knauf burglar-retardant partitions
TRANSCRIPT
W11RC.de
Knauf Burglar-Retardant Partitions
W118.de – Knauf Burglar-Retardant Security Wall – Single metal stud frameW119.de – Knauf Burglar-Retardant Security Wall – Decoupled double stud frame
2020-12System Data Sheet
Drywall Systems
Note on English translation / Hinweise zur englischen FassungThis is a translation of the System Data Sheet valid in Germany. All stated details and properties are in compliance with the regulations of the German standards and building regulations. They are only applicable for the specified products, system components, application rules, and construction details in connection with the specifications of the respective certificates and approvals.Knauf Gips KG denies any liability for applications outside of Germany as this requires changes acc. to the respective national standards and building regulations.
Dies ist eine Übersetzung des in Deutschland gültigen Detailblattes. Alle angegebenen Werte und Eigenschaften ent-sprechen den in Deutschland gültigen Normen und bauaufsichtlichen Regelungen. Sie gelten nur bei Verwendung der angegebenen Produkte, Systemkomponenten, Anwendungsregeln und Konstruktionsdetails in Verbindung mit den Vorgaben der bauaufsichtlichen Nachweise.Die Knauf Gips KG lehnt jegliche Haftung für Einsatz und Anwendung außerhalb Deutschlands ab, da in diesem Fall eine Anpassung an nationale Normen und bauaufsichtliche Regelungen notwendig ist.
2 W11RC.de Knauf Burglar-Retardant Partitions
ContentsUsage instructions
Notes ................................................................................................................................................................................................4Notes on the document ...............................................................................................................................................................4References to other documents ..................................................................................................................................................4Symbols in the system data sheet ..............................................................................................................................................4Intended use of Knauf Systems ..................................................................................................................................................4General notes on Knauf systems ................................................................................................................................................4Notes on fire resistance ..............................................................................................................................................................4Installation zones acc. to DIN 4103-1 .........................................................................................................................................5Construction notes ......................................................................................................................................................................5Notes on sound insulation ...........................................................................................................................................................5
Proofs of Usability ..........................................................................................................................................................................6
IntroductionSystem overview .............................................................................................................................................................................7
W118.de Security Wall N – Single stud frame .............................................................................................................................7W118.de Security Wall RC2 – Single stud frame ........................................................................................................................8W118.de Security Wall A – Single stud frame .............................................................................................................................9W118.de Security Wall RC3 – Single stud frame ........................................................................................................................9W119.de Security Wall N – Decoupled double stud frame ........................................................................................................10W119.de Security Wall RC2 – Decoupled double stud frame partition .....................................................................................10W119.de Security Wall RC3 – Decoupled double stud frame ................................................................................................... 11
Data for planningW118.de Security Wall N / RC2 – Single metal stud frame ........................................................................................................12
System variants .........................................................................................................................................................................12Partition heights ........................................................................................................................................................................13
W118.de Security Wall A / RC3 – Single stud frame ..................................................................................................................14System variants .........................................................................................................................................................................14Partition heights ........................................................................................................................................................................15
W119.de Security Wall N / RC2 – Decoupled double stud frame ..............................................................................................16System variants .........................................................................................................................................................................16Partition heights ........................................................................................................................................................................17
W119.de Security Wall RC3 – Decoupled double stud frame ...................................................................................................18System variants .........................................................................................................................................................................18Partition heights ........................................................................................................................................................................19
Cantilever loads I Fixing loads ....................................................................................................................................................20
Construction detailsW118.de Security Wall N – With sheet metal insert ...................................................................................................................21
Single metal stud frame – 2x Diamant + sheet metal insert .....................................................................................................21W118.de Security Wall N – With sheet metal insert ...................................................................................................................23
Single metal stud frame – Solid Board+ Diamant + sheet metal insert .....................................................................................23W118.de Security Wall RC2 – lead free .......................................................................................................................................25
Single metal stud frame – Solid Board + Diamant ....................................................................................................................25W118.de Security wall RC2 – With Diamant Steel GKFI ............................................................................................................28
Single metal stud frame – Diamant Steel GKFI + Diamant .......................................................................................................28W118.de Security Wall A – With sheet metal inserts .................................................................................................................31
Single metal stud frame – 2x Diamant + sheet metal inserts ....................................................................................................31W118.de Security Wall A – With sheet metal inserts .................................................................................................................33
Single metal stud frame – 3x Diamant + sheet metal inserts ....................................................................................................33W118.de Security wall RC3 – With Diamant Steel GKFI ............................................................................................................35
Single metal stud frame – 2x Diamant Steel GKFI ....................................................................................................................35
3W11RC.de Knauf Burglar-Retardant Partitions
Construction detailsW119.de Security Wall N – With sheet metal insert ...................................................................................................................38
Decoupled double stud frame – 2x Diamant + sheet metal insert .............................................................................................38W119.de Security Wall RC2 – lead free .......................................................................................................................................40
Double metal stud frame – Solid Board + Diamant ..................................................................................................................40W119.de Security wall RC2 – With Diamant Steel GKFI ............................................................................................................43
Decoupled double metal stud frame – Diamant Steel GKFI + Diamant ....................................................................................43W119.de Security wall RC3 – With Diamant Steel GKFI ............................................................................................................46
Decoupled double stud frame – 2x Diamant Steel GKFI ..........................................................................................................46
Special versionsSingle side installation .................................................................................................................................................................49Door openings ..............................................................................................................................................................................50
Installation and applicationStud frame .....................................................................................................................................................................................52
Stud frame .................................................................................................................................................................................52Insulation layer ..........................................................................................................................................................................54
Cladding ........................................................................................................................................................................................55Installation schemes ..................................................................................................................................................................55Fastening of the cladding to the stud frame with Knauf drywall screws ....................................................................................56
Built-ins .........................................................................................................................................................................................57Jointing ..........................................................................................................................................................................................58Coatings and linings ....................................................................................................................................................................59
Information on sustainabilityKnauf Burglar-Retardant Partitions ............................................................................................................................................60
Information on sustainability of Knauf burglar-retardant partitions ............................................................................................60
4 W11RC.de Knauf Burglar-Retardant Partitions
Usage instructionsNotes
Notes on the documentKnauf system data sheets are the planning and application basis for planners and professional installers with the application of Knauf systems. The contained information and specifications, constructions, details and stated products are based, unless otherwise stated, on the certificates of usability (e.g. National Technical Test Certificate (e.g. abP) valid at the date they are published as well as on the applicable standards. Additionally, design and structural requirements and those relating to building physics (fire resistance and sound insulation) are considered.The contained construction details are examples and can be used in a similar way for various cladding variants of the respective system. At the same time, the demands made on fire resistance and/or sound insulation as well as any necessary additional measures and/or limitations must be observed.
References to other documentsSystem data sheet
■ Knauf Firewalls W13.de ■ Knauf Metal Stud Partitions W11.de ■ Knauf Bullet-Resistant Walls W16.de
Product data sheets ■ Observe the product data sheets of the Knauf system components
Technical Information ■ Fastening of loads to Knauf Wall and Ceiling Systems VT03.de
Folders ■ Fire resistance with Knauf BS1.de (German only) ■ Sound insulation and room acoustics with Knauf (only sections in English)
Symbols in the system data sheetThe following symbols are used in this document:Insulation layersG Mineral wool insulation layer acc. to EN 13162
Non-combustible (insulating material, e.g. from Knauf Insulation)
Intended use of Knauf SystemsPlease observe the following:
Caution
Knauf systems may only be used for the application cases as stated in the Knauf documentation. In case third-party products or components are used, they must be recommended or approved by Knauf. Flawless application of products/systems assumes proper transport, storage, assembly, installation and maintenance.
General notes on Knauf systems
Term definitionsBurglar-retardant is the property of components to resist attempts to gain access to the protected room or area by using physical force with the aid of tools. Burglar-retardant constructions can also be used to develop break-out resistant construction methods, as required in prisons or police stations.The resistance classes class N acc. to VdS 2534 / RC2 acc. to DIN EN 1627 and class A acc. to VdS 2534 / RC3 acc. to DIN EN 1627 refer to the level of the break-in effort and method generally applied by an opportunistic burglar. It is assumed that these break-in attempts are triggered by opportunities that present themselves without the expectation of a very valuable haul in the event of a successful break-in. There is no use of excessive force and the tools used are generally available hand and lifting tools. The break-in methods described from these classes usually try to avoid noise and take unnecessary risks. The risk increases the longer the time required, and time taken to gain entry is limited and varies according to the resistance classes.Classification test times
Class Resistance time
Total test timeVdS 2534:2013-07 DIN EN 1627:2011-09
N RC2 (WK21)) 3 min. 15 min.A RC3 (WK31)) 5 min. 20 min.
1) Previous designation acc. to DIN EN 1627:1999-04 / DIN 18106:2003-09RC = Resistance ClassWK = Widerstandsklasse (resistance class)
NoteIn the following, the proofs are only differentiated acc. to class N/A or RC2/RC3. The basis for the proofs is related to the above mentioned guideline or standard.
Field of applicationThe specifications in this system data sheet only apply for burglar-retardant metal stud partitions in interiors. Burglar-retardant partitions offer protection where there is a need for increased security.
■ Banks ■ Prisons ■ Public buildings ■ Company buildings ■ Sales rooms for premium quality goods, e.g. jewellers, electronics, etc. ■ Residential buildings - party walls
Notes on fire resistanceReinforcing and supporting connection components must at least feature the same fire resistance class.
Installation zones acc. to DIN 4103-1
W11
9.de
W11
8.de
5W11RC.de Knauf Burglar-Retardant Partitions
Usage instructionsNotes
Installation zone 1Partitions in rooms where low numbers of persons gather, e.g. dwellings, hotels, office and hospital rooms including corridors and halls or similar.Installation zone 2Partitions in rooms where large numbers of persons gather, e.g. meeting halls, school classrooms, auditoria, exhibition halls and sales rooms as well as rooms with a similar use.Unless otherwise stated, the value in the table is the maximum permissible partition height for installation zone 2.
Construction notesMovement jointsMovement joints of the main structure should be integrated into the construction of the burglar-retardant partitions. Movement joints are to be installed every 15 m on continuous burglar-retardant partitions.
Notes on sound insulationRw = Weighted sound reduction index in dB without sound
transmission via flanking building componentsRw,R = Calculation value of the weighted apparent sound reduction
index without sound transmission via flanking building components
Index R = Used to differentiate between the calculation values and the test values.
Note
The verification acc. to DIN 4109-2:2018-01 is no longer according to calculation values Rw,R, but rather with the values obtained on the test rig Rw rounded off to a single position following the decimal point. Only at the end of the forecast after consideration of all the perimeter surfaces (flanking surfaces) involved in the transmission of sound is an element of forecast uncertainty included in dependence on the type of separating constructional component.For a transition period, the Knauf system data sheets will specify both the test stand values as well as the calculated values used up to now.
W11
9.de
W11
8.de
6 W11RC.de Knauf Burglar-Retardant Partitions
Usage instructionsProofs of Usability
Proof of UsabilityKnauf system
Burglarretardant
Fire resistance Structural Ball impact safety Sound insulation
W118.de N M 108302
AbP P-3310/563/07-MPA BS
AbP P-1405/928/10-MPA BS
903 1260 000 /man/Sgm
Knauf sound insulation proof L 016-04.17L 015-12.18L 058-07.07
W118.de RC2 (lead free) 18-001289-PR07W118.de RC2 (Diamant Steel GKFI) 18-001289-PR05W118.de A M 196119W118.de RC3 (Diamant Steel GKFI) 18-001289-PR06W119.de N M 108302
AbP P-1100/490/15-MPA BS
W119.de RC2 (lead free) 18-001289-PR07W119.de RC2 (Diamant Steel GKFI) 18-001289-PR05W119.de RC3 (Diamant Steel GKFI) 18-001289-PR06
The stated constructional and structural properties, and characteristic building physics of Knauf systems can solely be ensured with the exclusive use of Knauf system components, or other products expressly recommended by Knauf. The validity and up-to-datedness of the stated proofs have to be considered.Notes on fire resistanceThe specifications marked with offer additional application options, which are not directly included in the Proof of Usability. On the basis of our technical assessments, we assume that these marked design solutions can be assessed as a non-significant divergence. On request, we can make the documentation on which this assessment is based, such as experts opinions or technical assessments, available to you together with the Certificate of Usability. We recommend that a non-significant divergence be coordinated and authorised in advance in consultation between the persons responsible for fire resistance and/or the relevant authorities.
W11
9.de
W11
8.de
7W11RC.de Knauf Burglar-Retardant Partitions
IntroductionSystem overview
Knauf Burglar-Retardant PartitionsDrywall partitions with stud frames made of sheet metal profiles and cladding on both sides made of gypsum boards with/without sheet metal inserts or gypsum boards with sheet steel lamination. Depending on the cladding variation, Knauf Security Walls as burglar-retardant stud partitions achieve resistance class N or A acc. to the VdS (German liability insurance association) or alt. RC2 or RC3 acc. to DIN EN 1627 to 1630.
W118.de Security Wall N – Single stud frameW118.de Security Wall N Single stud frame – 2x Diamant + sheet metal insert
W118.de Security Wall N Single stud frame – Solid Board + Diamant + sheet metal insert
The security wall W118.de N consists of a single metal stud frame and cladding on both sides made of two layers of Knauf Diamant board with sheet metal insert between the cladding layers. They achieve burglar-retardant classification of resistance class N.
■ Partition heights up to: 12.00 m ■ Weighted airborne sound insulation index Rw up to: 68.2 dB ■ Fire resistance class up to: F90
The security wall W118.de N consists of a single metal stud frame and cladding on both sides made of a layer of Knauf Solid Board as well as a cover layer of Knauf Diamant boards with a sheet metal insert between the cladding layers. They achieve burglar-retardant classification of resistance class N.
