kimmco-isover selection criteria of insulation for...
TRANSCRIPT
KIMMCO-ISOVERKIMMCO-ISOVER
SELECTION CRITERIA OF INSULATION FOR
BUILDING CONSTRUCTION
KIMMCO-ISOVER
SELECTION CRITERIA – MINERAL WOOL INSULATION
ACOUSTIC PERFORMANCE
1 / Selection Criteria - Doha
SUSTAINABILITY
FIRE PERFORMANCE
THERMAL PERFORMANCE
KIMMCO-ISOVER
2 / Selection Criteria
KIMMCO-ISOVER
SELECTION CRITERIA – MINERAL WOOL INSULATION
3 / Selection Criteria - Doha
THERMAL PERFORMANCE
Minimum Thickness
(condensation prevention)
K Value
(Energy Saving)
KIMMCO-ISOVER
THERMAL PERFORMANCE – MINIMUM THICKNESS
25 ºC
0.029
0.031
0.033
0.035
0.037
0.039
0.041
0.043
0.045
0.047
0.049
10 20 30 40 50 60 70 80 90 100 110 120
Ther
mal
Con
duct
ivit
y W
/m.ᵒ
k
Density Kg/mᵌ
10 ºC
25 ºC
4 / Selection Criteria
Lambda has always to be compared at the same temperature
In Europe Value measured at 10ºC, USA 24ºC & Japan 25 ºC
Optimum
Density
Range
R =k
t
KIMMCO-ISOVER
1. PAHW STANDARD HOUSE (WITHOUT ETICS)
2. + 12 CM MINERAL WOOL ETICS ON EXTERNAL WALLS + 6 CM MINERAL WOOL ON ROOF
3. + 6 CM MINERAL WOOL ETICS ON EXTERNAL WALLS + 6 CM MINERAL WOOL ON ROOF
ROOM TEMPERATURE
SETTING: 23 °C
MINERAL WOOL INSULATION - ENERGY SAVING
TOTAL EXTERNAL WALL: 456 M2
ROOF AREA: 234.5 M2
WINDOWS & DOORS: 50.7 M2
COLUMNS & BEAMS: 30%
4 / Selection Criteria - Doha
KIMMCO-ISOVER
MINERAL WOOL INSULATION - ENERGY SAVING
ETICS = EXTERNAL THERMAL INSULATION COMPOSITE SYSTEM
AACB
ADHISIVE MORTAR
INSULATION FASTNER
BASE MORTER WITH GLASS FIBER MESH
DECORATIVE COLORED RENDER
BASE BAR
MINERAL WOOL INSULATION BOARD
6 / Selection Criteria - Doha
KIMMCO-ISOVER
B1(reference)
B2(12 cm SW ETICS +
6 cm SW roof)
B3(6 cm SW ETICS +
6 cm SW roof)
Walls CB* Roof Walls CB Roof Walls CB Roof
U-Value(W/m2.°K)
0.58 2.52 0.31 0.21 0.29 0.21 0.31 0.53 0.21
Combined Walls(including door & windows)
R-value(h.ft2.°F/Btu)
6.51 18.31 22.3 27.58 14.2 27.58
* CB Columns and Beams.
