kek workshopwalter wuensch18 april 2012 status and objectives of the clic x-band and high- gradient...

18
KEK workshop Walter Wuensch 18 April 201 Status and objectives of the CLIC X-band and high-gradient activity

Upload: bernard-webster

Post on 19-Jan-2016

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Status and objectives of the CLIC X-band and high-gradient activity

Page 2: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Status

As you will hear in this workshop, we have mostly completed the feasibility demonstration of 100 MV/m accelerating gradient for CLIC accelerating structures.

Not only have we operated a number of structures in the range of 80 to 120 MV/m, we have done this:• At low, order of 10-7 bd/pulse/meter rate• With the CLIC pulse shape• Predictably• ReliablyAnd at a bit above 100 MV/m:• With higher-order-mode damping features

We have built up a rather clear understanding of how the structures behave – geometrical, gradient, pulse length, statistical etc. dependencies.

And to a large extent we also understand why. The mists are rapidly clearing from breakdown and other high-gradient and high-power phenomena.

Page 3: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Acknowledgements

Many of you have participated in this effort to raise the practical accelerating gradient from 30-50 MV/m up to 100-120 MV/m.

I would like to thank you all personally, and on behalf of the CLIC collaboration, for this excellent progress.

I would also especially like to thank our Japanese colleagues and hosts for their enormously valuable contributions and their

impressive recovery from the big earthquake last year! We also all appreciate that we can have this meeting here this year.

Page 4: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

I look forward to hearing in the coming days about all the progress we have made.

But there is still a lot more work, and opportunity, ahead – both for CLIC but also for spreading the technology we have developed to other high-gradient, normal conducting applications.

We are here.

Page 5: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Some thoughts about the next steps

Here’s a partial list of some subjects we must address next. Some work you will already hear about in the next days. I will mention some detail on the first four:

• Measure the effect of beam loading on breakdown rate.• Understand the difference between damped and undamped structures – 20% gradient

to be gained.• Increase and spread high-power generation and testing capability.• Need to test more structures and for longer.• Reproduce results with compact power couplers and damping load material installed.• Re-optimise CLIC linac for staged energies and higher efficiency.• Investigate alternative structures – choke mode, DDS, quadrants – as well as crab and

deflecting cavities.• Optimize the fabrication method and get ready for mass production.• Advance theoretical and experperimental study of breakdown and high-gradient

phenomena.

Page 6: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

The effect of beam loading on breakdown rate

Since we must be efficient, we have significant levels of beam loading in our structures. That is the beam pulls down the fields a lot.

We will need to raise input power to compensate for beam loading as we increase current, even while the ‘average’ fields stay the same.

What happens to the breakdown rate?

Page 7: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Accelerating gradient test status: 6-3-2012

Uncertainty range due to the effect of beam loading. This will be measured for the first time in the “dog-leg.”

n.b. TD24 point corresponds to no breakdowns in 250 hr → 4.5x107 pulses

On going test→

Page 8: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

The effect of beam loading on breakdown rate

Since we must be efficient, we have significant levels of beam loading in our structures.

We will need to raise input power to compensate for beam loading as we increase current, even while the ‘average’ fields stay the same.

What happens to the breakdown rate?

We are preparing an experiment in CTF3 using mostly existing equipment to measure this effect.

Page 9: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

1-5 A beam

CTF2

Front end of CTF3 drive beam linac

0 5 10 15 20 250

50

100

150

200

250

300

iris number

47.1 37.4

229 227

5.7

4.3

118119

Sc½ [MW/mm2]

Es max [MV/m] Eacc [MV/m]ΔT [°C]dashed – unloadedsolid – loaded

CTF3

Page 10: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

0 2 4 6 8 10 12 14 16 180

50

100

150

200

250

iris number

P [

MW

] (b

lack

), E

s (

gre

en),

Ea (

red

) [M

V/m

],

T

[K

] (b

lue)

, S

c*50

[MW

/mm

2 ] (m

agen

ta)

8.1 12.5

148

232

2.7

4.4

76

126

53.0

37.4

Pinload = 53.0 MW, P

outload = 37.4 MW

Eff = 0.0 % tr = 0.0 ns, t

f = 0.0 ns, t

p = 100.0 ns

T18

0 5 10 15 200

10

20

30

40

50

Cell No.P

erc

en

t of B

KD

Eve

nts

394 BKDs within 0~250hrs193 BKDs within 250~500hrs298 BKDs within 500~750hrs57 BKDs within 750~900hrs74 BKDs within 900~1000hrs34 BKDs within 1000~1200hrs24 BKDs within 1200~1400hrs

