johnson 24 o.c. - letherer · job:(85661) / -keene lumber co /mark and kathy johnson rf / a...
TRANSCRIPT
8/12
8/12
8/12
8/12
8/12
8/12
8/12
8/12
8/12
8/12
19'1
1"
1'3'
13'1
1"55'11"
12'3"8
6'4"
23'1
1"
24'8'
14'
6'2"
8'3"815'7"8
2'2"
BP BP BP
3 1/2 x 11 7/8" HIDDEN BEAM
BEARINGRAISED 8"
BEARINGRAISED 12"
LUS24
LUS24
85661 KEENE LUMBERERIC WAHLBERGJOHNSONROOF TRUSSES24" O.C.
F2G
GG
CDDG
HG
IX
AAX
AG
B1
3 P
LY
B1 B2
E EN ENS
F2 F1 F1NG
H2
H1
PAGE NO:
1 OF 1
JOB NO:
85661
Lot
: MA
RK
AN
D K
ATH
Y J
OH
NS
ON
RF
L
ayou
t: N
L
Des
igne
r: JA
RE
D J
OR
GE
NS
EN
Con
tract
or:
C
usto
mer
: KE
EN
E L
UM
BE
R C
O
Add
ress
:
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / A 23'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :W2, W3 2x4 SPF #3:
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.15 23.77Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Truss passed check for 20 psf additional bottom chord live load inareas with 42"-high x 24"-wide clearance.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = A 23'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 5 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 1795 / - / 339 / - / 145 / 5.5H 1796 / - / 339 / - / - / 3.5Wind reactions based on MWFRSB Min Brg Width Req = 2.8H Min Brg Width Req = 2.8Bearings B & H Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 148 - 2377C - D 174 - 2096D - E 203 - 2048
Chords Tens. Comp.
E - F 202 - 2049F - G 174 - 2098G - H 148 - 2379H - I 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - L 1833 - 21L - K 1237 0
Chords Tens. Comp.
K - J 1237 0J - H 1834 - 24
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
C - L 161 - 657L - E 923 - 56
Webs Tens. Comp.
E - J 926 - 56J - G 161 - 657
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
A 23'11" Common
WEIGHT =118.8
SEQ - 213460
TYPE COMN
15'11"11 15'11"11
11'11"8 11'11"8
23'11"1'4" 1'4"
4"7
8'4"
2
9'2"
9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
CD
E
FG
H
IJKL
812
4X6(B1)
1.5X33X5
3X5
5X5
3X5 3X5
3X51.5X3
4X6(B1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / A 23'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :W2, W3 2x4 SPF #3:
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.15 23.77Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Truss passed check for 20 psf additional bottom chord live load inareas with 42"-high x 24"-wide clearance.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = A 23'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 5 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 1795 / - / 339 / - / 145 / 5.5H 1796 / - / 339 / - / - / 3.5Wind reactions based on MWFRSB Min Brg Width Req = 2.8H Min Brg Width Req = 2.8Bearings B & H Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 148 - 2377C - D 174 - 2096D - E 203 - 2048
Chords Tens. Comp.
E - F 202 - 2049F - G 174 - 2098G - H 148 - 2379H - I 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - L 1833 - 21L - K 1237 0
Chords Tens. Comp.
K - J 1237 0J - H 1834 - 24
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
C - L 161 - 657L - E 923 - 56
Webs Tens. Comp.
E - J 926 - 56J - G 161 - 657
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
A 23'11" Common
WEIGHT =118.8
SEQ - 213460
TYPE COMN
15'11"11 15'11"11
11'11"8 11'11"8
23'11"1'4" 1'4"
4"7
8'4"
2
9'2"
9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
CD
E
FG
H
IJKL
812
4X6(B1)
1.5X33X5
3X5
5X5
3X5 3X5
3X51.5X3
4X6(B1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / AG 23'11" Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :C6 2x4 SPF #1/#2:
All plates are 1.5X3 except as noted. 90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10015050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.(a) #3 or better scab brace. Same size & 80% length of web member.
Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 0.15 23.77Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = AG 23'11" Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
B* 218 / - / 533 / - / 202 / 167V* 195 / 62 / 372 / - / - / 119Wind reactions based on MWFRSB Min Brg Width Req = -V Min Brg Width Req = -Bearings B & V are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 121 0B - C 78 - 155C - D 75 - 125D - E 71 - 122E - F 74 - 115F - G 90 - 39G - H 146 - 131H - I 214 - 160
Chords Tens. Comp.
I - J 214 - 160J - K 146 - 131K - L 90 - 51L - M 74 - 115M - N 71 - 122N - O 86 - 125O - P 90 - 155P - Q 121 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B -AB 169 - 97AB-AA 173 - 99AA- Z 175 - 101Z - Y 177 - 102Y - X 178 - 103X - W 180 - 104
Chords Tens. Comp.
W - V 180 - 104V - U 179 - 113U - T 178 - 112T - S 176 - 111S - R 173 - 109R - P 170 - 107
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
C -AB 69 - 215D -AA 92 - 337E - Z 87 - 329G - Y 89 - 408
Gables Tens. Comp.
V - J 96 - 506U - K 89 - 408T - M 87 - 329S - N 92 - 337
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
AG 23'11" Gable
WEIGHT =152.2
SEQ - 213462
TYPE GABL
23'11"
15'11"11 15'11"11
11'11"8 11'11"8
13'11"12 9'11"41'4" 1'4"
4"7
8'4"
2
9'2"
9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
QRSTUVWXYZAAAB
812
3X4(A1)
3X5
5X5
5X6
3X5
3X4(A1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / AG 23'11" Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :C6 2x4 SPF #1/#2:
All plates are 1.5X3 except as noted. 90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10015050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.(a) #3 or better scab brace. Same size & 80% length of web member.
Attach with 10d Box or Gun (0.128"x3",min.)nails @ 6" OC.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 0.15 23.77Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = AG 23'11" Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
B* 218 / - / 533 / - / 202 / 167V* 195 / 62 / 372 / - / - / 119Wind reactions based on MWFRSB Min Brg Width Req = -V Min Brg Width Req = -Bearings B & V are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 121 0B - C 78 - 155C - D 75 - 125D - E 71 - 122E - F 74 - 115F - G 90 - 39G - H 146 - 131H - I 214 - 160
Chords Tens. Comp.
I - J 214 - 160J - K 146 - 131K - L 90 - 51L - M 74 - 115M - N 71 - 122N - O 86 - 125O - P 90 - 155P - Q 121 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B -AB 169 - 97AB-AA 173 - 99AA- Z 175 - 101Z - Y 177 - 102Y - X 178 - 103X - W 180 - 104
Chords Tens. Comp.
W - V 180 - 104V - U 179 - 113U - T 178 - 112T - S 176 - 111S - R 173 - 109R - P 170 - 107
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
C -AB 69 - 215D -AA 92 - 337E - Z 87 - 329G - Y 89 - 408
Gables Tens. Comp.
V - J 96 - 506U - K 89 - 408T - M 87 - 329S - N 92 - 337
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
AG 23'11" Gable
WEIGHT =152.2
SEQ - 213462
TYPE GABL
23'11"
15'11"11 15'11"11
11'11"8 11'11"8
13'11"12 9'11"41'4" 1'4"
4"7
8'4"
2
9'2"
9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
(a)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
QRSTUVWXYZAAAB
812
3X4(A1)
3X5
5X5
5X6
3X5
3X4(A1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / AG 23'11" Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.