■ Suitable as a party wall ■ Partition heights up to: 12.00 m ■ Weighted airborne sound insulation index Rw up to: 70.5 dB ■ Fire resistance class up to: F90
Note
Construction as a bullet-resistant partition FB4 is possible.For further information on planning and design, see system data sheet Knauf Bullet-Resistant Walls W16.de
W11
9.de
W11
8.de
8 W11RC.de Knauf Burglar-Retardant Partitions
IntroductionSystem overview
W118.de Security Wall RC2 Single stud frame – Solid Board + Diamant
W118.de Security Wall RC2 Single stud frame – Diamant Steel GKFI + Diamant
Knauf Burglar-Retardant Partitions (continued)W118.de Security Wall RC2 – Single stud frame
The security wall W118.de RC2 consists of a single metal stud frame and lead-freer cladding on both sides made of a layer of Knauf Solid Board as well as a layer of Knauf Diamant board. They achieve burglar-retardant classification of resistance class RC2.
■ Lead-free and particularly cost-effective design. ■ Suitable as a party wall ■ Partition heights up to: 12.00 m ■ Weighted airborne sound insulation index Rw up to: 68.0 dB ■ Fire resistance class up to: F90
The security wall W118.de RC2 consists of a single metal stud frame and double-sided cladding made or a layer of Knauf Diamant Steel GKFI boards with sheet metal lamination as well as a cover layer of Knauf Diamant boards. They achieve burglar-retardant classification of resistance class RC2.
■ Partition heights up to: 12.00 m ■ Weighted airborne sound insulation index Rw up to: 67.8 dB ■ Fire resistance class up to: F90
Note
Construction as a bullet-resistant partition FB4 is possible.For further information on planning and design, see system data sheet Knauf Bullet-Resistant Walls W16.de
W11
9.de
W11
8.de
9W11RC.de Knauf Burglar-Retardant Partitions
IntroductionSystem overview
W118.de Security Wall A Single stud frame – 2x Diamant + sheet metal inserts
W118.de Security Wall A Single stud frame – 3x Diamant + sheet metal inserts
W118.de Security Wall RC 3 Single stud frame – 2x Diamant Steel GKFI
The security wall W118.de A consists of a single metal stud frame and cladding on both sides made of two layers of Knauf Diamant board with sheet metal inserts directly on the grid and between the cladding layers. They achieve burglar-retardant classification of resistance class A.
■ Partition heights up to: 12.00 m ■ Weighted airborne sound insulation index Rw up to: 68 dB ■ Fire resistance class up to: F90
The security wall W118.de A consists of a single metal stud frame and cladding on both sides made of three layers of Knauf Diamant board with sheet metal inserts between the cladding layers. They achieve burglar-retardant classification of resistance class A.
■ Partition heights up to: 12.00 m ■ Weighted airborne sound insulation index Rw up to: 71.7 dB ■ Fire resistance class up to: F90
The security wall W118.de RC3 consists of a single metal stud frame and double-sided cladding made of two layers of Knauf Diamant Steel GKFI boards with sheet metal lamination. They achieve burglar-retardant classification of resistance class RC3.
■ Enhanced cantilever loads ■ Slim design ■ Partition heights up to: 12.00 m ■ Weighted airborne sound insulation index Rw up to: 69.6 dB ■ Fire resistance class up to: F90
Knauf Burglar-Retardant Partitions (continued)W118.de Security Wall A – Single stud frame
Note
Construction as a bullet-resistant partition FB4 is possible.For further information on planning and design, see system data sheet Knauf Bullet-Resistant Walls W16.de
W118.de Security Wall RC3 – Single stud frame
W11
8.de
W11
9.de
10 W11RC.de Knauf Burglar-Retardant Partitions
IntroductionSystem overview
W119.de Security Wall N Decoupled double stud frame – 2x Diamant + sheet metal insert
W119.de Security Wall RC2 Double metal stud frame – Solid Board + Diamant
W119.de Security Wall RC2 Decoupled double metal stud frame – Diamant Steel GKFI + Diamant
The security wall W119.de N consists of a double metal stud frame and cladding on both sides made of two layers of Knauf Diamant board with sheet metal insert between the cladding layers. They achieve burglar-retardant classification of resistance class N.
■ Suitable as a party wall ■ Partition heights up to: 9.70 m ■ Weighted airborne sound insulation index Rw up to: 74 dB ■ Fire resistance class up to: F90
The security wall W119.de RC2 consists of a double frame stud frame and lead-free cladding on both sides made of a layer of Knauf Solid Board as well as a layer of Knauf Diamant board. They achieve burglar-retardant classification of resistance class RC2.
■ Lead-free and particularly cost-effective design. ■ Suitable as a party wall ■ Partition heights up to: 10.15 m ■ Weighted airborne sound insulation index Rw up to: 74 dB ■ Fire resistance class up to: F90
The security wall W119.de RC2 consists of a double metal stud frame and double-sided cladding made or a layer of Knauf Diamant Steel GKFI boards with sheet metal lamination as well as a cover layer of Knauf Diamant boards. They achieve burglar-retardant classification of resistance class RC2.
■ Suitable as a party wall ■ Enhanced cantilever loads ■ Partition heights up to: 9.70 m ■ Weighted airborne sound insulation index Rw up to: 74 dB ■ Fire resistance class up to: F90
Knauf Burglar-Retardant Partitions (continued)W119.de Security Wall N – Decoupled double stud frame
W119.de Security Wall RC2 – Decoupled double stud frame partition
W11
8.de
W11
9.de
11W11RC.de Knauf Burglar-Retardant Partitions
IntroductionSystem overview
W119.de Security Wall RC3 Decoupled double metal stud frame – 2x Diamant Steel GKFI
The security wall W119.de RC3 consists of a double metal stud frame and double-sided cladding made of two layers of Knauf Diamant Steel GKFI boards with sheet metal lamination. They achieve burglar-retardant classification of resistance class RC3.
■ Suitable as a party wall ■ Enhanced cantilever loads ■ Partition heights up to: 9.70 m ■ Weighted airborne sound insulation index Rw up to: 74 dB ■ Fire resistance class up to: F90
Knauf Burglar-Retardant Partitions (continued)W119.de Security Wall RC3 – Decoupled double stud frame
W11
8.de
W11
9.de
12 W11RC.de Knauf Burglar-Retardant Partitions
System variantsKnauf system
Fire
resis
tanc
e clas
s
Cladding per wall side Weight Wall thick-ness
ProfilesKnaufCW
Insulation layer Sound insulationD
th
t
Solid
Boa
rd
Diam
ant
Diam
ant S
teel
GKFI
Required for fire resistance
Insu-lation layer
Sound reduction index
Min.thickness
Withoutinsu-lation layer
Cavity Min.thick-ness
Min. density
Min.thick-ness
mmtmm
Approx.kg/m²
Dmm
hmm mm kg/m³
Rw dB
Rw,R dB
W118.de Security Wall N Single metal stud frame – double-layer cladding + sheet metal insert
Stud spacinga
F90
● 2x 12.5+Sheet metal insert1x 0.5 mm
64
101 50 40 64.61) 62
126 75 Without 60 66 64
151 100 80 68.21) 66
Stud spacinga
F90
●
●
25+12.5+Sheet metal insert1x 0.5 mm
83
126 50 40 – –
151 75 Without 60 70.5 68
176 100 80 70 68
W118.de Security Wall RC2 Single metal stud frame – double-layer cladding metal-free / with Diamant Steel GKFI
Stud spacinga
F90●
●
25+12.5
74
125 50 40 64.4 62
150 75 Without 60 66.2 64
175 100 80 68.0 66
Stud spacinga
F90●
● 12.5 + 0.4+12.5
62
101 50 40 63.8 61
126 75 Without 60 65.2 63
151 100 80 67.8 65
1) Measured with stud spacing 312.5 mm.
■ Always use Diamant as a covering layer with combined claddingSound reduction index values represented in italics are derived values from measurements on divergent constructions.Sheet metal acc. to EN 10130 and EN 10152, as plates of material or rolls, galvanized, nominal metal thickness ≥ 0.5 mm. Stagger the joints by at least 100 mm.Demands on the insulation layer (Insulation materials, e.g. from Knauf Insulation):
■ Required for fire resistance: None
■ Fire protection permissible: Mineral wool G
■ Required for sound insulation: Mineral wool G length-related flow resistance acc. to EN 29053: r ≥ 5 kPa • s/m²
Data for planningW118.de Security Wall N / RC2 – Single metal stud frame
Note Observe the notes from page 4.
Extension of the fire resistance Proof of Usability ■ For sheet metal inserts / Diamant Steel GKFI application ■ For horizontal board application Solid Board
Prior consultation is recommended acc. to page 6.
W11
9.de
W11
8.de
13W11RC.de Knauf Burglar-Retardant Partitions
Data for planningW118.de Security Wall N / RC2 – Single metal stud frame
Note Observe the notes from page 4.
Partition heightsMaximum permissible wall heights
Knauf profile
Stud spacing W118.de Security Wall N / RC2 – Single metal stud frame
aWithoutFire resistance
WithFire resistance
mm m m
CW 50625 4.75 4.75417 5.40 5.40312.5 5.80 5.80
CW 75625 7.20 7.00417 7.85 7.00312.5 8.20 7.00
CW 100625 9.30 7.00417 9.75 7.00312.5 10.00 7.00
CW 125625 10.80 7.00417 11.20 7.00312.5 11.55 7.00
CW 150625 12.00 7.00417 12.00 7.00312.5 12.00 7.00
Ball impact safetyBall impact safety acc. to DIN 18032-3
Installation zones 1 and 2
Extension of the fire resistance Proof of Usability ■ For sheet metal inserts / Diamant Steel GKFI application ■ For horizontal board application Solid Board
Prior consultation is recommended acc. to page 6.
W11
9.de
W11
8.de
14 W11RC.de Knauf Burglar-Retardant Partitions
Data for planningW118.de Security Wall A / RC3 – Single stud frame
System variantsKnauf system
Fire
resis
tanc
e clas
s
Cladding per wall side Weight Wall thick-ness
ProfilesKnaufCW
Insulation layer Sound insulationD
th
t
Solid
Boa
rd
Diam
ant
Diam
ant S
teel
GKFI
Required for fire resistance
Insu-lation layer
Sound reduction index
Min.thickness
Withoutinsu-lation layer
Dmm
Cavity Min.thick-ness
Min. density
Min.thick-ness
mmtmm
Approx.kg/m²
hmm mm kg/m³
Rw dB
Rw,R dB
W118.de Security Wall A Single metal stud frame, double/triple-layer cladding + sheet metal inserts
Stud spacinga
F90
● 2x 12.5+Sheet metal in-serts2x 0.5 mm
74
102 50 40 ≥ 64 62
127 75 Without 60 ≥ 66 64
152 100 80 ≥ 68 66
Stud spacinga
F90
● 3x 12.5+Sheet metal in-serts2x 0.5 mm
100
127 50 40 68.71) 66
152 75 Without 60 69 67
177 100 80 71.71) 69
W118.de Security Wall RC3 Single metal stud frame – Double-layer cladding with Diamant Steel GKFI
Stud spacinga
F90 ● 2x 12.5 + 0.4 68
102 50 40 65.3 63
127 75 Without 60 66.0 64
152 100 80 69.6 67
1) Measured with stud spacing 312.5 mm.Sound reduction index values represented in italics are derived values from measurements on divergent constructions.Sheet metal acc. to EN 10130 and EN 10152, as plates of material or rolls, galvanized, nominal metal thickness ≥ 0.5 mm. Stagger the joints by at least 100 mm.Demands on the insulation layer (Insulation materials, e.g. from Knauf Insulation):
■ Required for fire resistance: None
■ Fire protection permissible: Mineral wool G
■ Required for sound insulation: Mineral wool G length-related flow resistance acc. to EN 29053: r ≥ 5 kPa • s/m²
Extension of the fire resistance Proof of Usability ■ For sheet metal inserts / Diamant Steel GKFI application
Prior consultation is recommended acc. to page 6. Note Observe the notes from page 4.
W11
9.de
W11
8.de
15W11RC.de Knauf Burglar-Retardant Partitions
Data for planningW118.de Security Wall A / RC3 – Single stud frame
Partition heightsMaximum permissible wall heights
Knauf profile Stud spacing
a
W118.de Security Wall A / RC3 – Single stud frameDouble-layer Triple-layerWithoutFire resistance
WithFire resistance
WithoutFire resistance
WithFire resistance
mm m m m m
CW 50625 4.75 4.75 7.65 7.65417 5.40 5.40 8.15 8.15312.5 5.80 5.80 8.45 8.45
CW 75625 7.20 7.00 9.85 9.00417 7.85 7.00 10.20 9.00312.5 8.20 7.00 10.40 9.00
CW 100625 9.30 7.00 11.50 9.00417 9.75 7.00 11.85 9.00312.5 10.00 7.00 12.00 9.00
CW 125625 10.80 7.00 12.00 9.00417 11.20 7.00 12.00 9.00312.5 11.55 7.00 12.00 9.00
CW 150625 12.00 7.00 12.00 9.00417 12.00 7.00 12.00 9.00312.5 12.00 7.00 12.00 9.00
Ball impact safetyBall impact safety acc. to DIN 18032-3
Installation zones 1 and 2
Extension of the fire resistance Proof of Usability ■ For sheet metal inserts / Diamant Steel GKFI application
Prior consultation is recommended acc. to page 6. Note Observe the notes from page 4.