Building
Element
MINERAL WOOL INSULATION - ENERGY SAVING
KIMMCO-ISOVER
THERMAL IMAGE ANALYSIS ON INTERNAL WALLS
MINERAL WOOL INSULATION - ENERGY SAVING
7 / Selection Criteria - Doha
KIMMCO-ISOVER
B2 WITH 12 CM STONE WOOL ETICS = 41% LESS COOLING DEMAND / PEAK POWER
B3 WITH 6 CM STONE WOOL ETICS = 31% LESS COOLING DEMAND / PEAK POWER
•0 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3
•4
•2
•6
• 3
•0
•5
•1
•B 1 (NO INSULATION)
•B2 ( 1 2 C M IN SU LA TIO N )
•B3 ( 6 CM INSULATIO N)
•AMBIENT DRY BULB TEMPERATURE
•40
•20
•30
•0
•50
•10
Time of the Day (hr)
MINERAL WOOL INSULATION - ENERGY SAVING
8 / Selection Criteria - Doha
KIMMCO-ISOVER
B2 WITH 12 CM MINERAL WOOL ETICS = 46.1% LESS ENERGY COOLING & ELECTRIC POWER
B3 WITH 6 CM MINERAL WOOL ETICS = 38.9% LESS ENERGY COOLING & ELECTRIC POWER
•60 80 100 120 140 160 180 200 220 240 260 280 300 320
•45
•40
•25
•20
•35
•30
•15
•10
•5
•0
•B2 (12 CM INSULATION)
•B3 (6 CM INSULATION)
Days of the year
MINERAL WOOL INSULATION - ENERGY SAVING
9 / Selection Criteria - Doha
KIMMCO-ISOVER
SELECTION CRITERIA – MINERAL WOOL INSULATION
10 / Selection Criteria - Doha
Smoke Emission
(smoke toxicity)
Reaction To Fire
(Flash Over)
FIRE PERFORMANCE
Droplets
(flammable particles)
KIMMCO-ISOVER
MINERAL WOOL INSULATION – FIRE PERFORMANCE
Fire Behaviour:
A1: No Flash Over
A2: No Flash Over
B : No Flash-over
C: Flash Over between 10 – 20 Minutes
D: Flash Over between 2 – 10 Minutes
E: Flash Over before 2 Minutes
Smoke emission : s1-s3
s1: Absent/weak smoke emission
S2: Medium smoke emission
s3: High smoke emission
Burning incandescent droplets :
d0: Absent/slow
d1: Medium
d2: High amount of droplets11 / Selection Criteria
Euro Class –(EN 13501)
KIMMCO-ISOVER FIRE CLASSIFICATION – INSULATION MATERIAL
Source: Roxul
**
Ceramic fiber
12 / Selection Criteria - Doha
KIMMCO-ISOVER
MINERAL WOOL – FIRE COMPLIANCE TO (EN 13501)
13 / Selection Criteria
Mineral Wool only (LD)
A2,s1d0 Mineral Wool GW & SW (HD)
FIRE
SAFE
B,s1d0
C,s3d2 Polyolefin, PIR , PUR , PE
D,s3d3 EPS , XPS
A1,s1d0 Mineral Wool GW & SW (LD)
Faced Mineral Fiber + phenolic Foam
KIMMCO-ISOVER
SELECTION CRITERIA – MINERAL WOOL INSULATION
14 / Selection Criteria - Doha
SOUND ABSORPTION
(NRC)
SOUND TRANSISION
(STC)
ACOUSTIC PERFORMANCE
IMPACT SOUND
(IIC)
KIMMCO-ISOVER
MINERAL WOOL INSULATION – ACOUSTIC PERFORMANCE
5 / Selection Criteria
STC up to 70 dB NRC up to 1.05
Glasswool
Mineral
wool
Insulation
Mineral
wool
Insulation
Decorative
Finish
Concrete
IIC Up to 36
KIMMCO-ISOVER
SELECTION CRITERIA – MINERAL WOOL INSULATION
1 / Selection Criteria - Doha
ENERGY OPTIMIZATION
THERMAL COMFORT
sustainability
Low EMITTING MATERIAL
REGIONAL MATERIAL
KIMMCO-ISOVER
sand Recycled CulletFurnace
Mineral Wool
MINERAL WOOL - SUSTAINABILITY
FROM NATURE TO NATURE
NO STRATEGIC MATERIAL USED
UP TO 80% RECYCLED CONTENT
15 / Selection Criteria - Doha
KIMMCO-ISOVER
150 kWh/m²a
Equivalent to 15
m³ natural gas
or
15 L extra light oil
CO2 = 30 kg/m²a CO2 = 2 kg/m²a
15 kWh/m²a
Equivalent to
1.5 m³ natural gas
or
1.5 L extra light oil
U-value = 0.10
U-value = 0.10U-value = 0.22
U-value = 0.40
Re
duction
of h
ea
ting/c
oolin
ge
ne
rgy
5 / Selection Criteria
MINERAL WOOL - SUSTAINABILITY
KIMMCO-ISOVER
SELECTION CRITERIA – MINERAL WOOL INSULATION
1 / Selection Criteria - Doha
Mineral Wool Contribute up to
27 point
according to LEED criteria
VOC ≤ 0.27 g/l
KIMMCO-ISOVER