PLT TYP. WAVEDESC = AG 23'11" Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
H - X 96 - 506I - W 0 - 295
R - O 69 - 215
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
AG 23'11" Gable
WEIGHT =152.2
SEQ - 213462
TYPE GABL
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / AX 23'11" Common Girder This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x12 SP 2400f-2.0E Webs 2x4 SPF Stud :W3 2x4 SPF #1/#2:
Nail Schedule:0.131"x3", min. nailsTop Chord: 1 Row @10.50" o.c.Bot Chord: 2 Rows @ 4.00" o.c. (Each Row)Webs : 1 Row @ 4" o.c.Repeat nailing as each layer is applied. Use equal spacingbetween rows and stagger nails in each row to avoid splitting.4" o.c. spacing of nails perpendicular and parallel tograin required in area over bearings greater than 4"
Special loads------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15) TC- From 111 plf at -1.33 to 111 plf at 11.96 TC- From 111 plf at 11.96 to 111 plf at 25.25 BC- From 5 plf at -1.33 to 5 plf at 0.00 BC- From 20 plf at 0.00 to 20 plf at 4.00 BC- From 722 plf at 4.00 to 722 plf at 9.98 BC- From 722 plf at 9.98 to 722 plf at 17.58 BC- From 20 plf at 17.58 to 20 plf at 23.92 BC- From 5 plf at 23.92 to 5 plf at 25.25 BC- 1839.00 lb Conc. Load at 2.00 BC- 1260.00 lb Conc. Load at 4.00 BC- 2732.00 lb Conc. Load at 17.58
(**) 2 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf. Wind loads and reactions based on MWFRS with additional C&C
member design.Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
PLT TYP. WAVEDESC = AX 23'11" Common Girder
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 3 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
L 10422 / - / 2444 / - / 145 / 5.5F 8382 / - / 2066 / - / - / 3.5Wind reactions based on MWFRSL Min Brg Width Req = 3.8F Min Brg Width Req = 3.0Bearings L & F Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 29 - 1B - C 45 - 4719C - D 54 - 3328
Chords Tens. Comp.
D - E 54 - 3326E - F 45 - 4591F - G 29 - 1
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - K 3886 0K - J 3863 0J - I 3863 0
Chords Tens. Comp.
I - H 3755 0H - F 3775 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
K - C 1509 0C - I 36 - 1478D - I 3440 - 25
Webs Tens. Comp.
I - E 36 - 1338E - H 1356 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
AX 23'11" Common Girder
WEIGHT =562.9
SEQ - 213468
TYPE COMN
3 Complete Trusses Required
15'11"11 15'11"11
11'11"8 11'11"8
23'11"1'4" 1'4"
4"7
8'4"
2
9'2"
9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
GHIJK
L
812
5X8(A9R)
SS0312(**)
6X8
10X10
5X6
8X10
6X8
SS0312(**)
5X7(A9R)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / AX 23'11" Common Girder This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x12 SP 2400f-2.0E Webs 2x4 SPF Stud :W3 2x4 SPF #1/#2:
Nail Schedule:0.131"x3", min. nailsTop Chord: 1 Row @10.50" o.c.Bot Chord: 2 Rows @ 4.00" o.c. (Each Row)Webs : 1 Row @ 4" o.c.Repeat nailing as each layer is applied. Use equal spacingbetween rows and stagger nails in each row to avoid splitting.4" o.c. spacing of nails perpendicular and parallel tograin required in area over bearings greater than 4"
Special loads------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15) TC- From 111 plf at -1.33 to 111 plf at 11.96 TC- From 111 plf at 11.96 to 111 plf at 25.25 BC- From 5 plf at -1.33 to 5 plf at 0.00 BC- From 20 plf at 0.00 to 20 plf at 4.00 BC- From 722 plf at 4.00 to 722 plf at 9.98 BC- From 722 plf at 9.98 to 722 plf at 17.58 BC- From 20 plf at 17.58 to 20 plf at 23.92 BC- From 5 plf at 23.92 to 5 plf at 25.25 BC- 1839.00 lb Conc. Load at 2.00 BC- 1260.00 lb Conc. Load at 4.00 BC- 2732.00 lb Conc. Load at 17.58
(**) 2 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf. Wind loads and reactions based on MWFRS with additional C&C
member design.Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
PLT TYP. WAVEDESC = AX 23'11" Common Girder
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 3 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
L 10422 / - / 2444 / - / 145 / 5.5F 8382 / - / 2066 / - / - / 3.5Wind reactions based on MWFRSL Min Brg Width Req = 3.8F Min Brg Width Req = 3.0Bearings L & F Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 29 - 1B - C 45 - 4719C - D 54 - 3328
Chords Tens. Comp.
D - E 54 - 3326E - F 45 - 4591F - G 29 - 1
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - K 3886 0K - J 3863 0J - I 3863 0
Chords Tens. Comp.
I - H 3755 0H - F 3775 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
K - C 1509 0C - I 36 - 1478D - I 3440 - 25
Webs Tens. Comp.
I - E 36 - 1338E - H 1356 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
AX 23'11" Common Girder
WEIGHT =562.9
SEQ - 213468
TYPE COMN
3 Complete Trusses Required
15'11"11 15'11"11
11'11"8 11'11"8
23'11"1'4" 1'4"
4"7
8'4"
2
9'2"
9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
GHIJK
L
812
5X8(A9R)
SS0312(**)
6X8
10X10
5X6
8X10
6X8
SS0312(**)
5X7(A9R)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / AX 23'11" Common Girder This dwg. prepared by the ITW job designer program from truss mfr's layout.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.15 23.77Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
PLT TYP. WAVEDESC = AX 23'11" Common Girder
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 3 QTY= 1 REV. 14.03.01G.0123.00
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
AX 23'11" Common Girder
WEIGHT =562.9
SEQ - 213468
TYPE COMN
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / E 14'3"8 Scissor Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :W3, W4, W6 2x4 SPF #1/#2::Lt Bearing Leg 2x6 SPF Stud:
(**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design. Max JT VERT DEFL: LL: 0.26" DL: 0.17". See detail
DEFLCAMB0813 for camber recommendations. Roofs incorporatingthis truss require consideration for ponding design by BuildingDesigner.
(a) Continuous lateral restraint equally spaced on member.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 0.46 14.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.Unbalanced snow loads have not been considered.
Shim all supports to solid bearing.
PLT TYP. WAVEDESC = E 14'3"8 Scissor Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 5 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
K 969 / - / 206 / - / 198 / 3.5G 1112 / 34 / 277 / - / - / 3.5Wind reactions based on MWFRSK Min Brg Width Req = 1.5G Min Brg Width Req = 1.5Bearing K is a rigid surface.Bearing G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 89 - 553B - C 413 - 3029C - D 408 - 3276
Chords Tens. Comp.
D - E 393 - 3119E - F 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
K - J 3144 - 230J - I 3088 - 327
Chords Tens. Comp.
I - H 3039 - 337H - G 81 - 24
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
A - K 893 0K - A 472 - 1532K - B 394 - 2411B - J 228 0
Webs Tens. Comp.
J - D 106 - 9D - H 152 - 591H - E 2636 - 265E - G 205 - 1075
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
E 14'3"8 Scissor Mono
WEIGHT =88.0
SEQ - 213471
TYPE SCIM
18'9"6
16'3"5
14'3"8
5"813'10" 1'4"
14'3"8
9'1"
121'
8"9
1'4"
9'0"
5
10'1
0"5
17'2"14
8'1"2
LEFT RAKE = 6"10 RIGHT RAKE = 1'7"4
(a)
A
B
C
D
E
F
G
H
I
J
K 812
812
4X62X6
5X5(**)3X8
3X4
3X5
H0308
3X4
5X5
5X5
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / E 14'3"8 Scissor Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud :W3, W4, W6 2x4 SPF #1/#2::Lt Bearing Leg 2x6 SPF Stud:
(**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design. Max JT VERT DEFL: LL: 0.26" DL: 0.17". See detail
DEFLCAMB0813 for camber recommendations. Roofs incorporatingthis truss require consideration for ponding design by BuildingDesigner.
(a) Continuous lateral restraint equally spaced on member.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 0.46 14.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.Unbalanced snow loads have not been considered.
