Pure Drinking Water Tank
KPIC - POLYETHYLENE WATER TANKManufactured to the best quality with less maintenance. Our tanks are de-signed to protect against mold, micro-organisms, bacterias, fungi & algae.
Produced from non toxic material and approved for storage and handling po-table water as well as Insulated from external heat.
ROTOMOULD (POLYETHYLENE)WATER TANKS
• Vertical Polyethylene Water tanks
• Horizontal Polyethylene Water tanks
• Rectangular Polyethylene Water tanks
ADVANTAGES
• Corrosion Free• Easy handling and installation• Proven resistance to acidic environ-
ment in water system• Low maintenance cost• Low transport cost• Weight Advantages• Portable• Flexibility
APPLICATIONS
• Drinking Water tank• Septic tank• Sewage Water tank• Potable Water tank
• Irrigation water tank
COMPONENTS
LLDPE : Copolymer is designed to provide excellent stress crack resistance, high rigidity, toughness, gloss and very low warpage. The resin contains UV stabilizer.
Approved by Water Regulations Advisory Scheme
BS 6920 : 2000
Eco Friendly
Recyclable Products
Ozone
DIMENSION OF VERTICAL TANKS
CAPACITY DIA HEIGHT THICKNESS
1000 GALLON 1700 MM 2030 MM 19 MM
2000 GALLON 2170 MM 2570 MM 21 MM
250 GALLON 1100 MM 1270 MM 16 MM
1200 GALLON 1750 MM 2070 MM 20 MM
100 GALLON 830 MM 1050 MM 16 MM
3000 GALLON 2420 MM 2770 MM 23 MM
400 GALLON 1270 MM 1580 MM 18 MM
1000 GALLON (S.H) 2400 MM 1200 MM 20 MM
2500 GALLON 2320 MM 2620 MM 22 MM
300 GALLON 1170 MM 1430 MM 18 MM
800 GALLON 1590 MM 1900 MM 18 MM
1500 GALLON 1940 MM 2340 MM 20 MM
200 GALLON 1020 MM 1260 MM 16 MM
5000 GALLON 2830 MM 3380 MM 25 MM
600 GALLON 1440 MM 1790 MM 18 MM500 GALLON 1310 MM 1790 MM 18 MM
SPECIFICATIONITEM DESCRIPTION
Skin Thickness Up to 10 mm
No. of Chambers One
Manhole Diameter up to 500
Inlet Connection up to 6 inch dia uPVC Pipe
Outlet Connection up to 6 inch dia uPVC Pipe
Air Vent up to 20 mm height and 30 mm dia
Layers Properties 3 layers (White, Black, White)
BILL OF MATERIALSITEM DESCRIPTION QTY
1 Manhole cover 1
2 Air vent 1
VERTICAL WATER TANK
1
2
Connection point
DRAWING WATER TANK
500
200
200
TOP
VIEW
15m
m T
hick
ness
Air
vent
Det
ail
Hei
ght
20 m
m
Dia
50
mm
FRO
NT
VIE
WTO
P V
IEW
DIMENSION OF HORIZONTAL TANKS
CAPACITY LENGTH HEIGHT THICKNESS
1000 GALLON 2330 MM 1550 MM 19 MM
200 GALLON 1290 MM 885 MM 16 MM
100 GALLON 1050 MM 790 MM 16 MM
400 GALLON 1690 MM 1130 MM 18 MM
250 GALLON 1380 MM 920 MM 18 MM
800 GALLON 2100 MM 1390 MM 18 MM
150 GALLON 1180 MM 780 MM 16 MM
600 GALLON 2010 MM 1330 MM 18 MM500 GALLON 1810 MM 1180 MM 18 MM
SPECIFICATIONITEM DESCRIPTION
Skin Thickness Up to 10 mm
No. of Chambers One
Manhole Diameter up to 500
Inlet Connection up to 6 inch dia uPVC Pipe
Outlet Connection up to 6 inch dia uPVC Pipe
Air Vent up to 20 mm height and 30 mm dia
Layers Properties 3 layers (White, Black, White)
BILL OF MATERIALSITEM DESCRIPTION QTY
1 Manhole cover 1
2 Air vent 1
1
2
HORIZONTAL WATER TANK
DIMENSION OF RECTANGULAR TANKS
CAPACITY LENGTH WIDTH HEIGHT
400 GALLON 2000 MM 1880 MM 490 MM
100 GALLON 1300 MM 985 MM 390 MM
500 GALLON 2000 MM 2000 MM 500 MM
200 GALLON 1565 MM 1285 MM 430 MM
SPECIFICATIONITEM DESCRIPTION
Skin Thickness Up to 10 mm
No. of Chambers One
Manhole Diameter up to 500
Inlet Connection up to 6 inch dia uPVC Pipe
Outlet Connection up to 6 inch dia uPVC Pipe
