p001lionberger.com/files/2016/12/aep-p-drawings.pdfwha josam #75000 series water hammer arrester,...

6
DATE REVISIONS DESIGN ARCHITECT PROJECT ARCHITECT NUMBER DATE PROJECT ENGINEER NOV 29, 2016 SHEET TITLE KEY PLAN SPECTRUM DESIGN PROJECT NO. 16056 GENERAL NOTES CHECKED BY DRAWN BY 10 CHURCH AVE SE, PLAZA SUITE 1 ROANOKE, VIRGINIA 24011 540.342.6001 J:\16056\Plumb\Dwg\16056_P001.dwg, Plotted By: trutledge, Plotted: Nov 28, 2016 - 2:58pm AEP ABINGDON ABINGDON, VA DCV DWR 11/29/16 TRANSMISSION FACILITY RENOVATION AND ADDITION RWM JDB TDR PLUMBING LEGEND AND SCHEDULES P001

Upload: phammien

Post on 12-May-2018

230 views

Category:

Documents


0 download

TRANSCRIPT

DATE

REVISIONS

DESIGN ARCHITECT

PROJECT ARCHITECT

NUMBER DATE

PROJECT ENGINEER

NOV 29, 2016

SHEET TITLE

KEY PLAN

SPECTRUM DESIGN PROJECT NO. 16056

GENERAL NOTES

CHECKED BY

DRAWN BY

10 CHURCH AVE SE, PLAZA SUITE 1 ROANOKE, VIRGINIA 24011 540.342.6001

J:\16056\P

lum

b\D

wg\16056_P

001.dw

g, P

lotted B

y: trutledge, P

lotted: N

ov 28, 2016 - 2:58pm

AEP ABINGDON

ABINGDON, VA

DCV

DWR

11/29/16

TRANSMISSION FACILITYRENOVATION AND ADDITION

RWM

JDB

TDR

PLUMBINGLEGEND ANDSCHEDULES

P001

AutoCAD SHX Text
DOMESTIC HOT WATER RECIRCULATING
AutoCAD SHX Text
DOMESTIC HOT WATER
AutoCAD SHX Text
DOMESTIC COLD WATER
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
BALANCING VALVE (MANUAL)
AutoCAD SHX Text
BALANCING VALVE (AUTOMATIC)
AutoCAD SHX Text
BALANCING COCK
AutoCAD SHX Text
UNION
AutoCAD SHX Text
FLEXIBLE PIPE CONNECTION
AutoCAD SHX Text
HOSE BIBBS (PLAN & ELEVATION)
AutoCAD SHX Text
STRAINER, STRAINER WITH DRAIN
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
POINT OF CONNECTION, NEW TO EXISTING
AutoCAD SHX Text
BACKFLOW PREVENTER
AutoCAD SHX Text
A
AutoCAD SHX Text
COMPRESSED AIR
AutoCAD SHX Text
EXISTING PIPE
AutoCAD SHX Text
213
AutoCAD SHX Text
ROOM NUMBER
AutoCAD SHX Text
EXISTING PIPE TO BE REMOVED
AutoCAD SHX Text
SPRINKLER HEAD
AutoCAD SHX Text
BRANCH CONNECTION - BOTTOM OF MAIN
AutoCAD SHX Text
BRANCH CONNECTION - SIDE OF MAIN
AutoCAD SHX Text
BRANCH CONNECTION - TOP OF MAIN
AutoCAD SHX Text
PIPE DOWN OR PIPE FROM BELOW
AutoCAD SHX Text
PIPE UP OR PIPE FROM ABOVE
AutoCAD SHX Text
DIRECTION OF FLOW
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CLEANOUT FLUSH WITH FLOOR
AutoCAD SHX Text
CLEANOUT BELOW FLOOR
AutoCAD SHX Text
SANITARY SEWER OR DRAIN
AutoCAD SHX Text
SANITARY VENT
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
LIMITS OF DEMOLITION
AutoCAD SHX Text
%%UNOTES
AutoCAD SHX Text
1. SIZE GIVEN ARE FOR FIXTURE ONLY. EXCEPTIONS, IF ANY, ARE SHOWN ON PLANS.
AutoCAD SHX Text
2. MOUNTING HEIGHT DIMENSIONS ARE TO FLOOD LEVEL RIM OF FIXTURE, UNLESS NOTED OTHERWISE.
AutoCAD SHX Text
LAV-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
MARK
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text
WATER CLOSET, HC
AutoCAD SHX Text
34
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
MOUNTING
AutoCAD SHX Text
1"
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
COLD
AutoCAD SHX Text
2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
4"
AutoCAD SHX Text
WASTE
AutoCAD SHX Text
2"
AutoCAD SHX Text
VENT
AutoCAD SHX Text
17
AutoCAD SHX Text
HEIGHT, IN
AutoCAD SHX Text
WATER, IN
AutoCAD SHX Text
SIZE, IN
AutoCAD SHX Text
SIZE, IN
AutoCAD SHX Text
HOT
AutoCAD SHX Text
WATER, IN
AutoCAD SHX Text
PLUMBING FIXTURE INSTALLATION SCHEDULE
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
SHOWER, HC