Shim all supports to solid bearing.
PLT TYP. WAVEDESC = E 14'3"8 Scissor Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 5 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
K 969 / - / 206 / - / 198 / 3.5G 1112 / 34 / 277 / - / - / 3.5Wind reactions based on MWFRSK Min Brg Width Req = 1.5G Min Brg Width Req = 1.5Bearing K is a rigid surface.Bearing G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 89 - 553B - C 413 - 3029C - D 408 - 3276
Chords Tens. Comp.
D - E 393 - 3119E - F 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
K - J 3144 - 230J - I 3088 - 327
Chords Tens. Comp.
I - H 3039 - 337H - G 81 - 24
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
A - K 893 0K - A 472 - 1532K - B 394 - 2411B - J 228 0
Webs Tens. Comp.
J - D 106 - 9D - H 152 - 591H - E 2636 - 265E - G 205 - 1075
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
E 14'3"8 Scissor Mono
WEIGHT =88.0
SEQ - 213471
TYPE SCIM
18'9"6
16'3"5
14'3"8
5"813'10" 1'4"
14'3"8
9'1"
121'
8"9
1'4"
9'0"
5
10'1
0"5
17'2"14
8'1"2
LEFT RAKE = 6"10 RIGHT RAKE = 1'7"4
(a)
A
B
C
D
E
F
G
H
I
J
K 812
812
4X62X6
5X5(**)3X8
3X4
3X5
H0308
3X4
5X5
5X5
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / EN 14'3"8 Scissor Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SP 2850f-2.3E :T2 2x4 SPF #1/#2:Bot chord 2x4 SPF #1/#2 :B1 2x8 SP 2400f-2.0E: Webs 2x4 SPF Stud :W1 2x6 SPF Stud::W6 2x4 SPF #1/#2:
(**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design. Calculated horizontal deflection is 0.19" due to live load and 0.12"
due to dead load.Max JT VERT DEFL: LL: 0.36" DL: 0.23". See detailDEFLCAMB0813 for camber recommendations. Roofs incorporatingthis truss require consideration for ponding design by BuildingDesigner.
(a) Continuous lateral restraint equally spaced on member.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 8 -0.46 -0.16 BC 75 -0.16 13.83Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50. Unbalanced snow loads have not been considered.
Handling stresses not considered for plates. Handling of this trussrequires special care by truss manufacturer and installation contractorto prevent plate damage.
PLT TYP. WAVEDESC = EN 14'3"8 Scissor Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
L 951 / - / 192 / - / 190 / 3.5G 1125 / 45 / 285 / - / - / 3.5Wind reactions based on MWFRSL Min Brg Width Req = 1.5G Min Brg Width Req = 1.5Bearing L is a rigid surface.Bearing G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 313 - 62B - C 601 - 3224C - D 596 - 3472
Chords Tens. Comp.
D - E 478 - 3152E - F 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
L - A 320 - 55K - J 3399 - 415J - I 3114 - 412
Chords Tens. Comp.
I - H 3066 - 422H - G 82 - 23
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
K - A 775 - 52K - B 377 - 3209B - J 200 0J - D 225 0
Webs Tens. Comp.
D - H 171 - 593H - E 2660 - 338E - G 225 - 1090
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
EN 14'3"8 Scissor Mono
WEIGHT =88.2
SEQ - 213474
TYPE SCIM
17'10"76"12
16'5"10
9"113'6"7
3"93"313'8"12 1'4"
14'3"8
10'1
"10
7"4
1'4"
10'4
"5
9'1"
101'
7"4
10'8
"14
18'2"12
8'1"2
RIGHT RAKE = 1'7"4
(a)
A
B
C
D
E
F
G
H
I
J
K
L
812
812
SS0708
H0510(**)
5X5
3X4
3X5
H0308
3X4
5X5
5X5
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / EN 14'3"8 Scissor Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SP 2850f-2.3E :T2 2x4 SPF #1/#2:Bot chord 2x4 SPF #1/#2 :B1 2x8 SP 2400f-2.0E: Webs 2x4 SPF Stud :W1 2x6 SPF Stud::W6 2x4 SPF #1/#2:
(**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design. Calculated horizontal deflection is 0.19" due to live load and 0.12"
due to dead load.Max JT VERT DEFL: LL: 0.36" DL: 0.23". See detailDEFLCAMB0813 for camber recommendations. Roofs incorporatingthis truss require consideration for ponding design by BuildingDesigner.
(a) Continuous lateral restraint equally spaced on member.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 8 -0.46 -0.16 BC 75 -0.16 13.83Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50. Unbalanced snow loads have not been considered.
Handling stresses not considered for plates. Handling of this trussrequires special care by truss manufacturer and installation contractorto prevent plate damage.
PLT TYP. WAVEDESC = EN 14'3"8 Scissor Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
L 951 / - / 192 / - / 190 / 3.5G 1125 / 45 / 285 / - / - / 3.5Wind reactions based on MWFRSL Min Brg Width Req = 1.5G Min Brg Width Req = 1.5Bearing L is a rigid surface.Bearing G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 313 - 62B - C 601 - 3224C - D 596 - 3472
Chords Tens. Comp.
D - E 478 - 3152E - F 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
L - A 320 - 55K - J 3399 - 415J - I 3114 - 412
Chords Tens. Comp.
I - H 3066 - 422H - G 82 - 23
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
K - A 775 - 52K - B 377 - 3209B - J 200 0J - D 225 0
Webs Tens. Comp.
D - H 171 - 593H - E 2660 - 338E - G 225 - 1090
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
EN 14'3"8 Scissor Mono
WEIGHT =88.2
SEQ - 213474
TYPE SCIM
17'10"76"12
16'5"10
9"113'6"7
3"93"313'8"12 1'4"
14'3"8
10'1
"10
7"4
1'4"
10'4
"5
9'1"
101'
7"4
10'8
"14
18'2"12
8'1"2
RIGHT RAKE = 1'7"4
(a)
A
B
C
D
E
F
G
H
I
J
K
L
812
812
SS0708
H0510(**)
5X5
3X4
3X5
H0308
3X4
5X5
5X5
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / ENS 13'3"8 Scissor Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SP 2850f-2.3EBot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Lt Bearing Leg 2x6 SPF Stud:
(**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design. Max JT VERT DEFL: LL: 0.20" DL: 0.13". See detail
DEFLCAMB0813 for camber recommendations. Roofs incorporatingthis truss require consideration for ponding design by BuildingDesigner.
(a) Continuous lateral restraint equally spaced on member.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.10 12.73Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.Unbalanced snow loads have not been considered.
Shim all supports to solid bearing.
PLT TYP. WAVEDESC = ENS 13'3"8 Scissor Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 4 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
A 906 / - / 190 / - / 169 / 3.5F 886 / 23 / 235 / - / - / 3.5Wind reactions based on MWFRSA Min Brg Width Req = 1.5F Min Brg Width Req = 1.5Bearings A & F are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 278 - 175B - C 561 - 2908
Chords Tens. Comp.
C - D 540 - 2956D - E 427 - 2757
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
I - H 2855 - 425H - G 2730 - 407
Chords Tens. Comp.
G - F 77 - 23
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
I - A 718 - 71I - B 364 - 2530B - H 195 0H - D 114 - 3
Webs Tens. Comp.
D - G 166 - 551G - E 2309 - 325E - F 148 - 854
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
ENS 13'3"8 Scissor Mono
WEIGHT =79.3
SEQ - 213211
TYPE SCIM
15'11"11
15'0"14
13'3"8
5"812'10"
13'3"8
9'5"
10
8"11
1'4"
8'4"
5
10'2
"5
18'2"12
8'9"2
LEFT RAKE = 6"10
(a)
A
B
C
D
E
F
G
H
I
812
812
3X5(**)
5X5
2X4
3X8
3X43X5
3X4
5X7
5X6
2X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / ENS 13'3"8 Scissor Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SP 2850f-2.3EBot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Lt Bearing Leg 2x6 SPF Stud:
(**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design. Max JT VERT DEFL: LL: 0.20" DL: 0.13". See detail
DEFLCAMB0813 for camber recommendations. Roofs incorporatingthis truss require consideration for ponding design by BuildingDesigner.