W11
9.de
W11
8.de
16 W11RC.de Knauf Burglar-Retardant Partitions
System variantsKnauf system
Fire
resis
tanc
e clas
s
Cladding per wall side Weight Wall thick-ness
ProfilesKnaufCW
Insulation layer Sound insulationD
th
t
Solid
Boa
rd
Diam
ant
Diam
ant S
teel
GKFI
Required for fire resistance
Insu-lation layer
Sound reduction index
Min.thickness
WithoutInsu-lation layer
Cavity Min.thick-ness
Min. density
Min.thick-ness
tmm
Approx.kg/m²
Dmm
hmm mm kg/m³ mm
Rw dB
Rw,R dB
W119.de Security Wall N Decoupled double stud frame – Double-layer cladding + sheet metal insert
Stud spacinga
F90
● 2x 12.5+Sheet metal insert1x 0.5 mm
67
156 2x 50105 2x 40 ≥ 69 ≥ 66
206 2x 75155 Without 2x 60 ≥ 72 ≥ 70
256 2x 100205 2x 80 ≥ 74 ≥ 72
W119.de Security Wall RC2 Double metal stud frame – Double-layer cladding metal-free / with Diamant Steel GKFI
Stud spacinga
F90●
●
25+ 12.5
76
180 2x 50105 2x 40 ≥ 69 ≥ 66
230 2x 75155 Without 2x 60 ≥ 72 ≥ 70
280 2x 100205 2x 80 ≥ 74 ≥ 72
Stud spacinga
F90●
● 12.5 + 0.4+12.5
64
156 2x 50105 2x 40 72.9 70
206 2x 75155 Without 2x 60 ≥ 72 ≥ 70
256 2x 100205 2x 80 ≥ 74 ≥ 72
■ Always use Diamant as a covering layer with combined claddingSound reduction index values represented in italics are derived values from measurements on divergent constructions.Sheet metal acc. to EN 10130 and EN 10152, as plates of material or rolls, galvanized, nominal metal thickness ≥ 0.5 mm. Stagger the joints by at least 100 mm.Demands on the insulation layer (Insulation materials, e.g. from Knauf Insulation):
■ Required for fire resistance: None
■ Fire protection permissible: Mineral wool G
■ Required for sound insulation: Mineral wool G length-related flow resistance acc. to EN 29053: r ≥ 5 kPa • s/m²
Data for planningW119.de Security Wall N / RC2 – Decoupled double stud frame
Extension of the fire resistance Proof of Usability ■ For sheet metal inserts / Diamant Steel GKFI application ■ For horizontal board application Solid Board
Prior consultation is recommended acc. to page 6. Note Observe the notes from page 4.
W11
8.de
W11
9.de
17W11RC.de Knauf Burglar-Retardant Partitions
Data for planningW119.de Security Wall N / RC2 – Decoupled double stud frame
Partition heightsMaximum permissible wall heights
Knauf profiles
Stud spacing W119.de Security Wall N / RC2 – Decoupled double stud frame
Solid board 25 mm + Diamant 12.5 mm Diamant 2x 12.5 mm + 0.5 mm sheet metal insert /Diamant Steel GKFI 12.5 + 0.4 + Diamant 12.5 mm
aWithoutFire resistance
WithFire resistance
WithoutFire resistance
WithFire resistance
mm m m m m
CW 50625 4.00 4.00 3.351) 3.351)
417 4.00 4.00 4.00 4.00312.5 4.00 4.00 4.00 4.00
CW 75625 4.15 4.15 4.00 4.00417 4.95 4.95 4.40 4.40312.5 5.55 5.55 4.95 4.95
CW 100625 5.40 5.40 4.95 4.95417 6.45 6.45 5.90 5.90312.5 7.20 7.00 6.65 6.65
CW 125625 6.80 6.80 6.30 6.30417 8.00 7.00 7.50 7.00312.5 8.90 7.00 8.35 7.00
CW 150625 8.20 7.00 7.70 7.00417 9.40 7.00 9.00 7.00312.5 10.15 7.00 9.70 7.00
1) only for installation zone 1
Ball impact safetyBall impact safety acc. to DIN 18032-3
Installation zones 1 and 2
Extension of the fire resistance Proof of Usability ■ For sheet metal inserts / Diamant Steel GKFI application ■ For horizontal board application Solid Board
Prior consultation is recommended acc. to page 6. Note Observe the notes from page 4.
W11
8.de
W11
9.de
18 W11RC.de Knauf Burglar-Retardant Partitions
System variantsKnauf system
Fire
resis
tanc
e clas
s
Cladding per wall side Weight Wall thick-ness
ProfilesKnaufCW
Insulation layer Sound insulationD
th
t
Solid
Boa
rd
Diam
ant
Diam
ant S
teel
GKFI
Required for fire resistance
Insu-lation layer
Sound reduction index
Min.thickness
Withoutinsu-lation layer
Cavity Min.thick-ness
Min. density
Min.thick-ness
tmm
Approx.kg/m²
Dmm
hmm mm kg/m³ mm
Rw dB
Rw,R dB
W119.de Security Wall RC3 Decoupled double metal stud frame – Double-layer cladding with Diamant Steel GKFI
Stud spacinga
F90 ● 2x 12.5 + 0.4 71
157 2x 50105 2x 40 72.1 70
207 2x 75155 Without 2x 60 ≥ 72 ≥ 70
257 2x 100205 2x 80 ≥ 74 ≥ 72
Sound reduction index values represented in italics are derived values from measurements on divergent constructions.Demands on the insulation layer (Insulation materials, e.g. from Knauf Insulation):
■ Required for fire resistance: None
■ Fire protection permissible: Mineral wool G
■ Required for sound insulation: Mineral wool G length-related flow resistance acc. to EN 29053: r ≥ 5 kPa • s/m²
Data for planningW119.de Security Wall RC3 – Decoupled double stud frame
Extension of the fire resistance Proof of Usability ■ For application with Diamant Steel GKFI
Prior consultation is recommended acc. to page 6. Note Observe the notes from page 4.
W11
8.de
W11
9.de
19W11RC.de Knauf Burglar-Retardant Partitions
Data for planningW119.de Security Wall RC3 – Decoupled double stud frame partition
Partition heightsMaximum permissible wall heights
Knauf profiles
Stud spacing W119.de Security Wall RC3 – Decoupled double stud frame partition
aWithoutFire resistance
WithFire resistance
mm m m
CW 50625 3.351) 3.351)
417 4.00 4.00312.5 4.00 4.00
CW 75625 4.00 4.00417 4.40 4.40312.5 4.95 4.95
CW 100625 4.95 4.95417 5.90 5.90312.5 6.65 6.65
CW 125625 6.30 6.30417 7.50 7.00312.5 8.35 7.00
CW 150625 7.70 7.00417 9.00 7.00312.5 9.70 7.00
1) only for installation zone 1
Ball impact safetyBall impact safety acc. to DIN 18032-3
Installation zones 1 and 2
Extension of the fire resistance Proof of Usability ■ For application with Diamant Steel GKFI
Prior consultation is recommended acc. to page 6. Note Observe the notes from page 4.
W11
8.de
W11
9.de
20 W11RC.de Knauf Burglar-Retardant Partitions
Data for planningCantilever loads I Fixing loads
Cantilever loads
Cabinet widthCabinetdepth
Cabin
et he
ight
≥ 30
0 mm
≤ 600 mm≤ 1200 mm
Eccentricity≤ 300 mm
■ According to DIN 18183-1, stud partitions can be loaded at any position by cantilever loads (e.g. TVs, wall cupboards).
■ Consideration of the cantilever arm (cabinet height ≥ 300 mm) and eccentricity (≤ 300 mm at cabinet depth ≤ 600 mm) is required.
■ Attach the cantilever loads with at least 2 cavity dowels made of plastic or metal, e.g. Knauf Hartmut Hohlraumdübel cavity dowels.
■ Determine the minimum number of dowels using the cabinet weight and loading of the selected dowel type in dependence on the cladding thickness.
■ Fixing spacing of the dowels according to DIN 18183-1: ≥ 75 mm; (Knauf recommendation for approach to the full loadbearing capacity at ≥ 250 mm).
■ Observe the permissible cantilever load of the wall system.
Note For further details for planning, application and dynamic loads see technical information VT03.de Fastening of Loads to Knauf Wall and Ceiling Systems.
Application of Diamant Steel GKFI for increased loadsSelection of the grid in dependence on the expected load
Load max.
kN/m2
Load type
Profile min.
Cladding thickness min. Double metalstud partition possible
Loaded side Unloaded sideDiamant Diamant Steel
GKFIMinimum thickness tmm
Diamant Diamant Steel GKFI
Minimum thickness tmm
0.7 Static CW 50 ● 12.5 + 0.4 ● 12.5 + 0.4 Yes 2)
1.0 StaticCW 50
●
● 12.5 + 0.41)
+ 12.5
● 2x 12.5 Yes 2)
CW 75 ● 12.5 + 0.4 ● 12.5 No
1.5 Static CW 75●
● 12.5 + 0.4+ 12.5
● 2x 12.5 No
1) Drywall screw spacing XTB 1st layer Diamant Steel GKFI ≤ 250 mm.2) In case of application of partition heights acc. to DIN 18183-1 only cantilever loads up to 0.4 kN/m are possible
Fixing loadsFixing loads for anchoring cantilever loads in Diamant Steel GKFI
Cladding Maximum screw / dowel load capacity in kgKnauf Cavity Dowel Hartmut Screw M5
fischer MHD 5 x 65 SScrew M5 or M6
Knauf Multi-Purpose Screw FN 4.3 x 65
fischer UX 8 x 50 with Knauf Multi-Purpose Screw FN 4.3 x 65
1-layer 80 50 30 302-layers 100 90 60 55
■ Tested with an eccentricity of 300 mm. ■ Dowel load capacity of other fasteners acc. to manufacturer`s specifications.
Notes
Static loads in this respect are permanently fastened loads such as towel rails, cabinets, shelves and boilers.Further details for planning, application and dynamic loads see
■ Technical information VT03.de Fastening of loads to Knauf Wall and Ceiling Systems ■ System data sheet W11.de Knauf Metal Stud Partitions
W11
9.de
W11
8.de
21W11RC.de Knauf Burglar-Retardant Partitions
Construction detailsW118.de Security Wall N – With sheet metal insert
W118.de-P100 Vertical board layers W118.de-VO100 Connection to ceiling on basic ceiling – N2x 12.5 mm Diamant + 1x 0.5 mm sheet metal insert Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-A100 Connection to solid wall – N W118.de-VM100 Board joint – NHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-B100 Board joint – N W118.de-VU100 Connection to floor on basic floor – NHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Uniflott + Trenn-FixTrennwandkitt acoustical sealante.g. Knauf Drehstiftdübel nailable plugs
Connect the CW stud to theUW runner with blind steel rivets
Trennwandkitt acoustical sealantCW stud
1x galvanized sheet metal ≥ 0.5 mm thick
Diamant Screw XTNe.g. Knauf Drehstiftdübel nailable plug
Uniflott + Trenn-Fix
2x 12.5 mm Diamant
Diamant Screw XTNUniflott
CW stud2x 12.5 mm Diamant1x galvanized sheet metal ≥ 0.5 mm thick, joint overlap ≥ 100 mm
Diamant Screw XTN1x galvanized sheet metal ≥ 0.5 mmthick, joint overlap ≥ 100 mm
2x 12.5 mm Diamant
UniflottConnect the CW stud to the UW runnerusing steel blind rivets
UW runner
2x 12.5 mm Diamant
1x galvanized sheet metal≥ 0.5 mm thick
Uniflotte.g. Knauf Drehstiftdübel nailable plugs
Connect the CW stud with theUW runner using steel blind rivets
Scale 1:5Single metal stud frame – 2x Diamant + sheet metal insert
W11
9.de
W11
8.de
22 W11RC.de Knauf Burglar-Retardant Partitions
Single metal stud frame – 2x Diamant + sheet metal insert
Construction detailsW118.de Security Wall N – With sheet metal insert
W118.de-A101 Connection to metal stud partition – N W118.de-D100 Corner – NHorizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-BFU101 Movement joint – N W118.de-VO101 Connection to ceiling, deflection head – N 1)
Horizontal section Vertical section
a ≤ 20 mm
aaa 20≥
20≥
≤ 200
DiamantScrew XTN
1x galvanized sheet metal≥ 0.5 mm thick
2x 12.5 mmDiamant UW runner CW stud
UW runnerUA profile
Metal Screw LB 3.5 x 9.5; a ≤ 250 mm
Diamant Screw XTB Corner trim if required
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1x galvanized sheet metal ≥ 0.5 mm thick2x 12.5 mm Diamant Knauf Multi-Purpose Screw FN 4.3 x 65; a ≤ 250 mmDiamant XTN1x galvanized sheet metal ≥ 0.5 mm thick
CW stud
UW runner
Uniflott
Trennwandkittacoustical sealant
Sheet metal if required
Uniflott
2x 12.5 mm Diamant1x galvanized sheet metal ≥ 0.5 mm thick
CW studKnauf Multi-Purpose Screw FN 4.3 x 65; a ≤ 250 mm
CW studDiamant Screw XTN
If necessarycorner trim or edge trim Dallas 90°
≥ 20
ab
a+
5a
Knauf board strips(height dependent on theceiling deflection)
Fastener suitable for the substrateØ ≥ 6 mm; a ≤ 500 mm; fixed withoffset, install according tocertification or double setting depth
Knauf angle profile 50/35/0,7
Permanently elastic seal e.g.Knauf Insulation LDS Solimur
e.g. Knauf designelement
≥ 20
Do notscrew
fasten tothe UWrunner
UW runner
Dimensions in mm I Scale 1:5
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissiblepartition height
amm
bmm
amm
bmm m
≤ 30 ≥ 10 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 13)Influence of a deflection head on the sound reduction index
■ W118.de Overall -3 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not rivet the profiles. Do not screw fasten the boards to the UW runners.