Air Vent up to 20 mm height and 30 mm dia
Layers Properties 3 layers (White, Black, White)
BILL OF MATERIALSITEM DESCRIPTION QTY
1 Manhole cover 1
2 Air vent 1
1
2
RECTANGULAR WATER TANK
The KPIC range of polyethylene storage tanks are manufactured in compliance to interna-tional standards using only the highest quali-ty materials, however improper handling and installation can cause damage to the tanks and their fittings.Warranty may be void if there is a failure on handling & installation of the tanks.To avoid problems , guidelines are provided for the customers compliance for delivery, handling & installation.
Delivery and Handling
Upon delivery, it is the customer’s responsi-bility ity to safely unload the tank from the delivery vehicle. Unless agreed prior to de-livery, the standard delivery vehicles do not have the facilities to unload your tank.
Delivery is completed once the customer has thoroughly inspected the item without any defect. if any defect was found on the item , customer should immediately report the case for the company to resolve the problem in quickest possible way.
The tank should be unloaded onto a smooth, flat surface that is free from rocks and other sharp objects that could cause damage. extra attention must be given to damage caused by fork lift truck blades. It is highly recommend-ed that a mobile lifting equipment (crane, forklift truck, etc.) is used to lift large tanks from the lorry.
When your tank is being unloaded, moved or in-stalled, damage to tank fittings must be avoided. Do not allow the weight of the tank to rest on any of the fittings and do not roll the tank over any of its fittings.
Installation
It is very important that tanks are installed on a smooth, firm surface that can fully support the weight of the tank. In most all situations a rein-forced concrete base is the best solution. Even when a tank stand is used, the stand must be mounted on a solid base.
Consider the location of the installation and be sure that there is enough room to carry out any maintenance activities. Polyethylene tanks may contract or expand due to temperature chang-es, atmospheric conditions and the nature of the contents.
Work activities that will take place in the vicinity must be taken into consideration precaution any measure to avoid accidental contact with the tank. failure may be a result of impact especially in cold conditions.
The tank is not designed to support the weight
DELIVERY, HANDLING &INSTALLATION
FOR MORE INFORMATION
Give us a call
Tel no.: +97444367821
Email : [email protected]
of machinery or equipment. Do not mount items like this on top of the tank or on its fittings.If human access is necessary, great care should be taken to avoid asphyxiation by inhaling of hazardous vapor and fumes.
Tank Use
The tanks should only be used for what it was pur-pose for designed. Do not apply contents under pressure or create a vacuum unless the tank is spe-cifically rated.
Make sure that the materials stored in the tank are appropriate for the properties of the tank, fittings, gaskets and accessories.
KHALID PLASTIC INDUSTRIES COMPLEX W.L.L P.O.Box:1511, Doha,State of QatarE-Mail: [email protected],[email protected] Web: www.kpic.com
Tel no +974 44367821, Fax No : +974 44630754Khalid Khalid