(a) Continuous lateral restraint equally spaced on member.In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 75 -0.10 12.73Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.Unbalanced snow loads have not been considered.
Shim all supports to solid bearing.
PLT TYP. WAVEDESC = ENS 13'3"8 Scissor Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 4 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
A 906 / - / 190 / - / 169 / 3.5F 886 / 23 / 235 / - / - / 3.5Wind reactions based on MWFRSA Min Brg Width Req = 1.5F Min Brg Width Req = 1.5Bearings A & F are a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 278 - 175B - C 561 - 2908
Chords Tens. Comp.
C - D 540 - 2956D - E 427 - 2757
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
I - H 2855 - 425H - G 2730 - 407
Chords Tens. Comp.
G - F 77 - 23
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
I - A 718 - 71I - B 364 - 2530B - H 195 0H - D 114 - 3
Webs Tens. Comp.
D - G 166 - 551G - E 2309 - 325E - F 148 - 854
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
ENS 13'3"8 Scissor Mono
WEIGHT =79.3
SEQ - 213211
TYPE SCIM
15'11"11
15'0"14
13'3"8
5"812'10"
13'3"8
9'5"
10
8"11
1'4"
8'4"
5
10'2
"5
18'2"12
8'9"2
LEFT RAKE = 6"10
(a)
A
B
C
D
E
F
G
H
I
812
812
3X5(**)
5X5
2X4
3X8
3X43X5
3X4
5X7
5X6
2X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F1N 13'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2 :T2 2x4 SP 2850f-2.3E:Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Rt Bearing Leg 2x6 SPF Stud:
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 -0.46 13.00Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.Bottom chord checked for 10.00 psf non-concurrent bottom chord live
load applied per IBC-09 section 1607.Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = F1N 13'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 7 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
I 1062 / 23 / 206 / - / 91 / 3.5F 903 / 16 / 162 / - / - / 3.5Wind reactions based on MWFRSI Min Brg Width Req = 1.7F Min Brg Width Req = 1.5Bearing F is a rigid surface.Bearing I Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 87 - 117C - D 99 - 784
Chords Tens. Comp.
D - E 98 - 797E - F 201 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
I - H 652 - 44
Chords Tens. Comp.
H - G 662 - 43
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - I 123 - 344I - C 33 - 918C - H 94 - 181D - H 330 - 22
Webs Tens. Comp.
H - E 90 - 211E - G 75 - 1084F - G 897 - 29
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F1N 13'11" Common
WEIGHT =91.1
SEQ - 213476
TYPE COMN
9'11"98'4"6
6'11"8 6'11"8
13'5"85"8
1'4"
13'11"
11"141'6"
4
6"6
6'1"
15
17'2"14
18'2"12
LEFT RAKE = 1'7"4 RIGHT RAKE = 6"10
A
B
C
D
E
F
GHI
812
1.5X3
3X4
3X4
4X4
3X8
3X4
4X4
3X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F1N 13'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2 :T2 2x4 SP 2850f-2.3E:Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Rt Bearing Leg 2x6 SPF Stud:
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 -0.46 13.00Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.Bottom chord checked for 10.00 psf non-concurrent bottom chord live
load applied per IBC-09 section 1607.Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = F1N 13'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 7 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
I 1062 / 23 / 206 / - / 91 / 3.5F 903 / 16 / 162 / - / - / 3.5Wind reactions based on MWFRSI Min Brg Width Req = 1.7F Min Brg Width Req = 1.5Bearing F is a rigid surface.Bearing I Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 87 - 117C - D 99 - 784
Chords Tens. Comp.
D - E 98 - 797E - F 201 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
I - H 652 - 44
Chords Tens. Comp.
H - G 662 - 43
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - I 123 - 344I - C 33 - 918C - H 94 - 181D - H 330 - 22
Webs Tens. Comp.
H - E 90 - 211E - G 75 - 1084F - G 897 - 29
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F1N 13'11" Common
WEIGHT =91.1
SEQ - 213476
TYPE COMN
9'11"98'4"6
6'11"8 6'11"8
13'5"85"8
1'4"
13'11"
11"141'6"
4
6"6
6'1"
15
17'2"14
18'2"12
LEFT RAKE = 1'7"4 RIGHT RAKE = 6"10
A
B
C
D
E
F
GHI
812
1.5X3
3X4
3X4
4X4
3X8
3X4
4X4
3X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F1 13'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 13.92Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = F1 13'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 5 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
I 1072 / 23 / 208 / - / 91 / 3.5G 903 / 11 / 166 / - / - / 3.5Wind reactions based on MWFRSI Min Brg Width Req = 1.7G Min Brg Width Req = 1.5Bearings I & G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 88 - 117C - D 99 - 799
Chords Tens. Comp.
D - E 100 - 802E - F 97 - 109
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
I - H 662 - 44
Chords Tens. Comp.
H - G 684 - 44
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - I 123 - 343I - C 33 - 933C - H 95 - 182D - H 349 - 27
Webs Tens. Comp.
H - E 96 - 223E - G 69 - 952F - G 37 - 161
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F1 13'11" Common
WEIGHT =89.9
SEQ - 213478
TYPE COMN
9'11"98'4"6
6'11"8 6'11"8
13'11"1'4"
1'6"
4
6'1"
15
17'2"14
LEFT RAKE = 1'7"4
A
B
C
D
E
F
GHI
812
1.5X3
3X4
3X4
4X4
3X8
3X4
1.5X3
3X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F1 13'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 13.92Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = F1 13'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 5 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
I 1072 / 23 / 208 / - / 91 / 3.5G 903 / 11 / 166 / - / - / 3.5Wind reactions based on MWFRSI Min Brg Width Req = 1.7G Min Brg Width Req = 1.5Bearings I & G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 88 - 117C - D 99 - 799
Chords Tens. Comp.
D - E 100 - 802E - F 97 - 109
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
I - H 662 - 44
Chords Tens. Comp.
H - G 684 - 44
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - I 123 - 343I - C 33 - 933C - H 95 - 182D - H 349 - 27
Webs Tens. Comp.
H - E 96 - 223E - G 69 - 952F - G 37 - 161
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F1 13'11" Common
WEIGHT =89.9
SEQ - 213478
TYPE COMN
9'11"98'4"6
6'11"8 6'11"8
13'11"1'4"
1'6"
4
6'1"
15
17'2"14
LEFT RAKE = 1'7"4
A
B
C
D
E
F
GHI
812
1.5X3
3X4
3X4
4X4
3X8
3X4
1.5X3
3X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F2 13'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 13.92Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = F2 13'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
J 1065 / 23 / 207 / - / 101 / 3.5H 1065 / 23 / 207 / - / - / 3.5Wind reactions based on MWFRSJ Min Brg Width Req = 1.7H Min Brg Width Req = 1.7Bearings J & H Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 89 - 117C - D 100 - 789
Chords Tens. Comp.
D - E 100 - 789E - F 89 - 117F - G 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
J - I 655 - 20
Chords Tens. Comp.
I - H 655 - 18
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - J 123 - 343J - C 34 - 923C - I 95 - 195D - I 331 - 25
Webs Tens. Comp.