0 2 4 6 8 10 12 14 16 180

50

100

150

200

250

iris number

P [

MW

] (b

lack

), E

s (

gre

en),

Ea (

red

) [M

V/m

],

T

[K

] (b

lue)

, S

c*50

[MW

/mm

2 ] (m

agen

ta)

30.6

49.4

157

234

3.3

4.5

79

120

56.8

33.8

Pinload = 56.8 MW, P

outload = 33.8 MW

Eff = 0.0 % tr = 0.0 ns, t

f = 0.0 ns, t

p = 100.0 ns

0 5 10 15 200

50

100

150

200

250

Regular Cell No.

BD

R E

ven

ts

0 ~ 200 hrs200 ~ 400 hrs400 ~ 600 hrs600 ~ 700 hrs700 ~ 960 hrs 0 ~960 hrs

TD18

Trying to understand existing data

Why is BDR dependence on fields so strong for the whole structure but so weak inside the structure?

Page 11: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

We see approximately 20% less gradient in damped structures compared to undamped ones with the same irises.

Why?

The difference between damped and undamped performance

Page 12: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Accelerating gradient test status: 6-3-2012

Uncertainty range due to the effect of beam loading. This will be measured for the first time in the “dog-leg.”

n.b. TD24 point corresponds to no breakdowns in 250 hr → 4.5x107 pulses

On going test→

Page 13: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

During post-mortem inspections of T18 and TD18 structures we have observed evidence of high-power related activity in cell-to-cell contacts.

We see two categories of activity:

• One fixed at the specific points in the TD18 where the surface current density is highest.

• The other at random points around the circumference at points of much lower current density.

All the images after high power testing I will show are from KEK/SLAC fabrication.

The difference between damped and undamped performance

Page 14: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Features in high current region of TD18

Damping waveguide

Inner cell

Current density around 2x108A/cm2 during test

Page 15: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

So does this evolve… …into this?

An effect of surface tension plus electromigration?

If the such localized flow features exist, the surface currents will preferentially flow though them. We get a current enhancement, increasing pulsed surface heating and electromigration. These combined effects could then have a positive feedback and produce an instability.

Page 16: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

The effect of surface currentsCell # (cell #1 is a input matching cell): 4 5 6 7 8 9 10 11 12 13 15 14 17

?16?

Images courtesy of M. Aicheler: http://indico.cern.ch/getFile.py/access?contribId=0&resId=1&materialId=slides&confId=106251

18

Last regular cell: 19

It seems that cell #10 (regular cell #9 ~ middle cell) exhibits the level of damage which could be considered as a limit.

A. Grudiev

TD24

Page 17: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Status of X-band test areas

Existing areas:• NEXTEF, KEK – Running and running and running. Full program. We hope to

continue for many years more.• NLCTA, SLAC – We had some great times but is now entirely dedicated to

photon science.• ASTA, SLAC – Is available for testing but on a full cost basis only. • Klyston at CERN – Still commissioning.

We intend to supplement these stands with:• A test stand at CERN using the first 50 MW XL-5 tube from CPI that we’ve

ordered.• A test stand at a collaborator using the second 50 MW XL-5 tube from CPI

that we’ve ordered.• A test stand at CERN based on a combined 5 MW, high-repetition rate

tubes.

Page 18: KEK workshopWalter Wuensch18 April 2012 Status and objectives of the CLIC X-band and high- gradient activity

KEK workshop Walter Wuensch 18 April 2012

Budget and technical profile in the medium term

Budget [MCHF] 2012 2013 2014 2015 2016 2017 Design 0.2 0.2 0.2 0.2 0.2 0.2 Production 1.2 1.6 1.9 2.4 2.8 2.8 Test areas 2.8 2.8 2.8 0.0 0.0 0.0 8.4Testing 0.3 0.4 0.6 0.7 0.8 0.8 High gradient 0.2 0.2 0.2 0.2 0.2 0.2 Totals 4.7 5.2 5.7 3.5 4.0 4.0 27.1 Cost inputs Infrastucture rf Total Initial installation for test stands 1.7 1.7 Marginal cost for one test stand 0.2 1.8 2 Full cost structure 0.3 Testing year cost per stand 0.12 KEK Operate CERN 1 (SLAC) CERN 2 (CPI1) Collaborator (CPI2) CERN3 (5 MW) SumNumber 50 MW stands 1 2 3 4 4 4 18Number 5 MW stands 0 0 0 0 1 1 Number structures tested 2 4 6 8 12 12 44