AutoCAD SHX Text
38-48 (NOTE 3)
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
3. MOUNTING HEIGHT DIMENSION FOR CONTROL IS MAXIMUM, SHALL BE LOCATED ABOVE THE GRAB BAR(S) AND NO MORE THAN
AutoCAD SHX Text
4. MOUNTING HEIGHT DIMENSION FOR WATER COOLER IS MAXIMUM TO LOWER SPOUT OUTLET.
AutoCAD SHX Text
UR-1
AutoCAD SHX Text
URINAL, HC
AutoCAD SHX Text
17
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
S-1
AutoCAD SHX Text
BREAK ROOM SINK
AutoCAD SHX Text
COUNTERTOP
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
27 INCHES FROM THE SEAT WALL.
AutoCAD SHX Text
WC-2SAME AS WC-1 BUT MOUNTED AS STANDARD HEIGHT.SAME AS WC-1 BUT MOUNTED AS STANDARD HEIGHT.
AutoCAD SHX Text
(EQUAL LAVATORY MANUFACTURERS INCLUDE KOHLER AND TOTO.)
AutoCAD SHX Text
SH-1AQUARIUS #G3636-SH MOLDED GELCOAT HANDICAPPED SHOWER ENCLOSURE, AQUARIUS #G3636-SH MOLDED GELCOAT HANDICAPPED SHOWER ENCLOSURE, 36" X 36" X 77-3/4", COLOR WHITE, WITH SMOOTH STAINLESS STEEL GRAB BARS, STAINLESS STEEL CURAIN ROD, STAINLESS STEEL RECESSED SOAP DISH,FOLD-UP SEAT. SYMMONS MODEL #1-25-FSB SAFETYMIX HANDICAPPED, ANTI-SCALD PRESSURE BALANCED VALVE WITH CHROME WALL PLATE, HAND HELD SHOWER HEAD, FLEXIBLE HOSE WITH SLIDE BAR, VACUUM BREAKER, ADJUSTABLE LIMIT STOP SET TO 110 DEG F. AND 1/2" INLET/OUTLET, HOT AND COLD WATER INDICATORS, 2.0 GPM MAXIMUM. RECESS UNIT IN SLAB FOR EQUAL TO OR LESS THAN 1/2" THRESHOLD. PROVIDE BRASS SWIVEL #FP-1E-BRASS ON HAND HELD SHOWER HEAD.
AutoCAD SHX Text
FD-1JOSAM #30000-5A-2-VP FLOOR DRAIN, SATIN FINISH BRONZE TOP, JOSAM #30000-5A-2-VP FLOOR DRAIN, SATIN FINISH BRONZE TOP, ADJUSTABLE STRAINER, SECURED GRATE, TRAP GUARD INSERT.
AutoCAD SHX Text
HWRP-1BELL & GOSSETT #NBF-8S/LW-103257LF LEAD FREE BRONZE BELL & GOSSETT #NBF-8S/LW-103257LF LEAD FREE BRONZE CIRCULATING PUMP, 115 VOLT/1PH, 0.38A, 3 GPM @ 5 FT. HEAD, ALL BRONZE CONSTRUCTION, CONTROLLED BY AQUASTAT.
AutoCAD SHX Text
(EQUAL SHOWER MANUFACTURERS INCLUDE AQUATIC BATH AND FLORESTONE.) (EQUAL FAUCET MANUFACTURERS INCLUDE DELTA AND MOEN.)
AutoCAD SHX Text
(EQUAL PUMP MANUFACTURERS INCLUDE ARMSTRONG AND TACO.)
AutoCAD SHX Text
TV-1LAWLER #801 THERMOSTATIC MIXING VALVE WITH UNION END STOP LAWLER #801 THERMOSTATIC MIXING VALVE WITH UNION END STOP AND CHECK INLETS WITH REMOVABLE STAINLESS STEEL STRAINERS. PROVIDE WITH DIAL THERMOMETER AND SHUT-OFF VALVE ON OUTLET. PROVIDE VALVE INSIDE OF BOX. 25 GPM CAPACITY @10 PSI PD. SET AT 110 DEGREE F LEAVING WATER TEMPERATURE.
AutoCAD SHX Text
WHAJOSAM #75000 SERIES WATER HAMMER ARRESTER, SIZE AND LOCATION IN JOSAM #75000 SERIES WATER HAMMER ARRESTER, SIZE AND LOCATION IN ACCORDANCE W/ P.D.I. STD. WH-201. STAINLESS STEEL SHELL, STAINLESS STEEL BELLOWS TYPE, FACTORY PRE-CHARGED WITH THREADED PLUG.
AutoCAD SHX Text
WC-2
AutoCAD SHX Text
WATER CLOSET
AutoCAD SHX Text
1"
AutoCAD SHX Text
-
AutoCAD SHX Text
4"
AutoCAD SHX Text
2"
AutoCAD SHX Text
15
AutoCAD SHX Text
LAV-2
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
1/2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
COUNTERTOP
AutoCAD SHX Text
WC-1KOHLER KINGSTON K-4325 ELONGATED VITREOUS CHINA HANDICAP WATER KOHLER KINGSTON K-4325 ELONGATED VITREOUS CHINA HANDICAP WATER CLOSET (FLUSH VALVE, 1-1/2 INCH TOP SPUD, WALL MOUNTED, 1.28 GAL/FLUSH, SIPHON JET) WITH K-13517-CP CHROME PISTON MANUAL FLUSH VALVE; CHURCH #295C ELONGATED OPEN FRONT SEAT, SOLID RING PIPE SUPPORT, BOLT CAPS AND JOSAM #12000 SERIES WALL CARRIER.AND JOSAM #12000 SERIES WALL CARRIER.
AutoCAD SHX Text