I - E 95 - 195E - H 34 - 923F - H 122 - 343
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F2 13'11" Common
WEIGHT =92.7
SEQ - 213480
TYPE COMN
9'11"9 9'11"9
6'11"8 6'11"8
13'11"1'4" 1'4"
1'6"
4
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
G
HIJ
812
1.5X3
3X4
3X4
4X4
3X8
3X4
1.5X3
3X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F2 13'11" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 13.92Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = F2 13'11" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
J 1065 / 23 / 207 / - / 101 / 3.5H 1065 / 23 / 207 / - / - / 3.5Wind reactions based on MWFRSJ Min Brg Width Req = 1.7H Min Brg Width Req = 1.7Bearings J & H Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 89 - 117C - D 100 - 789
Chords Tens. Comp.
D - E 100 - 789E - F 89 - 117F - G 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
J - I 655 - 20
Chords Tens. Comp.
I - H 655 - 18
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - J 123 - 343J - C 34 - 923C - I 95 - 195D - I 331 - 25
Webs Tens. Comp.
I - E 95 - 195E - H 34 - 923F - H 122 - 343
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F2 13'11" Common
WEIGHT =92.7
SEQ - 213480
TYPE COMN
9'11"9 9'11"9
6'11"8 6'11"8
13'11"1'4" 1'4"
1'6"
4
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
G
HIJ
812
1.5X3
3X4
3X4
4X4
3X8
3X4
1.5X3
3X4
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F2G 13'11" Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
All plates are 1.5X3 except as noted. 90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10030050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 13.92Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.Deflection meets L/360 live and L/240 total load. Creep increase
factor for dead load is 1.50.Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.Fasten rated sheathing to one face of this frame.
PLT TYP. WAVEDESC = F2G 13'11" Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
T* 217 / 177 / 428 / - / 141 / 167Wind reactions based on MWFRST Min Brg Width Req = -Bearing T is a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 126 0B - C 100 - 137C - D 129 - 104D - E 191 - 101E - F 261 - 138
Chords Tens. Comp.
F - G 261 - 138G - H 191 - 101H - I 128 - 104I - J 100 - 137J - K 126 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
T - S 66 - 62S - R 73 - 67R - Q 73 - 68Q - P 73 - 69
Chords Tens. Comp.
P - O 73 - 69O - N 74 - 69N - M 74 - 68M - L 78 - 74
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
T - B 159 - 446C - S 142 - 119D - R 97 - 335E - Q 101 - 457F - P 0 - 288
Gables Tens. Comp.
O - G 101 - 457N - H 98 - 335M - I 144 - 121J - L 156 - 446
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F2G 13'11" Gable
WEIGHT =93.1
SEQ - 213482
TYPE GABL
13'11"
9'11"9 9'11"9
6'11"8 6'11"8
13'11"1'4" 1'4"
1'6"
4
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
G
H
I
J
K
LMNOPQRS
T
812
2X6
4X4
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / F2G 13'11" Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
All plates are 1.5X3 except as noted. 90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10030050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 13.92Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.Deflection meets L/360 live and L/240 total load. Creep increase
factor for dead load is 1.50.Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.Fasten rated sheathing to one face of this frame.
PLT TYP. WAVEDESC = F2G 13'11" Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
T* 217 / 177 / 428 / - / 141 / 167Wind reactions based on MWFRST Min Brg Width Req = -Bearing T is a rigid surface.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 126 0B - C 100 - 137C - D 129 - 104D - E 191 - 101E - F 261 - 138
Chords Tens. Comp.
F - G 261 - 138G - H 191 - 101H - I 128 - 104I - J 100 - 137J - K 126 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
T - S 66 - 62S - R 73 - 67R - Q 73 - 68Q - P 73 - 69
Chords Tens. Comp.
P - O 73 - 69O - N 74 - 69N - M 74 - 68M - L 78 - 74
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
T - B 159 - 446C - S 142 - 119D - R 97 - 335E - Q 101 - 457F - P 0 - 288
Gables Tens. Comp.
O - G 101 - 457N - H 98 - 335M - I 144 - 121J - L 156 - 446
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
F2G 13'11" Gable
WEIGHT =93.1
SEQ - 213482
TYPE GABL
13'11"
9'11"9 9'11"9
6'11"8 6'11"8
13'11"1'4" 1'4"
1'6"
4
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
G
H
I
J
K
LMNOPQRS
T
812
2X6
4X4
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / H2 12'3"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.36 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.09 12.20Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = H2 12'3"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 958 / 20 / 196 / - / 92 / 3.5D 958 / 20 / 196 / - / - / 3.5Wind reactions based on MWFRSB Min Brg Width Req = 1.5D Min Brg Width Req = 1.5Bearings B & D Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 73 - 929
Chords Tens. Comp.
C - D 74 - 929D - E 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - F 624 0
Chords Tens. Comp.
F - D 624 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
C - F 271 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
H2 12'3"8 Common
WEIGHT =53.2
SEQ - 213484
TYPE COMN
8'11"14 8'11"14
6'1"12 6'1"12
12'3"81'4" 1'4"
6"4
4'7"
7
5'4"
1
18'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
EF
812
3X4(B1)
4X6(R1)
1.5X4
3X4(B1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / H2 12'3"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.36 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.09 12.20Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = H2 12'3"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 958 / 20 / 196 / - / 92 / 3.5D 958 / 20 / 196 / - / - / 3.5Wind reactions based on MWFRSB Min Brg Width Req = 1.5D Min Brg Width Req = 1.5Bearings B & D Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 73 - 929
Chords Tens. Comp.
C - D 74 - 929D - E 86 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - F 624 0
Chords Tens. Comp.
F - D 624 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
C - F 271 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
H2 12'3"8 Common
WEIGHT =53.2
SEQ - 213484
TYPE COMN
8'11"14 8'11"14
6'1"12 6'1"12
12'3"81'4" 1'4"
6"4
4'7"
7
5'4"
1
18'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
EF
812
3X4(B1)
4X6(R1)
1.5X4
3X4(B1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / H1 12'3"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.81 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.09 12.20Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = H1 12'3"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 4 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
A 804 / 9 / 152 / - / 65 / 3.5C 804 / 9 / 152 / - / - / 3.5Wind reactions based on MWFRSA Min Brg Width Req = 1.5C Min Brg Width Req = 1.5Bearings A & C Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 83 - 967
Chords Tens. Comp.
B - C 83 - 967
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - D 663 0
Chords Tens. Comp.
D - C 663 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - D 274 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 04/28/15
H1 12'3"8 Common
WEIGHT =47.6
SEQ - 106892
TYPE COMN
7'4"10 7'4"10
6'1"12 6'1"12
12'3"8
6"4
4'7"
7
18'2"14
A
B
C
D
812
3X4(B1)
4X6(R1)
1.5X4
3X4(B1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / H1 12'3"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.81 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.09 12.20Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = H1 12'3"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 4 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
A 804 / 9 / 152 / - / 65 / 3.5C 804 / 9 / 152 / - / - / 3.5Wind reactions based on MWFRSA Min Brg Width Req = 1.5C Min Brg Width Req = 1.5Bearings A & C Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 83 - 967
Chords Tens. Comp.
B - C 83 - 967
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - D 663 0
Chords Tens. Comp.
D - C 663 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - D 274 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 04/28/15
H1 12'3"8 Common
WEIGHT =47.6
SEQ - 106892
TYPE COMN
7'4"10 7'4"10
6'1"12 6'1"12
12'3"8
6"4
4'7"
7
18'2"14
A
B
C
D
812
3X4(B1)
4X6(R1)
1.5X4
3X4(B1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / IX 12'3"8 Common Girder This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x6 SP 2700f-2.0E Webs 2x4 SPF Stud
Special loads------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15) TC- From 55 plf at 0.00 to 55 plf at 6.15 TC- From 55 plf at 6.15 to 55 plf at 12.29 BC- From 10 plf at 0.00 to 10 plf at 12.29 BC- 480.21 lb Conc. Load at 0.48, 2.48, 4.48, 6.48 8.48,10.48 BC- 684.66 lb Conc. Load at 12.23
90 mph wind, 20.81 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS. In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 12.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = IX 12'3"8 Common Girder
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
F 2002 / 270 / - / - / - / 3.5D 2368 / 545 / - / - / - / 3.5Wind reactions based on MWFRSF Min Brg Width Req = 1.9D Min Brg Width Req = 2.2Bearings F & D Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 227 - 1695
Chords Tens. Comp.
