ko-mag instruction manual _vacuum laminating machine

113
Tsunami ® 8000 Series (Point-to-point and Point-to-multipoint Products) Hardware Installation Guide Products Covered --> Tsunami™ Multipoint - MP-8100-BSU - MP-8200-BSU; MP-8250-BS9; MP-8250-BS1 - MP-8100-SUA - MP-8150-SUR - MP-8150-SUR-100 - MP-8150-CPE - MP-8200-SUA - MP-8250-SUR - MP-8160-BSU and MP-8160-BS9 - MP-8160-SUA - MP-8160-CPE --> Tsunami QuickBridge ® - QB-8100-EPA / LNK - QB-8150-EPR / LNK - QB-8150-LNK-100 - QB-8150-LNK-12/50 - QB-8200-EPA / LNK - QB-8250-EPR / LNK

Category:

Documents


6 download

DESCRIPTION

Operation manual for KO-MAG vacuum oca laminating machine.Global Cell Phone Repair Parts & OCA Refurbishing Machines Wholesale Online Store. Wholesale and retail available worldwide.Email: [email protected] | Tel & Whatsapp: +86 13528895042 | Skype: sales.xicart Website: www.xicart.com

TRANSCRIPT

  • KO-MAG

    ( / / )

    User s Book

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 1. ---------------------------------------

    Safety Regulations

    2. ---------------------------------------

    Parameters and Specification

    3. ---------------------------------------

    Features

    4. -------------------------------------

    Inspection and Alignment

    5. ----------------------------------------

    Operation Process

    6. ----------------------------------------

    Debubbling process

    7. ----------------------------------------

    Maintenance

    8. -------------------------------

    Relation between Vacuum Degree and Altitude

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 1.

    Safety Regulations

    For your safety, please read this handbook carefully to be more familiar

    with the application and limitations of the machines and the related

    potential risks.

    A.

    Read the instructions before using the equipment B.

    Do not boot the equipment before closing the bin gate

    C.

    This machine adopts the third grounding method. It is important to

    keep the grounding normal. Poor grounding will cause the dangers

    towards the machine and user

    D.

    Electricity Box should not be opened without professional staffs are

    present

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 2.

    Parameters AC220V 1500W

    Power:

    AC110V AC220V

    Selective:

    20-30

    Work Environment: 20-30 , clean and dust-free

    Laminating: Flat Type Lamination

    40S/2pcs

    Production Efficiency:

    Heating Method: Constant temperature

    7

    Applicable Size: Below 7

    510*480*380mm

    Size of Equipment: 510*480*380mm

    66kg

    Height of Equipment: About 66kg

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 3.

    Features *

    No Modules Needed, No Debubbling Process Needed

    *

    Press to Boot, Easy Operation

    *

    Smart Constant Pressure; Automatic Shift to the Lamination and

    Debubbling Mode

    *

    Connect the power supply can be used; built-in vacuum pump and air

    compressor;

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 4.

    Inspection and Alignment

    1 2

    Check that whether the tray is smooth Check that whether there are

    some foreign matters on the silicone pad

    3 4

    IC

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • Module Alignment Alignment on the silicone (LCD

    screen is on the silicone

    while IC is beyond the

    silicone

    5 6

    Put into the laminator If the scree is with long flat

    cable, put the product on the

    external part of the anvil cell

    and close the door

    7 2

    mode2 Open the door in

    addition to the bubble machine,

    the product put to

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 5.

    Operation Process 1

    Screen-Pressing Process Mode 1 No Need Remove Bubble

    1.

    Check whether the connected power

    2.

    Switch on the power and press the button to boot the equipment

    to check that whether the equipment can operate normally or not.

    3. OCA IC

    ;

    Put the LCD with the OCA glue on the cut silicone (please stagger

    the silicone away from the IC position of the flat cable)

    4. ;

    Open the gate and put the tray on the cabinet

    5. ;

    Close the cabinet gate

    6. 1

    Switch to the "mode 1" in the control system

    7. ;

    Press button to boot the equipment

    8. 2~6 ;

    Wait patiently for 2 to 6 minutes

    9. ;

    Wait until the two indicator lights off or the vacuum table turns to

    the minimal value. Open the cabinet gate and take out the

    product

    10.

    The process completed, check whether the product is normal or

    not.

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 2

    Screen-Pressing Process Mode 2 In addition to the bubble machine

    usee

    1. 1-5

    Repeat the above steps 1-5

    2. 2

    Switch to the "mode 2" in the control system

    3. ;

    Press button to boot the equipment

    4. 40

    Wait 40 seconds

    5. ;

    Wait until the two indicator lights off or the vacuum table turns to

    the minimal value. Open the cabinet gate and take out the product

    6.

    In addition to the bubble machine by pressing the "open" button

    7. 0

    Wait for the pressure display table is displayed as zero and the

    "open" indicator light;

    8.

    Open the door in addition to the bubble machine, the product put

    to

    9.

    Close and fasten the handle in addition to the bubble machine,

    release the "open" button

    10. 4-10 6-9

    Patiently waiting for 4-10 minutes, then repeat steps 6-9 above, the

    product is taken out

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 7.

    Maintenance

    Projects

    Items

    Formwork

    Check that whether there are some

    foreign matters. If positive, please

    clean them

    Lamination Guide Pillar and Work

    Platform Sideway

    Add some lubricating oil to the

    guide pillar and sideway regularly

    to make sure the movement is

    smooth

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • 8.

    Relation between Vacuum Degree and Altitude

    1

    Generally, the design and tested parameters of the vacuum pump are

    conducted under the standardized air pressure environment. If the

    altitude is changing, the exact performance will also change. The exact

    parameters are displayed in Table 1.

    Altitude

    (m)

    Vacuum Degree

    (-Mpa) mmHg

    0 0.1013 760

    200 0.0990 742.7

    400 0.0968 726.2

    500 0.0957 717.9

    1000 0.0902 676.7

    1500 0.0846 634.7

    2000 0.0790 593.3

    505.9 93~95

    1057.5 88~90

    Examples: Chengdu of Sichuan Altitude 505.9 Vacuum Degree ranges

    from 93 to 95, normal

    Yulin of Shanxi Altitude 1057.5 Vacuum Degree ranges from 88 to 90,

    normal

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com

  • Debugging of Vacuum Pressure Gage 1 Panasonic

    Panasonic Vacuum Pressure Gage Debugging

    2 1

    DP-100

    Only need to press the

    value shown in Table 1

    Main

    displayed in Main

    Sub

    displayed in Sub

    0 /

    0 action is needed (no need for operation) to display the present and

    reference values.

    Global Cell Phone Repair Parts & Machines Wholesale Online Store - Xicart.com