(EQUAL WATER CLOSET MANUFACTURERS INCLUDE KOHLER AND AMERICAN STANDARD.) (EQUAL SEAT MANUFACTURERS INCLUDE BEMIS AND OLSONITE.) (EQUAL FLUSH VALVE MANUFACTURERS INCLUDE SLOAN AND ZURN.) (EQUAL CLOSET CARRIER MANUFACTURERS INCLUDE JAY R. SMITH AND MIFAB.)
AutoCAD SHX Text
WH-1WATTS #HY-725-3 NON-FREEZE KEY OPERATED WALL HYDRANT WITH WATTS #HY-725-3 NON-FREEZE KEY OPERATED WALL HYDRANT WITH STAINLESS STEEL BOX AND DOOR, ALL BRONZE WORKING PARTS, WITH INTEGRAL VACUUM BREAKER.
AutoCAD SHX Text
WH-2WATTS #HY-330 MODERATE CLIMATE KEY OPERATED WALL HYDRANT (FOR WATTS #HY-330 MODERATE CLIMATE KEY OPERATED WALL HYDRANT (FOR INDOOR USE ONLY) WITH NICKEL BRONZE BOX AND DOOR, INTEGRAL VACUUM BREAKER.
AutoCAD SHX Text
(EQUAL STEEL SINK MANUFACTURERS INCLUDE JUST AND REVERE.) (EQUAL FAUCET MANUFACTURERS INCLUDE CHICAGO, SYMMONS AND T&S BRASS.)
AutoCAD SHX Text
UR-1 AMERICAN STANDARD WASHBROOK #6590.001 VITREOUS CHINA HANDICAP URINAL (FLUSH VALVE- 3/4" TOP SPUD, WALL MTD., 0.125 GAL./FLUSH) WASHOUT; TOTO ECOPOWER TEU1N HARDWIRED CHROME SOLENOID FLUSH VALVE AND SOLID RING PIPE SUPPORT. PROVIDE JOSAM #17800 SERIES CARRIER.
AutoCAD SHX Text
(EQUAL URINAL MANUFACTURERS INCLUDE KOHLER AND AMERICAN STANDARD.) (EQUAL FLUSH VALVE MANUFACTURERS INCLUDE SLOAN AND TOTO.)
AutoCAD SHX Text
LAV-2 AMERICAN STANDARD RONDALYN #0491.019 DROP IN HANDICAP LAVATORY, VITREOUS CHINA, 4" CENTERS; ZURN AQUA-FIT #Z6955-XL-S, 4" CENTERSET HARDWIRED SENSOR FAUCET W/ CHROME GRID STRAINER DRAIN AND W/CHROME GRID STRAINER, VANDALPROOF 0.5 GPM AERATOR, CHROME OFFSET P-TRAP WITH CLEANOUT & LOOSE-KEYS. PROVIDE TRUEBRO #102W PRE-MOLDED INSULATION KIT INSULATING BOTH SUPPLIES AND DRAIN. PROVIDE UNDER COUNTER MIXING VALVE EQUAL TO SLOAN MIX-60A AND SET FOR 100°F. PROVIDE P6000-HW6 POWER CONVERTER TO OPERATE TWOFAUCETS.
AutoCAD SHX Text
LAV-1AMERICAN STANDARD #0355.012 LUCERNE WALL HUNG LAVATORY, VITREOUS AMERICAN STANDARD #0355.012 LUCERNE WALL HUNG LAVATORY, VITREOUS CHINA, 4" CENTERS; ZURN AQUA-FIT #Z6955-XL-S, 4" CENTERSET HARDWIRED SENSOR FAUCET W/ CHROME GRID STRAINER DRAIN, CHROME P-TRAP AND LOOSE KEY STOPS. PROVIDE WITH UNDER-LAV MIXING VALVE EQUAL TO SLOAN MIX-60A AND SET FOR 100 DEG F.
AutoCAD SHX Text
EWC-1ELKAY #LZSVR8 SINGLE STATION ELECTRIC HANDICAP WATER COOLER, ELKAY #LZSVR8 SINGLE STATION ELECTRIC HANDICAP WATER COOLER, STAINLESS STEEL BASIN WITH STAINLESS STEEL CLADDINT, FRONT AND SIDE PRESS BARS, LEAD FREE WORKING COMPONENTS; 8.0 GPH CAPACITY, 120V, 5.0 AMP.
AutoCAD SHX Text
BFP BACKFLOW PREVENTER BACKFLOW PREVENTER CB CATCH BASIN CATCH BASIN CO CLEAN-OUT CLEAN-OUT COND CONDENSATE CONDENSATE CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT CW COLD WATER COLD WATER E EXISTING EXISTING EWC ELECTRIC WATER COOLER ELECTRIC WATER COOLER FD FLOOR DRAIN FLOOR DRAIN HW HOT WATER HOT WATER HWR HOT WATER RETURN HOT WATER RETURN HWRP HOT WATER RECIRCULATING PUMP HOT WATER RECIRCULATING PUMP LAV LAVATORY LAVATORY PRV PRESSURE REDUCING VALVE PRESSURE REDUCING VALVE PVC POLYVINYL CHLORIDE POLYVINYL CHLORIDE SAN SANITARY SANITARY UR URINAL URINAL V VENT VENT VTR VENT-THRU-ROOF VENT-THRU-ROOF W WASTE WASTE WC WATER CLOSET WATER CLOSET WH WALL HYDRANT WALL HYDRANT CMU CONCRETE MASONRY UNIT CONCRETE MASONRY UNIT EWC ELECTRIC WATER COOLERELECTRIC WATER COOLER
AutoCAD SHX Text
LEGEND
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
PLUMBING EQUIPMENT SCHEDULE
AutoCAD SHX Text