B - C 227 - 1695
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
F - E 59 - 8
Chords Tens. Comp.
E - D 59 - 8
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
A - F 171 - 1272A - E 1307 - 175B - E 1396 - 184
Webs Tens. Comp.
E - C 1307 - 175C - D 171 - 1272
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 04/28/15
IX 12'3"8 Common Girder
WEIGHT =77.7
SEQ - 213175
TYPE COMN
7'4"10 7'4"10
6'1"12 6'1"12
12'3"8
1'6"
4
5'7"
7
17'2"14
A
B
C
DEF
812
3X6
2X6
5X5(R1)
6X8
3X6
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / IX 12'3"8 Common Girder This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x6 SP 2700f-2.0E Webs 2x4 SPF Stud
Special loads------(Lumber Dur.Fac.=1.15 / Plate Dur.Fac.=1.15) TC- From 55 plf at 0.00 to 55 plf at 6.15 TC- From 55 plf at 6.15 to 55 plf at 12.29 BC- From 10 plf at 0.00 to 10 plf at 12.29 BC- 480.21 lb Conc. Load at 0.48, 2.48, 4.48, 6.48 8.48,10.48 BC- 684.66 lb Conc. Load at 12.23
90 mph wind, 20.81 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS. In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 120 0.00 12.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = IX 12'3"8 Common Girder
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
F 2002 / 270 / - / - / - / 3.5D 2368 / 545 / - / - / - / 3.5Wind reactions based on MWFRSF Min Brg Width Req = 1.9D Min Brg Width Req = 2.2Bearings F & D Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 227 - 1695
Chords Tens. Comp.
B - C 227 - 1695
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
F - E 59 - 8
Chords Tens. Comp.
E - D 59 - 8
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
A - F 171 - 1272A - E 1307 - 175B - E 1396 - 184
Webs Tens. Comp.
E - C 1307 - 175C - D 171 - 1272
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 04/28/15
IX 12'3"8 Common Girder
WEIGHT =77.7
SEQ - 213175
TYPE COMN
7'4"10 7'4"10
6'1"12 6'1"12
12'3"8
1'6"
4
5'7"
7
17'2"14
A
B
C
DEF
812
3X6
2X6
5X5(R1)
6X8
3X6
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / HG 6'10"8 Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
All plates are 1.5X3 except as noted. 90 mph wind, 21.26 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.End verticals not exposed to wind pressure. Truss spaced at 24.0" OC designed to support 1-4-0 top chord
outlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10030050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 82 0.00 6.88Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
Fasten rated sheathing to one face of this frame.
PLT TYP. WAVEDESC = HG 6'10"8 Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
L* 248 / 394 / 239 / - / 89 / 82.5Wind reactions based on MWFRSL Min Brg Width Req = -Bearing L Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 121 0B - C 118 - 97C - D 185 - 111
Chords Tens. Comp.
D - E 185 - 110E - F 115 - 98F - G 121 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
L - K 41 - 43K - J 44 - 45
Chords Tens. Comp.
J - I 44 - 45I - H 45 - 47
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - L 196 - 393D - J 0 - 314
Webs Tens. Comp.
F - H 193 - 395
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
C - K 97 - 254
Gables Tens. Comp.
I - E 101 - 259
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
HG 6'10"8 Gable
WEIGHT =45.8
SEQ - 213486
TYPE GABL
6'10"8
5'8"8 5'9"2
3'5" 3'5"8
6'10"81'4" 1'4"
2'4"
1
2'3"
12
4'7"
7
18'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
G
HIJK
L
812
1.5X4
2X6
4X4
1.5X4
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / HG 6'10"8 Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
All plates are 1.5X3 except as noted. 90 mph wind, 21.26 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.End verticals not exposed to wind pressure. Truss spaced at 24.0" OC designed to support 1-4-0 top chord
outlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10030050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.In lieu of structural panels or rigid ceiling use purlins
to laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 82 0.00 6.88Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
Fasten rated sheathing to one face of this frame.
PLT TYP. WAVEDESC = HG 6'10"8 Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
L* 248 / 394 / 239 / - / 89 / 82.5Wind reactions based on MWFRSL Min Brg Width Req = -Bearing L Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 121 0B - C 118 - 97C - D 185 - 111
Chords Tens. Comp.
D - E 185 - 110E - F 115 - 98F - G 121 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
L - K 41 - 43K - J 44 - 45
Chords Tens. Comp.
J - I 44 - 45I - H 45 - 47
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - L 196 - 393D - J 0 - 314
Webs Tens. Comp.
F - H 193 - 395
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
C - K 97 - 254
Gables Tens. Comp.
I - E 101 - 259
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
HG 6'10"8 Gable
WEIGHT =45.8
SEQ - 213486
TYPE GABL
6'10"8
5'8"8 5'9"2
3'5" 3'5"8
6'10"81'4" 1'4"
2'4"
1
2'3"
12
4'7"
7
18'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
G
HIJK
L
812
1.5X4
2X6
4X4
1.5X4
2X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / D 8'3"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Lt Stub Wedge 2x4 SPF Stud::Rt Stub Wedge 2x4 SPF Stud:
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 99 0.00 8.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.Bottom chord checked for 10.00 psf non-concurrent bottom chord live
load applied per IBC-09 section 1607.Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = D 8'3"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
A 542 / - / 102 / - / 41 / 3.5C 542 / - / 102 / - / - / 3.5Wind reactions based on MWFRSA Min Brg Width Req = 1.5C Min Brg Width Req = 1.5Bearings A & C Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 65 - 646
Chords Tens. Comp.
B - C 65 - 646
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - D 430 - 5
Chords Tens. Comp.
D - C 430 - 5
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - D 178 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
D 8'3"8 Common
WEIGHT =37.6
SEQ - 213217
TYPE COMN
4'11"13 4'11"13
4'1"12 4'1"12
8'3"8
8"
3'5"
3
8'9"2
A
B
C
D
812
2X8(G1)
4X4
1.5X3
2X8(G1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / D 8'3"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Lt Stub Wedge 2x4 SPF Stud::Rt Stub Wedge 2x4 SPF Stud:
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 99 0.00 8.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.Bottom chord checked for 10.00 psf non-concurrent bottom chord live
load applied per IBC-09 section 1607.Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = D 8'3"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
A 542 / - / 102 / - / 41 / 3.5C 542 / - / 102 / - / - / 3.5Wind reactions based on MWFRSA Min Brg Width Req = 1.5C Min Brg Width Req = 1.5Bearings A & C Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 65 - 646
Chords Tens. Comp.
B - C 65 - 646
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - D 430 - 5
Chords Tens. Comp.
D - C 430 - 5
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - D 178 0
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
D 8'3"8 Common
WEIGHT =37.6
SEQ - 213217
TYPE COMN
4'11"13 4'11"13
4'1"12 4'1"12
8'3"8
8"
3'5"
3
8'9"2
A
B
C
D
812
2X8(G1)
4X4
1.5X3
2X8(G1)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / DG 8'3"8 Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Lt Stub Wedge 2x4 SPF Stud::Rt Stub Wedge 2x4 SPF Stud:
All plates are 1.5X3 except as noted. 90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10015050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 99 0.00 8.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = DG 8'3"8 Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 973 / 174 / 180 / - / 93 / 3.5F 973 / 174 / 180 / - / - / 3.5Wind reactions based on MWFRSB Min Brg Width Req = 1.5F Min Brg Width Req = 1.5Bearings B & F Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 109 0B - C 88 - 801C - D 147 - 692
Chords Tens. Comp.