■ See also Knauf YouTube Channel
W11
9.de
W11
8.de
23W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5Single metal stud frame – Solid Board+ Diamant + sheet metal insert
Construction detailsW118.de Security Wall N – With sheet metal insert
W118.de-P200 Board layer 1 horizontal, board layer 2 vertical W118.de-VO200 Connection to ceiling on basic ceiling – N25 mm Solid Board + 12.5 mm Diamant + 1x 0.5 mm sheet metal insert Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-A200 Connection to solid wall – N W118.de-VM200 Board joint – NHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-B200 Board joint – N W118.de-VU200 Connection to floor on basic floor – NHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Uniflott + Trenn-Fix
Trennwandkitt acoustical sealante.g. Knauf Drehstiftdübel nailable plugs
Connect the CW stud to the UW runnerwith steel blind rivets
12.5 mm Diamant1x galvanized sheet metal ≥ 0.5 mm thick25 mm Solid Board
Diamant Screw XTN CW stud
1x galvanized sheet metal≥ 0.5 mm thick
Drywall Screw TNe.g. Knauf Drehstiftdübel nailable plug
Diamant Screw XTN
Drywall Screw TN
UniflottCW stud
12.5 mm Diamant
25 mm Solid Board1x galvanized sheet metal ≥ 0.5 mmthick, joint overlap ≥ 100 mm
1x galvanized sheet metal ≥ 0.5 mmthick, joint overlap ≥ 100 mm
Diamant Screw XTN25 mm Solid Board
12.5 mmDiamant
Uniflott Connect the CW stud to the UW runnerwith steel blind rivets
UW runner
Uniflott
e.g. Knauf Drehstiftdübel nailable plugs
Connect the CW stud to the UW runnerwith steel blind rivets
12.5 mm Diamant1x galvanized sheet metal ≥ 0.5 mm thick25 mm Solid Board
W11
9.de
W11
8.de
24 W11RC.de Knauf Burglar-Retardant Partitions
Single metal stud frame – Solid Board+ Diamant + sheet metal insert
Construction detailsW118.de Security Wall N – With sheet metal insert
W118.de-A201 Connection to metal stud partition – N W118.de-D200 Corner – NHorizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-BFU200 Movement joint – N W118.de-VO201 Connection to ceiling – deflection head – N 1)
Horizontal section I Without fire resistance Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
CW studUW runner
Diamant Screw XTN
12.5 mm Diamant
25 mm Solid Board
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mmAcoustical
sealant Uniflott
1x galvanized sheet metal≥ 0.5 mm thick
Sheet steel if required
If necessarycorner trim oredge trim Dallas 90°
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
12.5 mm Diamant
25 mm Solid BoardCW stud
1x galvanized sheet metal≥ 0.5 mm thick
Diamant Screw XTNDrywall Screw TN
a20a≥
Drywall Screw TB
20≥Diamant Screw
XTNCW stud
UW runnera ≤ 20 mmEdge Trim,
if required
1x galvanized sheet metal≥ 0.5 mm thick
25 mm Solid Board
12.5 mm Diamant ab
+ 5a Fastener suitable for the substrate
Ø ≥ 6 mm; a ≤ 500 mm; fixed withoffset, install according tocertification or double setting depth
Knauf angle profile 50/35/0.7
Permanently elastic seale.g. Knauf Insulation LDS Solimur
Knauf board strips(height dependent on theceiling deflection)
≥ 20
a
Do notscrew
fasten tothe UWrunner
≥ 20 e.g. Knauf design
element
UW runner
Dimensions in mm I Scale 1:5
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 30 ≥ 10 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 13)Influence of a deflection head on the sound reduction index
■ W118.de Overall -3 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not rivet the profiles. Do not screw fasten the boards to the UW runners.
■ See also Knauf YouTube Channel
W11
9.de
W11
8.de
25W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5
Construction detailsW118.de Security Wall RC2 – lead free
W118.de-P400 Board layer 1 horizontal, board layer 2 vertical W118.de-VO400 Connection to ceiling on basic ceiling – RC225 mm Solid Board + 12.5 mm Diamant Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-A400 Connection to solid wall – RC2 W118.de-VM400 Board joint – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-B400 Board joint – RC2 W118.de-VU400 Connection to floor on basic floor – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Trennwandkittacoustical sealant
Uniflott + Trenn-Fix
CW stud25 mm Solid Board12.5 mm Diamant
e.g. Knauf Drehstiftdübelnailable plug
25 mm Solid Board12.5 mm Diamant
CW stud
Diamant Screw XTNDrywall Screw TN
e.g. Knauf Drehstiftdübel nailable plug
Uniflott + Trenn-Fix
UniflottDiamant Screw XTNCW stud25 mm Solid Board12.5 mm Diamant
UniflottCW stud
Diamant Screw XTN
25 mm Solid Board
UW runner
12.5 mm Diamant
Drywall Screw TN
Diamant Screw XTNUniflott
UW runnerCW stud
12.5 mm Diamant25 mm Solid Board
e.g. Knauf Drehstiftdübelnailable plug
Single metal stud frame – Solid Board + Diamant
Note Screw spacing 1st layer Solid Board ≤ 200 mm Drywall Screws TN, 2nd layer Diamant ≤ 250 mm Diamant Screws XTN.
W11
9.de
W11
8.de
26 W11RC.de Knauf Burglar-Retardant Partitions
Construction detailsW118.de Security Wall RC2 – lead free
Single metal stud frame – Solid Board + DiamantW118.de-A401 Connection to metal stud partition – RC2 W118.de-D400 Corner – RC2Horizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-BFU400 Control joint – RC2 W118.de-BFU401 Control joint – RC2Horizontal section Horizontal section
■ Knauf recommendation for partition cavity 50 mm. ■ The rigid connection of the wall shells causes a local reduction of the sound insulation.
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
CW studUW runner
Diamant Screw XTN
12.5 mm Diamant25 mm Solid Board
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
12.5 mm Diamant 25 mm Solid Board
Acousticalsealant Uniflott
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
12.5 mm Diamant25 mm Solid Board
CW stud
If necessary,corner trim oredge trim Dallas 90°
UW runnerCW stud
Uniflott
DiamantScrew XTN
12.5 mmDiamant
25 mm SolidBoard
a20a20a≥≥ a ≤ 20 mm
≤ 200
Diamant ScrewXTN; a ≤ 500 mm
Metal Screw LN 3.5 x 11; a ≤ 250 mm
CW 50 stud
Profile CW 75
Drywall ScrewTN 4.5 x 70
12.5 mm Diamant strips 25 mm Solid Board12.5 mm DiamantInsulation layer as required
a20a20a≥≥
a ≤ 20 mm
≤ 200
Diamant-Screw XTN
DrywallScrew TN
2x 25 mm Solid Board;glued and fixed with Knauf "Gypsum Board on Board" screw; a ≤ 250 mm
12.5 mm Diamant25 mm Solid
BoardUW 50 runner
Dimensions in mm I Scale 1:5
Note Screw spacing 1st layer Solid Board ≤ 200 mm Drywall Screws TN, 2nd layer Diamant ≤ 250 mm Diamant Screws XTN.
W11
9.de
W11
8.de
27W11RC.de Knauf Burglar-Retardant Partitions
W118.de-VO401 Connection to ceiling, deflection head – RC2 1)
Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 20 ≥ 20 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 13)Influence of a deflection head on the sound reduction index
■ W118.de Overall -3 dB
Notes
■ Screw spacing 1st layer Solid Board ≤ 200 mm Drywall Screws TN, 2nd layer Diamant ≤ 250 mm Diamant Screws XTN.
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not screw fasten the boards to the UW runner.
■ See also Knauf YouTube Channel
a + 5
aa
b≥
20
UW runnerCW stud
25 mm Solid Board12.5 mm Diamant
Knauf joint fillerKnauf board strips(height dependent on the ceilingdeflection)
Permanently elastic seal,e.g. Knauf Insulation LDS Solimur
Fasteners suitable for the substrate;a ≤ 250 mm
Do not screw onto theUW runner
W118.de-ELT400 Power socket installation – RC2Horizontal section I Without fire resistance
68
71
Stud spacing 625 mm
■ Openings may be installed at any position between the studs, except not directly opposite one another.
■ With fire protection requirements see page 57.
Penetrations Scheme DrawingsView I Without fire resistance
250 mm
250 m
m
Built-in
Minimum of 3 screwsper profile
Surround withCW studs
Single metal stud frame – Solid Board + Diamant
Construction detailsW118.de Security Wall RC2 – lead free
Dimensions in mm I Scale 1:5
W11
9.de
W11
8.de
28 W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5Single metal stud frame – Diamant Steel GKFI + DiamantW118.de-P500 Vertical board layers W118.de-VO500 Connection to ceiling on basic ceiling – RC2Diamant Steel GKFI 12.5 + 0.4 + 12.5 mm Diamant Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-A500 Connection to solid wall – RC2 W118.de-VM500 Board joint – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-B500 Board joint – RC2 W118.de-VU500 Connection to floor on basic floor – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
12.5 mm DiamantDiamant Steel GKFI 12.5 + 0.4CW stud
Uniflott + TrennfixTrennwandkitt acoustical sealante.g. Knauf Drehstiftdübelnailable plugs
Diamant Screw XTBTrennwandkitt acoustical sealant
Uniflott + Trenn-Fix
CW stud12.5 mm Diamant
Diamant Steel GKFI 12.5 + 0.4
e.g. Knauf Drehstiftdübel nailable plugs
UniflottDiamant Screw XTBCW studDiamant Steel GKFI 12.5 + 0.412.5 mm Diamant
UniflottCW stud
UW runner
Diamant Screw XTB
Diamant Steel GKFI 12.5 + 0.412.5 mm Diamant 12.5 mm Diamant
Diamant Steel GKFI 12.5 + 0.4CW studUW runner
Diamant Screw XTBUniflott
e.g. Knauf Drehstiftdübelnailable plug
Construction detailsW118.de Security wall RC2 – With Diamant Steel GKFI
W11
9.de
W11
8.de
29W11RC.de Knauf Burglar-Retardant Partitions
Single metal stud frame – Diamant Steel GKFI + Diamant
Construction detailsW118.de Security wall RC2 – With Diamant Steel GKFI
W118.de-A501 Connection to metal stud partition – RC2 W118.de-D500 Corner – RC2Horizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-BFU500 Control joint – RC2 W118.de-BFU501 Control joint – RC2Horizontal section Horizontal section
a20a20a a ≤ 20 mm≥≥
≤ 200
12.5 mm DiamantDiamant Steel
GKFI 12.5 + 0.4UW 50 runner
2x Diamant Steel GKFI 12.5 + 0.4+ 2x 12.5 mm Diamant; glued andfixed with Diamant Screws XTB;a ≤ 500 mm
DiamantScrew XTB
■ Knauf recommendation for partition cavity 50 mm. ■ The rigid connection of the wall shells causes a local reduction of the sound insulation.
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Diamant Screw XTB
12.5 mm DiamantDiamant Steel GKFI 12.5 + 0.4
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mmUniflott
CW studUW runner
Acousticalsealant
12.5 mm Diamant Diamant Steel GKFI 12.5 + 0.4
Diamant ScrewXTB
Uniflott
Diamant SteelGKFI 12.5 + 0.412.5 mm Diamant
Diamant SteelGKFI 12.5 + 0.4
12.5 mm Diamant
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
CW studUW runner
If necessary,corner trim oredge trim Dallas 90°
CW stud
Diamant Screw XTB
a20 a ≤ 20 mm≥
a20a≥
≤ 200
CW 75 studMetal Screw LN 3.5 x 11;a ≤ 250 mm
CW 50 studDiamant Steel GKFI12.5 + 0.4 strips
Diamant ScrewsXTB
Insulation layer as requiredEdge trim if required
Diamant Steel GKFI 12.5 + 0.412.5 mm Diamant
Dimensions in mm I Scale 1:5
W11
9.de
W11
8.de
30 W11RC.de Knauf Burglar-Retardant Partitions
Single metal stud frame – Diamant Steel GKFI + DiamantW118.de-VO501 Connection to ceiling, deflection head – RC2 1)
Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 20 ≥ 20 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 13)Influence of a deflection head on the sound reduction index
■ W118.de Overall -3 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not screw fasten the boards to the UW runner.
■ See also Knauf YouTube Channel
+ 5
a≥
20a
Diamant Steel GKFI 12.5 + 0.412.5 mm Diamant
UW runnerCW stud
Knauf joint fillerKnauf board strips(height dependent on ceilingdeflection)
Permanently elastic seale.g. Knauf Insulation LDS Solimur
Fastener suitable for the substrate;a ≤ 250 mm
Do not screw onto theUW runner
ab
Construction detailsW118.de Security wall RC2 – With Diamant Steel GKFI
Dimensions in mm I Scale 1:5
W118.de-ELT500 Power socket installation – RC2Horizontal section I Without fire resistance
Stud spacing 625 mm
68
71
■ Openings may be installed at any position between the studs, except not directly opposite one another.
■ With fire protection requirements see page 57.
