kardia hand pump guideline - inter...

6
1 European Union Inter Aide Sierra Leone Kardia Hand Pump Guideline

Upload: others

Post on 19-Aug-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Kardia Hand Pump Guideline - Inter Aideinteraide.org/watsan/sl/wp-content/uploads/2015/08/Guideline_Kardi… · Kardia Hand Pump Guideline . 2 I. The Head Assembly You can dismantle

1

European Union Inter Aide

Sierra Leone

Kardia Hand Pump

Guideline

Page 2: Kardia Hand Pump Guideline - Inter Aideinteraide.org/watsan/sl/wp-content/uploads/2015/08/Guideline_Kardi… · Kardia Hand Pump Guideline . 2 I. The Head Assembly You can dismantle

2

I. The Head Assembly

Handle

You can dismantle the head

assembly with an Allen key 8

mm.

Flange Bearing

Flange bearings are different according to the

type of Kardia (Kardia 65/Kardia 2000).

Cost: 265 000 Leones for 1 so, 530 000 Leones

for the set.

Link Head

¼ Bolt (24 mm Bolt)

Link head is different according to the type

of Kardia (Kardia 65/Kardia 2000).

Cost: 175 000 Leones

Cost: 145 Leones

Connecting Rod

Riser Pipe

Water Tank

Page 3: Kardia Hand Pump Guideline - Inter Aideinteraide.org/watsan/sl/wp-content/uploads/2015/08/Guideline_Kardi… · Kardia Hand Pump Guideline . 2 I. The Head Assembly You can dismantle

3

Clip

Before removing the water tank and the pipes,

you need to unscrew the clip of the water tank

On Kardia, it is difficult to work with a

connecting rod clamp. That is why in the tool

box you will find a rod plier

Use 2 spanners (22 mm & 24 mm)

to unscrew the ¼ Bolt.

Rod plier

Page 4: Kardia Hand Pump Guideline - Inter Aideinteraide.org/watsan/sl/wp-content/uploads/2015/08/Guideline_Kardi… · Kardia Hand Pump Guideline . 2 I. The Head Assembly You can dismantle

4

II. The Low Assembly

You need 2 riser pipe clamps (picture

above) to work on Kardia and 2 riser pipe

pliers in order to unscrew the pipes

Long Nut

Connecting Rod

Connecting Rod

Riser Pipe

Riser Pipe

For 1 pipe, you have 1 connecting rod of the same

size. You can find only three sizes: 3m, 1m, 0.5m.

Rods are linked together by a long nut

Pipe socket

DN40

Page 5: Kardia Hand Pump Guideline - Inter Aideinteraide.org/watsan/sl/wp-content/uploads/2015/08/Guideline_Kardi… · Kardia Hand Pump Guideline . 2 I. The Head Assembly You can dismantle

5

III. The Cylinder (Kardia 2000)

Reducer

Rubber seating

Foot valve

Screen Pipe

Make sure that holes of the

valve plate are matching with

the ones of the valve seating. If

this is not checked, the piston

cannot work properly.

The screen pipe is a filter, preventing sand and

mud entering the cylinder which could cause

damage to the seals.

Cylinder socket

DN65

Cylinder Body

(casing)

Valve seating

Valve Plate

Pump Bucket

Rubber seating

Cost of the cylinder: 1 150 000 Leones

Page 6: Kardia Hand Pump Guideline - Inter Aideinteraide.org/watsan/sl/wp-content/uploads/2015/08/Guideline_Kardi… · Kardia Hand Pump Guideline . 2 I. The Head Assembly You can dismantle

6

IV. The Cylinder (Kardia 65)

Pump Bucket

Valve seating

Valve Plate

Rubber seating

Sleeve

Screen Pipe

Rubber seating

Foot valve

Cylinder socket

DN65

Cylinder Body

(casing)

The difference between Kardia 65 and Kardia 2000:

-the piston is made up of 4 seals for Kardia 2000 and 5 for Kardia 65 (piston sleeve)

-the rubber seating on K2000 & K65 are different

-You need a reducer to tighten the screen pipe on K2000 while it is not necessary on K65