K Series
2
Selection table of RCCB's
SeriesSensitivity
(mA)Poles Type 16 25 40 63 80 100
Isolator
appl.
Add-on
devices
Rated
voltage
KB
30 2P A 240
4P A x x 240/415
Nominal current (A)
Selection table of RCBO's
SeriesSensitivity
(mA)Poles Type
Tripping
charact.6 10 16 20 25 32
Isolator
appl.
Add-on
devices
Rated
voltage
KDMA100
30 1P+N A C 240
Nominal current
(A)
KG Serie
s
3
Technical data of MCB's
Series KG60
Standards EN 60898
Tripping characteristics B, C
Nominal current A 6 - 63
Calibration temperature ºC 30
Number of poles (# mod) 1 / 2 / 3 / 4
Neutral pole protection yes
Nominal voltage Un AC 1P V 230/400
2P V 230
3P 4P V 400
DC 1P (1) V DC -
2P (in series) (1) V DC -
Frecuency Hz 50/60
Maximum service voltage Ubmax between two wires V 250
Minimum service voltage Ubmin V 12
Selectivity class (EN/IEC 60898-1) -
Isolator application EN/IEC 60947-2 -
Rated insulation voltage Pollution degree 2 V 500
Pollution degree 3 V 440
Impulse withstand test voltage kV 6
Insulation resistance MΩ 1000
Dielectric rigidity kV 2,5
Vibrations resistance (in x, y ,z direction) (EN/IEC 77/16,3) 3
Endurance electrical at Un, In 10000
mechanical 20000
Utilisation category (EN/IEC 60947-2)
Mounting position (for all devices): any except upside down any
Incoming top or bottom yes
Protection degree (according to UL94) IP20 / IP40
Self extinguish degree (according to UL94) V2
Tropicalisation (according to EN/IEC 60068-2 / DIN 40046) ºC/RH +55ºC/95% H.R.
Operating temperature ºC -25/+55
Storage temperature ºC -25/+55
Terminal capacity Rigid cabke min/max (top) mm² 1 / 25 or 2x10
Flexible cable min*/max (top mm² 0,75 / 25 or 2x10
Rigid cabke min/max (bottom) mm² 1 / 25 or 2x10
Flexible cable min*/max (bottom) mm² 0,75 / 25 or 2x10
(*Flexible cable 0,75/1/1,5 mm² with cable lug)
Torque Nm 4,5
Add-on devices Auxiliary contacts
(side add-on) Tele U -
Tele L -
Tele MP -
PBS -
Busbar systems Pin (top/bottom) yes / yes
Fork (top/bottom) - / yes
Accesories -
Dimensions (HxDxW) 86x68xW mm/mod. 18
Weight/mod. g 120
Package mod. 12
Approvals -
CE-marking yes
4
KG Series
Miniature Circuit Breakers (MCB) areintended for the protection or wiringinstallations against both overloads andshort-circuit in domestics or commercialwiring installations where operation ispossible by uninstructed people.
Characteristics according to EN/IEC 60898-1
Magnetic releaseAn electromagnet with plunger ensuresinstantaneous tripping in the event of short-circuit. The standard distinguishes threedifferent types, following the current forinstantaneous release: type B, C.
Thermal releaseThe release is insulated by a bimetal strip incase of overload. The standard defines therange of releases for specific overload values.Reference ambient temperatures is 30 ºC.
Icn (A)Test
currentTripping time Applications
B 3 x In 0,1 < t < 45s (In≤32A) Only for resistive loads such as:
0,1 < t < 90s (In>32A) - electrical heating
5 x In t < 0,1s - water heater
- stoves
C 5 x In 0,1 < t < 15s (In≤32A) Usual loads such as:
0,1 < t < 30s (In>32A) - lighting
10 x In t < 0,1s - socket-outlets
- small motors
Test current Tripping time
1,13 x In t ≥ 1h (In ≤ 63A)
t ≥ 2h (In > 63A)
1,45 x In t ≥ 1h (In ≤ 63A)
t ≥ 1h (In > 63A)
2,55 x In 1s > t > 60s (In ≤ 32A)
1s > t > 120s (In > 32A)
6
KB Serie
s Technical data of RCD's
Series KBD 2P KBP 4P
Standards EN/IEC 61008-1 EN/IEC 61008-1
Magnetic tripping characteristics - -
Residual tripping characteristics A A
Tripping time at IΔn Instantaneous ms < 40 < 40
Selective ms - -
Rated current A 40 40
Rated residual current IΔn mA 30 30
Calibration temperature ºC 30 30
Number of poles versus modules 1 1
Rated voltage Un 2P AC V 240
3P AC V - -
4P AC V 415
Frecuency Hz 50/60 50/60
Maximum service voltage Ubmax V 2P=265 4P=455
Minimum service voltage Ubmin V 2P=117 4P=205
Minimum voltage for leakage protection V Voltage independent Voltage independent
Power supply Top/Bottom Top/Bottom
Selectivity class (EN/IEC 60898-1) - -
Rated marking and breaking capacity (Im) A 500 (or 10xIn) 500 (or 10xIn)
Residual marking and breaking capacity (I∆ m) A 500 (or 10xIn) 500 (or 10xIn)
Conditional short-circuit capacity (Icn) A 10000 fuse 100A gLgG 10000 fuse 100A gLgG
Conditional residual short-circuit capacity (IΔ c) A 10000 fuse 100A gLgG 10000 fuse 100A gLgG
Rated Short-circuit capacity (Icn) A - -
Grid distance (safety distance between two devices) mm 35 35
Isolator application yes yes
Insulation degree Insulation voltage V (DC) 440 440
Shock voltage kV 6 6
Insulation resistance MΩ 1000 1000
Dielectric rigidity V 2500 2500
Shock resistance (in x, y, z direction) (EN/IEC 60077/16,3) 40g, 18 shocks 5 ms 40g, 18 shocks 5 ms
Vibrations resistance (in x, y ,z direction) (EN/IEC 77/16,3) 1,5g. 30 min, 0…80Hz 1,5g. 30 min, 0…80Hz
Endurance electrical at Un, In 10000 10000
mechanical at Un, In 20000 20000
Protection degree (outside/inside electrical enclosure with door) IP20 / IP40 IP20 / IP40
Self extinguish degree (according to UL94) V2 V2
Tropicalisation (according to EN/IEC 60068-2 / DIN 40046) ºC/RH +55ºC/95% H.R. +55ºC/95% H.R.