S-1ELKAY LUSTERTONE #LRAD-1919 STAINLESS STEEL SINGLE BOWL HANDICAP ELKAY LUSTERTONE #LRAD-1919 STAINLESS STEEL SINGLE BOWL HANDICAP SINK WITH REAR CENTERED DRAIN, 19-1/2" LONG, 19" WIDE, 6" DEPTH AND THREE HOLE FAUCET MOUNT. SYMMONS #S-254-LWG CHROME FAUCET, GOOSENECK SPOUT AND WRIST BLADE HANDLES, 1.5 GPM VANDALPROOF AERATOR. PROVIDE TRUEBRO #102W PRE-MOLDED INSULATION ON BOTH WATER SUPPLIES AND DRAIN IF SINK PIPING IS EXPOSED.
AutoCAD SHX Text
SH-2AQUARIUS #G3679-SH MOLDED GELCOAT SHOWER ENCLOSURE, 36" X 36" X AQUARIUS #G3679-SH MOLDED GELCOAT SHOWER ENCLOSURE, 36" X 36" X 77-3/4", COLOR WHITE, STAINLESS STEEL CURTAIN ROD, MOLDED SOAP DISH. SYMMONS MODEL 1-100 SAFETYMIX, ANTI-SCALD PRESSURE BALANCED VALVE WITH CHROME WALL PLATE, AJUSTABLE SPRAY SHOWERHEAD, VACUUM BREAKER, ADJUSTABLE LIMIT STOP SET TO 110 DEG F. AND 1/2" INLET/OUTLET, HOT AND COLD WATER INDICATORS, 2.0 GPM MAXIMUM.
AutoCAD SHX Text
GENERAL PLUMBING NOTES: CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS. PIPE ROUTING SHOWN IS SCHEMATIC IN NATURE AND IS NOT INTENDED TO INDICATE EXACT LOCATION OF PIPING AND VALVES. CONTRACTOR SHALL PROVIDE ANY ADDITIONAL FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN PROPER CLEARANCES. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS BEFORE PERFORMING ANY WORK. THE EXISTING PLUMBING SYSTEMS HAVE BEEN SHOWN TO THE EXTENT KNOWN AND WHERE UNDERSTOOD TO EXIST. COORDINATE DEMOLITION OF PIPING SYSTEMS PRIOR TO PERFORMING DEMOLITION. COORDINATE WITH ALL TRADES AND POTENTIAL CONSTRUCTION OBSTRUCTIONS AND ROUTE PIPING TO AVOID INTERFERENCE. CONCEAL PIPING ABOVE CEILINGS, WITHIN WALLS OR CHASES (EXCEPT UTILITY TYPE ROOMS) OR AS SPECIFICALLY NOTED. PROVIDE ACCESS PANELS TO ALL VALVES LOCATED WITHIN CHASES OR NON-ACCESSIBLE CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS OF FIXTURE LOCATIONS AND MOUNTING HEIGHTS. PROVIDE FIXED AIR GAPS ON ALL INDIRECT WASTE CONNECTIONS. PROVIDE CLEANOUTS FOR SANITARY AND STORM PIPING AS INDICATED ON DRAWINGS AND AS REQUIRED BY CODE. INSTALL HOSE BIBBS AND WALL HYDRANTS 18 INCHES AFF UNLESS OTHERWISE DIRECTED. PROVIDE WATER HAMMER ARRESTORS FOR ALL PLUMBING FIXTURES OR BATTERY OF FIXTURES THAT UTILIZE QUICK-CLOSING VALVES. TERMINATE PLUMBING VENTS AT LEAST 10 FEET FROM VENTILATION INTAKES AND AT LEAST 3 FEET ABOVE WINDOWS, DOORS AND OTHER OPENINGS. PROVIDE NEW FAUCET FOR EXISTING UTILITY SINK AS INDICATED IN SCHEDULE AS FAUCET-1..
AutoCAD SHX Text
EX-1AMTROL THERM-X-TROL MODEL #ST-12 THERMAL EXPANSION TANK, 4.4 AMTROL THERM-X-TROL MODEL #ST-12 THERMAL EXPANSION TANK, 4.4 GALLONS MAXIMUM ACCEPTANCE VOLUME, BUTYL DIAPHRAGM, FACTORY PRE-CHARGED AT 40 PSI.
AutoCAD SHX Text
UR-2SAME AS UR-1 BUT MOUNTED AS STANDARD HEIGHT.SAME AS UR-1 BUT MOUNTED AS STANDARD HEIGHT.
AutoCAD SHX Text
-
AutoCAD SHX Text
UR-1
AutoCAD SHX Text
URINAL
AutoCAD SHX Text
24
AutoCAD SHX Text
3/4"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
1-1/2"
AutoCAD SHX Text
FAUCET-1 AMERICAN STANDARD 8350.243SERVICE SINK FAUCET, WITH BUILT-IN VACUUM BREAKER, CAST BRASS SPOUT WITH THREADED HOSE CONNECTION, ROUGH CHROME FINISH, INTEGRAL SUPPLY STOPS. FIELD VERIFY DIMENSIONS PRIOR TO SHOP DRAWING SUBMISSION.
AutoCAD SHX Text
BFP-1WATTS #LF009 (1" OR LESS) REDUCED PRESSURE ZONE BACKFLOW WATTS #LF009 (1" OR LESS) REDUCED PRESSURE ZONE BACKFLOW PREVENTER, ASSE 1013; BRONZE BODY WITH TWO INDEPENDENTLY WITH TWO INDEPENDENTLY OPERATING, SPRING LOADED CHECK VALVES, DIAPHRAGM TYPE DIFFERENTIAL PRESSURE RELIEF VALVE, NON THREADED OUTLET, ASSEMBLED WITH TWO GATE VALVES, STRAINER AND TEST COCKS. PROVIDE WITH AIR GAP FITTING.

