july 21, 2015 david r. pettijohn - planning.lacity.org · july 21, 2015 david r. pettijohn director...
TRANSCRIPT
Water Supply Assessments
LADWP Board Meeting July 21, 2015
David R. Pettijohn Director of Water Resources
Los Angeles Department of Water and Power
State Law Requirement
Water Code 10910-10915 – As part of CEQA, City is required to
prepare a Water Supply Assessment (WSA) for large developments.
– Determine if total projected water supplies available during normal, single dry, multiple dry years over a 20-year period will meet project’s demand, in addition to City’s future demands
2
Water Supply Assessment
• Identification of Water Supplies
• Detailed Project Description
• Calculation of Project’s Water Demand
• Compliance with current ordinances
• Determination of whether the Project’s water demand was included in the most recently adopted UWMP
• Statement of Findings
3
520000
570000
620000
670000
720000
770000
2015 2020 2025 2030 2035
Acre
-Fe
et
Year
Forecasted WSA Project Demand
Forecasted Demand
4
77%
23%
Future Demand Growth
When Would We Not
Recommend WSA Approval?
Water Code 10911 – Assess plans for acquiring additional
water supplies
Supplies Impacted by: – Loss of supply(s);
– Catastrophic disruption;
– Natural disaster;
– Regulatory / Environmental; or
– Drought Year Supply Shortage
6
11 Recycled Water
79 Local Groundwater
61 Los Angeles
Aqueduct
334 MWD
0
100
200
300
400
500
600
Projected 15/16 Supplies
Th
ou
sa
nd
Acre
-Fe
et
(TA
F)
7
Governor’s Executive Order (474 TAF)
Mayors ED5 (485 TAF)
Current Dry Year Supplies
7
Projects That Require a WSA
Water Code 10912 – Residential development > 500 dwelling
units
– Shopping center/ business establishment > 500,000 s.f.
– Commercial office building > 250,000 s.f.
– Hotel/Motel > 500 rooms
– Industrial development > 40 acres of land or 650,000 s.f. floor space
8
Water Demand Estimate
• Net Additional Water Demand = Proposed – Existing – Conservation
• Proposed Indoor Building Outdoor Landscaping Cooling Towers
• Existing Water Use Billing Records
• Conservation
Required by City Ordinances Additional Voluntary Recycled Water
9
Proposed Water Demand
• Indoor Building – Sewer Generation Factors (SGF)
• Cooling Towers • Outdoor Landscaping
– Model Water Efficient Landscape Ordinance
10
Required for Board Approval
Current Adopted UWMP
– Water demand projections based on Southern California Association of Governments (SCAG) demographic projections
Project Consistency with SCAG
City’s General Plan
– Community Plans: based on the SCAG data.
Determination of Adequate Supplies
13
WSA Findings
• Determination of sufficient water supplies to meet Project’s demand during normal, single dry, and multiple dry years for the next 25 years
• Determination of Project’s water demand falls within the City’s water demand growth projection
• Estimate of Project’s Additional Water Demand
14