Pollution degree (acc. EN/IEC 60947-1) 3 3
Operating temperature ºC -25...+60 -25...+60
Storage temperature ºC -25...+70 -25...+70
Terminal capacity Rigid cabke min/max (top) mm² 1,5 / 25 1,5 / 50
Flexible cable min*/max (top mm² 1,5 / 25 1,5 / 35
Rigid cabke min/max (bottom) mm² 1,5 / 25 1,5 / 50
Flexible cable min*/max (bottom) mm² 1,5 / 25 1,5 / 35
(*Flexible cable 0,75/1/1,5 mm² with cable lug)
Torque Top/Bottom Nm 4/4 5/5
Add-on devices Auxiliary contacts
(side add-on) Tele U no yes
Tele L no yes
Tele MP no yes
PBS no yes
Busbar systems Pin (top/bottom) yes / yes yes / yes
Fork (top/bottom) - / yes yes / yes
# Poles 2 4
Dimensions (HxDxW) 86x68xW mm/mod. 36 72
Weight/mod. g 2P=250 4P=368
Package mod. 2P=1/6 4P=1/3
Approvals - -
CE-marking yes yes
KDM Serie
s Technical data of RCBO's
Series KDMA100
Standards EN/IEC 61009-1
Magnetic tripping characteristics C
Residual tripping characteristics A
Tripping time at IΔn Instantaneous ms < 40
Selective ms -
Rated current A 10,16
Rated residual current IΔn mA 30
Calibration temperature ºC 30
Number of poles versus modules 1
Rated voltage Un 2P AC V 230 (1P+N)
3P AC V -
4P AC V
Frecuency Hz 50/60
Maximum service voltage Ubmax V 255
Minimum service voltage Ubmin V 117
Minimum voltage for leakage protection V Voltage independent
Power supply Top/Bottom
Selectivity class (EN/IEC 60898-1) 3
Rated marking and breaking capacity (Im) A -
Residual marking and breaking capacity (I∆ m) A 6000
Conditional short-circuit capacity (Icn) A -
Conditional residual short-circuit capacity (IΔ c) A -
Rated Short-circuit capacity (Icn) A 10000
Grid distance (safety distance between two devices) mm 35
Isolator application yes
Insulation degree Insulation voltage V (DC) 440
Shock voltage kV 6
Insulation resistance MΩ 1000
Dielectric rigidity V 2500
Shock resistance (in x, y, z direction) (EN/IEC 60077/16,3) 40g, 18 shocks 5 ms
Vibrations resistance (in x, y ,z direction) (EN/IEC 77/16,3) 1,5g. 30 min, 0…80Hz
Endurance electrical at Un, In 10000
mechanical at Un, In 20000
Protection degree (outside/inside electrical enclosure with door) IP20 / IP40
Self extinguish degree (according to UL94) V2
Tropicalisation (according to EN/IEC 60068-2 / DIN 40046) ºC/RH +55ºC/95% H.R.
Pollution degree (acc. EN/IEC 60947-1) 3
Operating temperature ºC -25...+60
Storage temperature ºC -25...+70
Terminal capacity Rigid cabke min/max (top) mm² 1 / 25
Flexible cable min*/max (top mm² 1,5 / 16
Rigid cabke min/max (bottom) mm² 1 / 35
Flexible cable min*/max (bottom) mm² 1 / 25
Torque Top/Bottom Nm 3/4
Add-on devices Auxiliary contacts yes
(side add-on) Tele U yes
Tele L yes
Tele MP yes
Busbar systems Pin (top/bottom) yes / yes
Fork (top/bottom) - / yes
# Poles 1P+N
Dimensions (HxDxW) 86x68xW mm/mod. 36
Weight/mod. g 250
Package mod. 1/6
Approvals -
CE-marking yes