Penetrations Scheme DrawingsView I Without fire resistance
250 mm
250 m
m
Built-in
Minimum of 3 screwsper profile
Surround withCW studs
W11
9.de
W11
8.de
31W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5Single metal stud frame – 2x Diamant + sheet metal inserts
Construction detailsW118.de Security Wall A – With sheet metal inserts
W118.de-P300 Vertical board layers W118.de-VO300 Connection to ceiling on basic ceiling – A2x 12.5 mm Diamant + 2x 0.5 mm sheet metal inserts Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-A300 Connection to solid wall – A W118.de-VM300 Board joint – AHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-B300 Board joint – A W118.de-VU300 Connection to floor on basic floor – AHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Uniflott + Trenn-FixTrennwandkitt acoustical sealantConnect the CW stud to theUW runner with steel blind rivetse.g. Knauf Drehstiftdübel nailable plug2x galvanized sheet metal≥ 0.5 mm thick2x 12.5 mm Diamant
e.g. Knauf Drehstiftdübel nailable plug
Acoustical sealantCW stud
2x galvanized sheet metal ≥ 0.5 mm thick
Uniflott + Trenn-Fix
Diamant Screw XTN
CW stud
Uniflott
2x 12.5 mm Diamant2x galvanized sheet metal≥ 0.5 mm thick,joint overlap ≥ 100 mm
Uniflott
2x galvanized sheet metal ≥ 0.5 mm thick,joint overlap ≥ 100 mm
Connect the CW stud to theUW runner with steel blind rivets
2x 12.5 mmDiamant
Uniflott
Connect the CW stud to the UWrunner with steel blind rivets
e.g. Knauf Drehstiftdübelnailable plug
CW stud
2x galvanized sheet metal≥ 0.5 mm thick
2x 12.5 mm DiamantW
119.d
eW
118.d
e
32 W11RC.de Knauf Burglar-Retardant Partitions
Single metal stud frame – 2x Diamant + sheet metal inserts
Construction detailsW118.de Security Wall A – With sheet metal inserts
W118.de-A301 Connection to metal stud partition – A W118.de-D300 Corner – AHorizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-BFU301 Movement joint – A W118.de-VO301 Connection to ceiling, deflection head – A 1)
Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
CW stud
UW runner
2x galvanized sheetmetal ≥ 0.5 mm thick
2x galvanized sheetmetal ≥ 0.5 mm thick
Diamant Screw XTN
2x 12.5 mm DiamantKnauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
Trennwandkittacoustical sealant
Uniflott
Sheet metal if required
2xgalvanized
sheet metal≥ 0.5 mm
thickUniflott
2x galvanized sheet metal≥ 0.5 mm thick
2x 12.5 mm Diamant
If necessary,corner trim oredge trim Dallas 90°
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
Diamant Screw XTNCW stud
CW stud
a ≤ 20 mm
2x galvanized sheetmetal ≥ 0.5 mm thick
Diamant Screw XTB
UW runner
DiamantScrew XTN
≤ 200
CW studUW runner
UA profile
Metal Screw LB 3.5 x 9.5;a ≤ 250 mm
2x 12.5 mmDiamant
aaa 20≥
20≥
Edge trim if required
≥ 20
ab
a+
5a
Knauf board strips(height dependent on theceiling deflection)
Fastener suitable for the substrateØ ≥ 6 mm; a ≤ 500 mm; fixed withoffset, install according tocertification or double setting depth
Knauf angle profile 50/35/0.7
Permanently elastic seale.g. Knauf Insulation LDS Solimur
Do notscrew
fasten tothe UWrunner
≥ 20 e.g. Knauf design element
UW runner
Dimensions in mm I Scale 1:5
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 30 ≥ 10 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 15)Influence of a deflection head on the sound reduction index
■ W118.de Overall -3 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not rivet the profiles. Do not screw fasten the boards to the UW runners.
■ See also Knauf YouTube Channel
W11
9.de
W11
8.de
33W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5Single metal stud frame – 3x Diamant + sheet metal inserts
Construction detailsW118.de Security Wall A – With sheet metal inserts
W118.de-P700 Vertical board layers W118.de-VO700 Connection to ceiling on basic ceiling – A3x 12.5 mm Diamant + 2x 0.5 mm sheet metal inserts Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-A700 Connection to solid wall – A W118.de-VM700 Board joint – AHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-B700 Board joint – A W118.de-VU700 Connection to floor on basic floor – AHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Uniflott + Trenn-FixTrennwandkitt acoustical sealantConnect the CW stud to the UW runner with steel blind rivetse.g. Knauf Drehstiftdübel nailable plugs3x 12.5 mm Diamant2x galvanized sheet metal≥ 0.5 mm thick
CW studUW runner
e.g. Knauf Drehstiftdübel nailable plugsTrennwandkitt acoustical sealant
Uniflott + Trenn-Fix
CW studDiamant Screw XTNUniflott
3x 12.5 mm Diamant2x galvanized sheet metal≥ 0.5 mm thick,joint overlap ≥ 100 mm
2x galvanized sheet metal ≥ 0.5 mm thick,joint overlap ≥ 100 mm
3x 12.5 mm Diamant
Diamant Screw XTN
Connect the CW stud to the UW runnerwith steel blind rivets
Connect the CW stud to theUW runner with steel blindrivetsUniflott
3x 12.5 mm Diamante.g. Knauf Drehstiftdübelnailable plugs
2x galvanized sheet metal≥ 0.5 mm thick
W11
9.de
W11
8.de
34 W11RC.de Knauf Burglar-Retardant Partitions
Single metal stud frame – 3x Diamant + sheet metal inserts
Construction detailsW118.de Security Wall A – With sheet metal inserts
W118.de-A701 Connection to metal stud partition – A W118.de-D700 Corner – AHorizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-BFU700 Movement joint – A W118.de-VO701 Connection to ceiling, deflection head – A 1)
Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
2x galvanized sheetmetal ≥ 0.5 mm dick
CW studUW runner
Trennwandkittacoustical sealant
2x galvanized sheetmetal ≥ 0.5 mm thick3x 12.5 mm Diamant
Diamant Screw XTN
Sheet metal if required
Uniflott
2x galvanizedsheet metal≥ 0.5 mm
thick
3x 12.5 mmDiamant
Uniflott
If necessary,corner trim oredge trim Dallas 90°
2x galvanized sheet metal≥ 0.5 mm thick
Diamant Screw XTNCW stud
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
3x 12.5 mm Diamant
CW stud
a20a20a≥≥
2x galvanized sheet metal≥ 0.5 mm thick
Diamant Screw XTB 3x 12.5 mm Diamant
20≥ CW stud
UW runnerUA profileDiamant
Screw XTN a ≤ 20 mm
Knauf angle profile 50/35/0.7
Fastener suitable for the substrateØ ≥ 6 mm; a ≤ 500 mm; fixed withoffset, install according tocertification or double settingdepth
≥ 20
ab
a+
5a
Permanently elastic seale.g. Knauf Insulation LDS Solimur
e.g. Knauf Designelement
UW runnerDo notscrew
fasten tothe UWrunner
≥ 20
Knauf board strips(height dependent on theceiling deflection)
Dimensions in mm I Scale 1:5
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 30 ≥ 10 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 15)Influence of a deflection head on the sound reduction index
■ W118.de Overall -3 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not rivet the profiles. Do not screw fasten the boards to the UW runners.
■ See also Knauf YouTube Channel
W11
9.de
W11
8.de
35W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5Single metal stud frame – 2x Diamant Steel GKFI
Construction detailsW118.de Security wall RC3 – With Diamant Steel GKFI
W118.de-P600 Vertical board layers W118.de-VO600 Connection to ceiling on basic ceiling – RC32x Diamant Steel GKFI 12.5 + 0.4 Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-A600 Connection to solid wall – RC3 W118.de-VM600 Board joint – RC3Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-B600 Board joint – RC3 W118.de-VU600 Connection to floor on basic floor – RC3Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Trennwandkitt acoustical sealant
Uniflott + Trenn-FixDiamant Screw XTB
CW stud2x Diamant Steel GKFI12.5 + 0.4
e.g. Knauf Drehstiftdübelnailable plugs
UW runner
Diamant Screw XTBTrennwandkitt acoustical sealant
Uniflott + Trenn-Fix
2x Diamant Steel GKFI 12.5 + 0.4CW stud
e.g. Knauf Drehstiftdübel nailable plugs
UniflottDiamant Screw XTBCW stud2x Diamant Steel GKFI 12.5 + 0.4
UniflottCW stud
UW runner
Diamant Screw XTB2x Diamant Steel GKFI 12.5 + 0.4 2x Diamant Steel
GKFI 12.5 + 0.4CW studUW runner
Diamant Screw XTBUniflott
e.g. Knauf Drehstiftdübelnailable plug
W11
9.de
W11
8.de
36 W11RC.de Knauf Burglar-Retardant Partitions
Single metal stud frame – 2x Diamant Steel GKFI
Construction detailsW118.de Security wall RC3 – With Diamant Steel GKFI
W118.de-A601 Connection to metal stud partition – RC3 W118.de-D600 Corner – RC3Horizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W118.de-BFU600 Control joint – RC3 W118.de-BFU601 Control joint – RC3Horizontal section Horizontal section
■ Knauf recommendation for partition cavity 50 mm. ■ The rigid connection of the wall shells causes a local reduction of the sound insulation.
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
2x Diamant Steel GKFI 12.5 + 0.4
CW stud
UW runner
Trennwandkittacoustical
sealant
Diamant Screw XTBUniflott
2x Diamant SteelGKFI 12.5 + 0.4
If necessary,corner trim oredge trim Dallas 90°
2x Diamant SteelGKFI 12.5 + 0.4
Diamant ScrewXTB
Uniflott
CW stud
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
CW stud
2x Diamant SteelGKFI 12.5 + 0.4
UW runner
a20
a ≤ 20 mm
≥a20a
≥
≤ 200
Edge trim if requiredDiamant Steel GKFI
12.5 + 0.4 strips
Insulation layer if requiredCW 50 stud
Metal screw LN 3.5 x 11;a ≤ 250 mm
CW 75 stud 2x Diamant SteelGKFI 12.5 + 0.4Diamant Screw XTB
a20a20a≥≥
a ≤ 20 mm
≤ 200
2x Diamant SteelGKFI 12.5 + 0.4
UW 50 runner
DiamantScrew XTB
2x Diamant Steel GKFI 12.5 + 0.4+ 2x 12.5 mm Diamant; glued andfixed with Diamant Screws XTB;a ≤ 500 mm
Dimensions in mm I Scale 1:5
W11
9.de
W11
8.de
37W11RC.de Knauf Burglar-Retardant Partitions
Construction detailsW118.de Security wall RC3 – With Diamant Steel GKFI
W118.de-VO601 Connection to ceiling, deflection head – RC3 1)
Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 20 ≥ 20 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 15)Influence of a deflection head on the sound reduction index
■ W118.de Overall -3 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not screw fasten the boards to the UW runner.
■ See also Knauf YouTube Channel
+ 5
a≥
20a
Knauf joint fillerKnauf board strips(height dependent on ceilingdeflection)
Permanently elastic seale.g. Knauf Insulation LDS Solimur
Fastener suitable for the substrate;a ≤ 250 mm
Do not screw onto theUW runner2x Diamant Steel GKFI 12.5 + 0.4
UW runnerCW stud
ab
Single metal stud frame – 2x Diamant Steel GKFI Dimensions in mm I Scale 1:5
W118.de-ELT600 Power socket installation – RC3Horizontal section I Without fire resistance
68
71
Stud spacing 625 mm
■ Openings may be installed at any position between the studs, except not directly opposite one another.
■ With fire protection requirements see page 57.
W11
8.de
W11
9.de
38 W11RC.de Knauf Burglar-Retardant Partitions
Decoupled double stud frame – 2x Diamant + sheet metal insert
Construction detailsW119.de Security Wall N – With sheet metal insert
W119.de-P1 Vertical board layers W119.de-VO1 Connection to ceiling on basic ceiling – N2x 12.5 mm Diamant + 1x 0.5 mm sheet metal insert Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-A1 Connection to solid wall – N W119.de-VM1 Board joint – NHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-B1 Board joint – N W119.de-VU1 Connection to floor on basic floor – NHorizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Diamant Screw XTNUniflott
CW stud2x 12.5 mm Diamant1x galvanized sheet metal≥ 0.5 mm thick,joint overlap ≥ 100 mm
Self-adhesiveinsulation strip;a ≤ 500 mm
CW stud
Uniflott + Trenn-FixTrennwandkitt acoustical sealant
e.g. Knauf Drehstiftdübelnailable plugs
Diamant Screw XTNUniflott
CW stud2x 12.5 mm Diamant1x galvanized sheet metal≥ 0.5 mm thick,joint overlap ≥ 100 mm
Self-adhesiveinsulation strip;a ≤ 500 mm
Uniflott
1x galvanized sheet metal ≥ 0.5 mmthick, joint overlap ≥ 100 mm
2x 12.5 mm Diamant
Diamant Screw XTN
UW runner
Uniflotte.g. Knauf Drehstiftdübel nailable plug
Connect the CW stud to the UWrunner with steel blind rivets
1x galvanized sheet metal≥ 0.5 mm thick2x 12.5 mm DiamantSelf-adhesive insulation strip;a ≤ 500 mm
Scale 1:5
W11
9.de
W11
8.de
39W11RC.de Knauf Burglar-Retardant Partitions
Decoupled double stud frame – 2x Diamant + sheet metal insert
Construction detailsW119.de Security Wall N – With sheet metal insert
W119.de-A2 Connection to metal stud partition – N W119.de-D1 Corner – NHorizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-BFU1 Movement joint – N W119.de-VO2 Connection to ceiling, deflection head – N 1)
Horizontal section I Without fire resistance Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1x galvanized sheetmetal ≥ 0.5 mm thick
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm1x galvanized sheet metal≥ 0.5 mm dick
CWstud
UWrunner
Acousticalsealant
2x 12.5 mm Diamant
Sheet metal if required
Uniflott
1xgalvanized
sheet metal≥ 0.5 mm
thick
2x 12.5 mm Diamant1x galvanized sheet metal ≥ 0.5 mm thickKnauf Multi-Purpose Screw FN 4.3 x 65; a ≤ 250 mm
Self-adhesiveinsulation material stripDiamant Screw XTNCW stud
If necessary,corner trim or edgetrim Dallas 90°
a20a≥
20≥
a ≤ 20 mm
CW studUW runner
UA profile
DiamantScrew XTN
Diamant Screw XTB1x galvanized sheet metal≥ 0.5 mm thick
2x 12.5 mm Diamant
≥ 20
ab
a+
5a
Knauf board strips(height dependent on theceiling deflection)
Fastener suitable for the substrateØ ≥ 6 mm; a ≤ 500 mm; fixed withoffset, install according tocertification or double setting depth
Knauf angle profile 50/35/0.7
Permanently elastic seale.g. Knauf Insulation LDS Solimur
Do notscrew
fasten tothe UWrunner
≥ 20 e.g. Knauf Design
element
UW runner
Dimensions in mm I Scale 1:5
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 30 ≥ 10 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 17)Influence of a deflection head on the sound reduction index
■ W119.de Overall -4 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not rivet the profiles. Do not screw fasten the boards to the UW runners.
