What is an Equal Potential clamp?
An Equal Potential Clamp is a device than equalises two different potentials .
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 3: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/3.jpg)
What causes unequal potentials ?
Unexpected rises between different power systems as a result of LIGHTNING, WIND, ACCIDENT or SYSTEM MALFUNCTION.
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 4: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/4.jpg)
WHAT STOPS IT ?
A passive component that forms a hard bond between the potentials to reduce the difference to a
safe level..
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 5: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/5.jpg)
A Large Gas Arrestor !
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 6: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/6.jpg)
How good is it ?
ARRESTOR PERFORMANCE Voltage 70volts Energy rating 500 kA 8/20 uS Gas Arrestor 2 terminal device Spark over Voltage 56 ~ 84 VDC Max Impulse Breakdown <600v / uS … 100v/uS Nominal AC Discharge Current 500 Amps DC Holdover Voltage 50 volts Nom. alternating discharge Current (50 hZ 9 cycles) (A) 4000 Amps Long duration surge 4kA for > 400 mS Nominal Impulse Discharge 200KA 10/350uS Insulation Resistance > 10 megohm Series impedance once fired < 0.025 ohms Max Capacitance <20 pF Storage / operating Temp -40 ~ +90 C Weight 0.5kgs
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 7: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/7.jpg)
What Happens ? When a voltage is applied across the terminals in excess of 70 volts the gas fires . When this happens it effectively creates a short circuit across the terminals to create a “HARD BOND” [resistance <0.025 ohms].
This bond will continue until the voltage reduces below 70 volts. ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 8: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/8.jpg)
Should the voltage surge extend beyond 400 ms the arrestor will become hot. This heat increase triggers a solenoid that immediately activates a solid bar to place a direct short across the terminals. This direct short continues until the temperature of the arrestor falls 15 degrees below the activation level.If the voltage is still in excess of the trigger voltage the sequence continues until the problem is resolved or an external source removes the potential.
![Page 9: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/9.jpg)
Shorting bar4 x Silver plated contacts .. 20mm dia.
Gas arrestor
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 10: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/10.jpg)
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 11: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/11.jpg)
Heat sensor
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 12: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/12.jpg)
12 volt Battery for solenoid
System Test shield
Heavy duty solenoid
Cable connection
![Page 13: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/13.jpg)
Long life 12v heavy duty rechargeable battery.Easy changeover or optional charger / solar
panel available
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 14: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/14.jpg)
M20 brass studs for cable terminations x 2Cables enter via cable glands in base of IP66 rated cabinet
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 15: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/15.jpg)
HOW DO I TEST THE SOLENOID AND BATTERY ?
GUARD INSULATOR ……. NORMAL
GUARD INSULATOR …. NORMAL OPERATED / CONTACTS CLOSED
GUARD INSULATOR IN TEST POSITION.. INSULATOR COVERS CONTACTS WHEN TEST SWITCH PUSHED ………….RETURN GUARD TO NORMAL AFTER TEST
![Page 16: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/16.jpg)
Where should I use an Equal potential clamp ?
•Wherever a need exists to clamp 2 separate electrical earthing systems together during fault conditions ONLY.
•Where-ever protection is necessary on ELV equipment against very high sustained surges and overvoltage conditions.
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 17: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/17.jpg)
Bonding Two Separate Electrical Systems
Operational conditions need these 2 systems be separated.
However for safety reasons these separate systems should be bonded together.Possible dangerous touch potentials exist.Damage to equipment that could cause a disaster.
![Page 18: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/18.jpg)
Bonding Two Separate Electrical Systems
![Page 19: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/19.jpg)
Protection of ELV Equipment
Areas may have high voltages present that can damage ELV equipment.
•Conductors attached to these circuits may be exposed to surge voltages and currents during fault conditions.
•In areas of high vulnerability, it may be advisable to ensure the fault current has a predetermined path.
![Page 20: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/20.jpg)
Protection of ELV Equipment
![Page 21: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/21.jpg)
Protection of ELV Equipment
![Page 22: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/22.jpg)
Where could this happen ?
![Page 23: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/23.jpg)
The highest risk of contact wire droppage is at level crossings !
TrucksHigh machinery
CranesDouble deck busesRadio aerials and
Ladders. ht
![Page 24: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/24.jpg)
Indirect damage from wire drop will mostly be to track circuit equipment as a minimum.
Such as:-Track relays
Surge arrestorsTrack circuit wiringTrack circuit fuses
plus unknown signaling equipment
![Page 25: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/25.jpg)
How can we mitigate this direct damage ?
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 26: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/26.jpg)
How can we mitigate this direct damage ?
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 27: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/27.jpg)
ANSWER !!KAYSAN
Equal Potential Clamp
KEP - 1000
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT
![Page 28: KAYSAN EQUAL POTENTIAL CLAMP](https://reader035.vdocuments.us/reader035/viewer/2022062800/56814133550346895dad1d2a/html5/thumbnails/28.jpg)
Made and Designed in New Zealand by KaysanGas Arrestor Made by Prosurge Electronics
for Kaysan
A member of GRS.
ENGINEERED WITH QUALITY
DESIGNED WITH THOUGHT