D - E 147 - 692E - F 88 - 801F - G 109 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - J 540 0J - I 526 0
Chords Tens. Comp.
I - H 526 0H - F 540 0
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
C - J 81 - 185D - I 234 - 46
Gables Tens. Comp.
H - E 81 - 185
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
DG 8'3"8 Gable
WEIGHT =46.0
SEQ - 213488
TYPE GABL
6'7" 6'7"
4'1"12 4'1"12
8'3"81'4" 1'4"
8"
3'5"
3
4'0"
1
8'9"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
GHIJ
812
3X8(G7)
4X4
1.5X4
3X8(G7)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / DG 8'3"8 Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Lt Stub Wedge 2x4 SPF Stud::Rt Stub Wedge 2x4 SPF Stud:
All plates are 1.5X3 except as noted. 90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10015050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 99 0.00 8.29Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Truss designed for unbalanced snow load based on Pg=60.00 psf,Ct=1.10, Ce=1.00, CAT II & Pf=46.20 psf.
PLT TYP. WAVEDESC = DG 8'3"8 Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 973 / 174 / 180 / - / 93 / 3.5F 973 / 174 / 180 / - / - / 3.5Wind reactions based on MWFRSB Min Brg Width Req = 1.5F Min Brg Width Req = 1.5Bearings B & F Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 109 0B - C 88 - 801C - D 147 - 692
Chords Tens. Comp.
D - E 147 - 692E - F 88 - 801F - G 109 0
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - J 540 0J - I 526 0
Chords Tens. Comp.
I - H 526 0H - F 540 0
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
C - J 81 - 185D - I 234 - 46
Gables Tens. Comp.
H - E 81 - 185
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
DG 8'3"8 Gable
WEIGHT =46.0
SEQ - 213488
TYPE GABL
6'7" 6'7"
4'1"12 4'1"12
8'3"81'4" 1'4"
8"
3'5"
3
4'0"
1
8'9"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'7"4
A
B
C
D
E
F
GHIJ
812
3X8(G7)
4X4
1.5X4
3X8(G7)
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / G 6'4" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
Right end vertical not exposed to wind pressure.
(J) Hanger Support Required, by others
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 76 0.00 6.33Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = G 6'4" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 6 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
G 581 / - / 116 / - / 127 / 3.5F 474 / 77 / 130 / - / - / -Wind reactions based on MWFRSG Min Brg Width Req = 1.5F Min Brg Width Req = -Bearing G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 85 - 102
Chords Tens. Comp.
C - D 91 - 119D - E 0 - 40
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
G - F 192 - 103
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - G 129 - 321G - C 21 - 265
Webs Tens. Comp.
C - F 140 - 261D - F 93 - 236
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
G 6'4" Common
WEIGHT =49.1
SEQ - 213490
TYPE COMN
9'11"9
6'4"1'4"7"8
1'6"
4
5'8"
15
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 9"
A
B
C
D
E
FG
812
1.5X3
3X4
3X4
1.5X3
3X5
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / G 6'4" Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
Right end vertical not exposed to wind pressure.
(J) Hanger Support Required, by others
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 76 0.00 6.33Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = G 6'4" Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 6 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
G 581 / - / 116 / - / 127 / 3.5F 474 / 77 / 130 / - / - / -Wind reactions based on MWFRSG Min Brg Width Req = 1.5F Min Brg Width Req = -Bearing G Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 85 - 102
Chords Tens. Comp.
C - D 91 - 119D - E 0 - 40
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
G - F 192 - 103
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - G 129 - 321G - C 21 - 265
Webs Tens. Comp.
C - F 140 - 261D - F 93 - 236
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
G 6'4" Common
WEIGHT =49.1
SEQ - 213490
TYPE COMN
9'11"9
6'4"1'4"7"8
1'6"
4
5'8"
15
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 9"
A
B
C
D
E
FG
812
1.5X3
3X4
3X4
1.5X3
3X5
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / GG 6'4" Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
All plates are 1.5X3 except as noted. 90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10030050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.
(J) Hanger Support Required, by others In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 76 0.00 6.33Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607. Deflection meets L/360 live and L/240 total load. Creep increase
factor for dead load is 1.50.Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = GG 6'4" Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
J 818 / 35 / 146 / - / 351 / 3.5G 676 / 327 / 166 / - / - / -Wind reactions based on MWFRSJ Min Brg Width Req = 1.5G Min Brg Width Req = -Bearing J Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 121 0B - C 149 - 138C - D 19 - 154
Chords Tens. Comp.
D - E 121 - 101E - F 0 - 57
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
J - I 290 - 179I - H 297 - 179
Chords Tens. Comp.
H - G 297 - 179
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - J 235 - 462J - K 0 - 442K - C 12 - 391
Webs Tens. Comp.
C - L 229 - 360M - G 250 - 429E - G 152 - 320
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
K - I 77 0L - D 82 - 113
Gables Tens. Comp.
H - M 87 - 16
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
GG 6'4" Gable
WEIGHT =59.9
SEQ - 213492
TYPE GABL
9'11"9
6'4"1'4"7"8
1'6"
4
5'8"
15
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 9"
A
B
C
D
E
F
GHIJ
K LM
812
2X4
3X4
3X4
1.5X4
3X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / GG 6'4" Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
All plates are 1.5X3 except as noted. 90 mph wind, 20.64 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.Wind loads and reactions based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10030050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.
(J) Hanger Support Required, by others In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 76 0.00 6.33Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607. Deflection meets L/360 live and L/240 total load. Creep increase
factor for dead load is 1.50.Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = GG 6'4" Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
J 818 / 35 / 146 / - / 351 / 3.5G 676 / 327 / 166 / - / - / -Wind reactions based on MWFRSJ Min Brg Width Req = 1.5G Min Brg Width Req = -Bearing J Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 121 0B - C 149 - 138C - D 19 - 154
Chords Tens. Comp.
D - E 121 - 101E - F 0 - 57
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
J - I 290 - 179I - H 297 - 179
Chords Tens. Comp.
H - G 297 - 179
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
B - J 235 - 462J - K 0 - 442K - C 12 - 391
Webs Tens. Comp.
C - L 229 - 360M - G 250 - 429E - G 152 - 320
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
K - I 77 0L - D 82 - 113
Gables Tens. Comp.
H - M 87 - 16
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
GG 6'4" Gable
WEIGHT =59.9
SEQ - 213492
TYPE GABL
9'11"9
6'4"1'4"7"8
1'6"
4
5'8"
15
6'1"
15
17'2"14
LEFT RAKE = 1'7"4 RIGHT RAKE = 9"
A
B
C
D
E
F
GHIJ
K LM
812
2X4
3X4
3X4
1.5X4
3X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / C 6' Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Rt Bearing Leg 2x4 SPF Stud:
All plates are 1.5X3 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
End verticals not exposed to wind pressure.
Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10015050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 68 0.00 5.71Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered. Fasten rated sheathing to one face of this frame.
PLT TYP. WAVEDESC = C 6' Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
J* 186 / 2066 / 521 / - / 300 / 68.5F 210 / 279 / 1769 / - / - / 3.5Wind reactions based on MWFRSJ Min Brg Width Req = -F Min Brg Width Req = 3.5Bearings J & F Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 0 - 112B - C 91 - 126
Chords Tens. Comp.
C - D 68 - 167D - E 54 - 305
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
J - I 15 - 12I - H 19 - 29
Chords Tens. Comp.
H - G 25 - 81
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
F - G 1543 - 260E - F 622 - 111
Webs Tens. Comp.
E - F 224 - 1443
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
J - B 216 - 389I - C 72 - 277
Gables Tens. Comp.