■ See also Knauf YouTube Channel
W11
8.de
W11
9.de
40 W11RC.de Knauf Burglar-Retardant Partitions
Double metal stud frame – Solid Board + Diamant
Construction detailsW119.de Security Wall RC2 – lead free
W119.de-P100 Board layer 1 horizontal, board layer 2 vertical W119.de-VO100 Connection to ceiling on basic ceiling – RC225 mm Solid Board + 12.5 mm Diamant Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-A100 Connection to solid wall – RC2 W119.de-VM100 Board joint – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-B100 Board joint – RC2 W119.de-VU100 Connection to floor on basic floor – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Uniflott + Trenn-FixTrennwandkitt acoustical sealante.g. Knauf Drehstiftdübel nailable plugs
CW studSelf-adhesive insulation material strip, a ≤ 500 mm25 mm Solid Board12.5 mm Diamant
25 mm Solid Board12.5 mm DiamantCW stud
Uniflott + Trenn-Fix
Diamant Screw XTNDrywall Screw TN
e.g. Knauf Drehstiftdübel nailable plug
Self-adhesiveinsulation material strip;a ≤ 500 mmUniflottDiamant Screw XTNCW stud25 mm Solid Board12.5 mm Diamant
DiamantScrew
XTN 25 mm Solid Board12.5 mm Diamant
Drywall Screw TN
Uniflott CW stud UW runner
12.5 mm DiamantSelf-adhesive insulation materialstrip; a ≤ 500 mm
Diamant Screw XTNUniflott
UW runner
25 mm Solid Board
e.g. Knauf Drehstiftdübelnailable plug
Note Screw spacing 1st layer Solid Board ≤ 200 mm Drywall Screws TN, 2nd layer Diamant ≤ 250 mm Diamant Screws XTN.
Scale 1:5
W11
8.de
W11
9.de
41W11RC.de Knauf Burglar-Retardant Partitions
Double metal stud frame – Solid Board + Diamant
Construction detailsW119.de Security Wall RC2 – lead free
Note Screw spacing 1st layer Solid Board ≤ 200 mm Drywall Screws TN, 2nd layer Diamant ≤ 250 mm Diamant Screws XTN.
W119.de-A101 Connection to metal stud partition – RC2 W119.de-D100 Corner – RC2Horizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-BFU100 Control joint – RC2Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
12.5 mm Diamant25 mm Solid Board
Diamant Screw XTN
12.5 mm Diamant25 mm Solid Board
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mmUniflott
25 mm Solid Board12.5 mm DiamantKnauf Multi-Purpose Screw FN 4.3 x 65; a ≤ 250 mmSelf-adhesiveinsulation material stripUW runnerCW studDiamant Screw XTN Drywall Screw TNCW stud
If necessary,corner trim oredge trim Dallas 90°
CW stud
Drywall ScrewTN 4.5 x 70
12.5 mm Diamant
Metal Screw LN 3.5 x 11;a ≤ 250 mmUD profile
a20aa≥
≤ 200Diamant Screw XTN; a ≤ 500 mm
CW studSelf-adhesive insulation material strip
20≥
a ≤ 20 mm
Insulation layerif required
25 mm Solid Board
12.5 mm Diamant strip
Scale 1:5
W11
8.de
W11
9.de
42 W11RC.de Knauf Burglar-Retardant Partitions
Construction detailsW119.de Security Wall RC2 – lead free
W119.de-VO101 Connection to ceiling, deflection head – RC2 1)
Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 20 ≥ 20 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 17)Influence of a deflection head on the sound reduction index
■ W119.de Overall -4 dB
Notes
■ Screw spacing 1st layer Solid Board ≤ 200 mm Drywall Screws TN, 2nd layer Diamant ≤ 250 mm Diamant Screws XTN.
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not screw fasten the boards to the UW runner.
■ See also Knauf YouTube Channel
+ 5
aa
≥ 20
a
Knauf filler materialKnauf board strips(height dependent on theceiling deflection)
Self-adhesive insulationmaterial strip; a ≤ 500 mm
Fastener suitable for thesubstrate; a ≤ 250 mm
Permanently elastic seale.g. Knauf Insulation LDSSolimur
b
UW runnerDo notscrew
fasten to theUW runner
Double metal stud frame – Solid Board + Diamant Dimensions in mm I Scale 1:5
W119.de-ELT100 Power socket installation – RC2Horizontal section I Without fire resistance
68
71
Stud spacing 625 mm
■ Openings may be installed at any position between the studs, except not directly opposite one another.
■ With fire protection requirements see page 57.
Penetrations Scheme DrawingsView I Without fire resistance
250 mm
250 m
m
Built-in
Minimum of 3 screwsper profile
Surround withCW studs
W11
8.de
W11
9.de
43W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5Decoupled double metal stud frame – Diamant Steel GKFI + Diamant
Construction detailsW119.de Security wall RC2 – With Diamant Steel GKFI
W119.de-P200 Vertical board layers W119.de-VO200 Connection to ceiling on basic ceiling – RC2Diamant Steel GKFI 12.5 + 0.4 + 12.5 mm Diamant Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-A200 Connection to solid wall – RC2 W119.de-VM200 Board joint – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-B200 Board joint – RC2 W119.de-VU200 Connection to floor on basic floor – RC2Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Trennwandkitt acoustical sealantUniflott + Trenn-Fix
CW studDiamant Steel GKFI 12.5 + 0.412.5 mm Diamant
Self-adhesive insulationmaterial strip; a ≤ 500 mm
e.g. Knauf Drehstiftdübelnailable plug
CW stud 12.5 mm DiamantDiamant Steel GKFI 12.5 + 0.4
Diamant Screw XTBTrennwandkitt acoustical sealant
Uniflott + Trenn-Fix
e.g. Knauf Drehstiftdübel nailable plug
Self-adhesiveinsulation material strip;a ≤ 500 mmUniflottDiamant Screw XTBCW studDiamant Steel GKFI 12.5 + 0.412.5 mm Diamant
Diamant Screw XTB
Diamant Steel GKFI 12.5 + 0.412.5 mm Diamant
Uniflott CW stud UW runner
Self-adhesive insulation materialstrip; a ≤ 500 mm
Diamant Screw XTBUniflott
12.5 mm DiamantDiamant Steel GKFI 12.5 + 0.4
UW runnere.g. Knauf Drehstiftdübel nailable plug
W11
8.de
W11
9.de
44 W11RC.de Knauf Burglar-Retardant Partitions
Decoupled double metal stud frame – Diamant Steel GKFI + Diamant
Construction detailsW119.de Security wall RC2 – With Diamant Steel GKFI
W119.de-A201 Connection to metal stud partition – RC2 W119.de-D200 Corner – RC2Horizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-BFU200 Control joint – RC2Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
12.5 mm DiamantDiamant Steel GKFI 12.5 + 0.4
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mmUniflott
CWstud
UWrunner
Self-adhesive insulation materialstrip; a ≤ 500 mm
Trenn-wandkitt
acousticalsealant
12.5 mm DiamantDiamant Steel GKFI 12.5 + 0.4
Uniflott
Diamant Steel GKFI 12.5 + 0.4 12.5 mm Diamant
Knauf Multi-Purpose Screw FN 4.3 x 65; a ≤ 250 mmSelf-adhesive insulation material stripUW runnerCW stud
Diamant Screw XTB
CW stud
If necessary,corner trim oredge trim Dallas 90°
≤ 200
CW stud
Diamant Steel GKFI12.5 + 0.4 strip
UD runner Metal ScrewLN 3.5 x 11; a ≤ 250 mm
CW stud
Diamant Screws XTB
Self-adhesiveinsulation material strip
a20aa≥
20≥
a ≤ 20 mm
Insulation layeras required
Diamant Steel GKFI 12.5 + 0.412.5 mm Diamant
Dimensions in mm I Scale 1:5
W11
8.de
W11
9.de
45W11RC.de Knauf Burglar-Retardant Partitions
Construction detailsW119.de Security wall RC2 – With Diamant Steel GKFI
W119.de-VO201 Connection to ceiling, deflection head – RC2 1)
Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 20 ≥ 20 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 17)Influence of a deflection head on the sound reduction index
■ W119.de Overall -4 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not screw fasten the boards to the UW runner.
■ See also Knauf YouTube Channel
+ 5
aa
≥ 20
a
Knauf filler materialKnauf board strips(height dependent on theceiling deflection)
Self-adhesive insulationmaterial; a ≤ 500 mm
Fastener suitable for thesubstrate; a ≤ 250 mm
Permanently elastic seale.g. Knauf InsulationLDS SolimurUW runner
b
Do notscrew
fasten tothe UWrunner
Decoupled double metal stud frame – Diamant Steel GKFI + Diamant Dimensions in mm I Scale 1:5W119.de-ELT200 Power socket installation – RC2Horizontal section I Without fire resistance
Stud spacing 625 mm
68
71
■ Openings may be installed at any position between the studs, except not directly opposite one another.
■ With fire protection requirements see page 57.
Penetrations Scheme DrawingsView I Without fire resistance
250 mm
250 m
m
Built-in
Minimum of 3 screwsper profile
Surround withCW studs
W11
8.de
W11
9.de
46 W11RC.de Knauf Burglar-Retardant Partitions
Scale 1:5Decoupled double stud frame – 2x Diamant Steel GKFIW119.de-P300 Vertical board layers W119.de-VO300 Connection to ceiling on basic ceiling – RC32x Diamant Steel GKFI 12.5 + 0.4 Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-A300 Connection to solid wall – RC3 W119.de-VM300 Board joint – RC3Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-B300 Board joint – RC3 W119.de-VU300 Connection to floor on basic floor – RC3Horizontal section Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Trennwandkitt acoustical sealantUniflott + Trenn-Fix
CW stud2x Diamant Steel GKFI12.5 + 0.4
Self-adhesive insulation materialstrip; a ≤ 500 mm
e.g. Knauf Drehstiftdübelnailable plug
2x Diamant Steel GKFI 12.5 + 0.4CW stud
Diamant Screw XTBTrennwandkitt acoustical sealant
Uniflott + Trenn-Fix
e.g. Knauf Drehstiftdübel nailable plugs
Self-adhesiveinsulation material strip;a ≤ 500 mm
Diamant Screw XTBCW stud2x Diamant Steel GKFI 12.5 + 0.4
Uniflott
Diamant Screw XTB2x Diamant Steel GKFI 12.5 + 0.4
Uniflott CW stud UW runner
Self-adhesive insulationmaterial strip; a ≤ 500 mm
Diamant Screw XTBUniflott
CW stud
UW runner
2x Diamant Steel GKFI 12.5 + 0.4
e.g. Knauf Drehstiftdübel nailable plug
Construction detailsW119.de Security wall RC3 – With Diamant Steel GKFI
W11
8.de
W11
9.de
47W11RC.de Knauf Burglar-Retardant Partitions
Decoupled double stud frame – 2x Diamant Steel GKFI
Construction detailsW119.de Security wall RC3 – With Diamant Steel GKFI
W119.de-A301 Connection to metal stud partition – RC3 W119.de-D300 Corner – RC3Horizontal section Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
W119.de-BFU300 Control joint – RC3Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
CWstud
UWrunner Diamant Steel GKFI 12.5 + 0.4
Self-adhesive insulation material strip; a ≤ 500 mmKnauf Multi-Purpose Screw FN 4.3 x 65; a ≤ 250 mmUniflott
Trennwandkittacoustical sealant
2x Diamant Steel GKFI 12.5 + 0.4
UW runnerCW stud
Knauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 250 mm
2x Diamant SteelGKFI 12.5 + 0.4
If necessary,corner trim oredge trim Dallas 90°
CW stud
Uniflott
Self-adhesive insulationmaterial strip
≤ 200 a ≤ 20 mm
CW stud
Edge trim if necessary
Diamant Steel GKFI12.5 + 0.4 strip
UD runner Metal Screw LN 3.5 x 11;a ≤ 250 mm
CW stud
Diamant ScrewsXTB
Self-adhesive insulationmaterial strip
a20aa≥
20≥Insulation layer
if required
2x Diamant Steel GKFI12.5 + 0.4
Dimensions in mm I Scale 1:5
W11
8.de
W11
9.de
48 W11RC.de Knauf Burglar-Retardant Partitions
Decoupled double stud frame – 2x Diamant Steel GKFI
Construction detailsW119.de Security wall RC3 – With Diamant Steel GKFI
Dimensions in mm I Scale 1:5
W119.de-VO301 Connection to ceiling, deflection head – RC3 1)
Vertical section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
1) Details for deflection heads
WithoutFire resistance
WithFire resistance
Maximum permissible partition height
amm
bmm
amm
bmm m
≤ 20 ≥ 20 ≤ 20 ≥ 20 6.50
■ Observe the permissible partition heights of the system (see page 19)Influence of a deflection head on the sound reduction index
■ W119.de Overall -4 dB
Notes
■ Apply a deflection head in case of ceiling deflection ≥ 10 mm.
■ Larger ceiling deflections / larger partition heights on request.
■ In case of a deflection head, do not screw fasten the boards to the UW runner.
■ See also Knauf YouTube Channel
+ 5
aa
b≥
20a
UW runner
Knauf filler materialKnauf board strips(height dependent on theceiling deflection)
Self-adhesive insulationmaterial strip; a ≤ 500 mm
Fastener suitable for thesubstrate; a ≤ 250 mm
Permanently elastic seale.g. Knauf InsulationLDS Solimur
Do notscrew fasten
to the UWrunner
W119.de-ELT300 Power socket installation – RC3Horizontal section I Without fire resistance
Stud spacing 625 mm
68
71
■ Openings may be installed at any position, except not directly opposite one another.
■ With fire protection requirements see page 57.