WD

1

1

DATE

REVISIONS

DESIGN ARCHITECT

PROJECT ARCHITECT

NUMBER DATE

PROJECT ENGINEER

NOV 29, 2016

SHEET TITLE

KEY PLAN

SPECTRUM DESIGN PROJECT NO. 16056

GENERAL NOTES

CHECKED BY

DRAWN BY

10 CHURCH AVE SE, PLAZA SUITE 1 ROANOKE, VIRGINIA 24011 540.342.6001

J:\16056\P

lum

b\D

wg\16056_P

101.dw

g, P

lotted B

y: trutledge, P

lotted: N

ov 28, 2016 - 2:58pm

AEP ABINGDON

ABINGDON, VA

DCV

DWR

11/29/16

TRANSMISSION FACILITYRENOVATION AND ADDITION

RWM

JDB

TDR

PLUMBINGBELOW GRADEDEMOLITION PLAN

PD101

1

AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
2" WATER ENTRANCE TO REMAIN
AutoCAD SHX Text
(E)EWC TO REMAIN
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)SANITARY TO REMAIN
AutoCAD SHX Text
(E)SANITARY TO REMAIN
AutoCAD SHX Text
(E)SERVICE SINK TO REMAIN
AutoCAD SHX Text
(E)4"W
AutoCAD SHX Text
(E)4"W
AutoCAD SHX Text
4"W
AutoCAD SHX Text
FOR CONTINUATION
AutoCAD SHX Text
4"W
AutoCAD SHX Text
CO
AutoCAD SHX Text
REFER TO CIVIL
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
16'
AutoCAD SHX Text
8'
AutoCAD SHX Text
8'
AutoCAD SHX Text
4'
AutoCAD SHX Text
0
AutoCAD SHX Text
%%UBELOW GRADE PLUMBING
AutoCAD SHX Text
SCALE: 1/8"=1'-0"
AutoCAD SHX Text
PRIOR TO PERFORMING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS. ALL BELOW GRADE PIPING HAS BEEN SHOWN AS A REPRESENTATION OF THE LIKELY LOCATION OF THE SANITARY SYSTEM. ACTUAL LOCATION OF EXISTING BELOW GRADE SANITARY PIPING HAS NOT BEEN VERIFIED. CONTRACTOR IS ALLOWED TO RE-USE EXISTING SANITARY PIPING SHOWN TO BE DEMOLISHED OR CAPPED. IN AREAS OF DEMOLITION, REMOVE ALL VENT PIPING BELOW ROOF. RE-USE EXISTING VENT THROUGH ROOF PENETRATIONS. CAP AND SEAL ANY UNUSED VENTS THROUGH ROOF.
AutoCAD SHX Text
SHEET NOTES: REMOVE FLOOR DRAIN AND CAP SANITARY.

WD

11

1

5

6

17

8

9

10

WD

3

2

4

DATE

REVISIONS

DESIGN ARCHITECT

PROJECT ARCHITECT

NUMBER DATE

PROJECT ENGINEER

NOV 29, 2016

SHEET TITLE

KEY PLAN

SPECTRUM DESIGN PROJECT NO. 16056

GENERAL NOTES

CHECKED BY

DRAWN BY

10 CHURCH AVE SE, PLAZA SUITE 1 ROANOKE, VIRGINIA 24011 540.342.6001

J:\16056\P

lum

b\D

wg\16056_P

102.dw

g, P

lotted B

y: trutledge, P

lotted: N

ov 28, 2016 - 2:59pm

AEP ABINGDON

ABINGDON, VA

DCV

DWR

11/29/16

TRANSMISSION FACILITYRENOVATION AND ADDITION

RWM

JDB

TDR

PLUMBINGABOVE GRADEDEMOLITION PLAN

PD102

1

2

3

4

5

6

7

8

9

10

AutoCAD SHX Text
(E)BUILDING CW WATER MAIN ENTRANCE, WITH STRAINER, PRV AND BACKFLOW PREVENTER
AutoCAD SHX Text
(E)EWC
AutoCAD SHX Text
(E)2"CW
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)ICEMAKER AND FILTRATION SYSTEM
AutoCAD SHX Text
(E)1/2"CW
AutoCAD SHX Text
(E)3/4"CW
AutoCAD SHX Text
(E)1/2"CW TO EWC
AutoCAD SHX Text
SEE ENLARGED JANITORS CLOSET THIS SHEET
AutoCAD SHX Text
(E)3/4" COND. FROM MINI SPLIT TO REMAIN
AutoCAD SHX Text
(E)DRAIN FROM WASHER TO REMAIN
AutoCAD SHX Text
(E)SERVICE SINK TO REMAIN
AutoCAD SHX Text
1/2"HW TO WASHER
AutoCAD SHX Text
(E)1/2"CW TO WASHER TO REMAIN
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
16'
AutoCAD SHX Text
8'
AutoCAD SHX Text
8'
AutoCAD SHX Text
4'
AutoCAD SHX Text
0
AutoCAD SHX Text
%%UDEMOLITION PLAN
AutoCAD SHX Text
SCALE: 1/8"=1'-0"
AutoCAD SHX Text
PRIOR TO PERFORMING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS. ALL BELOW GRADE PIPING HAS BEEN SHOWN AS A REPRESENTATION OF THE LIKELY LOCATION OF THE SANITARY SYSTEM. ACTUAL LOCATION OF EXISTING BELOW GRADE SANITARY PIPING HAS NOT BEEN VERIFIED. CONTRACTOR IS ALLOWED TO RE-USE EXISTING SANITARY PIPING SHOWN TO BE DEMOLISHED OR CAPPED. IN AREAS OF DEMOLITION, REMOVE ALL VENT PIPING BELOW ROOF. RE-USE EXISTING VENT THROUGH ROOF PENETRATIONS. CAP AND SEAL ANY UNUSED VENTS THROUGH ROOF.
AutoCAD SHX Text
SHEET NOTES: REMOVE PLUMBING FIXTURES IN SHOWER/TOILET/LOCKERS ROOM AS INDICATED, INCLUDING SHOWERS, LAVATORIES, TOILETS, URINALS AND FLOOR DRAINS. CAP SANITARY PIPING AT FLOOR. REMOVE VENT PIPING ABOVE CEILING. EXISTING VENTS THROUGH ROOF SHALL REMAIN AS EXISTING FOR RE-USE WITH NEW WORK. REMOVE EXISTING PVC DRAIN FROM WASHING MACHINE WHERE DRAIN PIPING PENETRATES CMU WALL. CAP END FOR RE-USE WITH NEW WORK. AS REQUIRED TO ACCOMODATE DEMOLITION OF CMU WALL, REMOVE EXISTING CONDENSATE DRAIN FROM DUCTLESS HVAC UNIT IN ADJACENT IT ROOM. CAP END FOR RE-USE WITH NEW WORK. REMOVE EXISTING ELECTRIC WATER HEATER. COORDINATE WITH REMOVAL OF ADJACENT ELECTRICAL DISCONNECT. EXISTING VENT THROUGH ROOF TO REMAIN. RE-USE WITH NEW WORK. DEMOLISH ALL DOMESTIC HOT WATER PIPING, VALVES AND INSULATION. DEMOLISH ALL COLD WATER PIPING, VALVES AND INSULATION BEYOND THIS POINT. MAIN SERVICE VALVES, STRAINER, PRESSURE REDUCING VALVE AND BACKFLOW PREVENTER TO REMAIN AS EXISTING. ICE MACHINE AND FILTRATION SYSTEM TO REMAIN AS EXISTING. (E)EWC TO REMAIN. REPLACE FILTER AS PART OF WORK.
AutoCAD SHX Text
%%UENLARGED JANITORS CLOSET
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
6'
AutoCAD SHX Text
4'
AutoCAD SHX Text
2'
AutoCAD SHX Text
2'
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
8'
AutoCAD SHX Text
4'
AutoCAD SHX Text
0
AutoCAD SHX Text
(E)FD TO REMAIN
AutoCAD SHX Text
(E)3/4"CW
AutoCAD SHX Text
REMOVE AND CAP HW TO WASHER

