july 21, 2015 david r. pettijohn - planning.lacity.org · july 21, 2015 david r. pettijohn director...

14
Water Supply Assessments LADWP Board Meeting July 21, 2015 David R. Pettijohn Director of Water Resources Los Angeles Department of Water and Power

Upload: lyxuyen

Post on 02-May-2018

221 views

Category:

Documents


1 download

TRANSCRIPT

Water Supply Assessments

LADWP Board Meeting July 21, 2015

David R. Pettijohn Director of Water Resources

Los Angeles Department of Water and Power

State Law Requirement

Water Code 10910-10915 – As part of CEQA, City is required to

prepare a Water Supply Assessment (WSA) for large developments.

– Determine if total projected water supplies available during normal, single dry, multiple dry years over a 20-year period will meet project’s demand, in addition to City’s future demands

2

Water Supply Assessment

• Identification of Water Supplies

• Detailed Project Description

• Calculation of Project’s Water Demand

• Compliance with current ordinances

• Determination of whether the Project’s water demand was included in the most recently adopted UWMP

• Statement of Findings

3

520000

570000

620000

670000

720000

770000

2015 2020 2025 2030 2035

Acre

-Fe

et

Year

Forecasted WSA Project Demand

Forecasted Demand

4

77%

23%

Future Demand Growth

Urban Water Management Plan

Supply Growth

5

Today

Future

When Would We Not

Recommend WSA Approval?

Water Code 10911 – Assess plans for acquiring additional

water supplies

Supplies Impacted by: – Loss of supply(s);

– Catastrophic disruption;

– Natural disaster;

– Regulatory / Environmental; or

– Drought Year Supply Shortage

6

11 Recycled Water

79 Local Groundwater

61 Los Angeles

Aqueduct

334 MWD

0

100

200

300

400

500

600

Projected 15/16 Supplies

Th

ou

sa

nd

Acre

-Fe

et

(TA

F)

7

Governor’s Executive Order (474 TAF)

Mayors ED5 (485 TAF)

Current Dry Year Supplies

7

Projects That Require a WSA

Water Code 10912 – Residential development > 500 dwelling

units

– Shopping center/ business establishment > 500,000 s.f.

– Commercial office building > 250,000 s.f.

– Hotel/Motel > 500 rooms

– Industrial development > 40 acres of land or 650,000 s.f. floor space

8

Water Demand Estimate

• Net Additional Water Demand = Proposed – Existing – Conservation

• Proposed Indoor Building Outdoor Landscaping Cooling Towers

• Existing Water Use Billing Records

• Conservation

Required by City Ordinances Additional Voluntary Recycled Water

9

Proposed Water Demand

• Indoor Building – Sewer Generation Factors (SGF)

• Cooling Towers • Outdoor Landscaping

– Model Water Efficient Landscape Ordinance

10

Slide

Water Use Factors

11

Slide

Demand Calculations

Required for Board Approval

Current Adopted UWMP

– Water demand projections based on Southern California Association of Governments (SCAG) demographic projections

Project Consistency with SCAG

City’s General Plan

– Community Plans: based on the SCAG data.

Determination of Adequate Supplies

13

WSA Findings

• Determination of sufficient water supplies to meet Project’s demand during normal, single dry, and multiple dry years for the next 25 years

• Determination of Project’s water demand falls within the City’s water demand growth projection

• Estimate of Project’s Additional Water Demand

14