a visually impressive lift that also delivers great performance is a compelling factor for both potential and existing tenants.

CUTTING-EDGE DESIGN BASED ON IN-DEPTH RESEARCH

This collection is the result of years of expert design research. Drawing on continuous studies of the latest trends in architecture, design and material technology, our team of design professionals has created a diverse set of themes that appeal to a wide variety of tastes and are flexible for use in a range of different environments. The unique patterns and material finishes we offer have been created especially for KONE in close collaboration with our R&D team and our partners.

Award winning designPatterns that catch the eye. Finishes that enhance the look and feel of your building. Lighting that adds mood and atmosphere. Material combinations that inspire and delight. Add emotion to your lift with the KONE Design collection.

4 Red Dot design awards2 Good Design awards

Page 21: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

21

Top-class energy efficiency

2 Eco-efficient regenerative drive

Our latest regenerative drive recycles energy for immediate reuse within the building and cuts consumption by up to 20%.

3 Long-lasting LED lighting

As well as being 80% more efficient than halogen lighting, LED lighting also lasts 10 times longer.

4 More advanced standby solutions

Upgraded standby solutions power down the equipment when it is not in use, providing substantial energy savings.

More efficient hoisting machinery

The completely renewed KONE EcoDisc® hoisting motor and highly efficient drive system delivers even better energy efficiency, helping to reduce both operating costs and your building’s carbon footprint.

1SAVE ENERGY, SAVE SPACE

As well as offering world-class energy efficiency, because the renewed KONE MonoSpace® is now even more compact it also helps you save valuable space.

• The highly compact lift equipment – including the KONE EcoDisc hoisting machine and other mechanical structures – now requires even less height and width in the shaft.

• This frees up valuable floor space or allows for a more spacious, higher-capacity car.

• When replacing an existing lift, the new KONE MonoSpace eliminates the need for a machine room and maximises lift capacity within the existing shaft dimensions.

CONTRIBUTING TO SUSTAINABLE URBANISATION

KONE, an innovative leader in the lift and escalator

industry, is the first company to annouce the A-class

energy effciency classification according to ISO 25745-2

for its customer reference cases.

Published in March 2015, ISO 25745 is the global

standard for the energy calculation and classification

of lifts and escalators. The A-class rating is the best one

that can be given to lifts under the new standard. A+++

is the best rating that escalators can receive.

KONE has a long history in makings its lifts more energy

efficient, This has been achieved by using innovative

and eco-efficient technologies such as regenerative

drives, standby solutions and LED lighting that

drastically reduces the energy consumption of the lift.

By installing a eco-efficient KONE lift solution, you can

help achieve a green bulding accreditation such as

LEED and BREEAM for your building design.

KONE MonoSpace® 500Lift Type Traction

Operating days / year 365

Usage category 2

Date of evaluations Nov 20, 2014

Load kg 630

Speed m/s 1.0

Energy efficiency class A

KONE EcoSpace®

Lift Type Traction

Operating days / year 365

Usage category 1

Date of evaluations Dec 16, 2014

Load kg 630

Speed m/s 0.63

Energy efficiency class A

KONE MiniSpace®

Lift Type Traction

Operating days / year 365

Usage category 4

Date of evaluations Nov 18, 2014

Load kg 1,200

Speed m/s 4.0

Energy efficiency class A

Page 22: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

22

Industry-leading ride comfortFOR THE BEST POSSIBLE PASSENGER EXPERIENCE

ALL LIFTS TESTED FOR RIDE COMFORT – A SERVICE UNIQUE TO KONE

• KONE provides a comprehensive ride comfort testing service as standard for all its lift installations.

• Your lift will not be handed over for use before it passes this test, which measures noise and vibration levels inside the car.

• This thorough quality and reliability testing prior to handover further reduces the need for unplanned maintenance callouts.

Every aspect of the upgraded KONE MonoSpace® is designed to add real value to your

building and maximise comfort, safety and convenience for passengers. The renewed

KONE EcoDisc® hoisting machine is complemented by a wide range of other upgrades

that are designed to deliver industry-leading ride comfort year after year.

32 Redesigned hoisting system for minimised vibration and noise

• Centralised, low-friction hoisting cuts noise and vibration, improving comfort for passengers and minimising disturbance to the surrounding areas.

1 Renewed machinery and brakes

• The new, highly reliable motor control system further improves ride comfort, with smooth acceleration and deceleration and highly accurate car leveling.

• The renewed braking system ensures a comfortable, safe, quiet ride, while also minimising noise transfer to the surrounding areas.

• The new brake test functionality automatically checks brake condition daily. This helps to further improve safety and reliability.

Improved car structure for a more comfortable ride

• The rigid structure and noise isolation of the renewed lift car ensure a smooth and comfortable ride.

• New isolated guide shoes, constructed using low-noise sliding material, further help to reduce noise.

Page 23: KONE DESIGN COLLECTION MonoSpace500€¦ · Compliant with EN81-20/50 Lift Standards KONE DESIGN COLLECTION MonoSpace ®500

This publication is for general informational purposes only and we reserve the right at any time to alter the product design and specifications. No statement contained in this publication shall be construed as a warranty or condition, expressed or implied, as to any product, its fitness for any particular purpose, merchantability, quality or shall be interpreted as a term or condition of any purchase agreement for the products or services contained in this publication. Minor differences between printed and actual colors may exist. KONE®, Dedicated to People Flow™, KONE MonoSpace®, KONE MiniSpace™ KONE EcoDisc®, KONE MaxiSpace™, KONE InnoTrack™ are trademarks or registered trademarks of KONE Corporation. Copyright © 2015 KONE Corporation. Data correct at time of print.

8001/JAN 2018

KONE provides innovative and eco-efficient

solutions for lifts, escalators, automatic

building doors and the systems that integrate

them with today’s intelligent buildings.

We support our customers every step of

the way; from design manufacturing and

installation to maintenance and modernisation.

KONE is a global leader in helping our

customers manage the smooth flow of people

and goods throughout their buildings.

Our commitment to customers is present in

all KONE solutions. This makes us a reliable

partner throughout the lifecycle of the

building. We challenge the conventional

wisdom of the industry. We are fast, flexible,

and we have a well-deserved reputation as a

technology leader, with such innovations as

KONE MonoSpace®, KONE NanoSpaceTM and

KONE UltraRope™.

KONE employs close to 52,000 dedicated

experts to serve you globally and locally.

KeyHead OfficeOfficesBranches

KONE PLC

Head officeGlobal House, Station PlaceChertsey, SurreyKT16 9HW

General EnquiriesTel: 0845 1 999 999

www.kone.co.uk

Regional Offices50 Bedford RoadLondonSW4 7HJ

Worth Bridge RoadKeighley, West YorkshireBD21 4YA

2425 Regents Court, The Crescent,Birmingham Business Park, Solihull, West MidlandsB37 7YE

Suites 3-5 Corum One,Corum Office Park, Crown Way,Warmley (Bristol), GloucestershireBS30 8FJ