WD

DATE

REVISIONS

DESIGN ARCHITECT

PROJECT ARCHITECT

NUMBER DATE

PROJECT ENGINEER

NOV 29, 2016

SHEET TITLE

KEY PLAN

SPECTRUM DESIGN PROJECT NO. 16056

GENERAL NOTES

CHECKED BY

DRAWN BY

10 CHURCH AVE SE, PLAZA SUITE 1 ROANOKE, VIRGINIA 24011 540.342.6001

J:\16056\P

lum

b\D

wg\16056_P

101.dw

g, P

lotted B

y: trutledge, P

lotted: N

ov 28, 2016 - 2:58pm

AEP ABINGDON

ABINGDON, VA

DCV

DWR

11/29/16

TRANSMISSION FACILITYRENOVATION AND ADDITION

RWM

JDB

TDR

PLUMBINGBELOW GRADEFLOOR PLAN

P101

AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
2" WATER ENTRANCE TO REMAIN
AutoCAD SHX Text
(E)EWC TO REMAIN
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
4"W
AutoCAD SHX Text
2"W
AutoCAD SHX Text
SEE ENLARGED TOILET PLAN THIS SHEET
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)SANITARY TO REMAIN
AutoCAD SHX Text
(E)SANITARY TO REMAIN
AutoCAD SHX Text
(E)SERVICE SINK TO REMAIN
AutoCAD SHX Text
(E)4"W
AutoCAD SHX Text
2"W
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
S-1
AutoCAD SHX Text
2"V UP
AutoCAD SHX Text
4"W
AutoCAD SHX Text
FOR CONTINUATION
AutoCAD SHX Text
4"W
AutoCAD SHX Text
CO
AutoCAD SHX Text
REFER TO CIVIL
AutoCAD SHX Text
3"W
AutoCAD SHX Text
4"W
AutoCAD SHX Text
1 1/2"V UP
AutoCAD SHX Text
LAV-1
AutoCAD SHX Text
UR-2
AutoCAD SHX Text
WC-2
AutoCAD SHX Text
LAV-2
AutoCAD SHX Text
4"W
AutoCAD SHX Text
3"W
AutoCAD SHX Text
2"W
AutoCAD SHX Text
FD-1, 2", 2"
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
FD-1, 2", 2"
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
FD-1, 2", 2"
AutoCAD SHX Text
4"W
AutoCAD SHX Text
4"W
AutoCAD SHX Text
SH-2
AutoCAD SHX Text
SH-2
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
2"V UP
AutoCAD SHX Text
SH-2
AutoCAD SHX Text
2"V
AutoCAD SHX Text
2"W
AutoCAD SHX Text
2"V UP
AutoCAD SHX Text
2"V UP
AutoCAD SHX Text
LAV-1
AutoCAD SHX Text
UR-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
4"W
AutoCAD SHX Text
4"W
AutoCAD SHX Text
2"W
AutoCAD SHX Text
2"W
AutoCAD SHX Text
4"W
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
A
AutoCAD SHX Text
FOR CONTINUATION
AutoCAD SHX Text
REFER TO CIVIL
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
16'
AutoCAD SHX Text
8'
AutoCAD SHX Text
8'
AutoCAD SHX Text
4'
AutoCAD SHX Text
0
AutoCAD SHX Text
6'
AutoCAD SHX Text
4'
AutoCAD SHX Text
2'
AutoCAD SHX Text
2'
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
8'
AutoCAD SHX Text
4'
AutoCAD SHX Text
0
AutoCAD SHX Text
%%UFLOOR PLAN
AutoCAD SHX Text
SCALE: 1/8"=1'-0"
AutoCAD SHX Text
%%UENLARGED TOILET PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
PRIOR TO PERFORMING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS. ALL BELOW GRADE PIPING HAS BEEN SHOWN AS A REPRESENTATION OF THE LIKELY LOCATION OF THE SANITARY SYSTEM. ACTUAL LOCATION OF EXISTING BELOW GRADE SANITARY PIPING HAS NOT BEEN VERIFIED. CONTRACTOR IS ALLOWED TO RE-USE EXISTING SANITARY PIPING SHOWN TO BE DEMOLISHED OR CAPPED. IN AREAS OF DEMOLITION, REMOVE ALL VENT PIPING BELOW ROOF. RE-USE EXISTING VENT THROUGH ROOF PENETRATIONS. CAP AND SEAL ANY UNUSED VENTS THROUGH ROOF.