H - D 305 - 309
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
C 6' Gable
WEIGHT =46.1
SEQ - 213273
TYPE GABL
6'
8'4"15
6'
5'8"83"8
1'
8"
6'
1'4"
6'8"
8'1"2
8'9"2
LEFT RAKE = 1'2"7 RIGHT RAKE = 4"3
A
B
C
D
E
F
GHI
J
812
2X6
4X4
2X4(**)
4X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / C 6' Gable This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud:Rt Bearing Leg 2x4 SPF Stud:
All plates are 1.5X3 except as noted. (**) 1 plate(s) require special positioning. Refer to scaled plate plotdetails for special positioning requirements.
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
End verticals not exposed to wind pressure.
Truss spaced at 24.0" OC designed to support 1-4-0 top chordoutlookers. Cladding load shall not exceed 2.00 PSF. Top chord mustnot be cut or notched.
See DWGS A10015050109, GBLLETIN0212, & GABRST050109 forgable wind bracing requirements.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 68 0.00 5.71Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered. Fasten rated sheathing to one face of this frame.
PLT TYP. WAVEDESC = C 6' Gable
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 1 REV. 14.03.01G.0123.00
Maximum Reactions (lbs), or *=PLFLoc R / U / Rw / Rh / RL / W
J* 186 / 2066 / 521 / - / 300 / 68.5F 210 / 279 / 1769 / - / - / 3.5Wind reactions based on MWFRSJ Min Brg Width Req = -F Min Brg Width Req = 3.5Bearings J & F Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 0 - 112B - C 91 - 126
Chords Tens. Comp.
C - D 68 - 167D - E 54 - 305
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
J - I 15 - 12I - H 19 - 29
Chords Tens. Comp.
H - G 25 - 81
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
F - G 1543 - 260E - F 622 - 111
Webs Tens. Comp.
E - F 224 - 1443
Maximum Gable Forces Per Ply (lbs)Gables Tens.Comp.
J - B 216 - 389I - C 72 - 277
Gables Tens. Comp.
H - D 305 - 309
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
C 6' Gable
WEIGHT =46.1
SEQ - 213273
TYPE GABL
6'
8'4"15
6'
5'8"83"8
1'
8"
6'
1'4"
6'8"
8'1"2
8'9"2
LEFT RAKE = 1'2"7 RIGHT RAKE = 4"3
A
B
C
D
E
F
GHI
J
812
2X6
4X4
2X4(**)
4X6
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / B1 3'11"8 Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
Right end vertical not exposed to wind pressure.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 34 0.15 2.96Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = B1 3'11"8 Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 382 / - / 84 / - / 63 / 5.5E 275 / 27 / 62 / - / - / -Wind reactions based on MWFRSB Min Brg Width Req = 1.5E Min Brg Width Req = -Bearing B Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 77 - 85
Chords Tens. Comp.
C - D 0 - 64
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - E 2 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
E - C 114 - 253
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
B1 3'11"8 Mono
WEIGHT =16.8
SEQ - 213494
TYPE MONO
2'11"8
6'4"5
2'11"91'4"11"15
4"7
2'4"
33'0"
2
3'10
"9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'2"5
A
B
C
D
E
812
3X4(A1)
1.5X4
1.5X3
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / B1 3'11"8 Mono This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
Right end vertical not exposed to wind pressure.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 34 0.15 2.96Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = B1 3'11"8 Mono
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 382 / - / 84 / - / 63 / 5.5E 275 / 27 / 62 / - / - / -Wind reactions based on MWFRSB Min Brg Width Req = 1.5E Min Brg Width Req = -Bearing B Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0B - C 77 - 85
Chords Tens. Comp.
C - D 0 - 64
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - E 2 0
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
E - C 114 - 253
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
B1 3'11"8 Mono
WEIGHT =16.8
SEQ - 213494
TYPE MONO
2'11"8
6'4"5
2'11"91'4"11"15
4"7
2'4"
33'0"
2
3'10
"9
8'1"2
LEFT RAKE = 1'7"4 RIGHT RAKE = 1'2"5
A
B
C
D
E
812
3X4(A1)
1.5X4
1.5X3
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / B2 2'11"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
Right end vertical not exposed to wind pressure.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 34 0.15 2.96Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = B2 2'11"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 402 / - / 92 / - / 51 / 5.5D 139 / 6 / 36 / - / - / -Wind reactions based on MWFRSB Min Brg Width Req = 1.5D Min Brg Width Req = -Bearing B Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0
Chords Tens. Comp.
B - C 60 - 102
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - D 3 - 1
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
C - D 41 - 114
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
B2 2'11"8 Common
WEIGHT =15.4
SEQ - 213496
TYPE COMN
5'1"14
2'11"81'4"
4"7
2'4"
2
3'2"
9
8'1"2
LEFT RAKE = 1'7"4
A
B
C
D
812
3X4(A1)
1.5X3
1.5X3
Job:(85661) / -KEENE LUMBER CO /MARK AND KATHY JOHNSON RF / B2 2'11"8 Common This dwg. prepared by the ITW job designer program from truss mfr's layout.Top chord 2x4 SPF #1/#2Bot chord 2x4 SPF #1/#2 Webs 2x4 SPF Stud
90 mph wind, 15.00 ft mean hgt, ASCE 7-05, CLOSED bldg, Locatedanywhere in roof, CAT II, EXP B, wind TC DL=4.2 psf, wind BCDL=6.0 psf.
Wind loads and reactions based on MWFRS with additional C&Cmember design.
Right end vertical not exposed to wind pressure.
In lieu of structural panels or rigid ceiling use purlinsto laterally brace chords as follows: CHORD SPACING(IN OC) START(FT) END(FT) BC 34 0.15 2.96Apply purlins to any chords above or below fillersat 24" OC unless shown otherwise above.
Bottom chord checked for 10.00 psf non-concurrent bottom chord liveload applied per IBC-09 section 1607.
Deflection meets L/360 live and L/240 total load. Creep increasefactor for dead load is 1.50.
Unbalanced snow loads have not been considered.
PLT TYP. WAVEDESC = B2 2'11"8 Common
DESIGN CRIT=IBC 2009 /TPI-2007 FT/RT=3%(0%)/0(0) PLY= 1 QTY= 3 REV. 14.03.01G.0123.00
Maximum Reactions (lbs)Loc R / U / Rw / Rh / RL / W
B 402 / - / 92 / - / 51 / 5.5D 139 / 6 / 36 / - / - / -Wind reactions based on MWFRSB Min Brg Width Req = 1.5D Min Brg Width Req = -Bearing B Fcperp = 565psi.
Maximum Top Chord Forces Per Ply (lbs)Chords Tens.Comp.
A - B 86 0
Chords Tens. Comp.
B - C 60 - 102
Maximum Bot Chord Forces Per Ply (lbs)Chords Tens.Comp.
B - D 3 - 1
Maximum Web Forces Per Ply (lbs)Webs Tens.Comp.
C - D 41 - 114
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERSTrusses require extreme care in fabricating, handling, shipping, installing and bracing. Refer to and follow the latest edition of BCSI (BuildingComponent Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporarybracing per BCSI. Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have a properlyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7, or B10,as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer todrawings 160A-Z for standard plate positions.
ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing,any failure to build the truss in conformancewith ANSI/TPI 1, or for handling, shipping, installation and bracing of trusses.A seal on this drawing or cover page listing this drawing, indicates acceptance of professional engineeringresponsibility solely for the design shown.The suitability and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
TC LL 47.00 PSF
TC DL 7.00 PSF
BC DL 10.00 PSF
BC LL 0.00 PSF
TOT. LD 64.00 PSF
DUR. FAC 1.15
SPACING 24.0 "
JOB #: 85661DATE - 05/04/15
B2 2'11"8 Common
WEIGHT =15.4
SEQ - 213496
TYPE COMN
5'1"14
2'11"81'4"
4"7
2'4"
2
3'2"
9
8'1"2
LEFT RAKE = 1'7"4
A
B
C
D
812
3X4(A1)
1.5X3
1.5X3