W11
8.de
W11
9.de
49W11RC.de Knauf Burglar-Retardant Partitions
Special versionsSingle side installation
Single side installationIn existing structures it may be necessary to upgrade existing walls, which do not feature a burglar-retardant classification or whose classification is insufficient with a Knauf W118.de burglar-retardant partition RC2. For the purpose, an auxiliary construction made of stud profiles is erected before the existing wall on which the cladding layers facing away from the room are attached. Subsequent further construction design is implemented in accordance with the respective system specifications and taking the following details into consideration.
Detail Scale 1:5W118.de-SO600 Single side installation before an existing wall – RC3Horizontal section
Extension of the fire resistance Proof of Usability Prior consultation in acc. to page 6 recommended
DiamantScrew XTB
2x Diamant SteelGKFI 12.5 + 0.4
CW stud
UW runnerKnauf Multi-Purpose ScrewFN 4.3 x 65; a ≤ 500 mmwith washerØ ≥ 30 mm, t = 1.5 to 3.0 mm
2x Diamant Steel GKFI 12.5 + 0.4CW stud as anauxiliary construction
W11
9.de
W11
8.de
50 W11RC.de Knauf Burglar-Retardant Partitions
Special versionsDoor openings
Door openingsMaximum door leaf weightsDoor leaf width
UA profileUA 50 UA 75 UA 100 UA 125 UA 150
≤ 885 mm ≤ 50 kg ≤ 75 kg ≤ 100 kg ≤ 125 kg ≤ 150 kg≤ 1010 mm ≤ 50 kg ≤ 75 kg ≤ 100 kg ≤ 125 kg ≤ 150 kg≤ 1260 mm ≤ 40 kg ≤ 60 kg ≤ 80 kg ≤ 100 kg ≤ 120 kg≤ 1510 mm ≤ 35 kg ≤ 50 kg ≤ 65 kg ≤ 80 kg ≤ 95 kg
Stud frame
Door opening profiles – UA profile
■ Remove the plastic strips on the Door Frame Bracket. ■ Alternative: Knauf Connection Angle for UA profiles
When partitions applied with profiles 125 or 150
UA 125 or UA 150 ■ Screw fasten the Door Frame Bracket 100 in the oblong slots top and bottom each with two enclosed carriage bolts using nuts and washers.
■ In case of a deflection head only hand tighten the carriage bolt on the upper Door Frame Bracket.
■ Manufacture the lintel runner using UW profiles.
Scheme drawings
UW runner cut and bent, screw fastened with UA profile
UA profile room height (not jointed)
Knauf Door Frame Bracket "top", Fastening with the enclosed dowels
Knauf Door Frame Bracket "bottom", Fastening with the enclosed dowels
Door openings with deflection headFor a ceiling deflection up to max. 20 mm
Knauf recommendation:Door opening profiles approx. 40 mm shorter than the stud frame profiles; observe additional constructional situation / constraints, e.g. deflection head.
Cladding ■ Arrange the long joints on the door lintel and not along the door opening, rather offset it to the door lintel center.
■ Arrange the horizontal joints on the door lintel and not along the door opening, rather offset it to the door opening center.
■ Cladding above the door lintel < 400 mm is only permissible in case of floor-to-ceiling boards.
e.g. Vertical board layer All dimensions in mm
Cladding
≥ 150 ≥ 150≥
400
≥ 150
≥ 40
0
≥ 20
0 ≥ 150
LegendLower layerUpper layer
Caution Do not apply board joints to door opening profiles.
Scheme drawing
Knauf Door Frame Bracket "top", Fasten e.g. with Knauf Nailable Plugs "L" 8/100
UA profile
Notes
The door must feature the same burglar-retardant classification as the wall and be suitable for the respective burglar-retardant partition system (observe the manufacturer's installation instructions).Door openings may be installed at any position.Fire protection only in conjunction with a corresponding fire protection connection.
W11
9.de
W11
8.de
51W11RC.de Knauf Burglar-Retardant Partitions
DetailsW118.de-E100 Door opening with UA profile – N W118.de-E700 Door opening with UA profile – AWithout fire protection Without fire protection
W119.de-E100 Door opening with UA profiles – RC2 W118.de-E600 Door opening with UA profile – RC3Without fire protection Without fire protection
1x galvanized sheet metal≥ 0.5 mm thick
UA profile preferably room heightDiamant Screw XTB
Door frame bracket
Building openingdimension
Diamant Screw XTBUA profile as a door frame profile
Door frame bracket
Building openingdimension
UA profile as door frame profileDoor frame bracket
Drywall Screw TBDiamant Screw XTB
Building openingdimension
Diamant Screw XTBUA profile as a door frame profile
Door frame bracket
Building openingdimension
Special versionsDoor openings
Horizontal section I Scale 1:5
Notes
The door must feature the same burglar-retardant classification as the wall and be suitable for the respective burglar-retardant partition system (observe the manufacturer's installation instructions).Door openings may be installed at any position.Furthermore, the details of the door manufacturers are to be observed (e.g. fire protection approval, additional constructional measures, etc.)Fire protection only in conjunction with a corresponding fire protection connection.
W11
9.de
W11
8.de
52 W11RC.de Knauf Burglar-Retardant Partitions
Stud frameGeneralApply a suitable sealant to the rear side of runners for the connection to flanking constructional components. Ensure a carefully applied seal for sound insulation requirements analogue to the specifications of the DIN 4109-33:2016-07 section 4.1.1.3 (e.g. Trennwandkitt acoustical sealant) (Recommendation: always with Trennwandkitt acoustical sealant).
Trennwandkittacoustical sealant(with sound insulationrequirements)
Sealing tape
If a deflection of the ceiling ≥ 10 mm can be expected, install deflection heads.Anchor wall perimeter runners to the floor and ceiling. Anchor wall perimeter runners with suitable dowels to flanking walls. Use suitable spacings and fasteners in accordance with the tables of the corresponding systems.Use suitable fasteners
■ Solid flanking constructional components: Knauf Drehstiftdübel nailable plugs with masonry or Knauf Deckennagel ceiling steel dowels with reinforced concrete.
■ Non-solid flanking constructional components: Anchors specially suited for the building material, e.g. Knauf Universalschraube FN Multi-Purpose Screws for metal stud partitions, etc…
Maximum permissible fastener spacings Without fire protection
Supporting fastening perimeter runner (UW) connection to basic floor and basic ceilingPartition height
Knauf Ceiling Steel Dowels (with reinforced concrete)
Knauf Drehstiftdübel nailable plug
Knauf Universalschraube FN Multi-Purpose Screw
m1x 1x 1xmm mm mm
≤ 6.50 500 500 500> 6.50 up to ≤ 12.00
500 – Check the loadbearing capacity of the substrate – select suitable fasteners / anchors (for 2 kN/m)
■ Constructional anchoring of the wall connection profiles (CW) to the flanking walls at centres of 500 mm (min. 3 anchoring points).
■ Fastening of the perimeter runner in the deflection head area with a spacing of 250 mm.
Maximum permissible fastener spacings With fire resistance
Supporting fastening perimeter runner (UW) connection to basic floor and basic ceilingPartition height Knauf Ceiling
Steel Dowels(with rein-forced con-crete)
Knauf Drehstiftdü-bel nailable plug
Knauf Universalschraube FN Multi-Purpose Screw
m1x 1x 1xmm mm mm
≤ 6.50 500 500 500> 6.50 to ≤ 7.00
500 –
Check the loadbearing capacity of the substrate – select suitable fasteners / anchors (for 2 kN/m)
W118.de A Triple-layer> 6.50 to ≤ 9.00
■ Constructional anchoring of the wall connection profiles (CW) to the flanking walls at centres of 500 mm (min. 3 anchoring points).
■ Fastening of the perimeter runner in the deflection head area with a spacing of 250 mm.
Installation and applicationStud frame
W11
9.de
W11
8.de
53W11RC.de Knauf Burglar-Retardant Partitions
Grid (continued)Place the CW studs into the UW runners arranged along the length at the required axial spacing and align them.
■ For burglar-retardant walls acc. to resistance class N / A, connect the profiles at the top and bottom each with 2 steel blind rivets ≥ 3 x 8 mm.
■ In case of a deflection head, do not rivet the profile at the top.
■ Riveting in case of burglar-retardant partitions acc. to resistance class RC2 / RC3 not required.
W118.de Single metal stud frame
Stud spacing a
Knauf CW stud
Knauf UW runner
W119.de Decoupled double stud partition ■ Decoupling of the CW stud by self-adhesive insulation strip pieces on the entire partition height, spacing ≤ 500 mm
≤ 50
0 mm
≤ 50
0 mm
≤ 50
0 mm
Knauf CW stud
Knauf UW runner
Decoupling withinsulation strips
Scheme drawings
Installation and applicationStud frame
W11
9.de
W11
8.de
54 W11RC.de Knauf Burglar-Retardant Partitions
Grid (continued)Knauf recommendation: Use floor-to-ceiling profiles. Profile extensions
■ Stagger the heights of the profile joints (alternating upper and lower wall half).
■ With fire protection requirements a maximum or 2 profile joints per stud is permitted.
Option 12 CW studs interlaced to form a box.
Option 2CW studs butt joint connected, interlaced with additional CW stud
5050
Knauf CW stud 1
Knauf CW stud 2
ü
5050
5050
üü
AdditionalKnauf CW
stud
KnaufCW stud 1
Knauf CWstud 2
Option 32 CW studs or 2 UA profiles butt jointed, connected with additional UW runner
5050
5050
üü
AdditionalKnauf UW runner
Knauf CWstud 1
Knauf CWstud 2
AdditionalKnauf UW runner
Knauf UAprofile 1
Knauf UAprofile 2
5050
5050
üü
Options 1 to 3Rivet, screw fix or, if possible, crimp the profiles in the overlapping area.
Crimping pliers forcrimp connection
Option 4For UA profiles under load e.g. door framing or Sanistand installation2 UA profiles butt joint connected with additional UA profiles at the web side.
üü
AdditionalKnauf UA profile
Knauf UAprofile 1
Knauf UAprofile 2
Screw fasten using 2x per UA profile with M8 carriage bolts or self-tapping screws ≥ Ø 4.5 mm
50 50
50 50 ü
ü
50 50
50 50 ü
ü
Scheme drawings I Dimensions in mm
Extension of the fire resistance Proof of UsabilityPrior consultation is recommended acc. to page 6.
Profile extensionsKnauf profiles Overlap üCW 50 / UA 50 ≥ 500 mmCW 75 / UA 75 ≥ 750 mmCW 100 / UA 100 ≥ 1000 mmCW 125 / UA 125 ≥ 1250 mmCW 150 / UA 150 ≥ 1500 mm
Web cut-out / H punches Web cut-out – on-site
■ Maximum 2 web cut-outs per metal stud (for CW 50 maximum 1 web cut-out)
■ Observe the dimensions in acc. with the drawing ■ Knauf CW studs / UA profiles 50/75/100/125/150 ■ Large number of smaller openings possible on request ■ The openings can be provided in addition to the usual factory made H punches.
■ Additional web cut-outs in the local load introduction area (cantilever loads / beam loads / dynamic loads) are not permissible.
b2x
b
≤ b -20
≤≥
≥b≤
2x b≥ 10
≥ 10
b
2x b≥
≤ b
H punches – factory-madeFor cable penetrations in Knauf CW studs
Insulation layerGeneralDepending on the requirements for fire protection, sound insulation and thermal insulation, secure the insulation against sliding (compress up to approx. 10 mm) and tightly joint in the grid (or if necessary install insulation strips to prevent sliding in the stud profiles). Additional insulation strips for deviation of the insulation material thickness > 20 mm from the stud web width.
≥ 50 mm
Additionalinsulationstrip
Installation and applicationStud frame I Insulation layer
W11
8.de
W11
9.de
55W11RC.de Knauf Burglar-Retardant Partitions
Board layers Board layers vertical
■ Board width: 1250 mm ■ Stud spacing: 625 mm
Long
edge
Front edge
Lower/upper layer: ■ Stagger the long edge joints by at least one stud spacing and arrange on the studs.
■ If floor-to-ceiling boards are not used, stagger the front edge joints ≥ 400 mm in a cladding layer.
■ Stagger the front edge joints between board cladding layers in case of multi-level cladding (approx. 250 mm).
■ Front and long edge joints of cladding on opposing sides must also be staggered to one another.
Board layer 1 horizontal, board layer 2 vertical ■ Board width: 625 mm (lower horizontal layer) ■ Board width: 1250 mm (upper layer vertical) ■ Stud spacing: 625 mm
Long edge
Fron
t edg
e
Front edge
Long
edge
Lower layer: ■ Front edge joints must be staggered by at least one stud spacing. ■ Recommendation: Board length 2500 mm
Upper layer: ■ If floor-to-ceiling boards are not used, stagger the front edge joints ≥ 400 mm.
Offset between lower and upper layer: ■ Stagger the board joints of the upper layer by approx 312.5 mm to the board joints of the lower layer.
Offset of cladding on opposing sides: ■ Board joints must also be staggered to one another
Scheme drawingsInstallation schemesSheet metal insert
≥ 10
0
≥ 100
Sheet metal
General ■ Galvanized sheet metal acc. to EN 10130 and EN 10152, as plates of material or rolls, thickness ≥ 0.5 mm.
■ Screw fastening with drywall screws (only for fastening during cladding and then to be removed)
1 x sheet metal insert between the cladding layers (N)
≥ 50 ≥ 50≥ 100
Sheet metal ≥ 0.5 mm Arrange one sheet metal insert per side, horizontal (preferably) or vertical between the cladding layers, overlap all joints by at least 100 mm, arrange the vertical joints on the studs.
1x sheet metal insert directly on the grid and 1x between the cladding layers (A)
≥ 50 ≥ 50≥ 100
Sheet metal ≥ 0.5 mm
Sheet metal ≥ 0.5 mm
Arrange two sheet metal inserts per side, horizontal (preferably) or vertical between the cladding layers and directly on the grid, overlap all joints by at least 100 mm, range the vertical joints on the studs. Alternatively, butt joint horizontal joints with at least 500 mm offset between both metal layers.