WD

6

10

WD

2

3

4

5

DATE

REVISIONS

DESIGN ARCHITECT

PROJECT ARCHITECT

NUMBER DATE

PROJECT ENGINEER

NOV 29, 2016

SHEET TITLE

KEY PLAN

SPECTRUM DESIGN PROJECT NO. 16056

GENERAL NOTES

CHECKED BY

DRAWN BY

10 CHURCH AVE SE, PLAZA SUITE 1 ROANOKE, VIRGINIA 24011 540.342.6001

J:\16056\P

lum

b\D

wg\16056_P

102.dw

g, P

lotted B

y: trutledge, P

lotted: N

ov 28, 2016 - 2:59pm

AEP ABINGDON

ABINGDON, VA

DCV

DWR

11/29/16

TRANSMISSION FACILITYRENOVATION AND ADDITION

RWM

JDB

TDR

PLUMBINGABOVE GRADEFLOOR PLAN

P102

1

2

3

4

5

6

AutoCAD SHX Text
(E)BUILDING CW WATER MAIN ENTRANCE, WITH STRAINER, PRV AND BACKFLOW PREVENTER
AutoCAD SHX Text
(E)VTR
AutoCAD SHX Text
1 1/2"V
AutoCAD SHX Text
(E)EWC
AutoCAD SHX Text
1 1/2"CW, 1"HW
AutoCAD SHX Text
1"CW, 3/4"HW
AutoCAD SHX Text
(E)2"CW
AutoCAD SHX Text
1 1/4"HW
AutoCAD SHX Text
3/4"HWR
AutoCAD SHX Text
1/2"CW, 1/2"HW
AutoCAD SHX Text
S-1
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
SEE ENLARGED TOILET PLAN THIS SHEET
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)FD
AutoCAD SHX Text
(E)ICEMAKER AND FILTRATION SYSTEM
AutoCAD SHX Text
(E)1/2"CW
AutoCAD SHX Text
(E)3/4"CW
AutoCAD SHX Text
WH-1
AutoCAD SHX Text
WH-1
AutoCAD SHX Text
3/4"CW
AutoCAD SHX Text
3/4"CW
AutoCAD SHX Text
1 1/2"CW
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
(E)1/2"CW TO EWC
AutoCAD SHX Text
SEE ENLARGED JANITORS CLOSET THIS SHEET
AutoCAD SHX Text
1"CW
AutoCAD SHX Text
NEW 1"CW UNDERGROUND
AutoCAD SHX Text
NEW BACK FLOW PREVENTER BFP-1BFP-1
AutoCAD SHX Text
UR-1
AutoCAD SHX Text
WC-2
AutoCAD SHX Text
LAV-2
AutoCAD SHX Text
3/4"CW, 3/4"HW
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
2"V
AutoCAD SHX Text
1 1/2"CW, 1"HW
AutoCAD SHX Text
3/4"HWR
AutoCAD SHX Text
1/2"CW, HW
AutoCAD SHX Text
3/4"HW, 1"CW
AutoCAD SHX Text
SH-2
AutoCAD SHX Text
SH-2
AutoCAD SHX Text
SH-1
AutoCAD SHX Text
WH-2
AutoCAD SHX Text
WH-2
AutoCAD SHX Text
WH-1
AutoCAD SHX Text
UR-2
AutoCAD SHX Text
LAV-1
AutoCAD SHX Text
LAV-1
AutoCAD SHX Text
WC-1
AutoCAD SHX Text
WH-2
AutoCAD SHX Text
%%UWHA
AutoCAD SHX Text
%%UWHA
AutoCAD SHX Text
%%UWHA
AutoCAD SHX Text
%%UWHA
AutoCAD SHX Text
SH-2
AutoCAD SHX Text
WHA
AutoCAD SHX Text
3/4"HWR
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
HWRP-1
AutoCAD SHX Text
TV-1
AutoCAD SHX Text
DWH-1
AutoCAD SHX Text
(E)1/2"CW TO WASHER TO REMAIN
AutoCAD SHX Text
1/2"HW TO WASHING MACHINE
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
A
AutoCAD SHX Text
1/8" = 1'-0"
AutoCAD SHX Text
16'
AutoCAD SHX Text
8'
AutoCAD SHX Text
8'
AutoCAD SHX Text
4'
AutoCAD SHX Text
0
AutoCAD SHX Text
6'
AutoCAD SHX Text
4'
AutoCAD SHX Text
2'
AutoCAD SHX Text
2'
AutoCAD SHX Text
1/4" = 1'-0"
AutoCAD SHX Text
8'
AutoCAD SHX Text
4'
AutoCAD SHX Text
0
AutoCAD SHX Text
%%UFLOOR PLAN
AutoCAD SHX Text
SCALE: 1/8"=1'-0"
AutoCAD SHX Text
%%UENLARGED TOILET PLAN
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
%%UENLARGED JANITORS CLOSET
AutoCAD SHX Text
SCALE: 1/4"=1'-0"
AutoCAD SHX Text
PRIOR TO PERFORMING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ACTUAL CONDITIONS. ALL EXISTING BELOW GRADE PIPING HAS BEEN SHOWN AS A REPRESENTATION OF THE LIKELY LOCATION OF THE SANITARY SYSTEM. ACTUAL LOCATION OF EXISTING BELOW GRADE SANITARY PIPING HAS NOT BEEN VERIFIED. CONTRACTOR IS ALLOWED TO RE-USE EXISTING SANITARY PIPING SHOWN TO BE DEMOLISHED OR CAPPED. IN AREAS OF DEMOLITION, REMOVE ALL VENT PIPING BELOW ROOF. RE-USE EXISTING VENT THROUGH ROOF PENETRATIONS. CAP AND SEAL ANY UNUSED VENTS THROUGH ROOF.
AutoCAD SHX Text
SHEET NOTES: PROVIDE NEW FILTER FOR EXISTING WATER COOLER. PROVIDE NEW ELECTRIC WATER HEATER, TEMPERATURE MIXING VALVE AND RECIRCULATION PUMP. REFER TO DETAIL. EXISTING SERVICE SINK TO REMAIN. CONTRACTOR SHALL RE-FURBISH AND CLEAN SERVICE SINK BY REMOVING AND REPLACING THE FAUCET AND CLEANING THE DRAIN STRAINER. PAINT P-TRAP AND SUPPORT ASSEMBLY FOR SINK. PROVIDE GENERAL OVERALL CLEANING. PROVIDE NEW DRAIN FROM WASHING MACHINE WHERE DRAIN PIPING PENTRATES CMU WALL. PROVIDE NEW CONDENSATE DRAIN FROM DUCTLESS HVAC UNIT IN ADJACENT IT ROOM. REUSE EXISTING VENT THROUGH ROOF.
AutoCAD SHX Text
1

DATE

REVISIONS

DESIGN ARCHITECT

PROJECT ARCHITECT

NUMBER DATE

PROJECT ENGINEER

NOV 29, 2016

SHEET TITLE

KEY PLAN

SPECTRUM DESIGN PROJECT NO. 16056

GENERAL NOTES

CHECKED BY

DRAWN BY

10 CHURCH AVE SE, PLAZA SUITE 1 ROANOKE, VIRGINIA 24011 540.342.6001

J:\16056\P

lum

b\D

wg\16056_P

501.dw

g, P

lotted B

y: trutledge, P

lotted: N

ov 28, 2016 - 2:59pm

AEP ABINGDON

ABINGDON, VA

DCV

DWR

11/29/16

TRANSMISSION FACILITYRENOVATION AND ADDITION

RWM

JDB

TDR

PLUMBINGDETAILS

P501

AutoCAD SHX Text
1"HW 110%%DF
AutoCAD SHX Text
3/4"CW
AutoCAD SHX Text
%%UDETAIL- MIXING VALVE (TV-1)
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
%%UTV-1
AutoCAD SHX Text
BALL VALVE (TYP)
AutoCAD SHX Text
CHECK VALVE (TYP)
AutoCAD SHX Text
THERMOMETER
AutoCAD SHX Text
UNION (TYP)
AutoCAD SHX Text
%%UDETAIL- WATER HEATER (DWH-1)
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
DRAIN VALVE
AutoCAD SHX Text
T&P RELIEF
AutoCAD SHX Text
VALVE
AutoCAD SHX Text
THERMOMETER (TYP)
AutoCAD SHX Text
%%UEX-1
AutoCAD SHX Text
%%UDWH-1
AutoCAD SHX Text
T&P RELIEF VALVE PIPE
AutoCAD SHX Text
FULL SIZE
AutoCAD SHX Text
VACUUM RELIEF VALVE,
AutoCAD SHX Text
WATTS 36A OR EQUAL
AutoCAD SHX Text
110%%DF
AutoCAD SHX Text
%%UTV-1
AutoCAD SHX Text
1"CW
AutoCAD SHX Text
1"HW TO FIXTURES
AutoCAD SHX Text
SET TO 140%%DF
AutoCAD SHX Text
3/4"HWR
AutoCAD SHX Text
1"CW
AutoCAD SHX Text
3/4"HW
AutoCAD SHX Text
FD
AutoCAD SHX Text
3/4"CW
AutoCAD SHX Text
3/4"HWR
AutoCAD SHX Text
HWRP-1 (REFER TO DETAIL) (REFER TO DETAIL)
AutoCAD SHX Text
6" HEAT TRAP
AutoCAD SHX Text
6" HEAT TRAP
AutoCAD SHX Text
%%UDETAIL - HOT WATER RECIRCULATING
AutoCAD SHX Text
NO SCALE
AutoCAD SHX Text
%%UPUMP (HWRP-1)
AutoCAD SHX Text
UNION (TYP)
AutoCAD SHX Text
GAUGE (0-100 PSIG)
AutoCAD SHX Text
TYP DIAL TYPE PRESSURE
AutoCAD SHX Text
BALL VALVE (TYP)
AutoCAD SHX Text
SIZE, SEE %%UDWH-1%%U DETAIL
AutoCAD SHX Text
FOR CONTINUATION AND
AutoCAD SHX Text
FLOW
AutoCAD SHX Text
THERMOMETER
AutoCAD SHX Text
%%UHWRP-1
AutoCAD SHX Text
AQUASTAT TO CONTROL HWRP-1
AutoCAD SHX Text
WITHIN 5-DEG-F DROP (ADJ)
AutoCAD SHX Text
NOTE: DUE TO EXTENDED HOURS USE OF BUILDING, HWRP-1 HWRP-1 SHALL BE AVAILABLE FOR OPERATION AT ALL TIMES.
AutoCAD SHX Text
NOTE:REFER TO DETAIL FOR REFER TO DETAIL FOR TV-1..
AutoCAD SHX Text
3/4"HW 140°FFROM HEATER
AutoCAD SHX Text
3/4"HWR FROM SHOWERS
AutoCAD SHX Text
3/4"HWR FROM LAVATORIES
AutoCAD SHX Text
3/4"HWR