2 x sheet metal inserts between the cladding layers (A)
≥ 50 ≥ 50≥ 100
Sheet metal ≥ 0.5 mm
Sheet metal ≥ 0.5 mm
Arrange two sheet metal inserts per side, horizontal (preferably) or vertical between the cladding layers, overlap all joints by at least 100 mm, arrange the vertical joints on the studs. Alternatively, butt joint horizontal joints with at least 500 mm offset between both metal layers.
Installation and applicationCladding
Scheme drawings I Dimensions in mm
W11
9.de
W11
8.de
56 W11RC.de Knauf Burglar-Retardant Partitions
Installation and applicationCladding
Fastening of the cladding to the stud frame with Knauf drywall screwsCladding Metal stud frame (penetration ≥ 10 mm)
Metal gauge s ≤ 0.7 mm Metal gauge 0.7 mm < s ≤ 2.25 mmThicknessmm
Drywall screwsTN
Diamant screwsXTN or XTB
Drywall screwsTB
Diamant screwsXTB
2x 12.5 – XTN 3.9 x 23 + 3.9 x 38 – XTB 3.9 x 38 + 3.9 x 3812.5 + 0.4+12.5 – XTB 3.9 x 38 + 3.9 x 38 – XTB 3.9 x 38 + 3.9 x 382x 12.5 + 0.4 – XTB 3.9 x 38 + 3.9 x 38 – XTB 3.9 x 38 + 3.9 x 383x 12.5 – XTN 3.9 x 23 + 3.9 x 38 + 3.9 x 55 – XTB 3.9 x 38 + 3.9 x 38 + 3.9 x 5525 + 12.5 TN 3.5 x 35 + XTN 3.9 x 551) TB 3.5 x 45 + XTB 3.9 x 551)
1) Combined cladding (Solid Board + Diamant)
Maximum fastener spacings, all board layers fastened to frame with screwsCladding 1st layer 2nd layer 3rd layer
Vertical Horizontal Vertical VerticalBoard width1250
Board width625
Board width1250
Board width1250
2-layer 750 200 (metal free)600 (with sheet metal insert) 250 –
3-layer 750 – 500 250
Note
For optimum sound insulation arrange the screws as far as possible from the profile lap, i.e. with minimum spacing from edge (10 mm edge covered with board liner, 15 mm cut edge).
Edge spacing
Arrange board joint on centre of profile flange.
Dimensions in mm
W11
9.de
W11
8.de
57W11RC.de Knauf Burglar-Retardant Partitions
Installation and applicationBuilt-ins
Built-insGeneral Openings may be installed at any position between the studs, except not directly opposite one another.With fire resistance:
■ Fire resistance permissible: plug sockets, switch sockets, junction boxes ■ The entry of single electrical cables is permissible, but the remaining openings must be sealed with gypsum mortar.
Knauf gypsum board screws(predrill 6 mm in case of sheet metal insertor sheet metal lamination)
≥ 40
Glue with gypsum mortar
Cladding to suitsystem variant
t
t
Power socket (cavity wall socket)
■ Surround built-ins with gypsum boards (≥ thickness t of the weakened cladding layer).
■ Fixing fire protection covering ▪ 2-layer metal laminated cladding or with sheet metal insert:
Predrill the cladding layers and sheet metal inserts for the cladding us-ing a 6 mm drill bit and then screw in the Knauf screw “Gypsum board screws” into the surround covering.
▪ 2-layer metal free cladding: Install the fire protection covering before installing the second board layer and and screw through the first board layer using Knauf “Gypsum board screws”.
▪ 3-layer cladding with sheet metal insert Before the application of the 2nd sheet metal insert cladding layer and sheet metal layer of the cladding, predrill with 6 mm and then use Knauf “Gypsum board screws” to attach the covering.
Sound insulationNote for avoidance of performance losses in noise reduction measuresAvoid rigid connections with the opposite partition cladding. For further infor-mation on planning and design, see the sound insulation brochure: Interior wall SS04.de (chapter Built-ins - German only).
Scheme drawings I Dimensions in mm Built-in in partitions with resistance class N / A Without fire resistanceBuilt-in ≤ 100 cm²e.g. W118.de N / A
Stud spacing 625 mm
w x h
Up to 100 cm² opeing surface, max. 2 openings per stud partition section (vertical spacing ≥ 1 m).
■ Observe the permissible side ratios w x h ≤ 100 cm² w : h → 1 : 1 to 1 : 2
Built-in ≤ 600 cm² e.g. W119.de N / A
Additional studStud spacing 625 mm
L angle 30/13/0.8circumferential
Diamant Screw
w x h
Additional CW stud
Up to 600 cm² opening surface not in the last stud partition section before the door, opening reinforced with circumferential L-angle, max. 1 opening per stud partition section, one additional stud required in the opening area.
■ Observe the permissible side ratios w x h ≤ 600 cm² w : h → 1 : 1 to1 : 4
W11
9.de
W11
8.de
58 W11RC.de Knauf Burglar-Retardant Partitions
Installation and applicationJointing
JointingJointing of the boards in the required quality level Q1 to Q4 in accordance with Code of Practice no. 2 “Verspachtelung von Gipsplatten, Oberflächengüten”1).Fill in visible screw heads.Suitable jointing materials
■ Uniflott Hand filling without joint tape strips in the long joint edges
■ Uniflott impregnated Hand filling of impregnated boards without joint tape in the long edge joints, water-repellent, matching green colour
■ Fugenfüller Leicht Hand filling with joint tape, preferably with Knauf Fugendeckstreifen Kurt joint tape
Suitable finish filling compounds ■ Q2, application by hand Uniflott, Uniflott imprägniert, Fill & Finish Light, Super Finish
■ Q3/Q4, application by hand Spritzspachtel Plus, Super Finish, Fill & Finish Light
■ Q3/Q4, machine application Spritzspachtel Plus (preferably Q3)
Jointing of the gypsum board jointsFor multi-layer cladding, fill the lower layers with filler; fill the joints of the visible layer. Filling the joints of covered cladding layers with multi-layer cladding is necessary to ensure technical fire protection and sound insulation properties as well as the structural properties.
RecommendedFront edge and cut edge joints as well as mixed joints (e.g. HRAK half-rounded tapered edge + cut edge) of the visible cladding layers filled using Uniflott with Fugendeckstreifen Kurt joint tape as well.Joint filling of the connection jointsApply Trenn-Fix or Fugendeckstreifen Kurt joint tape when filling joints to adjacent drywall constructions, taking into consideration the conditions and requirements for crack resistance.Observe code of practice no. 3 “Gipsplattenkonstruktionen - Fugen und Anschlüsse” (German only)” 1).Apply Trenn-Fix when filling joints to adjacent solid or wooden construction components.SandingLightly sand visible surfaces after drying of the filler material, if required.Application temperature / climateFilling and covering of joints should only take place when no more longitudinal changes can be expected, i.e. expansion or contraction due to humidity or temperature changes. Do not apply filling at room or substrate temperatures below approx. +10 °C.In case of mastic asphalt screed, cementitious screed and self-levelling screed, fill board joints only after screed has been applied.Observe code of practice no. 1 “Baustellenbedingungen” 1).1) Issued by the German Bundesverband der Gipsindustrie e. V.
Quality levels
Joint implementation Long edges half-rounded tapered edge/half-rounded edge
Joint implementationFront edge bevelled cut edge
Descriptionworking steps
Q1 ■ Fill joints with Uniflott or Uniflott imprägniert ■ Fill the visible parts of the fastener
Q2 ■ Preliminary jointing in acc. with quality level Q1 ■ Finish (fine finish compound) to achieve a smooth transition to the board surface e.g. with Uniflott, Uniflott imprägniert, Spritzspachtel Plus, Fill & Finish Light or Super Finish
No application marks or ridges may remain visible. Sand off the areas concerned if necessary.
Q3 ■ Jointing in acc. with quality level Q2 ■ Wide jointing of the joints as well as clean and accurate removal of the remaining board liner filling the pores, e.g. with Fill & Finish Light, Super Finish or Spritzspachtel Plus
If necessary, i.e. physical ridges and grooves are not acceptable and must be sanded.
Q4 ■ Jointing in acc. with quality level Q2 ■ Complete surface covering of skim coat with a layer thickness of at least 1 mm, e.g. with Fill & Finish Light, Super Finish or Spritzspachtel Plus
W11
9.de
W11
8.de
59W11RC.de Knauf Burglar-Retardant Partitions
Installation and applicationCoatings and linings
Coatings and liningsCoating / lining Recommended finish
Gypsum boardsEN 520
Tiles etc. Q1Coarsely structured wallpaper (e.g. wood-chip wallpaper) Q2
Finely structured wallpaper Q3/Q4Matt textured coats Q3/Q4Glossy, smooth coats Q4Plasters (grain size < 1 mm) Q3/Q4Plasters (grain size ≥ 1 mm) Q2
PretreatmentBefore a further coating or lining is applied, the filled surface must be free of dust. Prime acc. to code of practice no. 6 of the BVG “Vorbehandlung von Trockenbauflächen aus Gipsplatten zur weitergehenden Oberflächenbeschichtung bzw -bekleidung” 1).The primer must suit the subsequent coating compound/coatings/linings.In order to compensate for the differences in absorption of surfaces, coatings of primer such as Knauf Tiefengrund primer is suitable.Where a wallpaper lining is used, a primer that facilitates easier removal of wallpaper for redecoration is recommended.When using in damp rooms and rooms with high levels of humidity, observe code of practice no. 5 “Bathrooms and wet rooms in timber and drywall construction (German only” 1)
Note
Gypsum board surfaces that have constantly been exposed to light without any protection can result in yellowing. Therefore, a trial coat is recommended that will extend across several boards including all joints. Yellowing can, however, be successfully avoided only by using a special primer, e.g. Aton Sperrgrund for finishing plasters, Knauf Sperrgrund for coatings.
Suitable coatings and liningsThe following coatings/linings can be applied to Knauf boards:
■ Wallpapers ▪ Paper, fleece, textile and synthetic wallpapers
Use only adhesives made of methyl cellulose according to Code of Practice no. 16 “Technische Richtlinien für Tapezier- und Spannarbeiten innen” 2) released by the Bundesausschuss Farbe und Sachwertschutz.
■ Plaster and filler materials ▪ Top coats (e.g. Noblo, Raumklima Spritzputz spray plaster, Rotkalk Filz) ▪ Full surface plaster (e.g. Spritzspachtel Plus).
Application of plaster layers only in conjunction with Fugendeckstreifen Kurt joint tape.
■ Coatings ▪ Dispersion paint (e.g. Intol E.L.F., Malerweiss E.L.F.) ▪ Silicate-based emulsion paints with suitable primer. ▪ Others on request
■ Ceramic coverings (e.g. tiles) ▪ Tile weights up to 25 kg/m2 (one-sided) with a max. surface per tile of
1800 cm2 (e.g. 60 x 30 cm) have proven to be uncritical (compare to code of practice 8:2019-12 Partition heights of lightweight partitions1)).
Unsuitable coatings and linings ■ Alkaline coats such as lime, water glass paints and silicate-based paints.
Notes
After wallpapering or after application of plasters, quick drying must be ensured through adequate airing.Other coatings or layers and vapour barriers up to about 0.5 mm thickness as well as claddings (with the exception of sheet steel), do not have any influence on the technical fire resistance classification of the Knauf Burglar-Retardant Partitions.
1) Issued by the German Bundesverband der Gipsindustrie e. V.2) Issued by the German Bundesausschuss Farbe und Sachwertschutz W
119.d
eW
118.d
e
Find the ideal systems for your requirments!knauf.de/systemfinder
All technical changes reserved. Only the current printed instructions are valid. The stated information represents current state-of-the-art Knauf technology. The entire state of approved engineering rules, appropriate standards, guidelines, and rules of crafts-manship are not included herewith. These and all application instructions have to be adhered to separately by the installer. Our warranty is expressly limited to our products in flawless condition. All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areas.All rights reserved. All amendments, reprints and photocopies, including those of excerpts, require our expressed permission.
The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components, or other products expressly recommended by Knauf.
Knauf Gips KG Am Bahnhof 7, 97346 Iphofen, GermanyKnauf DirectTechnical Advisory Service:
www.knauf.de
W11RC.de/eng/12.20/0/Dbl
Information on sustainabilityKnauf Burglar-Retardant Partitions
Information on sustainability of Knauf burglar-retardant partitionsBuilding assessment systems ensure the sustainable quality of buildings and constructional structures by a detailed assessment of ecological, economic, social, functional and technical aspects.The following certification systems have a particular relevance in Germany
■ DGNB System German seal of approval for environmentally sustainable building from the DGNB (German association for environmentally sustainable building)
■ BNB (Bewertungssystem Nachhaltiges Bauen - Quality rating system for environmentally sustainable building)
■ LEED (Leadership in Energy and Environmental Design).
Knauf products and Knauf Burglar-Retardant Partitions can positively influence many of these criteria.DGNB/BNBEcological quality
■ Criterion: Risks for the local environment The relevant environmental data are contained in the EPD for gypsum products
Economic quality ■ Criterion: Building related life-cycle costs Cost-effective Knauf Drywalling
Sociocultural and functional quality ■ Criterion: Space efficiency Slim, floor-space enhancing Knauf Burglar-Retardant Partitions
■ Criterion: Suitability for conversion Flexible Knauf Drywalling
Technical quality ■ Criterion: Sound insulation Exceeding the demands of the standard with Knauf sound protection
■ Criteria: Ease of dismantling and recycling Knauf Drywalling is fully compliant
LEEDMaterials and resources
■ Credit: Recycled Content Recycled content in Knauf boards
■ Credit: Regional Materials Short transport routes provided by the extensive network of Knauf manufacturing facilities
Videos for Knauf systems and products can be found under the following link:www.youtube.com/knaufEPD
The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable way.Knauf Infothek